Operating Manual

DLS 410A

North American ADSL2++ Wireline Simulator

Revision 4 October 2004

Page 2: Operating Manual DLS 410A - Spirent
Page 3: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Table of Contents Page i7104000548-10/04-4

Table of Contents

1. INTRODUCTION ............................................................................................. 1-11.1 About Spirent’s Involvement in Wireline Simulation ....................................... 1-11.2 About DLS 410A ADSL2++ Wireline Simulators ............................................ 1-1

1.2.1 Loop Topologies Available on the DLS 410A ............................................. 1-31.3 About the Test Setup .......................................................................................... 1-51.4 About this Manual ............................................................................................. 1-6

1.4.1 About Related Documentation and Products .............................................. 1-7

2. GETTING STARTED ...................................................................................... 2-12.1 Receiving and Unpacking the Unit .................................................................... 2-12.2 Setup Overview ................................................................................................. 2-12.3 Cabling Requirements ....................................................................................... 2-22.4 Front Panel Components and Connections ........................................................ 2-2

2.4.1 Reading Remote and Power Status ............................................................. 2-32.4.2 Connecting the DLS 411A to the DLS 412A ............................................... 2-32.4.3 Injecting Noise in the System ...................................................................... 2-32.4.4 Connecting to Analog Devices with CF Connectors .................................. 2-42.4.5 Connecting to Analog Devices with RJ-45 Connectors (Adapters) ............ 2-4

2.5 Back Panel Components and Connections ........................................................ 2-52.5.6 Connecting to Power ................................................................................... 2-52.5.7 Connecting to a Windows Computer (for Remote Control) ........................ 2-6

2.5.7.1 Connecting the Computer via the Serial Port (RS-232) ................................. 2-62.5.7.2 Connecting the Computer via the IEEE 488 Port (GPIB) .............................. 2-6

3. DLS 410A SOFTWARE .................................................................................. 3-13.1 About the Software ............................................................................................ 3-1

3.1.1 GPIB Settings .............................................................................................. 3-13.1.2 Computer Hardware and Software Requirements ...................................... 3-2

3.2 Installing the Software ....................................................................................... 3-23.2.3 Starting the Software ................................................................................... 3-33.2.4 Accessing the Control Window (s) .............................................................. 3-33.2.5 Accessing the Advanced Settings ................................................................ 3-9

3.3 Configuring the DLS 410A ............................................................................... 3-93.3.1 Identifying Simulator Connection ............................................................... 3-93.3.2 Software Communication with the Wireline Simulator ............................. 3-103.3.3 Configuring the Loop Length Mode .......................................................... 3-103.3.4 Selecting the Cable Model ........................................................................ 3-123.3.5 Selecting the Test Loop ............................................................................. 3-123.3.6 Selecting the Loop Simulation ................................................................... 3-123.3.7 Controlling the DLS 410A Noise Injection Ports ...................................... 3-133.3.8 Configuring the Length of the DLS 410A Line Segments ......................... 3-133.3.9 Accessing Advanced Information About the Unit ..................................... 3-143.3.10 Using The DLS Terminal Window .......................................................... 3-15

4. PERFORMING SYSTEM COMPENSATION TESTS .................... 4-14.1 Overview ............................................................................................................ 4-14.2 Required Equipment .......................................................................................... 4-14.3 Accessing the System Compensation Software ................................................. 4-1

4.3.1 HP 4395A Analyzer Settings ....................................................................... 4-24.3.2 Frequency Range Settings ........................................................................... 4-2

Page 4: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page ii Table of Contents - Spirent Communications

7104000548-10/04-4

4.4 General Procedure ............................................................................................. 4-24.5 Mean Absolute Error (MAE) and Mean Error (ME) Measurements ................ 4-44.6 Connection Accessories ..................................................................................... 4-54.7 Output and Results ............................................................................................. 4-54.8 Spectrum/Network Analyzer Settings ............................................................... 4-7

5. REMOTE CONTROL ..................................................................................... 5-15.1 IEEE 488 Interface ............................................................................................ 5-1

5.1.1 IEEE 488.1 Interface Functions Supported ................................................ 5-15.1.2 IEEE 488 Address ....................................................................................... 5-15.1.3 The Service Request (SRQ) Line ................................................................. 5-25.1.4 Message Terminators .................................................................................. 5-25.1.5 Example using the IEEE 488 Interface ....................................................... 5-3

5.2 RS-232 Serial Interface ...................................................................................... 5-35.2.1 Message Terminators .................................................................................. 5-45.2.2 Example using the RS-232 Interface ........................................................... 5-4

5.3 Command Syntax .............................................................................................. 5-55.4 DEVICE DEPENDENT COMMAND SET ...................................................... 5-6

5.4.1 System Check Commands ............................................................................ 5-65.4.1.1 :System:Error? .......................................................................................... 5-65.4.1.2 :System:SlotID? ........................................................................................ 5-75.4.1.3 :System:Calibration:date? .......................................................................... 5-75.4.1.4 :System:Calibration:expiry? ....................................................................... 5-75.4.1.5 :System:Calibration:date <date> ................................................................. 5-75.4.1.6 :System:Calibration:expiry <date> ............................................................. 5-7

5.4.2 :SETting:CHANel:State<Normal|Bypass|Disconnect> ............................. 5-75.4.3 :SETM1<String>/SETM2<String>/SETM3<String> ................................ 5-7

5.4.3.7 Steps For Using a .CSV File to Determine M1, M2 and M3 Values ................ 5-85.4.3.8 Using the DLS 410A Converter API to Determine M1, M2 and M3 Values .... 5-9

5.4.4 :SourceA:Noise <ON|OFF> (DLS 411A only) ........................................ 5-145.4.5 :SourceB:Noise <ON|OFF> (DLS 412A only) ........................................ 5-145.4.6 :System:Reset ............................................................................................ 5-14

5.5 Common Command Set ................................................................................... 5-145.6 Status Reporting ............................................................................................... 5-17

5.6.1 Status Byte Register (STB) ........................................................................ 5-185.6.2 Event Status Register (ESR) ...................................................................... 5-18

5.7 DLS 410A Synchronization ............................................................................. 5-19

6. REFERENCES ................................................................................................... 6-1

7. CUSTOMER SUPPORT ................................................................................ 7-17.1 Customer Service Contact Information ............................................................. 7-17.2 Protecting Your Investment ............................................................................... 7-1

8. WARRANTY ....................................................................................................... 8-1

9. SHIPPING THE UNIT .................................................................................... 9-1

10. SPECIFICATIONS ....................................................................................... 10-110.1 Wireline Simulator Specifications ................................................................. 10-110.2 Operating Conditions ..................................................................................... 10-2

Page 5: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Table of Contents Page iii

7104000548-10/04-4

11. SAFETY ............................................................................................................ 11-111.1 Information .................................................................................................... 11-1

11.1.1 Protective Grounding (Earthing) ............................................................ 11-111.1.2 Before Operating the Unit ....................................................................... 11-111.1.3 Power Supply Requirements ................................................................... 11-111.1.4 Fuses ....................................................................................................... 11-111.1.5 Connections to a Power Supply .............................................................. 11-111.1.6 Operating Environment ........................................................................... 11-211.1.7 Class of Equipment ................................................................................. 11-2

11.2 Instructions ..................................................................................................... 11-211.2.1 Before Operating the Unit ....................................................................... 11-211.2.2 Operating the Unit .................................................................................. 11-2

11.3 Symbols ......................................................................................................... 11-3

Page 6: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page iv Table of Contents - Spirent Communications

7104000548-10/04-4

Page 7: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 1-1

7104000548-10/04-4

1. INTRODUCTION

1.1 About Spirent’s Involvement in Wireline SimulationThank you for choosing Spirent Communications.

Spirent Communications has been in the wireline simulation business for over 15 years. Over the years, Spirent Communications has designed many new simulators both to customers' specifications and to con-form to an ever-growing range of standards.

In order to re-use the large installed base of ADSL equipment for revenue generation, local exchange carri-ers strive to achieve higher data rate and longer reach while maintaining operation with, or minimizing replacement of, existing equipment. Several potential improvements to the conventional ADSL transceiver systems have been identified in ITU-T Draft Recommendation G.992.5 (February 20, 2003) to better address higher data rates for short loops and longer reaches for high data rates. G.992.5 is also known as G.adslplus, ADSL2+, ADSL2++ or ADSL2plus. For the purposes of this manual, we will use the term ADSL2++.

The DLS 410A can simulate wireline loops based on 2 different standard cable model specifications: T1.417 (for ADSL2++ requirements) and G.996.1 (for ADSL2, WT-085 and TR-048 requirements). For a list of the loop topologies that can be simulated, please see Chapter 1.2.1 "Loop Topologies Available on the DLS 410A".

Spirent Communications developed the first ADSL2++ test solution for the North American market, con-sisting of the DLS 410A ADSL2++ Wireline Simulator and the DLS 5200AP Noise Generation System.

1.2 About DLS 410A ADSL2++ Wireline SimulatorsThe DLS 410A ADSL2++ Wireline Simulator shown in Figure 1.1 reproduces the AC and DC characteris-tics of twisted pair copper telephony cable using passive circuitry (R, L & C), which means that attenuation, complex impedance and velocity (propagation delay) of all wirelines are properly simulated.

The simulator shown in Figure 1.1 is made up of two chassis (DLS 411A + DLS 412A) that simulate all North American ADSL2plus test loops as specified in the G.992.5 ADSL2plus specification and provides two ports for external noise injection via the DLS 5200AP Noise Generation System. The DLS 410A offers an automatic relay refresh feature.

Page 8: Operating Manual DLS 410A - Spirent

DLS 411A

North American ADSL2++ Wireline Simulator

North American ADSL2++ Wireline Simulator

DLS 412A

DLS 410A Operating Manual

Page 1-2 - Spirent Communications

7104000548-10/04-4

Figure 1.1 DLS 411A and DLS 412A ADSL2++ Wireline Simulators

The DLS 410A ADSL2++ Wireline Simulator simulates a Straight Loop, a Straight Loop with Bridged Tap, ANSI 13 and CSA 4 with the capability to vary the length of each of the lines within the loops, for ADSL2++ as well as for ADSL applications. The simulation of the cable models is selectable as per ANSI T1.417 and ITU-T G.996.1, thus providing increased flexibility for testing ADSL, ADSl2 and ADSL2++ equipment. The DLS 410A has a bandwidth of DC to 4.5 MHz.

The DLS 410A ADSL2++ Wireline Simulator and the DLS 5200AP Noise Generation System are an inte-grated system designed with all required loop models and noise files to support North American ADSL2++ testing. The simulator’s front panel interfaces can be connected to up to two noise sources and/or external test devices for easy integration into a larger test system.

The DLS 410A Software configures and controls the DLS 410A ADSL2++ Wireline Simulator remotely through the IEEE 488 or RS-232 interfaces. The software runs on any WindowsTM 98/NT/2000 compatible computer. The IEEE 488 and RS-232 interfaces allow the easy integration of these wireline simulators into a larger test system. You can also control the DLS 410A ADSL2++ Wireline Simulator with scripts using SCPI commands.

Page 9: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 1-3

7104000548-10/04-4

1.2.1 Loop Topologies Available on the DLS 410A

Figure 1.2 Straight Loop Topology

Figure 1.3 Bridged Tap Loop Topology

Page 10: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 1-4 - Spirent Communications

7104000548-10/04-4

Figure 1.4 ANSI 13 Loop Topology

Figure 1.5 CSA 4 Loop Topology

Page 11: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 1-5

7104000548-10/04-4

1.3 About the Test SetupITU-T Draft Recommendation G.992.5 ADSL2plus specification was created by the ITU-T SG15 Q4 to identify ADSL2++ transceiver improvements that permit higher data rates for short loops and longer reach for high data rates.

For the North American ADSL2++ market, several contributions were made to the ITU-T. These proposals were submitted during the DC-048R2 Contributions to ITU-T SG15 Q4. These contributions proposed spe-cific metallic loops and crosstalk disturbers in order to initialize definitions of the ADSL2++ physical layer testing criteria. Their proposal is similar in concept to G.adslplus, but extends the ADSL2+ bandwidth to 4.5 MHz.

The DLS 410A provides all loop simulation requirements as presented by ITU-T Draft Recommendation G.992.5 ADSL2plus specification. Using the DLS 5200AP Noise Generation System with the DLS 410A ADSL2++ Wireline Simulator allows you to add a wide variety of noise profiles to the line, and test tele-communications transmission systems. The SMB 200/2000 provides the traffic generation /analysis.

Using this test set-up enables you to be certain that the device under test (DUT) will pass ITU-T certification testing. The DLS 410A and DLS 5200AP system is the most comprehensive and accurate test bed available for ADSL2++ applications and noises on North American wirelines. Spirent AE solution users know that this advantage translates into robust performance, earlier product delivery and greater market share. For more information on compatible Spirent Communications products, see the About Related Documentation and Products section of this chapter.

Figure 1.6 illustrates an example of a typical test setup using the DLS 410A ADSL2++ Wireline Simulator.

Page 12: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 1-6 - Spirent Communications

7104000548-10/04-4

Figure 1.6 Example Test System Setup

1.4 About this ManualYou should read Chapter 2 "GETTING STARTED" thoroughly before powering up the DLS 410A ADSL2++ Wireline Simulator. The remainder of this manual provides information about the various aspects of the wireline simulator, such as loop configurations, remote control, warranty, specifications and contact information.

We recommend you use our DLS 410A Software to configure and control the wireline simulator. However, we detail common and device specific commands sets that can be sent to the wireline simulator’s control module through the IEEE 488 or RS-232 interfaces, in Chapter 5 "REMOTE CONTROL" .

If there are any questions after reading this manual, please contact your Spirent Communications sales rep-resentative or a member of the Customer Service team. Please find contact information in Chapter 7 "CUS-TOMER SUPPORT" of this manual.

Page 13: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 1-7

7104000548-10/04-4

1.4.1 About Related Documentation and ProductsExisting customers can view and down load the following manuals from the Spirent extranet site:

http://ae.spirentcom.com/extranet.htm

• DLS 5204 Operating Manual

• DLS 5404 Operating Manual

For new customers, please contact Spirent Communications Customer Service about getting access to the site. Apply for a password at http://ae.spirentcom.com/extranet.htm.

Page 14: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 1-8 - Spirent Communications

7104000548-10/04-4

Page 15: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 2-1

7104000548--10/04-4

2. GETTING STARTED

This chapter provides basic instructions on the setup of a DLS 410A ADSL 2++ Wireline Simulator system.

2.1 Receiving and Unpacking the UnitEach DLS 410A chassis has been shipped in a reinforced shipping container. Please retain this container in case you need to ship the wireline simulator to another location or for repair. The DLS 410A system con-tains the following:

• DLS 411A (chassis 1) and DLS 412A (chassis 2)

• 1 power cord per chassis

• 2 extra fuses per chassis

• 1 RJ-45 blue unshielded twisted pair (UTP) inter-connection cable

• 1 RS–232C inter-connection cable per chassis

• 1 IEEE 488 inter-connection cable per chassis

• 1 IEEE reverser per chassis

• 1 DLS 410A Software

• 1 Operating Manual on CD

Check that you have received all the items on the list and report any discrepancies to Spirent Communica-tions. See Chapter 9 "SHIPPING THE UNIT" for information.

2.2 Setup OverviewTo test:

1) Connect the power cord to both chassis of the DLS 410A and switch the power on.2) Ensure that both of the DLS 410A chassis have different IEEE addresses.3) Connect a IEEE reverser to the IEEE 488 port on the back of both the 411A and 412A chassis.4) Connect a cable from the computer to the DLS410A. If using IEEE 488 cable, connect a second

IEEE 488 cable from DLS 411A to DLS 412A. If using serial cable to both chassis, connect the first computer serial port to the DLS 411A and the second serial port to the DLS 412A.Note: Only one DLS 410A system should be connected to the control computer at a time.

5) Connect your digital subscriber line access multiplexer (DSLAM) equipment to side A of the DLS 411A.

6) Connect side B of DLS 411A to side A of DLS 412A using the supplied blue UTP cable.7) Connect your customer premise equipment (CPE) equipment to side B of the DLS 412A.8) Start the DLS 410A Software.9) Click the Online button to connect the software to the DLS410A.10) Select the test loop and adjust the line lengths for the desired test loop.11) If using a DLS 5200AP noise generation system , connect the output of the DLS 5404 noise injec-

tion circuit to NA port (for side A noise injection) or NB port (for side B noise injection).12) If using a DLS 5200AP noise generation system, select the desired impairments.13) Begin testing.

See the following sections for detailed information.

Page 16: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 2-2 - Spirent Communications

7104000548-10/04-4

2.3 Cabling Requirements

Cabling, switches and other equipment are needed to connect the DSLAM, the loop simulator, the noise generator and the CPE. Cables should be kept as short as possible so minimum noise is coupled into the cables. Recommended cables are the CAT5 UTP. Since the length is typically short (e.g., 2 feet), this does not affect measurements.

Computer screen and power supplies radiate in ADSL 2++ frequency bands. This noise may be generated by either internal or external power supplies. When the pick up noise levels are greater than -140 dBm /Hz, they will limit the ADSL 2++ performance and influence the test results. These devices should be placed at a dis-tance from the test setup or even switched off.

Ports NA and NB wiring as well as Side A and Side B interconnection wiring should be physically separated as crosstalk can occur between cabling. Configure the cables so that they are not touching and the cable con-necting to the DSLAM and CPE are separated as much as possible (at least 6 in).

2.4 Front Panel Components and ConnectionsThe DLS 411A and DLS 412A together simulate all of the test loops as per Figure 1.2, "Straight Loop Topology". The connections on the front panel are used for connecting devices under test (DUT) and/or noise sources and, reading the power and remote status. displays the key components of the front panel.

Note: Front panel states the connectors’ input requirements of “+37dBm Max” (Referring to Section E.4.1 of G.test - A signal of +36dBm at 400Hz maybe used as a howler signal) and of “+/-200VDC Max”.

spirentcom.com

REMOTE

POWER

DLS 410 Series

+37 dBm Max+/-200 VDC Max

Side A

+37 dBm Max+/-200 VDC Max

Side B

DLS 411JJapanese ADSL+ Wireline Simulator

spirentcom.com

REMOTE

POWER

DLS 410 Series

+37 dBm Max+/-200 VDC Max

Side A

+37 dBm Max+/-200 VDC Max

Side B

DLS 412JJapanese ADSL+ Wireline Simulator

1

3

2

8

7

4

5 6

NA NB

NA NB

North American ADSL2++ Wireline Simulator

North American ADSL2++ Wireline Simulator

B

4

9

9

R

TE

A

R

TE

Figure 2.1 DLS 410A Wireline Simulator Front Panel (above/below setup)

Page 17: Operating Manual DLS 410A - Spirent

spirentcom.com

REMOTE

POWER

DLS 410 Series

+37 dBm Max+/-200 VDC Max

Side A

+37 dBm Max+/-200 VDC Max

Side B

DLS411JJapanese ADSL+ Wireline Simulator

spirentcom.com

REMOTE

POWER

DLS 410 Series

+37 dBm Max+/-200 VDC Max

Side A

+37 dBm Max+/-200 VDC Max

Side B

DLS412JJapanese ADSL+ Wireline Simulator

REMOTE

R

NA NANB NB

North American ADSL2++ Wireline Simulator

411ANorth American ADSL2++ Wireline Simulator

412A

DLS 410A Operating Manual

Spirent Communications - Page 2-3

7104000548-10/04-4

Figure 2.2 DLS 410A Wireline Simulator Front Panel (side by side setup)

DLS 411A and DLS 412A Front Panel Components

1. Side A, RJ-45 connector: used to connect a DUT (for 411A) or a second chassis (412A)2. Side A, balanced CF connector: used to connect a DUT (for 411A) or a second chassis (412A)3. NA, RJ-45 connector: used to connect a noise injector (for DLS 411A chassis)4. NB, RJ-45 connector: used to connect a noise injector (for DLS 412A chassis)5. Side B, balanced CF connector: used to connect a DUT (for 412A) or a second chassis (411A)6. Side B, RJ-45 connector: used to connect a DUT (for 412A) or a second chassis (411A)7. Remote LED: indicates the remote status8. Power LED: indicates the power status9. Inactive Ports

2.4.1 Reading Remote and Power Status

Both the DLS 411A and DLS 412A chassis have 2 LEDs which indicate the power and remote status.

The POWER LED turns green when the power is turned on. The power LED blinks red if it fails its self-test, or solid red if it detects an internal error.

The REMOTE LED is off after a power-up or a reset. When the unit receives the first remote message, the REMOTE LED turns green if the command is valid or turns red if an error is detected. An invalid command or an out-of-range value will cause an error. The REMOTE LED stays red until the error flags are cleared (see the command *ESR? for more details). When the REMOTE LED is red, the unit can still communicate as normal, but you should investigate why the error occurred. Chapter 5 "REMOTE CONTROL" shows examples on how to read the ESR register, clear the error flags and make the REMOTE LED green once error conditions have been resolved.

2.4.2 Connecting the DLS 411A to the DLS 412A

To simulate ADSL 2++ test loops you need to connect two chassis together. Side B of DLS 411A connects to side A of DLS 412A. Use the RJ-45 cable provided as an accessory within the DLS 412A wireline simu-lator package. See Section 2.4.5 for RJ-45 connector details.

Note: The DLS 410A system is a combined two-chassis system. The software does not accept any single chassis of DLS411A or DLS412A.

2.4.3 Injecting Noise in the System

You can inject externally-generated impairments using the RJ45 connectors to the NA port on the front of the DLS 411A and to the NB port on the DLS 412A chassis. An external noise impairment generator, DLS 5200AP, can be purchased to inject noise differentially onto the wireline. See Section 2.4.5 for RJ-45 con-nector details.

Page 18: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 2-4 - Spirent Communications

7104000548-10/04-4

The DLS 5200AP Noise Generation System can generate both user-defined and pre-packaged noise shapes. It provides convenient noise injection circuitry for any of the test loops. For more information on the DLS 5200AP product, see the DLS 5204 Operating Manual.

To enable/disable the external noise injection ports, use remote control commands or the control software. It is not necessary to disconnect the cables from NA and NB ports.

2.4.4 Connecting to Analog Devices with CF Connectors

In a typical setup the Telephone Exchange (Central Office) equipment would be connected to Side A of the DLS 411A and the customer site equipment to Side B of the DLS 412A wireline simulator.

The CF connector is a balanced 3-pin (ring, tip, ground) connector. It is possible to use banana plugs instead of the CF connector, but note that the distance between the pins is not the 0.75" spacing used in North Amer-ica.

The DLS 410A ADSL 2++ Wireline Simulator provides bi-directional wireline simulation.

A CF plug looks like the diagram at the left. There are 3 prongs spaced unevenly, as shown. You can use banana plugs if the correctly spaced CF connector is not availa-ble.

Note that all 3-pin CF connectors on each side are balanced and connected in parallel.

WARNING: The maximum input to the DLS 410A should not exceed +/-200 V between Tip and Ring and 125 mA. Exceeding these limits could damage the unit.

2.4.5 Connecting to Analog Devices with RJ-45 Connectors (Adapters)

In a typical setup the Telephone Exchange (Central Office) equipment would be connected to side A of the DLS 411A and the customer site equipment to side B of the DLS 412A wireline simulator. The pinout of the RJ-45 female connector is shown in Figure 2.3.

In some cases, twisting of the Bantam connectors has introduced unwanted noise in testing. An RJ–45 con-nection resolves this problem.

Wiring

Figure 2.3 RJ-45 Female Connector

In Figure 2.3 "RJ-45 Female Connector", Pins 4 (Tip) and 5 (Ring) of the RJ-45 connectors, the center 2 pins, carry the signal.

Note: RJ-11 male connectors can also mate to RJ-45 female receptacles.

These connections are balanced. We recommend that these leads be shorter than 60 cm if you are using fre-quencies up to 4.5MHz. It is possible to use longer leads as the frequency decreases.

Page 19: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 2-5

7104000548-10/04-4

WARNING: The maximum input to the DLS 410A should not exceed +/-200 V between Tip and Ring and 125 mA. Exceeding these limits could damage the unit.

2.5 Back Panel Components and Connections

The connections on the rear panel are used for remote control (computer with DLS 410A Software), external noise injection and power. Figure 2.4 displays the key components of the rear panel.

4

123

5 6

7

Figure 2.4 DLS 410A Wireline Simulator Back Panel

DLS 411A and DLS 412A Back Panel Components

1) IEEE 488 Connector: for connection to a computer for remote control.2) RS–232 (DCE) Serial Connector: for connection to a computer for remote control 3) IEEE 488 Address DIP Switch: used to set a unique address for the unit4) Power Supply 5) Power Switch: for turning power to the unit on or off6) Power Input: for connecting to an AC power source7) Fuse Box: for fuse replacement when required

2.5.6 Connecting to Power

Each of the two DLS 410A chassis are built with a 2-fuse configuration. Please refer to Chapter 11 "SAFETY" for more details.

Connect the power input which can be found at the back of each of the two DLS 410A chassis to an AC line, voltage between 100 and 240 VRMS +/-10% and a frequency of 50 to 60 Hz. The DLS 410A can work with any voltage and frequency in this range, switch settings are not required.

When powered off, the DLS 410A remains latched to the previously selected loop settings, allowing the unit to be used when power is turned off.

Page 20: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 2-6 - Spirent Communications

7104000548-10/04-4

2.5.7 Connecting to a Windows Computer (for Remote Control)

You configure the DLS 410A ADSL 2++ Wireline Simulator remotely via a computer connected to either an IEEE 488 or an RS-232 interface on the rear panel of the simulator. There are two options available to con-trol the DLS 410A, one being Spirent Communications’s DLS 410A Software, or the second being custom software / scripting using commands sets.

The DLS 410A Software allows you to select the simulated length of the wireline loops and bridged taps. If you are developing custom control software, refer to Chapter 5 "REMOTE CONTROL" which discusses the accepted commands to configure the unit.

2.5.7.1 Connecting the Computer via the Serial Port (RS-232)

Connect one end of an RS-232 serial cable to the RS-232 connector located on the back panel of the DLS 411A chassis and the other end to a serial COM port connector on the computer. Connect one end of an RS-232 serial cable to the RS-232 connector located on the back panel of the DLS 412A chassis and the other end to a serial COM port connector on the computer.

The DLS 410A Software can be set to connect to serial port COM1 to COM9. Make sure there is no conflict with other serial devices.

2.5.7.2 Connecting the Computer via the IEEE 488 Port (GPIB)

The IEEE 488 portion of the control software supplied by Spirent Communications only works with a National™ IEEE 488 interface card. If necessary, install the National™ IEEE 488 interface card in the com-puter. Please refer to the “NATIONAL INSTRUMENTS GPIB CARD AND SOFTWARE INSTALLA-TION” for information on how to install the NI card.

Connect the IEEE port on the DLS 411A to the IEEE port on the DLS 412A with the IEEE cable provided. Connect the other end of the IEEE 488 cable to the IEEE 488 interface card in the computer.

No two units on the same IEEE bus can have the same IEEE 488 address. In association with the system, the DLS 411A and DLS 412A can use any two valid IEEE 488 addresses (from 0 to 30). You can change the address by using the DIP switch on the back of the unit. For more information see Section 5.1 "IEEE 488 Interface". The weighting is as follows:

Table 2-1:Dip Switch Weightings

Dip Switch Weighting

AD5 16

AD4 8

AD3 4

AD2 2

AD1 1

Page 21: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 2-7

7104000548-10/04-4

The following figure shows the default switch setting which is set to address 14 (i.e. 0+8+4+2+0=14) for the DLS 411A and 15 for the DLS412A:

Address 15Address 141

0

5 4 3 2 1

Page 22: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 2-8 - Spirent Communications

7104000548-10/04-4

Page 23: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 3-1

7104000548-10/04-4

3. DLS 410A SOFTWARE

3.1 About the Software

The DLS 410A ADSL2++ Wireline Simulator has its own control software. This chapter details the DLS 410A Software options for controlling these simulators.

Note: The DLS 410A system is a combined two-chassis system. The software does not accept any single chassis of DLS411A or DLS412A.

3.1.1 GPIB SettingsIf you connect the computer to the simulator via the IEEE 488 (GPIB) port, ensure you install the National Instruments GPIB - PC II/IIA or PCMCIA card and its associated software in your computer. Here is a list of steps you should follow to ensure your GPIB set-up is correct.

1) Board level configuration

Make sure the GPIB board is configured properly. The easiest way to do this is to open the Measurement & Automation Explorer that is installed with the National Instruments software. To open the Measurement & Automation Explorer explorer go to Start--> Programs--> National Instruments--> Measurement and Auto-mation. .

Figure 3.1 Measurement and Automation Explorer

Page 24: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 3-2 - Spirent Communications

7104000548-10/04-4

Right-click on the GPIB interface and set the default parameters as follows:

1) disable automatic serial polling2) disable high speed data transfer3) enable system controller4) enable "Assert REN when SC"5) enable "Send EOI at end of write"6) set I/O timeout set to be at least 10s. If the timout is less than the typical time the command takes to

complete then the function returns while the command is still executing

For more information please refer to National Instruments device-specific documentation and on-line help. .

3.1.2 Computer Hardware and Software Requirements

You require the following to configure and control a simulator through either the serial port or IEEE 488 interface:

• If using the DLS 410A Software (provided with the unit):

• a computer running a version of the Windows® based operating system. • National Instruments GPIB-PCII/GPIB-PCMCIA, and• IEEE 488 cable

OR

• Serial port, and• RS-232 serial cable.

The DLS 410A Software provided by Spirent Communications allows the control of the DLS 410A units either through an RS-232 or IEEE 488 interface. Please see the release notes of the DLS 410A Software for a list of the current versions of Windows supported.

• Control of the simulator may also be done through writing custom software to send commands over the RS-232 or IEEE 488 port. See Chapter 5 "REMOTE CONTROL" for details about accepted commands.

3.2 Installing the Software

Insert the DLS 410A Software Installation CD in the computer CD drive.The Setup Wizard is displayed if the CD autorun is enabled (in Windows). If the Setup Wizard does not appear, click the Start button, click Run and type <drive>: \setup. For example, if the CD-ROM is the E drive, type E:\setup. Once the Installa-tion Wizard starts, simply follow the instructions on the Wizard’s series of dialog boxes.

You will be given the option to install the DLS Terminal after the DLS 410 software has been installed. It is highly recommended that you install the DLS terminal by choosing the ’Install DLS Terminal’ checkbox pictured in Figure 3.2. The DLS Terminal is a useful tool for sending and receiving commands to and from each of the simulator units.

Page 25: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 3-3

7104000548-10/04-4

Figure 3.2 Final Screen for DLS 410A Software Installation

3.2.3 Starting the Software

You can find the program executable file in the default installation folder: C:/Program Files/Spirent Commu-nications/DLS 410A/DLS 410A.exe. Right-mouse click on the file name to create a short-cut to your desk-top.

To access the main window:

From the Start menu, select Program Files>Spirent Communications> DLS 410A> DLS 410A or double-click the icon on your desktop. The DLS 410A window appears.

3.2.4 Accessing the Control Window (s)

The DLS 410A control window has three tabs; one is for setting system properties, one for doing system compensation, and one for setting the communication interface.

The control window also displays a Loop Drawing area and a Command Logs area. The Loop Drawingarea graphically displays the simulated loop. The Command Logs area lists the controls commands being sent from the control computer to the wireline simulator.

The System Properties tab appears active in the DLS 410A by default. At any time you can access system properties by clicking the tab title.

Page 26: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 3-4 - Spirent Communications

7104000548-10/04-4

Figure 3.3 System Properties Tab - All Loops (Uncompensated)

Page 27: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 3-5

7104000548-10/04-4

Figure 3.4 System Properties Tab - Standards-Based Loops (Compensated)

Page 28: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 3-6 - Spirent Communications

7104000548-10/04-4

Figure 3.5 System Properties Tab - Custom Loops (Compensated)

Page 29: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 3-7

7104000548-10/04-4

To access the System Compensation settings:

In the DLS 410A window, click the System Compensation tab. The DLS 410A window appears with the System Compensation Tab active.

Figure 3.6 System Compensation Tab

Page 30: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 3-8 - Spirent Communications

7104000548-10/04-4

To access the communications interface settings:

In the DLS 410A window, click the Communication Settings tab. The DLS 410A window appears with the Communication Interface Tab active.

Figure 3.7 DLS 410A Control Software - Communication Settings Tab

Page 31: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 3-9

7104000548-10/04-4

3.2.5 Accessing the Advanced Settings

For additional information required for troubleshooting or resetting the unit, in the DLS 410A window click the Advanced button.

The Advanced dialog box appears.

Figure 3.8 Advanced Dialog Box

The Advanced Dialog box can only be accessed when the GUI is in ’Online’ mode.

3.3 Configuring the DLS 410A

You can vary up to six segments that represent the wireline length settings of the system depending on the loop, as shown in Figure 1.2 "Straight Loop Topology". The simulator configures dynamically as you change values in the software.

3.3.1 Identifying Simulator Connection

The software does not allow control of multiple DLS 410A units via the IEEE 488 interface. In the DLS 410A- Communication Interface window, set the following fields as follows:

Page 32: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 3-10 - Spirent Communications

7104000548-10/04-4

Unit Selection

Click the down-arrow and select the chassis you wish to set communication properties for from the drop down list. Your choices are: 411A and 412A.

Communication Interface

Click the down-arrow and select the appropriate connection type between the desired chassis and the computer from the drop down list. Your choice affects the GPIB Address/ComPort field. Your choices are: GPIB (IEEE 488.2) or Serial (RS-232).

GPIB Address

If you selected IEEE 488 in the Connection field, click the down-arrow and select the appropriate IEEE 488 (GPIB port) address of the simulator you wish to configure from the drop down list. Your choices are: 1- 30. The default IEEE 488 address is 14. Factory address settings for the DLS 411A and DLS 412A are 14 and 15 respectively.

OR

ComPort

If you selected Serial in the Connection field, click the down-arrow and select the appropriate serial port (RS-232 port) address of the simulator you wish to configure from the drop down list. Your choices are: 1- 9. The default RS-232 address is 1. Factory address settings for the DLS 411A and DLS 412A are 1 and 2 respectively.

3.3.2 Software Communication with the Wireline Simulator

In the DLS 410A window, press the Go OnLine button to start communication between the software inter-face and the DLS 410A sytem.

Any unit other than DLS 410A cannot be connected to the system. For example, if you try to connect DLS 400E3 units to the system, a message box appears with the error message "Errors occurred while connecting with the target system". The system remains in Offline mode.

If an incorrect communcation interface or address was selected in the ’Communcation Settings’ win-dow, a message box appears with the error message "Errors occurred while connecting with the target system".

The single unit of DLS 411A or DLS 412A cannot be connected to the system. If you try to connect a single unit of DLS 411A or a single unit of DLS 412A to the system, a message box appears with the message "The DLS 410A system is a combined two-chassis system. The software does not accept any single chassis of DLS411A or DLS412A". The system remains in Offline mode.

Press the Go OffLine button to disconnect the software interface from the wireline simulator.

3.3.3 Configuring the Loop Length Mode

In the DLS 410A - System Properties tab, Loop Mode Selection area, the values you set in the following fields allow you to use a compensated or non-compensated loop length.

Loop Mode Selection

Click the appropriate option button for the desired loop length mode. Your choices are:

• All Loops (Uncompensated)- uses factory default settings.

Page 33: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 3-11

7104000548-10/04-4

• Custom Loops (Compensated) uses the compensated values from a .csv file located under the "cust" directory in the DLS 410A control software directory. C:\program files\spirent commu-nications\DLS 410A\cust. Using this mode enables the Browse button you must select a com-pensation file for this particular unit.

• Standards-Based Loops (Compensated) - uses the compensation file to set standard based loop lengths. Using this mode enables the Browse button, you must select a compensation file for this particular unit (see Figure 3.4 "System Properties Tab - Standards-Based Loops (Com-pensated)". The standards based file is located in C:\program files\spirent communica-tions\DLS410A\comp directory.

Compensated files are in a ’csv’ format and can be used with any standard or custom loop to ensure the Mean Absolute Error for that loop is less than 0.5 dB. Compensation files are one of the following types:

a) Factory Compensation Files - These ’csv’ files are shipped on diskette with the DLS 410A unit and should be saved on the control PC, a custom loop and standard based loop file is provided.

b) System Compensation Results File - This file can be of two types:

Standards-Based Loops (Compensated) File: This file contains 208 standard loops, and is compatible with DLS 410A v 2.1 software. The DLS 410A software by default will save this file in the working directory\comp directory. ie: if the working directory of the DLS 410A software is C:\Program Files\Spirent Communcations\410A, the compensation file will be saved in the C:\Program Files\Spirent Communcations\410A\comp directory. The compensation file name will be time and date stamped, and will also contain the serial number of the system. as an example: DLS410A_DL43726_DL43723_2004_02_06-09_07_06-Comp.csv where

DL43726_DL43723: represents the serial numbers of the two chassis; DLS 411A and DLS 412A, repectively. The serial numbers in the compensation results file must match the serial numbers of the units connected.

2004_02_06: represents the date that the system was compensated; Feb 6/2004

09_07_06: represents the time of day the system compensation test was started; 09:07:06 am, 9(hours), 7(minutes), 6(seconds)

-Comp: indicates that this is a standards based compensation file Only complete compensation results can be used with the DLS 410A software. Incomplete tests will contain the suffix ’-Incomplete’ in the name. ie: DLS410A_DL43726_DL43723_2004_02_05-10_22_10-Comp-Incomplete.csv

Custom Loops (Compensated) File: This file contains several thousand compensated loop segments and contains all the optimized settings for each loop segment L1-L6. which are not part of the standard based loops. The DLS 410A software by default will save this file in the working directory\cust direc-tory. As an example, if the working directory of the DLS 410A software is C:\Program Files\Spirent Communcations\410A, the compensation file will be saved in the C:\Program Files\Spirent Communca-tions\410A\cust directory. The compensation file name will be time and date stamped, and will also contain the serial number of the system. as an example: DLS410A_DL43726_DL43723_2004_02_06-09_07_06-Cust.csv where

DL43726_DL43723: represents the serial numbers of the two chassis; DLS 411A and DLS 412A, repectively. The serial numbers in the compensation results file must match the serial numbers of the units connected.

2004_02_06: represents the date that the system was compensated; Feb 6/2004

09_07_06: represents the time of day the system compensation test was started; 09:07:06 am, 9(hour), 7(minute), 6(second)

Page 34: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 3-12 - Spirent Communications

7104000548-10/04-4

• Browse - This button is only available when Compensated Loop has been selected in the Loop Mode Selection field. Click the button to open a standard Windows Open dialog box and navi-gate to and select the appropriate previously saved compensation file for the unit to be control-led.

3.3.4 Selecting the Cable Model

In the DLS 410A - System Properties tab, Cable Model area, the values you set in the following field allow you to select a Cable Model mode.

Cable Model

Click the appropriate option button for the desired cable simulation model. The two choices are mutu-ally exclusive, choices are:

• T1.417 (default) - This is the standard cable model specified by the ADSL 2++ standard G.992.5, which specifies the R,L,C and G parameters of the cable. Select this model when per-forming ADSL2++ testing.

• G.996.1 - This is the standard cable model specified by the TR-048 and TR-067 standard, which specifies the R,L,C and G parameters of the cable. Select this model when performing TR-048 and or TR-067 testing.

3.3.5 Selecting the Test Loop

In the DLS 410A - System Properties tab, Loop Navigation area, the values you set in the following field allow you to select one of the test loops.

Loop Types

Click the down-arrow and select the appropriate test loop from the drop down list. Your choice affect all fields in the Wireline Length(s) area. Your choices are:Straight loop (default), Bridged Tap, ANSI 13 (standard), ANSI 13 (Modified 1), ANSI 13 (Modified 2) and CSA4 (standard).

Once a loop is selected from the Loop Types field, the Wireline Length(s) area is filled with the stan-dard lengths for wireline segments L1, L2, etc. The lengths of these segments can now be adjusted to create a custom (non-standard) loop. Note that custom loops will not be compensated using the compen-sation file. Once a custom loop has been created, the Go To Loop Navigation button appears (see Fig-ure 3.5 "System Properties Tab - Custom Loops (Compensated)").

3.3.6 Selecting the Loop Simulation

In the DLS 410A - System Properties tab, Loop Simulation area, the values you set in the following field allow you to select one of loop simulation modes.

Loop Simulation

Click the appropriate option button for the desired loop simulation. Your choices are:

• Normal (default) - Includes the two-chassis wireline simulator in the circuit (with the line seg-ment lengths set in the Wireline Length field).

• Bypass - Bypasses the two-chassis wireline simulator in the test system (short circuit between A of DLS 411A and B of DLS 412A).

• Disconnect - Disconnects the two-chassis wireline simulator from the test system (open circuit between A of DLS 411A and B of DLS 412A).

Page 35: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 3-13

7104000548-10/04-4

3.3.7 Controlling the DLS 410A Noise Injection Ports

The software will acknowledge introduction of two external noise sources or a single analog device under test via the selected chassis’s front panel RJ-45 ports NA and NB. In the DLS 410A - System Properties tab, External Noise Injection area, the following fields allow you to switch these ports ON or OFF.

(Noise) Source A

Check this check box to switch the NA port of the DLS 411A ON and include the connected analog device in the test circuit. Clear this check box to switch the port OFF. The default setting is disabled.

(Noise) Source B

Check this check box to switch the NB port of the DLS 412A ON and include the connected analog device in the test circuit. Clear this check box to switch the port OFF. The default setting is disabled.

3.3.8 Configuring the Length of the DLS 410A Line Segments

The DLS 410A configures the length of the line segment L1 - L6 in the DLS 410A - System Properties tab, Wireline Length (s) area. The values you set in the following fields are dynamically reflected in the loop diagram shown in the window. When you change the length of one or more segments, it resets distances in both units. Changing lengths in this area creates a custom loop and makes the Go to Loop Navigation but-ton available.

Go to Loop Navigation

This button is only available once a custom loop has been created. Click the button to choose standard loop types in the Loop Navigation area.

Segment (L1 to L6)

L1 to L6 will appear on the screen, depending on which loop type is selected.

Cable Type

Displays the appropriate cable type for each line segment as required by the test loop selected in the Loop Types field.

Current Length (ft)

Click the up or down arrows to select the desired cable length in feet for each line segment or type directly in the field.

Note: To set the entire loop length to zero, set the Loop Simulation field to Bypass. This bypasses the unit thus simulating 0 feet.

Your choices are:

1. Straight loop (segment 1 is displayed)

• L1 - 26 AWG (default setting of 9000 ft, ranging from 0 to 23000 ft, allowing incremental set-tings of 50 ft)

2. Bridged Tap(two segments L1 and L2 are displayed)

• L1 - 26 AWG (default setting of 9000 ft, ranging from 0 to 23000 ft, allowing incremental set-tings of 50 ft)

Page 36: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 3-14 - Spirent Communications

7104000548-10/04-4

• L2 - 24 AWG (default setting of 0 ft, ranging from 0, 50 to 1500 ft, allowing incremental set-tings of 10 ft from 50 to 1500ft)

3. ANSI 13 (standard/modified 1/modified 2) loop (six segments L1 - L6 are displayed)

• L1 - 26 AWG (default setting of 9000 ft for ANSI standard, 1000 ft for modified 1, 2000 ft for modified 2, ranging from 0 to 9000 ft, allowing incremental settings of 50 ft)

• L2 - 24 AWG (default setting of 2000 ft, ranging from 0 to 2000 ft, allowing incremental set-tings of 50 ft)

• L3 - 26 AWG (default setting of 1500 ft, ranging from 0, 50 to 1500 ft, allowing incremental settings of 10 ft from 50 to 1500ft)

• L4 - 24 AWG (default setting of 500 ft, ranging from 0 to 500 ft, allowing incremental settings of 50 ft)

• L5 - 26 AWG (default setting of 1500 ft, ranging from 0, 50 to 1500 ft, allowing incremental settings of 10 ft from 50 to 1500ft)

• L6 - 24 AWG (default setting of 500 ft, ranging from 0 to 500 ft, allowing incremental settings of 50 ft)

4. CSA 4 (standard) loop (five segments L1 - L5 are displayed)

• L1 - 26 AWG (default setting of 550 ft, ranging from 0 to 550 ft, allowing incremental settings of 50 ft)

• L2 - 26 AWG (default setting of 400 ft, ranging from 0, 50 to 400 ft, allowing incremental set-tings of 10 ft from 50 to 400 ft)

• L3 - 26 AWG (default setting of 6250 ft, ranging from 0 to 6250 ft, allowing incremental set-tings of 50 ft)

• L4 - 26 AWG (default setting of 800 ft, ranging from 0, 50 to 800 ft, allowing incremental set-tings of 10 ft from 50 to 800ft)

• L5 - 26 AWG (default setting of 800 ft, ranging from 0 to 800 ft, allowing incremental settings of 50 ft)

Range (ft)

Displays the minimum and maximum values of line length in feet as required by the test loop selected in the Loop Types field.

3.3.9 Accessing Advanced Information About the Unit

The Advanced dialog box gives more information about the unit, mainly for the purpose of troubleshooting. To open the Advanced dialog box, in the DLS 410A window click the Advanced button. The advanced dia-log box can only be opened in ’Online’ mode.

The Wireline Card area displays information about the wireline cards in the unit.

Slot #

Displays the wireline slot numbers from 1 to 29.

Card ID

Displays wireline card ID number in each slot.

Page 37: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 3-15

7104000548-10/04-4

Status

The OK information in each slot indicates that the proper line card is in each slot.

The Communication Settings area displays information about the system’s interface settings.

Interface

Displays the current interface type between the unit and the control computer. The field can display: The IEEE 488 or Serial.

Interface Address

Displays the interface address.

The General Settings area displays information about the system.

System Error

Displays the results of the system self-check. A"0" indicates no error, and a "1" indicates an error. If an error has occured, please contact the customer service department.

Firmware Checksum

Displays a number that indicates the firmware revision.

Last Calibration Date

Displays the date of the last calibration.

Calibration Due Date

Displays the due date for the next calibration.

3.3.10 Using The DLS Terminal Window

The DLS Terminal window is a useful tool that is included with the DLS 410A software. This window allows the user to send commands and receive responses directly from the unit. To open the DLS Terminal window, choose Start-->Programs--> Spirent Communication--> DLS Terminal-->DLS Terminal.

Page 38: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 3-16 - Spirent Communications

7104000548-10/04-4

Figure 3.9 DLS Terminal Window

To connect to a unit, choose the communication interface for the unit, and hit the ’Attach’ button. Com-mands and queries can be typed in the terminal window, and the response will be displayed on the screen.

One terminal window can only be connected to one unit at a time. To connect to both the DLS 411A and the DLS 412A simultaneously, you must open 2 terminal windows, and connect one window to the 411A, and the other window to the 412A.

Page 39: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 4-1

7104000548-10/04-4

4. PERFORMING SYSTEM COMPENSATION TESTS

4.1 OverviewThe DLS 410A software contains system compensation measurement functionality.

A system compensation test is an automated test which measures the actual attenuation for all standard and custom loops on the DLS 410A. The loops are then compensated to a length such that the mean absolute error (MAE) for each loop is <.5 dB, and mean error (ME) is minimized over the frequency range specified. These compensated length settings are then stored in a results file, along with the MAE and ME values for all loops. Compensated length settings may then be automatically applied in the GUI, by choosing a ‘Com-pensated Loop’ under the Loop Mode Selection area, and browsing to choose the appropriate results file. Automated scripts can also apply compensation by using the results files to determine length settings.

4.2 Required Equipment

The system compensation test requires the following equipment:1) DLS 410A Wireline Simulator2) Agilent (HP) 4295A Spectrum/Network Analyzer3) 2 x 50/100Ohm transformers (see Chapter 4.6 "Connection Accessories" for more details.)

4.3 Accessing the System Compensation Software

To access the System Compensation software, open the DLS 410A software, and choose the ‘System Com-pensation’ tab. The software will appear as follows:

Figure 4.1 System Compensation Window

Page 40: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 4-2 - Spirent Communications

7104000548-10/04-4

The System Compensation area displays information about the system compensation test.

4.3.1 HP 4395A Analyzer SettingsRunning a system compensation test requires a HP (Agilent) 4395A Spectrum/Network Analyzer, connected to the control PC via a GPIB (IEEE-488.2) cable. The following fields should be set before running a test:

Address

Choose the correct GPIB address of the HP (Agilent) 4395A Spectrum/Network Analyzer.

Normalize before performing compensation

This box is checked by default. It is recommended to have this box checked, so that the analyzer will be nor-malized before performing compensation tests. Once the compensation test is started, the DLS 410A soft-ware will prompt for the correct connections for normalization, before proceeding with system compensation.

4.3.2 Frequency Range Settings

Before starting a test, a frequency range must be specified. The frequency range of the test should be the same or greater than the frequency range of the signals that will be tested on the DLS 410A. Specifying a smaller frequency range will decrease the amount of time taken to complete a system compenation test.

Lower Boundary

This setting indicates the lower frequency limit of the range over which compensation measurements are taken.This setting cannot be changed from 20 KHz.

Upper Boundary

This setting indicates the upper frequency limit of the range over which compensation measurements are taken. The choices are 1.11 MHz, 2.21 MHz and 4.42 MHz.

4.4 General ProcedureThe general procedure for setting up and running the system compensation is as follows:

1) Power on the 4395A analyzer and the DLS 410A system. Let the 4395A warm up for 30 minutes before beginning measurements.

2) Connect the Agilent 4395A Spectrum Analyzer and DLS 410A chassis one and two to the control computer via IEEE cable and GPIB control card. (see Figure 4.2 "System Compensation Control Connections for DLS 410A"

3) On the control PC, start the DLS 410A software.4) Under the ‘System Compensation’ tab - HP 4395A settings, choose the GPIB address of the

4395A.5) Under the ‘System Compensation’ tab - Frequency Range settings, choose desired lower limit and

upper limit frequency boundaries. Note that compensation values will NOT be valid for frequency ranges outside of the limits specified.

6) Ensure the GUI is in ‘Offline’ mode. Press ‘Start’. 7) Follow connection instructions as prompted by the DLS 410A software. Figure 4.3 illustrates the

connections required for all loop measurements

Page 41: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 4-3

7104000548-10/04-4

Figure 4.2 System Compensation Control Connections for DLS 410A

Page 42: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 4-4 - Spirent Communications

7104000548-10/04-4

Figure 4.3 System Compensation Measurement Connections for DLS 410A

4.5 Mean Absolute Error (MAE) and Mean Error (ME) MeasurementsFor every standard loop on the DLS 410A, System Compensation function automates the measurement and calculation of the MAE. The MAE for loop attenuation is measured over the range[f1,f2], where frequency f1 is 20 kHz. The frequency f2 is the frequency at which the loop attenuation is 90dB or the upper boundary frequency as specified in the Frequency Range settings, whichever is lowest.

The System Compensation function calculates the MAE and ME for loop simulation as follows:

Page 43: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 4-5

7104000548-10/04-4

N is determined by the number of points necessary to measure the attenuation in steps of 10 kHz.The theo-retical values are calculated for two types of cables

1) The RLCG parameters using two-port ABCD modelling methodology as specified in ANSI T1.417 Section B.3.1.

2) The RLCG cable parameters using two-port ABCD modelling methodology as specified in ITU-T Rec. G.996.1 (June 1999)(PIC cable at 70 degrees Fahrenheit)

Compensation values for both cable models are stored in the results file. The correct compensation will be applied, according to the cable model selected on the ‘System Properties’ tab.

4.6 Connection Accessories

The system compensation test requires some connection accessories that are not included with the DLS 410A package. Specifically, two 50 unbalanced/100 ohm balanced transformers are required. Spirent recom-mends using a 1kHz -20Mhz wideband transformer from North Hills (model 0311LB) with connections as shown in Figure 4.4 "Accessories Required for System Compensation Test (2 required)". Optionally, the 4A03 transformer may be be purchased from Spirent Commincations and used in measurements. The con-nections required for performing the system compensation test are shown in Figure 4.3 "System Compensa-tion Measurement Connections for DLS 410A".

The center pin of the 100 ohm side of the transformer is to be connected to the case of the transformer. The other 2 pins on the 100 ohm side of the transformer are to be connected to the wires that connect to pins 4 and 5 of the RJ-45 connector

.

Figure 4.4 Accessories Required for System Compensation Test (2 required)

4.7 Output and Results After the system compensation test is complete, the results are stored in a csv file. The file is stored in the ‘comp’ folder OR ‘cust’ folder in the working directory of the DLS 410A software The directory which is used is based on if the ‘custom loops’ or ‘standard-based loops’. For example, if the working directory of the DLS 410A software is C:\Program Files\Spirent Communications\DLS 410A, then the file will be stored in the C:\Program Files\Spirent Communications\DLS 410A\comp directory or cust directory.

The compensation file name will contain the serial number for the system, as well as the time and date that the test was completed. ie: DLS410A_SN1XXXX_SN2XXXX_YYYY_MM_DD-HH_NN_SS.csv’ where

Page 44: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 4-6 - Spirent Communications

7104000548-10/04-4

SN1XXXX = serial number of chassis 1

SN2XXXX= serial number of chassis 2

YYYY= year the test was completed

MM =month the test was completed

DD = day the test was completed

HH = hour the test was completed

NN = minute the test was completed

SS = second the test was completed.

For example, ‘DLS410A_DL43726_DL43723_2004_02_26-09_07_06-.csv’, where DL43726 and DL43723 are the serial numbers of chassis 1 and 2, respectively. ‘2004_02_06-09_07_06’ indicates that the test was completed at 9:07:06 am, on 2004/02/06.

Incomplete test results will also contain the string ‘-Incomplete’ at the end of the name. ie: DLS410A_DL43726_DL43723_2004_02_06-09_07_06--Incomplete.csv’. Incomplete files cannot be used for compensation.

To apply compensation in the DLS 410A software, users should choose ‘Compensated Loop’ in the Loop Mode selection box of the DLS 410A GUI, and then choose the ‘Browse’ button, to find the compensation file for the system that is connected.

IMPORTANT: The DLS 410A software version 2.1 or higher must use compensation files generated by the DLS 410A software version 2.1 or higher. Previously generated compensation files or factory compensation files cannot be used.

Figure 4.5 Excerpt from Compensation File

The format of a compensation file is shown in Figure 4.5 "Excerpt from Compensation File". For automated scripts, the .csv file provides the M1, M2 and M3 values that should be sent to both chassis in order to set

Page 45: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 4-7

7104000548-10/04-4

compensated loop length settings. All M1, M2 and M3 values are shown for both chassis, with a loops ID number to identify the loop.

The compensation file assigns an ID number to each standard based compensated loop. This ID number cor-responds to the ID number supplied with the DLS_410A_LoopLength_Setting.csv file (shipped with DLS 410A), which shows which length is set for a particular loop ID number. ie:

Figure 4.6 Excerpt from DLS_410A_LoopLength_Setting.csv file

In Figure 4.6 "Excerpt from DLS_410A_LoopLength_Setting.csv file" , we can see that the loop ID number is 4, for a straight loop of 2.5 kft. Only standard loops as set by the DLS 410A software have a loop ID number, and thus only standard loops can be compensated.

For more information on controlling and propramming the DLS 410A, please reference Chapter 5 "REMOTE CONTROL".

4.8 Spectrum/Network Analyzer Settings

The system compensation test requires an Agilent 4395A Spectrum/Network Analyzer to make loop attenu-ation measurements. The system compensation test automatically makes all the required settings on the ana-lyzer during measurements.

Page 46: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 4-8 - Spirent Communications

7104000548-10/04-4

Page 47: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 5-1

7104000548-10/04-4

5. REMOTE CONTROL

The DLS 410A is controlled via the IEEE 488 (also known as the GPIB bus), or the RS-232 (serial) inter-face, allowing the integration of the DLS 410A into a larger test system.

The DLS 410A remote control is designed with several standards in mind:

• The GPIB physical interface follows IEEE 488.1. The functions implemented are outlined in the IEEE 488 Interface section.

• The Common Commands follow IEEE 488.2.

• The Device Dependent Commands (see 6) are based upon the Standard Commands for Programmable Interfaces (SCPI).

• The serial port physical interface follows the EIA RS-232 standard.

The IEEE 488 and the serial interfaces are always enabled and either can be used. The DLS 410A directs its output to the last interface from which it received data. Both interfaces use the same command set and pro-duce the same results.

5.1 IEEE 488 InterfaceThis section contains information specific to the IEEE 488 interface. Section 5.2 contains the information specific to the RS-232 interface.

5.1.1 IEEE 488.1 Interface Functions SupportedThe IEEE 488.1 Interface functions supported by the DLS 410A are as follows:

SH1 Source handshake - full capabilityAH1 Acceptor handshake - full capabilityT5 Basic talker - serial poll, untalk on MLAL3 Basic listener - unlisten on MTASR1 Service request - fullDC1 Device clear - fullC4 Respond to SRQE1 Open Collector driversRL1 Remote Local - full

These represent the minimum required to implement the IEEE 488.1 standard.

Note that the IEEE 488 interface is also known as the GPIB and the HP-IB interface.

5.1.2 IEEE 488 Address

The DLS 411A and DLS 412A can use any valid IEEE 488 address (from 0 to 31). The DLS 411A and DLS 412A must have different IEEE 488 addresses. The factory settings are:

• Address 14 for the DLS 411A

• Address 15 for the DLS 412A

Page 48: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 5-2 - Spirent Communications

7104000548-10/04-4

The address can be changed by using the DIP switch on the back of the unit. The weighting is as follows:

Address 14 Address 15

Note that by default, the National Instruments IEEE 488 interface card will use address 0.

5.1.3 The Service Request (SRQ) Line

The SRQ line, as defined by the IEEE 488.1 standard, is raised when the DLS 410A is requesting service. Here are some examples of services that could raise SRQ:

•a message is available in the output buffer

•an error occurred

•all pending operations are completed

•the power was just turned on

In order to use the SRQ line, all relevant enable bits must be set.

For example:

•the SRQ line can be raised automatically when there is a message available by enabling the MAV bit (bit 4) in the Status Byte Register with the command *SRE 16.

•the SRQ line can be raised automatically when there is an error by enabling the ESB bit (bit 5) in the Status Byte Register with *SRE 32 and by enabling the error bits in the Standard Event Status Reg-ister with *ESE 60 (bit 2, 3, 4 and 5).

NOTE: The Factory default is to clear all enable registers on power up. See *ESE and *SRE com-mands for more details.

We recommend that you set the DLS 410A to raise the SRQ line when there is a message available and when there is an error.

5.1.4 Message Terminators

Messages to the DLS 410A must be terminated with either a Line Feed character (ASCII <LF>, decimal 10, hex 0A), an IEEE 488.1 EOI signal, or both. Messages from the DLS 410A are always terminated with a Line Feed character and the IEEE 488.1 EOI signal.

Page 49: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 5-3

7104000548-10/04-4

Note that some languages, such as BASIC, may automatically append a carriage return and a line feed at the end of messages. The carriage return character is not a valid terminator, and will invalidate the last com-mand. To avoid this problem, you can append a semi-colon after a string (after the quotes) when printing to the IEEE 488 port. Another solution is to append a semi-colon at the end of the command itself (inside the quotes), so that the carriage return can be interpreted as a second command, and be simply discarded by the DLS 410A.

For example:

PRINT #1, “:SETTING:CHANNEL:STATE?”+CHR$(10); Preferred solutionor

PRINT #1, “:SETTING:CHANNEL:STATE?;” Other solution

5.1.5 Example using the IEEE 488 Interface

To send and receive messages with error checking follow these steps:

• set all relevant enable bits (only done once)• send the message• wait for SRQ• read the Status Byte• if MAV (bit 4) is set, then read the response• if ESB (bit 5) is set, then read the Standard Event Status Register and take all the relevant

actions.

Table 4-1:Setting the ID message with IEEE 488Action Comment

transmit “*SRE 48” enable MAV and ESB (needed only once)

transmit “*ESE 60” enable all the error bits (needed only once)

transmit “*IDN?” query the identification message

wait for SRQ to be raised

read the status byte use the IEEE 488.1 serial poll command, not *STB?

if MAV (bit 4) is set, read the response

if ESB (bit 5) is set, do the following: check if an error was detected

transmit “*ESR?” query the Event Status Register

wait for SRQ to be raised

if MAV (bit 4) is set, read the response and take all relevant action according to the error type received

For example, to get the identification message with the IEEE 488 interface, do the following:

5.2 RS-232 Serial InterfaceThis section contains information specific to the RS-232 interface. Section 5.1 contains the information spe-cific to the IEEE 488 interface.

The system uses a female DB-25 connector, and is configured as a DCE device. It can be connected directly to your PC serial port.

Page 50: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 5-4 - Spirent Communications

7104000548-10/04-4

Do NOT use a null modem with a computer that has a standard COM port configured as a DTE.

To use the RS-232 interface, simply connect your computer to the host system and set the computer to 9600 bps baud rate, no parity, 8 data bits per character, 1 stop bit and RTS/CTS hardware flow control.

The RS-232 standard is equivalent to the European V.24/V.28 standards. In this manual we use the term RS-232 to refer to both of these two standards. Generally, the computer literature will use the words “serial”, “COM1” and “COM2” to refer to the RS-232 interface. Note that the DLS 410A cannot use the parallel port of a computer (the female connector).

The system stops transmitting data when the RTS line is low, and restarts when the RTS line is high. The DLS 410A lowers the CTS and the DSR lines when it cannot accept data, and raises them when it can. Note that the RTS line is not the usual “Request To Send” as defined by the RS-232 standard. If desired, the user can leave the RTS line set, and use only the CTS line.

Most serial port communication programs can be used to control the DLS 410A.

To use HyperTerminal:

1. Select “Start” >> “Programs” >> “Accessories” >> “HyperTerminal” >> “hypertrm.exe”. The program starts.

2. Enter a name (for example; “DLS 410A”.)3. Select the port (for example; “Direct to COM1”).4. Enter the port settings: 9600, 8, none, 1 and hardware.5. Select “File” >> “Properties” >> “Settings” >> “ASCII Setup”6. Enable “Send line ends with line feeds” and “Echo typed characters locally”7. Click OK twice. You should now be able to send and receive commands to and from the system.

5.2.1 Message TerminatorsMessages sent to the DLS 410A through the serial interface MUST be terminated with the line feed charac-ter (decimal 10, hex 0A, LF). To ensure that no characters are left in the receive buffer of the DLS 410A from a previous incomplete command, you can send the line feed character by itself before sending new commands.

Messages from the DLS 410A are always terminated with a Line Feed character.

Note that some languages, such as BASIC, may automatically append a carriage return and a line feed at the end of messages. The carriage return character is not a valid terminator, and will invalidate the last com-mand. To avoid this problem, you can append a semi-colon after a string (after the quotes) when printing to the Rs-232 port. Another solution is to append a semi-colon at the end of the command itself (inside the quotes), so that the carriage return can be interpreted as a second command, and be simply discarded by the DLS 410A.

For example:

PRINT #1, “:SETTING:CHANNEL:STATE?”+CHR$(10); Preferred solutionor

PRINT #1, “SETTING:CHANNEL:STATE?;” Other solution

5.2.2 Example using the RS-232 Interface

To send and receive messages with error checking follow these steps:

• set all relevant enable bits (only done once)• send the message• read the answer until you receive LF (decimal 10, hex 0A)

Page 51: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 5-5

7104000548-10/04-4

• check if an error occurred with the command *ESR?

For example, to get the identification message with the RS-232 interface, do the following:

Table 4-2:Setting the ID message with RS-232Action Commenttransmit "*ESE 60 enable all the error bits (needed only once)transmit "*IDN? query the identification messageread the answer the messages are always terminated with LFtransmit "*ESR? check if an error occurredread the answer if not 0, error occurred, see Event Status Register (ESR)

Section for a description of the error(s)

5.3 Command SyntaxThe DLS 410A adheres to the IEEE 488.2 format for command syntax. As with the Data Format, the princi-ple is Forgiving Listening and Precise Talking.

Commands may take one of two forms: either a Device Dependent Command or a Common Command. The format of the former is detailed in Section 4.5, the format of the latter in Section 4.6. Each type may be pre-ceded by one or more spaces, and each must have one or more spaces between its mnemonic and the data associated with it.

Common commands are preceded by the character “*”. A colon precedes Device Dependent commands and a colon separates each level of the command. Commands may be either in upper or lower case. Multiple commands may be concatenated by separating each command by semi-colons.

The following are some examples:

*RST*RST;*WAI;:SETTING:CHANNEL:STATE Normal*ESE 45; *SRE 16Messages to the DLS 410A must be terminated with a Line Feed character (ASCII <LF>, decimal 10, hex 0A). Messages from the DLS 410A are always terminated with a Line Feed character.

As defined in the SCPI specifications, a Device Dependent Command may be sent in its short form or long form, in upper or lower case. The following commands are therefore identical in operation:

:SETTING:CHANNEL:STATE Normal:SET:CHAN:STA NormalNote that the parameters cannot be shortened.Queries of the system follow the same format as the commands, except that the data normally associated with a command is replaced by a question mark “?”. Following receipt of such a command, the DLS 410Awill place the appropriate response in the output queue, where the controller can read it.

Examples are:

*IDN?*ESE?;*SRE?:SET:CHAN:STA?

Page 52: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 5-6 - Spirent Communications

7104000548-10/04-4

5.4 DEVICE DEPENDENT COMMAND SET The DLS 410A is comprised of two chassis (the DLS 411A and DLS 412A). As recommended by the SCPIconsortium and following other Spirent AE simulators and noise generators and to simplify programming, the DLS 410A uses the following tree structures:

DLS 410A (both DLS 411A and DLS 412A)

:SETting:CHANnel

:STAte <Normal|Bypass|Disconnect>:System

:Reset:Error?:Calibration

:date?:expiry?

:SLotID?:SetM1<String>:SetM2<String>:SetM3<String>

DLS 411A Only

:SourceA:Noise <On|Off>

DLS 412A Only

:SourceB:Noise <On|Off>

Each section of the command may be sent in the full or the truncated form (indicated in upper case). The command itself may be sent in upper or lower case form.

The DLS 410A will round any number to the nearest number permitted by the resolution of the parameter.

Section 5.3 "Command Syntax" and Section 5.4 "DEVICE DEPENDENT COMMAND SET" give more information on the data format and the command syntax.

Settings for all of these commands are stored in non-volatile RAM. When the unit is powered up, their val-ues are restored to the same state as before the unit was powered down.

When shipped, the default setting for the noise injection of both sides is off.

The following sections describe the command settings in more detail.

5.4.1 System Check Commands

5.4.1.1 :System:Error?

This command is read only and returns the overall status of the unit. The status is generated during boot up, and is also indicated by the Power LED.

If the return string is "0", it means that there is no error. If the return string is "1", it means that at least one card in the system is of the wrong type for this model of simulator.

To determine which card is in error, use the :System:SlotID? command.

Page 53: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 5-7

7104000548-10/04-4

5.4.1.2 :System:SlotID?

This command is read only and returns the overall status of every card installed in the system.

The return string represents four bytes in hex format. This translates to one bit per card. If the bit corre-sponding to the card is "0", then the card is OK. If the bit is "1" then the card has the wrong ID.

In binary format, the bits are labelled D1 to D32. D1 represents card 1, D28 represents card 28 and D29 rep-resents the front end car. D30 to D32 are always "0".

Example: If the return string is "C0000000", it means that the ID is wrong for the cards in slots 1 and 2.

5.4.1.3 :System:Calibration:date?

This command is read only and returns the last date the unit was calibrated. The string is a maximum of 25 characters.

5.4.1.4 :System:Calibration:expiry?

This command is read only and returns the date at which the unit should be next calibrated. The string is a maximum of 25 characters.

5.4.1.5 :System:Calibration:date <date>

This command enters the value of the last calibration date. When shipped from the factory, this value is set to ’0’ by default. For new units, the purchase date of the unit should be entered.

5.4.1.6 :System:Calibration:expiry <date>

This command enters the value of the calibration epiry date. When shipped from the factory, this value is set to ’0’ by default. For new units, one year from the purchase date of the unit should be entered.

5.4.2 :SETting:CHANel:State<Normal|Bypass|Disconnect>

Setting the channel state to Bypass will bypass all line simulator cards in the DLS 410A chassis. Setting the channel state to disconnect replaces the loop with an open circuit.

For example, to set the state to bypass, send:

:SET:CHAN:STATE BypassYou should take care not to interrupt the completion of this command. Using the *WAI or the *OPC com-mand ensures that this command is complete before issuing a subsequent command. See Section 5.5 "Com-mon Command Set" for more details on the *WAI or *OPC command.

5.4.3 :SETM1<String>/SETM2<String>/SETM3<String>

The :SetM1/M2/M3 command will send the M1, M2 or M3 variable as required to set the simulated loop. ie:

:SetM1 00001F01F00001F01F01FC7341C42F01F00001F01F00001F01F000

:SetM2 80001F01F00001F01F02F03F81F82F01F00002F01F00002F01F800

:SetM3 00001F01F00001F01F02F03F81F82F01F00002F01F00002F01F000 Please ensure *ESR? follows every command for error checking. :SETM3 should be synchronized for its operation complete. After issuing the :SETM3 command, the *OPC? should be sent to ensure the operation is complete. It may take up to 2 seconds for the :SETM3 command to complete.

Page 54: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 5-8 - Spirent Communications

7104000548-10/04-4

Note that each chassis has its own set of M1, M2 and M3 values.

The M1, M2 and M3 variable is a null terminated 54-character string. There are 3 methods that can be used to find the M1, M2 and M3 values for both chassis 1 and chassis 2, "M" values are required to set a particu-lar loop:

1) Reference a csv file that contains a listing of M1,M2 and M3 values. This method can only be used for standard-based loops. See Section 5.4.3.7 "Steps For Using a .CSV File to Determine M1, M2 and M3 Values" for more information.

2) Use the DLS Converter API which returns the M1,M2 and M3 values. This method can be used for both standard-based and must be used for custom loop compensated loops. Custom compensated loop settings have millions of possible loop segment configurations, therefore using the DLS Con-verter API is the only option, See Section 5.4.3.8 "Using the DLS 410A Converter API to Deter-mine M1, M2 and M3 Values", for more information.

3) Copy the M1, M2 and M3 values as they appear in the log window of the DLS 410A GUI. This method can be used for both standard based loops and custom loops. Also, this method will display compensated M1,M2 and M3 variables if a compensated loop mode option has been selected from the GUI.

5.4.3.7 Steps For Using a .CSV File to Determine M1, M2 and M3 Values

The steps to determine the M1,M2 and M3 values using a .csv (either the factory-shipped file, or a DLS Compensation results file) are described as follows. Note that this method can only be used to set standard-length loops. All files used are in .csv format, for easy parsing and extraction of M1,M2 and M3 values.

1) Reference the file called DLS410A_LoopLength_setting.csv. This file can be found in the DLS 410A working directory.

This file gives the loop ID number for all of the standard loops on the 410A as shown below. It also gives information about the lengths of line segment L1, and L2 through L6 (if used).

Figure 5.1 DLS410A_LoopLength_setting.csv File

Find the Loop ID number for the loop you wish to set.

Reference the file that contains the M1, M2 and M3 values that need to be sent to each chassis. There are two types of settings: Factory settings and Compensated settings.

Page 55: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 5-9

7104000548-10/04-4

Factory Settings: To use factory settings, reference the file Dls410ACommand.csv (see Fig-ure 5.2). This file can be found in the working directory of the DLS 410A software.

Figure 5.2 Dls410ACommand.csv File

Compensated Settings Using System Compensation Results from DLS 410A v 2.1 Soft-ware: To use compensated settings derived from running the Standards-based loops com-pensation, reference the system compensation result file. This file by default is stored in the working directory of the DLS 410A, in the ’comp’ sub folder.

This file is structured identically to the Dls410ACommand.csv file. Note that this file contains the M1, M2 and M3 values for 208 standard loops only, the custom .csv file has thousands of entries. For more information on compensation, please refer to Section 4 "PERFORMING SYSTEM COMPENSATION TESTS".

2) Using the loop ID number from step 1), and the csv file opened in step 2), find the values of M1, M2 and M3 that should be sent to chassis 1 (the DLS 411A) and chassis 2 (the DLS 412A). For example, the loop ID number for a straight loop of 0.5 kft is 1, so the values of M1, M2 and M3 that need to be sent are: DLS 411A (chassis 1) :SetM1 00001F01F00001F01F01FC7341C42F01F00001F01F00001F01F000

:SetM2 80001F01F00001F01F02F03F81F82F01F00002F01F00002F01F800

:SetM3 00001F01F00001F01F02F03F81F82F01F00002F01F00002F01F000

DLS 412A (chassis 2)

:SetM1 00001F01F00001F01F01F00001F01F01F00001F01F00001F01F000 :SetM2 80001F01F00001F01F02F00001F02F01F00002F01F00002F01F800

:SetM3 00001F01F00001F01F02F00001F02F01F00002F01F00002F01F000

5.4.3.8 Using the DLS 410A Converter API to Determine M1, M2 and M3 Values

The M1, M2 and M3 values may also be determind by using the default DLS 410A Converter API that is included with the DLS 410A software. Note that this will either be factory settings or based upon the results from the "custom loops"compensation depending on if the user calls: [DLS 410converter_loadcompensationdata] function located within the API. Custom compensation data files can be loaded such that the generated "M" strings will contain the compensated settings . The only way to get compensated M1, M2 and M3 values is to use the method described in Section 5.4.3.7 "Steps For Using a .CSV File to Determine M1, M2 and M3 Values"

Page 56: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 5-10 - Spirent Communications

7104000548-10/04-4

The components of the Convert API package are installed in the C:\Program Files\Spirent Communica-tions\DLS 410A directory when the DLS 410A software is installed.

1) Dls410ConverterApi.lib. This compile-time file contains the link library. See below for the con-tents of this file.

2) dls410ConverterApi.h. This compile-time file contains the interface description to the Dls410Converter module.

3) Dls410ConverterApi.dll This run-time file contains the release version of the library. 4) Readme.txt. This file contains important information about the API.

Note: The length settings passed to the 410 converter convert loop definition function are constrained to the same "L" values available in the GUI.

DLS 410A ConverterApi.h

// dls410ConverterApi.h: interface for the Cdls410Converter class.////////////////////////////////////////////////////////////////////////

#if !defined(AFX_Dls410ConverterApi_H__INCLUDED_)#define AFX_Dls410ConverterApi_H__INCLUDED_

#if _MSC_VER > 1000#pragma once#endif // _MSC_VER > 1000

#if defined(DLS410_HAS_EXPORTS)#define DLS410LIB __declspec(dllexport)

#else #define DLS410LIB #endif

#define DLS_410_MAX_LOOPS 6#define DLS_410_COMMAND_SIZE 55 // 54 characters + null character

/*** These error codes are hopefully self explanatory.*/#define DLS_410_Error_Initialization_failed -100#define DLS_410_Error_Incorrect_Loop_type -101#define DLS_410_Error_Incorrect_loop_length -102#define DLS_410_Error_Invalid_pointer -103

#define DLS_410_Error_Conversion_failed -104

#ifdef __cplusplusextern "C" {#endif /* __cplusplus */

enum Dls410LoopTypes{ Dls410_Loop_Straight=1, Dls410_Loop_Bridgedtap,

Page 57: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 5-11

7104000548-10/04-4

Dls410_Loop_Ansi13, Dls410_Loop_Csa4, Dls410_Loop_Straight_G996_1, Dls410_Loop_Bridgedtap_G996_1, Dls410_Loop_Ansi13_G996_1, Dls410_Loop_Csa4_G996_1, DLS410_Loop_end};

typedef struct{ char cmdM1[DLS_410_COMMAND_SIZE]; char cmdM2[DLS_410_COMMAND_SIZE]; char cmdM3[DLS_410_COMMAND_SIZE]; } Dls410CmdBuffer;

typedef struct{ /* ** Dls410LoopTypes enumerates the recognized loop types. */ UINT loopType;

/* ** Each command will be stored in one of the buffers. The first buffer ** is meant for the Dls411A chassis while the other is meant for the ** Dls412A chassis. All data previously stored in these buffers will be ** overwritten. */ Dls410CmdBuffer cmdBufferArray[2]; /* ** This variable contains the lengths for each loop. It is important to ** make sure all pertinent lengths are properly set. */ int loopLengthArray[DLS_410_MAX_LOOPS];

} Dls410LoopDefinition;

/*** This method takes a custom compensation file name and loads it into the converter.** Pass a NULL string in order to restore the default settings.** All subsequent calls to Dls410Converter_convertLoopDefinition will use the last loaded** compensation data. (The M string values generated are based upon the loaded file.)**** The user should take care to ensure that the correct file is used for a given system.**** Function returns 0 if successful.*/DLS410LIB int WINAPI Dls410Converter_loadCompensationData(const char* cszFileName);**** The user should take care to ensure that the correct file is used for a given system.**

Page 58: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 5-12 - Spirent Communications

7104000548-10/04-4

** Function returns 0 if successful.*/DLS410LIB int WINAPI Dls410Converter_loadCompensationData(const char* cszFileName);

/*** This method takes all settings at once and returns 0 on succesfull completion** or one of the errors listed above.*/DLS410LIB int WINAPI Dls410Converter_convertLoopDefinition(Dls410LoopDefinition* loopSetup);

#ifdef __cplusplus}#endif /* __cplusplus */

#endif // !defined(AFX_Dls410ConverterApi_H__INCLUDED_)

DLS 410A Converter API Example

The following procedure is an example of how to use the converter API to get the M1, M2 and M3 vari-ables that must be sent to both the DLS 411A chassis and DLS 412A chassis to set a straight loop of 9000 ft.

int testConverter()

{

const char* file = "C:\\Program Files\\Spirent Communications\\DLS 410A\\cust\\DLS410A_DL43669_DL43667_2004_10_04-18_22_32-Cust.csv";

/* The following takes a custom compensation file name and loads it into the converter. Pass a NULL string in order to restore the default settings. */

int err = Dls410Converter_loadCompensationData(file);

if (err!=0)

return err;

/* All calls to Dls410Converter_convertLoopDefinition use the last loaded compensation data. */

Dls410LoopDefinition loopDef;

/*declare variable loopDef as type Dls410LoopDefinition*/

loopDef.loopType=Dls410_Loop_Straight;

/*set loop type to straight loop (as per T1.417 cable model), other loop types are

Dls410_Loop_Bridgedtap (as per T1.417 cable model)

Dls410_Loop_Ansi13 (as per T1.417 cable model)

Dls410_Loop_Csa4 (as per T1.417 cable model )

Dls410_Loop_Straight_G996_1 (as per G.996.1 cable model)

Page 59: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 5-13

7104000548-10/04-4

Dls410_Loop_Bridgedtap_G996_1, (as per G.996.1 cable model)

Dls410_Loop_Ansi13_G996_1, (as per G.996.1 cable model)

Dls410_Loop_Csa4_G996_1 (as per G.996.1 cable model) */

loopDef.loopLengthArray[0]=9000;

/*set length of segment L1 to 9000 ft. */

int err = Dls410Converter_convertLoopDefinition(&loopDef);

/*check that length and loop type settings are valid*/

if(err!=0)

return err;

/*Commands to send to DLS 411A*/

printf("setM1 %s\n",loopDef.cmdBufferArray[0].cmdM1);

printf("setM2 %s\n",loopDef.cmdBufferArray[0].cmdM2);

printf("setM3 %s\n",loopDef.cmdBufferArray[0].cmdM3);

/*Commands to send to DLS 412A*/

printf("setM1 %s\n",loopDef.cmdBufferArray[1].cmdM1);

printf("setM2 %s\n",loopDef.cmdBufferArray[1].cmdM2);

printf("setM3 %s\n",loopDef.cmdBufferArray[1].cmdM3);

loopDef.loopType= Dls410_Loop_Csa4.;

/*change loop type to Csa4. Loop segments L1-L5 will be set to standard lengths * /

loopDef.loopLengthArray[0]=550; /*set length of segment L1 to 550 ft. */

loopDef.loopLengthArray[1]=400; /*set length of segment L2 to 400 ft. */

loopDef.loopLengthArray[2]=6250; /*set length of segment L3 to 6250 ft. */

loopDef.loopLengthArray[3]=800; /*set length of segment L4 to 800 ft. */

loopDef.loopLengthArray[4]=800; /*set length of segment L5 to 800 ft. */

int err = Dls410Converter_convertLoopDefinition(&loopDef);

/*check that length and loop type settings are valid*/

if(err!=0)

return err;

/*Commands to send to DLS 411A*/

printf("setM1 %s\n",loopDef.cmdBufferArray[0].cmdM1);

printf("setM2 %s\n",loopDef.cmdBufferArray[0].cmdM2);

printf("setM3 %s\n",loopDef.cmdBufferArray[0].cmdM3);

/*Commands to send to DLS 412A*/

Page 60: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 5-14 - Spirent Communications

7104000548-10/04-4

printf("setM1 %s\n",loopDef.cmdBufferArray[1].cmdM1);

printf("setM2 %s\n",loopDef.cmdBufferArray[1].cmdM2);

printf("setM3 %s\n",loopDef.cmdBufferArray[1].cmdM3);

return 0; }

5.4.4 :SourceA:Noise <ON|OFF> (DLS 411A only)

The unit has one switched port NA that can be connected to a noise generation system. Setting the Source A to ON connects the analog device (connected to the port labelled NA) in parallel with the DLS 411A line simulator cards. Setting Source A to OFF disconnects the NA port.

For example, to switch the NA port ON, send:

:SourceA:Noise ON

Users should take care not to interrupt the completion of this command. Using the *WAI or the *OPC com-mand can ensure that this command is complete before issuing a subsequent command. See Section 5.5 "Common Command Set" for more details on the *WAI or *OPC command.

5.4.5 :SourceB:Noise <ON|OFF> (DLS 412A only)

The unit has one switched port NB that can be connected to a noise generation system. Setting the Source B to ON connects the analog device (connected to the port labelled NB) in parallel with the DLS 412A line simulator cards. Setting Source B to OFF disconnects the NB port.

For example, to switch the NB port ON, send:

:SourceB:Noise ON

Users should take care not to interrupt the completion of this command. Using the *WAI or the *OPC com-mand can ensure that this command is complete before issuing a subsequent command. See Section 5.5 "Common Command Set" for more details on the *WAI or *OPC command.

5.4.6 :System:Reset

This command causes the system to reset in the same manner as the power-down, power-up.

For example, to reset the unit, send:

:System:Reset

5.5 Common Command SetAs specified in the IEEE 488.2 standard, a number of common commands are required to set up and control of the standard functions of remote-controlled devices. They can be used with both the IEEE 488 and the RS–232 interfaces. These common commands are as follows:

*CLS Clear Status CommandType: Status commandFunction: Clears the Event Status Register (ESR). Clearing the Event Status Register will also clear

ESB, the bit 5 of the Status Byte Register (STB). It has no effect on the output queue (bit 4 of the STB).

Page 61: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 5-15

7104000548-10/04-4

*ESE <NRf> Event Status EnableType: Status commandFunction: Sets the Event Status Enable Register (ESER) using an integer value from 0 to 255, repre-

senting a sum of the bits in the following bit map:

Bits 7 to 0 have values of 128, 64, 32, 16, 8, 4, 2 and 1, respectively. For example, if bits 3 and 5 are set then the integer value is 40 (8+32).

The ESER masks which bits will be enabled in the Event Status Register (ESR).

On power-on, the register is cleared.

*ESE? Event Status Enable QueryType: Status commandFunction: An integer value between 0 and 255 representing the value of the Event Status Enable

Register (ESER) is placed in the output queue. The possible values are described in the *ESE command section.

*ESR? Event Status Register QueryType: Status commandFunction: An integer value between 0 and 255 representing the value of the Event Status Register

(ESR) is placed in the output queue. Once the value is placed in the output queue, the reg-ister is cleared. The command will turn the REMOTE LED green if the LED was red. The possible values are described in the *ESE command section.

*IDN? Identification QueryType: System commandFunction: Returns the ID of the unit. Upon receiving this command, the DLS 410A will put the fol-

lowing string into the output queue:

SPIRENT COMM INC,<unit ID>,<SN>,<Ver>

where:<unit ID> is DLS 410A,<SN> is the serial number of the unit (i.e.: DL 41XXX), <Ver> is the revision level of the control firmware (always 3 digits)

*OPC Operation CompleteType: Synchronization commandFunction: Indicates to the controller when the current operation is complete. This command will

cause the DLS 410A to set bit 0 in the Event Status Register (ESR) when all pending oper-ations are completed. The bit is read with the *ESR? command, which also clear the bit. Communication can proceed as normal after this command, but be prepared to receive SRQ at any time.

Page 62: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 5-16 - Spirent Communications

7104000548-10/04-4

*OPC? Operation Complete QueryType: Synchronization commandFunction: Indicates when the current operation is complete. This will cause the DLS 410A to put an

ASCII 1 (decimal 49, hex 31) in the output queue when the current operation is complete. Communication can proceed as normal after this command, but be prepared to receive the “1” at any time.

*RST ResetType: Internal commandFunction: IEEE 488.2 level 3 reset. This command cancel any pending *OPC operation. It will not

affect the output buffer or other system settings of the unit. Note that this is NOT equiva-lent to the power-up reset and the IEEE 488 “Device Clear”.

*SRE <NRf> Service Request EnableType: Status commandFunction: Sets the Service Request Enable Register (SRER). An integer value indicates which serv-

ice is enabled, with the following bit map:

Bits 7 to 0 have values of 128, 64, 32, 16, 8, 4, 2 and 1, respectively. For example, if bits 4 and 5 are set then the integer value is 48 (16+32).

Note that if both MAV and ESB are disabled, then the bits MSS and RQS and the line SRQ are never going to be raised.

On power-on, this register is cleared.

*SRE? Service Request Enable QueryType: Status commandFunction: An integer value representing the value of the Service Request Enable Register is placed

in the output queue. The possible values are listed in the *SRE command section.

*STB? Status Byte QueryType: Status commandFunction: The value of the Status Byte Register is put into the output queue. Contrary to the

“*ESR?” command, this register is not cleared by reading it. The register will be zero only

Page 63: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 5-17

7104000548-10/04-4

when all its related structures are cleared, namely the Event Status Register (ESR) and the output queue.

Bits 7 to 0 have values of 128, 64, 32, 16, 8, 4, 2 and 1, respectively. For example, if bits 3 and 5 are set then the integer value is 40 (8+32).

Note that bit 6 is MSS, which does not necessarily have the same value as RQS.

*TST? Self-Test QueryType: Internal commandFunction: Returns the results of the self-test done at power up. The number returned has the follow-

ing bit map:

Passed Flash memory test

Bits 7 to 0 have values of 128, 64, 32, 16, 8, 4, 2 and 1, respectively. For example, if bits 0 and 1 are set then the integer value is 3 (1+2).

*WAI Wait to continueType: Synchronization commandFunction: Used to delay execution of commands. The DLS 410A will ensure that all commands

received before “*WAI” are completed before processing any new commands. This means that all further communication with the DLS 410A will be frozen until all pending opera-tions are completed.

5.6 Status Reporting

There are two registers that record and report the system status, the Status Byte Register (STB), and the Event Status Register (ESR).

Page 64: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 5-18 - Spirent Communications

7104000548-10/04-4

For both registers there are three basic commands: one to read the register, one to set the enabling bits, and one to read the enabling bits.

Table 4-3:Byte Register Commands

Status Byte Register Event Status Register

Read Register *STB? *ESR?

Set Enabling Bits *SRE <NRf>

*ESE <NRf>

Read Enabling Bits *SRE? *ESE?

Where <NRf> is the new value of the register.

5.6.1 Status Byte Register (STB)

The bits of this register are mapped as follows:

bit 4: MAV (Message Available Bit)

Indicates that the Output Queue is not empty. If MAV goes high and is enabled then MSS goes high.

bit 5: ESB (Event Status Bit)

It indicates that at least one bit of the Event Status Register is non zero and enabled. If ESB goes high and is enabled then MSS goes high.

bit 6: MSS/RQS (Master Summary Status/Request Service)

MSS is raised when either MAV or ESB are raised and enabled. When the status of MSS changes, the whole Status Byte Register is copied into the Status Byte of the GPIB con-troller, where bit 6 is called RQS. When RQS goes high so does the SRQ line, and in response to an IEEE 488.1 Serial Poll command, both are cleared.

RQS and SRQ are defined by the IEEE 488.1 standard and are hardware related. MSS summarizes all the status bits of the DLS 410A, as defined by the IEEE 488.2 standard.

bits 7, 3, 2, 1,and 0

These bits are not used by the DLS 410A.

5.6.2 Event Status Register (ESR)

The Event Status Register monitors events within the system and reports on those enabled. It records transi-tory events as well. The DLS 410A implements only the IEEE 488.2 Standard Event Status Register (ESR). It is defined as:

bit 0 Operation Complete. This bit is set in response to the *OPC command when the current operation is complete.

bit 1 Request Control. The DLS 410A does not have the ability to control the IEEE bus, and so this bit is always 0.

Page 65: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 5-19

7104000548-10/04-4

bit 2 Query Error. There was an attempt to read an empty output queue or there was an output queue overflow. (maximum output queue capacity is 75 bytes).

bit 3 Device Dependent Error. Not used, so this bit is always 0.

bit 4 Execution Error. The data associated with a command was out of range.

bit 5 Command Error. Either a syntax error (order of command words) or a semantic error (spelling of command words) has occurred.

bit 6 User Request. Indicates that the user has activated a Device Defined control through the front panel. Not used, so this bit is always 0.

bit 7 Power on. This bit is set when the DLS 410A is turn on. Sending *ESR? clears the bit and stays clear until the power is turned on again.

The setting of the Event Status Register can be read with the Event Status Register query command (*ESR?). This will put the value of the register in the output queue, AND will clear the register.

5.7 DLS 410A SynchronizationThe program controlling the DLS 410A can use three different commands to synchronize with the DLS 410A: *OPC, *OPC? and *WAI. Following are the main differences:

Table 4-4: Synchronization Commands

Set Operation

Complete bit when Done

Return “1” when

operation complete

Raise SRQ when

operation complete

Block comm. with

the DLS 410A

Required Enable Bit(s)

*OPC Yes No Yes1

No Operation Com-plete, ESB

*OPC? No Yes Yes2

No MAV

*WAI No No No Yes none

1. if “Operation Complete” and ESB are enabled2. if MAV is enabled

The main difference between OPC and WAI is that WAI will block any further communication with the DLS 410A until all pending operations are completed.

The main difference between *OPC and *OPC? is that *OPC sets the “Operation Complete” bit, and *OPC? will return an ASCII “1” when all pending operations are completed.

Make sure that all the required enable bits are set.

When using *OPC or *OPC?, the program controlling the DLS 410A can determine when the operation is completed by waiting for SRQ, or by reading the status byte with the serial poll or with *STB? (if corre-sponding bits are enabled).

Page 66: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 5-20 - Spirent Communications

7104000548-10/04-4

If the program uses the *OPC? command and then sends more queries, the program must be ready to receive the “1” concatenated to other responses at any time. When using *WAI, the communication time out should be set long enough to avoid losing data.

Page 67: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 6-1

7104000548-10/04-4

6. REFERENCES

• IEEE 488.1-1987, IEEE Standard Digital Interface for Programmable Instrumentation (The Institute of Electrical and Electronics Engineers, Inc. 345 East 47th Street, New York, NY 10017-2394, USA)

• IEEE 488.2-1992, IEEE Standard Codes, Formats, Protocols, and Common Commands (The Institute of Electrical and Electronics Engineers, Inc. 345 East 47th Street, New York, NY 10017-2394, USA)

• SCPI Standard Commands for Programmable Instruments, available from some interface controller manufacturers (SCPI Consortium, 8380 Hercules Drive, Suite P.S., La Mesa, CA 91942, Phone: (619) 697-8790, Fax: (619) 697-5955)

• ITU-T Contributions during ITU-T SG15 Q4 rapporteur meeting in Durango, Colorado, USA (Interna-tional Telecommunication Union, Place des Nations, CH1211 Geneva 20, Switzerland)

• DC-048R2 Contributions to ITU-T SG15 Q4 (Spirent Communications, 750 Palladium Drive, Ottawa, Ontario, Canada K2V 1C7)

• ITU-T Recommendation G.996.1 (International Telecommunication Union, Place des Nations, CH1211 Geneva 20, Switzerland)

• ITU-T Recommendation G.992.3 (International Telecommunication Union, Place des Nations, CH1211 Geneva 20, Switzerland)

• ITU-T Draft Recommendation G.992.5, ADSL2plus specification (International Telecommunication Union, Place des Nations, CH1211 Geneva 20, Switzerland)

• ANSI T1.417, Spectrum Management for Loop Transmissions System (American National Standards Institute, 11 West 42nd Street, New York, NY 10036, USA)

• DSL Forum TR-048, ADSL Interoperability Test Plan (DSL Forum, 39355 California Street, Suite 307 Fremont, CA 94538)

• DSL Forum TR-067, ADSL Interoperability Test Plan (DSL Forum, 39355 California Street, Suite 307 Fremont, CA 94538

Page 68: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 6-2 - Spirent Communications

7104000548-10/04-4

Page 69: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 7-1

7104000548-10/04-4

7. CUSTOMER SUPPORT

7.1 Customer Service Contact Information

For all North American customers, please direct any questions or concerns regarding the operation of a pur-chased unit, to the Spirent Communications Customer Service team by one of the following methods:

Direct Line: 613-592-7301

Toll free at:800-465-1796

Fax at: 613-592-0522

E-mail at: [email protected].

All other customers should check the ae.spirentcom.com web site for the contact information of the nearest Customer Service center or contact the main Spirent Communications service center for assistance (contact information is listed above).

For product information and updates, please visit the Spirent Communications web site at:

http://ae.spirentcom.com

For product manuals, software updates and more information, please visit the customer extranet at:

http://ae.spirentcom.com/extranet.htm.

7.2 Protecting Your Investment

Spirent Communications is committed to providing the highest quality products and customer support possi-ble. An annual calibration is required to ensure that your unit is operating properly.

Spirent Communications is pleased to offer two cost effective optional service programs. Each of these pro-grams is designed to improve the ease and efficiency of servicing Spirent Communications test equipment.

Extended Warranty

Spirent Communications' Extended Warranty gives two years in addition to the original one-year manufac-turer’s warranty. Under the warranty agreement, Spirent Communications repairs any covered product that needs service during the warranty period. At the time of repair, any required firm ware and/or software upgrades are installed free of charge and if required as part of the repair, the unit receives a complete calibra-tion. Spirent Communications also provides return shipment of any unit covered under warranty at Spirent Communications’s cost.

The Extended Warranty gives:

• Extension of the original one-year limited warranty by two years (giving a total warranty coverage of three years).

• Required firm ware and software upgrades installed free at time of repair.

• If required because of a repair, free calibration due to repair during the coverage period.

• Prepaid, return shipment of repaired products worldwide.

Page 70: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 7-2 - Spirent Communications

7104000548-10/04-4

Spirent Communications' Extended Warranty can be purchased at any time up until the expiration of the original one-year manufacturer's warranty.

Three-Year Calibration Agreement

Spirent Communications’ three-year calibration agreement gives the opportunity to invest in a yearly cali-bration for three years at a significant cost saving, ensuring optimum product performance.

Specific Spirent Communications products are shipped with a National Institute of Standards and Technol-ogy (N.I.S.T.) traceable calibration that expires one year from the original ship date. With ISO-9000 and other manufacturer specific metrology requirements, timely calibrations become critical to your operations. Spirent Communications sends out an e-mail reminder when the next calibration is due. A report containing all calibration data is shipped with the product.

The Spirent Communications’s three-year calibration agreement gives:

• Three yearly N.I.S.T traceable calibrations (one per year).

• Notification from Spirent Communications when calibration is due.

• Calibration data report.

• Prepaid return shipment of calibrated unit worldwide.

• The Spirent Communications’ three-year calibration agreement may be purchased at any time.

Please contact Spirent Communications Customer Service for more information on these programs, or visit us on the web at ae.spirentcom.com.

Page 71: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 8-1

7104000548-10/04-4

8. WARRANTY

Spirent Communications warrants all equipment bearing its nameplate to be free from defects in workman-ship and materials, during normal use and service, for a period of twelve (12) months from the date of ship-ment.

In the event that a defect in any such equipment arises within the warranty period, it shall be the responsibil-ity of the customer to return the equipment by prepaid transportation to a Spirent Communications service centre prior to the expiration of the warranty period for the purpose of allowing Spirent Communications to inspect and repair the equipment.

If inspection by Spirent Communications discloses a defect in workmanship or material it shall, at its option, repair or replace the equipment without cost to the customer and return it to the customer by the least expen-sive mode of transportation, the cost of which shall be prepaid by Spirent Communications.

In no event shall this warranty apply to equipment which has been modified without the written authoriza-tion of Spirent Communications, or which has been subjected to abuse, neglect, accident or improper appli-cation. If inspection by Spirent Communications discloses that the repairs required are not covered under this warranty, the regular repair charges shall apply to any repairs made to the equipment.

For international customers, please contact your local Spirent Communications sales representative or check the ae.spirentcom.com web site for the contact information of the nearest service center.

In North America, if warranty service becomes necessary, the customer must contact Spirent Communica-tions to obtain a return authorization number and shipping instructions:

Spirent Communications750 Palladium Drive

Ottawa, Ontario, CanadaK2V 1C7

Customer Service Direct Line: 613-592-7301Fax: 613-592-0522

Toll Free: [email protected]

This warranty constitutes the only warranty applicable to the equipment sold by Spirent Communications, and no other warranty or condition, statutory or otherwise, expressed or implied, shall be imposed upon Spirent Communications nor shall any representation made by any person, including a representation by a representative or agent of Spirent Communications, be effective to extend the warranty coverage provided herein.

In no event (including, but not limited to the negligence of Spirent Communications, its agents or employ-ees) shall Spirent Communications be liable for special consequential damages or damages arising from the loss of use of the equipment, and on the expiration of the warranty period all liability of Spirent Communi-cations whatsoever in connection with the equipment shall terminate.

Page 72: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 8-2 - Spirent Communications

7104000548-10/04-4

Page 73: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 9-1

7104000548-10/04-4

9. SHIPPING THE UNIT

To prepare the unit for shipment, turn the power off, disconnect all cables (including the power cable) and pack the simulators in their original cartons. Do not place any cables or accessories directly against the front panel as this may scratch the surface of the unit. It is highly recommended that all shipments are marked with labels indicating that the contents are fragile.

If sending a unit back to the factory, ensure that the Return Material Authorization (RMA) number given by the Spirent Communications Customer Service department is shown on the outside.

The RMA number is mandatory and must be obtained from a Spirent Communications Customer Service center before shipping the unit (see Section 7 "CUSTOMER SUPPORT" for details on how to contact the nearest Spirent Communications Customer Service center).

Page 74: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 9-2 - Spirent Communications

7104000548-10/04-4

Page 75: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 10-1

7104000548-10/04-4

10. SPECIFICATIONS

10.1 Wireline Simulator SpecificationsTechnology Cable & bridged tap simulation using passive circuits

Types of Wire 24 AWG and 26 AWG selectable as per ANSI T1.417 and ITU-T G.996.1 Cable models

Number of Conductors Two

Standard ITU-T Draft Recommendation G.992.5 ADSL2plus specification

ITU-T Contributions during ITU-T SG15 Q4

DC-048R2 Contributions to ITU-T SG15 Q4

ITU-T Draft Recommendation G.996.1

ITU-T G.992.3

Simulated Loops Straight Loop or Straight Loop with Bridged Tap, ANSI 13 and CSA 4 topologies, each segment of line being variable independently

Bandwidth DC to 4.5 MHz continuous frequency response

Attenuation Typically, max. MAE <0.5dB for attenuation up to 90 dB, after compen-sation.

Impedance Typically +/- 5%

Delay Typically +/- 5%

Average Background Noise Typically < - 150 dBm/Hz

DC Resistance of the Loop Typically +/- 10%

DC Rating ± 200 V between tip and ring, tip and ground, ring and ground

and 125 mA (150 mA peak)

Measurement Termination 100 Ohm

Power Supply 140 VA max: 100-240 VAC (50-60 Hz)

Fuses Type ‘T’ 2A/250V Slow Blow (2 required, 5mm x 20mm)

Environmental:

Operating Temperature +10ºC to +40ºC (50ºF to 104ºF)

Storage Temperature -20° C to +70° C (-4° F to 158° F)

Humidity 90% (non-condensing) max.

Mechanical

Weight per chassis 28 kg. max.

Dimensions per chassis 194 mm x 452 mm x 494 mm (H x W x D)

(7.6" x 17.8" x 19.4")

Page 76: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 10-2 - Spirent Communications

7104000548-10/04-4

IEEE 488 Remote Control

RS-232 Remote Control

System

• DLS 411A/DLS 412A chassis for DLS 410A configuration

• 1 Control Software

• 1 DLS 410A Operating Manual on CD

• 1 Power cord (per chassis)

• 2 fuses (per chassis)

• 1 RJ-45 blue unshielded twisted pair (UTP) inter-connection cable

• 1 RS–232C inter-connection cable (per chassis)

• 1 IEEE 488 inter-connection cable (per chassis)

• 1 IEEE reverser (per chassis)

Associated Products

• National Instruments IEEE 488 card (for the controlling PC)

• DLS 5200AP Noise Generation System (external)

10.2 Operating Conditions

In order for the unit to operate correctly and safely, it must be adequately ventilated. The DLS 410A ADSL 2++ Wireline Simulator contains ventilation holes for cooling. Do not install the equipment in any location where the ventilation is blocked. For optimum performance, the equipment must be operated in a location that provides at least 10 mm of clearance from the ventilation holes. Blocking the air circulation around the equipment may cause the equipment to overheat, compromising its reliability.

Page 77: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 11-1

7104000548-10/04-4

11. SAFETY

11.1 Information

11.1.1 Protective Grounding (Earthing)

This unit consists of an exposed metal chassis that must connect directly to a ground (earth) via a protective grounding conductor in the power cord. The symbol used to indicate a protective grounding conductor ter-minal in the equipment is shown in this section under “symbols”.

11.1.2 Before Operating the Unit

• Inspect the equipment for any signs of damage, and read this manual thoroughly.

• Become familiar with all safety symbols and instructions in this manual to ensure that the equipment is used and maintained safely.

WARNING: To avoid risk of injury or death, ALWAYS observe the following precautions before oper-ating the unit:

• Use only a power supply cord with a protective grounding terminal.

• Connect the power supply cord only to a power outlet equipped with a protective earth contact. Never connect to an extension cord that is not equipped with this feature.

• Do not wilfully interrupt the protective earth connection.

• The protective conductor terminal must be attached to the mains supply earth.

CAUTION: When lifting or moving the unit, be careful not to apply any pressure to the plastic grid which is located on the bottom of the chassis, toward the front right corner. Lift the chas-sis by gripping it on both sides at the bottom, ensuring not to touch the plastic grid.

11.1.3 Power Supply Requirements

The unit can operate from any single phase AC power source that supplies between 100V and 240V (±10%) at a frequency range of 50 Hz to 60 Hz.

WARNING: To avoid electrical shock, do not operate the equipment if it shows any sign of damage to any portion of its exterior surface, such as the outer casting or panels.

11.1.4 Fuses

The fuse type used is specified in Chapter 10 "SPECIFICATIONS".

11.1.5 Connections to a Power Supply

In accordance with international safety standards, the unit uses a three-wire power supply cord. When con-nected to an appropriate AC power receptacle, this cord grounds the equipment chassis.

Page 78: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 11-2 - Spirent Communications

7104000548-10/04-4

11.1.6 Operating Environment

To prevent potential fire or shock hazard, do not expose the equipment to any source of excessive moisture.

11.1.7 Class of Equipment

The simulator consists of an exposed metal chassis that is connected directly to earth via the power supply cord. In accordance with HARMONIZED EUROPEAN STANDARD EN 61010-1:1993, it is classified as Safety Class I equipment.

WARNING: This is a class A product. In a domestic environment this product may cause radio interfer-ence in which case the user may be required to take adequate measures.

11.2 Instructions

The following safety instructions must be observed whenever the unit is operated, serviced or repaired. Fail-ing to comply with any of these instructions or with any precaution or warning contained in the Operating Manual is in direct violation of the standards of design, manufacture and intended use of the equipment.

Spirent AE assumes no liability for the customer’s failure to comply with any of these requirements.

11.2.1 Before Operating the Unit• Inspect the equipment for any signs of damage, and read the Operating Manual thoroughly.

• Install the equipment as specified in the relevant section of this manual.

• Ensure that the equipment and any devices or cords connected to it are properly grounded.

WARNING: The maximum input to the unit should not exceed +37 dBm, and should not exceed +/- 200 Vdc and 125 mA.

11.2.2 Operating the Unit

• Do not operate the equipment when its covers or panels have been removed.

• Do not interrupt the protective grounding connection. Any such action can lead to a potential shock haz-ard that could result in serious personal injury.

• Do not operate equipment if an interruption to the protective grounding is suspected. Ensure that the instrument remains inoperative.

• Use only the type of fuse specified.

• Do not use repaired fuses and avoid any situation that could short circuit the fuse.

• Unless absolutely necessary, do not attempt to adjust or perform any maintenance or repair procedure when the equipment is opened and connected to a power source at the same time. Any such procedure should only be performed by qualified service professional.

• Do not attempt any adjustment, maintenance or repair procedure to the equipment if first aid is not accessible.

• Disconnect the power supply cord from the equipment before adding or removing any components.

• Operating the equipment in the presence of flammable gases or fumes is extremely hazardous.

• Do not perform any operating or maintenance procedure that is not described in the Operating Manual.

Page 79: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page 11-3

7104000548-10/04-4

• Some of the equipment’s capacitors may be charged even when the equipment is not connected the power source.

11.3 SymbolsWhen any of these symbols appear on the unit, this is their meaning:

EQUIPOTENTIALITY–FUNCTIONALEARTH TERMINAL

PROTECTIVE GROUNDINGCONDUCTOR TERMINAL

CAUTION - REFER TO ACCOMPANYING DOCUMENTS

Page 80: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page 11-4 - Spirent Communications

7104000548-10/04-4

Page 81: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page A-1

7104000548-10/04-4

Appendix A MEASUREMENTS

A.1 Measurement of the DLS 410AData for the characteristics of the cables were obtained from the ANSI T1.417 and ITU-T G.996.1. Data for these types of cables are specified in terms of resistance, inductance, capacitance and conductance per meter (or km) of length of line as it varies with frequency

When measuring the insertion loss of a balanced line or line simulator throughout the ADSL 2++ frequency domain, the following method is recommended:

410A

Figure A.1 DLS 410A Electrical Characteristics Measurements.

In Figure A.1, Rg, RL and the coax cables match the unbalanced winding of the balun. The balanced wind-ing of the balun must be 100 Ohm, the reference impedance stipulated by ITU-T G.992.5. We recommend the transformer jig type DLS-4A03 (available as an optional accessory).

The transmitter and receiver could be the transmitting and receiving sections of a network analyzer.

Transformers and cables introduce errors of attenuation and phase. For accurate measurements, first perform calibration (normalization) by replacing the simulator with a direct connection.

WARNING: The use of unbalanced signals through the DLS 410A will usually give incorrect measure-ments.

Note: The above method and diagram apply only to the DLS 410A and not to other wireline simulators.

Figure A.2 "Test Setup with Noise Injection" shows an example of one of the test setup options:

Page 82: Operating Manual DLS 410A - Spirent

DLS 5404

DLS 410A Operating Manual

Page A-2 - Spirent Communications

7104000548-10/04-4

Figure A.2 Test Setup with Noise Injection

In Figure A.2, the DLS 411A is inter-connected with the DLS 412A by the cable labeled 7102040526, pro-vided as an accessory within the DLS 410A package. The DLS 410A is also connected to the DLS 5404 (part of the DLS 5200AP package) by two cables of the same type each labeled 7102040526, provided as an accessory within the DLS 5200AP.

A.2 Common Errors

There are three common errors:

• Coupling between input and output via the two transformers. When trying to measure attenuations of 60 dB or so, approximately 1/1000 of the input voltage, or 1/1000000 of the input power is present on the output. It is very easy for transformers - or even wires - placed close to each other to couple together far more than this. Take care to keep inputs and outputs separate.

• The use of a high impedance measuring device with no load from tip to ring at the receive end. This results in reflections due to a bad mismatch at the end of the line, and leads to very peculiar response curves.

• Ground injected directly onto the tip or ring of the wireline simulator. This almost always leads to a very noisy spectrum, with high background noise levels and often harmonically related spectrum “spikes”.

Page 83: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page B-1

7104000548-10/04-4

Appendix B BACKGROUND NOISE MEASUREMENT CONSIDERATIONS

Background noise measurements for the wireline simulator are performed with a spectrum analyzer, in this case, an Agilent 4395A spectrum/network analyzer.

Input A is used in spectrum-noise mode and the results are displayed in power spectral density units, i.e. dBm/Hz.

The noise floor of the Agilent 4395A with an input attenuator of 0 dB and resolution BW=30 kHz (input A not connected) is illustrated in the graph below:

Figure 17 – HP 439

Figure B.1 HP 4395A Noise Floor

Figure B.1 demonstrates the Agilent 4395A spectrum/network analyzer’s Noise Floor over a Bandwidth of 0-30MHz. The graph shows that for frequencies up to 10 MHz, the noise floor is about -144 dBm/Hz; for frequencies in the range 10-30 MHz, the noise floor is about -151 dBm/Hz. Hence, when measuring noises with values close to the noise floor of the analyzer itself, results are inaccurate in the sense that the ana-lyzer’s noise adds to the noise of the device under test (DUT); the displayed result will be worse than the real one.

In conclusion, the error introduced by the analyzer itself has to be taken into considerations when measuring noises with values close to -140 dBm/Hz.

Page 84: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page B-2 - Spirent Communications

7104000548-10/04-4

Page 85: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page C-1

7104000548-10/04-4

Appendix C TEST RESULTS

C.1 DLS 410A Test ResultsThe DLS 410A provides simulation of 4 loops topology for T1.417 and G996.1 Cable models. Sections C.2 - C.5 show results for loops simulated as per the T1.417 cable model. Sections C.6 - C.10 show results for loops simulated as per the G.996.1 cable model. For every loop topology, the DLS 410A has the capability to vary straight loops sections by 50 ft increments, and bridged tap sections by 10 ft increments.

C.2 Straight Loop Test Results - T1.417 Cable Model

The following results are based on a straight loop configuration.

Figure C.1 Insertion Loss:DLS 410A vs Theoretical, 3kft-21kft 26 AWG (3 kft steps)

Page 86: Operating Manual DLS 410A - Spirent

0.00E+00

1.00E-06

2.00E-06

3.00E-06

4.00E-06

5.00E-06

6.00E-06

7.00E-06

0.0E+00 5.0E+05 1.0E+06 1.5E+06 2.0E+06 2.5E+06 3.0E+06 3.5E+06 4.0E+06 4.5E+06

frequency [Hz]

Gro

up d

elay

[sec

] Measured DLS 410A Theoretical (T1.417)

DLS 410A Operating Manual

Page C-2 - Spirent Communications

7104000548-10/04-4

Figure C.2 Group delay:DLS 410 A vs Theoretical for distance of 3 kft 26 AWG

-200

-150

-100

-50

0

50

100

150

200

250

300

350

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Measured DLS 410A ImZin Measured DLS 410A ReZin Theoretical (T1.417) ImZin Theoretical (T1.417)

Figure C.3 Input Impedance for 3kft 26 AWG OhmStraight Loop With Termination of 100Ohm

Page 87: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page C-3

7104000548-10/04-4

C.3 Bridged Tap Loop Test Results - T1.417 Cable Model

The following results are based on the bridged-tap loop shown below, using T1.417 Cable Model:

Figure C.4 : Custom Bridged Tap Loop

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

0.0E+00 5.0E+05 1.0E+06 1.5E+06 2.0E+06 2.5E+06 3.0E+06 3.5E+06 4.0E+06 4.5E+06

frequency [Hz]

Inse

rtio

n lo

ss [d

B]

Measured DLS 410A

Theoretical (T1.417)

Figure C.5 Insertion Loss:DLS 410A vs Theoretical for Bridged Tap Loop (Figure C.4)

Page 88: Operating Manual DLS 410A - Spirent

-1.00E-06

1.00E-06

3.00E-06

5.00E-06

7.00E-06

9.00E-06

1.10E-05

1.30E-05

1.50E-05

0.0E+00 5.0E+05 1.0E+06 1.5E+06 2.0E+06 2.5E+06 3.0E+06 3.5E+06 4.0E+06 4.5E+06

frequency [Hz]

Gro

up d

elay

[sec

] Measured DLS 410A Theoretical (T1.417)

DLS 410A Operating Manual

Page C-4 - Spirent Communications

7104000548-10/04-4

Figure C.6 Group delay:DLS 410 A vs Theoretical for Bridged Tap Loop (Figure C.4)

-300

-200

-100

0

100

200

300

400

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Measured DLS 410A ReZin Theoretical (T1.417)ImZin Measured DLS 410A ImZin Theoretical (T1.417)

Figure C.7 Input Impedance from ATU-C side for Bridged Tap Loop 100Ohm termination

Page 89: Operating Manual DLS 410A - Spirent

-300

-200

-100

0

100

200

300

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Measured DLS 410A ReZin Theoretical (T1.417) ImZin Measured DLS 410A ImZin Theoretical (T1.417)

DLS 410A Operating Manual

Spirent Communications - Page C-5

7104000548-10/04-4

Figure C.8 Input Impedance from ATU-R side for Bridged Tap Loop, 100Ohm termination

C.4 ANSI #13 Test Results - T1.417 Cable Model

The following results are based on the modified ANSI #13 loop shown below, using T1.417 Cable Model. The first segment has been modified from the standard length of 9000 ft to 2000ft.

Figure C.9 ANSI #13 Loop - Modified

Page 90: Operating Manual DLS 410A - Spirent

-100

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

0.0E+00 5.0E+05 1.0E+06 1.5E+06 2.0E+06 2.5E+06 3.0E+06 3.5E+06 4.0E+06 4.5E+06

frequency [Hz]

Inse

rtio

n lo

ss [d

B]

Measured DLS 410A Theoretical (T1.417)

DLS 410A Operating Manual

Page C-6 - Spirent Communications

7104000548-10/04-4

Figure C.10 Insertion Loss:DLS 410 A vs Theoretical for modified ANSI #13 Loop

0.0E+00

2.0E-06

4.0E-06

6.0E-06

8.0E-06

1.0E-05

1.2E-05

1.4E-05

0.0E+00 5.0E+05 1.0E+06 1.5E+06 2.0E+06 2.5E+06 3.0E+06 3.5E+06 4.0E+06 4.5E+06

frequency [Hz]

Gro

up d

elay

[sec

]

Measured DLS 410A

Theoretical (T1.417)

Figure C.11 Group delay:DLS 410 A vs Theoretical for modified ANSI #13 Loop

Page 91: Operating Manual DLS 410A - Spirent

-200

-150

-100

-50

0

50

100

150

200

250

300

10000 100000 1000000 10000000

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Measured DLS 410A ReZin Theoretical (T1.417)ImZin Measured DLS 410A ImZin Theoretical (T1.417)

DLS 410A Operating Manual

Spirent Communications - Page C-7

7104000548-10/04-4

Figure C.12 Input Impedance from ATU-C side on modified ANSI #13 loop,termination of 100Ohm

-200

-150

-100

-50

0

50

100

150

200

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Measured DLS 410A ReZin Theoretical (T1.417)ImZin Measured DLS 410A ImZin Theoretical (T1.417)

Figure C.13 Input Impedance from ATU-R side on modified ANSI #13 loop,termination of 100Ohm

Page 92: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page C-8 - Spirent Communications

7104000548-10/04-4

C.5 CSA #4 Loop Test Results - T1.417 Cable Model

The following results are based on the modified CSA #4 loop shown below, using T1.417 Cable Model. Most segments has been modified from the standard lengths.

Figure C.14 CSA #4 Loop - modified

-100

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

0.0E+00 5.0E+05 1.0E+06 1.5E+06 2.0E+06 2.5E+06 3.0E+06 3.5E+06 4.0E+06 4.5E+06

frequency [Hz]

Inse

rtio

n lo

ss [d

B]

Measured DLS 410A

Theoretical (T1.417)

Figure C.15 Insertion Loss:DLS 410 A vs Theoretical for modified CSA #4 Loop

Page 93: Operating Manual DLS 410A - Spirent

0.0E+00

2.0E-06

4.0E-06

6.0E-06

8.0E-06

1.0E-05

1.2E-05

0.0E+00 5.0E+05 1.0E+06 1.5E+06 2.0E+06 2.5E+06 3.0E+06 3.5E+06 4.0E+06 4.5E+06

frequency [Hz]

Gro

up d

elay

[sec

] Measured DLS 410A

Theoretical (T1.417)

DLS 410A Operating Manual

Spirent Communications - Page C-9

7104000548-10/04-4

Figure C.16 Group delay:DLS 410 A vs Theoretical for modified CSA #4 Loop

-300

-200

-100

0

100

200

300

400

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Measured DLS 410 AImZin Measured DLS 410 AReZin Theoretical (T1.417)ImZin Theoretical (T1.417)

Figure C.17 Input Impedance from ATU-C side for modified CSA #4 loop,termination of 100Ohm

Page 94: Operating Manual DLS 410A - Spirent

-250

-200

-150

-100

-50

0

50

100

150

200

250

300

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Measured DLS 410 AImZin Measured DLS 410 AReZin Theoretical (T1.417)ImZin Theoretical (T1.417)

DLS 410A Operating Manual

Page C-10 - Spirent Communications

7104000548-10/04-4

Figure C.18 Input Impedance from ATU-R side for modified CSA #4 loop,termination of 100Ohm

Page 95: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page C-11

7104000548-10/04-4

C.6 Straight Loop Test Results - G.996.1 Cable Model

The following results are based on a straight loop configuration, using G.996.1 Cable Model.

Figure C.19 Insertion Loss:DLS 410A vs Theoretical , 3kft-21kft 26 AWG (3 kft steps)

Page 96: Operating Manual DLS 410A - Spirent

0.0E+00

5.0E-06

1.0E-05

1.5E-05

2.0E-05

2.5E-05

0.0E+00 2.0E+05 4.0E+05 6.0E+05 8.0E+05 1.0E+06 1.2E+06 1.4E+06

frequency [Hz]

Gro

up d

elay

[sec

]

Measured DLS 410A

Theoretical (G.996.1)

DLS 410A Operating Manual

Page C-12 - Spirent Communications

7104000548-10/04-4

Figure C.20 Group delay:DLS 410 A vs Theoretical for distance of 9 kft 26 AWG

-250

-200

-150

-100

-50

0

50

100

150

200

250

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Maesured on DLS 410 AImZin Maesured on DLS 410 AReZin Theoretical (G.996.1)ImZin Theoretical (G.996.1)

Figure C.21 Input Impedance for 9kft 26 AWG Straight Loop With Termination of 100Ohm

Page 97: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Spirent Communications - Page C-13

7104000548-10/04-4

C.7 Bridged Tap Loop Test Results - G.996.1 Cable Model

The following results are based on the bridged-tap loop shown below, using G.996.1 Cable Model:

Figure C.22 : Custom Bridged Tap Loop

-100

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

0.0E+00 2.0E+05 4.0E+05 6.0E+05 8.0E+05 1.0E+06 1.2E+06 1.4E+06

frequency [Hz]

Inse

rtio

n lo

ss [d

B]

Measured DLS 410A

Theoretical (G.996.1)

Figure C.23 Insertion Loss:DLS 410A vs Theoretical for Bridged Tap Loop (Figure C.22)

Page 98: Operating Manual DLS 410A - Spirent

0.00E+00

5.00E-06

1.00E-05

1.50E-05

2.00E-05

2.50E-05

3.00E-05

0.0E+00 2.0E+05 4.0E+05 6.0E+05 8.0E+05 1.0E+06 1.2E+06 1.4E+06

frequency [Hz]

Gro

up d

elay

[sec

]

Measured DLS 410A Theoretical (G.996.1)

DLS 410A Operating Manual

Page C-14 - Spirent Communications

7104000548-10/04-4

Figure C.24 Group delay:DLS 410 A vs Theoretical for Bridged Tap Loop (Figure C.22)

-250

-200

-150

-100

-50

0

50

100

150

200

250

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Maesured on DLS 410 AReZin Theoretical (G.996.1)ImZin Maesured on DLS 410 AImZin Theoretical (G.996.1)

Figure C.25 Input Impedance from ATU-C side for Bridged Tap Loop With Termination of 100Ohm

Page 99: Operating Manual DLS 410A - Spirent

-250

-200

-150

-100

-50

0

50

100

150

200

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Maesured on DLS 410 AReZin Theoretical (G.996.1)ImZin Maesured on DLS 410 AImZin Theoretical (G.996.1)

DLS 410A Operating Manual

Spirent Communications - Page C-15

7104000548-10/04-4

Figure C.26 Input Impedance from ATU-R side for Bridged Tap Loop With Termination of 100Ohm

C.8 ANSI #13 Test Results - G.996.1 Cable Model

The following results are based on the standard ANSI #13 loop shown below, using G.996.1 Cable Model:

.

Figure C.27 ANSI #13 Loop

Page 100: Operating Manual DLS 410A - Spirent

-100

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

0.0E+00 2.0E+05 4.0E+05 6.0E+05 8.0E+05 1.0E+06 1.2E+06

frequency [Hz]

Inse

rtio

n lo

ss [d

B]

Measured DLS 410A

Theoretical (G.996.1)

DLS 410A Operating Manual

Page C-16 - Spirent Communications

7104000548-10/04-4

Figure C.28 Insertion Loss:DLS 410 A vs Theoretical for standard ANSI #13 Loop

0.0E+00

5.0E-06

1.0E-05

1.5E-05

2.0E-05

2.5E-05

3.0E-05

3.5E-05

4.0E-05

4.5E-05

0.0E+00 1.0E+05 2.0E+05 3.0E+05 4.0E+05 5.0E+05 6.0E+05 7.0E+05 8.0E+05 9.0E+05

frequency [Hz]

Gro

up d

elay

[sec

]

Measured DLS 410A Theoretical (G.996.1)

Figure C.29 Group delay:DLS 410 A vs Theoretical for standard ANSI #13

Page 101: Operating Manual DLS 410A - Spirent

-250

-200

-150

-100

-50

0

50

100

150

200

250

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Maesured on DLS 410 AReZin Theoretical (G.996.1)ImZin Maesured on DLS 410 AImZin Theoretical (G.996.1)

DLS 410A Operating Manual

Spirent Communications - Page C-17

7104000548-10/04-4

Figure C.30 Input Impedance from ATU-C side on standard ANSI #13 loop, termination of 100Ohm

-150

-100

-50

0

50

100

150

200

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Maesured on DLS 410 AReZin Theoretical (G.996.1)ImZin Maesured on DLS 410 AImZin Theoretical (G.996.1)

Figure C.31 Input Impedance from ATU-R side on standard ANSI #13 loop,termination of 100Ohm

Page 102: Operating Manual DLS 410A - Spirent

DLS 410A Operating Manual

Page C-18 - Spirent Communications

7104000548-10/04-4

C.9 CSA #4 Loop Test Results - G.996.1 Cable Model

The following results are based on the modified CSA #4 loop shown below, using G.996.1 Cable Model:

.

Figure C.32 CSA #4 Loop

-100

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

0.0E+00 2.0E+05 4.0E+05 6.0E+05 8.0E+05 1.0E+06 1.2E+06 1.4E+06 1.6E+06 1.8E+06 2.0E+06

frequency [Hz]

Inse

rtio

n lo

ss [d

B]

Measured DLS 410A Theoretical (G.996.1)

Figure C.33 Insertion Loss:DLS 410 A vs Theoretical for standard CSA #4 Loop

Page 103: Operating Manual DLS 410A - Spirent

0.0E+00

5.0E-06

1.0E-05

1.5E-05

2.0E-05

2.5E-05

3.0E-05

0.0E+00 2.0E+05 4.0E+05 6.0E+05 8.0E+05 1.0E+06 1.2E+06 1.4E+06 1.6E+06 1.8E+06 2.0E+06

frequency [Hz]

Gro

up d

elay

[sec

] Measured DLS 410A Theoretical (G.996.1)

DLS 410A Operating Manual

Spirent Communications - Page C-19

7104000548-10/04-4

Figure C.34 Group delay:DLS 410 A vs Theoretical for standard CSA #4 Loop

-250

-200

-150

-100

-50

0

50

100

150

200

250

300

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

dacn

e [O

hms]

ReZin Maesured on DLS 410 AReZin Theoretical (G.996.1)ImZin Maesured on DLS 410 AImZin Theoretical (G.996.1)

Figure C.35 Input Impedance from ATU-C side for standard CSA #4 loop,termination of 100Ohm

Page 104: Operating Manual DLS 410A - Spirent

-250

-200

-150

-100

-50

0

50

100

150

200

250

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Maesured on DLS 410 AReZin Theoretical (G.996.1)ImZin Maesured on DLS 410 AImZin Theoretical (G.996.1)

DLS 410A Operating Manual

Page C-20 - Spirent Communications

7104000548-10/04-4

Figure C.36 Input Impedance from ATU-R side for standard CSA #4 loop,termination of 100Ohm

C.10 CSA #4 (Modified) Loop Test Results - G.996.1 Cable Model

The following results are based on the modified CSA #4 loop shown below, using G.996.1 Cable Model. Most segments have been modified from the standard lengths.

Figure C.37 Modified CSA #4 Loop

Page 105: Operating Manual DLS 410A - Spirent

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

0.0E+00 5.0E+05 1.0E+06 1.5E+06 2.0E+06 2.5E+06 3.0E+06 3.5E+06 4.0E+06 4.5E+06

frequency [Hz]

Inse

rtio

n lo

ss [d

B]

Measured DLS 410A Theoretical (G.996.1)

DLS 410A Operating Manual

Spirent Communications - Page C-21

7104000548-10/04-4

Figure C.38 Insertion Loss:DLS 410 A vs Theoretical for modified CSA #4 Loop

0.0E+00

2.0E-06

4.0E-06

6.0E-06

8.0E-06

1.0E-05

1.2E-05

1.4E-05

0.0E+00 5.0E+05 1.0E+06 1.5E+06 2.0E+06 2.5E+06 3.0E+06 3.5E+06 4.0E+06 4.5E+06

frequency [Hz]

Gro

up d

elay

[sec

]

Measured DLS 410A Theoretical (G.996.1)

Figure C.39 Group delay:DLS 410 A vs Theoretical for modified CSA #4 Loop

Page 106: Operating Manual DLS 410A - Spirent

-300

-200

-100

0

100

200

300

400

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Maesured on DLS 410 AReZin Theoretical (G.996.1)ImZin Maesured on DLS 410 AImZin Theoretical (G.996.1)

DLS 410A Operating Manual

Page C-22 - Spirent Communications

7104000548-10/04-4

Figure C.40 Input Impedance from ATU-C side for modified CSA #4 loop,termination of 100Ohm

-250

-200

-150

-100

-50

0

50

100

150

200

250

300

1.0E+04 1.0E+05 1.0E+06 1.0E+07

frequency [Hz]

Impe

danc

e [O

hms]

ReZin Maesured on DLS 410 AReZin Theoretical (G.996.1)ImZin Maesured on DLS 410 AImZin Theoretical (G.996.1)

Figure C.41 Input Impedance from ATU-R side for modified CSA #4 loop,termination of 100Ohm