optional mit microwave motion sensor - ledlum · led tri-proof light led tri-proof light 1 2 3...
TRANSCRIPT
LEDLUM LTX TRI-PROOF
5.8GHz566
Tri-Proof LTX Serie
Microwave Motion SensorOptional mit
E.COM GmbH
Direkt Montage Schwenkbare Montage
Seilabhänger Montage
D
Copyright C 2016 Spring
TF E.Com GmbH
Temperature Characteristics T-ambient 25 C
Temperature
Operating -20~+40℃Storage -40~+85℃
Electrical CharacteristicsInput Voltage: US AC100~277V 50/60Hz
EU AC200~240V 50/60Hz
PF≥0.93 THD<20%≥0.90
O
Before installing the lighting fixtures, please read this instruction manual carefully.
The lighting fixtures should be installed, connected and tested by a certified installer based on the local regulations.
Lamps should always be installed or replaced with care.
Please check the local voltage in accordance with the product requirements before using the product.
Relamping only can be done when the power is off and the lamp is completely cooled down.
When a lamp is to be cleaned, make the power off and let it cool down completely.Clean the fixture with a soft cloth and a standard PH neutral detergent. Stainless steel finishing should be maintained regularly.
Misuse of, or changes to the fixture shall nullify the guarantee.
Don’t cover the fixtures with flammable materials.
Exclusively replaced by the manufacturer or his service agent or the similar qualified person in order to avoid a hazard.
/01
Matters needing attention
1 Type Linear
2 Length code
3 Power code
4 Version
PS:
WW(3000K) NW(4000K) DW(5000K) CW(6500K)CCTRange:
Product Number Explanation
ledlum LTX1560/1R
www.ledlum.com
LEDLUM LTX Tri-Proof
TF E.Com GmbH
/02Copyright C 2016 Spring
With sufficient ambient light,the sensor does not switch on the lamp.
With insufficient ambient light,the sensor switches on thelamp when motion is detected.
After hold time , the sensordims the lamp at a low lightlevel if no new motion trigger.
After stand-by period , the sensor switches off the lamp is no motionis detecred in its detection zone.
Steps dimming control demonstration
www.ledlum.com
LEDLUM LTX Tri-Proof
Optional mit LTX Microwaver Sensor Technical Data
TF E.Com GmbH
/03Copyright C 2016 Spring
Special application for underground parking
Widely used
Parking lot
Offices
Factories
Passageway
subway station
Warehouse
Stadium
Detection radius up to 10m ,diameter up to 20m
For general parking,when the car close to the lamp will light up, such easy to cause the driver could not be instantly adapt to light shifting sharply and discomfort,however,LEDLUM provide aperfect solution for such a defect,it can make the driver the car at a distance of 10 meters off the lamps then light up automatically.
2.5m3m
4m
10m
10m
5m 6m8m
10m
www.ledlum.com
LEDLUM LTX Tri-Proof
TF E.Com GmbH
SupermarketExhibition hallParking placeEtc
COMMERCIAL LIGHTING PUBLIC LIGHTING INDUSTRIAL LIGHTING
TunnelMTR stationTrain stationBus stationAirportEtc
Factory/WarehouseEtc
/04
Patent and functional design with imaginative appearance
High stability isolated driver
Excellent heat dissipation depending on whole aluminum housing
Maximum efficacy and minimum glare
High-tech optical design
No UV ,No lead, No mercury
LEDLUM LTX Tri-proof led fixture for IP66 water-proof,dustproof and corrosion-proof
Model NO.
ledlum LTX0620
Size C(mm)
84
84
84
84
84
Size A(mm)
600
900
1200
1500
1500
Size B(mm)
71
71
71
71
71
Size D(mm)
800
800
800
800
800
1. Features
2.Application
3.Product Dimension
With lux sensorOptional als LTX Emergency Tri-Proof
Sensor hidden in the lamp
Copyright C 2016 Spring
Drive with over current ,over voltage and over temperature protection
R
ledlum LTX0930R
ledlum LTX1240R
ledlum LTX1550R
ledlum LTX1560/1R
www.ledlum.com
LEDLUM LTX Tri-Proof
TF E.Com GmbH
A : Make a right position and screw hole B : Screw the steel cable onto the ceiling
A.Suspending
Ceiling
Open hole
Electric drill Steel cable
Power ONPower OFF
Power OFF
PLS note : PLS put the terminal of
power cable into water proof box
and use a listed water proof bushing
when you link the power
C : Hung the fixture under the steel cable and secure the fixture by steel cable
D: Adjust the position of the fixture and clean it..
Model NO.
2835
2835
2835
2835
2835
Light Source
108
156
216
264
324
LED QTY (pcs)
20
30
40
50
65
Power (W)
6000K
6000K
6000K
6000K
6000K
CCT (K)
CRI
>80
>80
>80
>80
>80
Cover Lm/W
150
150
150
150
150
ClearLumens
3000
4500
6000
7500
9750
Cover Lm/W
140
140
140
140
140
Frosted Lumers
2800
4200
5600
7000
9100
BeamAngle
120o
120o
120o
120o
120o
/05
4. Parameter
5.Installation
WW(3000K) NW(4000K) DW(5000K) CW(6500K)CCTRange:
Copyright C 2016 Spring
ledlum LTX0620R
ledlum LTX0930R
ledlum LTX1240R
ledlum LTX1550R
ledlum LTX1560/1R
www.ledlum.com
LEDLUM LTX Tri-Proof
TF E.Com GmbH
A: Make a right position and screw hole
C: Install the lamp into the clips. D: Adjust the position of the fixture and clean it..
B: Screw the clip on the ceiling tightly
Open hole
Electric drill
LED Tri-proof light
Metal clip
Screw driver
Open hole
Screw
Metal clip
B.Ceiling Mounted
Power OFF
Note : pls put the terminal of power cable into water proof box and use a listed water proof bushing when you link the power
Copyright C 2016 Spring
Power ON
Power OFF
/06
Pls note :
Metal Card
One package two pcs
Standard accessories Optional accessories
Above installation“ B” belongs to our standard installation, if you want to choose our way of “A” installation then you need to select our optional accessories and pay.
steel cable
One package two pcs
6.Wiring diagram
LED lampL
L
NPE
PE
NAC 100-277V/200-240V
www.ledlum.com
LEDLUM LTX Tri-Proof
TF E.Com GmbH
7.Packaging
LED Tri-proof light
LED Tri-proof light
1
2
3
Metal card buckle
Metal card buckle
Manual
1pc
2pcs
Model NO.
2pcs
4 Steel cable 2pcs5
Adjustable buckle
1pcs
A.Pack listQuantitySequence
Number
1 6 685x307x223
985x307x2231
Model No
6
B.Packing Data
6pcs/cart on
1.877 12.362
17.0742.579
1 6 1285x307x223
1585x307x2231
1
6
3.342 22.152
27.0864.096
1585x307x2236 27.0864.096
N .W. / pcs(kg)
SingleBox Pcs/CTN G .W. /CTN
(kg)Meas(mm)
9.AttentionThis specification is for reference only,we reserve the right to change without notice.If you need the updated info,please contact local distributors or visit our website at http://www.ledlum.com.
/07Copyright C 2016 Spring
Safety standards UL 8750; UL 1598; EN 60598-1: 2015; EN 60598-2-2: 2012;EN 62031: 2008+A1: 2013+A2: 2015; EN 62493: 2015; EN 62471: 2008;EMC emission Compliance to EN55015: 2013,EN61000-3-2: 2014; EN61000-3-3: 2013;EMC immunity Compliance to EN61547: 2009; Certification D EN 60598-2-24;
8.Safety & EMC
ledlum LTX0620R
ledlum LTX0930R
ledlum LTX1240R
ledlum LTX1550R
ledlum LTX1560/1R
www.ledlum.com
LEDLUM LTX Tri-Proof