ota105102 optix osn 2500 hardware description issue 1.20
TRANSCRIPT
Internal
OTA105102 OptiX OSN 2500 Hardware DescriptionISSUE 1.20
www.huawei.com
HUAWEI TECHNOLOGIES CO., LTD. H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved All rights reserved
Objecti ves
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Conte ntsProduct Introduction Chapter 1Chapter 3 Features
Chapter 1 Product Introduction
Chapter 2 Cabinet, Sub-rack and Boards
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
IntroductionWhat is OSN 2500 ? Full name: OptiX OSN 2500 intelligent optical switching system Forms part of the OptiX OSN NG-SDH Series Optical convergence or access switching system OSN: Optical Switch Node
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Network Application4010G OptiX BWS 1600G 160 10G OptiX BWS 1600G
Long-Haul Back Bone
iManager T200010G/2.5GR
10G OSN 9500/7500
10G/2.5G OSN 9500/7500/3500
Core
OSN 9500/7500/3500
OSN 2500 /1500
OSN 3500/ 2500
OSN 3500/ 2500
Convergence
OSN 1500/Metro
OSN 2500 /Metro
OSN 1500/Metro
Access
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
System ArchitectureSystem architecture of OptiX OSN 2500STM-1 STM-4
LU Cross-connect Unit LU High-order matrix (VC-4) Low-order matrix (VC-12/VC-3)
LU LU
STM-16
PDH Ethernet
TU TU
TU TU
SAN/ Video ATM
External synchronization interface
Timing Unit
Auxiliary Unit
Auxiliary interface
SCC Unit
Management interface
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Large capacity and multi-services accessSTM-1/4/16 VC-4-4c/ 8c/16c Large and multiservices access capacity SDH unit SDH unit STM-1/4/16 VC-4-4c/ 8c/16c
West
East
Cross-connect matrix higher-order (60G) lower-order (20G)Large crossconnect capacity PDH Interface unit Ethernet Interface unit Other Interface unit Multi-granularity cross-connect capacity
E1/T1/E3/T3/E4 H U A W E I T E C H N O LO G I S E C O ., LT D .
FE/GE
ATM 03/12/11
All rights reserved
Conte ntsProduct Introduction Chapter 1Chapter 3 Features
Chapter 1 Product Introduction
Chapter 2 Cabinet, Sub-rack and Boards
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Cabinet
ETSI 300/600 Cabinet (mm) 600 (W) x 300 (D) x 2000 (H) 600 (W) x 600 (D) x 2000 (H) 600 (W) x 300 (D) x 2200 (H) 600 (W) x 600 (D) x 2200 (H) 600 (W) x 300 (D) x 2600 (H) 600 (W) x 600 (D) x 2600 (H)
Weight (kg) 55 79 60 84 70 94
Max. number of mounted sub-racks 2 2 3 3 4 4
H W D
H U A W E I T E C H N O LO G I S E C O ., LT D .
A l g h ts re se rve d lri
03/12/11
Indicators and Power ConsumptionCabinet IndicatorsIndicator Power Critical alarm Major alarm Minor alarm Color Status On Off On Off On Off On Off Description Cabinet is powered ON Cabinet is OFF Critical alarm No critical alarm Major alarm No major alarm Minor alarm No minor alarmPowerCritical MajorMinor
Power distribution unit
Note: Indicators do not flash If alarm indicator is ON, alarm occurs on one or more sub-racks inside the cabinet Alarms occur on sub-racks, ALM cable should be properly connected
Power Fuse capacity/ consumption/ sub- sub-rack (A) rack (W) 400 15
Power Consumption and FuseH U A W E I T E C H N O LO G I S E C O ., LT D . A l g h ts re se rve d lri
03/12/11
Power Distribution Unit1 2 3 4 5 6
1
3 2 OUTPUT
4
ARTN1(+) RTN2(+) NEG1(-) NEG2(-)
BON OFF32A
1
3 2 OUTPUT
4
ON OFF32A 32A 20A 20A
INPUT
32A
20A
20A
1. Power socket (left) 4. Power cable NEG1()
2. Power cable RTN1(+) 5. Power cable NEG2()
3. Power cable RTN2(+) 6. Power socket (right)
A: Supply for Left Power interface B: Supply for Right Power interface H U A W E I T E C H N O LO G I S E C O ., LT D .
From Left, the 1st switch supplies the lower sub-rack The 1st & 2nd switches are mainly for OptiX OSN 7500/3500 A l g h ts re se rve d lri 03/12/11
Conte ntsProduct Introduction Chapter 1Chapter 3 Features
Chapter 1 Product Introduction
Chapter 2 Cabinet, Sub-rack and Boards
H U A W E I T E C H N O LO G I S E C O ., LT D .
A l g h ts re se rve d lri
03/12/11
Sub-rackSEI (Auxiliary Unit)
Service slot area Interface slot area Core Unit SAP (Auxiliary Unit)PIU
FAN UnitDimensions (mm) Weight (kg) 447 (W) x 295 (D) x 472 (H) 17 (not including boards and fans)
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Sub-rackSlot Assignment, Relation & Capacity6 7 1, 2 3, 4S L O T 1 S L O T 2 S L O S S T L L 5 O O T T 2 3 4 . 5 G S L O T 6 2 . 5 G S L O T 7 2 . 5 G S L O T 8 2 . 5 G S L O T 9 2 . 5 G S L O T 1 0 2 . 5 G S L O T 1 1 2 . 5 G S L O T 1 2 2 . 5 G S L O T 1 3 2 . 5 G
12 15, 16 13 17, 18
S L O T 1 4
SS L L OO TT 1 1 5 6
S L O T 1 7
S L O T 1 8
Fiber routing panel SLOT 22 PIU SLOT 23 FAN SLOT 24 FAN SLOT 25 PIU
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Sub-rackSlot access capacityS SSS L L L L O OO O T TT T 1 2 3 4
S L O T 1 9 6 2 2 S M L O T 5 6 2 2 M
S L O T 2 0 6 2 2 S M L O T 6 6 2 2 M
S L O T 2 1 1 . 2 S 5 L G O T 7
S S L L O O T T 9 8 2 2 . . 5 5 G G
S L O T 1 0
S L O T 1 1
S L O T 1 2
S L O T 1 3
S L O T 1 4
sp lit
S L O S SS S T L LL L 5 O OO O TTTT 6 1 23 4 2 2 M
S L O T 6
SSS S L LL L O OO O TTTT 2 6 2 2 2 1 1 11 1 . 2 2 2 . . . . S 5 67 8 5 . . 2 5 5 5 2 A G 5 5 M G G G 5 P G G G
S L O T 7
S L O T 8
S L O T 9
S L O T 1 0
S L O T 1 1
S L O T 1 2
S L O T 1 3
S L O T 1 4
1 . 2 5 Fiber G
2 2 . . 5 5 G G
1 2 . . 2 5 5 G G
S SS S L L L L O OO O T TT T 1 1 1 1 S 5 6 7 8 A P
22 PIU
SLOT 23 FAN
routing panel SLOT 24 FAN
25 PIU
6
2
20 1
22 PIU
Fiber routing panel SLOT 23 SLOT 24 FAN FAN
25 PIU
7
4
21 3All rights reserved 03/12/11
H U A W E I T E C H N O LO G I S E C O ., LT D .
Cont ents Chapter 2 Cabinet, Sub-rack and Boards2.1 SDH unit 2.2 PDH unit 2.3 Ethernet unit 2.4 Core unit 2.5 Auxiliary unit
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Boards
Processing with Interface
Processing
Interface H U A W E I T E C H N O LO G I S E C O ., LT D . A l g h ts re se rve d lri 03/12/11
SDH UnitBoard Full name Slots Available Module available Connector typeLC
SF16
1 x STM-16 processing with optical interface board (FEC) optical interface board
7, 8, 11 ~ 13
Fixed wavelength output Ve-16.2c, Ve-16.2d, Ve-16.2f Fixed wavelength output, I-16, S-16.1, L-16.1, L-16.2, L-16.2Je, V-16.2Je (with BA), U-16.2Je (with BA and PA) I-1, S-1.1, L-1.1, L-1.2, Ve-1.2 I-4, S-4.1, L-4.1, L-4.2, Ve-4.2
SL16 (A) 1 x STM-16 processing with SLQ41 SLD4 SL44 x STM-4/1 processing with optical interface board 2 x STM-4 processing with optical interface board 1 x STM-4 processing with optical interface board 5 ~ 8, 11 ~ 13
Signal processing with optical interface board H U A W E I T E C H N O LO G I S E C O ., LT D . A l g h ts re se rve d lri 03/12/11
SDH UnitCLASS 1 LASER PRODUCT
4 indicators 4 indicators
LC Connector LC Connector
Indicator STAT ACT Board Board Status Activation
Status On, green Off red
On, green Off
Color
Description normally. Board works hardware fails. is powered off.
Board is activated/configured. not activated/configured.
H U A W E I T E C H N O LO G I S E C O ., LT D .
A l g h ts re se rve d lri
03/12/11
SDH UnitIndicator descriptionIndicator PROG Board Software Status On, green Color Description Upload of board software to FLASH or the FPGA upload is normal, or the board software initialization is normal. Board software is being uploaded to FLASH or FGPA. Board software is initializing, and is in BIOS boot stage. Board software in FLASH or the FPGA configuration is lost, resulting in upload and initialization failure. No power supply. Service is normal and no service alarm occurs. Critical or major alarm occurs to service. Minor or remote alarm occurs to service. No service configured or no power supply.
On for 100ms and off for 100ms alternatively, green On for 300ms and off for 300ms alternatively, green On, red Off
SRV Service Alarm
On, green On, red On, yellow Off
H U A W E I T E C H N O LO G I S E C O ., LT D .
A l g h ts re se rve d lri
03/12/11
SDH Unit
SFP Module SFP Module
CLASS 1 LASER PRODUCT
L SL16 S S L16AH U A W E I T E C H N O LO G I S E C O ., LT D . A l g h ts re se rve d lri 03/12/11
SDH UnitFunctions of SL16Collect Alarm and performanceCC to S d Sen
Send to Cross-connect unit
STM-16
a OH
Und A
SD H Un ing cess it pro16 X VC4PTR
H U A W E I T E C H N O LO G I S E C O ., LT D .
SDH Unit
03/12/11
All rights reserved
SDH UnitFeatures of SL16
1 Last six digits of BOM 2 Internal number 3 Board version 4 Board name 5 Board characteristic number
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
SDH UnitOptical port parameters of SL16Optical interface type (Board characteristic #) Wavelength (nm) Distance (km) I-16 (01) S-16.1 (02) 1310 1310 02 2 15 L-16.1 (03) 1310 15 40 L-16.2 (04) 1550 40 80 L-16.2Je (02) 1550 80 100 V-16.2Je (BA) (03) 1550 80 140 U-16.2Je (BA+PA) 1550.12 (04) 140 170
Launched power (dBm) Receiver sensitivity (dBm)
-10~-3 -18
-5~0 -18
-2~3 -27
-2~3 -28
5~7 -28
14 -28
17 -34
Receiver overload (dBm)
-3
0
-9
-9
-9
-9
-10
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
SDH UnitCommon alarms of SDH unitAlarm level Color Critical Minor Major Alarm name R_LOS POWER_ MS_AIS MS_RDI AU_AIS ABNORMAL HP_RDI LOOP_ALM Alarm reason Receiver can not receive STM-N signal normally. Power alarm e.g. R_LOS happens. Faulty service configuration Wrong module ofreceives the R_LOS, CriticalSDH boardthe line board fails. R_LOF or Opposite station MS_AIS signal at the opposite node or transmitter at the Faulty receiver local node Opposite node receives such alarms as AU_AIS and AU_LOP. Faulty receiver at the opposite node or transmitter at the local node Software inloop or outloop is being performed.
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
SDH UnitCommon performance events of SDH unit Performance name Performance meaningRSBBE MSBBE MSFEBBE HPBBE HPFEBBE AUPJCHIGH AUPJCLOW RPLCUR RPLMAX RPLMIN TPLCUR TPLMAX TPLMIN Regenerator section block of background error Multiplex section block of background error Multiplex section far end block of background error High-order path block of background error High-order path far end block of background error Count of positive AU pointer justifications Count of negative AU pointer justifications Current value of input optical power Maximum value of input optical power Minimum value of input optical power Current value of output optical power Maximum value of output optical power Minimum value of output optical power
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
SDH UnitBoard R1SLQ1 R1SL4 R1SLD4 R1SL1 Full name Slots availableModule available Connector 4 STM-1 STM-4 processing with 2 x STM-4 processing with 7,~ 7,19 ~ 21 I-4, S-4.1, L-4.1, L-4.2, Ve- LC STM-1 5 21 I-1, S-1.1, L-1.1, L-1.2, type optical interface board 1.2 4.2
Signal processing with optical interface board H U A W E I T E C H N O LO G I S E C O ., LT D . All rights reserved 03/12/11
SDH Unit
SFP Module SFP Module
CLASS 1 LASER PRODUCT
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Cont ents Chapter 2 Cabinet, Sub-rack and Boards2.1 SDH unit 2.2 PDH unit 2.3 Ethernet unit 2.4 Core unit 2.5 Auxiliary unit
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
PDH UnitC34S D34S MU04 PL3A PL3 PD3 SPQ4 Board 3 6 E4/STM-1e signalwith 4 x E4/STM-1 processingelectrical FullE3/T3 processing boardboardand namesignal access bridging access board switching board interface board 1, 3, 15, ~ 5 7, 12, 17 6,~ 8, 1113 13 Slots available SMB Connector type
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
PDH Unit
SMB connector SMB connector Indicators Indicators
PP 3 D LP 3H U A W E I T E C H N O LO G I S E C O ., LT D . All rights reserved 03/12/11
PDH Unit
Board PQM PQ1 PD1 D75S D12S D12B
Full name 63 x E1/T1 signal processing board 63 x E1 signal processing board 32 x E1/T1 signal processing board 32 x 75 E1 signal access bridging and switching board 32 x 120 E1/100 T1 signal access bridging and switching board 32 x 120 E1/100 T1 signal access bridging board
Slots available Connector type 5 ~ 7, 12, 13 -
5 ~ 7, 19 ~ 21 1 ~ 4, 15 ~ 18 DB44
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
PDH Unit
Indicators Indicators
DB44 DB44
PQ1 D75 PQM DH U A W E I T E C H N O LO G I S E C O ., LT D . All rights reserved 03/12/11
PDH UnitFunctions of PQ1Collect Alarm and performanceCC to S d Sen
Send to Cross-connect unit
63 X E1
H LPO
a
-P T d TU n
PD H Un ing cess it pro1VC4R
H U A W E I T E C H N O LO G I S E C O ., LT D .
PDH Unit
All rights reserved
03/12/11
PDH UnitFeatures of PQ1
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
PDH UnitCommon alarms of PDH unitAlarm level Color Major Alarm name ALM_SUBCARD_ABN T_ALOS TU_AIS Alarm reason The interface board and the processing board are mismatched No E1 service is accessed Critical alarm e.g. R-LOS happens Wrong service configuration Faulty PDH board Minor LP_RDI LP_REI Opposite node receives such alarms as TU_AIS and TU_LOP LPBBE happens on the opposite node
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
PDH UnitCommon performance of PDH unitPerformance name LPBBE LPFEBBE LPES LPFEES TUPJCHIGH TUPJCLOW Performance meaning Low-order path block of background error Low-order path far end block of background error Low-order path errored second Low-order path far end errored second Count of positive TU pointer justifications Count of negative TU pointer justifications
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Cont ents Chapter 2 Cabinet, Sub-rack and Boards2.1 SDH unit 2.2 PDH unit 2.3 Ethernet unit 2.4 Core unit 2.5 Auxiliary unit
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Ethernet UnitBoard EGS4 EGS2 EGT2 EMS4 Full name Slots available 4 x GE with L2 switching 5 ~ 8, 11 ~ 13 processing with interface board with L2 switching 2 x GE processing with interface board transparent 2 x GE transmission processing with interface board L2 4 GE + 16 x FE with switching processing with interface board Interface type 1000BASE-SX/LX/ZX 1000BASE-SX/LX/ZX 1000BASE-SX/LX/ZX 1000BASE-SX/LX/ZX, 100Base-FX (From interface board) Connector LC type LC LC RJ-45, LC
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Ethernet UnitCLASS 1 LASER PRODUCT
SFP Module SFP Module Indicator LINK1 Color Status On Description Link is established
Off
Link is not established
ACT1
Flashing
Data exchanged
Off
No data being exchanged
E EGS03/12/11
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
Ethernet UnitBoard EFS4 EFS0 EFT8 EFT4 ETF8 ETS8 EFF8 Full name Slots available Interface type 10Base-T/ 100Base-TX 10Base-T/ 10Base-T/ 100Base-TX 10Base-T/ 100Base-TX 10Base-T/ 100Base-TX 100Mbit/s-FX 100Base-TX Connector type RJ-45 RJ-45 RJ-45 RJ-45 RJ-45 LC 4 x FE with L2 switching 5 ~ 8, 11 ~ 13 8 x FE with with interface L2 switching 6, 7, 12, 13 processing transparent 8 (16) x FE board 7, 12, 13 processing board transparent 4 x FE ~ transmission processing with 5 ~ 7, 1917 21 8 x FE twisted pair signalwith (5 3, 8, 11 ~ 13) 1, ~ 15, transmission processing interface boardpair signal 8 x FE twisted access optical signal access interface board board 8 x FE board access switching board
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Ethernet Unit
LC connector LC connector RJ 45 connector RJ 45 connector
EFS4EFT8 EFS0 ETCLASS 1 LASER PRODUCT
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Ethernet UnitBoard EGR2 Full name 2 x GE RPR processing with interface board Slots available Interface type 6, 7, 12, 13 Connector type 1000Mbit/s-SX/LX LC
EMR0
1 GE + 4 (12) x FE 5 ~ 8, 11 ~ 13 RPR processing with interface board
10/100Mbit/s-TX, RJ-45, LC 1000Mbit/s-SX/LX
l
Function EVPL/EVPLAN Service QoS Resilient Packet Ring Function Weighted fair algorithm and three service levels Auto discovery of topology Wrap and steering protection
GE PORT GE PORT SFP Module SFP Module FE PORT FE PORT RJ 45 connector RJ 45 connector 03/12/11
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
Ethernet UnitFunction of EFS4Collect Alarm and performanceto end S C SC
Send to Cross-connect unit
FE
GFP
4 X FE
VC12, VC3,
VC-12-Xv(x63), VC-3-Xv(x12)
H U A W E I T E C H N O LO G I S E C O ., LT D .
Et he rn et Un
8 X VC4
Eth ern et Unit
All rights reserved
03/12/11
Ethernet UnitFeatures of EFS4
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Ethernet UnitCommon alarms of Ethernet unitAlarm level Critical Major Color Alarm name HARD_BAD ETH_LOS TU_AIS_VC3 PROTOCOL_MM Minor LP_RDI_VC3 LCAS_BAND_ DECREASED Alarm reason Faulty board hardware Interrupted Ethernet link Interrupted contiguous VC3-xc Mismatched encapsulation protocol TU_AIS_VC3 happens in the opposite node VC-Trunk bandwidth decreases
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Ethernet UnitCommon performance events of Ethernet unitPerformance name DropOv DropUd RxBadOctOv RxBadOctUd TxBadOctOv TxBadOctUd ColOv ColUd Performance meaning Number of packet losses is over upper alarm threshold Number of packet losses is under lower alarm Number of the bytes of bad packets received is over threshold Number of the bytes of bad packets received is under upper alarm threshold Number of the bytes of bad packets transmitted is lower alarm threshold Number of the bytes of bad packets transmitted is over upper alarm threshold Number of detected conflicts is over upper alarm under lower alarm threshold Number of detected conflicts is under lower alarm threshold threshold
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Cont ents Chapter 2 Cabinet, Sub-rack and Boards2.1 SDH unit 2.2 Ethernet unit 2.3 Ethernet unit 2.4 Core unit 2.5 Auxiliary unit
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Core UnitlFunctionCross-connect Unit Timing Unit SCC Unit Line unit Low-order Line unit cross-connect Connector (Interface) type capacity
Board name
Slot available
High-order cross-connect capacity 60G
CXLLN
9, 10
20G
STM-16 SFP STM-4 SFP L-16.1, L-16.2 I-16, S-16.1,
S-4.1, L-4.1, L-4.2, Ve-4.2STM-1 SFP
S-1.1, L-1.1, L-1.2, Ve-1.2
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Cross-Connect UnitSDH unit PDH unit Ethernet unitCollect Alarm and performanced to Sen C SC
High-order cross-connect matrix (60G)
Low-order crossconnect matrix (20G)Flexible service cross-connect, loopback, multicast and broadcast
Multi-Granularity: VC12/VC3/VC4/VC-4-xc
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Cross-Connect Unit2.5G line unit 2.5G line unit
2.5G line unit
CrossconnectPDH unit
Crossconnect Standby
2.5G line unit
Active
PDH unit
Ethernet unit
Ethernet unit
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Cross-Connect UnitIndicator STAT Color Description Board works normally Board hardware fails Board is powered off ACTX Cross-connect unit is in active status Cross-connect unit is in standby status
CXL16 CXL4 CXL1Logical unit GXCL (5G) EXCL (20G)H U A W E I T E C H N O LO G I S E C O ., LT D .
STAT STATAll rights reserved
03/12/11
Timing UnitlFunction Process 2 x 2048 kHz or 2048 kbit/s external timing signals Supply 2 x 2048 kHz or 2048 kbit/s timing signals Process SSM protocol Non-synchronization status message (SSM) mode Standard SSM mode for clock signal quality Extended SSM mode for clock ID
Indicator SYNC
Color Description Clock works in Normal mode Clock works in hold-over or free-run mode
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Cross-Connection and Timing UnitCommon alarms of Cross-Connect and Timing unitAlarm level Critical Major Color Alarm name BUS_ERR APS_INDI TEMP_OVER W_OFFLINE Minor EXT_SYNC_LOS Alarm reason Chip of the cross-connect board is damaged Damaged backplane bus MSP switching happens Ambient temperature is too high. Ejector lever on the front panel is rotated to the open position. interface signal of the external clock source Physical is lost. CLOCK_ENTER_NO_ Clock working mode changes from locked into TRACE_MODE holdover or free-run. Warning APS_FAIL SWITCH_DISABLE OTH_BD_STATUS Multiplex section protection switching fails. MS node information is lost or set incorrectly Board switching is disabled Another board pulled out or plugged in
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
System Control & Communication Unit
SDH unit
PDH unit Other unit Cross-connect unit
Collect Alarm and performance
SC C Un it
Commands
SCC Unit
NMS
DCC
Other NE All rights reserved
H U A W E I T E C H N O LO G I S E C O ., LT D .
03/12/11
System Control & Communication Unit Active SCC unit ACTC Standby SCC unit ACTC To warm reset board, press RESETReset board Reset board
( (
) )
To cut buzzer temporarily, press ALMC for 1 second ( To cut buzzer permanently, press ALMC for 3 seconds To re-enable buzzer, press ALMC for 1 second (
) ( ) )
Alarm cut Alarm cut switch (short switch (short and long and long press) press)
Logical unit SCC GSCC (with ASON)
CXL103/12/11
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
System Control & Communication UnitFunctions of SCC unit
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
System Control & Communication Unit
NMS
Ring A
Ring B
Ethernet port
L< 50m
Ethernet port
Extended ECC function
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
System Control & Communication UnitFour databases on the SCCIssued dataMDB Automatically saves the current data in dynamic RAM. If power fails, the data in MDB will be lost.
MDB
DRDB Automatically saves the successfully verified data. If power fails, the data in DRDB will be lost.
verifySuccess
Fail
NE in installing status
FDB0, FDB1 Manually or periodically saves the data. Enduringly saves data and does not need battery.
DRDBSave manually or periodically every 30 mins
Boards in running status
FDB0 FDB1All rights reserved 03/12/11
H U A W E I T E C H N O LO G I S E C O ., LT D .
System Control & Communication UnitCommon alarms of SCC unitAlarm level Critical Major Color Alarm name NESTATE_INSTALL MSSW_DIFFERENT WRG_BD_TYPE NESF_LOST POWER_ABNORMAL Alarm reason NE is in the installing state. Software in the master and slave SCC are mismatched Inserted board and the configured board are mismatched Host software is lost. Faulty power resource, e.g. the 3.3V power module of the SCC or AUX, and the 3.3V backup power module, and 2 channels of 48V Too low battery voltage on the SCC
POWER_FAIL
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Line Unitl STM-1 S-1.1, L-1.1, L-1.2, Ve-1.2 l STM-4 S-4.1, L-4.1, L-4.2 and Ve-4.2 l STM-16 I-16, S-16.1, L-16.1 and L-16.2 l Automatic laser shutdown (ALS) function l Swappable optical module (SFP) l Support VC-4-4c, VC-4-8C and AU-4-16c services l Inloop and outloop functionH U A W E I T E C H N O LO G I S E C O ., LT D .
CXL16 CXL4 CXL1STAT STATAll rights reserved 03/12/11
Cont ents Chapter 2 Cabinet, Sub-rack and Boards2.1 SDH unit 2.2 PDH unit 2.3 Ethernet unit 2.4 Core unit 2.5 Auxiliary unit
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Auxiliary Unit
Board
System Auxiliary Process System Extended Interface Power Interface Board Booster Amplifier Board Pre-amplifier Board Fan unit Uninterruptible Power Modules
Board name
SAP SEI PIU
BA2 BPA FAN UPM
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
System Auxiliary Process unit SAPl
Function
QS P 1 ASA T T P O R G P R W A P R W B P R W C
CM O
COM test portEH T
NM portQS P 1 A
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
System Extended Interface unit SEIALMO1/2: Alarm output ALMI1/2: 8 x Environment alarm input LAMP1/2: Cabinet indicator output OAM: X.25 OAM F1: Co-directional data 64 Kbit/s S1 ~ S4: Serial 1 ~ 4 broadcast data F&f: LCT PHONE: Orderwire CLK1/2: 120 Ext clock input/output 1/2 V1/2: NNI Audio/Signaling
CLKO1/2: 75 Ext clock output 1/2 CLKI1/2: 75 Ext clock input 1/2
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Power Interface Board PIU
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Power Interface Board PIUInterface PWS PWR Description 50 W power output interface, supplying power for COA or HUB 48 V power access interface
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
FAN Unit
FAN Unit
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
FAN Unit
Indicator STAT
Color
Description The fan operates normally. The fan, fan power board or FANA is abnormal. The fan is turned off due to low temperature.
Alarm levelMajor
Color
Alarm nameFAN_FAIL
Alarm reasonThe faulty fan The fan is power off
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Questions
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
SummaryUnit Constituent board Function Access and process STM-N signals and concatenated optical signals. Implement TPS protection. SDH unit Processing with optical SL16, SLQ4, SLD4, R1SLD4, interface board SL4, R1SL4, SLT1, SLQ1, R1SLQ1, SL1, R1SL1, SEP1 Interface board EU08, OU08, EU04 Protection switching PDH unit Processing with board electrical interface Interface board board board
TSB8 SPQ4, PD3, PL3, PQ1, PQM, Access and process E1, E1/T1, PD1 E3/T3, E4/STM-1 electrical signals. MU04, D34S, C34S, D75S, D12S,Implement TPS protection. D12B EGS2, EGT2, EMS4, EFS0, EFS4, EFT8, EFT4 ETF8, EFF8, ETS8 Access and process FE, GE signals. Implement TPS protection
Ethernet unit
Processing with optical/electrical Interface board Interface/ Processing board
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
SummaryUnit Ethernet Processing with interface Interface board Interface board unit (RPR) ATM interface unit WDM unit Core unit Constituent board EMR0, EGR2 ETF8, EFF8, ETS8 ADL4, ADQ1, IDQ1, IDL4 MR2A, MR2B, MR2C LWX Function Access and process FE, GE signals. Support RPR and conduct TPS protection for Ethernet signals. and process STM-4, STM-1 ATM signal. Access Implement TPS protection.
Provide add/drop multiplexing of any two adjacent wavelengths. Implement conversion between client signaling wavelengths of any rate (10 Mbit/s to 2.7 Gbit/s CXL1, CXL4, CXL16 Implement signal)connection wavelengthsthe NRZ code cross and those and provide equipment with G.692 standard. complying with system clock. Provide interface for connecting the equipment with the NM system and process the overhead of SDH signals. Support intelligent feature. Provides the optical interface.
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
SummaryUnit Power input unit Constituent board PIU Function
Provide power supply and protect the equipment against abnormal power Inter-board communication and SEI power backup unit Implement centralized power backup function and provide auxiliary interfaces externally (F1, alarm and external clock) Fan unit FAN Dissipate heat for the system Amplify or pre-amplify the optical power Amplify the optical power and installed in the cabinet Other Optical booster BA2, BPA functional amplifier board Case-based optical 61COA and units amplifier 62COA
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Conte ntsProduct Introduction Chapter 1Chapter 3 Features
Chapter 1 Product Introduction
Chapter 2 Cabinet, Sub-rack and Boards
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Equipment ProtectionS L O T 1 S L O T 2 S L O T 3 S L O T 4 S L O T 5 S L O T 6 S L O T 7 S L O T 8 S L O T 9 C X L P W W W W S L O T 10 C X L S L O T 1 1 S L O T 1 2 S L O T 1 3 S L O T 1 4 S A P S L O T 1 5 S L O T 1 6 S L O T 1 7 S L O T 1 8
1:4 TPS of E1/T1 board
S L O T 1
S L O T 2
S L O T 3 T S B
S L O T 4
S L O T 5
S L O T 6
S L O T 7
S L O T 8
S L O T 9 C X L
S L O T 10 C X L
S L O T 1 1
S L O T 1 2
S L O T 1 3
S L O T 1 4 S A P
S L O T 1 5
S L O T 1 6
S L O T 1 7 T S B
S L O T 1 8
P
W
W P
2 groups 1:1 TPS for E3/T3/E4/STM-1(e)/FE boardH U A W E I T E C H N O LO G I S E C O ., LT D . All rights reserved 03/12/11
Equipment ProtectionItems protected E1/T1 processing card E3/T3 processing card E4/STM-1 processing card FE processing board Core unit -48V power interface card 3.3V card power supply Protection scheme 1:N (N 4) TPS 1:1 TPS (2 Groups) 1:1 TPS (2 Groups) 1:1 TPS (2 Groups) 1+1 hot backup protection 1+1 hot backup protection 1:N centralized hot backup protection
* The OptiX OSN 2500 can support two TPS groups of different types of services at the one time.
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Equipment Protection
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Network Level ProtectionsProtections Linear MSP MSP ring Types 1+1 MSP 1:N (1 N 14) MSP 2-fiber bidirectional MSP ring 2-fiber unidirectional MSP ring 4-fiber bidirectional MSP ring Mesh Protection SNCP Dual node interconnection (DNI) Fiber-Shared Virtual Path Protection MS-Shared Optical Path Protection RPR VP-Ring/VC-Ring Protection Intelligent function
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Intelligent Features
Resilient Packet Ring (RPR)lTopology automatic discovery function lFair algorithm l3 service levels
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Summaryl
H U A W E I T E C H N O LO G I S E C O ., LT D .
All rights reserved
03/12/11
Thank Youwww.huawei.com