optical fiber cable itu-t sg15question 15 g[1].650 series

7

Click here to load reader

Upload: wholenumber

Post on 27-Nov-2014

31 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Optical Fiber Cable ITU-T SG15Question 15 G[1].650 Series

Evolution of Optical Fibre Types and Cables

Evolution of Optical Fibre Types and Cables

Jim Matthews IIICorning Incorporated

Jim Matthews IIICorning Incorporated

Page 2: Optical Fiber Cable ITU-T SG15Question 15 G[1].650 Series

Standards EngineeringCorning Incorporated

Optical Fiber & Cable ITU-T SG15/Question 15: G.650 Series Recommendations Optical Fiber & Cable ITU-T SG15/Question 15: G.650 Series Recommendations

• G.650 Definition and test methods for the relevant parameters of single-mode fibres

• G.651 Characteristics of a 50/125 µm multimode graded index optical fibre cable

• G.652 Characteristics of a single-mode optical fibre cable• G.653 Characteristics of a dispersion-shifted single-mode optical

fiber cable• G.654 Characteristics of a cut-off shifted single-mode optical fibre

cable• G.655 Characteristics of a non-zero dispersion shifted single-mode

optical fibre cable• G.scl Characteristics of a fibre and cable with non-zero dispersion for

broadband optical transport

• G.650 Definition and test methods for the relevant parameters of single-mode fibres

• G.651 Characteristics of a 50/125 µm multimode graded index optical fibre cable

• G.652 Characteristics of a single-mode optical fibre cable• G.653 Characteristics of a dispersion-shifted single-mode optical

fiber cable• G.654 Characteristics of a cut-off shifted single-mode optical fibre

cable• G.655 Characteristics of a non-zero dispersion shifted single-mode

optical fibre cable• G.scl Characteristics of a fibre and cable with non-zero dispersion for

broadband optical transport

Page 3: Optical Fiber Cable ITU-T SG15Question 15 G[1].650 Series

Standards EngineeringCorning Incorporated

Current Optical Fiber & Cable Activities (SG15)Current Optical Fiber & Cable Activities (SG15)

• The Recommendation on SM Test Methods was subdivided into three smaller Recommendations:– G.650.1 Definitions and test methods for linear, deterministic

attributes (consented)– G.650.2 Definitions and test methods for statistical and non-linear

attributes (consented)– G.650.3 Test methods for installed single-mode links (under

discussion)

• 40 GB/s applications facilitate PMD Discussions– PMDQ values Correspondence Group

• New fiber type - Draft Recommendation G.scl– Non-zero dispersion-shifted fiber that would operate in the S, C, and L

bands– Correspondence Group preparing a draft for the next mtg.

• The Recommendation on SM Test Methods was subdivided into three smaller Recommendations:– G.650.1 Definitions and test methods for linear, deterministic

attributes (consented)– G.650.2 Definitions and test methods for statistical and non-linear

attributes (consented)– G.650.3 Test methods for installed single-mode links (under

discussion)

• 40 GB/s applications facilitate PMD Discussions– PMDQ values Correspondence Group

• New fiber type - Draft Recommendation G.scl– Non-zero dispersion-shifted fiber that would operate in the S, C, and L

bands– Correspondence Group preparing a draft for the next mtg.

Page 4: Optical Fiber Cable ITU-T SG15Question 15 G[1].650 Series

Standards EngineeringCorning Incorporated

ITU-T Study Group 6 Outside PlantITU-T Study Group 6 Outside Plant

• 1/6 Environmental issues of telecommunication plant• 2/6 Fire safety of telecommunication installations• 3/6 Copper networks for shared multi- services in one multi-pair cable• 4/6 Infrastructure and installation considerations for cables and

equipment• 5/6 Optical fibre cable network maintenance• 6/6 Installation of underground telecommunication cables in small

trenches• 7/6 Joint closures, termination and distribution frames, outdoor

enclosures and passive components• 8/6 Optical fibre cable construction• 9/6 Construction of optical networks in the access area• 10/6 Marinized Terrestrial Cables as defined in ITU-T

Recommendation G.972

• 1/6 Environmental issues of telecommunication plant• 2/6 Fire safety of telecommunication installations• 3/6 Copper networks for shared multi- services in one multi-pair cable• 4/6 Infrastructure and installation considerations for cables and

equipment• 5/6 Optical fibre cable network maintenance• 6/6 Installation of underground telecommunication cables in small

trenches• 7/6 Joint closures, termination and distribution frames, outdoor

enclosures and passive components• 8/6 Optical fibre cable construction• 9/6 Construction of optical networks in the access area• 10/6 Marinized Terrestrial Cables as defined in ITU-T

Recommendation G.972

Page 5: Optical Fiber Cable ITU-T SG15Question 15 G[1].650 Series

Standards EngineeringCorning Incorporated

Current Activities - SG6 Outside PlantCurrent Activities - SG6 Outside Plant

• Focal point for global standards on Outside Plant– Access, metropolitan and inter-office (long-haul, core) and

MTCs– Installation, protection, maintenance of optical and other

transport networks, systems and equipment– Installation, protection and maintenance of cables, equipment

and accessories for access and long distance networks for new services

– Impact of the infrastructure on the environment– Handbooks– Revisions of L-Series Recommendations

• Focal point for global standards on Outside Plant– Access, metropolitan and inter-office (long-haul, core) and

MTCs– Installation, protection, maintenance of optical and other

transport networks, systems and equipment– Installation, protection and maintenance of cables, equipment

and accessories for access and long distance networks for new services

– Impact of the infrastructure on the environment– Handbooks– Revisions of L-Series Recommendations

Page 6: Optical Fiber Cable ITU-T SG15Question 15 G[1].650 Series

Standards EngineeringCorning Incorporated

New Collaboration Trial New Collaboration Trial

• New Discussion Group in SG 6 (e-mail exploder)

• Participating groups:

– ITU-T SG6

– IEC SC 86A Optical Fibres and Cables

– IEC SC 86B Optical Interconnecting Devices and Passive Components

– IEC SC 46C Wires and Symmetric Cables

• Objectives:

– Identify the areas of common interest

– Identify desired ways of cooperation and timescales

– Cooperation and planning of future work

• New Discussion Group in SG 6 (e-mail exploder)

• Participating groups:

– ITU-T SG6

– IEC SC 86A Optical Fibres and Cables

– IEC SC 86B Optical Interconnecting Devices and Passive Components

– IEC SC 46C Wires and Symmetric Cables

• Objectives:

– Identify the areas of common interest

– Identify desired ways of cooperation and timescales

– Cooperation and planning of future work

Page 7: Optical Fiber Cable ITU-T SG15Question 15 G[1].650 Series

Standards EngineeringCorning Incorporated

ConclusionsConclusions

• New Fibre Types– Broad range of applications – S, C, and L Bands

• New Fibre and Cable Specifications– Polarization Mode Dispersion, Chromatic Dispersion…..

• New Requirements and Techniques for Outside Plant– Installation, environmental, operational….

• New Working Methods and Collaboration– Efficiency, Speed, and Relevance

• New Fibre Types– Broad range of applications – S, C, and L Bands

• New Fibre and Cable Specifications– Polarization Mode Dispersion, Chromatic Dispersion…..

• New Requirements and Techniques for Outside Plant– Installation, environmental, operational….

• New Working Methods and Collaboration– Efficiency, Speed, and Relevance