![Page 1: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/1.jpg)
C O M P A C T F L U O R E S C E N T L I G H T I N G
LIGHTING FOR ARCHITECTURE
T O O L S F O R T H E L I G H T I N G P R O F E S S I O N A L
![Page 2: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/2.jpg)
![Page 3: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/3.jpg)
![Page 4: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/4.jpg)
4
BE L F E R P R O D U C T S
A R E D E S I G N E D T O
I L L U M I N AT E A N Y
E N V I R O N M E N T W H E R E
T H E O B J E C T I V E I S T O
C R E AT E V I S U A L
I N T E R E S T W H I L E
R E S P E C T I N G T H E
A R C H I T E C T U R E.
Elegant Solutions for High Profile Lighting Designs
![Page 5: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/5.jpg)
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 5
A PI O N E E R I N CO M PA C T FL U O R E S C E N T AP P L I C AT I O N S
With the advent of compact linear fluorescent technology in the late 1970s, Belfer was the first manufacturer to develop compactfluorescent strip lighting for illuminating architectural details such as coves, ceilings, soffits and valances. It remains a primaryfocus of the company to this day.
In 1990, Belfer again led the industry with theintroduction of the first field curvable compactlinear fluorescent, its renowned FX™ series.For the first time, the fixtures could be curvedin the field, not in the factory.
In 1994, Belfer improved its field curvable linewith the introduction of its FX2™ line. TheFX2 line is modular in design, meeting thedemands of actual job-site conditions forcurved lighting of any length, to very tightradii. At the same time, we introduced ourpatented Ramp™ system, which eliminatesany possibility of shadows while increasinglight output 20%.
Because “the best never rest,” Belferinnovated the lighting industry’s only integralstraight and field curvable compact linearfluorescent system, the NX2/FX2™ Series.NX2/FX2 allows complete integration ofstraight and field curvable lengths in virtuallyany configuration. We ship custom lightingfrom stock.
All Belfer products are designed, built andperformance tested to the highest standardsin our modern U.S. plant. From concept, toselection of materials and components, toproduction, the quality of our product andyour project comes first. UL and CUL listingsensure electrical safety and adherence tocodes.
We cordially invite your inquiry.
Your Hidden Advantage®
![Page 6: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/6.jpg)
The NX2/FX2 System offers many distinct installation and maintenance advantages:
• The NX2/FX2 system is through wired…Just connect wires and screw joints together. No “pulling” of wire or cable required.
• The NX2/FX2 system has external mounting clips…No need to open units to secure the fixture to the mounting surface.
• The NX2/FX2 system provides for easy ballast replacement…For service, the top cap lifts up, allowing access to the ballast.
• The NX2/FX2 system reduces freight costs…Its field curvable design ships straight in standard lengths for most common carriers.
The NX2/FX2™ Seamless Design System is a fully
linkable, formed aluminum system that allows complete
integration of straight and field curvable lengths in
virtually any configuration. NX2™ is the suffix for
Belfer’s straight, non-curving compact fluorescent
sections. FX2™ is the suffix for field curvable sections.
Together, they can be joined to form a single, seamless,
continuous system.
NX2 & FX2 can be specified as lamp up or lamp down. NX2S & FX2S
are specified as lamp in or lamp out. All are available in standard lengths
including individual add-on modules to complete a run.
Field curvable means no need for field measurements, no fabrication sheets, no set-up charges
for custom products. All you need to know are the inside and outside radii of the coves. The minimum
cove radius is listed for each lamp size in each lamp configuration.
SeamlessDesign System
lamp up lamp down lamp outlamp in
NX2 TO FX2 NX2S TO FX2S
6 These products protected by one or more of the following U.S. patents 5,448,460, 5,221,139 and 5,452,187. Other patents pending.
![Page 7: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/7.jpg)
NX2™ to FX2™
SEAMLESS DESIGN SYSTEM
Choose NX2 or FX2 for lamps positioned up or down.
NX2S™ to FX2S™
SEAMLESS DESIGN SYSTEM
Choose NX2S or FX2S for lamps positioned on the inside or outside of the fixture.
2855 FX2S 40W
2855 NX2S 40W
2801 FX2 9W
2855 NX2S TO FX2S COMBINATION40 wat t lamps fac ing out
7BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m
2801 NX2 9W
2801 NX2 TO FX2 COMBINATION9 wat t lamps fac ing up
![Page 8: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/8.jpg)
FO R M E D AL U M I N U M CO N S T R U C T I O N
Fully linkable formed aluminum system allows completeintegration of straight and field curvable lengths.
SW I V E L SO C K E T S
Allow for easy relamping in tight curves.
EX T E R N A L MO U N T I N G CL I P S
No need to open units to secure the fixture to the mountingsurface.
RE M O VA B L E BA L L A S T
For service, the top cap lifts up, allowing access to theballast.
RE D U C E D IN S TA L L E D CO S T S
Through wired preassembled units reduce freight and installation costs.
8
Features
![Page 9: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/9.jpg)
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m
MO D I F I C AT I O N S A N D SP E C I A L S
If you have applications which dictate modification of our standard product, please contact your local Belfer representative. Inaddition to modifications, Belfer has complete custom capabilities for custom projects. Our team of customer service and technicalspecialists are at your disposal to answer questions and offer advice about application, lamp placement, and lighting objectives.
EA S Y LE N G T H AD J U S T M E N T
Modular system allows for length adjustment in the field.
9
![Page 10: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/10.jpg)
A Checklist for Effective Cove Lighting
1. CHOOSE THE PROPER LAMP
2. COMMON FIXTURE PLACEMENTS
3. PERFORMANCE FIXTURE PLACEMENTS
- MAXIMIZE LIGHT OUTPUT FROM COVE
4. MINIMIZING / ELIMINATING SHADOWS
- PLAN FOR EVEN LIGHT DISTRIBUTION
5. PROPER INTERIOR COVE SURFACE
10
![Page 11: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/11.jpg)
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 11
1. CHOOSE THE PROPER LAMP
2. COMMON FIXTURE PLACEMENTS
Whatever your objective for cove lighting, maximizing the output of the light is most desirable. Fixture placementin relation to the aperture (the opening) of the cove is the factor which most affects output. The most commonimpediment to light output is poor placement of fixtures in the cove.
The closer the lamps are to the aperture of the cove, the more light will escape the cove.
✓
✓
Lumen Output ChartLAMP LUMENS LAMPS LUMENS LAMP LIFE
(nominal per lamp) (per foot) (per foot) (nominal)
2801 SERIES9 Watt Twin Tube 600 1.50 900 10,000 hrs.13 Watt Twin Tube 900 1.50 1,350 10,000 hrs.
2850 SERIES18 Watt Twin Tube/RS 1,250 1.00 1,250 20,000 hrs.39 Watt Twin Tube 2,900 0.67 1,935 12,000 hrs.40 Watt Twin Tube 3,150 0.50 1,575 20,000 hrs.50 Watt Twin Tube 4,000 0.50 2,000 14,000 hrs.
2855 RAMP® SERIES9 Watt Twin Tube 600 3.00 1,800 10,000 hrs.13 Watt Twin Tube 900 3.00 2,700 10,000 hrs.18 Watt Twin Tube/RS 1,250 1.50 1,875 20,000 hrs.39 Watt Twin Tube 2,900 0.86 2,486 12,000 hrs.40 Watt Twin Tube 3,150 0.60 1,890 20,000 hrs.50 Watt Twin Tube 4,000 0.60 2,400 14,000 hrs.
2880 SERIES26 Watt Quad Tube 1,800 1.50 2,700 10,000 hrs.32 Watt Hex Tube 2,400 1.50 3,600 10,000 hrs.42 Watt Hex Tube 3,200 1.50 4,800 10,000 hrs.
ceiling
return of cove
wall
ceiling
return of cove
wall
The Belfer Compact Fluorescent Cove Lighting System begins with identifying the proper lamp and desired lumenoutput. If the need is to create a soft glow above the cove, low wattage compact fluorescent lamps should beselected. If the need is to create ambient light below the cove, a higher wattage lamp should be used. The BelferSystem is available in 9W and 13W twin tube, 26W quad, 32W and 42W hex and 18W, 39W, 40W and 50W biaxlamps. Select the appropriate wattage, lamp and lumen output… this will determine which Belfer system is right foryour needs.
The following chart shows the lumen output per lamp, lamps per foot, lumen output per foot and lamp life of eachlamp offered based on Belfer standard lamp spacing.
Placing fixtures deep inside the cove, against thereturn, results in maximum light being trapped inside.
Placing fixtures deep inside the cove, against the farwall can create shadows on the inner wall.
![Page 12: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/12.jpg)
12
For coves above 9 feetuse the horizontal line ofsight or, as an alternative,use the actual line ofsight. This is determinedfrom a point farthest awayfrom cove at a height ofseven feet, while the coveis still visible.
3. PERFORMANCE FIXTURE PLACEMENTS - MAXIMIZE LIGHT OUTPUT FROM COVE
To maximize light output,fixtures must be close tothe line of sight. For covesunder 9 feet from the floor,use the horizontal line ofsight, by drawing ahorizontal line from the topof the return to the insideof the cove.
✓
return of cove
horizontalline ofsight
actual line of sight(angle exaggerated)
reargradient
area
frontgradientarea
Place fixture to position lamps one inch below the actual line of sight.
spacer (if necessary)
EXAMPLE 2
EXAMPLE 1
Highest efficiency isgained when the fixturesare mounted in a sideposition, which maximizesthe amount of lightescaping the cove intothe space.
EXAMPLE 3
return of cove
horizontalline of sightrear
gradientarea
frontgradientarea
spacer (if necessary)
horizontal line of sight
actual line of sight(angle exaggerated)
reargradient
area
frontgradientarea
spacer (if necessary)
return of cove
![Page 13: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/13.jpg)
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 13
A matte white finish inside the cove increases light reflectivity and reduces light discoloration while increasing efficiency.Walls and ceilings that are matte white produce optimum results.
In addition to proper placement to maximize light output, care should be taken to eliminate or minimize shadows. This canbe accomplished by maintaining the minimum distance between the light source and the nearest visible surface to the light.
4. MINIMIZING/ELIMINATING SHADOWS - PLAN FOR EVEN LIGHT DISTRIBUTION✓
5. PROPER INTERIOR COVE SURFACE✓
2801 fixture exampleminimum distance is 4"
scale 3/8
drawings not to scale
4"4"
5" 4"2"
2"
28502801 and 2880
2855
Maintain minimum distance between the light source and the nearest visible surface. This distance is 5" for 2850 and 4" for 2801/2880.
Specifying the patented Belfer Ramp® (2855) with overlapping lamps virtually assures shadow-free lighting. Lampplacement can be as little as 2" from nearest visibly lit surface to avoid hot spots.
MINIMUM DISTANCES FOR SHADOWLESS APPLICATIONS
![Page 14: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/14.jpg)
14
THE BELFER RAMP ® SERIES IS THE
ORIGINAL SHADOWLESS COMPACT
FLUORESCENT L IGHT STRIP. BY
OVERLAPPING ITS LAMPS AT A
CONTINUOUS ANGLE AND COVERING
ADJACENT SOCKETS AND CATHODES,
NOT ONLY DOES THE RAMP ® EL IMINATE
SHADOWS, BUT LUMENS PER FOOT
INCREASES 20% TO 100% DEPENDING
UPON THE LAMP. THE RAMP ® FEATURES
AN EXCLUSIVE CONTINUOUS GROUND
PLANE WHICH ENSURES TROUBLE-FREE
STARTING AND DIMMING, WHILE
MAXIMIZ ING LAMP LIFE.
RAMP ® F IXTURES UTIL IZ ING HIGH
PERFORMANCE 18W, 39W, 40W AND
50W LAMPS PRODUCE 20% MORE
LUMENS PER FOOT THAN OTHER
COMPACT FLUORESCENT STRIPS. IN
ADDIT ION WE OFFER RAMP ® F IXTURES
UTIL IZ ING 9W AND 13W TWIN TUBE
COMPACT FLUORESCENTS. BY
OVERLAPPING LAMPS, LUMEN OUTPUT
PER FOOT DOUBLES OVER OUR MODEL
2801 END-TO-END VERSION.
OUR 2855 RAMP ® SERIES PROVIDES
THE L IGHTING DESIGNER WITH AN EVEN
DISTRIBUTION OF INDIRECT L IGHTING
AND AN UNUSUALLY FLEXIBLE METHOD
OF LIGHTING LINEAR, ROUNDED AND
CONTOURED COVES AND VALANCES.
2855 SeriesThe Ramp®
These products protected by one or more of the following U.S. patents 5,448,460, 5,221,139 and5,452,187. Other patents pending.
2855 FX2 40 WATT Lamps fac ing up
2855 NX2S 40 WATT
![Page 15: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/15.jpg)
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m
2855 FX2 13 WATT Lamps fac ing up
TABLE OF CONTENTS
2855 NX2 & FX2 40W/50W. . . . . . . . page 16
2855 NX2S & FX2S 40W/50W . . . . . page 17
2855 NX2 & FX2 39W. . . . . . . . . . . . page 18
2855 NX2S & FX2S 39W . . . . . . . . . page 19
2855 NX2 & FX2 18W. . . . . . . . . . . . page 20
2855 NX2S & FX2S 18W . . . . . . . . . page 21
2855 NX2 & FX2 9W/13W. . . . . . . . . page 22
2855 NX2S & FX2S 9W/13W . . . . . . page 23
Compact Fluorescent Lamps . . . . . . page 46
Lumen Output Chart. . . . . . . . . . . . . page 11
15
![Page 16: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/16.jpg)
Minimum Cove Parametersinside radius 56"outside radius 61"
Ordering Formatchoose one from each category
DAMP LOCATION
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
2855linearfixture
NX2seamless straightlamp up or down
FX2field curvablelamp up or down
4040 wattcompactfluorescent
5050 wattcompactfluorescent
1120 volt
2277 volt
Hhigh power factor(40 watt, 40" & 20" only)
Eelectronic
Ddimming
6060" length(3 lamps, 40 watt only)
4040" length(2 lamps)
2020" length(1 lamp)
2855 N
X2 &
FX
240W
& 5
0W
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m16
• High Performance Compact Fluorescent Lamp Options:• 40 Watt (2G11) High Performance Compact Fluorescent• 50 Watt (2G11) High Performance Compact Fluorescent
• Voltage Options:• 120 Volt• 277 Volt
• Ballast Options:• High Power Factor (40 watt only)• Electronic• Dimming
• 20" On Center Spacing
40 & 50 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2855 NX2/FX2™ Ramp®
4¹³⁄₁₆"
3¹⁄₈"
2⁵⁄₈" without bracket
40"
20"
60"
Allow 4" for lamp overhang and removal
![Page 17: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/17.jpg)
Ordering Formatchoose one from each category
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 17
DAMP LOCATION
• High Performance Compact Fluorescent Lamp Options:• 40 Watt (2G11) High Performance Compact Fluorescent• 50 Watt (2G11) High Performance Compact Fluorescent
• Voltage Options:• 120 Volt• 277 Volt
• Ballast Options:• High Power Factor (40 watt only)• Electronic• Dimming
• 20" On Center Spacing
2855 N
X2S &
FX
2S
40W
& 5
0W
40 & 50 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2855 NX2S/FX2S™ Ramp®
Allow 4" for lamp overhang and removal
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
40"
20"
60"
Minimum Cove ParametersLamp Out
inside radius 56"outside radius 62"
Lamp Ininside radius 53"outside radius 59"
lamp clipinlowposition
lamp clipin highposition
5¹⁄₈"
4¹³⁄₁₆"
3¹⁄₈"
lampclipin high position
lamp clip in lowposition
2⁵⁄₈" without bracket
2855linearfixture
NX2Sseamless straightlamp in or out
FX2Sfield curvablelamp in or out
4040 wattcompactfluorescent
5050 wattcompactfluorescent
1120 volt
2277 volt
Hhigh power factor(40 watt, 40" & 20" only)
Eelectronic
Ddimming
6060" length(3 lamps, 40 watt only)
4040" length(2 lamps)
2020" length(1 lamp)
![Page 18: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/18.jpg)
Minimum Cove Parametersinside radius 38"outside radius 45"
Ordering Formatchoose one from each category
2855 N
X2 &
FX
239W
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m18
DAMP LOCATION
• 39 Watt (2G11) High Performance Compact Fluorescent Lamp
• Voltage Options:• 120 Volt• 277 Volt
• Ballast Options:• High Power Factor• Electronic• Dimming
• 14" On Center Spacing
39 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2855 NX2/FX2™ Ramp®
4¹³⁄₁₆"
3¹⁄₈"
2⁵⁄₈" without bracket
28"
14"
42"
2855linearfixture
NX2seamless straightlamp up or down
FX2field curvablelamp up or down
3939 wattcompactfluorescent
1120 volt
2277 volt
Hhigh power factor(28" and 14" only)
Eelectronic
Ddimming
4242" length(3 lamps)
2828" length(2 lamps)
1414" length(1 lamp)
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
Allow 4" for lamp overhang and removal
![Page 19: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/19.jpg)
Ordering Formatchoose one from each category
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 19
DAMP LOCATION
• 39 Watt (2G11) High Performance Compact Fluorescent Lamp
• Voltage Options:• 120 Volt• 277 Volt
• Ballast Options:• High Power Factor• Electronic• Dimming
• 14" On Center Spacing
2855 N
X2S &
FX
2S
39W
39 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2855 NX2S/FX2S™ Ramp®
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
5¹⁄₈"
4¹³⁄₁₆"
3¹⁄₈"
lamp clipin high position
lamp clip in low position
2⁵⁄₈" without bracket
14"
28"
42"
2855linearfixture
NX2Sseamless straightlamp in or out
FX2Sfield curvablelamp in or out
3939 wattcompactfluorescent
1120 volt
2277 volt
Hhigh power factor(28" and 14" only)
Eelectronic
Ddimming
lampclip inlowposition
lampclip inhighposition
Minimum Cove ParametersLamp Out
inside radius 39"outside radius 45"
Lamp Ininside radius 35"outside radius 42"
Allow 4" for lamp overhang and removal
4242" length(3 lamps)
2828" length(2 lamps)
1414" length(1 lamp)
![Page 20: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/20.jpg)
Ordering Formatchoose one from each category
2855 N
X2 &
FX
218
W
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m20
DAMP LOCATION
18 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2855 NX2/FX2™ Ramp®
Allow 4" for lamp overhang and removal
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
4¹³⁄₁₆"
3¹⁄₈"
2⁵⁄₈" without bracket
8"
48"
32"
16"
2855linearfixture
NX2seamless straightlamp up or down
FX2field curvablelamp up or down
1818 wattcompactfluorescent(rapid start)
1120 volt
2277 volt
Eelectronic
4848" length(6 lamps)
3232" length (4 lamps)
1616" length(2 lamps)
88" length(1 lamp)
Minimum Cove Parametersinside radius 23¹⁄₂"outside radius 28¹⁄₂"
• 18 Watt (2G11) High Performance Compact Fluorescent Lamp (rapid start)
• Voltage Options:• 120 Volt• 277 Volt
• Electronic Ballast
• 8" On Center Spacing
![Page 21: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/21.jpg)
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
Ordering Formatchoose one from each category
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 21
DAMP LOCATION
• 18 Watt (2G11) High Performance Compact Fluorescent Lamp (rapid start)
• Voltage Options:• 120 Volt• 277 Volt
• Electronic Ballast
• 8" On Center Spacing
2855 N
X2S &
FX
2S
18W
18 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2855 NX2S/FX2S™ Ramp®
lampclip inlowposition
lampclip inhighposition
Minimum Cove ParametersLamp Out
inside radius 21¹⁄₂"outside radius 28³⁄₈"
Lamp Ininside radius 32⁷⁄₈"outside radius 39"
5¹⁄₈"
4¹³⁄₁₆"
3¹⁄₈"
lamp clipin high position
lamp clip in low position
2⁵⁄₈" without bracket
8"16"
48"
32"
2855linearfixture
NX2Sseamless straightlamp in or out
FX2Sfield curvablelamp in or out
1818 wattcompactfluorescent(rapid start)
1120 volt
2277 volt
Eelectronic
4848" length (6 lamps)
3232" length (4 lamps)
1616" length(2 lamps)
88" length(1 lamp)
Allow 4" for lamp overhang and removal
![Page 22: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/22.jpg)
Ordering Formatchoose one from each category
2855 N
X2 &
FX
2
9W
& 1
3W
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m22
DAMP LOCATION
• Compact Fluorescent Lamp Options:• 9 Watt (G23) Compact Fluorescent• 13 Watt (GX23) Compact Fluorescent
• Voltage Options:• 120 Volt• 277 Volt
• High Power Factor Ballast
• 4" On Center Spacing
9 & 13 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2855 NX2/FX2™ Ramp®
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
4⁷⁄₈"
3¹⁄₈" 8"
48"
24"
2855linearfixture
NX2seamless straight lamp up or down
FX2field curvablelamp up or down
99 wattcompactfluorescent
1313 wattcompactfluorescent
1120 volt
2277 volt
Hhigh power factor
4848" length(12 lamps)
2424" length(6 lamps)
88" length(2 lamps)
Minimum Cove Parametersinside radius 23¹⁄₂"outside radius 28¹⁄₂"
Allow 4" for lamp overhang and removal2⁵⁄₈" without bracket
![Page 23: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/23.jpg)
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
Ordering Formatchoose one from each category
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 23
DAMP LOCATION
• Compact Fluorescent Lamp Options:• 9 Watt (G23) Compact Fluorescent• 13 Watt (GX23) Compact Fluorescent
• Voltage Options:• 120 Volt• 277 Volt
• High Power Factor Ballast
• 4" On Center Spacing
2855 N
X2S &
FX
2S
9W
& 13
W
9 & 13 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2855 NX2S/FX2S™ Ramp®
4⁷⁄₈"
3¹⁄₈"
2⁵⁄₈" without bracket
Minimum Cove ParametersLamp Out
inside radius 21¹⁄₂"outside radius 27"
Lamp Ininside radius 18¹⁄₂"outside radius 24"
8"
48"
24"
Allow 4" for lamp overhang and removal
2855linearfixture
NX2Sseamless straightlamp in or out
FX2Sfield curvablelamp in or out
99 wattcompactfluorescent
1313 wattcompactfluorescent
1120 volt
2277 volt
Hhigh power factor
4848" length(12 lamps)
2424" length(6 lamps)
88" length(2 lamps)
![Page 24: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/24.jpg)
THE 2850 COMPACT FLUORESCENT
SERIES COMBINES HIGH EFF IC IENCY,
COLOR CORRECTED 18W, 39W, 40W
AND 50W LAMPS WITH OUR PATENTED
SEAMLESS STRAIGHT TO FIELD
CURVABLE SYSTEM. AVAILABLE IN MULTI
LAMP LENGTHS FOR COST EFFECTIVE
INSTALLAT IONS, THIS SERIES EMPLOYS
RAPID START, H IGH POWER FACTOR,
DIMMING OR ELECTRONIC BALLASTS
WITHIN ITS SL IM, SAT IN ANODIZED
ALUMINUM PROFILE. STRAIGHT AND
CURVED LENGTHS CAN BE COMBINED TO
CREATE CONTINUOUS WALL TO WALL
L IGHTING. DARK CORNERS AND DARK
ENDS ARE EL IMINATED. L IFT UP SOCKETS
ALLOW FOR EASY RELAMPING IN THE
MOST RESTRICT IVE OF JOB CONDIT IONS.
The 2850 Series
These products protected by one or more of the following U.S. patents 5,448,460, 5,221,139 and5,452,187. Other patents pending.
24
2850 FX2S 39 WATTLamps fac ing in
2850 NX2 40 WATT
![Page 25: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/25.jpg)
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m
2850 FX2 40 WATTLamps fac ing up
2850 NX2S CONNECTED TO FX2S 18 WATTLamps fac ing in
TABLE OF CONTENTS
2850 NX2 & FX2 40W/50W. . . . . . . . page 26
2850 NX2S & FX2S 40W/50W . . . . . page 27
2850 NX2 & FX2 39W. . . . . . . . . . . . page 28
2850 NX2S & FX2S 39W . . . . . . . . . page 29
2850 NX2 & FX2 18W. . . . . . . . . . . . page 30
2850 NX2S & FX2S 18W . . . . . . . . . page 31
Compact Fluorescent Lamps . . . . . . page 46
Lumen Output Chart. . . . . . . . . . . . . page 11
25
![Page 26: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/26.jpg)
Ordering Formatchoose one from each category
2850 N
X2 &
FX
240W
& 5
0W
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m26
DAMP LOCATION
• High Performance Compact Fluorescent Lamp Options:• 40 Watt (2G11) High Performance Compact Fluorescent• 50 Watt (2G11) High Performance Compact Fluorescent
• Voltage Options:• 120 Volt• 277 Volt
• Ballast Options:• High Power Factor (40 watt only)• Electronic• Dimming
• 24" On Center Spacing
40 & 50 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2850 NX2/FX2™
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
3³⁄₈"
3¹⁄₈"
2⁵⁄₈" without bracket
72"
48"
24"
Minimum Cove Parametersinside radius 66"outside radius 72"
2850linearfixture
NX2seamless straightlamp up or down
FX2field curvablelamp up or down
4040 wattcompactfluorescent
5050 wattcompactfluorescent
1120 volt
2277 volt
Hhigh power factor(40 watt, 48" & 24" only)
Eelectronic
Ddimming
7272" length (3 lamps, 40 watt only)
4848" length (2 lamps)
2424" length(1 lamp)
Allow 4" for lamp overhang and removal
![Page 27: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/27.jpg)
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
Ordering Formatchoose one from each category
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 27
DAMP LOCATION
• High Performance Compact Fluorescent Lamp Options:• 40 Watt (2G11) High Performance Compact Fluorescent• 50 Watt (2G11) High Performance Compact Fluorescent
• Voltage Options:• 120 Volt• 277 Volt
• Ballast Options:• High Power Factor (40 watt only)• Electronic• Dimming
• 24" On Center Spacing
2850 N
X2S &
FX
2S
40W
& 5
0W
40 & 50 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2850 NX2S/FX2S™
72"
48"
24"
3³⁄₈"
3¹⁄₈"
2⁵⁄₈" without bracketAllow 4" for lamp overhang and removal
Minimum Cove ParametersLamp Out
inside radius 67"outside radius 72"
Lamp Ininside radius 65"outside radius 70"
2850linearfixture
NX2Sseamless straightlamp in or out
FX2Sfield curvablelamp in or out
4040 wattcompactfluorescent
5050 wattcompactfluorescent
1120 volt
2277 volt
Hhigh power factor(40 watt, 48" & 24" only)
Eelectronic
Ddimming
7272" length(3 lamps, 40 watt only)
4848" length(2 lamps)
2424" length(1 lamp)
![Page 28: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/28.jpg)
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
Ordering Formatchoose one from each category
2850 N
X2 &
FX
239W
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m28
DAMP LOCATION
• 39 Watt (2G11) High Performance Compact Fluorescent Lamp
• Voltage Options:• 120 Volt• 277 Volt
• Ballast Options:• High Power Factor• Electronic• Dimming
• 18" On Center Spacing
39 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2850 NX2/FX2™
3³⁄₈"
3¹⁄₈"
Minimum Cove Parametersinside radius 49"outside radius 55"
54"
36"
18"
Allow 4" for lamp overhang and removal
2850linearfixture
NX2seamless straightlamp up or down
FX2field curvablelamp up or down
3939 wattcompactfluorescent
1120 volt
2277 volt
Hhigh power factor(36" and 18" only)
Eelectronic
Ddimming
5454" length(3 lamps)
3636" length(2 lamps)
1818" length(1 lamp)
2⁵⁄₈" without bracket
![Page 29: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/29.jpg)
Ordering Formatchoose one from each category
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 29
DAMP LOCATION
• 39 Watt (2G11) High Performance Compact Fluorescent Lamp
• Voltage Options:• 120 Volt• 277 Volt
• Ballast Options:• High Power Factor• Electronic• Dimming
• 18" On Center Spacing
2850 N
X2S &
FX
2S
39W
39 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2850 NX2S/FX2S™
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
3³⁄₈"
3¹⁄₈"
54"
36"
18"
2850linearfixture
NX2Sseamless straightlamp in or out
FX2Sfield curvablelamp in or out
3939 wattcompactfluorescent
1120 volt
2277 volt
Hhigh power factor(36" and 18" only)
Eelectronic
Ddimming
5454" length (3 lamps)
3636" length (2 lamps)
1818" length (1 lamp)
Allow 4" for lamp overhang and removal
Minimum Cove ParametersLamp Out
inside radius 47"outside radius 53"
Lamp Ininside radius 50"outside radius 56"
2⁵⁄₈" without bracket
![Page 30: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/30.jpg)
Ordering Formatchoose one from each category
2850 N
X2 &
FX
2
18W
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m30
DAMP LOCATION
• 18 Watt (2G11) High Performance Compact Fluorescent Lamp (rapid start)
• Voltage Options:• 120 Volt• 277 Volt
• Ballast Options:• High Power Factor• Electronic
• 12" On Center Spacing
18 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2850 NX2/FX2™
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
12"
24"
48"
Minimum Cove Parametersinside radius 32"outside radius 38"
3³⁄₈"
3¹⁄₈"
2⁵⁄₈" without bracket
2850linearfixture
NX2seamless straightlamp up or down
FX2field curvablelamp up or down
1818 wattcompactfluorescent(rapid start)
1120 volt
2277 volt
Hhigh power factor
Eelectronic
4848" length(4 lamps)
2424" length(2 lamps)
1212" length(1 lamp)
Allow 4" for lamp overhang and removal
![Page 31: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/31.jpg)
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
Ordering Formatchoose one from each category
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 31
DAMP LOCATION
2850 N
X2S &
FX
2S
18W3³⁄₈"
3¹⁄₈"
Minimum Cove ParametersLamp Out
inside radius 33"outside radius 38"
Lamp Ininside radius 29"outside radius 36"
48"
24"
12"
2850linearfixture
NX2Sseamless straightlamp in or out
FX2Sfield curvablelamp in or out
1818 wattcompactfluorescent(rapid start)
1120 volt
2277 volt
Hhigh power factor
Eelectronic
4848" length(4 lamps)
2424" length(2 lamps)
1212" length(1 lamp)
2850 NX2S/FX2S™
• 18 Watt (2G11) High Performance Compact Fluorescent Lamp (rapid start)
• Voltage Options:• 120 Volt• 277 Volt
• Ballast Options:• High Power Factor• Electronic
• 12" On Center Spacing
18 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2⁵⁄₈" without bracketAllow 4" for lamp overhang and removal
![Page 32: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/32.jpg)
32
THE 2801 COMPACT FLUORESCENT
SERIES FEATURES TWIN TUBE, COLOR
CORRECTED 9W AND 13W COMPACT
FLUORESCENT LAMPS ON OUR FIELD
CURVABLE SATIN ANODIZED ALUMINUM
BODY. THESE FIXTURES CAN BE CURVED
DOWN TO A TIGHT 19¹ ⁄ ₂" RADIUS TO
MEET YOUR MOST CHALLENGING JOB
REQUIREMENTS.
MULTIPLE LENGTHS ARE AVAILABLE IN
OUR PATENTED SEAMLESS STRAIGHT TO
FIELD CURVABLE SYSTEM FOR COST
EFFECTIVE INSTALLAT IONS. THESE UNITS
CAN BE COMBINED TO EVENLY ILLUMINATE
ARCHITECTURAL COVES, SHELVES AND
VALANCES WHILE EL IMINAT ING DARK
CORNERS, DARK ENDS AND SOCKET
SHADOWS. SOCKETS SWIVEL FOR EASY
RELAMPING IN ANY APPLICAT ION.
The 2801 Series
These products protected by one or more of the following U.S. patents 5,448,460, 5,221,139 and5,452,187. Other patents pending.
2801 NX2 9 WATT
2801 FX2S 9 WATTLamps fac ing out
![Page 33: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/33.jpg)
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 33
2801 FX2 9 WATTLamps fac ing up
TABLE OF CONTENTS
2801 NX2 & FX2 9W/13W. . . . . . . . . page 34
2801 NX2S & FX2S 9W/13W . . . . . . page 35
Compact Fluorescent Lamps . . . . . . page 46
Lumen Output Chart. . . . . . . . . . . . . page 11
![Page 34: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/34.jpg)
Ordering Formatchoose one from each category
2801
NX
2 &
FX
2
9W
& 1
3W
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m34
DAMP LOCATION
• Compact Fluorescent Lamp Options:• 9 Watt (G23) Compact Fluorescent• 13 Watt (GX23) Compact Fluorescent
• Voltage Options:• 120 Volt• 277 Volt
• High Power Factor Ballast
• 8" On Center Spacing
9 & 13 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2801 NX2/FX2™
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
3³⁄₈"
3¹⁄₈"8"
48"
24"
Minimum Cove Parametersinside radius 23¹⁄₂"outside radius 28¹⁄₂"
2801linearfixture
NX2seamless straightlamp up or down
FX2field curvablelamp up or down
99 wattcompactfluorescent
1313 wattcompactfluorescent
1120 volt
2277 volt
Hhigh power factor
4848" length(6 lamps)
2424" length(3 lamps)
88" length(1 lamp)
2⁵⁄₈" without bracket Allow 4" for lamp overhang and removal
![Page 35: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/35.jpg)
Ordering Formatchoose one from each category
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 35
DAMP LOCATION
• Compact Fluorescent Lamp Options:• 9 Watt (G23) Compact Fluorescent• 13 Watt (GX23) Compact Fluorescent
• Voltage Options:• 120 Volt• 277 Volt
• High Power Factor Ballast
• 8" On Center Spacing
2801 N
X2S &
FX
2S
9W
& 13
W
9 & 13 WATT SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2801 NX2S/FX2S™
Allow 4" for lamp overhang and removal
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
8"
48"
24"
Minimum Cove ParametersLamp Out
inside radius 21¹⁄₂"outside radius 26"
Lamp In (9 watt only)inside radius 19¹⁄₂"outside radius 24"
3³⁄₈"
3¹⁄₈"
2⁵⁄₈" without bracket
2801linearfixture
NX2Sseamless straightlamp in or out
FX2Sfield curvablelamp in or out
99 wattcompactfluorescent
1313 wattcompactfluorescent(lamp out only)
1120 volt
2277 volt
Hhigh power factor
4848" length(6 lamps)
2424" length(3 lamps)
88" length(1 lamp)
![Page 36: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/36.jpg)
THE 2880 COMPACT FLUORESCENT
SERIES IS DESIGNED TO BE LAMP
COMPATIBLE WITH SPECIF ICAT ION GRADE
DOWNLIGHTS BY FEATURING 26W QUAD
AND 32W AND 42W HEX COMPACT
FLUORESCENT LAMPS IN A L INEAR
CONFIGURATION. IDEALLY SUITED TO
LARGE OPEN SPACES THAT REQUIRE VERY
HIGH LEVELS OF ILLUMINATION, THESE
F IXTURES ARE FIELD CURVABLE DOWN
TO A TIGHT 23¹ � ₂" RADIUS.
The 2880 Series
These products protected by one or more of the following U.S. patents 5,448,460, 5,221,139 and5,452,187. Other patents pending.
2880 FX2 26 WATTLamps fac ing up
36
2880 NX2S 32 WATT
![Page 37: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/37.jpg)
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 37
TABLE OF CONTENTS
2880 NX2 & FX2 26W. . . . . . . . . . . . page 38
2880 NX2S & FX2S 26W . . . . . . . . . page 39
2880 NX2 & FX2 32W/42W. . . . . . . . page 40
2880 NX2S & FX2S 32W/42W . . . . . page 41
Compact Fluorescent Lamps . . . . . . page 46
Lumen Output Chart. . . . . . . . . . . . . page 11
2880 FX2 26 WATTLamps fac ing up
2880 FX2S 42 WATTLamps fac ing out
![Page 38: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/38.jpg)
Ordering Formatchoose one from each category
2880 N
X2 &
FX
2
26W
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m38
DAMP LOCATION
26 WATT QUAD SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2880 NX2/FX2™
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
8"
48"
24"
3⁹⁄₁₆"
3¹⁄₈"
Minimum Cove Parametersinside radius 23¹⁄₂"outside radius 28¹⁄₂"
2880linearfixture
NX2seamless straightlamp up or down
FX2field curvablelamp up or down
2626 watt quadcompact fluorescent(G24d-3)
2626 watt quadcompact fluorescent(G24q-3)
1120 volt
2277 volt
1120 volt
2277 volt
Hhigh power factor
Eelectronic
4848" length(6 lamps)
2424" length (3 lamps)
88" length(1 lamp)
• Lamp Compatible with Specification Grade Compact Fluorescent Downlights
• High Performance Compact Fluorescent Lamp Options:• 26 Watt Quad (G24d-3) High Performance Compact Fluorescent• 26 Watt Quad (G24q-3) High Performance Compact Fluorescent
• Voltage Options:• 120 Volt• 277 Volt
• Ballast Options:• High Power Factor• Electronic
• 8" On Center Spacing
Allow 4" for lamp overhang and removal2⁵⁄₈" without bracket
![Page 39: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/39.jpg)
Ordering Formatchoose one from each category
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 39
DAMP LOCATION
• Lamp Compatible with Specification Grade Compact Fluorescent Downlights
• High Performance Compact Fluorescent Lamp Options:• 26 Watt Quad (G24d-3) High Performance Compact Fluorescent• 26 Watt Quad (G24q-3) High Performance Compact Fluorescent
• Voltage Options:• 120 Volt• 277 Volt
• Ballast Options:• High Power Factor• Electronic
• 8" On Center Spacing
2880 N
X2S &
FX
2S
26W
26 WATT QUAD SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2880 NX2S/FX2S™
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
3⁹⁄₁₆"
3¹⁄₈"
Minimum Cove ParametersLamp Out ONLY
inside radius 21¹⁄₂"outside radius 26"
8"
48"
24"
2880linearfixture
NX2Sseamless straightlamp out only
FX2Sfield curvablelamp out only
2626 watt quadcompact fluorescent(G24d-3)
2626 watt quadcompact fluorescent(G24q-3)
1120 volt
2277 volt
1120 volt
2277 volt
Hhigh power factor
Eelectronic
4848" length(6 lamps)
2424" length(3 lamps)
88" length(1 lamp)
2⁵⁄₈" without bracketAllow 4" for lamp overhang and removal
![Page 40: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/40.jpg)
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
Ordering Formatchoose one from each category
2880 N
X2 &
FX
232W
& 4
2W
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m40
DAMP LOCATION
32 & 42 WATT HEX SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2880 NX2/FX2™
2⁵⁄₈" without bracket
8"
48"
24"
Allow 4" for lamp overhang and removal
2880linearfixture
NX2seamless straightlamp up or down
FX2field curvablelamp up or down
3232 watt hex compactfluorescent (G24q-3)
4242 watt hex compactfluorescent (G24q-4)
1120 volt
2277 volt
Eelectronic
4848" length(6 lamps)
2424" length(3 lamps)
88" length(1 lamp)
• Lamp Compatible with Specification Grade Compact Fluorescent Downlights
• High Performance Compact Fluorescent Lamp Options:• 32 Watt Hex (G24q-3) High Performance Compact Fluorescent Lamp• 42 Watt Hex (G24q-4) High Performance Compact Fluorescent Lamp
• Voltage Options:• 120 Volt• 277 Volt
• Electronic Ballast
• 8" On Center Spacing
Minimum Cove Parametersinside radius 23¹⁄₂"outside radius 28¹⁄₂"
3⁷⁄₈"
3¹⁄₈"
![Page 41: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/41.jpg)
Ordering Formatchoose one from each category
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 41
DAMP LOCATION
• Lamp Compatible with Specification Grade Compact Fluorescent Downlights
• High Performance Compact Fluorescent Lamp Options:• 32 Watt Hex (G24q-3) High Performance Compact Fluorescent Lamp• 42 Watt Hex (G24q-4) High Performance Compact Fluorescent Lamp
• Voltage Options:• 120 Volt• 277 Volt
• Electronic Ballast
• 8" On Center Spacing
2880 N
X2S &
FX
2S
32W
& 4
2W
32 & 42 WATT HEX SEAMLESS STRAIGHT AND FIELD CURVABLE SYSTEM
2880 NX2S/FX2S™
Allow 4" for lamp overhang and removal
3⁷⁄₈"
3¹⁄₈"
2⁵⁄₈" without bracket
Minimum Cove ParametersLamp Out ONLY
inside radius 21¹⁄₂"outside radius 27"
8"
48"
24"
2880linearfixture
NX2Sseamless straightlamp out only
FX2Sfield curvablelamp out only
3232 watt hex compactfluorescent (G24q-3)
4242 watt hex compactfluorescent (G24q-4)
1120 volt
2277 volt
Eelectronic
4848" length(6 lamps)
2424" length(3 lamps)
88" length(1 lamp)
SERIES LAMPCONFIGURATION
LAMP VOLTAGE BALLAST LENGTH
![Page 42: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/42.jpg)
42
THE 2862 COMPACT FLUORESCENT LOW
PROFILE MODULES FEATURE 9W, 13W,
18W, 39W, 40W AND 50W COLOR
CORRECTED LAMPS ON SMALL, LOW
PROFILE REMOTE OR INTEGRAL BALLAST
HOUSINGS. SUITABLE FOR THOSE UNUSUAL
ARCHITECTURAL POCKETS WHICH REQUIRE
HIGH ILLUMINATION FROM MINIATURIZED
FLUORESCENT SOURCES, THE 2862
SERIES OFFERS L IGHTING DESIGN
FLEXIB IL ITY WITH A VARIETY OF HIGH
POWER FACTOR, NORMAL POWER FACTOR,
DIMMING OR ELECTRONIC BALLASTS.
The 2862 SeriesLow Profile Modules
2862 40/50 WATT REMOTE MODULE
![Page 43: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/43.jpg)
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 43
2862 13 WATT MODULE
2862 18 WATT REMOTE
2862 39 WATT REMOTE
2862 9 WATT MODULE
![Page 44: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/44.jpg)
Ordering Formatchoose one from each category
2862
9W
& 1
3W
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m44
DAMP LOCATION
• Compact Fluorescent Lamp Options:• 9 Watt (G23) Compact Fluorescent• 13 Watt (GX23) Compact Fluorescent
• 120 Volt
• Ballast Options:• Normal Power Factor• High Power Factor
9 & 13 WATT LOW PROFILE MODULE
2862 Low Profile Modules
2"
2¹⁄₈"¹⁄₄"
A
¹⁄₄"
B
2"
2¹⁄₈"
1"
Allow 1" for lamp removal
2862 9 Watt Fixture Dimensions
Ballast A B
Normal Power Factor 10" 3"High Power Factor 12" 4¹⁄₂"
A
¹⁄₄"
B
2"
2¹⁄₈"
1"
2862 13 Watt Fixture Dimensions
Allow 1" for lamp removal
Ballast A B
Normal Power Factor 10⁵⁄₈" 3"High Power Factor 12¹⁄₈" 4¹⁄₂"
SERIES
2862module
LAMP
99 watt compact fluorescent
1313 watt compact fluorescent
1120 volt
BALLAST
Nnormal power factor
Hhigh power factor
VOLTAGE
![Page 45: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/45.jpg)
Ordering Formatchoose one from each category
BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m 45
DAMP LOCATION
28
62
18W
, 39W, 40W
& 5
0W
18, 39, 40 & 50 WATT LOW PROFILE INTEGRAL & REMOTE MODULE
2862 Low Profile Modules
³⁄₄"2"
A
2"
A
12" ³⁄₄"
2"
3"
2"
• High Performance Compact Fluorescent Lamp Options:• 18 Watt (2G11) High Performance Compact Fluorescent (rapid start)• 39 Watt (2G11) High Performance Compact Fluorescent• 40 Watt (2G11) High Performance Compact Fluorescent• 50 Watt (2G11) High Performance Compact Fluorescent
• Voltage Options:• 120 Volt• 277 Volt
• Remote and Integral Ballast Options:• High Power Factor (18, 39 and 40 watt only)• Electronic• Dimming (39, 40 and 50 watt only)
• Remote Ballast Box Constructed of White Formed Aluminum (2" x 3" x 12")
3"3"
Integral Fixture Dimensions
Lamp A18 watt 24"39 watt 30"40 watt 36"50 watt 36"
Remote Fixture Dimensions
Lamp A18 watt 14"39 watt 20"40 watt 26"50 watt 26"
SERIES LAMP BALLASTBALLASTMOUNT
VOLTAGE
2862module
1818 watt compact fluorescent(rapid start)
3939 watt compact fluorescent
4040 watt compact fluorescent
5050 watt compact fluorescent
1120 volt
2277 volt
Hhigh power factor(18, 39 & 40 watt only)
Eelectronic
Ddimming(39, 40 & 50 watt only)
Rremote
Iintegral
![Page 46: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/46.jpg)
46
Compact Fluorescent Lamps
2801 SERIES
• CF9/35K 9W Twin G23 base Compact Fluorescent 3500°K
• CF13/35K 13W Twin GX23 base Compact Fluorescent 3500°K
2850 SERIES
• CF18/35K/RS 18W Twin 2G11 base Compact Fluorescent 3500°K Rapid Start
• CF39/35K 39W Twin 2G11 base Compact Fluorescent 3500°K
• CF40/35K 40W Twin 2G11 base Compact Fluorescent 3500°K
• CF50/35K 50W Twin 2G11 base Compact Fluorescent 3500°K
2855 SERIES
• CF9/35K 9W Twin G23 base Compact Fluorescent 3500°K
• CF13/35K 13W Twin GX23 base Compact Fluorescent 3500°K
• CF18/35K/RS 18W Twin 2G11 base Compact Fluorescent 3500°K Rapid Start
• CF39/35K 39W Twin 2G11 base Compact Fluorescent 3500°K
• CF40/35K 40W Twin 2G11 base Compact Fluorescent 3500°K
• CF50/35K 50W Twin 2G11 base Compact Fluorescent 3500°K
2862 SERIES
• CF9/35K 9W Twin G23 base Compact Fluorescent 3500°K
• CF13/35K 13W Twin GX23 base Compact Fluorescent 3500°K
• CF18/35K/RS 18W Twin 2G11 base Compact Fluorescent 3500°K Rapid Start
• CF39/35K 39W Twin 2G11 base Compact Fluorescent 3500°K
• CF40/35K 40W Twin 2G11 base Compact Fluorescent 3500°K
• CF50/35K 50W Twin 2G11 base Compact Fluorescent 3500°K
2880 SERIES
• CF26Q/35K/2 26W Quad G24d-3 base Compact Fluorescent 3500°K
• CF26Q/35K/4 26W Quad G24q-3 base Compact Fluorescent 3500°K
• CF32H/35K/4 32W Hex GX24q-3 base Compact Fluorescent 3500°K
• CF42H/35K/4 42W Hex GX24q-4 base Compact Fluorescent 3500°K
LU M E N OU T P U T CH A R T I S L O C AT E D O N PA G E 11
2850 and 2855 installations where the lampis in the down position may require an auxiliarylamp clip that snaps over standard lamp clip.Please order P-2013-01-00 (one required per lamp)
![Page 47: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/47.jpg)
Just a word about ballasts…BE L F E R W O R K S C L O S E LY W I T H B A L L A S T M A N U FA C T U R E R S T O T E S T A N D S E L E C T
Q U A L I T Y B A L L A S T S I N O R D E R T O E N S U R E T H E M O S T R E L I A B L E F I X T U R E O P E R AT I O N.
TH E R E A R E F O U R D I F F E R E N T T Y P E S O F B A L L A S T S U T I L I Z E D I N O U R F L U O R E S C E N T P R O D U C T S.
NORMAL POWER FACTOR (N OR NPF) BALLASTS:Quality Normal Power Factor ballasts are primarily used in installations where minimum space isavailable.
HIGH POWER FACTOR (H OR HPF) BALLASTS:Our standard High Power Factor ballasts carry a Class A sound rating and offer a Power Factorrating of .90 or better. High Power Factor ballasts consume less energy than Normal Power Factor(NPF) ballasts due to capacitive power factor correction.
ELECTRONIC (E OR ELB) BALLASTS:Our standard Electronic ballasts also carry a Class A sound rating and are quieter and lessexpensive to operate than High Power Factor (HPF) or Normal Power Factor (NPF) ballasts.Electronic ballasts are able to start lamps at lower temperatures and are more efficient than HighPower Factor ballasts due to high frequency operation.
DIMMING (D OR DIM) BALLASTS:Belfer is an authorized Lutron Dimming ballast OEM. Lutron provides one of the most popular andreliable Dimming ballasts in the industry. These ballasts provide a dimming range of 100% to10%. Although Lutron Dimming ballasts are standard in many of our products, other qualitydimming sources are available. Please consult our sales department for more information.
47BELFER LIGHTING FOR ARCHITECTURE
T E L : ( 7 3 2 ) 4 9 3 - 2 6 6 6 . FA X : ( 7 3 2 ) 4 9 3 - 2 9 4 1 . w w w.b e l f e r.c o m
SUBSTITUTION OF BALLASTS:Based on our quality assured testing of ballasts, unless specified, we select ballasts at ourdiscretion. Of course, the specification may indicate a particular type or brand of ballast suitablefor the installation. This may adjust costs and lead times for our products. At the customersrequest, we will also install ballasts supplied to us by an authorized ballast distributor. Ifrequested, we may also ship fluorescent products without ballasts.
BALLAST WARRANTIES:At Belfer, we supply the best grade of ballasts from top rated manufacturers. Ballasts are coveredby warranties issued by the ballast manufacturer. This warranty is passed through to ourcustomer. There are varying terms and conditions that may apply to your specific installation.Copies of respective ballast warranties are available upon request.
REMOTE BALLAST BOXES:Belfer Remote Ballast Boxes are constructed of white formed aluminum for superior heat transferand corrosion resistance. Ballast Box sizes are listed on each product page (where applicable).
![Page 48: OOLS FOR THE L IGHTING P ROFESSIONALbelfer.com/wp-content/uploads/2019/02/Belfer-Comp-Fluor.pdf · With the advent of compact linear fluorescent technology in the late 1970s, Belfer](https://reader033.vdocuments.site/reader033/viewer/2022042810/5f9d48a071469b5f9b3df5b1/html5/thumbnails/48.jpg)
COVER & PAGE 2 & 3AMERICAN FOREST & PAPER ASSOCIATION
LIGHTING DESIGN: CANDACE KLING, IALD, C. M. KLING AND ASSOCIATES INC.ARCHITECT: GREENWALL GOETZ ARCHITECTS, PC.PHOTOGRAPHER: DAVID PATTERSON
PAGE 4WHITMAN CORPORATION HEADQUARTERS
ARCHITECT/DESIGN: HAGUE-RICHARDS ASSOCIATES LTD.PHOTOGRAPHER: HEDRICH-BLESSING, LTD.
PAGE 5 & PAGE 36JOHN L. TISHMAN AUDITORIUM, NEW SCHOOL FOR SOCIAL RESEARCH
LIGHTING DESIGN: FRANK KELLY
ARCHITECT/INTERIOR DESIGN: ROLF OLHAUSEN, BARBARA SPANDORF ARCHITECTS, INC.PHOTOGRAPHER: BRIAN ROSE
PAGE 9DELOITTE & TOUCHE ENGINEERING DRAWING
LIGHTING DESIGN: BARBARA HORTON, CAROLYN KNOWLTON, HORTON-LEES LIGHTING DESIGN
PAGE 10AMERICAN AIRLINES ADMIRALS CLUB
PHOTOGRAPHER: PETER PAIGE
PAGE 14HARCOURT GENERAL HEADQUARTERS
LIGHTING DESIGN: RIPMAN LIGHTING CONSULTANTS
ARCHITECT: THE STUBBINS ASSOCIATES
PHOTOGRAPHER: PETER LEWITT ARCHITECTURAL PHOTOGRAPHY
PAGE 24XEROX KNOWLEDGE SHARING CENTER
LIGHTING DESIGN: ANN KALE ASSOCIATES
ARCHITECT: HIGHLAND ASSOCIATES
INTERIOR DESIGN: IDEO SAN FRANCISCO
PHOTOGRAPHER: DAVID JOSEPH
PAGE 32EMANUEL/ EMANUEL UNGARO
LIGHTING DESIGN: DAVID APFEL
PHOTOGRAPHER: PAUL WARCHOL
PAGE 42CORNELL UNIVERSITY, JOHNSON SCHOOL OF MANAGEMENT, SAGE HALL
ARCHITECT: HILLIER & ASSOCIATES
PHOTOGRAPHER: ROBERT BARKER
P.O. Box 2079Ocean, New Jersey 07712TEL: (732) 493-2666FAX: (732) 493-2941Toll Free in Canada: 1-800-726-5759www.belfer.com
LIGHTING FOR ARCHITECTURE
© 2000 BELFER. ALL RIGHTS RESERVED