osram p-vip

57
P-VIP Replacement Lamps, Subject to alteration Page: 1 DO DIS P-VIP Replacement Lamps

Upload: marius-iggy

Post on 16-Sep-2015

390 views

Category:

Documents


11 download

DESCRIPTION

OSRAM P-VIP

TRANSCRIPT

  • P-VIP Replacement Lamps,Subject to alteration Page: 1

    DO DIS

    P-VIP Replacement Lamps

  • P-VIP Replacement Lamps,Subject to alteration Page: 2

    DO DIS

    P-VIP and VIP after sales lampsGeneral description New after sales lamps Existing after sales lamps Instruction for use

    P-VIP Replacement Lamps Agenda

  • P-VIP Replacement Lamps,Subject to alteration Page: 3

    DO DIS

    P-VIP MD TV Replacement Lamps

    482 47E01HM4008321 126 64150TVP-VIP 120-132/1.0 E22ha

    542 959 002G4008321 24428450TVP-VIP 132-150/1.0 E23ha542 94D 002G4008321 24426050TVP-VIP 132-150/1.0 E22ha

    535 05B 002G4008321 221 56850TVP-VIP 100-120/1.0 E23ha 535 073 002G4008321 221 58250TVP-VIP 100-120/1.0 E22ha

    541 559 01874008321 24361450TVP-VIP 100-120/1.3 P23a

    542 930 002G4008321 90132350TVP-VIP 100-120/1.3 E23a

    518 63B 002G4008321 194 94750TVP-VIP 120-132/1.0 P22ha518 62F 002G4008321 194 92350TVP-VIP 100-120/1.0 P22ha518 59A 002G4008321 194 90950TVP-VIP 100-120/1.3 E23ha

    ICEAN 10 (1pcs)

    Box size, pcs.Cat.Lamp type

  • P-VIP Replacement Lamps,Subject to alteration Page: 4

    DO DIS

    P-VIP FP Replacement Lamps

    518 71D 002G4008321 195 10460FPP-VIP 200/1.0 E19a544 77A 002G4008321 24223560FPP-VIP 200/1.0 E17.5a

    A54256C002G4008321 257 29150FPP-VIP 250/1.3 E21.8a

    518 688 002G4008321 195 04350FPP-VIP 200/1.0 P21.5a518 700 002G4008321 195 08150FPP-VIP 180/1.0 E20a518 67C 002G4008321 195 02950FPVIP R 150/P22a518 647 002G4008321 194 96150FPP-VIP 150/1.3 E21.5a518 661 002G4008321 195 00550FPVIP R 150/P16a518 653 002G4008321 194 98550FPVIP R 120/P16a518 694 002G4008321 195 06760FPVIP R 120/P12a538 118 002G4008321 22866650FPP-VIP 150/1.0 P21.5a

    ICEAN 10 (1pcs)

    Box size, pcs.Cat.Lamp type

  • P-VIP Replacement Lamps,Subject to alteration Page: 5

    DO DIS

    P-VIP and VIP after sales lampsGeneral descriptionNew after sales lamps Existing after sales lamps Instruction for use

    P-VIP Replacement Lamps Agenda

  • P-VIP Replacement Lamps,Subject to alteration Page: 6

    DO DIS

    Supreme efficiency P-VIP and VIP lampsHighest quality meeting the strict quality demands of the CE and IT industries

    From leading player in the market

    P-VIP Replacement Lamps Advantages

  • P-VIP Replacement Lamps,Subject to alteration Page: 7

    DO DIS

    Technology Discharge lamps with Mercury-halogen gasLamp power 100 250 W ACLumen yield > 60 lm / WPressure cold lamp: 100 mbar

    hot lamp: up to 250 barBurner temperature operating: up to 1200 C

    typical cool down < 5 min.Pre-materials

    Burner Glass: ultra pure quartz glassElectrodes: Tungsten

    Reflector Glass, coated with dichroic mirror

    a) Valid for P-VIP and VIP R lamps

    P-VIP Technical Aspects

  • P-VIP Replacement Lamps,Subject to alteration Page: 8

    DO DIS

    P-VIP 150/1.3 E21.5ha

    ProfessionalVideo Projection high performance discharge lamp

    Lamp power

    Electrode gapReflector shapeElliptical or Parabolic

    Reflector size

    Extra Infoh: 15 kV ignition

    Aftermarket

    P-VIP Lamp Naming

  • P-VIP Replacement Lamps,Subject to alteration Page: 9

    DO DIS

    VIP R 150 / P16aVideo Projection high performance discharge lamp

    Lamp power Reflector shapeand size

    After market

    Reflector

    P-VIP Lamp Naming

  • P-VIP Replacement Lamps,Subject to alteration Page: 10

    DO DIS

    P-VIP and VIP after sales lampsGeneral description New after sales lampsExisting after sales lamps Instruction for use

    P-VIP Replacement Lamps Agenda

  • P-VIP Replacement Lamps,Subject to alteration Page: 11

    DO DIS

    Lamp P-VIP 120-132/1.0 E22ha

    Category MD TV Reflector E22 elliptic Arc gap 1.0 mm Power range 120 132 W Ignition 15 18 kV Light output typ.a 5,900 lm @ 132 W Average Life timeb > 6,000 h @ 132 W Environmental Complies RoHS

    a) observed in working distance through 6 mm apertureb) when operated on OSRAM lamp driver PT VIP 01 RP

  • P-VIP Replacement Lamps,Subject to alteration Page: 12

    DO DIS

    Lamp P-VIP 120-132/1.0 E22ha

    04:00 oclocklocation contact 2acentral at baselocation contact 1atooled air gapsair inletsborosilicateReflector glassyesfront glass34.0 mmworking distance

    Lamp designE22 ellipticContour

    < 85.0

    F2

    34.0

    70

    Top

    65

    A

    A

    A = reference edgeDimensions in mm

    View from Rear

    Glass air guidesnot to scale

    30

  • P-VIP Replacement Lamps,Subject to alteration Page: 13

    DO DIS

    Lamp P-VIP 100-120/1.3 E23a

    Category MD TV Reflector E23 elliptic Arc gap 1.3 mm Power range 100 120 W Ignition 5 7 kV Light output typ.a 5,200 lm @ 120 W Average Life timeb > 6,000 h @ 120 W Environmental Complies RoHS

    a) observed in working distance through 6 mm apertureb) when operated on OSRAM lamp driver PT VIP 2AC/380 O1

  • P-VIP Replacement Lamps,Subject to alteration Page: 14

    DO DIS

    Lamp P-VIP 100-120/1.3 E23a

    dimensions in mm

    03:00 oclocklocation contact 2a

    a) viewed from front

    central at baselocation contact 1ano, lamp closedair inletsborosilicateReflector glassyesfront glass52.0 mmworking distance

    Lamp designE23 ellipticContour

    < 88.0

    front view

    95.0 F2

    52.0

    top

  • P-VIP Replacement Lamps,Subject to alteration Page: 15

    DO DIS

    Lamp P-VIP 132-150/1.0 E22ha

    Category MD TV Reflector E22 elliptic Arc gap 1.0 mm Power range 132 150 W Ignition 15 18 kV Light output typ.a 6,500 lm @ 150 W Average Life timeb 6,000 h @ 150 W Environmental Complies RoHS

    a) observed in working distance through 6 mm apertureb) when operated on OSRAM lamp driver PT VIP 01 RP

  • P-VIP Replacement Lamps,Subject to alteration Page: 16

    DO DIS

    04:00 oclocklocation contact 2acentral at baselocation contact 1atooled air gapsair inletsborosilicateReflector glassyesfront glass34.0 mmworking distance

    Lamp designE22 ellipticContour

    < 85.0

    F2

    34.0

    70

    Top

    65

    A

    A

    A = reference edgeDimensions in mm

    View from Rear

    Glass air guidesnot to scale

    30

    Lamp P-VIP 132-150/1.0 E22ha

  • P-VIP Replacement Lamps,Subject to alteration Page: 17

    DO DIS

    Lamp P-VIP 132-150/1.0 E23ha

    Category MD TV Reflector E23 elliptic Arc gap 1.0 mm Power range 132 150 W Ignition 15 18 kV Light output typ.a 6,500 lm @ 150 W Average Life timeb 6,000 h @ 150 W Environmental Complies RoHS

    a) observed in working distance through 6 mm apertureb) when operated on OSRAM lamp driver PT VIP O1RP

  • P-VIP Replacement Lamps,Subject to alteration Page: 18

    DO DIS

    Lamp P-VIP 100-120/1.0 E23ha

    dimensions in mm

    03:00 oclocklocation contact 2a

    a) viewed from front

    central at baselocation contact 1ano, lamp closedair inletsborosilicateReflector glassyesfront glass52.0 mmworking distance

    Lamp designE23 ellipticContour

    < 88.0

    front view

    95.0 F2

    52.0

    top

  • P-VIP Replacement Lamps,Subject to alteration Page: 19

    DO DIS

    Lamp P-VIP 100-120/1.3 P23a

    Category MD TV Reflector P23 parabolic Arc gap 1.3 mm Power range 100 120 W Ignition 15 18 kV Light output typ.a 4,400 lm @ 120 W Average Life timeb 6,000 h @ 120 W Environmental Complies RoHS

    a) observed in 900 mm distance through 95 mm apertureb) when operated on OSRAM lamp driver PT VIP 2AC/380 O1

  • P-VIP Replacement Lamps,Subject to alteration Page: 20

    DO DIS

    Lamp P-VIP 100-120/1.3 P23a

    dimensions in mm

    04:30 oclocklocation contact 2a

    a) viewed from front

    central at baselocation contact 1anoair inletsborosilicateReflector glassyesfront glassinfiniteworking distance

    Lamp designP23 parabolicContour

    < 82.0

    topfront view

    Max

    . 96

    .0

    < 92.0

  • P-VIP Replacement Lamps,Subject to alteration Page: 21

    DO DIS

    Lamp P-VIP 200/1.0 E17.5a

    Category FP Reflector E17.5 elliptic Arc gap 1.0 mm Rated power 200 W Ignition 16 kV Light output typ.a 6,300 lm @ 200 W Average Life timeb 2,000 h @ 200 W Environmental Complies RoHS

    a) observed in working distance through 5.0 x 3.8 mm2 rectangularaperture

    b) when operated on OSRAM lamp driver PT VIP 3 AC/380 O3

  • P-VIP Replacement Lamps,Subject to alteration Page: 22

    DO DIS

    dimensions in mm

    10:30 oclocklocation contact 2a

    a) viewed from front

    Side at baselocation contact 1anoair inletsaborosilicateReflector glassnofront glass39.15 mmworking distance

    Lamp designE17.5 ellipticContour

    < 52,0

    F2

    48.0

    43.0

    front view

    top

    Lamp P-VIP 200/1.0 E17.5a

    39,15

  • P-VIP Replacement Lamps,Subject to alteration Page: 23

    DO DIS

    Lamp P-VIP 250/1.3 E21.8a

    Category FP Reflector E21.8 elliptical Arc gap 1.3 mm Rated power 250 W Ignition 5 kV Light output typ.a 8.600 lm @ 250 W Average Life timeb > 2,000 h @ 250 W Environmental Complies RoHS

    a) observed in working distance through 5.0 x 3.8 mm2 rectangular apertureb) when operated on OSRAM lamp driver PT VIP 5AC/380 O4

  • P-VIP Replacement Lamps,Subject to alteration Page: 24

    DO DIS

    Lamp P-VIP 250/1.3 E21.8a

    04:00 oclocklocation contact 2acentral at baselocation contact 1a67 mmLamp lenghtair gapsair inletsCristalizedReflector glassyesfront glass36.0 mmworking distance

    Lamp designE21.82 ellipticalContour

    61 6

  • P-VIP Replacement Lamps,Subject to alteration Page: 25

    DO DIS

    P-VIP and VIP after sales lampsGeneral description New after sales lamps Existing after sales lampsInstruction for use

    P-VIP Replacement Lamps Agenda

  • P-VIP Replacement Lamps,Subject to alteration Page: 26

    DO DIS

    Lamp P-VIP 100-120/1.0 E23ha

    Category MD TV Reflector E23 elliptic Arc gap 1.3 mm Power range 100 120 W Ignition 15 18 kV Light output typ.a 5,200 lm @ 120 W Average Life timeb > 6,000 h @ 120 W Environmental Complies RoHS

    a) observed in working distance through 6 mm apertureb) when operated on OSRAM lamp driver PT VIP 2AC/380 O1

  • P-VIP Replacement Lamps,Subject to alteration Page: 27

    DO DIS

    Lamp P-VIP 100-120/1.0 E23ha

    dimensions in mm

    03:00 oclocklocation contact 2a

    a) viewed from front

    central at baselocation contact 1ano, lamp closedair inletsborosilicateReflector glassyesfront glass52.0 mmworking distance

    Lamp designE23 ellipticContour

    < 88.0

    front view

    95.0 F2

    52.0

    top

  • P-VIP Replacement Lamps,Subject to alteration Page: 28

    DO DIS

    Lamp P-VIP 100-120/1.0 E22ha

    Category MD TV Reflector E22 elliptic Arc gap 1.0 mm Power range 100 120 W Ignition 15 18 kV Light output typ.a 5,200 lm @ 120 W Average Life timeb > 6,000 h @ 120 W Environmental Complies RoHS

    a) observed in working distance through 6 mm apertureb) when operated on OSRAM lamp driver PT VIP 01 RP

  • P-VIP Replacement Lamps,Subject to alteration Page: 29

    DO DIS

    Lamp P-VIP 100-120/1.0 E22ha

    04:00 oclocklocation contact 2acentral at baselocation contact 1atooled air gapsair inletsborosilicateReflector glassyesfront glass34.0 mmworking distance

    Lamp designE22 ellipticContour

    < 85.0

    F2

    34.0

    70

    Top

    65

    A

    A

    A = reference edgeDimensions in mm

    View from Rear

    Glass air guidesnot to scale

    30

  • P-VIP Replacement Lamps,Subject to alteration Page: 30

    DO DIS

    Lamp P-VIP 150/1.0 P21.5a

    Category FP Reflector P21.5 parabolic Arc gap 1.0 mm Power range 150 W Ignition 5 kV Light output typ.a 5,300 lm @ 150 W Average Life timeb 1,500 h @ 150 W Environmental Complies RoHS

    a) observed in 900 mm distance through 95 mm apertureb) when operated on OSRAM lamp driver PT VIP 150AC/380 O1

  • P-VIP Replacement Lamps,Subject to alteration Page: 31

    DO DIS

    Lamp P-VIP 150/1.0 P21.5a

    dimensions in mm

    07:30 oclocklocation contact 2a

    a) viewed from front

    04:30 oclocklocation contact 1a4 x, on all four sidesair inletscrystallizedReflector glassyesfront glassinfiniteworking distance

    Lamp designP21.5 parabolicContour

    < 73.056.0

    52.0 front view

    top

  • P-VIP Replacement Lamps,Subject to alteration Page: 32

    DO DIS

    Lamp P-VIP 100-120/1.3 E23ha

    Category MD TV Reflector E23 elliptic Arc gap 1.3 mm Power range 100 120 W Ignition 15 18 kV Light output typ.a 5,200 lm @ 120 W Average Life timeb > 6,000 h @ 120 W Environmental Complies RoHS

    a) observed in working distance through 6 mm apertureb) when operated on OSRAM lamp driver PT VIP 2AC/380 O1

  • P-VIP Replacement Lamps,Subject to alteration Page: 33

    DO DIS

    Lamp P-VIP 100-120/1.3 E23ha

    dimensions in mm

    03:00 oclocklocation contact 2a

    a) viewed from front

    central at baselocation contact 1ano, lamp closedair inletsborosilicateReflector glassyesfront glass52.0 mmworking distance

    Lamp designE23 ellipticContour

    < 88.0

    front view

    95.0 F2

    52.0

    top

  • P-VIP Replacement Lamps,Subject to alteration Page: 34

    DO DIS

    Lamp P-VIP 100-120/1.0 P22ha

    Category MD TV Reflector P22 parabolic Arc gap 1.0 mm Power range 100 120 W Ignition 15 18 kV Light output typ.a 3,800 lm @ 120 W Average Life timeb > 6,000 h @ 120 W Environmental Complies RoHS

    a) observed in 2400 mm distance through 160 mm apertureb) when operated on OSRAM lamp driver PT VIP 2AC/380 O1

  • P-VIP Replacement Lamps,Subject to alteration Page: 35

    DO DIS

    Lamp P-VIP 100-120/1.0 P22ha

    dimensions in mm

    04:30 oclocklocation contact 2a

    a) viewed from front

    central at baselocation contact 1ano, lamp closedair inletsborosilicateReflector glassyesfront glassinfiniteworking distance

    Lamp designP22 parabolicContour

    < 82.070.0

    65.0 front view

    top

  • P-VIP Replacement Lamps,Subject to alteration Page: 36

    DO DIS

    Lamp P-VIP 120-132/1.0 P22ha

    Category MD TV Reflector P22 parabolic Arc gap 1.0 mm Power range 120 132 W Ignition 15 18 kV Light output typ.a 4,500 lm @ 132 W Average Life timeb > 6,000 h @ 132 W Environmental Complies RoHS

    a) observed in 2400 mm distance through 160 mm apertureb) when operated on OSRAM lamp driver PT VIP O1 RP 132

  • P-VIP Replacement Lamps,Subject to alteration Page: 37

    DO DIS

    Lamp P-VIP 120-132/1.0 P22ha

    dimensions in mm

    04:30 oclocklocation contact 2a

    a) viewed from front

    central at baselocation contact 1a1 x TOP, 1 x BOTTOMair inletsborosilicateReflector glassyesfront glassinfiniteworking distance

    Lamp designP22 parabolicContour

    < 82.070.0

    65.0 front view

    top

  • P-VIP Replacement Lamps,Subject to alteration Page: 38

    DO DIS

    Lamp VIP R 120/P12a

    Category FP Reflector E18 elliptic Arc gap 1.0 mm Rated power 120 132 W Ignition 5 kV Light output typ.a 4,900 lm @ 132 W Average Life timeb > 3,000 h @ 132 W Environmental Complies RoHS

    a) observed in working distance through 5.0 x 3.8 mm2 rectangular apertureb) when operated on OSRAM lamp driver PT VIP 120AC/100-240 Q1

  • P-VIP Replacement Lamps,Subject to alteration Page: 39

    DO DIS

    Lamp VIP R 120/P12a

    dimensions in mm

    01:30 oclocklocation contact 2a

    a) viewed from front

    10:30 oclocklocation contact 1a

    burner extends overreflector rim

    air inletsborosilicateReflector glassnofront glass26.6 mmworking distance

    Lamp designE18 ellipticContour

    < 45.0

    F2

    26.6

    < 3.5

    48.0

    43.7

    front view

    top

  • P-VIP Replacement Lamps,Subject to alteration Page: 40

    DO DIS

    Lamp VIP R 120/P16a

    Category FP Reflector P16 elliptic Arc gap 1.0 mm Rated power 120 W Ignition 20 kV Light output typ.a 4,400 lm @ 120 W Average Life timeb >1,500 h @ 120 W Environmental Complies RoHS

    a) observed in working distance through 5.0 x 3.8 mm2 rectangular apertureb) when operated on OSRAM lamp driver PT VIP 120AC/100-240 H

  • P-VIP Replacement Lamps,Subject to alteration Page: 41

    DO DIS

    Lamp VIP R 120/P16a

    dimensions in mm

    SMK 101CCT-92-01 maleHV plug

    70/100 mm leads with plugattached to lamp

    HV contacting1 x left, 1 x rightair inletsborosilicateReflector glassfront cap incl. front glassfront glass26.0 mmworking distance

    Lamp designP16 ellipticContour

    < 70.0

    F2

    26.0

    front view

    top

    47.8

    49.7

  • P-VIP Replacement Lamps,Subject to alteration Page: 42

    DO DIS

    Lamp VIP R 150/P16a

    Category FP Reflector P16 elliptic Arc gap 1.3 mm Rated power 150 W Ignition 20 kV Light output typ.a 5,200 lm @ 150 W Aaverage Life timeb >3,000 h @ 150 W Environmental Complies RoHS

    a) observed in working distance through 5.0 x 3.8 mm2 rectangular apertureb) when operated on OSRAM lamp driver PT VIP 150AC/100-240 H2

  • P-VIP Replacement Lamps,Subject to alteration Page: 43

    DO DIS

    Lamp VIP R 150/P16a

    dimensions in mm

    SMK 101CCT-92-01 maleHV plug

    70/100 mm leads with plugattached to lamp

    HV contacting1 x left, 1 x rightair inletsborosillicateReflector glassfront cap incl. front glassfront glass26.0 mmworking distance

    Lamp designP16 ellipticContour

    < 70.0

    F2

    26.0

    front view

    top

    47.8

    49.7

  • P-VIP Replacement Lamps,Subject to alteration Page: 44

    DO DIS

    Lamp P-VIP 150/1.3 E21.5a

    Category FP Reflector E21.5 elliptic Arc gap 1.3 mm Rated power 150 W Ignition 16 kV Light output typ.a 5,500 lm @ 150 W Average Life timeb > 2,500 h @ 150 W Environmental Complies RoHS

    a) observed in working distance through 5.0 x 3.8 mm2 rectangular apertureb) when operated on OSRAM lamp driver PT VIP 150AC/100-240 H1

  • P-VIP Replacement Lamps,Subject to alteration Page: 45

    DO DIS

    Lamp P-VIP 150/1.3 E21.5a

    dimensions in mm

    01:30 oclocklocation contact 2a

    a) viewed from front

    central at baselocation contact 1aslot on left sideair inletsaborosilicateReflector glassyesfront glass17.3 mmworking distance

    Lamp designE21.5 ellipticContour

    < 76.5

    F2

    17.356.0

    52.0 front view

    top

  • P-VIP Replacement Lamps,Subject to alteration Page: 46

    DO DIS

    Lamp VIP R 150/P22a

    Category FP Reflector P22 parabolic Arc gap 1.3 mm Power range 150 W Ignition 16 kV Light output typ.a 3800 lm @ 150 W Average Life timeb 1000 h @ 150 W Environmental Complies RoHS

    a) observed in 900 mm distance through 95 mm apertureb) when operated on OSRAM lamp driver PT VIP 150AC/100-240 H1

  • P-VIP Replacement Lamps,Subject to alteration Page: 47

    DO DIS

    Lamp VIP R 150/P22a

    dimensions in mm

    4:30 oclocklocation contact 2a

    a) viewed from front

    central at baselocation contact 1ano, lamp closedair inletsborosilicateReflector glassyesfront glassinfiniteworking distance

    Lamp designP22 parabolicContour

    < 82.070.0

    65.0 front view

    top

  • P-VIP Replacement Lamps,Subject to alteration Page: 48

    DO DIS

    Lamp P-VIP 180/1.0 E20a

    Category FP Reflector E20 elliptic Arc gap 1.0 mm Rated power 180 W; Dimm: 156 W Ignition 5 kV Light output typ.a 6,800 lm @ 180 W Average Life timeb >3,000 h @ 180 W Environmental Complies RoHS

    a) observed in working distance through 5.0 x 3.8 mm2 rectangular apertureb) when operated on OSRAM lamp driver PT VIP 180AC/100-240 H1

  • P-VIP Replacement Lamps,Subject to alteration Page: 49

    DO DIS

    Lamp P-VIP 180/1.0 E20a

    dimensions in mm

    SMK 101CCT-92-01 maleHV plug

    100/100 mm leads withplug attached to lamp

    HV contacting1 x left, 1 x rightair inletsborosilicateReflector glassfront cap incl. front glassfront glass26.0working distance

    Lamp designE20 ellipticContour

    < 70.0

    F2

    26.0

    front view

    top

    47.8

    49.7

  • P-VIP Replacement Lamps,Subject to alteration Page: 50

    DO DIS

    Lamp P-VIP 200/1.0 P21.5a

    Category FP Reflector P21.5 parabolic Arc gap 1.0 mm Power range 200 W, Dimm: 160W Ignition 5 kV Light output typ.a 8,000 lm @ 200 W Average Life timeb 1,500 h @ 200 W Environmental Complies RoHS

    a) observed in 900 mm distance through 95 mm apertureb) when operated on OSRAM lamp driver PT VIP 3AC/380 O3

  • P-VIP Replacement Lamps,Subject to alteration Page: 51

    DO DIS

    Lamp P-VIP 200/1.0 P21.5a

    dimensions in mm

    07:30 oclocklocation contact 2a

    a) viewed from front

    04:30 oclocklocation contact 1a4 x, on all four sidesair inletscrystallizedReflector glassyesfront glassinfiniteworking distance

    Lamp designP21.5 parabolicContour

    < 73.056.0

    52.0 front view

    top

  • P-VIP Replacement Lamps,Subject to alteration Page: 52

    DO DIS

    Lamp P-VIP 200/1.0 E19a

    Category FP Reflector E19 elliptic Arc gap 1.0 mm Power range 200 W Ignition 2.5 5 kV Light output typ.a 8,200 lm @ 200 W Average Life timeb 2,500 h @ 200 W Environmental Complies RoHS

    a) observed in working distance through 5.0 x 3.8 mm2 rectangular apertureb) when operated on OSRAM lamp driver PT VIP O3 MID 200

  • P-VIP Replacement Lamps,Subject to alteration Page: 53

    DO DIS

    Lamp P-VIP 200/1.0 E19a

    dimensions in mm

    01:30 oclocklocation contact 2a

    a) viewed from front

    10:30 oclocklocation contact 1a

    burner extends overreflector rim

    air inletscrystallizedReflector glassnofront glass37.7 mmworking distance

    Lamp designE19 ellipticContour

    < 42.546.0

    46.0 F2

    37.7

    < 13.5

    rear view

    top

  • P-VIP Replacement Lamps,Subject to alteration Page: 54

    DO DIS

    P-VIP and VIP after sales lampsGeneral description New after sales lamps Existing after sales lamps Instruction for use

    P-VIP Replacement Lamps Agenda

  • P-VIP Replacement Lamps,Subject to alteration Page: 55

    DO DIS

    P-VIP Instruction for Use

    For lamp replacement switch off power, disconnect mains supply, disconnect power cord,

    allow lamp to reach room temperature.

    This P-VIP lampoperates at high pressure and at high temperature and may

    unexpectedly shatter.generates ultraviolet radiation which may cause skin and

    eye irritation with prolonged exposure.must be operated only in suitably designed, enclosed fixtures which

    prevent direct observation of the arc and will prevent lamp fragments from exiting, in the unlikely event of a lamp rupture.

  • P-VIP Replacement Lamps,Subject to alteration Page: 56

    DO DIS

    P-VIP Instruction for Use

    Do not touch the lamp with bare hands.If necessary, lamp can be cleaned with lint free towel

    before operation.Protect lamp environment against high ignition pulses

    Front projection max. 8 kV and rear projection max. 23 kVAvoid direct contact of objects to reflector cover glass.This lamp must not be operated with a broken, cracked

    or loose reflector or cover glass.Fast on-off-cycles will reduce lamp life ( 10 min on/off)Operate lamp only in accordance with UL 1950 regulations.Avoid back-reflection of light into burner.

  • P-VIP Replacement Lamps,Subject to alteration Page: 57

    DO DIS

    P-VIP Instruction for Use

    DisposalFor disposal of spent lamps, always consult federal, state, local and

    provincial hazardous waste disposal rules and regulations to ensure proper disposal.

    CautionThis lamp emits ultra violet (UV) radiation and operates at high pressure.

    This lamp may only be used in enclosed fixtures that comply with UL1572. Due to the high luminous efficacy, the UV radiation which the lamp emits and the high pressure within the lamp, P-VIP lamps may only be operated within enclosed, purpose-built housings.