OPERATION GUIDE

7 Day Multi-stage/Heat PumpElectronic Digital Thermostat

1F94-80

WHITE-RODGERS

Operator: Save this booklet for future use!

W H I T E - R O D G E R SDIGITAL COMFORT SET II

Page 2: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

2

Please read this manual thoroughly before operating or programming your thermostat. If you havequestions, you may write to our Technical Service Department at the address shown on the backcover of this booklet.

About Your New Thermostat . . .

Your new Digital COMFORT SET II Multi-stage/Heat Pump Thermostat uses the technology of asolid-state microcomputer to provide precise time/temperature control. The COMFORT SET IIThermostat offers you the flexibility to design heating and cooling programs that fit your needs.

Page 3: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

3

PROGRAMMING YOURTHERMOSTAT ................................... 19PLANNING FOR YOUR NEEDSENTERING YOUR PROGRAM

Set Current Time and DayProgram Heating/Cooling

TemperaturesEnter Heating ProgramEnter Cooling ProgramUsing the HOLD/COPY Button

CHECK YOUR PROGRAMMINGQUESTIONS AND ANSWERS ................ 34

YOUR NEW THERMOSTAT'SFEATURES ........................................... 4

OPERATING YOUR THERMOSTAT ........ 5PARTS OF THE THERMOSTAT

The Back Of the Thermostat BodyThe DisplayThe Thermostat Buttons

OPERATING FEATURES

In This Guide . . .

Operator: Save thisbooklet for future use!

Page 4: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

4

• Computed Energy Management Recovery(EMR)

• Automatic changeover (operator-selectable)• Separate setback programming for 7 inde-

pendent days• Simultaneous heat and cool program stor-

age• Two separate time/temperature settings per

24-hour period (occupied and unoccupied)• Armchair programming capability• Up to 2 stages of heat and up to 2 stages of

cool• Damper control and programmable fan when

the occupied temperature is selected• Backlit LCD displays continuous set point,

time, and room temperature

• 9 volt Energizer® alkaline battery backup• Preprogrammed temperature control• Adjustable cycle times• Compressor short cycle protection• Blower delay in the cooling cycle• Audio and visual prompting during opera-

tion• Two hour temperature override• Manual program override (HOLD tempera-

ture)• °F/°C convertibility• Keypad lockout (operator-selectable)• Temperature range 40° to 99°F• Compatible with Remote Sensor (installer-

selectable)

YOUR NEW THERMOSTAT’S FEATURES

Page 5: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

5

OPERATING YOUR THERMOSTAT

The subbase is attached to the wall, but you canremove the thermostat body for easy program-ming. To remove the thermostat body from thesubbase, grasp the thermostat body and gentlypull it out from the bottom of the subbase andpivot up. To attach the thermostat body, line upthe four terminal pins on the upper section of thethermostat back with the matching connector onthe subbase. Insert these, then gently pivot thethermostat body down to connect the nine pinconnectors on the lower portion of the thermo-stat back. Gently push until the snap connectorsengage. DO NOT FORCE OR PRY THE THER-MOSTAT as this may damage the unit.

Before you begin programming your thermo-stat, you should be familiar with its features andwith the display and the location and operationof the thermostat buttons. The information inthis section will help you become familiar withyour new thermostat so that you can easilyprogram it.

Your thermostat consists of two parts: the ther-mostat body and the subbase .

Use SYSTEMSWITCH to turn thermostat to OFF

mode before removing or attaching thethermostat body. Equipment damageand/or personal injury could occur.

CAUTION!

Page 6: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

6

PARTS OF THE THERMOSTAT

The Back of The Thermostat Body

Turn the thermostat body over. On the back arethe 9 volt Energizer® alkaline battery and theoption switches.

1. The 9 volt Energizer® alkaline battery pro-vides power to the thermostat when the24VAC power is interrupted (for example,when you remove the thermostat from thewall for programming). A fresh battery willmaintain the stored program for approxi-mately a week. If power loss is long enoughfor the program to be lost, the thermostat willautomatically return to the factory pro-grammed temperatures (64°F heating and82°F cooling) when power is restored. You

BACK OF THERMOSTAT BODY

Option switches 9-pin connector

4-pin connector Battery

W18

must reprogram the thermostat if this hap-pens.If the word BATTERY is flashing in thedisplay window, the battery is low and shouldbe replaced with a fresh 9 volt Energizer®

Page 7: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

7

alkaline battery. The battery will providepower for all functions except the displaylight, which works only on 24VAC power.

Use SYSTEMSWITCH to turn thermostat to OFF

mode before removing thermostat fromthe wall to replace the battery.

2. You may adjust the option switches forenergy management recovery and total key-pad lockout (see OPERATING FEA-TURES).

CAUTION!

Other than and , the buttons arelocated behind the thermostat door. To open thedoor, use your fingernail in the indentation at thetop center of the door. Pull the door out, thenswing the door down on its hinges.

Following are brief descriptions of the displayand the thermostat buttons.

Page 8: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

8

FAN AUTO is displayed during automaticfan operation (when the blower cycles withthe heating or cooling system). PRG FAN isdisplayed when the fan has been pro-grammed to run continuously during theoccupied program period.The word BATTERY flashes on the displaywhen the 9 volt alkaline battery power isweak and should be replaced.

The Display

Continuously displays system mode (HEAT,EMER, OFF, COOL, AUTO, HLD). Duringprogramming, the day of the week and theperiod (occupied or unoccupied) are dis-played (MO O, TU O, WE U, etc.).Alternately displays room temperature (Fdenotes degrees Fahrenheit and C denotesdegrees Celsius) and time of day (A de-notes AM time and P denotes PM time).

During programming, when VIEWTEMP is pressed,

the heating or cooling mode and periodcurrently being programmed are displayed(HEAT O, COOL U, etc.)Displays the setpoint temperature (this dis-play is blank in the AUTO mode).

1

2

4

5

3

Page 9: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

9

SYSTEMSWITCH

FANSWITCH

HEAT-EMER-OFF-COOL-AUTO

ON-AUTO

TIMEFWD

TIMEBACK

SETCLOCK

ADVDAY

VIEWPRGM

VIEWTEMP

HOLDCOPY

RUNPRGM

SEVEN DAY DIGITAL COMFORT-SET IIW H I T E - R O D G E R S

1 2 3

4 5

BATTERY

PRG FAN

2

3

4

EMER. PUMP

MALF. AUX.

FAN AUTOPRG FAN

Page 10: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

10

Used with and to select setpointtemperatures.Used to manually override programming tohold at a selected temperature (when HOLDis displayed). Also used to copy one day’sprogramming to another day (when COPYis displayed).Used to start program operation after pro-gramming. Also used to return thermostat toprogram operation after being in HOLDmode.(Red arrow) Raises temperature setting(99°F or 37°C maximum).(Blue arrow) Lowers temperature setting(40°F or 4°C minimum).EMER light indicates that the system is inthe emergency mode (the heat pump com-pressor is off and the auxiliary heat systemis maintaining the setpoint temperature).

The Thermostat Buttons

Sets the system mode (HEATing, OFF,COOLing, or AUTOmatic changeover).Selects fan operation (see #4, above).Runs display forward or backward throughtime, day, or anticipation settings duringprogramming.

Used with TIMEFWD and TIME

BACK to set current time

and day of the week.Used during programming to set the day ofthe week to be programmed.Used to initiate or review programming (pro-gram viewing automatically begins with

Monday’s program; use ADVDAY button to view

programming for following days).

6

7

8

9

10

11

17

15

14

13

16

12

Page 11: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

11

that the heat pump compressor is function-ing — a flashing PUMP light indicates thatthe compressor is locked out. AUX lightindicates that the auxiliary system is oper-ating.

MALF light indicates a heat pump systemmalfunction (refer to heat pumpmanufacturer's operating manual). A con-tinuous (non-flashing) PUMP light indicates

SYSTEMSWITCH

FANSWITCH

HEAT-EMER-OFF-COOL-AUTO

ON-AUTO

TIMEFWD

TIMEBACK

SETCLOCK

ADVDAY

VIEWPRGM

VIEWTEMP

HOLDCOPY

RUNPRGM

SEVEN DAY DIGITAL COMFORT-SET IIW H I T E - R O D G E R S

FAN AUTO

9 10 11 12 13 14

15 16

8

6

7

17

EMER. PUMP

MALF. AUX.

Page 12: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

12

OPERATING FEATURES

Now that you are familiar with the thermostatdisplay and buttons, read the following informa-tion to learn about the many features of thethermostat.

• COMPUTED ENERGY MANAGEMENTRECOVERY (EMR) — The thermostat’smicrocomputer automatically calculates thetime it will take to change the temperature tothe next program setting. Then the thermo-stat will activate the heating or cooling sys-tem to change the temperature so that thedesired temperature is reached at the be-ginning of the next program period. As anexample of this feature, assume that youhave programmed your thermostat to pro-vide an overnight heating temperature of

62°F, and that during the next programperiod, beginning at 6:00 AM, you haveprogrammed a temperature of 70°F. Thethermostat will automatically activate theheating system at about 5:00 AM, so thatthe programmed 70°F temperature isreached by about 6:00 AM.This feature is enabled by option switch #3.To enable the EMR function, you mustmove option switch #3 (located on the backof the thermostat body) to the ON position.

To do this, press SYSTEMSWITCH until OFF is dis-

played. Remove the thermostat body fromthe wall, turn it over, and check the positionof option switch #3. If the switch is ON (up),simply put the thermostat back on the wall

and press SYSTEMSWITCH until the desired operat-

ing mode is displayed. If the switch is OFF

Page 13: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

13

screwdriver to move option switch #3 to theOFF (down) position. Put the thermostat

back on the wall and press SYSTEMSWITCH until the

desired operating mode is displayed.• AUTOMATIC CHANGEOVER — You can

set the thermostat to automatically switchthe system from heating to cooling asneeded. To set the thermostat for automaticchangeover after programming, press

SYSTEMSWITCH to set the thermostat to AUTO (the

setpoint temperature display is blank in theAUTO mode). The system will now auto-matically switch between heating and cool-ing, depending on the actual room tempera-ture.

In the AUTO mode, the thermostat will notallow the temperature separation between

(down), use a pencil or small screwdriver tomove the switch to the ON position (seefigure below). Put the thermostat back on

the wall and press SYSTEMSWITCH until the desired

operating mode is displayed.

EMR (ON)

Switch #1 set at installation (DO NOT CHANGE)Switch #2 set at installation (DO NOT CHANGE)Switch #3 ONSwitch #4 (see TOTAL KEYPAD LOCKOUT )

To disable EMR, press SYSTEMSWITCH until OFF

is displayed. Remove the thermostat bodyfrom the wall and use a pencil or small

ON

1 2 3 4

Page 14: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

14

797877767574

COOLING TEMPERATURES

HEATING TEMPERATURES

DEAD BAND

the highest heat setting and the lowest coolsetting to be less than 1°F. For example, ifthe highest heat setting is 76°F, the lowestcool setting cannot be below 77°F (seediagram below).

• TWO HOUR TEMPERATURE OVER-RIDE — Press or until thedisplay shows the temperature you want.The thermostat will override current pro-gramming and keep the room temperatureat the selected temperature for two hours.After two hours, the thermostat will auto-matically revert to the program.

We do not recommend using the temperatureoverride feature when the thermostat is in theAUTO mode. If you press or in theAUTO mode, the thermostat will revert to themode (heat or cool) in which it last cycled and willprevent automatic switching for two hours. If youdo press or in the AUTO mode, you

may press RUNPRGM to return to programmed opera-

tion in the AUTO mode.

• HOLD TEMPERATURE — The thermostatcan hold any temperature within its rangefor an indefinite period, without reverting to

the program. Press HOLDCOPY . HLD will be dis-

played. Then choose the desired hold tem-perature by pressing or . The

NOTE

Page 15: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

15

thermostat will hold the room temperature

at the selected setting until you press RUNPRGM

to start program operation again. This fea-ture is ideal for energy conservation whenthe building is unoccupied for an extendedperiod of time.

• °F/°C CONVERTIBILITY — Press TIMEFWD and

TIMEBACK at the same time until the temperature

display is in °C (Celsius). To display °F,repeat the process.

• ADJUSTABLE HEATING AND COOLINGCYCLE TIMES (ANTICIPATION) — If theheating/cooling system is turning on and offtoo often (short cycles) or not often enough(long cycles), you may want to adjust theanticipation setting.

A cooling anticipation setting of lessthan 10 may cause decreased compres-sor life.

To adjust heat anticipation, press SETCLOCK and

ADVDAY at the same time. The display will show

HEAT 18 (this is the factory preprogrammedheating anticipation setting). You may se-lect any anticipation setting from 4 to 40(note that for add-on heat pump sys-tems, a minimum anticipation setting of10 is recommended ). Whenever adjustinganticipation, increase or decrease the dis-played number by only one or two digits,then let the system run for a while to see ifthe adjustment is sufficient. If the heat cycles

CAUTION!

Page 16: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

16

are too short, press TIMEFWD to increase the

cycle time. If the heat cycles are too long,

press TIMEBACK to decrease the cycle time. To

set cooling anticipation, press SETCLOCK and

ADVDAY at the same time again. The display will

show COOL 14 (factory preprogrammed

cooling anticipation). Use the TIMEFWD and TIME

BACK

buttons to adjust anticipation. Press RUNPRGM to

return to your program.• LOW BATTERY INDICATOR — The word

BATTERY will flash on the display if the 9volt alkaline battery is low and should bereplaced.

• AUDIO PROMPTING — Each time youpress a button, the thermostat will beep (thisfeature works only when the thermostat isattached to the wall and 24VAC power ispresent to the thermostat).

• BACKLIT DISPLAY — When you pressany button on the thermostat, the display islit for approximately eight seconds (this fea-ture works only when the thermostat isattached to the wall and 24VAC power ispresent to the thermostat).

• SYSTEM INDICATOR LIGHTS — The fourlights on the upper right part of the thermo-stat indicate system operation (see PARTSOF THE THERMOSTAT).

• COMPRESSOR SHORT CYCLE PROTEC-TION — To protect your compressor frompotential damage due to rapid cycling, thisthermostat has a built-in delay of 5 minutes

Page 17: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

17

between heat pump heating and coolingcycles. The following may cause a timedelay in COOL:

a) Return of power after a power outage.

b) Pressing SYSTEMSWITCH to change operating

modes.c) Pressing or , creating a call

for HEAT or COOL too soon after aprevious call.

• TOTAL KEYPAD LOCKOUT — When op-tion switch #4 is in the total keypad lockoutposition (ON), programs cannot be alteredand all buttons are disabled.

NOTE

ON

1 2 3 4

Programming should be completed and bat-tery should be installed before changing op-tion switch #4.

TOTAL KEYPAD LOCKOUT (ON)

Switch #1 set at installation (DO NOT CHANGE)Switch #2 set at installation (DO NOT CHANGE)Switch #3 (see EMR)Switch #4 ON

To enable total keypad lockout, pressSYSTEM

SWITCH until OFF is displayed and remove

the thermostat body from the wall. Press

Page 18: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

18

SYSTEMSWITCH until the desired operating mode

is displayed. Turn the thermostat bodyover. Use a pencil or small screwdriver tomove option switch #4 to ON (see figure onprevious page). Replace the thermostat bodyon the wall. After moving switch #4 to the

ON position, you will not be able to makeany changes to thermostat programmingor operation (all buttons will be disabled).To disable total keypad lockout, move op-tion switch #4 to OFF.

Page 19: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

19

Now you are ready to program your thermostat.This section will help you plan your thermostat'sprogram to meet your needs.

For maximum comfort and efficiency, keep thefollowing guidelines in mind when planning yourprogram.

• When heating (cooling) your building, pro-gram the temperatures to be cooler (warmer)when the building is vacant or during peri-ods of low activity.

• During early morning hours, the need forcooling is usually minimal.

PLANNING FOR YOUR NEEDS

First, answer the following questions to help youdecide what your needs are.

1a. What time does the first person arrive at thebuilding in the morning?

b. What temperature should the building be atthis time? (heating? cooling?)

2a. What time does the building become va-cant?

b. What temperature should the building be atthis time?

PROGRAMMING YOUR THERMOSTAT

Page 20: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

20

Now look at the factory preprogrammed timesand temperatures shown below. If this program

will suit your needs, simply press RUNPRGM to begin

running the factory preset program.

If you want to change the preprogrammed timesand temperatures, determine the heating andcooling times and temperatures you want touse. Use the following table to plan your pro-

gram time periods and temperatures. You mayalso want to look at the sample program table toget an idea of how the thermostat can be pro-grammed. You will select two heating tempera-tures (HEAT O for occupied temperature andHEAT U for unoccupied temperature) and twocooling temperatures (COOL O and COOL U).

To operate properly in the AUTO mode, thehighest heat temperature cannot be the sameas or higher than the lowest cool temperature (orvice versa); see diagram below.

Heating Program for ALL days of the Week:

PERIOD TIME TEMPOccupied (O)

Unoccupied (U)8:00 AM5:00 PM

7064

FANPRG

AUTO

DAMPEROpen

Closed

FACTORY PREPROGRAMMING

Cooling Program for ALL days of the Week:

PERIOD TIME TEMPOccupied (O)

Unoccupied (U)8:00 AM5:00 PM

7882

FANPRG

AUTO

DAMPEROpen

Closed

NOTE

797877767574

COOLING TEMPERATURES

HEATING TEMPERATURES

DEAD BAND

Page 21: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

21

Heating ProgramOccupied

PeriodStart Time

Monday

Tuesday

Wednesday

Thursday

Friday

Saturday

Sunday

Heating/Cooling Schedule Plan

OccupiedHeatingTemp.

UnoccupiedPeriod

Start Time

UnoccupiedHeatingTemp.

OccupiedPeriod

Start Time

OccupiedCoolingTemp.

UnoccupiedPeriod

Start Time

UnoccupiedCoolingTemp.

Cooling Program

NOTE: Fan and damper operation are linked to occupied or unoccupied temperature settings, not time periods. If you program an unoccupied temperature during an occupied time period, the fan will operate in the AUTO mode only and the damper will NOT open. We suggest programming occupied temperatures only during occupied time periods, and unoccupied temperatures during unoccupied time periods.

Page 22: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

22

Heating ProgramOccupied

PeriodStart Time

Monday

Tuesday

Wednesday

Thursday

Friday

Saturday

Sunday

SAMPLEHeating/Cooling Schedule Plan

OccupiedHeatingTemp.

UnoccupiedPeriod

Start Time

UnoccupiedHeatingTemp.

OccupiedPeriod

Start Time

OccupiedCoolingTemp.

UnoccupiedPeriod

Start Time

UnoccupiedCoolingTemp.

Cooling Program

NOTE: In the above sample program, the fan will be programmed to run continuously (PRG FAN) during periods with occupied temperatures, and will be programmed for automatic cycling (FAN AUTO) during periods with unoccupied temperatures. In your programming, you may choose automatic fan operation (FAN AUTO) during both occupied and unoccupied periods (remember that fan and damper operation are linked to temperature, not time periods).

Joe’s RestaurantOpen: Mon-Sat 10:00 AM to 9:30 PM Sun 12:00PM to 6:00 PM

9:30 AM

9:30 AM

9:30 AM

9:30 AM

9:30 AM

9:30 AM

11:30 AM

73°F

73°F

73°F

73°F

73°F

73°F

73°F

10:00 PM

10:00 PM

10:00 PM

10:00 PM

10:00 PM

10:00 PM

6:30 PM

62°F

62°F

62°F

62°F

62°F

62°F

62°F

9:30 AM

9:30 AM

9:30 AM

9:30 AM

9:30 AM

9:30 AM

11:30 AM

74°F

74°F

74°F

74°F

74°F

74°F

74°F

10:00 PM

10:00 PM

10:00 PM

10:00 PM

10:00 PM

10:00 PM

6:30 PM

79°F

79°F

79°F

79°F

79°F

79°F

79°F

Page 23: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

23

ENTERING YOUR PROGRAM

Follow these steps to enter the heating/coolingprogram you have selected.

We recommend that you remove the thermostatfrom the wall for programming (especially forentering cooling programming). A fresh 9 voltEnergizer® alkaline battery must be installed toperform off-wall programming. BE SURE SYS-TEM SWITCH IS SET TO OFF POSITION BE-FORE REATTACHING THERMOSTAT TOSUBBASE!

You cannot program the thermostat with theSYSTEM SWITCH in the AUTO position.

NOTE

Set Current Time and Day

1. Press SETCLOCK once. The display will show

minutes only.

EXAMPLE:

2. Press and hold either TIMEFWD or TIME

BACK until you

reach the correct minutes.

3. Press SETCLOCK once. The display window will

show the hour only.

EXAMPLE:

4. Press and hold either TIMEFWD or TIME

BACK until you

reach the correct hour and AM/PM designa-tion (AM begins at midnight; PM begins atnoon).

Page 24: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

24

5. Press SETCLOCK once. The display will show the

day of the week as an abbreviation (MO forMonday, TU for Tuesday, etc.).

6. Press and hold either TIMEFWD or TIME

BACK until you

reach the current day of the week.

7. Press RUNPRGM once. The display will show the

correct time and room temperature alter-nately.

Program Heating/Cooling Temperatures

During programming, if you don’t press anybuttons for 5 minutes, the thermostat will enterthe HOLD mode and will maintain a constanttemperature. The display will revert to the alter-nating time/temperature display. To resume pro-

gramming after this happens, press VIEWPRGM until

you are at the point where you stopped program-ming. Then you may continue to enter yourprogram normally. If you want to stop program-

ming at any time, simply press RUNPRGM to resume

program operation.

1. Press SYSTEMSWITCH until HEAT is displayed.

2. Press VIEWTEMP once. The display will continue

to show HEAT. Beside HEAT is the letter O,representing the occupied heating tempera-ture (HEAT O). At the right of the display isthe currently programmed HEAT O setting.

3. Press either or to change thetemperature to your selected HEAT O set-ting.

Page 25: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

25

4. Press VIEWTEMP once. The letter O will change to

the letter U, representing the unoccupiedheating temperature (HEAT U).

5. Press either or to change thetemperature to your selected HEAT U set-ting.

6. Press RUNPRGM .

7. Press SYSTEMSWITCH until COOL is displayed.

8. Press VIEWTEMP once. The display will show

COOL and O, representing the first pro-grammed cooling temperature (COOL O).

9. Press either or to change thetemperature to your selected COOL O set-ting.

10. Press VIEWTEMP once. Press or to

set your selected COOL U setting.

11. Press RUNPRGM .

Enter Heating Program

1. Press SYSTEMSWITCH until HEAT is displayed.

2. Press VIEWPRGM once. MO, the abbreviation for

Monday, and the letter O, representing theoccupied heating period, will appear in thedisplay. Also displayed are the currentlyprogrammed start time for the occupiedheating period and the currently programmedHEAT O temperature.

EXAMPLE: PRG FAN

Page 26: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

26

This display window shows that for Monday’soccupied heating period, the start time is8:00 AM, 70° is the programmed tempera-ture, and the fan is set to PRG FAN (continu-ous fan operation); this example reflectsfactory preprogramming, where 70° is theHEAT O temperature.

3. To change the displayed start time to yourselected start time for Monday’s occupied

heating period, press TIMEFWD or TIME

BACK until your

selected time appears. The time will changein 15 minute increments.

4. If the temperature displayed is not the heat-ing temperature you want for Monday’s oc-cupied period, press or (if youcontinue to press or , the display

will alternate between the HEAT O andHEAT U temperatures you previously se-lected).

The fan and damper operation are linked to theoccupied or unoccupied temperature selec-tions, not to the occupied or unoccupied timeperiods. The programmable fan feature worksonly during periods with occupied temperaturesettings, and the damper will only operate dur-ing periods with occupied temperature settings.Therefore, we suggest that you program occu-pied temperatures during occupied periods andunoccupied temperatures during unoccupiedperiods.

NOTE

Page 27: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

27

5. If you want the fan to run continuouslyduring Monday’s occupied period, press

FANSWITCH until PRG FAN is displayed (re-

member, this feature only works if you haveprogrammed an occupied temperature forthis period).

6. After selecting the desired heating tempera-ture for Monday’s occupied period, press

VIEWPRGM . The currently programmed start time

and heating temperature for Monday’s un-occupied heating period will be displayed.

7. Repeat steps 3 and 4 to select the start timeand heating temperature for Monday’s un-occupied heating period.

The thermostat has a built-in COPY feature.This feature automatically copies the heat-ing and cooling programs you select forMonday into Tuesday through Sunday’s pro-grams. If you want to have the same program-ming every day, after you program Monday’s

schedule, you simply press RUNPRGM to start the

thermostat’s programmed operation. Every daywill then use the same program you set for

Monday. You may also choose to use the HOLDCOPY

button to copy any day’s heating and coolingprogram into any other day’s program (seeUSING THE HOLD/COPY BUTTON ).

NOTE

Page 28: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

28

8. To enter Tuesday’s through Sunday’s heat-

ing programs, use the HOLDCOPY button (see

USING THE HOLD/COPY BUTTON ), or

press ADVDAY until the correct day’s abbrevia-

tion appears in the display. Repeat theabove steps to program each day’s heatingperiods and temperatures.

9. When you have completed programmingyour heating periods and temperatures,

press RUNPRGM to begin program operation.

Enter Cooling Program

If outside temperature is below 50 °F, werecommend that you remove the thermo-stat from the wall before proceeding with

the following steps to program coolingtemperatures. Personal injury or prop-erty damage may occur due to air condi-tioner operation during cold weather. Afresh 9 volt Energizer ® alkaline batterymust be installed to perform off-wall pro-gramming. Programming away from thewall should prevent accidental compres-sor operation. BE SURE SYSTEMSWITCH IS SET TO OFF POSITION BE-FORE REATTACHING THE THERMO-STAT TO THE SUBBASE!

1. Press SYSTEMSWITCH until COOL is displayed.

2. Press VIEWPRGM once. MO, the abbreviation for

Monday, and the letter O, representing theoccupied cooling period, will appear in the

CAUTION!

Page 29: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

29

display. Also displayed are the currentlyprogrammed start time for the occupiedcooling period and the currently programmedCOOL O temperature.

3. To change the displayed start time to yourselected start time for Monday’s occupied

cooling period, press TIMEFWD or TIME

BACK until your

selected time appears. The time will changein 15 minute increments.

4. If the temperature displayed is not the cool-ing temperature you want for Monday’s oc-cupied period, press or (if youcontinue to press or , the displaywill alternate between the COOL O andCOOL U temperatures you previously se-lected).

The fan and damper operation are linked to theoccupied or unoccupied temperature selec-tions, not to the occupied or unoccupied timeperiods. The programmable fan feature worksonly during periods with occupied temperaturesettings, and the damper will only operate dur-ing periods with occupied temperature settings.Therefore, we suggest that you program occu-pied temperatures during occupied periods andunoccupied temperatures during unoccupiedperiods.

5. If you want the fan to run continuouslyduring Monday’s occupied period, press

FANSWITCH until PRG FAN is displayed (re-

member, this feature only works if you have

NOTE

Page 30: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

30

programmed an occupied temperature forthis period).

6. After selecting the desired cooling tempera-ture for Monday’s occupied period, press

VIEWPRGM . The currently programmed start time

and cooling temperature for Monday’s un-occupied cooling period will be displayed.

7. Repeat steps 3 and 4 to select the start timeand cooling temperature for Monday’s un-occupied cooling period.

The thermostat has a built-in COPY feature.This feature automatically copies the heat-ing and cooling programs you select forMonday into Tuesday through Sunday’s pro-grams. If you want to have the same program-ming every day, after you program Monday’s

schedule, you simply press RUNPRGM to start the

thermostat’s programmed operation. Every daywill then use the same program you set for

Monday. You may also choose to use the HOLDCOPY

button to copy any day’s heating and coolingprogram into any other day’s program (seeUSING THE HOLD/COPY BUTTON ).

8. To enter Tuesday’s through Sunday’s cool-

ing programs, use the HOLDCOPY button (see

USING THE HOLD/COPY BUTTON ), or

press ADVDAY until the correct day’s abbrevia-

tion appears in the display. Repeat theabove steps to program each day’s coolingperiods and temperatures.

NOTE

Page 31: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

31

9. When you have completed programmingyour cooling periods and temperatures,

press RUNPRGM to begin program operation.

Using The HOLD/COPY Button

You can copy the entire heating/cooling pro-gram into any or all other days’ programs. How-ever, you must perform each copy functionseparately. Each time you begin a COPY opera-tion, you must start with the day’s program youwish to copy FROM. A COPY operation is not

complete until HOLDCOPY has been pressed TWICE.

For most efficient programming, you shouldenter both the heating and cooling programs forthe day you wish to copy FROM before using theCOPY function, since the COPY function copiesthe entire day’s programming to other days.

1. Press VIEWPRGM .

2. Press ADVDAY until the day you want to copy

FROM is displayed. If you have not com-pleted programming for this day, do sobefore proceeding.

3. Press HOLDCOPY once. C (standing for COPY)

will appear on the display. A number from 1to 7 will also appear, representing the dayyou have selected to copy (Monday is 1,Tuesday is 2, Wednesday is 3, etc.). Forexample, if in step 2 you selected to copyWednesday’s program, when you press

HOLDCOPY , C 3 will appear in the display (as

shown below).

EXAMPLE:

Page 32: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

32

4. Press ADVDAY to select the day you want to

copy the program TO.

5. Press HOLDCOPY . C will disappear from the dis-

play, and the display will show the copiedheating/cooling time and temperature forthe day you copied TO.

6. Repeat the above steps to copy any day’sprogramming into any other day’s program.

7. Press RUNPRGM to begin program operation.

CHECK YOUR PROGRAMMING

Follow these steps to check your thermostatprogramming one final time before beginningthermostat operation.

1. Press SYSTEMSWITCH until HEAT is displayed.

2. Press and hold VIEWPRGM to view the heating

times and temperatures for Monday.

3. Press ADVDAY once to advance to Tuesday.

4. Press and hold VIEWPRGM to view heating/cooling

periods and heating temperatures for Tues-day.

5. Repeat steps 3 and 4 to review all remain-ing days’ heating programming. If you findan error in any day’s programming, go backto the programming instructions to correctthe error.

6. Press RUNPRGM .

7. Press SYSTEMSWITCH until COOL is displayed.

Page 33: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

33

8. Repeat steps 2 through 5 to check coolingtimes and temperatures.

9. Press RUNPRGM to begin program operation.

YOUR THERMOSTAT IS NOW COMPLETELYPROGRAMMED AND READY TO AUTOMATI-CALLY PROVIDE MAXIMUM COMFORT ANDEFFICIENCY!

Press SYSTEMSWITCH until OFF is displayed. Reattach

thermostat to subbase. Then press SYSTEMSWITCH to

select the operation mode you want (HEAT,COOL, AUTO).

When you have completed programming, youmay set option switch #4 (see TOTAL KEYPADLOCKOUT in the OPERATING FEATURESsection).

Page 34: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

34

1. How can I permanently change a part ofmy program?

Press VIEWPRGM and ADV

DAY until you reach the

time/temperature schedule you want. Then

press or and TIMEFWD and TIME

BACK to

change the program. See PROGRAMMINGYOUR THERMOSTAT.

2. How can I finish my programming if thedisplay has already changed to time/temperature?During programming, if no buttons arepressed for five minutes, the thermostat willenter the HOLD mode and maintain a con-stant temperature. The display will change

to the time/temperature mode. To resume

programming, press VIEWPRGM until you return to

the point where you stopped programming.Then you may continue to program thethermostat normally. If you want to stop

programming at this point, press RUNPRGM to

start the normal program function. See PRO-GRAMMING YOUR THERMOSTAT .

3. What happens if the electricity goes offor is manually shut off?If you have not installed a 9 volt alkalinebattery, the display will go blank and theprogram will be lost in five seconds. Whenelectricity is restored, the thermostat willmaintain a heating temperature of 64°F and

QUESTIONS AND ANSWERS

Page 35: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

35

a cooling temperature of 82°F until youreenter your program. Setpoint tempera-ture will not be displayed.

If a fresh 9 volt Energizer® alkaline battery isinstalled, the program will be maintained forabout one week with no 24VAC powerpresent to the thermostat. See OPERAT-ING YOUR THERMOSTAT.

4. Why can’t I program the thermostat inthe AUTO mode?The thermostat can only be programmed inthe HEAT and COOL modes. See PRO-GRAMMING YOUR THERMOSTAT .

5. What can cause the thermostat displayto freeze or go blank?A completely blank display may indicatethat power has been lost to the thermostatand the backup battery is also dead. How-

ever, if there is power to the thermostat andthe display is blank or frozen, static dis-charge is probably the cause.

During periods of low humidity (especiallyduring cold weather), you may feel or see aspark discharge when you touch the ther-mostat. This may cause the program to belost or the thermostat to display incorrectly.To correct this, remove the thermostat fromthe wall and remove the battery for at leasttwo minutes. After reinstalling the battery,the thermostat will revert to the factory pre-set program until you reprogram the ther-mostat. If you don’t want to reprogram the

thermostat immediately, press SYSTEMSWITCH un-

til OFF is displayed and replace the thermo-

stat on the wall. Then press RUNPRGM to begin

the factory preset program.

Page 36: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

36

To prevent further static discharge prob-lems, touch another object to release staticbuild-up before touching the thermostat.See OPERATING YOUR THERMOSTAT .

6. Why won’t the setpoint temperature goto the temperature I want?In the AUTO mode, the highest heatingsetpoint temperature you select cannot bethe same as or higher than the lowest cool-ing setpoint temperature you select (forexample, if 70°F is your lowest selectedcooling temperature, you cannot select aheating temperature any higher than 69°F).If such a conflict exists, set the lowest cool-ing temperature higher in order to set theheating temperature higher. To set a lowercooling temperature, you must select a lowerheating temperature. See PROGRAMMINGYOUR THERMOSTAT.

7. Why doesn’t the display light come onwhen I press a button? Why don’t I heara beep when I press a button?The display light and audio prompting (beep)only work when the thermostat is on the walland 24VAC power is present to the thermo-stat. See OPERATING YOUR THERMO-STAT.

8. The display is flashing BATTERY. Whatdoes this mean?The 9 volt battery installed in the thermostatis low and should be replaced with a fresh 9volt Energizer® alkaline battery. See OPER-ATING YOUR THERMOSTAT .

9. Why won’t the system turn on, eventhough the thermostat display is func-tioning normally?Either the compressor lockout feature is inoperation or the thermostat is not currently

Page 37: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

37

calling for heat or cool. If the compressorlockout is active, the PUMP LED will flash.Wait about 5 minutes for the compressorlockout to expire. If the system is still notrunning, read the cautionary statement be-low. Then, if conditions permit , use or to move the temperature above orbelow the setpoint temperature. See OP-ERATING YOUR THERMOSTAT .

If the outside temperature is below 50 °F,DO NOT use the button to move thetemperature below the setpoint tempera-ture. Property damage may result fromcompressor operation during coldweather.

10. Why doesn’t the temperature change atthe time I programmed?There are a number of causes for this situ-ation. The following are primary reasons.

• The EMR function is operating. The EMRfunction will automatically turn on thesystem early enough to bring the tem-perature to the selected level by thebeginning of the next program period.See OPERATING YOUR THERMO-STAT.

• You have programmed the incorrect dayor time. Check your programming (besure that the times you programmed arecorrect AM or PM times). See PRO-GRAMMING YOUR THERMOSTAT .

• The thermostat is in the HOLD mode.

Press RUNPRGM to start program operation.

CAUTION!

Page 38: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

38

See OPERATING YOUR THERMO-STAT.

• If the PUMP LED is flashing, the com-pressor lockout feature is operating; waitabout 5 minutes for system to beginrunning. See OPERATING YOURTHERMOSTAT.

11. Why does the blower fan keep runningafter the system has turned off?The blower delay feature is operating. Thisenergy saving feature continues to blowconditioned air through the ducts after thesystem has turned off, rather than letting theair dissipate.

12. Why is the system turning on and off sofrequently (seldom)?The anticipation setting is too low (high). To

change anticipation settings, see OPER-ATING YOUR THERMOSTAT .

13. Between heating and cooling seasons, Iwant to turn my system off. Can I do thiswithout affecting my thermostat pro-gramming?Any time you wish to turn your system off,

press SYSTEMSWITCH until the display shows OFF.

This will not affect your thermostat's pro-gramming in any way. To turn the system

back on, press SYSTEMSWITCH until HEAT, COOL,

etc. is displayed. The system will automati-cally begin operating according to the cur-rent thermostat program, unless the ther-

Page 39: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

39

mostat is in the HOLD mode. See OPER-ATING YOUR THERMOSTAT .

14. I live in an area where daylight savingstime is observed. How do I change thethermostat clock twice a year withoutaffecting thermostat programming?To change your clock, follow the instruc-tions for setting current time and day. SeeENTERING YOUR PROGRAM. Thermo-stat programming is not affected when youchange the clock.

15. Do I have to reprogram my thermostatafter I change the battery?When the thermostat is on the wall and thesystem has power, the thermostat is beingpowered by a 24VAC source. If power islost, or if the thermostat is removed from thewall, the program will be retained for ap-proximately one minute if there is no bat-

tery installed or if the installed battery isdead. If you are changing the battery afterseeing a flashing BATTERY on the display,the installed battery may be dead. If youremove the old battery and install a freshone within one minute, you may not loseyour thermostat programming. After install-ing a new battery, follow the procedures inCHECK YOUR PROGRAMMING to deter-mine whether your programming was main-tained. If the thermostat maintains program-

ming, press SYSTEMSWITCH until OFF is displayed,

put the thermostat back on the wall, pressSYSTEM

SWITCH to select the operating mode you

want, then press RUNPRGM to start program

operation. If programming is lost, you mustreprogram the thermostat. See PROGRAM-MING YOUR THERMOSTAT.

Page 40: OPERATION GUIDE 1F94-80 - Emerson Climate€¦ · OPERATION GUIDE 7 Day Multi-stage/Heat Pump Electronic Digital Thermostat 1F94-80 WHITE-RODGERS Operator: Save this booklet for future

R

Part No. 37-5186A

9329

If you need further information on programming or operation, you may writeto our Technical Service Department at the address shown below.

WHITE-RODGERS DIVISIONEMERSON ELECTRIC CO.9797 REAVIS ROADST. LOUIS, MISSOURI 63123-5398