Easy fuse selection by family
Fuse selection made simple
LPN-RK-(AMP)SP
LPS-RK-(AMP)SP
LPS-RK-(AMP)SP
LPN-RK-(AMP)SP FRN-R-(AMP)
FRS-R-(AMP)
FRS-R-(AMP)
FRN-R-(AMP)
NOS-(AMP)
NON-(AMP)
NOS-(AMP)
NON-(AMP)
KTS-R-(AMP)
KTS-R-(AMP)
KTN-R-(AMP)
KTN-R-(AMP)
Ultimate protection
CLASS RK1
Advanced protection Advanced protection Basic protection
1
2
3Three tiers of ultimate, advanced and basic protection offers distinct levels of performance benefits.
CLASS RK5 CLASS RK1 CLASS H/K
Ultimate
Basic
Advanced
BUSSMANNSERIESOut-of-stock fuse substitutions and upgrades
Eaton, Bussmann, Fuses Made Simple, Fusetron, Limitron and Low-Peak are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton.
Eaton1000 Eaton BoulevardCleveland, OH 44122United StatesEaton.com
Bussmann Division114 Old State RoadEllisville, MO 63021United StatesEaton.com/bussmannseries
© 2017 EatonAll Rights ReservedPrinted in USAPublication No. 10662March 2017
1. Ultimate protection - Unique dual-element construction delivers a powerful combination of all performance options in one fuse - fast short-circuit protection, current limitation, and time-delay performance with up to 300 kA interrupting ratings.
2. Advanced protection - Choose between fast short-circuit, current limiting performance or energy efficient, current limiting, time-delay performance based on the application. Featuring 200 kA interrupting ratings.
3. Basic protection - Basic single-element protection for service, feeder and branch circuit applications. Featuring up to 100 kA interrupting ratings.
Follow us on social media to get the latest product and support information.
For Eaton’s Bussmann series product information, call 1-855-287-7626 or visit:Eaton.com/bussmannseries
LPJ-(AMP)SP
LPJ-(AMP)SP
JKS-(AMP)
JKS-(AMP)
Ultimate protection
CLASS J
Advanced protection
CLASS J
KRP-C-(AMP)SP
KTU-(AMP)
KLU-(AMP)
Ultimate protection
CLASS L
Advanced protection
CLASS L
LP-CC-(AMP)
FNQ-R-(AMP)*
KTK-R-(AMP)
Ultimate protection
CLASS CC
Advanced protection
CLASS CC
FNQ-(AMP)
KTK-(AMP), KLM-(AMP)***
Supplemental protection
Time-delay
Fast-acting
CONTROL CIRCUIT/SUPPLEMENTAL/MIDGET
*FNQ-R fuses are suggested on primary of control transformers - do NOT upgrade to LP-CC. ** FNA and MIC fuses are pin indication fuses – Suggested upgrades will replace it electrically, but they do not have pin indication.***KLM fuses are rated at 600Vdc. Only use the LP-CC as an upgrade under the following conditions:
• If the application is 300Vdc or less (1/2 – 2-½ A & 20 – 30A)• If the application is 150Vdc or less (2-8/10 – 15A)
Time-delay
Fast-acting
BAF-(AMP)
FNM-(AMP) FNA-(AMP)**
BBS-(AMP) MIC-(AMP)**