open19 technology… · brick form factors •four brick form factors –brick (½ wide 1ru)...

15
Open19 Technology Zaid Ali Kahn | Head of Infrastructure Engineering 25 th June, 2019

Upload: others

Post on 21-Aug-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

Open19 Technology

Zaid Ali Kahn | Head of Infrastructure Engineering

25th June, 2019

Page 2: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

Open19 Technology

Page 3: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

• Passive mechanical cage

• 12RU and 8RU options

• 2RU modularity

– 4x Bricks

– 2x Double High Half Width

– 2x Double wide

– 1x Double High

• Snap-on rear opening

Brick Cage

Page 4: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

Brick Form Factors• Four brick form factors

– Brick (½ wide 1RU)

– Double High Half Width – (2RU)

– Double Wide Brick (1RU)

– Double High Brick (2RU)

• Linear power and data growth

• Self Sustained – EMI & Safety & cooling

• 100G Blind Mate network

Page 5: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

Cabling System

Open 19 Power Cables

400W per server – 8/12 servers per cable

Open 19 Data Cables

100G Per server – 8/12 servers per cable

Page 6: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

Open19 Power Shelf1RU, 19.2Kw (6x3.2Kw)

Management via GE port

Full AC and DC range

Per server protection and monitoring

Fully redundant A/B inputs

Multi-Source for the shelf and modules

Page 7: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

Open19 Technology Benefits

Standard 19” rack

Any Location

Any 19” Rack

Rack level savings

Solution savings

Cost

5-6X faster rack level

integration

Extremely simple

cabling

Integration

A/B 2N power

No central controllers

Per server monitoring

Redundancy

Zero server power

supplies

96% power

conservation

Efficiency

Page 8: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

Open19 Live in Production

@LinkedIn

Page 9: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

Olympus Project

and

Open19

Page 10: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

• Different Cage Form Factors

• New “Server” models

Future

Page 11: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

Cabling System

Open 19 Data Cables

Open 19 Power Cables

400W per server – 8/12 servers per cable

100G Per server – 8/12 servers per cable

Page 12: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

Open19 Live[in] Production

@LinkedIn

Page 13: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

Brick Form Factors• Four brick form factors

– Brick (½ wide 1RU)

– Double High Half Width – (2RU)

– Double Wide Brick (1RU)

– Double High Brick (2RU)

• Linear power and data growth

• Self Sustained – EMI & Safety & cooling

• 100G Blind Mate network

Brick Double High Half

Width Brick

Double Wide

Brick

Double High

Double Wide Brick

Page 14: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

Open19 Power Shelf1RU, 19.2Kw (6x3.2Kw)

Management via GE port

Full AC and DC range

Per server protection and monitoring

Fully redundant A/B inputs

Multi-Source for the shelf and modules

Page 15: Open19 Technology… · Brick Form Factors •Four brick form factors –Brick (½ wide 1RU) –Double High Half Width –(2RU) –Double Wide Brick (1RU) –Double High Brick (2RU)

Thank you