Optical Systems
Brand-Rex is committed to a future in optical cabling
and truly believes in the benefits of optical cables for the
future requirement of both LAN and WAN networks, why?
Here are some of the benefits of Optical Systems.
• Transmission Security – As fibre emits no
electromagnetic energy there is no opportunity to
intercept transmissions.
• Bandwidth – Optical Fibre has a much
greater data capacity than copper, carrying more
data further.
• Transmission Distance – Optical systems
have much lower attenuation than copper systems
meaning that signals can be transmitted further.
• No Risk of EMI or RFI – Fibre optic
systems being primarily glass have
no risk of electromagnetic or radio
frequency interference.
• Non-conductive – Optical Cables provide total electrical
isolation with no need to ground loops at
equipment terminations.
Optical Systems Contents
3.1
Distribution Cables CType Page 3.7
Breakout Cables TType Page 3.9
Loose Tube Cables Unitube Page 3.14
MultiLooseTube Page 3.18
Optical Components Pig/Patch Page 3.34
Panels Page 3.39
ConnectorsandAdaptors Page 3.41
Tools Page 3.45
Blolite Page 4.1
3.2
Cabled Optical Fibre Specifications
CABLE SELECTION:
When selecting the correct cable for any
installation the first question will be of
fibre type. This will be dependent upon
the transmission distance and the protocol
being adopted. Further on in this section
is a key to transmission distances on the
main fibre types for 1Gb and 10 Gb Ethernet
applications. This key is repeated on each
page as a reference.
With the choice of fibre type complete,
the selection of cable construction must be
made. There are several key questions that
must be answered in determining
cable selection.
Fibre Count -
How many fibres are required?
This should take into account future demand
and allow an element of redundancy. The
cost of installation and associated down
time will generally outweigh the cost of
additional fibre on day one.
Additionally, good practice should be taken
into consideration. A large high fibre count
cable carrying the majority of a company's
data generates a larger risk than several
lower fibre count cables should any cable
damage occur. Diversity in routing should
also be considered in answering
this question.
Cable Properties –
What type of cable is required?
The prime function of the cable is to provide
a safe path for the fibre during and post
installation. There are a wide variety of cable
types to choose from depending on how
and where the cable is to be installed.
A summary of the main construction variants
and their intended usage is given below.
Sheath Options: Universal Cables
These cables are designed for use both
internally and externally. They have a Low
Smoke Zero Halogen compound sheath that
reduces the emission of toxic fumes and
stops the spread of fire.
Outdoor Cables
These cables are designed only for external
use. They have a Low Density Polyethylene
sheath that makes the cable lighter than the
LSZH version. The Polyethylene sheath also
has a much smoother finish. This combined
with reduced weight makes Outdoor Cables
more suited to the longer pulled runs into
which they are generally installed. Outdoor
Cables may enter buildings, however they
must not pass more than 3m into the
building under current regulations.
Cable Options:Premise Distribution System (PDS) Cables
Page 3.7 to 3.8
These cables are based on a 900 µm tight
buffered element and are generally installed
in the backbone of a building network and
direct terminated at a consolidation point.
Brand-Rex PDS cables manufactured in
our state of the art UK based factory and
consist of up to 24 individual tight buffered
elements and distributed strength members.
The product is then sheathed with a LSZH
compound making it suitable for internal
and external applications.
Breakout and Patch Cables
Page 3.9 to 3.12
To produce the building block for breakout
cables, a 900 µm tight buffered element is
sheathed with an additional layer of LSZH
compound over a layer of aramid yarns.
This forms a simplex sub unit that can be
used in the production of optical patch
cords or used for fibre to the desk (FTTD)
applications; additionally it forms the base
unit for the breakout cables.
Brand-Rex breakout cables are generally
installed within equipment rooms as rack to
rack links and are manufactured in our state
of the art UK based factory. They consist of
up to 24 simplex sub units with additional
strength members and an outer LSZH
universal sheath.
Loose Tube Cables
Page 3.13 to 3.32
Loose tube cables provide for higher fibre
counts than are commonly available in tight
buffer element based products such as PDS
and breakout cables. They can generally be
installed as building or campus links and
are available in a variety of constructions
offering different mechanical performance.
The building block of a loose tube cable is a
PBT tube that contains up to 24 individually
inked optical fibres suspended in a gel
material to provide protection and prevent
water ingress. These gel filled loose tubes
are used to produce either Unitube or Multi
Loose Tube cables.
Brand-Rex loose tube cables are
manufactured in our UK based optical facility
and are available in 4 standard variants;
1. Duct Grade
2. Rodent Resistant Glass Armoured
3. Direct Burial Grade – Single Sheath
4. Direct Burial Grade – Twin Sheath
All 4 variants are available as either Unitube
or Multi Loose tube cable. Unitube products
are available with up to 24 fibres and Multi
Loose Tube products are available with up to
144 fibres as standard, although higher fibre
counts are available on request.
The Unitube products take a single gel filled
loose tube and apply the relevant armouring
and then either a Universal LSZH sheath or
a Polyethylene outdoor sheath. The Multi
Loose Tube products take up to 12 gel filled
loose tubes and strand them around a glass
central strength member before adding the
relevant armouring and either a Universal
LSZH sheath or a Polyethylene
outdoor sheath.
3.3
Cabled Optical Fibre Specifications
The tables below describe the standard fibres supplied by Brand-Rex that comply with or exceed ISO11801 and EN50173-1 : 2002 requirements, for use in high speed LAN, MAN, WAN data and telecom networks. Specific Fibre Types to customer specification are available on request.
Part Number IdentifierIEC 60793-2-10 CategoryITU-T RecommendationISO 11801 Class Cabled Optical Performance of FibreAttenuation @ 850 / 1300nm (dB.km)Bandwidth @ 850 / 1300nm (MHz.km)Attenuation @ 1310 / 1550nm (dB/km)Dispersion @ 1310 / 1550nm (ps/nm.km)Numerical ApertureRefractive Index @ 850nmRefractive Index @ 1300nmRefractive Index @ 1310 / 1550nmGeometrical DataCore Diameter (µm)Core / Cladding Concentricity Error (µm)Overall Coating Diameter (µm)Coating Concentricity Error (µm)Mechanical DataProof Test Level
L62A1b
≤ 3.2 / ≤ 0.8≥ 160 / ≥ 300
n/an/a
0.275 +/- 0.0151.4951.49n/a
62.5 +/-2.5≤ 3
245 +/-10≤ 12.5
≥ 1%≥ 100kpsi
L50A1a
G.651
≤ 2.8 / ≤ 0.8≥ 300 / ≥ 400
n/an/a
0.200 +/- 0.021.4811.476
n/a
50 +/-2.5≤ 3
245 +/-10≤ 12.5
≥ 1%≥ 100kpsi
Part Number IdentifierIEC 60793-2-10 CategoryITU-T RecommendationISO 11801 Class Cabled Optical Performance of FibreAttenuation @ 850 / 1300nm (dB.km)LED Launch Bandwidth @ 850 / 1300nm (MHz.km)
Laser Launch Bandwidth @ 850nm (MHz.km)Attenuation @ 1310 / 1550nm (dB/km)Dispersion @ 1310 / 1550nm (ps/nm.km)Numerical ApertureRefractive Index @ 850nmRefractive Index @ 1300nmRefractive Index @ 1310 / 1550nmGeometrical DataCore Diameter (µm)Mode Field Diametre (µm)Core / Cladding Concentricity Error (µm)Overall Coating Diameter (µm)Coating Concentricity Error (µm)Mechanical DataProof Test Level
062A1b
OM1
≤ 3.2 / ≤ 0.8≥ 200 / ≥ 500
n/an/a
0.275 +/- 0.0151.4951.49n/a
62.5 +/-2.5≤ 3
245 +/-10≤ 12.5
≥ 1%≥ 100kpsi
H62A1b
OM1
≤ 3.2 / ≤ 0.8≥ 250 / ≥ 800
n/an/a
0.275 +/- 0.0151.4951.49n/a
62.5 +/-2.5≤ 3
245 +/-10≤ 12.5
≥ 1%≥ 100kpsi
050A1a
G.651OM1 & OM2
≤ 2.8 / ≤ 0.8≥ 500 / ≥ 500
n/an/a
0.200 +/- 0.021.4811.476
n/a
50 +/-2.5≤ 3
245 +/-10≤ 12.5
≥ 1%≥ 100kpsi
H50A1a
G.651OM1 & OM2
≤ 2.8 / ≤ 0.8≥ 600 / ≥ 1200
n/an/a
0.200 +/- 0.021.4811.476
n/a
50 +/-2.5≤ 3
245 +/-10≤ 12.5
≥ 1%≥ 100kpsi
D08B1.3
G.652.c / G.652.dOS1 and OS2
n/a n/a
≤ 0.38 / ≤ 0.25≤ 3.5 / ≤ 18
n/an/an/a
1.470
9.3
≤ 0.8245 +/-10≤ 12.5
≥ 1%≥ 100kpsi
008B1.1
G.652.a / G.652.bOS1
n/an/a
≤ 0.38 / ≤ 0.25≤ 3.5 / ≤ 18
n/an/an/a
1.470
9.3
≤ 0.8245 +/-10≤ 12.5
≥ 1%≥ 100kpsi
OM3A1a.2G.651OM3
≤ 2.8 / ≤ 0.8≥ 2000 / ≥ 500
≥ 1500n/an/a
0.200 +/- 0.0151.4821.477
n/a
50 +/-2.5
≤ 1.5245 +/-10≤ 12.5
≥ 1%≥ 100kpsi
Z50A1a.2G.651OM3
≤ 2.8 / ≤ 0.8≥ 3500 / ≥ 500
≥ 1500n/an/a
0.200 +/- 0.0151.4821.477
n/a
50 +/-2.5
≤ 1.5245 +/-10≤ 12.5
≥ 1%≥ 100kpsi
To serve the requirements of optical systems
customers, Brand-Rex has created a standard
range of Tight Buffered and Loose Tube
cables that will meet most requirements.
The standard specification of these cables is
described in the detail on this page.
As a company that is driven by our
customers needs, Brand-Rex will always be
happy to offer non-standard products to
order based on your own specification.
This includes complex requirements ranging
from fire survival constructions to simple
requirements such as composite cables,
custom sheath colours or printing. Please
enquire about our customer cable service.
STANDARD SHEATH MARKINGS OPTICAL CABLES:
KEY: Sequential length marking
Fibre Type
Cable Type
Fibre Count
Construction
Week of Manufacture
Year of Manufacture
STANDARD SHEATH COLOUR - LOOSE TUBE AND DISTRIBUTION CABLE:
LSZH Black
Polyethylene Black
Other colours available on request subject
to minimum order quantity.
STANDARD SHEATH COLOUR - BREAKOUT and PATCH CABLE:
Multi Mode: Orange
Single Mode Yellow
Note: • For T2 and above, both sub unit sheath
and outer sheath follow this format.• Numeric Identification is provided
on sub units on T2 and greater.
STANDARD BUFFER COLOUR - BREAKOUT and PATCH CABLE:
62.5/125: Blue
50/125 Green
OM3 Grey
8/125: Yellow
Optical Cable Manufacturing Standards
MFOS Standard Cable Range
STANDARD TIGHT BUFFERED FIBRE COLOURS:
1. Blue
2. Orange
3. Green
4. Brown
5. Grey
6. White
7. Red
8. Black
9. Yellow
10. Violet
11. Pink
12. Turquoise
13. Blue/Black
14. Orange/Black
15. Green/Black
16. Brown/Black
17. Grey/Black
18. White/Black
19. Red/Black
20. Natural/Black
21. Yellow/Black
22. Violet/Black
23. Pink/Black
24. Turquoise/Black
STANDARD INKED FIBRE COLOURS:
1. Blue
2. Orange
3. Green
4. Brown
5. Grey
6. White
7. Red
8. Black
9. Yellow
10. Violet
11. Pink
12. Turquoise
STANDARD MULTI LOOSE TUBE IDENTIFICATION:
1. Red
2. Green
3. Natural
4. Natural
5. Natural
6. Natural
7. Natural
8. Natural
9. Natural
10. Natural
11. Natural
12. Natural
Note: Where fillers are present in a loose
tube design, these will be used as
markers and coloured accordingly.
3 .4
3.5
MFOS Link and Channel Transmission Distances
The MFOS product range can be used for
conventional structured cabling systems
installations and for centralised optical fibre
installations. MFOS supports the 2000m
home run cabling schemes as described in
ISO 11801 : 2002 and the 300m cabling
described in TSB 72, Centralised Optical
Fibre Guidelines and TIA/EIA 568B.
Link transmission distances are either
attenuation limited or bandwidth limited.
In attenuation limited installations the
individual loss of each component is
summed for all the parts in the link and the
sum must fall within the loss limit for the
fibre type.
Below is a summary of the drive distances
possible on optical fibre links based on
specific protocols. Assuming that the link
falls within the attenuation budget of the
technology, the distances are recommended
based on a typical link comprising 2 splices
and 2 connectors.
CentralComputerRoom
Optical Patch Panel
Building Riser
Wall/Floor Outlet
Terminal
Fibre Type
L62 - 62.5/125160/300 Mhz.km062 - 62.5/125 200/500 Mhz.kmH62 - 62.5/125 250/800 Mhz.kmL50 - 50/125300/400 Mhz.km050 - 50/125 500/500 Mhz.kmH50 - 50/125 600/1200 Mhz.kmOM3 - 50/1252000/500 Mhz.kmZ50 - 50/125 3500/500 Mhz.km008 - 8/125 G652a/b D08 - 8/125 G652c/d
850nm
1300nm
850nm
1300nm
850nm
1300nm
850nm
1300nm
850nm
1300nm
850nm
1300nm
850nm
1300nm
850nm
1300nm
1310nm
1550nm
1310nm
1550nm
2 Splice - 2 Connector Link Distances in metres
10 Gigabit Ethernet
0
0
25
300
65
450
0
0
83
300
110
900
300
300
550
300
10000
40000
10000
40000
1 Gigabit Ethernet
0
0
300
600
500
1000
0
0
600
600
750
2000
900
550
1100
550
10000
40000
10000
40000
100Mb Ethernet
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
10000
10000
10000
10000
Identifier
L62
062
H62
L50
050
H50
OM3
Z50
008
D08
Tight Buffered Cables
Distribution Cables - PDS
Single Fibre Cable
Zip Cord
Breakout Cables
Unitube Cables
Universal Duct Grade - UDU
Universal Glass Yarn Armoured - URU
Universal Steel Tape Armoured - USU
Universal Steel Tape Armoured Twin - USU2
External Duct Grade - UDE
External Glass Yarn Armoured - URE
External Steel Tape Armoured - USE
External Steel Tape Armoured Twin - USE2
Multi Loose Tube Cables
Universal Duct Grade - MDU dd
Universal Glass Yarn Armoured - MRU dd
Universal Steel Tape Armoured - MSU dd
Universal Steel Tape Armoured Twin - MSU2 dd
External Duct Grade - MDE dd
External Glass Yarn Armoured - MRE dd
External Steel Tape Armoured - MSE dd
External Steel Tape Armoured Twin - MSE2 dd
Value Construction
VFfffCxxLU
-
-
-
VFfffUNIxxLU
-
-
-
-
-
-
-
6 x 4 Fibres Per Tube
HFfffSxxWLU
HFfffSxxW(E)LU
HFfffSxxWSTALU
HFfffSxxWLSTALU
HFfffSxxWNM
HFfffSxxW(E)NM
HFfffSxxWSTANM
HFfffSxxWNMSTANM
Standard Construction
HFfffCxxLU
HFfffT1L
HFfffT2ZL
HFfffTxxLU
HFfffUNIxxLU
HFfffUNIxx(E)LU
HFfffUNIxxSTALU
HFfffUNIxxLSTALU
HFfffUNIxxNM
HFfffUNIxx(E)NM
HFfffUNIxxSTANM
HFfffUNIxxNMSTANM
6 x 12 Fibres Per Tube
HFfffSxxWLU
HFfffSxxW(E)LU
HFfffSxxWSTALU
HFfffSxxWLSTALU
HFfffSxxWNM
HFfffSxxW(E)NM
HFfffSxxWSTANM
HFfffSxxWNMSTANM
12 x 12 Fibres Per Tube
HFfffSxxWLU
HFfffSxxW(E)LU
HFfffSxxWSTALU
HFfffSxxWLSTALU
HFfffSxxWNM
HFfffSxxW(E)NM
HFfffSxxWSTANM
HFfffSxxWNMSTANM
3.6
Cable Properties and Installation
Type of Cable
Cable Range
CableProperties
Water BlockedThe cable has been tested for water penetration in accordance with IEC 60794-1-F5 and has less than 3m penetration in a 24hr period under a 1m head of water.
Fire RetardantThe cable is sheathed in a Low Smoke Zero Halogen material and offers IEC 60332-1 performance.
Rodent ResistantThe cable has armouring which offers a degree of resistance to attack from rodents. • Level 1 minimum • Level 3 maximum
Non MetallicThe cable is free from metallic elements.
Suitable Installation
Internal InstallationA cable designed for installation in trunking and floor / roof voids.
Duct BuriedDuct Grade Cable that can be installed into buried duct / sub duct by pulling, winching or blowing.
Direct Buried A direct burial grade of cable, which has excellent crush resistance and is designed for direct burial installation.
ExternalInternalUniversalSuitable for internal and external use.
Suitable for internal use. Suitable for external use.
DISTRIBUTION CABLES
MFOS distribution cables are based around
standard 900 µm tight buffered element
which offers excellent environmental
performance. The standard range of
distribution cables is available with up to 24
fibres and the cables are designed for use in
building backbone applications. Cable can
be installed in cable conduits by pulling or
alternatively can be laid in
roof / floor voids.
The MFOS distribution cable range has
a Low Smoke Zero Halogen sheath and
mechanical strength is derived from aramid
strength members surrounding the multiple
tight buffered cores.
3 .7
Optical Systems
MillenniuM Optical Cables - Universal PDSTight Buffered Premise Distribution Cables
Compact Design
Water Blocked Design
Low Smoke Halogen Free Sheath
PRODUCT DESCRIPTION:
For building backbone and horizontal
distribution applications, the PDS cable
range has been designed to be compact
and yet offer excellent tensile performance
making it suitable for a wide range of
applications. The universal construction
enables the cable to be used internally and
externally without the need for transition
cable joints.
All universal PDS cables are constructed
around the 900µm tight buffered elements
which are suitable for direct termination.
PRODUCT PERFORMANCE:
Crush (N):
2000
Impact (Nm):
15
Torsion (turns / m):
5
Fire:
IEC 60332-1
Temp - Operation:
-25°c to +70°c
Temp - Storage:
-40°c to +80°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
≤3m @ 24 hours
3.8
Premise Distribution Cables
4.60
5.30
5.60
6.10
23
29
33
40 920
730
640
460 45
55
65
60
70
80
95
6.70 45 1100 70 100
7.50 55 1430 75 113
8.50 65 1430 85 128
85
2 Fibre
4 Fibre
6 Fibre
8 Fibre
12 Fibre
16 Fibre
24 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
HF 062 C8 LU
HF 062 C6 LU
HF 062 C4 LU
HF 062 C2 LU
8 Fibre
12 Fibre
16 Fibre
24 Fibre
6 Fibre
4 Fibre
2 Fibre
62.5/125 50/125 OM3 8/125
HF 050 C8 LU
HF 050 C6 LU
HF 050 C4 LU
HF 050 C2 LU
HF OM3 C8 LU
HF OM3 C6 LU
HF OM3 C4 LU
HF OM3 C2 LU
HF 008 C8 LU
HF 062 C12 LU HF 050 C12 LU HF OM3 C12 LU HF 008 C12 LU
HF 062 C16 LU HF 050 C16 LU HF OM3 C16 LU HF 008 C16 LU
HF 062 C24 LU HF 050 C24 LU HF OM3 C24 LU HF 008 C24 LU
HF 008 C6 LU
HF 008 C4 LU
HF 008 C2 LU
Product Part Numbering
LSZH Sheath
Ripcords
Aramid Strength Members
900µm Tight Buffered Fibre
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
Fibre Selection
BREAKOUT AND PATCH CORD CABLES
MFOS breakout cables are based on
standard 2.80mm single fibre cable
sub units and are designed for use in
building backbone applications or for
cross connections in equipment rooms
with suitable terminations. The cables are
designed to be pulled into conduits or
alternatively can be placed in floor / roof
void cable trays.
The single fibre cable sub unit consists of
a 900 µm tight buffered fibre surrounded
with aramid yarns and a Low Smoke Zero
Halogen sheath.
The breakout cable takes these sub units,
and adds additional aramid strength
members plus an outer Low Smoke Zero
Halogen sheath to give a metal-free robust
and flexible breakout cable.
3 .9
Optical Systems
MillenniuM Optical Cables - SFC and ZIPRuggedised Fibre Patch Cable
Rugged Construction for Indoor,
Short Run Patching
Easily configured into patch cords
Colour coded for identification
PRODUCT DESCRIPTION:
Ruggedised tight buffered patching cable is
used in the manufacture of patch cords. The
robust construction is designed for short run
indoor patching or where frequent handling
is likely such as in equipment rooms, wiring
closets and at user outlets. The cable is
readily retained by industry standard
connectors and can easily be made into
a patch cord.
The single fibre cable is colour coded for
ease of identification during and
post installation.
PRODUCT PERFORMANCE:
Crush (N):
1500
Impact (Nm):
5
Torsion (turns / m):
5
Fire:
IEC 60332-1
Temp - Operation:
-10°c to +70°c
Temp - Storage:
-25°c to +80°c
Temp - Installation:
0°c to +70°c
62.5/125 50/125 OM3 8/125
HF 062 T1 L
HF 062 T2 ZL
1 Fibre
2 Fibre
HF 050 T1 L
HF 050 T2 ZL
HF OM3 T1 L
HF OM3 T2 ZL
HF 008 T1 L
HF 008 T2 ZL
Product Part Numbering
LSZH Sheath
Aramid Strength Members
900µm Tight Buffered Fibre
3 .10
Fibre Patch Cable
Colour Coding - Core
62.5/125 Blue
50/125 Green
OM3 Grey
008/125 Yellow
Colour Coding - Sheath
62.5/125 Orange
50/125 Orange
OM3 Orange
008/125 Yellow
Nonstandardcolouroptionsareavailableonrequest.
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
2.80
2.80 x 5.90
8
16
200
400
30
30 (minor axis)
45
45 (major axis)
1 Fibre
2 Fibre
MillenniuM Optical Cables - DUPRuggedised Duplex Breakout Cable
Rugged Construction for Indoor,
Short Run Patching
Easily configured into patch cords
Colour coded for identification
PRODUCT DESCRIPTION:
The duplex fibre cable is the building block
for ruggedised pigtail and patch cords.
The robust construction is designed for
short run indoor patching or where frequent
handling is likely such as in equipment
rooms, wiring closets and at user outlets.
PRODUCT PERFORMANCE:
Crush (N):
2000
Impact (Nm):
5
Torsion (turns / m):
5
Fire:
IEC 60332-1
Temp - Operation:
-10°c to +70°c
Temp - Storage:
-25°c to +80°c
Temp - Installation:
0°c to +70°c
HF 062 T2 L2 Fibre
62.5/125 50/125 OM3 8/125
HF 050 T2 L HF OM3 T2 L HF 008 T2 L
Product Part Numbering
3.80 x 6.60 29 400 40 (minor axis) 60 (minor axis)2 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
3.11
LSZH Outer Sheath
LSZH Unit Sheath
Aramid Strength Members
900µm Tight Buffered Fibre
Duplex Breakout Cable
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
Colour Coding - Core
62.5/125 Blue
50/125 Green
OM3 Grey
008/125 Yellow
Colour Coding - Ruggedised Unit
62.5/125 Orange
50/125 Orange
OM3 Orange
008/125 Yellow
MillenniuM Optical Cables - BKOBreakout Cables
Based on 2.80mm ruggedised sub units
Non metallic central strength member
Water blocked design
PRODUCT DESCRIPTION:
For use in building/campus backbone
applications or horizontal distribution, the
BKO product range is both lightweight and
compact yet offers good mechanical and
environmental performance.
The BKO product range consists of standard
2.80mm sub units around non metallic
central strength members. A layer of water
blocking tape is applied beneath the LSZH
outer sheath making the product suitable
for internal and external applications.
PRODUCT PERFORMANCE:
Crush (N):
2000
Impact (Nm):
30
Torsion (turns / m):
5
Fire:
IEC 60332-1
Temp - Operation:
-25°c to +70°c
Temp - Storage:
-40°c to +80°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24 hours
HF 062 T24 LU
HF 062 T16 LU
HF 062 T12 LU
HF 062 T8 LU
HF 062 T6 LU
HF 062 T4 LU
24 Fibre
16 Fibre
12 Fibre
8 Fibre
6 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 T24 LU
HF 050 T16 LU
HF 050 T12 LU
HF 050 T8 LU
HF 050 T6 LU
HF 050 T4 LU
HF 0M3 T24 LU
HF 0M3 T16 LU
HF 0M3 T12 LU
HF 0M3 T8 LU
HF 0M3 T6 LU
HF 0M3 T4 LU
HF 008 T24 LU
HF 008 T16 LU
HF 008 T12 LU
HF 008 T8 LU
HF 008 T6 LU
HF 008 T4 LU
Product Part Numbering
9.75
11.40
13.20
14.55
16.85
20.30
85
112
164
179
251
374 1000
1000
1000
1000
1000
1000 98
114
146
132
203
169
147
171
219
198
305
254
24 Fibre
16 Fibre
12 Fibre
8 Fibre
6 Fibre
4 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
LSZH Outer Sheath
LSZH Unit Sheath
Waterblocking Tape
Non Metallic Central Strength Member
Aramid Strength Members
900µm Tight Buffered Fibre
3 .12
Breakout Cables
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
LOOSE TUBE CABLES
MFOS loose tube cables are available in
unitube or multi loose tube constructions,
in three standard variants. Multi loose tube
cables are available as standard in 6 x 4 fibre
per tube, 6 x 12 fibre per tube and 12 x 12
fibre per tube options, offering up to
144 fibres.
The three standard variants are a general
duct grade cable; a glass yarn armoured
cable and a corrugated steel tape
armoured cable.
Loose tube cables are designed for use in
building or campus backbone applications
and can be installed by blowing, winching
or pulling into existing sub ducts or cable
conduits. Steel tape armoured products can
also be direct buried.
Bespoke loose tube cables to client
specifications with additional features or
modified mechanical performance are
available on request subject to MOQ
and lead-time.
3-13
Optical Systems
Compact Water Blocked Design
Up to 24 Fibres
Level 1 Rodent Protection
Choice of Universal or External Sheath
PRODUCT DESCRIPTION:
For building backbone applications, the
duct grade unitube cable range has been
designed to be lightweight and compact.
The 4-12 fibre product variants are
constructed around a 2.90mm gel filled
loose tube, whereas the 16-24 fibre variants
use a 4.00mm loose tube.
PRODUCT PERFORMANCE:
Crush (N):
2000
Impact (Nm):
15
Torsion (turns / m):
5
Fire:
IEC 60332-1 (UDU only)
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
63
3-14
Duct Grade Unitube Cables
LSZH or PE Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Water Blocking Glass Yarns
Individual Inked Fibres
HF 062 UNI24 LU
HF 062 UNI16 LU
HF 062 UNI12 LU
HF 062 UNI8 LU
HF 062 UNI6 LU
HF 062 UNI4 LU
12 Fibre
8 Fibre
6 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 UNI24 LU
HF 050 UNI16 LU
HF 050 UNI12 LU
HF 050 UNI8 LU
HF 050 UNI6 LU
HF 050 UNI4 LU
HF OM3 UNI24 LU
HF OM3 UNI16 LU
HF OM3 UNI12 LU
HF OM3 UNI8 LU
HF OM3 UNI6 LU
HF OM3 UNI4 LU
HF 008 UNI24 LU
HF 008 UNI16 LU
HF 008 UNI12 LU
HF 008 UNI8 LU
HF 008 UNI6 LU
HF 008 UNI4 LU
Product Part Numbering - UDU
16 Fibre(2 x Bundles)
24 Fibre(2 x Bundles)
HF 062 UNI24 NM
HF 062 UNI16 NM
HF 062 UNI12 NM
HF 062 UNI8 NM
HF 062 UNI6 NM
HF 062 UNI4 NM
12 Fibre
8 Fibre
6 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 UNI24 NM
HF 050 UNI16 NM
HF 050 UNI12 NM
HF 050 UNI8 NM
HF 050 UNI6 NM
HF 050 UNI4 NM
HF OM3 UNI24 NM
HF OM3 UNI16 NM
HF OM3 UNI12 NM
HF OM3 UNI8 NM
HF OM3 UNI6 NM
HF OM3 UNI4 NM
HF 008 UNI24 NM
HF 008 UNI16 NM
HF 008 UNI12 NM
HF 008 UNI8 NM
HF 008 UNI6 NM
HF 008 UNI4 NM
Product Part Numbering - UDE
16 Fibre(2 x Bundles)
24 Fibre(2 x Bundles)
MillenniuM Optical Cables - UDU and UDEDuct Grade Unitube Cables
6.90
6.90
6.90
6.90
7.80
7.80
51
51
51
51
63
63 700
700
700
700
700
700 69
69
69
69
78
78
104
104
104
104
117
117
12 Fibre
8 Fibre
6 Fibre
4 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
16 Fibre(2 x Bundles)
24 Fibre(2 x Bundles)
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
9.40
9.40
9.40
9.40
11.00
11.00
104
104
104
104
142
142 5000
5000
3000
3000
3000
3000 94
94
94
94
110
110
141
141
141
141
165
16516 Fibre(2 x Bundles)
24 Fibre(2 x Bundles)
12 Fibre
8 Fibre
6 Fibre
4 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
MillenniuM Optical Cables - URU and UREGlass Yarn Armoured Unitube Cable
Compact Water Blocked Design
Glass Yarn Armouring for
Rodent Resistance
Up to 24 fibres
Choice of Universal or External Sheath
PRODUCT DESCRIPTION:
For applications where protection from
rodent attack is required, this product range
offers level 2 rodent protection in the form
of glass roving armour which deters rodents
from chewing on optical cables.
The 4-12 fibre product variants are
constructed around a 2.90mm gel filled
loose tube, whereas the 16-24 fibre
variants use a 4.00mm loose tube.
PRODUCT PERFORMANCE:
Crush (N):
2500
Impact (Nm):
25
Torsion (turns / m):
5
Fire:
IEC 60332-1 (URU only)
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
HF 062 UNI24 (E) LU
HF 062 UNI16 (E) LU
HF 062 UNI12 (E) LU
HF 062 UNI8 (E) LU
HF 062 UNI6 (E) LU
HF 062 UNI4 (E) LU
12 Fibre
8 Fibre
6 Fibre
4 Fibre
16 Fibre(2 x Bundles)
24 Fibre(2 x Bundles)
62.5/125 50/125 OM3 8/125
HF 050 UNI24 (E) LU
HF 050 UNI16 (E) LU
HF 050 UNI12 (E) LU
HF 050 UNI8 (E) LU
HF 050 UNI6 (E) LU
HF 050 UNI4 (E) LU
HF OM3 UNI24 (E) LU
HF OM3 UNI16 (E) LU
HF OM3 UNI12 (E) LU
HF OM3 UNI8 (E) LU
HF OM3 UNI6 (E) LU
HF OM3 UNI4 (E) LU
HF 008 UNI24 (E) LU
HF 008 UNI16 (E) LU
HF 008 UNI12 (E) LU
HF 008 UNI8 (E) LU
HF 008 UNI6 (E) LU
HF 008 UNI4 (E) LU
Product Part Numbering - URU
3-15
Glass Armoured Unitube
LSZH or PE Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Rodent resistant Glass Yarn Armouring
Individual Inked Fibres
HF 062 UNI24 (E) NM
HF 062 UNI16 (E) NM
HF 062 UNI12 (E) NM
HF 062 UNI8 (E) NM
HF 062 UNI6 (E) NM
HF 062 UNI4 (E) NM
12 Fibre
8 Fibre
6 Fibre
4 Fibre
16 Fibre(2 x Bundles)
24 Fibre(2 x Bundles)
62.5/125 50/125 OM3 8/125
HF 050 UNI24 (E) NM
HF 050 UNI16 (E) NM
HF 050 UNI12 (E) NM
HF 050 UNI8 (E) NM
HF 050 UNI6 (E) NM
HF 050 UNI4 (E) NM
HF OM3 UNI24 (E) NM
HF OM3 UNI16 (E) NM
HF OM3 UNI12 (E) NM
HF OM3 UNI8 (E) NM
HF OM3 UNI6 (E) NM
HF OM3 UNI4 (E) NM
HF 008 UNI24 (E) NM
HF 008 UNI16 (E) NM
HF 008 UNI12 (E) NM
HF 008 UNI8 (E) NM
HF 008 UNI6 (E) NM
HF 008 UNI4 (E) NM
Product Part Numbering - URE
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
10.50
10.50
10.50
10.50
10.50
10.50
127
127
127
128
128
129 700
700
700
700
700
700 105
105
105
105
105
105
158
158
158
158
158
158
12 Fibre
8 Fibre
6 Fibre
4 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
16 Fibre(2 x Bundles)
24 Fibre(2 x Bundles)
MillenniuM Optical Cables - USU and USESteel Tape Armoured Unitube Cables
Steel Tape Armouring
Maximum Protection from Rodents
Choice of Universal or External Sheath
PRODUCT DESCRIPTION:
For direct burial campus backbone
applications, the steel tape armoured
unitube cable range has been designed to
be compact and yet offer excellent tensile
and crush performance making it suitable
for a wide range of applications.
All USU and USE steel tape armoured
unitube cables are constructed around the
4.00mm gel filled PBT loose buffer tube. The
16-24 fibre variants supplied with 2 bundles
within the loose tube.
PRODUCT PERFORMANCE:
Crush (N):
4000
Impact (Nm):
30
Torsion (turns / m):
5
Fire:
IEC 60332-1 (USU only)
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +80°c
Temp - Installation:
-10°c to +70°c
HF 062 UNI24 STA LU
HF 062 UNI16 STA LU
HF 062 UNI12 STA LU
HF 062 UNI8 STA LU
HF 062 UNI6 STA LU
HF 062 UNI4 STA LU
24 Fibre
16 Fibre
12 Fibre
8 Fibre
6 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 UNI24 STA LU
HF 050 UNI16 STA LU
HF 050 UNI12 STA LU
HF 050 UNI8 STA LU
HF 050 UNI6 STA LU
HF 050 UNI4 STA LU
HF OM3 UNI24 STA LU
HF OM3 UNI16 STA LU
HF OM3 UNI12 STA LU
HF OM3 UNI8 STA LU
HF OM3 UNI6 STA LU
HF OM3 UNI4 STA LU
HF 008 UNI24 STA LU
HF 008 UNI16 STA LU
HF 008 UNI12 STA LU
HF 008 UNI8 STA LU
HF 008 UNI6 STA LU
HF 008 UNI4 STA LU
Product Part Numbering - USU
3-16
Steel Tape Armoured
HF 062 UNI24 STA NM
HF 062 UNI16 STA NM
HF 062 UNI12 STA NM
HF 062 UNI8 STA NM
HF 062 UNI6 STA NM
HF 062 UNI4 STA NM
24 Fibre
16 Fibre
12 Fibre
8 Fibre
6 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 UNI24 STA NM
HF 050 UNI16 STA NM
HF 050 UNI12 STA NM
HF 050 UNI8 STA NM
HF 050 UNI6 STA NM
HF 050 UNI4 STA NM
HF OM3 UNI24 STA NM
HF OM3 UNI16 STA NM
HF OM3 UNI12 STA NM
HF OM3 UNI8 STA NM
HF OM3 UNI6 STA NM
HF OM3 UNI4 STA NM
HF 008 UNI24 STA NM
HF 008 UNI16 STA NM
HF 008 UNI12 STA NM
HF 008 UNI8 STA NM
HF 008 UNI6 STA NM
HF 008 UNI4 STA NM
Product Part Numbering - USE
LSZH or PE Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Glass Yarns
Individual Inked Fibres
Corrugated Steel Tape Armour
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
13.00
13.00
13.00
13.00
13.00
13.00
224
224
224
224
224
224 700
700
700
700
700
700 130
130
130
130
130
130
195
195
195
195
195
195
12 Fibre
8 Fibre
6 Fibre
4 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
16 Fibre(2 x Bundles)
24 Fibre(2 x Bundles)
HF 062 UNI24 NM STA NM
HF 062 UNI16 NM STA NM
HF 062 UNI12 NM STA NM
HF 062 UNI8 NM STA NM
HF 062 UNI6 NM STA NM
HF 062 UNI4 NM STA NM
24 Fibre
16 Fibre
12 Fibre
8 Fibre
6 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 UNI24 NM STA NM
HF 050 UNI16 NM STA NM
HF 050 UNI12 NM STA NM
HF 050 UNI8 NM STA NM
HF 050 UNI6 NM STA NM
HF 050 UNI4 NM STA NM
HF OM3 UNI24 NM STA NM
HF OM3 UNI16 NM STA NM
HF OM3 UNI12 NM STA NM
HF OM3 UNI8 NM STA NM
HF OM3 UNI6 NM STA NM
HF OM3 UNI4 NM STA NM
HF 008 UNI24 NM STA NM
HF 008 UNI16 NM STA NM
HF 008 UNI12 NM STA NM
HF 008 UNI8 NM STA NM
HF 008 UNI6 NM STA NM
HF 008 UNI4 NM STA NM
Product Part Numbering - USE2
MillenniuM Optical Cables - USU2 and USE2Twin Sheath Steel Tape Armoured Unitube Cables
Twin Sheath Water Blocked Design
Steel Tape Armouring
Maximum Rodent Product
Choice of Universal or External Sheath
PRODUCT DESCRIPTION:
For direct burial campus backbone
applications, the twin sheath universal steel
tape armoured unitube cable range has
been designed to be compact and yet offer
excellent tensile and crush performance
making it suitable for a wide range of
applications.
The 4-12 fibre product variants are
constructed around a 2.90mm gel filled
loose tube, whereas the 16-24 fibre variants
use a 4.00mm loose tube.
PRODUCT PERFORMANCE:
Crush (N):
5000
Impact (Nm):
30
Torsion (turns / m):
5
Fire:
IEC 60332-1 (USU2 only)
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +80°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
HF 062 UNI24 L STA LU
HF 062 UNI16 L STA LU
HF 062 UNI12 L STA LU
HF 062 UNI8 L STA LU
HF 062 UNI6 L STA LU
HF 062 UNI4 L STA LU
24 Fibre
16 Fibre
12 Fibre
8 Fibre
6 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 UNI24 L STA LU
HF 050 UNI16 L STA LU
HF 050 UNI12 L STA LU
HF 050 UNI8 L STA LU
HF 050 UNI6 L STA LU
HF 050 UNI4 L STA LU
HF OM3 UNI24 L STA LU
HF OM3 UNI16 L STA LU
HF OM3 UNI12 L STA LU
HF OM3 UNI8 L STA LU
HF OM3 UNI6 L STA LU
HF OM3 UNI4 L STA LU
HF 008 UNI24 L STA LU
HF 008 UNI16 L STA LU
HF 008 UNI12 L STA LU
HF 008 UNI8 L STA LU
HF 008 UNI6 L STA LU
HF 008 UNI4 L STA LU
Product Part Numbering - USU2
3-17
Optical Systems
LSZH or PE Outer Sheath
LSZH or PE Inner Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Glass Yarns
Individual Inked Fibres
Corrugated Steel Tape Armour
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
HF 062 S24 W LU
HF 062 S20 W LU
HF 062 S16 W LU
HF 062 S12 W LU
HF 062 S8 W LU
HF 062 S4 W LU
24 Fibre
20 Fibre
16 Fibre
12 Fibre
8 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S24 W LU
HF 050 S20 W LU
HF 050 S16 W LU
HF 050 S12 W LU
HF 050 S8 W LU
HF 050 S4 W LU
HF OM3 S24 W LU
HF OM3 S20 W LU
HF OM3 S16 W LU
HF OM3 S12 W LU
HF OM3 S8 W LU
HF OM3 S4 W LU
HF 008 S24 W LU
HF 008 S20 W LU
HF 008 S16 W LU
HF 008 S12 W LU
HF 008 S8 W LU
HF 008 S4 W LU
Product Part Numbering - MDU 01
10.00
10.00
10.00
10.00
10.00
10.00
96
96
96
96
96
96 1500
1500
1500
1500
1500
1500 100
100
100
100
100
100
150
150
150
150
150
150
24 Fibre
20 Fibre
16 Fibre
12 Fibre
8 Fibre
4 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
HF 062 S24 W NM
HF 062 S20 W NM
HF 062 S16 W NM
HF 062 S12 W NM
HF 062 S8 W NM
HF 062 S4 W NM
24 Fibre
20 Fibre
16 Fibre
12 Fibre
8 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S24 W NM
HF 050 S20 W NM
HF 050 S16 W NM
HF 050 S12 W NM
HF 050 S8 W NM
HF 050 S4 W NM
HF OM3 S24 W NM
HF OM3 S20 W NM
HF OM3 S16 W NM
HF OM3 S12 W NM
HF OM3 S8 W NM
HF OM3 S4 W NM
HF 008 S24 W NM
HF 008 S20 W NM
HF 008 S16 W NM
HF 008 S12 W NM
HF 008 S8 W NM
HF 008 S4 W NM
Product Part Numbering - MDE 01
MillenniuM Optical Cables - Universal MDU 01 and External MDE 01Duct Grade Multi Loose Tube Cable
3-18
Duct Grade Multi Loose Tube Cable
Rigid Glass Central Strength Member
Choice of Universal or External Sheath
6 x 4 Fibre Per Tube
Offering Up To 24 Fibres
2.10mm Gel Filled Loose Tube
PRODUCT DESCRIPTION:
For applications where a higher tensile
load is required versus that offered by
unitube constructions, the universal product
range offers compact low fibre count duct
grade cable. The product range consists
of multiple loose tubes containing up to
4 fibres and solid fillers where required,
stranded around a rigid glass non metallic
central strength member. A layer of water
blocking tape provides interstitial
water blocking.
PRODUCT PERFORMANCE:
Crush (N):
2500
Impact (Nm):
25
Torsion (turns / m):
5
Fire:
IEC 60332-1(MDU only)
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
LSZH or PE Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Individual Inked Fibres
Rigid Glass Central Strength Member
Water Blocking Tape
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
11.20
11.20
11.20
11.20
11.20
11.20
118
118
118
118
118
118 2000
2000
2000
2000
2000
2000 112
112
112
112
112
112
168
168
168
168
168
168
72 Fibre
60 Fibre
48 Fibre
36 Fibre
24 Fibre
12 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
MillenniuM Optical Cables - Universal MDU 02 and External MDE 02Universal Duct Grade Multi Loose Tube Cable
HF 062 S72 W LU
HF 062 S60 W LU
HF 062 S48 W LU
HF 062 S36 W LU
HF 062 S24 W LU
HF 062 S12 W LU
72 Fibre
60 Fibre
48 Fibre
36 Fibre
24 Fibre
12 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S72 W LU
HF 050 S60 W LU
HF 050 S48 W LU
HF 050 S36 W LU
HF 050 S24 W LU
HF 050 S12 W LU
HF OM3 S72 W LU
HF OM3 S60 W LU
HF OM3 S48 W LU
HF OM3 S36 W LU
HF OM3 S24 W LU
HF OM3 S12 W LU
HF 008 S72 W LU
HF 008 S60 W LU
HF 008 S48 W LU
HF 008 S36 W LU
HF 008 S24 W LU
HF 008 S12 W LU
Product Part Numbering - MDU 02
3-19
Duct Grade Multi Loose Tube Cable
Rigid Glass Central Strength Member
Choice of Universal or External Sheath
6 x 12 Fibre Per Tube
Offering Up To 72 Fibres
2.50mm Gel Filled Loose Tube
PRODUCT DESCRIPTION:
For building and campus backbone
applications where higher fibre counts
are required, the product range offers a
compact duct grade cable. The product
range consists of multiple loose tubes
containing up to 12 fibres and solid fillers
where required, stranded around a rigid
glass non metallic central strength member.
A layer of water blocking tape provides
interstitial water blocking.
PRODUCT PERFORMANCE:
Crush (N):
2500
Impact (Nm):
25
Torsion (turns / m):
5
Fire:
IEC 60332-1
(MDU only)
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
HF 062 S72 W NM
HF 062 S60 W NM
HF 062 S48 W NM
HF 062 S36 W NM
HF 062 S24 W NM
HF 062 S12 W NM
72 Fibre
60 Fibre
48 Fibre
36 Fibre
24 Fibre
12 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S72 W NM
HF 050 S60 W NM
HF 050 S48 W NM
HF 050 S36 W NM
HF 050 S24 W NM
HF 050 S12 W NM
HF OM3 S72 W NM
HF OM3 S60 W NM
HF OM3 S48 W NM
HF OM3 S36 W NM
HF OM3 S24 W NM
HF OM3 S12 W NM
HF 008 S72 W NM
HF 008 S60 W NM
HF 008 S48 W NM
HF 008 S36 W NM
HF 008 S24 W NM
HF 008 S12 W NM
Product Part Numbering - MDE 02
LSZH or PE Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Individual Inked Fibres
Rigid Glass Central Strength Member
Water Blocking Tape
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
MillenniuM Optical Cables - Universal MDU 03 and External MDE 03Duct Grade Multi Loose Tube Cable
HF 062 S144 W LU
HF 062 S132 W LU
HF 062 S120 W LU
HF 062 S108 W LU
HF 062 S96 W LU
144 Fibre
132 Fibre
120 Fibre
108 Fibre
96 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S144 W LU
HF 050 S132 W LU
HF 050 S120 W LU
HF 050 S108 W LU
HF 050 S96 W LU
HF OM3 S144 W LU
HF OM3 S132 W LU
HF OM3 S120 W LU
HF OM3 108 W LU
HF OM3 S96 W LU
HF 008 S144 W LU
HF 008 S132 W LU
HF 008 S120 W LU
HF 008 S108 W LU
HF 008 S96 W LU
Product Part Numbering - MDU 03
16.00
16.00
16.00
16.00
16.00
222
222
222
222
222 2000
2000
2000
2000
2000 160
160
160
160
160
240
240
240
240
240144 Fibre
132 Fibre
120 Fibre
108 Fibre
96 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
Duct Grade Multi Loose Tube Cable
Rigid Glass Central Strength Member
Choice of Universal or External Sheath
12 x 12 Fibre Per Tube
Offering Up To 144 Fibres
2.50mm Gel Filled Loose Tube
PRODUCT DESCRIPTION:
For higher fibre count building and campus
backbone applications the product range
delivers up to 144 fibres in a compact duct
grade construction. The product range
consists of multiple 2.50mm loose tubes
containing up to 12 fibres and solid fillers
where required, stranded around a sheathed
rigid glass non metallic central strength
member. A layer of water blocking tape
provides interstitial water blocking.
PRODUCT PERFORMANCE:
Crush (N):
2500
Impact (Nm):
25
Torsion (turns / m):
5
Fire:
IEC 60332-1
(MDU only)
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
HF 062 S144 W NM
HF 062 S132 W NM
HF 062 S120 W NM
HF 062 S108 W NM
HF 062 S96 W NM
144 Fibre
132 Fibre
120 Fibre
108 Fibre
96 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S144 W NM
HF 050 S132 W NM
HF 050 S120 W NM
HF 050 S108 W NM
HF 050 S96 W NM
HF OM3 S144 W NM
HF OM3 S132 W NM
HF OM3 S120 W NM
HF OM3 108 W NM
HF OM3 S96 W NM
HF 008 S144 W NM
HF 008 S132 W NM
HF 008 S120 W NM
HF 008 S108 W NM
HF 008 S96 W NM
Product Part Numbering - MDE 03
LSZH or PE Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Individual Inked Fibres
Water Blocking Tape
Central Strength Member Sheath
Rigid Glass Central Strength Member
3-20
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
MillenniuM Optical Cables - Universal MRU 01 and External MRE 01Glass Yarn Armoured Rodent Resistant Multi Loose Tube Cable
HF 062 S24 W (E) LU
HF 062 S20 W (E) LU
HF 062 S16 W (E) LU
HF 062 S12 W (E) LU
HF 062 S8 W (E) LU
HF 062 S4 W (E) LU
24 Fibre
20 Fibre
16 Fibre
12 Fibre
8 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S24 W (E) LU
HF 050 S20 W (E) LU
HF 050 S16 W (E) LU
HF 050 S12 W (E) LU
HF 050 S8 W (E) LU
HF 050 S4 W (E) LU
HF OM3 S24 W (E) LU
HF OM3 S20 W (E) LU
HF OM3 S16 W (E) LU
HF OM3 S12 W (E) LU
HF OM3 S8 W (E) LU
HF OM3 S4 W (E) LU
HF 008 S24 W (E) LU
HF 008 S20 W (E) LU
HF 008 S16 W (E) LU
HF 008 S12 W (E) LU
HF 008 S8 W (E) LU
HF 008 S4 W (E) LU
Product Part Numbering - MRU 01
12.00
12.00
12.00
12.00
12.00
12.00
149
149
149
149
149
149 9000
9000
9000
9000
9000
9000 120
120
120
120
120
120
180
180
180
180
180
180
24 Fibre
20 Fibre
16 Fibre
12 Fibre
8 Fibre
4 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
3-21
Glass Yarn Armoured Multi Loose Tube Cable
Glass Yarn Armouring
for Rodent Resistance
Rigid Glass Central Strength Member
Choice of Universal or External Sheath
2.10mm Gel Filled Loose Tube
PRODUCT DESCRIPTION:
For applications where protection from
rodent attack is required and a higher
tensile load is required, exists the universal
MRR product range offers rodent protection
in the form of glass roving armour which
deters rodents from chewing on optical
cables. The product range consists of
multiple 2.10mm loose tubes containing up
to 4 fibres and solid fillers where required,
stranded around a rigid glass non metallic
central strength member.
A layer of water blocking tape provides
interstitial water blocking.
PRODUCT PERFORMANCE:
Crush (N):
3000
Impact (Nm):
30
Torsion (turns / m):
5
Fire:
IEC 60332-1
(MIU only)
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
HF 062 S24 W (E) NM
HF 062 S20 W (E) NM
HF 062 S16 W (E) NM
HF 062 S12 W (E) NM
HF 062 S8 W (E) NM
HF 062 S4 W (E) NM
24 Fibre
20 Fibre
16 Fibre
12 Fibre
8 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S24 W (E) NM
HF 050 S20 W (E) NM
HF 050 S16 W (E) NM
HF 050 S12 W (E) NM
HF 050 S8 W (E) NM
HF 050 S4 W (E) NM
HF OM3 S24 W (E) NM
HF OM3 S20 W (E) NM
HF OM3 S16 W (E) NM
HF OM3 S12 W (E) NM
HF OM3 S8 W (E) NM
HF OM3 S4 W (E) NM
HF 008 S24 W (E) NM
HF 008 S20 W (E) NM
HF 008 S16 W (E) NM
HF 008 S12 W (E) NM
HF 008 S8 W (E) NM
HF 008 S4 W (E) NM
Product Part Numbering - MRE 01
LSZH or PE Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Rodent Resistant Glass Yarn Armouring
Individual Inked Fibres
Rigid Glass Central Strength Member
Water Blocking Tape
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
13.00
13.00
13.00
13.00
13.00
13.00
171
171
171
171
171
171 9500
9500
9500
9500
9500
9500 130
130
130
130
130
130
195
195
195
195
195
195
72 Fibre
60 Fibre
48 Fibre
36 Fibre
24 Fibre
12 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
Glass Yarn Armoured Multi Loose Tube Cable
MillenniuM Optical Cables - Universal MRU 02 and External MRE 02Glass Yarn Armoured Rodent Resistant Multi Loose Tube Cable
HF 062 S72 W (E) LU
HF 062 S60 W (E) LU
HF 062 S48 W (E) LU
HF 062 S36 W (E) LU
HF 062 S24 W (E) LU
HF 062 S12 W (E) LU
72 Fibre
60 Fibre
48 Fibre
36 Fibre
24 Fibre
12 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S72 W (E) LU
HF 050 S60 W (E) LU
HF 050 S48 W (E) LU
HF 050 S36 W (E) LU
HF 050 S24 W (E) LU
HF 050 S12 W (E) LU
HF OM3 S72 W (E) LU
HF OM3 S60 W (E) LU
HF OM3 S48 W (E) LU
HF OM3 S36 W (E) LU
HF OM3 S24 W (E) LU
HF OM3 S12 W (E) LU
HF 008 S72 W (E) LU
HF 008 S60 W (E) LU
HF 008 S48 W (E) LU
HF 008 S36 W (E) LU
HF 008 S24 W (E) LU
HF 008 S12 W (E) LU
Product Part Numbering - MRU 02
3-22
Glass Yarn Armouring
for Rodent Resistance
Rigid Glass Central Strength Member
Choice of Universal or External Sheath
2.50mm Gel Filled Loose Tube
PRODUCT DESCRIPTION:
For applications where protection from
rodent attack and higher fibre counts are
required, the universal product range offers
rodent protection in the form of glass roving
armour which deters rodents from chewing
on optical cables. The product range
consists of multiple 2.50mm loose tubes
containing up to 12 fibres and solid fillers
where required, stranded around a rigid
glass non metallic central strength member.
A layer of water blocking tape provides
interstitial water blocking.
PRODUCT PERFORMANCE:
Crush (N):
3000
Impact (Nm):
30
Torsion (turns / m):
5
Fire:
IEC 60332-1
(MRU only)
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
LSZH Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Rodent Resistant Glass Yarn Armouring
Individual Inked Fibres
Rigid Glass Central Strength Member
Water Blocking Tape
HF 062 S72 W (E) NM
HF 062 S60 W (E) NM
HF 062 S48 W (E) NM
HF 062 S36 W (E) NM
HF 062 S24 W (E) NM
HF 062 S12 W (E) NM
72 Fibre
60 Fibre
48 Fibre
36 Fibre
24 Fibre
12 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S72 W (E) NM
HF 050 S60 W (E) NM
HF 050 S48 W (E) NM
HF 050 S36 W (E) NM
HF 050 S24 W (E) NM
HF 050 S12 W (E) NM
HF OM3 S72 W (E) NM
HF OM3 S60 W (E) NM
HF OM3 S48 W (E) NM
HF OM3 S36 W (E) NM
HF OM3 S24 W (E) NM
HF OM3 S12 W (E) NM
HF 008 S72 W (E) NM
HF 008 S60 W (E) NM
HF 008 S48 W (E) NM
HF 008 S36 W (E) NM
HF 008 S24 W (E) NM
HF 008 S12 W (E) NM
Product Part Numbering - MRE 02
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
MillenniuM Optical Cables - Universal MRU 03 and External MRE 03Glass Yarn Armoured Rodent Resistant Multi Loose Tube Cable
HF 062 S144 W (E) LU
HF 062 S132 W (E) LU
HF 062 S120 W (E) LU
HF 062 S108 W (E) LU
HF 062 S96 W (E) LU
144 Fibre
132 Fibre
120 Fibre
108 Fibre
96 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S144 W (E) LU
HF 050 S132 W (E) LU
HF 050 S120 W (E) LU
HF 050 S108 W (E) LU
HF 050 S96 W (E) LU
HF OM3 S144 W (E) LU
HF OM3 S132 W (E) LU
HF OM3 S120 W (E) LU
HF OM3 S108 W (E) LU
HF OM3 S96 W (E) LU
HF 008 S144 W (E) LU
HF 008 S132 W (E) LU
HF 008 S120 W (E) LU
HF 008 S108 W (E) LU
HF 008 S96 W (E) LU
Product Part Numbering - MRU 03
17.40
17.40
17.40
17.40
17.40
279
279
279
279
279 10500
10500
10500
10500
10500 174
174
174
174
174
261
261
261
261
261144 Fibre
132 Fibre
120 Fibre
108 Fibre
96 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
3-23
Glass Yarn Armouring
for Rodent Resistance
Rigid Glass Central Strength Member
Choice of Universal or External Sheath
12 x 12 Fibre Per Tube
Offering Up To 144 Fibres
2.50mm Gel Filled Loose Tube
PRODUCT DESCRIPTION:
For applications where protection from
rodent attack and higher fibre counts are
required, the universal product range offers
rodent protection in the form of glass roving
armour that deters rodents from chewing on
optical cables. The product range consists of
multiple 2.50mm loose tubes containing up
to 12 fibres and solid fillers where required,
stranded around a sheathed rigid glass non
metallic central strength member. A layer
of water blocking tape provides interstitial
water blocking.
PRODUCT PERFORMANCE:
Crush (N):
3000
Impact (Nm):
30
Torsion (turns / m):
5
Fire:
IEC 60332-1
(MRU only)
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
LSZH Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Rodent Resistant Glass Yarn Armouring
Individual Inked Fibres
Central Strength Member Sheath
Rigid Glass Central Strength Member
Water Blocking Tape
Glass Yarn Armoured Multi Loose Tube Cable
HF 062 S144 W (E) NM
HF 062 S132 W (E) NM
HF 062 S120 W (E) NM
HF 062 S108 W (E) NM
HF 062 S96 W (E) NM
144 Fibre
132 Fibre
120 Fibre
108 Fibre
96 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S144 W (E) NM
HF 050 S132 W (E) NM
HF 050 S120 W (E) NM
HF 050 S108 W (E) NM
HF 050 S96 W (E) NM
HF OM3 S144 W (E) NM
HF OM3 S132 W (E) NM
HF OM3 S120 W (E) NM
HF OM3 S108 W (E) NM
HF OM3 S96 W (E) NM
HF 008 S144 W (E) NM
HF 008 S132 W (E) NM
HF 008 S120 W (E) NM
HF 008 S108 W (E) NM
HF 008 S96 W (E) NM
Product Part Numbering - MRE 03
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
MillenniuM Optical Cables - Universal MSU 01 and External MSE 01Direct Burial Steel Tape Armoured Multi Loose Tube Cable
HF 062 S24 W STA LU
HF 062 S20 W STA LU
HF 062 S16 W STA LU
HF 062 S12 W STA LU
HF 062 S8 W STA LU
HF 062 S4 W STA LU
24 Fibre
20 Fibre
16 Fibre
12 Fibre
8 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S24 W STA LU
HF 050 S20 W STA LU
HF 050 S16 W STA LU
HF 050 S12 W STA LU
HF 050 S8 W STA LU
HF 050 S4 W STA LU
HF OM3 S24 W STA LU
HF OM3 S20 W STA LU
HF OM3 S16 W STA LU
HF OM3 S12 W STA LU
HF OM3 S8 W STA LU
HF OM3 S4 W STA LU
HF 008 S24 W STA LU
HF 008 S20 W STA LU
HF 008 S16 W STA LU
HF 008 S12 W STA LU
HF 008 S8 W STA LU
HF 008 S4 W STA LU
Product Part Numbering - MSU 01
12.20
12.20
12.20
12.20
12.20
12.20
190
190
190
190
190
190 1500
1500
1500
1500
1500
1500 122
122
122
122
122
122
183
183
183
183
183
183
24 Fibre
20 Fibre
16 Fibre
12 Fibre
8 Fibre
4 Fibre
Diameter
mm
Weight
kg/km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
3-24
HF 062 S24 W STA NM
HF 062 S20 W STA NM
HF 062 S16 W STA NM
HF 062 S12 W STA NM
HF 062 S8 W STA NM
HF 062 S4 W STA NM
24 Fibre
20 Fibre
16 Fibre
12 Fibre
8 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S24 W STA NM
HF 050 S20 W STA NM
HF 050 S16 W STA NM
HF 050 S12 W STA NM
HF 050 S8 W STA NM
HF 050 S4 W STA NM
HF OM3 S24 W STA NM
HF OM3 S20 W STA NM
HF OM3 S16 W STA NM
HF OM3 S12 W STA NM
HF OM3 S8 W STA NM
HF OM3 S4 W STA NM
HF 008 S24 W STA NM
HF 008 S20 W STA NM
HF 008 S16 W STA NM
HF 008 S12 W STA NM
HF 008 S8 W STA NM
HF 008 S4 W STA NM
Product Part Numbering - MSE 01
Steel Tape Armoured Multi Loose Tube Cable
LSZH or PE Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Corrugated Steel Tape Armour
Individual Inked Fibres
Rigid Glass Central Strength Member
Water Blocking Tape
Corrugated Steel Tape Armour
Rigid Glass Central Strength Member
Choice of Universal or External Sheath
6 x 4 Fibre Per Tube
Offering Up To 24 Fibres
2.10mm Gel Filled Loose Tube
PRODUCT DESCRIPTION:
For applications where a higher tensile load
is required versus that offered by unitube
constructions, this product range offers
a compact low fibre count direct burial
grade cable. The product range consists of
multiple 2.10mm loose tubes containing up
to 4 fibres and solid fillers where required,
stranded around a rigid glass non metallic
central strength member. A layer of water
blocking tape provides interstitial water
blocking and a layer of corrugated steel tape
armour provides additional crush resistance.
PRODUCT PERFORMANCE:
Crush(N):
7500
Impact(Nm):
30
Torsion(turns/m):
5
Fire:
IEC 60332-1
(MSU only)
Temp-Operation:
-40°c to +70°c
Temp-Storage:
-40°c to +70°c
Temp-Installation:
-10°c to +70°c
WaterPenetration:
<3m @ 24h
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
HF 062 S72 W STA NM
HF 062 S60 W STA NM
HF 062 S48 W STA NM
HF 062 S36 W STA NM
HF 062 S24 W STA NM
HF 062 S12 W STA NM
72 Fibre
60 Fibre
48 Fibre
36 Fibre
24 Fibre
12 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S72 W STA NM
HF 050 S60 W STA NM
HF 050 S48 W STA NM
HF 050 S36 W STA NM
HF 050 S24 W STA NM
HF 050 S12 W STA NM
HF OM3 S72 W STA NM
HF OM3 S60 W STA NM
HF OM3 S48 W STA NM
HF OM3 S36 W STA NM
HF OM3 S24 W STA NM
HF OM3 S12 W STA NM
HF 008 S72 W STA NM
HF 008 S60 W STA NM
HF 008 S48 W STA NM
HF 008 S36 W STA NM
HF 008 S24 W STA NM
HF 008 S12 W STA NM
Product Part Numbering - MSE 02
MillenniuM Optical Cables - Universal MSU 02 and MSE 02Direct Burial Steel Tape Armoured Multi Loose Tube Cable
HF 062 S72 W STA LU
HF 062 S60 W STA LU
HF 062 S48 W STA LU
HF 062 S36 W STA LU
HF 062 S24 W STA LU
HF 062 S12 W STA LU
72 Fibre
60 Fibre
48 Fibre
36 Fibre
24 Fibre
12 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S72 W STA LU
HF 050 S60 W STA LU
HF 050 S48 W STA LU
HF 050 S36 W STA LU
HF 050 S24 W STA LU
HF 050 S12 W STA LU
HF OM3 S72 W STA LU
HF OM3 S60 W STA LU
HF OM3 S48 W STA LU
HF OM3 S36 W STA LU
HF OM3 S24 W STA LU
HF OM3 S12 W STA LU
HF 008 S72 W STA LU
HF 008 S60 W STA LU
HF 008 S48 W STA LU
HF 008 S36 W STA LU
HF 008 S24 W STA LU
HF 008 S12 W STA LU
Product Part Numbering - MSU 02
13.40
13.40
13.40
13.40
13.40
13.40
227
227
227
227
227
227 2000
2000
2000
2000
2000
2000 134
134
134
134
134
134
201
201
201
201
201
201
72 Fibre
60 Fibre
48 Fibre
36 Fibre
24 Fibre
12 Fibre
Diameter
mm
Weight
kg/km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
3-25
Steel Tape Armoured Multi Loose Tube Cable
Corrugated Steel Tape Armour.
Rigid Glass Central Strength Member
Choice of Universal or External Sheath
6 x 12 Fibre Per Tube
Offering Up To 72 Fibres
2.50mm Gel Filled Loose Tube
PRODUCT DESCRIPTION:
For direct burial applications, the single
sheathed product range offers up to 72
fibres in a compact and relatively flexible
construction. The product range consists of
multiple 2.50mm loose tubes containing up
to 12 fibres and solid fillers where required,
stranded around a rigid glass non metallic
central strength member.
A layer of water blocking tape provides
interstitial water blocking and a layer of
steel tape armour provides additional crush
resistance.
PRODUCT PERFORMANCE:
Crush(N):
7500
Impact(Nm):
30
Torsion(turns/m):
5
Fire:
IEC 60332-1
(MSU only)
Temp-Operation:
-40°c to +70°c
Temp-Storage:
-40°c to +70°c
Temp-Installation:
-10°c to +70°c
WaterPenetration:
<3m @ 24h
LSZH or PE Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Corrugated Steel Tape Armour
Individual Inked Fibres
Rigid Glass Central Strength Member
Water Blocking Tape
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
MillenniuM Optical Cables - Universal MSU 03 and External MSE 03Direct Burial Steel Tape Armoured Multi Loose Tube cable
HF 062 S144 W STA LU
HF 062 S132 W STA LU
HF 062 S120 W STA LU
HF 062 S108 W STA LU
HF 062 S96 W STA LU
144 Fibre
132 Fibre
120 Fibre
108 Fibre
96 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S144 W STA LU
HF 050 S132 W STA LU
HF 050 S120 W STA LU
HF 050 S108 W STA LU
HF 050 S96 W STA LU
HF OM3 S144 W STA LU
HF OM3 S132 W STA LU
HF OM3 S120 W STA LU
HF OM3 S108 W STA LU
HF OM3 S96 W STA LU
HF 008 144 W STA LU
HF 008 S132 W STA LU
HF 008 S120 W STA LU
HF 008 S108 W STA LU
HF 008 S96 W STA LU
Product Part Numbering - MSU 03
18.20
18.20
18.20
18.20
18.20
372
372
372
372
372 2000
2000
2000
2000
2000 182
182
182
182
182
273
273
273
273
273144 Fibre
132 Fibre
120 Fibre
108 Fibre
96 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
3-26
Steel Tape Armoured Multi Loose Tube Cable
Corrugated Steel Tape Armour
Rigid Glass Central Strength Member
Choice of Universal or External Sheath
12 x 12 Fibre Per Tube
Offering Up To 144 Fibres
2.50mm Gel Filled Loose Tube
PRODUCT DESCRIPTION:
For direct burial applications, the single
sheathed product range offers up to 144
fibres in a compact and relatively flexible
construction. The product range consists of
multiple 2.50mm loose tubes containing up
to 12 fibres and solid fillers where required,
stranded around a sheathed rigid glass non
metallic central strength member. A layer
of water blocking tape provides interstitial
water blocking and a layer of corrugated
steel tape armour gives additional
crush resistance.
PRODUCT PERFORMANCE:
Crush (N):
7500
Impact (Nm):
30
Torsion (turns / m):
5
Fire:
IEC 60332-1
(MSU only)
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24hHF 062 S144 W STA NM
HF 062 S132 W STA NM
HF 062 S120 W STA NM
HF 062 S108 W STA NM
HF 062 S96 W STA NM
144 Fibre
132 Fibre
120 Fibre
108 Fibre
96 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S144 W STA NM
HF 050 S132 W STA NM
HF 050 S120 W STA NM
HF 050 S108 W STA NM
HF 050 S96 W STA NM
HF OM3 S144 W STA NM
HF OM3 S132 W STA NM
HF OM3 S120 W STA NM
HF OM3 S108 W STA NM
HF OM3 S96 W STA NM
HF 008 144 W STA NM
HF 008 S132 W STA NM
HF 008 S120 W STA NM
HF 008 S108 W STA NM
HF 008 S96 W STA NM
Product Part Numbering - MSE 03
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
LSZH Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Corrugated Steel Tape Armour
Individual Inked Fibres
Central Strength Member Sheath
Rigid Glass Central Strength Member
Water Blocking Tape
MillenniuM Optical Cables - Universal MSU2 01 and External MSE2 01Burial Steel Tape Armoured Multi Loose Tube Cable
HF 062 S24 W L STA LU
HF 062 S20 W L STA LU
HF 062 S16 W L STA LU
HF 062 S12 W L STA LU
HF 062 S8 W L STA LU
HF 062 S4 W L STA LU
24 Fibre
20 Fibre
16 Fibre
12 Fibre
8 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S24 W L STA LU
HF 050 S20 W L STA LU
HF 050 S16 W L STA LU
HF 050 S12 W L STA LU
HF 050 S8 W L STA LU
HF 050 S4 W L STA LU
HF OM3 S24 W L STA LU
HF OM3 S20 W L STA LU
HF OM3 S16 W L STA LU
HF OM3 S12 W L STA LU
HF OM3 S8 W L STA LU
HF OM3 S4 W L STA LU
HF 008 S24 W L STA LU
HF 008 S20 W L STA LU
HF 008 S16 W L STA LU
HF 008 S12 W L STA LU
HF 008 S8 W L STA LU
HF 008 S4 W L STA LU
Product Part Numbering - MSU2 01
14.1
14.1
14.1
14.1
14.1
14.1
247
247
247
247
247
247 2000
2000
2000
2000
2000
2000 145
145
145
145
145
145
215
215
215
215
215
215
24 Fibre
20 Fibre
16 Fibre
12 Fibre
8 Fibre
4 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
3-27
Corrugated Steel Tape Armour
Rigid Glass Central Strength Member
Choice of Universal or External Sheath
6 x 4 Fibre Per Tube
Offering Up To 24 Fibres
2.10mm Gel filled Loose Tube
PRODUCT DESCRIPTION:
For applications where a higher tensile load
is required versus that offered by unitube
constructions, the universal product range
offers a compact low fibre count direct
burial grade cable. The product range
consists of multiple 2.10mm loose tubes
containing up to 4 fibres and solid fillers
where required, stranded around a rigid
glass non metallic central strength member.
A layer of water blocking tape provides
interstitial water blocking and the LSZH or
PE inner sheath and a layer of corrugated
steel tape armour provide additional
crush resistance.
PRODUCT PERFORMANCE:
Crush (N):
7500
Impact (Nm):
30
Torsion (turns / m):
5
Fire:
IEC 60332-1
(MSU2 only)
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
LSZH or PE Outer Sheath
LSZH Inner Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Corrugated Steel Tape Armour
Individual Inked Fibres
Rigid Glass Central Strength Member
Water Blocking Tape
Steel Armoured Multi Loose Tube Cable
62.5/125 50/125 OM3 8/125
HF 062 S24 W NM STA NM
HF 062 S20 W NM STA NM
HF 062 S16 W NM STA NM
HF 062 S12 W NM STA NM
HF 062 S8 W NM STA NM
HF 062 S4 W NM STA NM
24 Fibre
20 Fibre
16 Fibre
12 Fibre
8 Fibre
4 Fibre
HF 050 S24 W NM STA NM
HF 050 S20 W NM STA NM
HF 050 S16 W NM STA NM
HF 050 S12 W NM STA NM
HF 050 S8 W NM STA NM
HF 050 S4 W NM STA NM
HF OM3 S24 W NM STA NM
HF OM3 S20 W NM STA NM
HF OM3 S16 W NM STA NM
HF OM3 S12 W NM STA NM
HF OM3 S8 W NM STA NM
HF OM3 S4 W NM STA NM
HF 008 S24 W NM STA NM
HF 008 S20 W NM STA NM
HF 008 S16 W NM STA NM
HF 008 S12 W NM STA NM
HF 008 S8 W NM STA NM
HF 008 S4 W NM STA NM
Product Part Numbering - MSE2 01
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
MillenniuM Optical Cables - Universal MSU2 02 and External MSE2 02Universal Direct Burial Steel Tape Armoured Multi Loose Tube Cable
HF 062 S72 W L STA LU
HF 062 S60 W L STA LU
HF 062 S48 W L STA LU
HF 062 S36 W L STA LU
HF 062 S24 W L STA LU
HF 062 S12 W L STA LU
72 Fibre
60 Fibre
48 Fibre
36 Fibre
24 Fibre
12 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S72 W L STA LU
HF 050 S60 W L STA LU
HF 050 S48 W L STA LU
HF 050 S36 W L STA LU
HF 050 S24 W L STA LU
HF 050 S12 W L STA LU
HF OM3 S72 W L STA LU
HF OM3 S60 W L STA LU
HF OM3 S48 W L STA LU
HF OM3 S36 W L STA LU
HF OM3 S24 W L STA LU
HF OM3 S12 W L STA LU
HF 008 S72 W L STA LU
HF 008 S60 W L STA LU
HF 008 S48 W L STA LU
HF 008 S36 W L STA LU
HF 008 S24 W L STA LU
HF 008 S12 W L STA LU
Product Part Numbering - MSU2 02
15.30
15.30
15.30
15.30
15.30
15.30
284
284
284
284
284
284 2000
2000
2000
2000
2000
2000 153
153
153
153
153
153
230
230
230
230
230
230
72 Fibre
60 Fibre
48 Fibre
36 Fibre
24 Fibre
12 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
3-28
Corrugated Steel Tape Armour
Rigid Glass Central Strength Member
Choice of Universal or External Sheath
6 x 12 Fibre Per Tube
Offering Up To 72 Fibres
2.50mm Gel Filled Loose Tube
PRODUCT DESCRIPTION:
For direct burial applications, the single
sheathed product range offers up to 72
fibres in a compact and relatively flexible
construction. The product range consists of
multiple 2.50mm loose tubes containing up
to 12 fibres and solid fillers where required,
stranded around a rigid glass non metallic
central strength member. A layer of water
blocking tape provides interstitial water
blocking and LSZH inner sheath and a layer
of corrugated steel tape armour provides
additional crush resistance.
PRODUCT PERFORMANCE:
Crush (N):
7500
Impact (Nm):
30
Torsion (turns / m):
5
Fire:
IEC 60332-1
(MSU2 only)
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
Outer LSZH Sheath
Inner LSZH Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Corrugated Steel Tape Armour
Individual Inked Fibres
Rigid Glass Central Strength Member
Water Blocking Tape
Steel Tape Armoured Multi Loose Tube Cable
HF 062 S72 WNM STA NM
HF 062 S60 WNM STA NM
HF 062 S48 WNM STA NM
HF 062 S36 WNM STA NM
HF 062 S24 WNM STA NM
HF 062 S12 WNM STA NM
72 Fibre
60 Fibre
48 Fibre
36 Fibre
24 Fibre
12 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S72 WNM STA NM
HF 050 S60 WNM STA NM
HF 050 S48 WNM STA NM
HF 050 S36 WNM STA NM
HF 050 S24 WNM STA NM
HF 050 S12 WNM STA NM
HF OM3 S72 WNM STA NM
HF OM3 S60 WNM STA NM
HF OM3 S48 WNM STA NM
HF OM3 S36 WNM STA NM
HF OM3 S24 WNM STA NM
HF OM3 S12 WNM STA NM
HF 008 S72 WNM STA NM
HF 008 S60 WNM STA NM
HF 008 S48 WNM STA NM
HF 008 S36 WNM STA NM
HF 008 S24 WNM STA NM
HF 008 S12 WNM STA NM
Product Part Numbering - MSE2 02
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
MillenniuM Optical Cables - Universal MSU2 03 and External MSE2 03Direct Burial Steel Tape Armoured Multi Loose Tube cable
HF 062 S144 W L STA LU
HF 062 S132 W L STA LU
HF 062 S120 W L STA LU
HF 062 S108 W L STA LU
HF 062 S96 W L STA LU
144 Fibre
132 Fibre
120 Fibre
108 Fibre
96 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S144 W L STA LU
HF 050 S132 W L STA LU
HF 050 S120 W L STA LU
HF 050 S108 W L STA LU
HF 050 S96 W L STA LU
HF OM3 S144 W L STA LU
HF OM3 S132 W L STA LU
HF OM3 S108 W L STA LU
HF OM3 S96 W L STA LU
HF 008 144 W L STA LU
HF 008 S132 W L STA LU
HF 008 S120 W L STA LU
HF 008 S108 W L STA LU
HF 008 S96 W L STA LU
Product Part Numbering - MSU2 03
20.00
20.00
20.00
20.00
20.00
445
445
445
445
445 2000
2000
2000
2000
2000 200
200
200
200
200
300
300
300
300
300144 Fibre
132 Fibre
120 Fibre
108 Fibre
96 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
3-29
Corrugated Steel Tape Armour
Rigid Glass Central Strength Member
Choice of Universal or External Sheath
12 x 12 Fibre Per Tube
Offering Up To 144 Fibres
2.50mm Gel Filled Loose Tube
PRODUCT DESCRIPTION:
For direct burial applications, the single
sheathed product range offers up to 144
fibres in a compact and relatively flexible
construction. The range consists of multiple
2.50mm loose tubes containing up to 12
fibres and solid fillers where required,
stranded around a sheathed rigid glass non
metallic central strength member. A layer
of water blocking tape provides interstitial
water blocking, a LSZH inner sheath and
a layer of corrugated steel tape armour
provides additional crush resistance.
PRODUCT PERFORMANCE:
Crush(N):
7500
Impact(Nm):
30
Torsion(turns/m):
5
Fire:
IEC60332-1
(MSUonly)
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
Outer LSZH or PE Sheath
Inner LSZH Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Corrugated Steel Tape Armour
Individual Inked Fibres
Central Strength Member Sheath
Rigid Glass Central Strength Member
Water Blocking Tape
Steel Tape Armoured Multi Loose Tube Cable
HF 062 S144 W NM STA NM
HF 062 S132 W NM STA NM
HF 062 S120 W NM STA NM
HF 062 S108 W NM STA NM
HF 062 S96 W NM STA NM
144 Fibre
132 Fibre
120 Fibre
108 Fibre
96 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S144 W NM STA NM
HF 050 S132 W NM STA NM
HF 050 S120 W NM STA NM
HF 050 S108 W NM STA NM
HF 050 S96 W NM STA NM
HF OM3 S144 W NM STA NM
HF OM3 S132 W NM STA NM
HF OM3 S120 W NM STA NM
HF OM3 S108 W NM STA NM
HF OM3 S96 W NM STA NM
HF 008 144 W NM STA NM
HF 008 S132 W NM STA NM
HF 008 S120 W NM STA NM
HF 008 S108 W NM STA NM
HF 008 S96 W NM STA NM
Product Part Numbering - MSE2 03
HF OM3 S120 W L STA LU
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
MillenniuM Optical Cables - External MAE 01External Duct Grade Cable with Aluminium Moisture Barrier
HF 062 S24 WMB
HF 062 S20 WMB
HF 062 S16 WMB
HF 062 S12 WMB
HF 062 S8 WMB
HF 062 S4 WMB
24 Fibre
20 Fibre
16 Fibre
12 Fibre
8 Fibre
4 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S24 WMB
HF 050 S20 WMB
HF 050 S16 WMB
HF 050 S12 WMB
HF 050 S8 WMB
HF 050 S4 WMB
HF OM3 S24 WMB
HF OM3 S20 WMB
HF OM3 S16 WMB
HF OM3 S12 WMB
HF OM3 S8 WMB
HF OM3 S4 WMB
HF 008 S24 WMB
HF 008 S20 WMB
HF 008 S16 WMB
HF 008 S12 WMB
HF 008 S8 WMB
HF 008 S4 WMB
Product Part Numbering - MAE 01
10.70
10.70
10.70
10.70
10.70
10.70
98
98
98
98
98
98 1500
1500
1500
1500
1500
1500 110
110
110
110
110
110
165
165
165
165
165
165
24 Fibre
20 Fibre
16 Fibre
12 Fibre
8 Fibre
4 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
3-30
Coated Aluminium Moisture Barrier
Rigid Glass Central Strength Member
Polyethylene Sheath
2.10mm Gel Filled Loose Tube
PRODUCT DESCRIPTION:
For applications where a traditional
moisture barrier is required, the external
product range offers moisture penetration
protection using a polyethylene coated
aluminium tape.
The product range consists of multiple
2.10mm loose tubes containing up to
4 fibres per tube and solid fillers where
required, stranded around a rigid glass
non metallic strength member. A layer of
waterblocking tape provides interstitial
waterblocking under the coated aluminium
moisture barrier tape.
PRODUCT PERFORMANCE:
Crush (N):
2500
Impact (Nm):
25
Torsion (turns / m):
5
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
Polyethylene Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Al/PE Moisture Barrier
Individual Inked Fibres
Rigid Glass Central Strength Member
Water Blocking Tape
Duct Grade Cable with Moisture Barrier
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
MillenniuM Optical Cables - External MAE 02External Duct Grade Cable with Aluminium Moisture Barrier
11.90
11.90
HF 062 S72 WMB
HF 062 S60 WMB
HF 062 S48 WMB
HF 062 S36 WMB
HF 062 S24 WMB
HF 062 S12 WMB
72 Fibre
60 Fibre
48 Fibre
36 Fibre
24 Fibre
12 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S72 WMB
HF 050 S60 WMB
HF 050 S48 WMB
HF 050 S36 WMB
HF 050 S24 WMB
HF 050 S12 WMB
HF OM3 S72 WMB
HF OM3 S60 WMB
HF OM3 S48 WMB
HF OM3 S36 WMB
HF OM3 S24 WMB
HF OM3 S12 WMB
HF 008 S72 WMB
HF 008 S60 WMB
HF 008 S48 WMB
HF 008 S36 WMB
HF 008 S24 WMB
HF 008 S12 WMB
Product Part Numbering - MAE 02
11.90
11.90
11.90
11.90
122
122
122
122
122
122 2000
2000
2000
2000
2000
2000 120
120
120
120
120
120
180
180
180
180
180
180
72 Fibre
60 Fibre
48 Fibre
36 Fibre
24 Fibre
12 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
3-31
Duct Grade Cable with Moisture Barrier
Coated Aluminium Moisture Barrier
Rigid Glass Central Strength Member
Polyethylene Sheath
2.50mm Gel Filled Loose Tube
PRODUCT DESCRIPTION:
For applications where a traditional
moisture barrier is required the external
MAB 06 product range offers moisture
penetration protection using a polyethylene
coated aluminium tape.
The MAB 06 product range consists of
multiple 2.50mm loose tubes containing
up to 12 fibres per tube and solid fillers
where required, stranded around a rigid
glass non metallic strength member. A layer
of waterblocking tape provides interstitial
waterblocking under the coated aluminium
moisture barrier tape. All MAB 06 product
have a Polyethylene sheath making them
suitable for external applications.
PRODUCT PERFORMANCE:
Crush (N):
2500
Impact (Nm):
25
Torsion (turns / m):
5
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
Polyethylene Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Al/PE Moisture Barrier
Individual Inked Fibres
Rigid Glass Central Strength Member
Water Blocking Tape
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
MillenniuM Optical Cables - External MAE 03External Duct Grade Cable with Aluminium Moisture Barrier
HF 062 S144 WMB
HF 062 S132 WMB
HF 062 S120 WMB
HF 062 S108 WMB
HF 062 S96 WMB
144 Fibre
132 Fibre
120 Fibre
108 Fibre
96 Fibre
62.5/125 50/125 OM3 8/125
HF 050 S144 WMB
HF 050 S132 WMB
HF 050 S120 WMB
HF 050 S108 WMB
HF 050 S96 WMB
HF OM3 S144 WMB
HF OM3 S132 WMB
HF OM3 S120 WMB
HF OM3 S108 WMB
HF OM3 S96 WMB
HF 008 S144 WMB
HF 008 S132 WMB
HF 008 S120 WMB
HF 008 S108 WMB
HF 008 S96 WMB
Product Part Numbering MAE 03
16.70
16.70
16.70
16.70
16.70
231
231
231
231
231 2500
2500
2500
2500
2500 170
170
170
170
170
250
250
250
250
250144 Fibre
132 Fibre
120 Fibre
108 Fibre
96 Fibre
Diameter
mm
Weight
kg / km
Max Tensile Load
N
Min Static Bendmm
Min Dynamic Bendmm
Product Data
3-32
Duct Grade Cable with Moisture Barrier
Coated Aluminium Moisture Barrier
Rigid Glass Central Strength Member
Polyethylene Sheath
2.50mm Gel Filled Loose Tube
PRODUCT DESCRIPTION:
For applications where a traditional moisture
barrier is required, the product range offers
moisture penetration protection using a
polyethylene coated aluminium tape.
The product range consists of multiple
2.50mm loose tubes containing up to
12 fibres per tube and solid fillers where
required, stranded around a rigid glass
non metallic strength member. A layer of
waterblocking tape provides interstitial
waterblocking under the coated aluminium
moisture barrier tape.
PRODUCT PERFORMANCE:
Crush (N):
2500
Impact (Nm):
25
Torsion (turns / m):
5
Temp - Operation:
-40°c to +70°c
Temp - Storage:
-40°c to +70°c
Temp - Installation:
-10°c to +70°c
Water Penetration:
<3m @ 24h
Polyethylene Sheath
Diametrically Opposite Ripcords
Gel Filled Loose Tube
Al/PE Moisture Barrier
Individual Inked Fibres
Rigid Glass Central Strength Member
Water Blocking Tape
Fibre Selection
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
OPTICAL COMPONENTS
MFOS is a comprehensive range of premium
products including Single Mode and Multi
Mode Pigtails and Patch cords using ST, SC,
FC and Small Form Factor MT-RJ and LC
Connectors and Adaptors.
All connectorised assembly types are
available as either Multi Mode; OM1, OM2
and OM3 fibre grades and a Single Mode
OS1. All are manufactured to comply with
the international standards ISO 11801 : 2002,
EN50173-1 : 2002 and ANSI/TIA/ETA 568B.
For rack management the Compact Plus
Optical Patch Panel, Cable Management
Plates and Modules offer a flexible cost
effective solution with the ability to cater
for growth and churn.
Available as an empty panel, suitable for all
major connector types the product is able
to manage up to 48 Fibres in 1U using Small
Form Factor connectors.
The sliding shelf design along with other
added features enable quick and easy
reconfiguration, expansion making future
upgrades and expansion both quicker and
easier. Full Blolite support is part of the
flexible future proofing designed into this
product.
Pre-Connectorised Cable Assemblies, Wall
outlets, Consumables, Termination Kits and
Tools complete the range providing an end
to end, in-building and campus
cabling solutions.
3 .33
Optical Systems
Manufactured to comply with: ISO/IEC 11801 : 2002, EN50173 -1 : 2002, ANSI TIA/EIA 568B
All major connector types
Colour coded for identification
Duplex patchcords feature ‘Crossover’
OM1 Grade Fibre
PRODUCT DESCRIPTION:
For use in permanent connections between
transmission equipment and patch panels
or interconnect / cross connect between
panels. Patch cords are pre-constructed with
connectors. These include small form factors
such as LC and MT-RJ as well as SC, FC and
ST. Based on 2.80mm sub units (1.9mm SFF)
these ruggedised cables are sheathed with
LSZH material making them suitable for
internal use.
CABLE PROPERTIES:
Crush (N):
1500
Impact (Nm):
5
Torsion (turns / m):
5
Fire:
IEC 60332-1
Temp - Operation:
-10°c to +70°c
Temp - Storage:
-25°c to +80°c
Temp - Installation:
0°c to +70°c
Sheath Colour:
Orange (Others available on request)
3 .34
Optical Systems
0.5
0.2 0.2
20.0 20.0
0.5
ST SC
Optical Performance (IEC 60874-1 Method 7)
Insertion Loss Max dB
Return Loss Min dB
Insertion Loss Typical dB0.2 0.4 0.2
20.0 20.0 20.0
0.5 0.75 0.5
FC-PC MT-RJ LC
1.00m 2.00m 3.00m 5.00m
Product Part Numbering
FC - FC Duplex
LC - SC Duplex
LC - ST Duplex
LC - LC Duplex
MT-RJ - MT-RJ Duplex
MT-RJ - SC Duplex
MT-RJ - ST Duplex
LC - MT-RJ Duplex
SC - SC Duplex
SC - ST Duplex
ST - ST Duplex
HOPFC062010FC291
HOPLC062010SC293
HOPLC062010ST293
HOPLC062010LC293
HOPMJ062010MJ292
HOPMJ062010SC292
HOPMJ062010ST292
HOPLC062010MJ292
HOPSC062010SC291
HOPSC062010ST291
HOPST062010ST291
HOPFC062020FC291
HOPLC062020SC293
HOPLC062020ST293
HOPLC062020LC293
HOPMJ062020MJ292
HOPMJ062020SC292
HOPMJ062020ST292
HOPLC062020MJ292
HOPSC062020SC291
HOPSC062020ST291
HOPST062020ST291
HOPFC062030FC291
HOPLC062030SC293
HOPLC062030ST293
HOPLC062030LC293
HOPMJ062030MJ292
HOPMJ062030SC292
HOPMJ062030ST292
HOPLC062030MJ292
HOPSC062030SC291
HOPSC062030ST291
HOPST062030ST291
HOPFC062050FC291
HOPLC062050SC293
HOPLC062050ST293
HOPLC062050LC293
HOPMJ062050MJ292
HOPMJ062050SC292
HOPMJ062050ST292
HOPLC062050MJ292
HOPSC062050SC291
HOPSC062050ST291
HOPST062050ST291
Millennium Optical Components - Patch Cords62.5/12.5 Multi Mode Optical Patch Cords
Millennium Optical Components - Patch Cords50/125 Multi Mode Optical Patch Cords
Manufactured to comply with: ISO/IEC 11801 : 2002, EN50173 -1 : 2002, ANSI TIA/EIA 568B
All major connector types
Colour coded for identification
Duplex patch cords feature ‘Crossover’
OM2 Grade Fibre
PRODUCT DESCRIPTION:
For use in permanent connections between
transmission equipment and patch panels
or interconnect / cross connect between
panels. Patch cords are pre-constructed with
connectors. These include small form factors
such as LC and MT-RJ as well as SC, FC and
ST. Based on 2.80mm sub units (1.9mm SFF)
these ruggedised cables are sheathed with
LSZH material making them suitable for
internal use.
CABLE PROPERTIES:
Crush (N):
1500
Impact (Nm):
5
Torsion (turns / m):
5
Fire:
IEC 60332-1
Temp - Operation:
-10°c to +70°c
Temp - Storage:
-25°c to +80°c
Temp - Installation:
0°c to +70°c
Sheath Colour:
Orange (Others available on request)
Optical Systems
3.35
1.00m 2.00m 3.00m 5.00m
Product Part Numbering
FC - FC Duplex
LC - SC Duplex
LC - ST Duplex
LC - LC Duplex
MT-RJ - MT-RJ Duplex
MT-RJ - SC Duplex
MT-RJ - ST Duplex
LC - MT-RJ Duplex
SC - SC Duplex
SC - ST Duplex
ST - ST Duplex
HOPFC050010FC291
HOPLC050010SC293
HOPLC050010ST293
HOPLC050010LC293
HOPMJ050010MJ292
HOPMJ050010SC292
HOPMJ050010ST292
HOPLC050010MJ292
HOPSC050010SC291
HOPSC050010ST291
HOPST050010ST291
HOPFC050020FC291
HOPLC050020SC293
HOPLC050020ST293
HOPLC050020LC293
HOPMJ050020MJ292
HOPMJ050020SC292
HOPMJ050020ST292
HOPLC050020MJ292
HOPSC050020SC291
HOPSC050020ST291
HOPST050020ST291
HOPFC050030FC291
HOPLC050030SC293
HOPLC050030ST293
HOPLC050030LC293
HOPMJ050030MJ292
HOPMJ050030SC292
HOPMJ050030ST292
HOPLC050030MJ292
HOPSC050030SC291
HOPSC050030ST291
HOPST050030ST291
HOPFC050050FC291
HOPLC050050SC293
HOPLC050050ST293
HOPLC050050LC293
HOPMJ050050MJ292
HOPMJ050050SC292
HOPMJ050050ST292
HOPLC050050MJ292
HOPSC050050SC291
HOPSC050050ST291
HOPST050050ST291
Optical Performance (IEC 60874-1 Method 7)
0.5
0.2 0.2 0.2 0.4 0.2
20.0 20.0 20.0 20.0 20.0
0.5 0.5 0.75 0.5
ST SC FC-PC MT-RJ LC
Insertion Loss Max dB
Return Loss Min dB
Insertion Loss Typical dB
Manufactured to comply with: ISO/IEC 11801 : 2002, EN50173 -1 : 2002, ANSI TIA/EIA 568B
All major connector types
Colour coded for identification
Duplex patch cords feature ‘Crossover’
OM3 Grade Fibre
PRODUCT DESCRIPTION:
For use in permanent connections between
transmission equipment and patch panels
or interconnect / cross connect between
panels. Patch cords are pre-constructed with
connectors. These include small form factors
such as LC and MT-RJ as well as SC, FC and
ST. Based on 2.80mm sub units (1.9mm SFF)
these ruggedised cables are sheathed with
LSZH material making them suitable for
internal use.
CABLE PROPERTIES:
Crush (N):
1500
Impact (Nm):
5
Torsion (turns / m):
5
Fire:
IEC 60332-1
Temp - Operation:
-10°c to +70°c
Temp - Storage:
-25°c to +80°c
Temp - Installation:
0°c to +70°c
Sheath Colour:
Orange (Others available on request)
3 .36
Optical Systems
0.5
0.2 0.2 0.2 0.4 0.2
20.0 20.0 20.0 20.0 20.0
0.5 0.5 0.75 0.5
ST SC FC-PC MT-RJ LC
Optical Performance (IEC 60874-1 Method 7)
Insertion Loss Max dB
Return Loss Min dB
Insertion Loss Typical dB
Millennium Optical Components - Patch Cords50/125 OM3 Multi Mode Optical Patch Cords
1.00m 2.00m 3.00m 5.00m
Product Part Numbering
FC - FC Duplex
LC - SC Duplex
LC - ST Duplex
LC - LC Duplex
MT-RJ - MT-RJ Duplex
MT-RJ - SC Duplex
MT-RJ - ST Duplex
LC - MT-RJ Duplex
SC - SC Duplex
SC - ST Duplex
ST - ST Duplex
HOPFCOM3010FC291
HOPLCOM3010SC293
HOPLCOM3010ST293
HOPLCOM3010LC293
HOPMJOM3010MJ292
HOPMJOM3010SC292
HOPMJOM3010ST292
HOPLCOM3010MJ292
HOPSCOM3010SC291
HOPSCOM3010ST291
HOPSTOM3010ST291
HOPFCOM3020FC291
HOPLCOM3020SC293
HOPLCOM3020ST293
HOPLCOM3020LC293
HOPMJOM3020MJ292
HOPMJOM3020SC292
HOPMJOM3020ST292
HOPLCOM3020MJ292
HOPSCOM3020SC291
HOPSCOM3020ST291
HOPSTOM3020ST291
HOPFCOM3030FC291
HOPLCOM3030SC293
HOPLCOM3030ST293
HOPLCOM3030LC293
HOPMJOM3030MJ292
HOPMJOM3030SC292
HOPMJOM3030ST292
HOPLCOM3030MJ292
HOPSCOM3030SC291
HOPSCOM3030ST291
HOPSTOM3030ST291
HOPFCOM3050FC291
HOPLCOM3050SC293
HOPLCOM3050ST293
HOPLCOM3050LC293
HOPMJOM3050MJ292
HOPMJOM3050SC292
HOPMJOM3050ST292
HOPLCOM3050MJ292
HOPSCOM3050SC291
HOPSCOM3050ST291
HOPSTOM3050ST291
Millennium Optical Components - Patch CordsSingle Mode Optical Patch Cords
Manufactured to comply with: ISO/IEC 11801 : 2002, EN50173 -1 : 2002, ANSI TIA/EIA 568B
All major connector types
Colour coded for identification
Duplex patch cords feature ‘Crossover’
OS1 Grade Fibre
PRODUCT DESCRIPTION:
For use in permanent connections between
transmission equipment and patch panels
or interconnect / cross connect between
panels. Patch cords are pre-constructed with
connectors. These include small form factors
such as LC and MT-RJ as well as SC, FC and
ST. Based on 2.80mm sub units (1.9mm SFF)
these ruggedised cables are sheathed with
LSZH material making them suitable for
internal use.
CABLE PROPERTIES:
Crush (N):
1500
Impact (Nm):
5
Torsion (turns / m):
5
Fire:
IEC 60332-1
Temp - Operation:
-10°c to +70°c
Temp - Storage:
-25°c to +80°c
Temp - Installation:
0°c to +70°c
Sheath Colour:
Yellow
3.37
Optical Systems
0.3
0.2 0.2 0.2 0.4 0.1
45.0 45.0 45.0 26.0 45.0
0.3 0.3 0.75 0.3
ST SC FC-PC MT-RJ LC
Optical Performance (IEC 60874-1 Method 7)
Insertion Loss Max dB
Return Loss Min dB
Insertion Loss Typical dB
1.00m 2.00m 3.00m 5.00m
Product Part Numbering
FC - FC Duplex
LC - SC Duplex
LC - ST Duplex
LC - LC Duplex
MT-RJ - MT-RJ Duplex
MT-RJ - SC Duplex
MT-RJ - ST Duplex
LC - MT-RJ Duplex
SC - SC Duplex
SC - ST Duplex
ST - ST Duplex
HOPFC008010FC201
HOPLC008010SC203
HOPLC008010ST203
HOPLC008010LC203
HOPMJ008010MJ202
HOPMJ008010SC202
HOPMJ008010ST202
HOPLC008010MJ202
HOPSC008010SC201
HOPSC008010ST201
HOPST008010ST201
HOPFC008020FC201
HOPLC008020SC203
HOPLC008020ST203
HOPLC008020LC203
HOPMJ008020MJ202
HOPMJ008020SC202
HOPMJ008020ST202
HOPLC008020MJ202
HOPSC008020SC201
HOPSC008020ST201
HOPST008020ST201
HOPFC008030FC201
HOPLC008030SC203
HOPLC008030ST203
HOPLC008030LC203
HOPMJ008030MJ202
HOPMJ008030SC202
HOPMJ008030ST202
HOPLC008030MJ202
HOPSC008030SC201
HOPSC008030ST201
HOPST008030ST201
HOPFC008050FC201
HOPLC008050SC203
HOPLC008050ST203
HOPLC008050LC203
HOPMJ008050MJ202
HOPMJ008050SC202
HOPMJ008050ST202
HOPLC008050MJ202
HOPSC008050SC201
HOPSC008050ST201
HOPST008050ST201
Single Mode and Multi Mode Optical Pigtails Manufactured to comply with: ISO/IEC 11801 : 2002, EN50173 -1 : 2002, ANSI TIA/EIA 568B
Based on Tight Buffered Core 900µm and 600µm
All major connector types
All major fibre types
Colour coded for identification
PRODUCT DESCRIPTION:
For use in permanent connections between
patch panels and incoming cables / single
blown fibres. Pigtails are pre-constructed
with connectors. Connector options include
small form factors such as LC and MT-RJ as
well as SC, FC and ST. Based on 900µm tight
buffered cores (600µm MT-RJ) and suitable
for internal use only inside suitable Fibre
Management Systems.
CABLE PROPERTIES:
Crush (N):
800
Impact (Nm):
0.2
Min Bend (mm):
50
Temp - Operation:
-10°c to +70°c
Temp - Storage:
-25°c to +80°c
Temp - Installation:
0°c to +70°c
3.38
Optical Pigtails
L62 062 H62 L50 050 H50 OM3 Z50 008 D08
Fibre Selection
Product Part Numbering
FC - 1 metre
SC - 1 metre
ST - 1 metre
LC - 1 metre
MT-RJ - 1 metre
HOTFC062001
HOTSC062001
HOTST062001
HOTLS062001
HOTMJ062501
HOTFC050001
HOTSC050001
HOTST050001
HOTLS050001
HOTMJ050501
HOTFCOM3001
HOTSCOM3001
HOTSTOM3001
HOTLSOM3001
HOTMJOM3501
HOTFC008001
HOTSC008001
HOTST008001
HOTLS008001
HOTMJ008501
62.5/125 50/125 50/125 8/125
Product Colour Coding
62.5/125 50/125 50/125 OM3 8/125
Blue
Blue/Orange (MT-RJ)
Green
Green/Brown (MT-RJ)
Grey
Grey/Brown (MT-RJ)
Yellow
Yellow/Green (MT-RJ)
Optical Performance (IEC 60874-1 Method 7)
Insertion Loss Max dB
Insertion Loss Typical dB
0.5
0.2
20.0
ST
45.0
0.2
20.0
0.5
SC
45.0
0.2
20.0
0.5
FC-PC
45.0
0.4
20.0
0.75
MT-RJ
45.0
0.1
20.0
0.3
LC
45.0
Multi Mode Return Loss Min dB
Single Mode Return Loss Min dB
483
220
Millennium Optical Components - Compact Plus Patch PanelsCompact Plus - Unloaded Panels & Panel Options
Sliding tray for easy access complete with quick release fastenings
Suitable for mounting in shallow enclosures due to the adjustable mounting brackets
Minimum depth of 220mm
Rear panel offers a choice of apertures to suit a variety of glanding arrangements
Front panel configuration options:24 way ST, SC, FC-PC48 way MTRJ or Duplex LC
Unloaded panels supplied with cable management and glands (MFCFMKIT001)
The panel base allows for customised fibre management and additional securing for incoming cables
Front panel includes a port identification strip
Suitable for Blolite
PRODUCT DESCRIPTION:
The Compact Plus 1U Fibre Optical panel is
a 19-inch rack mounting optical patch panel.
It is constructed from mild steel with a
painted finish in either black or grey. It offers
a flexible and highly versatile solution for all
applications. The shallow depth allows use
with shallow racks or wall mounted boxes
and the ability to accept all current cable
designs as well as Blolite. The panel has a
number of design features that mean the
product even once installed can be easily
be adapted to changing needs as a
network develops.
Part No.
Product Part Numbering - Black - Unloaded
3.39
Optical Systems
Unloaded Optical Panel for up to 24 ST or FC adaptors - Black
Unloaded Optical Panel for up to 12 SC Duplex adaptors - Black
Unloaded Optical Panel for up to 24 SC Simplex, MT-RJ or LC adaptors - Black
Fibre Management Loops and 24 way splice bridge
Metal Splice Cassettes (x6) including mounting kit
Splice Cassettes (x4) UK Style up to 16 splices each, including mounting kit
Splice Cassettes (x2) EU Style up to 24 splices each, including mounting kit
5mm Clip-in Bloduct Bulkhead Connectors
Blolite Tie Bracket 12w 5mm, including mounting kit
1/2 Blank Tie Bracket
ST/FC Blank Plug - Black
SC Simplex Style Blank Plug - Black
SC Duplex Style Blank Plug - Black
MFCC1SXXX24ST2
MFCC1SXXX24DC2
MFCC1SXXX48SC2
MFCFMKIT001
MFCFMKIT002
MFCFMKIT003
MFCFMKIT004
30-0506-09
MFCBKIT001
MFCBBLK001
BPEST101-100
BPESC101-100
BPESC301-100
Millennium Optical Components - Compact Plus Patch PanelsCompact Plus - Part Loaded Panels
3.40
Optical Systems
4 Adaptor 6 Adaptor 8 Adaptor 12 Adaptor
Product Part Numbering - Black Panels - Part Loaded
ST Single Mode
ST Multi Mode
FC Single Mode
SC Duplex Single Mode
SC Duplex Multi Mode
SC Simplex Single Mode
SC Simplex Multi Mode
MT-RJ
LC Duplex Single Mode
MFCC1SXSM04ST2
MFCC1SXMM04ST2
MFCC1SXSM04FC2
MFCC1SXSM08DC2
MFCC1SXMM08DC2
MFCC1SXSM04SC2
MFCC1SXMM04SC2
MFCC1SXMM08MJ2
MFCC1SXSM08LC2
MFCC1SXSM06ST2
MFCC1SXMM06ST2
MFCC1SXSM06FC2
MFCC1SXSM12DC2
MFCC1SXMM12DC2
MFCC1SXSM06SC2
MFCC1SXMM06SC2
MFCC1SXMM12MJ2
MFCC1SXSM12LC2
MFCC1SXSM08ST2
MFCC1SXMM08ST2
MFCC1SXSM08FC2
MFCC1SXSM16DC2
MFCC1SXMM16DC2
MFCC1SXSM08SC2
MFCC1SXMM08SC2
MFCC1SXMM16MJ2
MFCC1SXSM16LC2
MFCC1SXSM12ST2
MFCC1SXMM12ST2
MFCC1SXSM12FC2
MFCC1SXSM24DC2
MFCC1SXMM24DC2
MFCC1SXSM12SC2
MFCC1SXMM12SC2
MFCC1SXMM24MJ2
MFCC1SXSM24LC2
MFCC1SXSM16ST2
MFCC1SXMM16ST2
MFCC1SXSM16FC2
-
-
MFCC1SXSM16SC2
MFCC1SXMM16SC2
MFCC1SXMM32MJ2
MFCC1SXSM32LC2
MFCC1SXSM24ST2
MFCC1SXMM24ST2
MFCC1SXSM24FC2
-
-
MFCC1SXSM24SC2
MFCC1SXMM24SC2
MFCC1SXMM48MJ2
MFCC1SXSM48LC2
16 Adaptor 24 Adaptor
Compact Plus Panels are pre loaded with Fibre Optic adaptors
Front Panel for up to 24way FC, ST, SC 12 way DC, 48way LC, MT-RJ
Minimum depth 220mm
Front Panel includes a port identification strip
Suitable for Blolite
PRODUCT DESCRIPTION:
The Compact Plus 1U Fibre Optical panel is
a 19-inch rack mounting optical patch panel.
It is constructed from mild steel with a
painted finish in either black or grey. It offers
a flexible and highly versatile solution for all
applications. The shallow depth allows use
with shallow racks or wall mounted boxes
and the ability to accept all current cable
designs as well as Blolite. The panel has a
number of design features that mean the
product even once installed can be easily be
adapted to changing needs as a
network develops.
483
220
MillenniuM Optical Components - ConnectorsSC Optical Connectors
Connector Adaptor
Product Part Numbering
3.41
Optical Systems
SC Simplex Connector:
SC multimode and single mode
connector kits comprise of a one
piece SC body with precision
ceramic ferrule, crimp, sleeve,
colour coded outer shroud, 2 x
colour coded 3mm strain relief
boots and a 0.9mm boot.
Compliant with IEC60874-14
Typical Insertion Loss:
MM - 0.2dB, SM - 0.15dB
Minimum Return Loss:
SM 45dB
SC Duplex Connector:
SC Duplex connector kits
comprise of 2 simplex connectors
mounted in a two piece polymer
clip and 2 x colour coded 3mm
strain relief boots.
Compliant with IEC 60874-14
Typical Insertion Loss:
MM - 0.2dB, SM - 0.15dB
Minimum Return Loss:
SM 45dB
SC Simplex Adaptor:
SC Adaptors comprise of a
polymer outer body and inner
assembly fitted with a precision
alignment sleeve.
Multimode with metal sleeve.
Single mode with Ceramic Sleeve.
Compliant with IEC 60875-14
Max. Insertion Loss:
MM - 0.3dB, SM - 0.1dB
SC Duplex Adaptor:
SC Duplex adaptors comprise of a
polymer outer body and an inner
assembly fitted with a precision
alignment sleeve.
Multimode with metal sleeve.
Single mode with Ceramic Sleeve.
Compliant with IEC 60875-14
Max. Insertion Loss:
MM - 0.3dB, SM - 0.1dB
BHCSCMM001
BHCSCSM001
BHCDCMM001
BHCDCSM001
SC - MultiMode (Beige)
SC - Single Mode (Blue)
SC Duplex - Multi Mode (Beige)
SC Duplex - Single Mode (Blue)
SC Duplex Clip - Multi Mode (Beige)
SC Duplex Clip - Single Mode (Blue)
FOCSCEPMM001
FOCSCEPSM001
FOCDCEPMM001
FOCDCEPSM001
FOCSCKLBE
FOCSCKLBU
MillenniuM Optical Components - ConnectorsST, FC Optical Connectors
FOCSTEPMM001
FOCSTEPSM001
FOCFCEPSM001
BHCSTMM001
BHCSTSM001
BHCFCSM001
ST - Multi Mode
ST Single Mode
FC-PC Single Mode
Connector Adaptor
Product Part Numbering
3.42
Optical Systems
ST Adaptor:
ST adaptors comprise of a nickel
plated zinc die cast body with a
precision alignment sleeve. They
are both standard and double ‘D’
hole compatible.
Multimode with metal sleeve.
Single mode with ceramic sleeve.
Compliant with IEC 60875-10
Max. Insertion Loss:
MM - 0.3dB, SM - 0.1dB
FC Adaptor:
FC adaptors comprise of a nickel
plated brass body that is fitted
with a precision alignment sleeve.
They are standard single and
double 'D' hole compatible.
Compliant with IEC 60875-7
Max. Insertion Loss:
SM - 0.1dB
ST Connector:
ST connector kits comprise of a
nickel plated zinc coupling body
with a precision ceramic ferrule,
crimp sleeve, 2 x colour coded
3mm strain reliefs and a
0.9mm boot.
Compliant with IEC 60874-10
Strain Relief Colour Code:
MM - Red, Black
SM - Yellow, Black
Typical Insertion Loss:
MM - 0.2dB, SM - 0.15dB
Minimum Return Loss:
SM 45dB
FC-PC Connector:
FC-PC single mode connector kits
comprise of a nickel plated brass
body with a precision ceramic
ferrule, stepped crimp sleeve,
2 x colour coded strain relief boots
and a 0.9mm boot.
Compliant with IEC 60874-7
Strain Relief Colour Code:
SM - Yellow, Black
Typical Insertion Loss:
SM - 0.15dB
Minimum Return Loss:
SM 45dB
MillenniuM Optical Components - ConnectorsSmall Form Factor Connectors LC/MT RJ
FOCLCEPMM001
FOCLCEPSM001
FOCLSEPMM001
FOCLSEPSM001
FOCMJEPMM001
FOCMJEPSM001
FOCMJEPMM002
FOCMJEPSM002
FOCMJFI050001
FOCMJFI062001
FOCMJFI008001
BHCLCMM001
BHCLCSM001
-
-
BHCMJXX001
BHCMJXX001
BHCMJXX001
BHCMJXX001
BHCMJXX001
BHCMJXX001
BHCMJXX001
LC Multi Mode (Duplex) (Beige)
LC Single Mode (Duplex) (Blue)
LC Multi Mode (Simplex) (Beige)
LC Single Mode (Simplex) (Blue)
MT-RJ Multi Mode (Male)
MT-RJ Single Mode (Male)
MT-RJ Multi Mode (Female)
MT-RJ Single Mode (Female)
MT-RJ Multi Mode - Field Install
MT-RJ Multi Mode - Field Install
MT-RJ Single Mode - Field Install
Connector Adaptor
Product Part Numbering
3.43
Optical Systems
MT-RJ Duplex Connector:
MT-RJ connectors are available
in male (with guide pins) or
female (without) and are supplied
with oval crimp sleeve, outer
shroud, strain relief boot and
a short buffer boot.
Typical Insertion Loss:
MM - <0.3dB, SM - <0.7dB
Minimum Return Loss:
MM 22dB, SM 26dB
MT-RJ Duplex Adaptor:
MT-RJ adaptors have a polymer
outer body which has the outer
dimensions of a simplex
SC sized adaptor.
LC Connector:
LC multimode and single mode
connector kits comprise of a
precision ferrule, crimp sleeve,
colour coded outer shroud, 2 x
colour coded 2.0mm strain reliefs
and a 0.9mm boot.
Typical Insertion Loss:
MM - <0.2dB, SM - <0.15dB
Minimum Return Loss:
MM 20dB, SM 45dB
Available as either simplex
or duplex variants.
LC Duplex Adaptor:
LC adaptors comprise of a
polymer body with a precision
alignment sleeves. They have the
outer dimensions of a simplex SC
sized adaptor.
PRODUCT DESCRIPTION:
The range of Brand-Rex SFF (Small Form
Factor) connectivity solutions are reliable
and robust, quality products. SFF connectors
are duplex fibre connectors which have
a footprint similar to RJ-45's, offering the
system integrator / installer an improved
patching density, saving valuable rack space.
The products can be used at the panel or in
the work area supporting both backbone
fibre and fibre to the desk solutions.
Brand-Rex offers a choice of leading, de-
facto, SFF connectors, the MT-RJ and the
LC. The MT-RJ is also available as
field installable.
Millennium Optical Components - Wall and Floor Outlets Available for most connector types; SC Simplex, SC Duplex, ST, LC, MT-RJ
Allows up to 2 Fibre Terminations per Module (Small Form Factor all 4 Fibres per Module)
Angled Fibre Optic Module supplied with Adaptors
Compatible Standard Modular Wall Mounted Faceplates
PRODUCT DESCRIPTION:
A range of wall and floor mounted
angled housings for use with fibre optic
terminations, designed for mounting on
a standard modular range faceplate or
adaptor collar.
3 .44
Optical Systems
Multi-Mode
Product Part Numbering
50 x 50 mm Angled Module with 2 x ST Adaptors
50 x 50 mm Angled Module with an SC Duplex Adaptor
50 x 50 mm Angled Module with 2 x LC Adaptors
50 x 50 mm Angled Module with 2 x MT-RJ Adaptors
50 x 50 mm Angled Module with 2 x FC/PC Adaptors
86 x 147 mm Double Gang Modular Faceplate
44 mm deep Double Gang UK Backbox
60 x 60 mm Adaptor Collar
MFCSTMM001
MFCDCMM001
MFCLCMM001
MFCMJXM001
-
147
44
86
MFCSTSM001
MFCDCSM001
MFCLCSM001
MFCMJXM001
MFCFCSM001
Single-Mode
MMCWDOUNI031
MMCDGBB44002
TAC2W
MillenniuM Optical Components - Consumables and ToolsConsumables and Tools
HELTKITEP001
HELTKITEP002
HELACCEP001
HELACCEP002
HELTKITEP003
MFOS Starter Kit
MFOS Tool Wallet
500 Termination Consumable Kit
50 Termination Consumable Kit
MFOS Conversion Kit
Part Number
Product Part Numbering
Optical Systems
MFOS Starter Kit:
The MFOS Starter Kit contains:
Consumable kits for 1000
terminations, Sheath stripper
small - (up to 3mm), Sheath
stripper medium (3 - 5.5mm),
Sheath stripper large (6.5 - 14mm),
No Nik stripper for 900 µm buffer,
Clauss stripper for 250 µm fibre
coating, Crimp tool for BR ST/SC/
FC connectors, Kevlar Scissors,
Scribe, Polishing Puck for ST/SC/
FC connectors, x3 Rubber pads for
hand polishing, 6 position curing
oven with power supply, Water
bottle for polishing liquid, Sharps
disposal bin, Safety Glasses, Mains
adaptor for UK to Euro, ST/SC/FC
Inspection MicroScope (x200).
MFOS Tool Wallet:
The MFOS Tool Wallet contains:
Sheath stripper small - (up to
3mm), Sheath stripper medium
(3 - 5.5mm), Sheath stripper large
(6.5 - 14mm), No Nik stripper for
900 µm buffer, Clauss stripper
for 250 µm fibrecoating, Crimp
tool for Brand-Rex ST/SC/FC
connectors, Kevlar Scissors, Scribe,
Polishing Puck for ST/SC/FC
connectors.
MFOS 500 Termination
Consumable Kit:
The MFOS 500 Terminations
Consumable Kit contains:
Polishing film, epoxy, cleaning
solvent and tissues sufficient for
500 on-site terminations.
MFOS 50 Termination
Consumable Kit:
The MFOS 50 Terminations
Consumable Kit contains:
Polishing film, epoxy, cleaning
solvent and tissues sufficient for
50 on-site terminations.
MFOS Conversion Kit:
The MFOS Conversion Kit
contains: Connector crimp tool
and polishing puck for Brand-Rex
ST/SC/FC connectors.
PRODUCT DESCRIPTION:
Brand-Rex offers a range of termination
kits for epoxy-polish type connectors. The
Starter Kit is a comprehensive tool kit, which
includes all the tools necessary to achieve
quality terminations in the workshop, lab or
on-site. The MFOS Tool Wallet contains all
the hand tools necessary for preparing and
terminating Brand-Rex ST/SC/FC connectors,
and the Conversion Kit consists of the
correct crimp tool and polishing puck for
Brand-Rex SC/ST/FC connectors.
Brand-Rex supplies field installation tool kits
for the SFF connector range. A polishing
puck for LC connectors is available for
epoxy polish terminations. Various field
termination kits are also available for the
field installable product range.
3 .45
UNLOCK YOURNETWORK’S FULL
POTENTIAL
Therearemanyfactorstoconsiderwhendecidingwhototrustwithyourinfrastructure
system.Withoutmakingthecorrectchoices,thetruepotentialofyournetworkwillnever
beunlocked.AtBrand-Rex,weofferwarrantedandindependentlycertifiednetwork
solutionsthatexceedtherelevantindustrystandards,fortheultimateinpeaceofmind.
That’swhywearetheUK’smarketleadingproviderofstructuredcablingsystems.
Brand-Rex–bettermadebydesign.
viewfieldindustrialestate·glenrothes·fife·KY62RS·unitedkingdom·t:+44(0)1592772124·w:www.brand-rex.com
Customer requirements in the ever-advancing
communications market continues to grow, stretching
scarce bandwidth resources and truly testing the
performance of today's networks.
In choosing cabling system solutions, whether for small,
medium or large multi site locations, server farms or
co location datacentres, network planners have some
serious issues to consider. Among these is the decision
as to which type and mix of fibre to install to allow for
network expansion and upgrade has been a dilemma
for many years.
In the past, industry practice has been to install 'dark
fibre' to meet future demands, however, this strategy is
by no means risk-free as unterminated, untested fibres
may not be fit for purpose when the time comes to light
the fibres in the future.
Fortunately there is a simple and cost effective solution -
MillenniuM Air Blown Fibre Systems from Brand-Rex offer
solutions Internal and External applications with their
market leading systems Blolite and MicroBlo. The use of
Air Blown Fibre Systems gives complete freedom from
risk by pre-installing a ducting route and then blowing in
the fibre element (and paying for it) only when required.
Air Blown Fibre Systems
4.1
RELIABLEPERFORMANCE
Brand-Rexproductsaredesigned,engineeredandtestedforexcellence.Wedon’tmake‘golden’samplesinordertosecurethirdpartyapprovals,becausedeliveringqualityproductsasstandardisaconstantandvitalpartofourcommitmenttocustomersworldwide.That’swhywearetheUK’smarketleadingproviderofstructuredcablingsystems.
Brand-Rex–bettermadebydesign.
viewfieldindustrialestate·glenrothes·fife·KY62RS·unitedkingdom·t:+44(0)1592772124·w:www.brand-rex.com
100
50
25
75
1005025 75
BLOLITE:
The Blolite system was the one of the first
Air Blown Fibre systems, it is also regarded
as the 'industry standard' Air Blown Fibre
System. The Blolite system is very versatile
with backbone and / or fibre to the desk
links and can even allow for long distance
link of up to 1km. Blolite is easily installed, by
using compressed air, there is no disruption
to the workplace, Blolite fibres are simply
terminated and are compatible with all
standard optical connectors.
Blolite is also extremely reliable, with a zero
failure rate since the first installations in
1988 - truly an 'insurance policy' for high
speed networks. It is no surprise that
major users such as Manchester Airport,
IBM, Ericsson, ABN Amro, the British MoD,
Aerospatiale, Pfizer and even the US Navy
have taken advantage of the system.
4.2
Air Blown Fibre Systems
MillenniuM Air Blown Fibre - BloliteBlolite Internal MultiDucts
Available with 5mm or 8mm MicroDucts
Non Metallic Design
MicroDuct Numbered for Identification
PRODUCT DESCRIPTION:
To facilitate the installation of Blolite
single blown fibres a range of multi-way
MicroDucts into which Blolite fibres, can be
blown are available. The internal range of
these MultiDucts are constructed with the
standard Blolite LSZH MicroDuct surrounded
with a layer of polyester tape and a LSZH
outer sheath making them suitable for
internal applications.
PRODUCT PERFORMANCE:
Fire:
IEC 60332-1
Temp - Operation:
-25°c to +70°c
Temp - Storage:
-40°c to +80°c
Temp - Installation
-10°c to +70°c
32
73
129
203
--
--
32
135
265
380
--
5.0
7.5 x 13.0
15.2
18.6
24.0
29.6
8.0
10.5 x 19.0
23.0
27.6
36.0
50
300
500
700
1150
1650
120
600
1000
1500
--
25
40
128
180
350
410
40
80
180
270
--
Single 5mm MicroDuct
2w 5mm (LSZH) - O
4w 5mm (LSZH) - I
7w 5mm (LSZH) -I
12w 5mm (LSZH) - I
19w 5mm (LSZH -I
Single 8mm MicroDuct
2w 8mm (LSZH) - I
4w 8mm (LSZH) - I
7w 8mm (LSZH) - I
12w 8mm (LSZH) -I
Diameter
mm
Weight
kg / km
Max TensileLoad
N
MinStatic Bend
mm
Product Data
LSZH Outer Sheath
Polyester Tape
MicroDuct
4 .3
Air Blown Fibre Systems
20-0101-00
n/a
20-0201-06
20-0401-06
20-0701-06
20-1201-06
20-1901-06
20-0104-00
n/a
20-0204-06
20-0404-06
20-0704-06
20-1204-06
n/a
Single MicroDuct
1 Way MultiDuct
2 Way MultiDuct
4 Way MultiDuct
7 Way MultiDuct
12 Way MultiDuct
19 Way MultiDuct
5.00mm 8.00mm
Product Part Numbering
MillenniuM Air Blown Fibre - BloliteBlolite External MultiDucts
Available with 5mm or 8mm MicroDucts
Aluminium Moisture Barrier
MicroDuct Numbered for Identification
PRODUCT DESCRIPTION:
To facilitate the installation of Blolite
single blown fibres a range of multi-way
MicroDucts into which Blolite fibres can be
blown are available. The external range of
these MultiDucts are constructed with the
standard Blolite LSZH MicroDuct surrounded
with a layer of coated aluminium tape and
a Polyethylene outer sheath making them
suitable for external applications.
PRODUCT PERFORMANCE:
Temp - Operation:
-25°c to +70°c
Temp - Storage:
-40°c to +80°c
Temp - Installation
-10°c to +70°c
21-0101-02
21-0201-02
21-0401-02
21-0701-02
21-1201-02
21-1901-02
21-0104-02
21-0204-02
21-0404-02
21-0704-02
21-1204-02
n/a
1 Way MultiDuct
2 Way MultiDuct
4 Way MultiDuct
7 Way MultiDuct
12 Way MultiDuct
19 Way MultiDuct
5.00mm 8.00mm
Product Part Numbering
32
73
129
203
--
--
32
135
265
380
--
7.5
7.5 x 13.0
15.2
18.6
24.0
29.6
10.5
10.5 x 19.0
23.0
27.6
36.0
380
630
900
1250
1800
2600
--
--
--
--
--
40
60
180
250
310
370
80
95
280
380
--
1w 5mm (LSZH) - O
2w 5mm (LSZH) - O
4w 5mm (LSZH) - O
7w 5mm (LSZH) - O
12w 5mm (LSZH) - O
19w 5mm (LSZH - O
1w 8mm (LSZH) - O
2w 8mm (LSZH) - O
4w 8mm (LSZH) - O
7w 8mm (LSZH) - O
12w 8mm (LSZH) - O
Diameter
mm
Weight
kg / km
Max TensileLoad
N
MinStatic Bend
mm
Product Data
4.4
Air Blown Fibre Systems
PE Outer Sheath
Coated Aluminium Tape
MicroDuct
MillenniuM Air Blown Fibre - BloliteSingle Blown Fibre Elements
Unique ‘Blowable’ coating.
12 Standard Colours.
Installation up to 1000m.
PRODUCT DESCRIPTION:
The Blolite system offers a complete range
of high quality single mode and multimode
optical fibres, with a blowable coating and
having a finished size of 500 µm.
The Blolite fibre is strippable with standard
tools and is compatible with standard
connector types.
Fibre is available in twelve standard colours
and is supplied on plastic spools in 1km,
2km, 3km or 4km lengths for installation
into Blolite 5mm and 8mm MicroDuct by
trained and licensed Blolite installers using
the IM2000 blow head.
Outer Buffer Layer
First Buffer Layer
Primary Coating
125µm Cladding
Fibre Core
4 .5
Air Blown Fibre Systems
500
500
500
500
400
1000
1000
1000
1000
50012 Fibre
8 Fibre
6 Fibre
4 Fibre
2 Fibre
5mmMicroDuct
m
8mmMicroDuct
m
Installation Distances
PLANNED INSTALLATION DISTANCES:
When using approved equipment and
products the following distances should be
used for planning purposes. These assume a
non tortuous route, which is a route with all
bends over 400mm in diameter and no more
than 20 occurrences of 90 degrees in the
length of the route.
10-0101-03
10-0101-05
10-0101-06
10-0101-07
10-0101-08
10-0101-09
10-0101-10
10-0101-11
10-0101-12
10-0101-13
10-0101-14
10-0101-15
10-0005-03
10-0005-05
10-0005-06
10-0005-07
10-0005-08
10-0005-09
10-0005-10
10-0005-11
10-0005-12
10-0005-13
10-0005-14
10-0005-15
10-0003-03
10-0003-05
10-0003-06
10-0003-07
10-0003-08
10-0003-09
10-0003-10
10-0003-11
10-0003-12
10-0003-13
10-0003-14
10-0003-15
10-0200-03
10-0200-05
10-0200-06
10-0200-07
10-0200-08
10-0200-09
10-0200-10
10-0200-11
10-0200-12
10-0200-13
10-0200-14
10-0200-15
White
Black
Blue
Orange
Green
Red
Grey
Yellow
Brown
Violet
Pink
Turquoise
62.5/125 50/125 OM3 8/125
Product Part Numbering
Blolite Pneumatic ConnectorsPneumatic Tube Connectors
PRODUCT DESCRIPTION:
Within Blolite a range of plastic bodied
pneumatic tube connectors are used for
tube routing. The connectors have a variety
of forms and are all rated for the maximum
working pressure used on Blolite of 10 Bar.
The connectors are installed with a simple
push-pull technique and can be re-used
several times.
30-0501-00
30-0502-00
30-0504-00
30-0505-09
30-0506-09
30-0507-05
30-0508-00
30-5801-00
-
30-5810-05
30-0801-00
30-0802-00
30-0804-00
30-0805-09
-
30-0807-05
30-0808-00
-
30-0809-05
-
Straight - Push/Pull
Straight - Screw Retention
End Stop
Connector End Plug
Bulkhead Mounted Connector
Dust Cap
Gas Blocking ‘T’ Piece
8mm to 5mm Reducer
Termination Fibre Diverter
8mm to 5mm Stem Converter
5mm MicroductConnector Type 8mm Microduct
Product Part Numbering
4.6
Air Blown Fibre Systems
Straight
Connector:
For connecting
2 equal size
microducts.
End Plug:
For blocking
a straight
connector when
a later connection
is required.
Gas Blocking ‘T’:
For use with resin
to provide a gas
blocking seal
where required.
8mm - 5mm
Reducer:
To reduce from
8mm - 5mm
MicroDuct at
termination point.
Termination
Splitter / Stem
Converter:
For use at the end
of a duct route
to divert fibres
into different
termination
points.
Bulkhead
Connector:
For attaching a
microduct to
a panel or wall
box.
Dust Cap:
For preventing
the ingress of
dust during
installation.
Straight Screw
Connector:
For connecting
2 equal size
microducts and
eliminating
movement at
joint.
End Stop:
For blocking
of the end of a
redundant tube or
temporary sealing.
MillenniuM Air Blown FibreTools
54-0100-00
54-0201-00
54-0202-00
54-0300-00
50-0506-00
Radial Tube Cutter
Duct Stripping Tool 4.5mm - 29.00mm
Duct Stripping Tool 19.00mm - 40.00mm
Duct Stripping Tool Spare Blades
Duct Testing Kit
Part Number
Product Part Numbering
4.7
Air Blown Fibre Systems
Radial Tube
Cutter:
Duct Stripping
Tool
4.5mm -
29.00mm:
Duct Stripping
Tool
19.0mm -
40.00mm:
Duct Testing Kit:
viewfieldindustrialestate·glenrothes·fife·KY62RS·unitedkingdom·t:+44(0)1592772124·w:www.brand-rex.com
RELIABILITY WHEN YOU
NEED IT MOST
StructuredcablingsystemsmanufacturedbyBrand-Rexaredesignedtooffer
exceptionalperformance,underpinnedbythemostcomprehensive25-yearwarranty
onthemarket.Inanareawhereaestheticsarenoguaranteeofquality,Brand-Rexoffers
highqualityandreliablesolutionsforcopperandopticalcabling.
Brand-Rex–performancethroughdesignexcellence.
Product Part Number Index
10-0003-03 4.510-0003-05 4.510-0003-06 4.510-0003-07 4.510-0003-08 4.510-0003-09 4.510-0003-10 4.510-0003-11 4.510-0003-12 4.510-0003-13 4.510-0003-14 4.510-0003-15 4.510-0005-03 4.510-0005-05 4.510-0005-06 4.510-0005-07 4.510-0005-08 4.510-0005-09 4.510-0005-10 4.510-0005-11 4.510-0005-12 4.510-0005-13 4.510-0005-14 4.510-0005-15 4.510-0101-03 4.510-0101-05 4.510-0101-06 4.510-0101-07 4.510-0101-08 4.510-0101-09 4.510-0101-10 4.510-0101-11 4.510-0101-12 4.510-0101-13 4.510-0101-14 4.510-0101-15 4.510-0200-03 4.510-0200-05 4.510-0200-06 4.510-0200-07 4.510-0200-08 4.510-0200-09 4.510-0200-10 4.510-0200-11 4.510-0200-12 4.510-0200-13 4.510-0200-14 4.510-0200-15 4.520-0101-00 4.320-0104-00 4.320-0201-06 4.320-0204-06 4.320-0401-06 4.320-0404-06 4.320-0701-06 4.320-0704-06 4.320-1201-06 4.320-1204-06 4.320-1901-06 4.321-0101-02 4.421-0104-02 4.421-0201-02 4.421-0204-02 4.421-0401-02 4.421-0404-02 4.421-0701-02 4.421-0704-02 4.421-1201-02 4.421-1204-02 4.421-1901-02 4.430-0501-00 4.630-0502-00 4.630-0504-00 4.630-0505-09 4.630-0506-09 3.3930-0506-09 4.630-0507-05 4.6
30-0508-00 4.630-0801-00 4.630-0802-00 4.630-0804-00 4.630-0805-09 4.630-0807-05 4.630-0808-00 4.630-0809-05 4.630-5801-00 4.630-5810-05 4.654-0100-00 4.754-0201-00 4.754-0202-00 4.754-0300-00 4.754-0506-00 4.7BHCDCMM001 3.41BHCDCSM001 3.41BHCFCSM001 3.42BHCLCMM001 3.43BHCLCSM001 3.43BHCMJXX001 3.43BHCSCMM001 3.41BHCSCSM001 3.41BHCSTMM001 3.42BHCSTSM001 3.42BPESC101-100 3.39BPESC301-100 3.39BPEST101-100 3.39FOCDCEPMM001 3.41FOCDCEPSM001 3.41FOCFCEPSM001 3.42FOCLCEPMM001 3.43FOCLCEPSM001 3.43FOCLSEPMM001 3.43FOCLSEPSM001 3.43FOCMJEPMM001 3.43FOCMJEPMM002 3.43FOCMJEPSM001 3.43FOCMJEPSM002 3.43FOCMJFI008001 3.43FOCMJFI050001 3.43FOCMJFI062001 3.43FOCSCEPMM001 3.41FOCSCEPSM001 3.41FOCSCKLBE 3.41FOCSCKLBU 3.41FOCSTEPMM001 3.42FOCSTEPSM001 3.42HELACCEP001 3.45HELACCEP002 3.45HELTKITEP001 3.45HELTKITEP002 3.45HELTKITEP003 3.45HF008C12LU PDS 3.8HF008C16LU PDS 3.8HF008C24LU PDS 3.8HF008C2LU PDS 3.8HF008C4LU PDS 3.8HF008C6LU PDS 3.8HF008C8LU PDS 3.8HF008S108W(E)LU MRU03 3.23HF008S108W(E)NM MRE03 3.23HF008S108WLSTALU MSU203 3.29HF008S108WLU MDU03 3.20HF008S108WMB MAE03 3.32HF008S108WNM MDE03 3.20HF008S108WNMSTANM MSE203 3.29HF008S108WSTALU MSU03 3.26HF008S108WSTANM MSE03 3.26HF008S120W(E)LU MRU03 3.23HF008S120W(E)NM MRE03 3.23HF008S120WLSTALU MSU203 3.29HF008S120WLU MDU03 3.20HF008S120WMB MAE03 3.32HF008S120WNM MDE03 3.20HF008S120WNMSTANM MSE203 3.29HF008S120WSTALU MSU03 3.26
HF008S120WSTANM MSE03 3.26HF008S12W(E)LU MRU01 3.21HF008S12W(E)LU MRU02 3.22HF008S12W(E)NM MRE01 3.21HF008S12W(E)NM MRE02 3.22HF008S12WLSTALU MSU201 3.27HF008S12WLSTALU MSU202 3.28HF008S12WLU MDU01 3.18HF008S12WLU MDU02 3.19HF008S12WMB MAE01 3.30HF008S12WMB MAE02 3.31HF008S12WNM MDE01 3.18HF008S12WNM MDE02 3.19HF008S12WNMSTANM MSE201 3.27HF008S12WNMSTANM MSE202 3.28HF008S12WSTALU MSU01 3.24HF008S12WSTALU MSU02 3.25HF008S12WSTANM MSE01 3.24HF008S12WSTANM MSE02 3.25HF008S132W(E)LU MRU03 3.23HF008S132W(E)NM MRE03 3.23HF008S132WLSTALU MSU203 3.29HF008S132WLU MDU03 3.20HF008S132WMB MAE03 3.32HF008S132WNM MDE03 3.20HF008S132WNMSTANM MSE203 3.29HF008S132WSTALU MSU03 3.26HF008S132WSTANM MSE03 3.26HF008S144W(E)LU MRU03 3.23HF008S144W(E)NM MRE03 3.23HF008S144WLSTALU MSU203 3.29HF008S144WLU MDU03 3.20HF008S144WMB MAE03 3.32HF008S144WNM MDE03 3.20HF008S144WNMSTANM MSE203 3.29HF008S144WSTALU MSU03 3.26HF008S144WSTANM MSE03 3.26HF008S16W(E)LU MRU01 3.21HF008S16W(E)NM MRE01 3.21HF008S16WLSTALU MSU201 3.27HF008S16WLU MDU01 3.18HF008S16WMB MAE01 3.30HF008S16WNM MDE01 3.18HF008S16WNMSTANM MSE201 3.27HF008S16WSTALU MSU01 3.24HF008S16WSTANM MSE01 3.24HF008S20W(E)LU MRU01 3.21HF008S20W(E)NM MRE01 3.21HF008S20WLSTALU MSU201 3.27HF008S20WLU MDU01 3.18HF008S20WMB MAE01 3.30HF008S20WNM MDE01 3.18HF008S20WNMSTANM MSE201 3.27HF008S20WSTALU MSU01 3.24HF008S20WSTANM MSE01 3.24HF008S24W(E)LU MRU01 3.21HF008S24W(E)LU MRU02 3.22HF008S24W(E)NM MRE01 3.21HF008S24W(E)NM MRE02 3.22HF008S24WLSTALU MSU201 3.27HF008S24WLSTALU MSU202 3.28HF008S24WLU MDU01 3.18HF008S24WLU MDU02 3.19HF008S24WMB MAE01 3.30HF008S24WMB MAE02 3.31HF008S24WNM MDE01 3.18HF008S24WNM MDE02 3.19HF008S24WNMSTANM MSE201 3.27HF008S24WNMSTANM MSE202 3.28HF008S24WSTALU MSU01 3.24HF008S24WSTALU MSU02 3.25HF008S24WSTANM MSE01 3.24HF008S24WSTANM MSE02 3.25HF008S36W(E)LU MRU02 3.22HF008S36W(E)NM MRE02 3.22HF008S36WLSTALU MSU202 3.28HF008S36WLU MDU02 3.19
Productpartnumber Page Productpartnumber Page Productpartnumber Page
Product Part Number Index
HF008S36WMB MAE02 3.31HF008S36WNM MDE02 3.19HF008S36WNMSTANM MSE202 3.28HF008S36WSTALU MSU02 3.25HF008S36WSTANM MSE02 3.25HF008S48W(E)LU MRU02 3.22HF008S48W(E)NM MRE02 3.22HF008S48WLSTALU MSU202 3.28HF008S48WLU MDU02 3.19HF008S48WMB MAE02 3.31HF008S48WNM MDE02 3.19HF008S48WNMSTANM MSE202 3.28HF008S48WSTALU MSU02 3.25HF008S48WSTANM MSE02 3.25HF008S4W(E)LU MRU01 3.21HF008S4W(E)NM MRE01 3.21HF008S4WLSTALU MSU201 3.27HF008S4WLU MDU01 3.18HF008S4WMB MAE01 3.30HF008S4WNM MDE01 3.18HF008S4WNMSTANM MSE201 3.27HF008S4WSTALU MSU01 3.24HF008S4WSTANM MSE01 3.24HF008S60W(E)LU MRU02 3.22HF008S60W(E)NM MRE02 3.22HF008S60WLSTALU MSU202 3.28HF008S60WLU MDU02 3.19HF008S60WMB MAE02 3.31HF008S60WNM MDE02 3.19HF008S60WNMSTANM MSE202 3.28HF008S60WSTALU MSU02 3.25HF008S60WSTANM MSE02 3.25HF008S72W(E)LU MRU02 3.22HF008S72W(E)NM MRE02 3.22HF008S72WLSTALU MSU202 3.28HF008S72WLU MDU02 3.19HF008S72WMB MAE02 3.31HF008S72WNM MDE02 3.19HF008S72WNMSTANM MSE202 3.28HF008S72WSTALU MSU02 3.25HF008S72WSTANM MSE02 3.25HF008S8W(E)LU MRU01 3.21HF008S8W(E)NM MRE01 3.21HF008S8WLSTALU MSU201 3.27HF008S8WLU MDU01 3.18HF008S8WMB MAE01 3.30HF008S8WNM MDE01 3.18HF008S8WNMSTANM MSE201 3.27HF008S8WSTALU MSU01 3.24HF008S8WSTANM MSE01 3.24HF008S96W(E)LU MRU03 3.23HF008S96W(E)NM MRE03 3.23HF008S96WLSTALU MSU203 3.29HF008S96WLU MDU03 3.20HF008S96WMB MAE03 3.32HF008S96WNM MDE03 3.20HF008S96WNMSTANM MSE203 3.29HF008S96WSTALU MSU03 3.26HF008S96WSTANM MSE03 3.26HF008T12LU BKO 3.12HF008T16LU BKO 3.12HF008T1L SFC 3.10HF008T24LU BKO 3.12HF008T2L DUP 3.11HF008T2ZL ZIP 3.10HF008T4LU BKO 3.12HF008T6LU BKO 3.12HF008T8LU BKO 3.12HF008UNI12(E)LU URU 3.15HF008UNI12(E)NM URE 3.15HF008UNI12LSTALU USU2 3.17HF008UNI12LU UDU 3.14HF008UNI12NM UDE 3.14HF008UNI12NMSTANM USE2 3.17HF008UNI12STALU USU 3.16HF008UNI12STANM USE 3.16HF008UNI16(E)LU URU 3.15
HF008UNI16(E)NM URE 3.15HF008UNI16LSTALU USU2 3.17HF008UNI16LU UDU 3.14HF008UNI16NM UDE 3.14HF008UNI16NMSTANM USE2 3.17HF008UNI16STALU USU 3.16HF008UNI16STANM USE 3.16HF008UNI24(E)LU URU 3.15HF008UNI24(E)NM URE 3.15HF008UNI24LSTALU USU2 3.17HF008UNI24LU UDU 3.14HF008UNI24NM UDE 3.14HF008UNI24NMSTANM USE2 3.17HF008UNI24STALU USU 3.16HF008UNI24STANM USE 3.16HF008UNI4(E)LU URU 3.15HF008UNI4(E)NM URE 3.15HF008UNI4LSTALU USU2 3.17HF008UNI4LU UDU 3.14HF008UNI4NM UDE 3.14HF008UNI4NMSTANM USE2 3.17HF008UNI4STALU USU 3.16HF008UNI4STANM USE 3.16HF008UNI6(E)LU URU 3.15HF008UNI6(E)NM URE 3.15HF008UNI6LSTALU USU2 3.17HF008UNI6LU UDU 3.14HF008UNI6NM UDE 3.14HF008UNI6NMSTANM USE2 3.17HF008UNI6STALU USU 3.16HF008UNI6STANM USE 3.16HF008UNI8(E)LU URU 3.15HF008UNI8(E)NM URE 3.15HF008UNI8LSTALU USU2 3.17HF008UNI8LU UDU 3.14HF008UNI8NM UDE 3.14HF008UNI8NMSTANM USE2 3.17HF008UNI8STALU USU 3.16HF008UNI8STANM USE 3.16HF050C12LU PDS 3.8HF050C16LU PDS 3.8HF050C24LU PDS 3.8HF050C2LU PDS 3.8HF050C4LU PDS 3.8HF050C6LU PDS 3.8HF050C8LU PDS 3.8HF050S108W(E)LU MRU03 3.23HF050S108W(E)NM MRE03 3.23HF050S108WLSTALU MSU203 3.29HF050S108WLU MDU03 3.20HF050S108WMB MAE03 3.32HF050S108WNM MDE03 3.20HF050S108WNMSTANM MSE203 3.29HF050S108WSTALU MSU03 3.26HF050S108WSTANM MSE03 3.26HF050S120W(E)LU MRU03 3.23HF050S120W(E)NM MRE03 3.23HF050S120WLSTALU MSU203 3.29HF050S120WLU MDU03 3.20HF050S120WMB MAE03 3.32HF050S120WNM MDE03 3.20HF050S120WNMSTANM MSE203 3.29HF050S120WSTALU MSU03 3.26HF050S120WSTANM MSE03 3.26HF050S12W(E)LU MRU01 3.21HF050S12W(E)LU MRU02 3.22HF050S12W(E)NM MRE01 3.21HF050S12W(E)NM MRE02 3.22HF050S12WLSTALU MSU201 3.27HF050S12WLSTALU MSU202 3.28HF050S12WLU MDU01 3.18HF050S12WLU MDU02 3.19HF050S12WMB MAE01 3.30HF050S12WMB MAE02 3.31HF050S12WNM MDE01 3.18HF050S12WNM MDE02 3.19HF050S12WNMSTANM MSE201 3.27
HF050S12WNMSTANM MSE202 3.28HF050S12WSTALU MSU01 3.24HF050S12WSTALU MSU02 3.25HF050S12WSTANM MSE01 3.24HF050S12WSTANM MSE02 3.25HF050S132W(E)LU MRU03 3.23HF050S132W(E)NM MRE03 3.23HF050S132WLSTALU MSU203 3.29HF050S132WLU MDU03 3.20HF050S132WMB MAE03 3.32HF050S132WNM MDE03 3.20HF050S132WNMSTANM MSE203 3.29HF050S132WSTALU MSU03 3.26HF050S132WSTANM MSE03 3.26HF050S144W(E)LU MRU03 3.23HF050S144W(E)NM MRE03 3.23HF050S144WLSTALU MSU203 3.29HF050S144WLU MDU03 3.20HF050S144WMB MAE03 3.32HF050S144WNM MDE03 3.20HF050S144WNMSTANM MSE203 3.29HF050S144WSTALU MSU03 3.26HF050S144WSTANM MSE03 3.26HF050S16W(E)LU MRU01 3.21HF050S16W(E)NM MRE01 3.21HF050S16WLSTALU MSU201 3.27HF050S16WLU MDU01 3.18HF050S16WMB MAE01 3.30HF050S16WNM MDE01 3.18HF050S16WNMSTANM MSE201 3.27HF050S16WSTALU MSU01 3.24HF050S16WSTANM MSE01 3.24HF050S20W(E)LU MRU01 3.21HF050S20W(E)NM MRE01 3.21HF050S20WLSTALU MSU201 3.27HF050S20WLU MDU01 3.18HF050S20WMB MAE01 3.30HF050S20WNM MDE01 3.18HF050S20WNMSTANM MSE201 3.27HF050S20WSTALU MSU01 3.24HF050S20WSTANM MSE01 3.24HF050S24W(E)LU MRU01 3.21HF050S24W(E)LU MRU02 3.22HF050S24W(E)NM MRE01 3.21HF050S24W(E)NM MRE02 3.22HF050S24WLSTALU MSU201 3.27HF050S24WLSTALU MSU202 3.28HF050S24WLU MDU01 3.18HF050S24WLU MDU02 3.19HF050S24WMB MAE01 3.30HF050S24WMB MAE02 3.31HF050S24WNM MDE01 3.18HF050S24WNM MDE02 3.19HF050S24WNMSTANM MSE201 3.27HF050S24WNMSTANM MSE202 3.28HF050S24WSTALU MSU01 3.24HF050S24WSTALU MSU02 3.25HF050S24WSTANM MSE01 3.24HF050S24WSTANM MSE02 3.25HF050S36W(E)LU MRU02 3.22HF050S36W(E)NM MRE02 3.22HF050S36WLSTALU MSU202 3.28HF050S36WLU MDU02 3.19HF050S36WMB MAE02 3.31HF050S36WNM MDE02 3.19HF050S36WNMSTANM MSE202 3.28HF050S36WSTALU MSU02 3.25HF050S36WSTANM MSE02 3.25HF050S48W(E)LU MRU02 3.22HF050S48W(E)NM MRE02 3.22HF050S48WLSTALU MSU202 3.28HF050S48WLU MDU02 3.19HF050S48WMB MAE02 3.31HF050S48WNM MDE02 3.19HF050S48WNMSTANM MSE202 3.28HF050S48WSTALU MSU02 3.25HF050S48WSTANM MSE02 3.25
Productpartnumber Page Productpartnumber Page Productpartnumber Page
Product Part Number Index
HF050S4W(E)LU MRU01 3.21HF050S4W(E)NM MRE01 3.21HF050S4WLSTALU MSU201 3.27HF050S4WLU MDU01 3.18HF050S4WMB MAE01 3.30HF050S4WNM MDE01 3.18HF050S4WNMSTANM MSE201 3.27HF050S4WSTALU MSU01 3.24HF050S4WSTANM MSE01 3.24HF050S60W(E)LU MRU02 3.22HF050S60W(E)NM MRE02 3.22HF050S60WLSTALU MSU202 3.28HF050S60WLU MDU02 3.19HF050S60WMB MAE02 3.31HF050S60WNM MDE02 3.19HF050S60WNMSTANM MSE202 3.28HF050S60WSTALU MSU02 3.25HF050S60WSTANM MSE02 3.25HF050S72W(E)LU MRU02 3.22HF050S72W(E)NM MRE02 3.22HF050S72WLSTALU MSU202 3.28HF050S72WLU MDU02 3.19HF050S72WMB MAE02 3.31HF050S72WNM MDE02 3.19HF050S72WNMSTANM MSE202 3.28HF050S72WSTALU MSU02 3.25HF050S72WSTANM MSE02 3.25HF050S8W(E)LU MRU01 3.21HF050S8W(E)NM MRE01 3.21HF050S8WLSTALU MSU201 3.27HF050S8WLU MDU01 3.18HF050S8WMB MAE01 3.30HF050S8WNM MDE01 3.18HF050S8WNMSTANM MSE201 3.27HF050S8WSTALU MSU01 3.24HF050S8WSTANM MSE01 3.24HF050S96W(E)LU MRU03 3.23HF050S96W(E)NM MRE03 3.23HF050S96WLSTALU MSU203 3.29HF050S96WLU MDU03 3.20HF050S96WMB MAE03 3.32HF050S96WNM MDE03 3.20HF050S96WNMSTANM MSE203 3.29HF050S96WSTALU MSU03 3.26HF050S96WSTANM MSE03 3.26HF050T12LU BKO 3.12HF050T16LU BKO 3.12HF050T1L SFC 3.10HF050T24LU BKO 3.12HF050T2L DUP 3.11HF050T2ZL ZIP 3.10HF050T4LU BKO 3.12HF050T6LU BKO 3.12HF050T8LU BKO 3.12HF050UNI12(E)LU URU 3.15HF050UNI12(E)NM URE 3.15HF050UNI12LSTALU USU2 3.17HF050UNI12LU UDU 3.14HF050UNI12NM UDE 3.14HF050UNI12NMSTANM USE2 3.17HF050UNI12STALU USU 3.16HF050UNI12STANM USE 3.16HF050UNI16(E)LU URU 3.15HF050UNI16(E)NM URE 3.15HF050UNI16LSTALU USU2 3.17HF050UNI16LU UDU 3.14HF050UNI16NM UDE 3.14HF050UNI16NMSTANM USE2 3.17HF050UNI16STALU USU 3.16HF050UNI16STANM USE 3.16HF050UNI24(E)LU URU 3.15HF050UNI24(E)NM URE 3.15HF050UNI24LSTALU USU2 3.17HF050UNI24LU UDU 3.14HF050UNI24NM UDE 3.14HF050UNI24NMSTANM USE2 3.17HF050UNI24STALU USU 3.16
HF050UNI24STANM USE 3.16HF050UNI4(E)LU URU 3.15HF050UNI4(E)NM URE 3.15HF050UNI4LSTALU USU2 3.17HF050UNI4LU UDU 3.14HF050UNI4NM UDE 3.14HF050UNI4NMSTANM USE2 3.17HF050UNI4STALU USU 3.16HF050UNI4STANM USE 3.16HF050UNI6(E)LU URU 3.15HF050UNI6(E)NM URE 3.15HF050UNI6LSTALU USU2 3.17HF050UNI6LU UDU 3.14HF050UNI6NM UDE 3.14HF050UNI6NMSTANM USE2 3.17HF050UNI6STALU USU 3.16HF050UNI6STANM USE 3.16HF050UNI8(E)LU URU 3.15HF050UNI8(E)NM URE 3.15HF050UNI8LSTALU USU2 3.17HF050UNI8LU UDU 3.14HF050UNI8NM UDE 3.14HF050UNI8NMSTANM USE2 3.17HF050UNI8STALU USU 3.16HF050UNI8STANM USE 3.16HF062C12LU PDS 3.8HF062C16LU PDS 3.8HF062C24LU PDS 3.8HF062C2LU PDS 3.8HF062C4LU PDS 3.8HF062C6LU PDS 3.8HF062C8LU PDS 3.8HF062S108W(E)LU MRU03 3.23HF062S108W(E)NM MRE03 3.23HF062S108WLSTALU MSU203 3.29HF062S108WLU MDU03 3.20HF062S108WMB MAE03 3.32HF062S108WNM MDE03 3.20HF062S108WNMSTANM MSE203 3.29HF0å62S108WSTALU MSU03 3.26HF062S108WSTANM MSE03 3.26HF062S120W(E)LU MRU03 3.23HF062S120W(E)NM MRE03 3.23HF062S120WLSTALU MSU203 3.29HF062S120WLU MDU03 3.20HF062S120WMB MAE03 3.32HF062S120WNM MDE03 3.20HF062S120WNMSTANM MSE203 3.29HF062S120WSTALU MSU03 3.26HF062S120WSTANM MSE03 3.26HF062S12W(E)LU MRU01 3.21HF062S12W(E)LU MRU02 3.22HF062S12W(E)NM MRE01 3.21HF062S12W(E)NM MRE02 3.22HF062S12WLSTALU MSU201 3.27HF062S12WLSTALU MSU202 3.28HF062S12WLU MDU01 3.18HF062S12WLU MDU02 3.19HF062S12WMB MAE01 3.30HF062S12WMB MAE02 3.31HF062S12WNM MDE01 3.18HF062S12WNM MDE02 3.19HF062S12WNMSTANM MSE201 3.27HF062S12WNMSTANM MSE202 3.28HF062S12WSTALU MSU01 3.24HF062S12WSTALU MSU02 3.25HF062S12WSTANM MSE01 3.24HF062S12WSTANM MSE02 3.25HF062S132W(E)LU MRU03 3.23HF062S132W(E)NM MRE03 3.23HF062S132WLSTALU MSU203 3.29HF062S132WLU MDU03 3.20HF062S132WMB MAE03 3.32HF062S132WNM MDE03 3.20HF062S132WNMSTANM MSE203 3.29HF062S132WSTALU MSU03 3.26HF062S132WSTANM MSE03 3.26
HF062S144W(E)LU MRU03 3.23HF062S144W(E)NM MRE03 3.23HF062S144WLSTALU MSU203 3.29HF062S144WLU MDU03 3.20HF062S144WMB MAE03 3.32HF062S144WNM MDE03 3.20HF062S144WNMSTANM MSE203 3.29HF062S144WSTALU MSU03 3.26HF062S144WSTANM MSE03 3.26HF062S16W(E)LU MRU01 3.21HF062S16W(E)NM MRE01 3.21HF062S16WLSTALU MSU201 3.27HF062S16WLU MDU01 3.18HF062S16WMB MAE01 3.30HF062S16WNM MDE01 3.18HF062S16WNMSTANM MSE201 3.27HF062S16WSTALU MSU01 3.24HF062S16WSTANM MSE01 3.24HF062S20W(E)LU MRU01 3.21HF062S20W(E)NM MRE01 3.21HF062S20WLSTALU MSU201 3.27HF062S20WLU MDU01 3.18HF062S20WMB MAE01 3.30HF062S20WNM MDE01 3.18HF062S20WNMSTANM MSE201 3.27HF062S20WSTALU MSU01 3.24HF062S20WSTANM MSE01 3.24HF062S24W(E)LU MRU01 3.21HF062S24W(E)LU MRU02 3.22HF062S24W(E)NM MRE01 3.21HF062S24W(E)NM MRE02 3.22HF062S24WLSTALU MSU201 3.27HF062S24WLSTALU MSU202 3.28HF062S24WLU MDU01 3.18HF062S24WLU MDU02 3.19HF062S24WMB MAE01 3.30HF062S24WMB MAE02 3.31HF062S24WNM MDE01 3.18HF062S24WNM MDE02 3.19HF062S24WNMSTANM MSE201 3.27HF062S24WNMSTANM MSE202 3.28HF062S24WSTALU MSU01 3.24HF062S24WSTALU MSU02 3.25HF062S24WSTANM MSE01 3.24HF062S24WSTANM MSE02 3.25HF062S36W(E)LU MRU02 3.22HF062S36W(E)NM MRE02 3.22HF062S36WLSTALU MSU202 3.28HF062S36WLU MDU02 3.19HF062S36WMB MAE02 3.31HF062S36WNM MDE02 3.19HF062S36WNMSTANM MSE202 3.28HF062S36WSTALU MSU02 3.25HF062S36WSTANM MSE02 3.25HF062S48W(E)LU MRU02 3.22HF062S48W(E)NM MRE02 3.22HF062S48WLSTALU MSU202 3.28HF062S48WLU MDU02 3.19HF062S48WMB MAE02 3.31HF062S48WNM MDE02 3.19HF062S48WNMSTANM MSE202 3.28HF062S48WSTALU MSU02 3.25HF062S48WSTANM MSE02 3.25HF062S4W(E)LU MRU01 3.21HF062S4W(E)NM MRE01 3.21HF062S4WLSTALU MSU201 3.27HF062S4WLU MDU01 3.18HF062S4WMB MAE01 3.30HF062S4WNM MDE01 3.18HF062S4WNMSTANM MSE201 3.27HF062S4WSTALU MSU01 3.24HF062S4WSTANM MSE01 3.24HF062S60W(E)LU MRU02 3.22HF062S60W(E)NM MRE02 3.22HF062S60WLSTALU MSU202 3.28HF062S60WLU MDU02 3.19HF062S60WMB MAE02 3.31
Productpartnumber Page Productpartnumber Page Productpartnumber Page
Product Part Number Index
HF062S60WNM MDE02 3.19HF062S60WNMSTANM MSE202 3.28HF062S60WSTALU MSU02 3.25HF062S60WSTANM MSE02 3.25HF062S72W(E)LU MRU02 3.22HF062S72W(E)NM MRE02 3.22HF062S72WLSTALU MSU202 3.28HF062S72WLU MDU02 3.19HF062S72WMB MAE02 3.31HF062S72WNM MDE02 3.19HF062S72WNMSTANM MSE202 3.28HF062S72WSTALU MSU02 3.25HF062S72WSTANM MSE02 3.25HF062S8W(E)LU MRU01 3.21HF062S8W(E)NM MRE01 3.21HF062S8WLSTALU MSU201 3.27HF062S8WLU MDU01 3.18HF062S8WMB MAE01 3.30HF062S8WNM MDE01 3.18HF062S8WNMSTANM MSE201 3.27HF062S8WSTALU MSU01 3.24HF062S8WSTANM MSE01 3.24HF062S96W(E)LU MRU03 3.23HF062S96W(E)NM MRE03 3.23HF062S96WLSTALU MSU203 3.29HF062S96WLU MDU03 3.20HF062S96WMB MAE03 3.32HF062S96WNM MDE03 3.20HF062S96WNMSTANM MSE203 3.29HF062S96WSTALU MSU03 3.26HF062S96WSTANM MSE03 3.26HF062T12LU BKO 3.12HF062T16LU BKO 3.12HF062T1L SFC 3.10HF062T24LU BKO 3.12HF062T2L DUP 3.11HF062T2ZL ZIP 3.10HF062T4LU BKO 3.12HF062T6LU BKO 3.12HF062T8LU BKO 3.12HF062UNI12(E)LU URU 3.15HF062UNI12(E)NM URE 3.15HF062UNI12LSTALU USU2 3.17HF062UNI12LU UDU 3.14HF062UNI12NM UDE 3.14HF062UNI12NMSTANM USE2 3.17HF062UNI12STALU USU 3.16HF062UNI12STANM USE 3.16HF062UNI16(E)LU URU 3.15HF062UNI16(E)NM URE 3.15HF062UNI16LSTALU USU2 3.17HF062UNI16LU UDU 3.14HF062UNI16NM UDE 3.14HF062UNI16NMSTANM USE2 3.17HF062UNI16STALU USU 3.16HF062UNI16STANM USE 3.16HF062UNI24(E)LU URU 3.15HF062UNI24(E)NM URE 3.15HF062UNI24LSTALU USU2 3.17HF062UNI24LU UDU 3.14HF062UNI24NM UDE 3.14HF062UNI24NMSTANM USE2 3.17HF062UNI24STALU USU 3.16HF062UNI24STANM USE 3.16HF062UNI4(E)LU URU 3.15HF062UNI4(E)NM URE 3.15HF062UNI4LSTALU USU2 3.17HF062UNI4LU UDU 3.14HF062UNI4NM UDE 3.14HF062UNI4NMSTANM USE2 3.17HF062UNI4STALU USU 3.16HF062UNI4STANM USE 3.16HF062UNI6(E)LU URU 3.15HF062UNI6(E)NM URE 3.15HF062UNI6LSTALU USU2 3.17HF062UNI6LU UDU 3.14HF062UNI6NM UDE 3.14
HF062UNI6NMSTANM USE2 3.17HF062UNI6STALU USU 3.16HF062UNI6STANM USE 3.16HF062UNI8(E)LU URU 3.15HF062UNI8(E)NM URE 3.15HF062UNI8LSTALU USU2 3.17HF062UNI8LU UDU 3.14HF062UNI8NM UDE 3.14HF062UNI8NMSTANM USE2 3.17HF062UNI8STALU USU 3.16HF062UNI8STANM USE 3.16HFOM3C12LU PDS 3.8HFOM3C16LU PDS 3.8HFOM3C24LU PDS 3.8HFOM3C2LU PDS 3.8HFOM3C4LU PDS 3.8HFOM3C6LU PDS 3.8HFOM3C8LU PDS 3.8HFOM3S108W(E)LU MRU03 3.23HFOM3S108W(E)NM MRE03 3.23HFOM3S108WLSTALU MSU203 3.29HFOM3S108WLU MDU03 3.20HFOM3S108WMB MAE03 3.32HFOM3S108WNM MDE03 3.20HFOM3S108WNMSTANM MSE203 3.29HFOM3S108WSTALU MSU03 3.26HFOM3S108WSTANM MSE03 3.26HFOM3S120W(E)LU MRU03 3.23HFOM3S120W(E)NM MRE03 3.23HFOM3S120WLSTALU MSU203 3.29HFOM3S120WLU MDU03 3.20HFOM3S120WMB MAE03 3.32HFOM3S120WNM MDE03 3.20HFOM3S120WNMSTANM MSE203 3.29HFOM3S120WSTALU MSU03 3.26HFOM3S120WSTANM MSE03 3.26HFOM3S12W(E)LU MRU01 3.21HFOM3S12W(E)LU MRU02 3.22HFOM3S12W(E)NM MRE01 3.21HFOM3S12W(E)NM MRE02 3.22HFOM3S12WLSTALU MSU201 3.27HFOM3S12WLSTALU MSU202 3.28HFOM3S12WLU MDU01 3.18HFOM3S12WLU MDU02 3.19HFOM3S12WMB MAE01 3.30HFOM3S12WMB MAE02 3.31HFOM3S12WNM MDE01 3.18HFOM3S12WNM MDE02 3.19HFOM3S12WNMSTANM MSE201 3.27HFOM3S12WNMSTANM MSE202 3.28HFOM3S12WSTALU MSU01 3.24HFOM3S12WSTALU MSU02 3.25HFOM3S12WSTANM MSE01 3.24HFOM3S12WSTANM MSE02 3.25HFOM3S132W(E)LU MRU03 3.23HFOM3S132W(E)NM MRE03 3.23HFOM3S132WLSTALU MSU203 3.29HFOM3S132WLU MDU03 3.20HFOM3S132WMB MAE03 3.32HFOM3S132WNM MDE03 3.20HFOM3S132WNMSTANM MSE203 3.29HFOM3S132WSTALU MSU03 3.26HFOM3S132WSTANM MSE03 3.26HFOM3S144W(E)LU MRU03 3.23HFOM3S144W(E)NM MRE03 3.23HFOM3S144WLSTALU MSU203 3.29HFOM3S144WLU MDU03 3.20HFOM3S144WMB MAE03 3.32HFOM3S144WNM MDE03 3.20HFOM3S144WNMSTANM MSE203 3.29HFOM3S144WSTALU MSU03 3.26HFOM3S144WSTANM MSE03 3.26HFOM3S16W(E)LU MRU01 3.21HFOM3S16W(E)NM MRE01 3.21HFOM3S16WLSTALU MSU201 3.27HFOM3S16WLU MDU01 3.18HFOM3S16WMB MAE01 3.30
HFOM3S16WNM MDE01 3.18HFOM3S16WNMSTANM MSE201 3.27HFOM3S16WSTALU MSU01 3.24HFOM3S16WSTANM MSE01 3.24HFOM3S20W(E)LU MRU01 3.21HFOM3S20W(E)NM MRE01 3.21HFOM3S20WLSTALU MSU201 3.27HFOM3S20WLU MDU01 3.18HFOM3S20WMB MAE01 3.30HFOM3S20WNM MDE01 3.18HFOM3S20WNMSTANM MSE201 3.27HFOM3S20WSTALU MSU01 3.24HFOM3S20WSTANM MSE01 3.24HFOM3S24W(E)LU MRU01 3.21HFOM3S24W(E)LU MRU02 3.22HFOM3S24W(E)NM MRE01 3.21HFOM3S24W(E)NM MRE02 3.22HFOM3S24WLSTALU MSU201 3.27HFOM3S24WLSTALU MSU202 3.28HFOM3S24WLU MDU01 3.18HFOM3S24WLU MDU02 3.19HFOM3S24WMB MAE01 3.30HFOM3S24WMB MAE02 3.31HFOM3S24WNM MDE01 3.18HFOM3S24WNM MDE02 3.19HFOM3S24WNMSTANM MSE201 3.27HFOM3S24WNMSTANM MSE202 3.28HFOM3S24WSTALU MSU01 3.24HFOM3S24WSTALU MSU02 3.25HFOM3S24WSTANM MSE01 3.24HFOM3S24WSTANM MSE02 3.25HFOM3S36W(E)LU MRU02 3.22HFOM3S36W(E)NM MRE02 3.22HFOM3S36WLSTALU MSU202 3.28HFOM3S36WLU MDU02 3.19HFOM3S36WMB MAE02 3.31HFOM3S36WNM MDE02 3.19HFOM3S36WNMSTANM MSE202 3.28HFOM3S36WSTALU MSU02 3.25HFOM3S36WSTANM MSE02 3.25HFOM3S48W(E)LU MRU02 3.22HFOM3S48W(E)NM MRE02 3.22HFOM3S48WLSTALU MSU202 3.28HFOM3S48WLU MDU02 3.19HFOM3S48WMB MAE02 3.31HFOM3S48WNM MDE02 3.19HFOM3S48WNMSTANM MSE202 3.28HFOM3S48WSTALU MSU02 3.25HFOM3S48WSTANM MSE02 3.25HFOM3S4W(E)LU MRU01 3.21HFOM3S4W(E)NM MRE01 3.21HFOM3S4WLSTALU MSU201 3.27HFOM3S4WLU MDU01 3.18HFOM3S4WMB MAE01 3.30HFOM3S4WNM MDE01 3.18HFOM3S4WNMSTANM MSE201 3.27HFOM3S4WSTALU MSU01 3.24HFOM3S4WSTANM MSE01 3.24HFOM3S60W(E)LU MRU02 3.22HFOM3S60W(E)NM MRE02 3.22HFOM3S60WLSTALU MSU202 3.28HFOM3S60WLU MDU02 3.19HFOM3S60WMB MAE02 3.31HFOM3S60WNM MDE02 3.19HFOM3S60WNMSTANM MSE202 3.28HFOM3S60WSTALU MSU02 3.25HFOM3S60WSTANM MSE02 3.25HFOM3S72W(E)LU MRU02 3.22HFOM3S72W(E)NM MRE02 3.22HFOM3S72WLSTALU MSU202 3.28HFOM3S72WLU MDU02 3.19HFOM3S72WMB MAE02 3.31HFOM3S72WNM MDE02 3.19HFOM3S72WNMSTANM MSE202 3.28HFOM3S72WSTALU MSU02 3.25HFOM3S72WSTANM MSE02 3.25HFOM3S8W(E)LU MRU01 3.21
Productpartnumber Page Productpartnumber Page Productpartnumber Page
Product Part Number Index
HFOM3S8W(E)NM MRE01 3.21HFOM3S8WLSTALU MSU201 3.27HFOM3S8WLU MDU01 3.18HFOM3S8WMB MAE01 3.30HFOM3S8WNM MDE01 3.18HFOM3S8WNMSTANM MSE201 3.27HFOM3S8WSTALU MSU01 3.24HFOM3S8WSTANM MSE01 3.24HFOM3S96W(E)LU MRU03 3.23HFOM3S96W(E)NM MRE03 3.23HFOM3S96WLSTALU MSU203 3.29HFOM3S96WLU MDU03 3.20HFOM3S96WMB MAE03 3.32HFOM3S96WNM MDE03 3.20HFOM3S96WNMSTANM MSE203 3.29HFOM3S96WSTALU MSU03 3.26HFOM3S96WSTANM MSE03 3.26HFOM3T12LU BKO 3.12HFOM3T16LU BKO 3.12HFOM3T1L SFC 3.10HFOM3T24LU BKO 3.12HFOM3T2L DUP 3.11HFOM3T2ZL ZIP 3.10HFOM3T4LU BKO 3.12HFOM3T6LU BKO 3.12HFOM3T8LU BKO 3.12HFOM3UNI12(E)LU URU 3.15HFOM3UNI12(E)NM URE 3.15HFOM3UNI12LSTALU USU2 3.17HFOM3UNI12LU UDU 3.14HFOM3UNI12NM UDE 3.14HFOM3UNI12NMSTANM USE2 3.17HFOM3UNI12STALU USU 3.16HFOM3UNI12STANM USE 3.16HFOM3UNI16(E)LU URU 3.15HFOM3UNI16(E)NM URE 3.15HFOM3UNI16LSTALU USU2 3.17HFOM3UNI16LU UDU 3.14HFOM3UNI16NM UDE 3.14HFOM3UNI16NMSTANM USE2 3.17HFOM3UNI16STALU USU 3.16HFOM3UNI16STANM USE 3.16HFOM3UNI24(E)LU URU 3.15HFOM3UNI24(E)NM URE 3.15HFOM3UNI24LSTALU USU2 3.17HFOM3UNI24LU UDU 3.14HFOM3UNI24NM UDE 3.14HFOM3UNI24NMSTANM USE2 3.17HFOM3UNI24STALU USU 3.16HFOM3UNI24STANM USE 3.16HFOM3UNI4(E)LU URU 3.15HFOM3UNI4(E)NM URE 3.15HFOM3UNI4LSTALU USU2 3.17HFOM3UNI4LU UDU 3.14HFOM3UNI4NM UDE 3.14HFOM3UNI4NMSTANM USE2 3.17HFOM3UNI4STALU USU 3.16HFOM3UNI4STANM USE 3.16
HFOM3UNI6(E)LU URU 3.15HFOM3UNI6(E)NM URE 3.15HFOM3UNI6LSTALU USU2 3.17HFOM3UNI6LU UDU 3.14HFOM3UNI6NM UDE 3.14HFOM3UNI6NMSTANM USE2 3.17HFOM3UNI6STALU USU 3.16HFOM3UNI6STANM USE 3.16HFOM3UNI8(E)LU URU 3.15HFOM3UNI8(E)NM URE 3.15HFOM3UNI8LSTALU USU2 3.17HFOM3UNI8LU UDU 3.14HFOM3UNI8NM UDE 3.14HFOM3UNI8NMSTANM USE2 3.17HFOM3UNI8STALU USU 3.16HFOM3UNI8STANM USE 3.16HOPXX008010XXXXX 3.37HOPXX008020XXXXX 3.37HOPXX008030XXXXX 3.37HOPXX008050XXXXX 3.37HOPXX050010XXXXX 3.35HOPXX050020XXXXX 3.35HOPXX050030XXXXX 3.35HOPXX050050XXXXX 3.35HOPXX062010XXXXX 3.34HOPXX062020XXXXX 3.34HOPXX062030XXXXX 3.34HOPXX062050XXXXX 3.34HOPXXOM3010XXXXX 3.36HOPXXOM3020XXXXX 3.36HOPXXOM3030XXXXX 3.36HOPXXOM3050XXXXX 3.36HOTXX008XXX 3.38HOTXX050XXX 3.38HOTXX062XXX 3.38HOTXXOM3XXX 3.38MFCBBLK001 3.39MFCBKIT001 3.39MFCC15XXX48SC2 3.39MFCC1SXMM04DC2 3.40MFCC1SXMM04SC2 3.40MFCC1SXMM04ST2 3.40MFCC1SXMM06DC2 3.40MFCC1SXMM06SC2 3.40MFCC1SXMM06ST2 3.40MFCC1SXMM08DC2 3.40MFCC1SXMM08LC2 3.40MFCC1SXMM08SC2 3.40MFCC1SXMM08ST2 3.40MFCC1SXMM12DC2 3.40MFCC1SXMM12LC2 3.40MFCC1SXMM12SC2 3.40MFCC1SXMM12ST2 3.40MFCC1SXMM16DC2 3.40MFCC1SXMM16LC2 3.40MFCC1SXMM16SC2 3.40MFCC1SXMM16ST2 3.40MFCC1SXMM24DC2 3.40
MFCC1SXMM24LC2 3.40MFCC1SXMM24SC2 3.40MFCC1SXMM24ST2 3.40MFCC1SXMM32LC2 3.40MFCC1SXMM48LC2 3.40MFCC1SXSM04DC2 3.40MFCC1SXSM04FC2 3.40MFCC1SXSM04SC2 3.40MFCC1SXSM04ST2 3.40MFCC1SXSM06DC2 3.40MFCC1SXSM06FC2 3.40MFCC1SXSM06SC2 3.40MFCC1SXSM06ST2 3.40MFCC1SXSM08DC2 3.40MFCC1SXSM08FC2 3.40MFCC1SXSM08LC2 3.40MFCC1SXSM08SC2 3.40MFCC1SXSM08ST2 3.40MFCC1SXSM12DC2 3.40MFCC1SXSM12FC2 3.40MFCC1SXSM12LC2 3.40MFCC1SXSM12SC2 3.40MFCC1SXSM12ST2 3.40MFCC1SXSM16DC2 3.40MFCC1SXSM16FC2 3.40MFCC1SXSM16LC2 3.40MFCC1SXSM16SC2 3.40MFCC1SXSM16ST2 3.40MFCC1SXSM24DC2 3.40MFCC1SXSM24FC2 3.40MFCC1SXSM24LC2 3.40MFCC1SXSM24SC2 3.40MFCC1SXSM24ST2 3.40MFCC1SXSM32LC2 3.40MFCC1SXSM48LC2 3.40MFCC1SXXM08MJ2 3.40MFCC1SXXM12MJ2 3.40MFCC1SXXM16MJ2 3.40MFCC1SXXM24MJ2 3.40MFCC1SXXM32MJ2 3.40MFCC1SXXM48MJ2 3.40MFCC1SXXX24DC2 3.39MFCC1SXXX24ST2 3.39MFCDCMM001 3.44MFCDCSM001 3.44MFCFCSM001 3.44MFCFMKIT001 3.39MFCFMKIT002 3.39MFCFMKIT003 3.39MFCFMKIT004 3.39MFCLCMM001 3.44MFCLCSM001 3.44MFCMJXM001 3.44MFCSTMM001 3.44MFCSTSM001 3.44TDC2W 3.44