operation of the fw-720 unit 1. side 1 2 inlet hand crank
TRANSCRIPT
![Page 1: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/1.jpg)
1Operation of the FW-720 Unit
![Page 2: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/2.jpg)
2
Side 1
Inlet
Hand Crank
![Page 3: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/3.jpg)
3
Side 2In
let
Discha
rge
Pump
Ball Valve
75 psi Pressu
re
Relief V
alve
Female
GHT
Inlet
Flow Restrictor
![Page 4: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/4.jpg)
4
Side 3
Removable Pump
![Page 5: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/5.jpg)
5
Side 4
Air Bleed Valve
Lamp out Solenoid
![Page 6: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/6.jpg)
6
PumpIntake Hose
(Could be a standard garden hose)
Pump
Discharge Hose
![Page 7: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/7.jpg)
7
Canisters and Filters
Canisters
Filters UV Bulb
![Page 8: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/8.jpg)
8Additional Components
Extension Cords Discharge Hose
Operation Manual
Canister WrenchQuick Setup Guide
Spare Quartz Sleeve or UV Bulb
![Page 9: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/9.jpg)
9Setup from Static Water Source
Source Water
Pump
Purification Unit
- Pump must be Primed -Remove Plug and Fill with Water
![Page 10: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/10.jpg)
10Setup – Directly From Building
Simply connect hose and turn water on
![Page 11: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/11.jpg)
11
Preparing the Unit• Make sure all canisters have new, clean filters in them• Disinfect all discharge outlets and hoses with a bleach / water
solution• A ¼ cup to 1 gallon of water solution is generally a good ratio
but use the ratio that is appropriate for your facility. Let sit in bleach water for 2 minutes.
![Page 12: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/12.jpg)
12
Priming the Pump• Prime pump
• Open priming plug and fill pump with water• Fill intake hose completely with water• Place foot valve into water source and
connect other end of hose to pump intake• Plug pump in to power source• Wait for pump to turn on and see if the
pump is primed.• If pump is not primed or loses the prime
repeat the above process until pump stays primed.
• Once pump is primed unplug pump to turn off then connect hose to pump discharge and the other end to the FW-720 intake.
Priming Plug
Drain Plug
![Page 13: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/13.jpg)
13
Turning the FW-720 On
• Once the FW-720 intake hose is connected, plug the UV power cord in.
• The blue lamp on the power supply should light up indicating the lamp is on.
Note:This picture shows the UV bulb illuminated. When in actual use the UV bulb will not be visible because it is inside a black canister.
Warning:Exposure to UV light can cause skin and eye damage. Do not look directly at the UV bulb.
![Page 14: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/14.jpg)
14
Flowing the FW-720
• Make sure a hose is connected to the FW-720 discharge outlet
• Plug the pump in to turn it on• Open the intake ball-valve• Allow water to flow for a minute to flush any debris out of
the system and hoses.
![Page 15: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/15.jpg)
15
Cleaning the FW-720• Turn unit off by unplugging the pump and the UV power supply• Disconnect all connections• Remove screen filter canister from pump. Rinse and clean screen filter. Drain and
dry canister.• Remove the drain and priming plug from pump . Allow water to fully drain from the
pump. Tilting the pump back and forth and side to side helps remove all water.• Replace drain plugs and screen filter after pump has drained.• Remove all filter canisters; remove and discard used filters; dry out the inside of the
canisters.• Open the intake ball valve and the air bleed valve. Tilt the unit back and forth until
the unit drains. If possible, allow the unit to air dry several days before replacing canisters.
• Drain hoses• Store the unit with no filters installed. Filters will be installed before the next use.• Clean the unit as good as possible. The unit can be disinfected at your discretion but
is not required. Disinfecting the unit is always done before it is used.
![Page 16: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank](https://reader035.vdocuments.site/reader035/viewer/2022070307/551b5b1a550346d31b8b556b/html5/thumbnails/16.jpg)
16Preventative Maintenance
• Plug the UV power supply in and make sure the bulb is working
• Remove canisters and make sure the O-rings are still lubricated
Every 6 months:
• Make sure all parts and hoses are with the unit and haven’t been lost or repurposed.