ONLINE UPS
A11J
2
Online UPS
A11J ネットワーク対応 19インチラック対応
常時インバータ給電
Network Support
ネットワーク対応 19インチラック対応
常時インバータ給電
19-inch Rack Mountable
Battery backup time
Battery backup time
5(4.5)
10(9)
15(13.5)
20(18)
5(4.5)
10(9)
15(13.5)
20(17)
200 [Single-phase 2-wire]
100 [Single-phase 2-wire] or
200 [Single-phase 2-wire]5
(4.5)10(9)
200 [Single-phase 2-wire]
Input AC V Output AC V Output capacity kVA(kW)
Input AC V Output AC V Output capacity kVA(kW)
UL / CE certified models
Mounting examples
100 [Single-phase 2-wire] or
100/200 [Single-phase 3-wire]
200 [Single-phase 2-wire]
200 [Single-phase 2-wire]
100 [Single-phase 2-wire] or
100/200 [Single-phase 3-wire]
180min.60min.30min.45min.35min.25min.15min.
10min.5min.
*1 *2
Battery selection options *3
*1 3U type with a load factor of 0.8.*2 4U type with a load factor of 0.75.
*3 There are some restrictions on the combination with the installation method and output capacity.
Battery runtime can be extended through the addition of optional battery boxes. Contact us for details.
* load factor of 0.8.5min.
*
EIA standard19-inch rack mounting.Optional rack support rails are available.
Vertical mountingYou can change the orientation of
the front LCD display panel.
See "Dimensions" for applicable
models. →p.12 to 17
3
*If deterioration in battery performance is detected during the battery operation test, normal operation is resumed.
Comm
ercial pow
er supply
Battery Battery
Start operation test
Return to normal operation
Device
Comm
ercial pow
er supply
Normal operation Check battery power supply
Periodiccheck
Periodiccheck
RectifierBooster Inverter
Device
RectifierBooster Inverter
● High 93% efficiency. (with the 5 kVA single unit model)
● Reduces running cost and helps conserve energy.
● You can connect up to four 5 kVA UPS units in parallel to expand capacity up to 20 kVA.
● Periodic automatic battery operation tests ensure reliable
operation during a power outage.
● Battery operations tests do not cause momentary power
outages.
* You can select the frequency of the battery operation test.
Features
High Efficiency
Expandable Capacity
High Reliability
5 kVA/4.5 kW 10 kVA/9 kW 15 kVA/13.5 kW 20 kVA/18 kW
5 kVA/4.5 kW 10 kVA/9 kW 15 kVA/13.5 kW
Single unit/parallel operation (N-unit setting)
Parallel redundant operation (N+1-unit setting)
UL/CE certified UPS unit:17 kW
Collection unit Collection unit Collection unit
Space-saving Design
● The compact 3U size of the 5 kVA UPS unit (for 5-minute backup) allows you to mount it in an EIA 19-inch rack.
3U size(130 mm)(5.12 inch)
Efficiency of
Device
93%Commercial
power supply
4
Easy Maintenance
● Maintenance can be easily performed by replacing the battery or inverter from the front.
● A built-in maintenance bypass allows maintenance to be performed while
commercial power is being supplied. In parallel redundant configurations,
maintenance can be performed while inverter power is being supplied. *The maintenance bypass circuit is not available for UL/CE certified models.
Able to Supply Power to High Power Factor Devices
● 0.9 load power factor enables the unit to supply power to high power factor devices such as servers.
Network Options
Features
Output capacity of 5 kVA
Output capacity of 20 kVA
4.5 kW max.
18 kW max.UL / CE certified unit : 17 kW max.
* See our web site for the most recent list of supported operating systems.
■ LAN interface card ■ SANUPS SOFTWARE
When an optional card is installed in the slot on the back, power status is continually monitored and reported, enabling quick countermeasures to be taken when power troubles occur.The system administrator can also be notified of power troubles by email.
Reliabi l ity and management of whole systems including network and servers is improved. Information about the UPS can be reported to the system administrator, and various settings regarding power troubles can be made.
for Windowsfor Multiple OS / For Windows, Unix and Linux
Battery pack Inverter module
5
20 kVA Front [model No.: A11J203S****] shown here.
20 kVA Back [model No.: A11J203S****] shown here. 5 kVA Back [model No.: A11J502****T] shown here.
5 kVA UL/CE Certified Unit Back [model No.: A11J502****TU] shown here.
5 kVA Front [model No.: A11J502****T/N] shown here.
Inverter ON / STAND BYSwitch
Input LED
Warning LED
InverterON / STAND BY Switch
Output LED
Backup LEDInput LED
LCD
Menu Operation Switch
Output LED
Alarm LED
Input Switch
Output Receptacle(IEC-C13×2)
Output Receptacle Breaker(for IEC-C13)
Output Receptacle(NEMA L6-30R)
I/O Terminal Block
Maintenance Bypass Switch
Optional Battery Connector
Output Receptacle Breaker(for L6-30R)
Cooling Fan
Optional Slot
External ControlTerminal(EPO and Remote ON/OFF)
Optional Card Interface
ContactSignal Interface
PC Interface
Unit-to-Unit Interface
I/O Terminal Block
Cooling Fan
I/O Connector
I/O Connectorx 4 Sets
I/O Terminal Block
I/O Terminal Block
Optional BatteryConnector
Cooling Fan
Unit-to-Unit Interface
PC Interface
Contact Signal Interface
Optional Card Interface
I/O Connectorx 4 Sets
Maintenance BypassSwitch (Inside Cover)* Not available for UL/CE certified units
I/O Connector
Optional Slot
Optional Slot
External ControlTerminal(EPO and Remote ON/OFF)
PC Interface
Contact Signal Interface
Optional Card Interface
External ControlTerminal(EPO and Remote ON/OFF)
Cooling Fan
Unit-to-Unit Interface
20 kVA UL/CE Certified Unit Back [model No.: A11J203S****U] shown here.
Optional Slot
External ControlTerminal
Optional Card Interface
ContactSignal Interface
PC Interface
Unit-to-Unit Interface
Terminal Block Type
Terminal Block Type
External View
6
Specification
Model Rack mounting type
3U A11J502A002T A11J502A002N A11J502SA002RM A11J502WA001RM
4U A11J502A002T4U A11J502A002N4U A11J502SA002RM-4U A11J502WA001RM-4U
Stand-alone type 3U A11J502A002T A11J502A002N A11J502SA002 A11J502WA001
4U A11J502A002T4U A11J502A002N4U A11J502SA002-4U A11J502WA001-4U
Rated output capacity(Apparent power / Active power)
N unit setting 5 kVA / 4.5 kWN+1 unit setting —
System Power supply system True online power supply synchronized with commercial power sourceCooling system Forced air coolingInverter system High-frequency PWM
IEC standard (UPS classification) VFI-SS-111ACinput
Number of phase Single-phase 2-wireRated voltage 200 V, 208 V, 220 V, 230 V, 240 V (User settable. Factory setting: 200 V) 100 V or 200 V (Swith at terminal Factory setting: 100 V)Acceptable voltage range *1 -40% to +15% -35% to +15%Rated frequency 50Hz / 60Hz (Selectable Auto-detect or Constant frequency*2 Factory setting: Auto-detect)Max. capacity 5.5 kVA 6 kVA max.Power factor 0.95 min. (At rated input voltage and input voltage distorsion rate under 1%)
ACoutput
Number of phase Single-phase 2-wire Single-phase 2-wire or Single-phase 3-wireRated voltage (same as input) 200 V, 208 V, 220 V, 230 V, 240 V (Factory setting: 200 V) 100 V (2 W) or 100 V / 200 V (3 W)Voltage accuracy Within ± 2% of rated voltage Within ± 5% of rated voltageRated frequency (same as input) 50Hz / 60HzFrequency range *3 On normal operation Rated frequency Within ± 1, 3, 5% (Factory setting: 3%)
On battery operation Within ± 0.5% Voltage waveform Sine waveDistortion factor of voltage Within 3% / 8% (Linear load / Rectifier load at rated output) Within 3% (Linear load at rated output)Transientvoltagevariation
Rapid load factor change Within ± 5% (0 ⇔ 100% rapid change) Within ± 5% (10 ⇔ 100% rapid change)Power outage / recovery Within ± 5% Rapid input voltage change Within ± 5% (± 10% rapid change)
Load power factor 0.9 lag (acceptable range 0.7 (lag) to 1.0)Overcurrent protection N unit 110% and over (Automatic swith to bypass *4) 104% and over (Automatic swith to bypass *4)
N+1 unit —Overloadcapacity
Inverter N unit 110% (1 min) / 118% (inst.) 104% (1 min) / 112% (inst.)N+1 unit —
Bypass N unit 200% (30 s) / 800% (2 cycles)N+1 unit —
Battery Type Small-sized sealed lead-acid batteryComposition 16 unit (12 V / 1 unit)Rated capacity 3U 5 Ah / unit
4U 9 Ah / unitBattery runtime 3U 5 min (Ambient Temp. of 25ºC, Load power factor 0.8 , Default)
4U 10 min (Ambient Temp. of 25ºC, Load power factor 0.75 , Default)Input leak current 4 mA max. 12 mA max.Acoustic noise (At 1m (40 in) from the front of unit) 45 dB max. 50 dB max.Nominal heat dissipation (at rated output after full recharged) 339 W 350 W 733 WEnvironment Operating temperature 0ºC to 40ºC
Relative humidity 20% to 90%(Non-condensing)I/O Connector / Wiring Wire, etc. *5
Input Connector M6 NEMA L6-30P M8 M8Input wire 8mm2 — 8 mm2 8 mm2 (200 V), 22 mm2 (100 V)Output Connector M6
NEMA L6-30R ×1IEC-C13 ×2
NEMA L6-30R ×2NEMA L6-20R ×2
M8NEMA L6-30R ×4
M8
Output wire 8 mm2 — 8 mm2 8 mm2 (size AA), 14 mm2 (size C)Grounding wire 5.5 mm2 — 8 mm2
Input breaker capacity 40 A min. 30 A min. 40 A min. 40 A (200 V), 80 A (100 V)
Type Power distribution unit (20 kVA) AC input AC output Model*2 Battery runtime (min)
Single / Terminal block type — Single-phase 2-wire 200V Single-phase 2-wire 200V A11J502A0□2T 5, 15, 25, 30, 35, 45, 60, 180*1
Single / NEMA plug type — Single-phase 2-wire 200V Single-phase 2-wire 200V A11J502A0□2N 5, 15, 25, 30, 35, 45, 60, 180*1
Stand-alone type — Single-phase 2-wire 100V or Single-phase 2-wire 200V
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J502WA0□1 5, 30, 60, 180
Single-phase 2-wire 200V Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J502WA0□2 5, 30, 60, 180
*3 Single-phase 2-wire 200V Single-phase 2-wire 200V A11J502SA0□2 5, 30, 60, 180
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J502WA0□2Z 5, 30, 60, 180
Stand-alone type Output receptacle *3 Single-phase 2-wire 200V Single-phase 3-wire 100/200V A11J502WA0□2DX 5, 30, 60, 180
Rack mounting type — Single-phase 2-wire 100V or Single-phase 2-wire 200V
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J502WA001RM 5, 15, 25, 35, 45
Single-phase 2-wire 200V Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J502WA002RM 5, 15, 25, 35, 45
*3 Single-phase 2-wire 200V Single-phase 2-wire 200V A11J502SA002RM 5, 15, 25, 35, 45
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J502WA002ZRM 5, 15, 25, 35, 45
Rack mounting type Output receptacle *3 Single-phase 2-wire 200V Single-phase 3-wire 100V/200V A11J502WA002DXRM 5, 15, 25, 35, 45
■ Model
■ Specification
*1: The product of the backup time of a black letter has both the types of rack mounting and Stand-alone type The product of the backup time of a blue letter has Stand-alone type only. *2: Type name of □ stands for the backup time. 0 (5 min, 15 min, 25 min, 35 min, 45 min), 1 (30 min), 2 (60 min), 3 (180 min). Model number will change by the backup time, please specify the backup time required at the time of an order in the □ stands of 0.*3: We can be equipped with up to four UPS unit of 5 kVA. It can also be added after the introduction.
Output capacity 5kVA Size 3U
Output capacity 5kVA Size 3U Output capacity 5kVA Size 4U
7
The output supplied from the inverter startup (Inverter start-up type)
When planning to add one or more UPS units, use a wire size and an input breaker capacity that is applicable to the UPS capacity after one or more UPS units are added.
*1 AC input voltage range changes by load factor.AC input 100 V Load factor 70% or less: -35% to +15% / More than 70%: -15% to +15%, AC input 200 V Load factor 70% or less: -40% to +15% / More than 70%: -20% to +15%A11J502****N(NEMA plug type) is as follows. Load factor 70% or less: -40% to +15% / More than 70%: -10% to +15%
*2 Input frequency range is ± 8% at auto-detect setting. At constant frequency setting, the acceptable range is from 40Hz to 120Hz.
*3 At auto-detect frequency setting, the synchronized frequency range is selectable as ± 1%, ± 3% or ± 5% (factory setting: ± 3%).At constant frequency setting, output frequency is fixed to 50Hz or 60Hz without regard to input frequency.At auto-detect frequency setting, synchronized frequency range is selectable as ± 1%, ± 3% or ± 5% (factory setting: ± 3%).Input frequency range is ±8% at this setting. At constant frequency setting, output frequency is fixed to 50Hz or 60Hz without regard to input frequency. Acceptablerange is from 40Hz to 120Hz at this setting.
*4 A cond i t i ons to sw i t ch to bypass synchronously are as follows.Frequency auto-detect setting is selected.Input frequency is in the synchronized range and input voltage is in the rated voltage range.
*5 Transfer signal:(1) Contact signal: DSUB15 (female) fixing screw M3(2) PC interface: DSUB9 (male) fixing screw #4-40UNCRemote control: Spring clamp terminal block Applicable wires: 26 AWG to 20 AWG
A Japanese operating manual is supplied with the product.
*1: There are rack mounting type and Stand-alone type.*2: We can be equipped with up to four UPS unit of 5 kVA. It can also be added after the introduction.
Type Power Distribution Unit (20 kVA) AC input AC output Model Battery runtime (min)
Single / Terminal block type — Single-phase 2-wire 200V Single-phase 2-wire 200V A11J502A002T4U 10*1
Single / NEMA Plug type — Single-phase 2-wire 200V Single-phase 2-wire 200V A11J502A002N4U 10*1
Stand-alone type — Single-phase 2-wire 100V or Single-phase 2-wire 200V
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J502WA001-4U 10
Single-phase 2-wire 200V Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J502WA002-4U 10
*2 Single-phase 2-wire 200V Single-phase 2-wire 200V A11J502SA002-4U 10
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J502WA002Z-4U 10
Stand-alone type Output Receptacle *2 Single-phase 2-wire 200V Single-phase 3-wire 100V/200V A11J502WA002DX-4U 10
Rack Mounting type — Single-phase 2-wire 100V or Single-phase 2-wire 200V
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J502WA001RM-4U 10
Single-phase 2-wire 200V Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J502WA002RM-4U 10
*2 Single-phase 2-wire 200V Single-phase 2-wire 200V A11J502SA002RM-4U 10
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J502WA002ZRM-4U 10
Rack mounting type Output receptacle *2 Single-phase 2-wire 200V Single-phase 3-wire 100V/200V A11J502WA002DXRM-4U 10
■ Model Output capacity 5kVA Size 4U
A11J502WA002RM A11J502WA002ZRM A11J502WA002DXRM 3U Rack mounting type
Model
A11J502WA002RM-4U A11J502WA002ZRM-4U A11J502WA002DXRM-4U 4U
A11J502WA002 A11J502WA002Z A11J502WA002DX 3U Stand-alone type
A11J502WA002-4U A11J502WA002Z-4U A11J502WA002DX-4U 4U
5 kVA / 4.5 kW N unit setting Rated output capacity(Apparent power / Active power)— N+1 unit setting
True online power supply synchronized with commercial power source Power supply system SystemForced air cooling Cooling systemHigh-frequency PWM Inverter systemVFI-SS-111 IEC Standard (UPS classification)Single-phase 2-wire Number of phase AC
input200 V Rated voltage-40% to +15% Acceptable voltage range *1
50Hz / 60Hz (Selectable Auto-detect or Constant frequency*2 Factory setting: Auto-detect) Rated frequency6 kVA max. Max. capacity0.95 min. (At rated input voltage and input voltage distorsion rate under 1%) Power factorSingle-phase 2-wire or Single-phase 3-wire Single-phase 3-wire Number of phase AC
output100 V (2 W) or 100 V / 200 V (3 W) 100 V / 200 V (3 W) Rated voltage (same as input)Within ± 5% of rated voltage Voltage accuracy50Hz / 60Hz Rated frequency (same as input)Rated frequency Within ± 1, 3, 5% (Factory setting: 3%) On normal operation Frequency range *3
Within ± 0.5% On battery operationSine wave Voltage waveformWithin 3% Max. (Linear load at rated output) Distortion factor of voltage Within ± 5% (10 ⇔ 100% rapid change) Rapid load factor change Transient
voltagevariation
Within ± 5% Power outage / recoveryWithin ± 5% (± 10% rapid change) Rapid input voltage change0.9 lag (acceptable range 0.7 (lag) to 1.0) Load power factor104% and over (Automatic swith to bypass *4) N unit Overcurrent protection— N+1 unit104% (1 min) / 112% (inst.) N unit Inverter Overload
capacity— N+1 unit200% (30 s) / 800% (2 cycles) N unit Bypass— N+1 unitSmall-sized sealed lead-acid battery Type Battery16 unit (12 V / 1 unit) Composition5 Ah / unit 3U Rated capacity9 Ah / unit 4U5 min (Ambient Temp. of 25ºC, Load power factor 0.8 , Default) 3U Battery runtime10 min (Ambient Temp. of 25ºC, Load power factor 0.75 , Default) 4U12 mA max. Input leak current50 dB max. Acoustic noise (At 1m (40 in) from the front of unit)556 W Nominal heat dissipation (at rated output after full recharged)0ºC to 40ºC Operating temperature Environment20% to 90%(Non-condensing) Relative humidityM8 Input Connector I/O
Connector / Wiring Wire, etc. *5
8 mm2 Input wireM8 M8
NEMA L6-30R ×10NEMA 5-15R-dualunit×2
Output Connector
8 mm2 (size AA), 14 mm2 (size C) 8 mm2 Output wire8 mm2 Grounding wire60 A min. 40 A min. 40 A min. Input breaker capacity
8
Specifications
Model Rack mounting type
3U A11J103A002T A11J103SA002RM A11J103WA001RM
4U — A11J103SA002RM-4U A11J103WA001RM-4U
Stand-alone type 3U A11J103A002T A11J103SA002 A11J103WA001
4U — A11J103SA002-4U A11J103WA001-4U
Rated output capacity(Apparent power / Active power)
N unit setting 10 kVA / 9 kWN+1 unit setting 5 kVA / 4.5 kW
System Power supply system True online power supply synchronized with commercial power sourceCooling system Forced air coolingInverter system High-frequency PWM
IEC Standard (UPS classification) VFI-SS-111ACinput
Number of phase Single-phase 2-wireRated voltage 200 V, 208 V, 220 V, 230 V, 240 V (User settable. Factory setting: 200 V) 100 V or 200 V (User settable. Factory setting: 100 V)Acceptable voltage range *1 -40% to +15% -35% to +15% Rated frequency 50Hz / 60Hz (Selectable Auto-detect or Constant frequency*2 Factory setting: Auto-detect)Max. capacity N unit setting 11 kVA 12 kVA max.
N+1 unit setting 6.2 kVA 6.7 kVAPower factor 0.95 min (At rated input voltage and input voltage distorsion rate under 1%)
ACoutput
Number of phase Single-phase 2-wire Single-phase 2-wire or Single-phase 3-wireRated voltage (same as input) 200 V, 208 V, 220 V, 230 V, 240 V (Factory setting: 200 V) 100 V (2 W) or 100 V / 200 V (3 W)Voltage accuracy Within ± 2% of rated voltage Max. ± 5% of rated voltageRated frequency (same as input) 50Hz / 60HzFrequency range *3 On normal operation Rated frequency Within ± 1, 3, 5% (Factory setting: 3%)
On battery operation Within ± 0.5%Voltage waveform Sine waveDistortion factor of voltage Within 3% / 8% (Linear load / Rectifier load at rated output) Within 3% (Linear load / Rectifier load at rated output)Transientvoltagevariation
Rapid load factor change Within ± 5% (0 ⇔ 100% rapid change) Within ± 5% (10 ⇔ 100% rapid change)Power outage / recovery Within ± 5% Rapid input voltage change Within ± 5% (± 10% rapid change)
Load power factor 0.9 lag (acceptable range 0.7 (lag) to 1.0)Overcurrent protection N unit 110% and over (Automatic swith to bypass *4) 104% and over (Automatic swith to bypass *4)
N+1 unit 220% and over (Automatic swith to bypass *4) 208% and over (Automatic swith to bypass *4)Overloadcapacity
Inverter N unit 110% (1 min) / 118% (inst.) 104% (1 min) / 112% (inst.)N+1 unit 220% (1 min) / 236% (inst.) 208% (1 min) / 224% (inst.)
Bypass N unit 200% (30 s) / 800% (2 cycles)N+1 unit 400% (30 s) / 160% (2 cycles)
Battery Type Small-sized sealed lead-acid batteryComposition 32 unit (12 V / 1 unit)Rated capacity 3U 5 Ah / unit
4U — 9 Ah / unitBattery runtime 3U 5 min (Ambient Temp. of 25ºC, Load power factor 0.8 , Default)
4U — 10 min (Ambient Temp. of 25ºC, Load power factor 0.75 , Default)Input leak current 8 mA max. 15 mA max. Acoustic noise (At 1m (40 in) from the front of unit) 50 dB max. 55 dB max.Nominal heat dissipation (at rated output after full recharged) 730 W 1465 WEnvironment Operating temperature 0ºC to 40ºC
Relative humidity 20% to 90% (Non-condensing)I/O Connector / Wiring Wire, etc. *5
Input Connector M6 M8Input wire 22 mm2 22 mm2 (200V), 38 mm2 (100V)Output Connector M6
NEMA L6-30R ×2NEMA L6-20R ×2
M8NEMA L6-30R ×4
M8
Output wire 22 mm2 14 mm2 (1P 3W), 38 mm2 (1P 2W)Grounding wire 14 mm2
Input breaker capacity 80 A min. 80 A (200V), 160 A (100V)
Type Power Distribution Unit (20 kVA) AC input AC output Model*2 Battery runtime (min)
Single / Terminal block type — Single-phase 2-wire 200V Single-phase 2-wire 200V A11J103A0□2T 5, 15, 25, 30, 35, 60, 180*1
Single / NEMA plug type — Single-phase 2-wire 200V Single-phase 2-wire 200V — —Stand-alone type — Single-phase 2-wire 100V or
Single-phase 2-wire 200VSingle-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J103WA0□1 5, 30, 60, 180
Single-phase 2-wire 200V Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J103WA0□2 5, 30, 60, 180
*3 Single-phase 2-wire 200V Single-phase 2-wire 200V A11J103SA0□2 5, 30, 60, 180
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J103WA0□2Z 5, 30, 60, 180
Stand-alone type Output receptacle *3 Single-phase 2-wire 200V Single-phase 3-wire 100V/200V A11J103WA0□2DX 5, 30, 60, 180
Rack mounting type — Single-phase 2-wire 100V or Single-phase 2-wire 200V
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J103WA001RM 5, 15, 25, 35
Single-phase 2-wire 200V Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J103WA002RM 5, 15, 25, 35
*3 Single-phase 2-wire 200V Single-phase 2-wire 200V A11J103SA002RM 5, 15, 25, 35
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J103WA002ZRM 5, 15, 25, 35
Rack mounting type Output receptacle *3 Single-phase 2-wire 200V Single-phase 3-wire 100V/200V A11J103WA002DXRM 5, 15, 25, 35
Output capacity 10kVA Size 3U Output capacity 10kVA Size 4U
■ Model Output capacity 10kVA Size 3U
*1: The product of the backup time of a black letter has both the types of rack mounting and Stand-alone type The product of the backup time of a blue letter has Stand-alone type only. *2: Type name of □ stands for the backup time. 0 (5 min, 15 min, 25 min, 35 min, 45 min), 1 (30 min), 2 (60 min), 3 (180 min). Model number will change by the backup time, please specify the backup time required at the time of an order in the □ stands of 0.*3: We can be equipped with up to four UPS unit of 5 kVA. It can also be added after the introduction.
■ Specification
9
*1: We can be equipped with up to four UPS unit of 5 kVA. It can also be added after the introduction.
Type Power Distribution Unit (20 kVA) AC input AC output Model*2 Battery runtime (min)
Single / Terminal block type — Single-phase 2-wire 200V Single-phase 2-wire 200V — —Single / NEMA plug type — Single-phase 2-wire 200V Single-phase 2-wire 200V — —Stand-alone type — Single-phase 2-wire 100V or
Single-phase 2-wire 200VSingle-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J103WA001-4U 10
Single-phase 2-wire 200V Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J103WA002-4U 10
*3 Single-phase 2-wire 200V Single-phase 2-wire 200V A11J103SA002-4U 10
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J103WA002Z-4U 10
Stand-alone type Output receptacle *3 Single-phase 2-wire 200V Single-phase 3-wire 100V/200V A11J103WA002DX-4U 10
Rack mounting type — Single-phase 2-wire 100V or Single-phase 2-wire 200V
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J103WA001RM-4U 10
Single-phase 2-wire 200V Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J103WA002RM-4U 10
*3 Single-phase 2-wire 200V Single-phase 2-wire 200V A11J103SA002RM-4U 10
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J103WA002ZRM-4U 10
Rack mounting type Output receptacle *3 Single-phase 2-wire 200V Single-phase 3-wire 100V/200V A11J103WA002DXRM-4U 10
■ Model Output capacity 10kVA Size 4U
A11J103WA002RM A11J103WA002ZRM A11J103WA002DXRM 3U Rack mounting type
Model
A11J103WA002RM-4U A11J103WA002ZRM-4U A11J103WA002DXRM-4U 4U
A11J103WA002 A11J103WA002Z A11J103WA002DX 3U Stand-alone type
A11J103WA002-4U A11J103WA002Z-4U A11J103WA002DX-4U 4U
10 kVA / 9 kW N unit setting Rated output capacity(Apparent power / Active power)5 kVA / 4.5 kW N+1 unit setting
True online power supply synchronized with commercial power source Power supply system SystemForced air cooling Cooling systemHigh-frequency PWM Inverter systemVFI-SS-111 IEC Standard (UPS classification)Single-phase 2-wire Number of phase AC
input200 V Rated voltage-40% to +15% Acceptable voltage range *1
50Hz / 60Hz (Selectable Auto-detect or Constant frequency*2 Factory setting: Auto-detect) Rated frequency12 kVA max. N unit setting Max. capacity6.7 kVA N+1 unit setting0.95 min. (At rated input voltage and input voltage distorsion rate under 1%) Power factorSingle-phase 2-wire or Single-phase 3-wire Single-phase 3-wire Number of phase AC
output100 V (2 W) or 100 V / 200 V (3 W) 100 V / 200 V (3 W) Rated voltage (same as input)Within ± 5% of rated voltage Voltage accuracy50Hz / 60Hz Rated frequency (same as input)Rated frequency Within ± 1, 3, 5% (Factory setting: 3%) On normal operation Frequency range *3
Within ± 0.5% On battery operationSine wave Voltage waveformWithin 3% (Linear load / Rectifier load at rated output) Distortion factor of voltage Within ± 5% (10 ⇔ 100% rapid change) Rapid load factor change Transient
voltagevariation
Within ± 5% Power outage / recoveryWithin ± 5% (± 10% rapid change) Rapid input voltage change0.9 lag (acceptable range 0.7 (lag) to 1.0) Load power factor104% and over (Automatic swith to bypass *4) N unit Overcurrent protection208% and over (Automatic swith to bypass *4) N+1 unit104% (1 min) / 112% (inst.) N unit Inverter Overload
capacity208% (1 min) / 224% (inst.) N+1 unit200% (30 s) / 800% (2 cycles) N unit Bypass400% (30 s) / 160% (2 cycles) N+1 unitSmall-sized sealed lead-acid battery Type Battery32 unit (12 V / 1 unit) Composition5 Ah / unit 3U Rated capacity9 Ah / unit 4U5 min. (Ambient Temp. of 25ºC, Load power factor 0.8 , Default) 3U Battery runtime10 min. (Ambient Temp. of 25ºC, Load power factor 0.75 , Default) 4U15 mA max. Input leak current55 dB max. Acoustic noise (At 1m (40 in) from the front of unit)1112 W Nominal heat dissipation (at rated output after full recharged)0ºC to 40ºC Operating temperature Environment20% to 90% (Non-condensing) Relative humidityM8 Input Connector I/O
Connector / Wiring Wire, etc. *5
22 mm2 Input wireM8 M8
NEMA L6-30R ×10NEMA 5-15R-dualunit×2
Output Connector
14 mm2 (1P 3W), 38 mm2 (1P 2W) 14 mm2 Output wire14 mm2 Grounding wire125 A min. 80 A min. Input breaker capacity
The output supplied from the inverter startup (Inverter start-up type)
When planning to add one or more UPS units, use a wire size and an input breaker capacity that is applicable to the UPS capacity after one or more UPS units are added.
*1: AC input voltage range changes by load factor.AC input 100 V Load factor 70% or less: -35% to +15% / More than 70%: -15% to +15%, AC input 200 V Load factor 70% or less: -40% to +15% / More than 70%: -20% to +15%A11J502* ***N(NEMA plug type) is as follows. Load factor 70% or less: -40% to +15% / More than 70%: -10% to +15%
*2: Input frequency range is ± 8% at auto-detect setting. At constant frequency setting, the acceptable range is from 40Hz to 120Hz.
*3: At auto-detect frequency setting, the synchronized frequency range is selectable as ± 1%, ± 3% or ± 5% (factory setting: ± 3%).At constant frequency setting, output frequency is fixed to 50Hz or 60Hz without regard to input frequency.At auto-detect frequency setting, synchronized frequency range is selectable as ± 1%, ± 3% or ± 5% (factory setting: ± 3%).Input frequency range is ±8% at this setting. At constant frequency setting, output frequency is fixed to 50Hz or 60Hz without regard to input frequency. Acceptablerange is from 40Hz to 120Hz at this setting.
*4 : A cond i t ions to swi tch to bypass synchronously are as follows.Frequency auto-detect setting is selected.Input frequency is in the synchronized range and input voltage is in the rated voltage range.
*5: Transfer signal:(1) Contact signal: DSUB15 (female) fixing screw M3(2) PC interface: DSUB9 (male) fixing screw #4-40UNCRemote control: Spring clamp terminal block Applicable wires: 26 AWG to 20 AWG
A Japanese operating manual is supplied with the product.
10
Specifications
Model Rack mounting type 3U A11J153SA002RM A11J153WA002ZRM A11J153WA002DXRM
4U A11J153SA002RM-4U A11J153WA002ZRM-4U A11J153WA002DXRM-4U
Stand-alone type 3U A11J153SA002 A11J153WA002Z A11J153WA002DX
4U A11J153SA002-4U A11J153WA002Z-4U A11J153WA002DX-4U
Rated output capacity(Apparent power / Active power)
N unit setting 15 kVA / 13.5 kWN+1 unit setting 10 kVA / 9 kW
System Power supply system True online power supply synchronized with commercial power sourceCooling system Forced air coolingInverter system High-frequency PWM
IEC Standard (UPS classification) VFI-SS-111ACinput
Number of phase Single-phase 2-wireRated voltage 200 V, 208 V, 220 V, 230 V, 240 V (User settable. Factory setting: 200 V) 200 VAcceptable voltage range *1 -40% to +15%Rated frequency 50Hz / 60Hz (Selectable Auto-detect or Constant frequency*2 Factory setting: Auto-detect)Max. capacity N unit setting 16.5 kVA 18 kVA
N+1 unit setting 11.7 kVA 12.7 kVAPower factor 0.95 min. (At rated input voltage and input voltage distorsion rate under 1%)
ACoutput
Number of phase Single-phase 2-wire Single-phase 2-wire or Single-phase 3-wire
Single-phase 3-wire
Rated voltage (same as input) 200 V, 208 V, 220 V, 230 V, 240 V (Factory setting: 200 V) 100 V (2 W) or 100 V / 200 V (3 W) 100 V / 200 V (3 W)Voltage accuracy Within ± 2% of rated voltage Within ± 5% of rated voltageRated frequency (same as input) 50Hz / 60HzFrequency range *3 On normal operation Rated frequency Within ± 1, 3, 5% (Factory setting: 3%)
On battery operation Within ± 0.5%Voltage waveform Sine waveDistortion factor of voltage Within 3% / 8% (Linear load / Rectifier load at rated output) Within 3% (Linear load / Rectifier load at rated output)Transientvoltagevariation
Rapid load factor change Within ± 5% (0 ⇔ 100% rapid change) Within ± 5% (10 ⇔ 100% rapid change)Power outage / recovery Within ± 5% Rapid input voltage change Within ± 5% (± 10% rapid change)
Load power factor 0.9 lag (acceptable range 0.7 (lag) to 1.0)Overcurrent protection N unit 110% and over (Automatic swith to bypass *4) 104% and over (Automatic swith to bypass *4)
N+1 unit 165% and over (Automatic swith to bypass *4) 156% and over (Automatic swith to bypass *4)Overloadcapacity
Inverter N unit 110% (1 min) / 118% (inst.) 104% (1 min) / 112% (inst.)N+1 unit 165% (1 min) / 177% (inst.) 156% (1 min) / 168% (inst.)
Bypass N unit 200% (30 s) / 800% (2 cycles)N+1 unit 300% (30 s) / 1200% (2 cycles)
Battery Type Small-sized sealed lead-acid batteryComposition 48 unit (12 V / 1 unit)Rated capacity 3U 5 Ah / unit
4U 9 Ah / unitBattery runtime 3U 5 min. (Ambient Temp. of 25ºC, Load power factor 0.8 , Default)
4U 10 min. (Ambient Temp. of 25ºC, Load power factor 0.75 , Default)Input leak current 20 mA max.Acoustic noise (At 1m (40 in) from the front of unit) 50 dB max. Max. 55 dB Nominal heat dissipation (at rated output after full recharged) 1100 W 1669 WEnvironment Operating temperature 0ºC to 40ºC
Relative humidity 20% to 90%(Non-condensing)I/O Connector / Wiring Wire, etc. *5
Input Connector M8Input wire 22 mm2 38 mm2
Output Connector M8NEMA L6-30R ×4
M8 M8 NEMA L6-30R ×10NEMA 5-15R-dualunit×2
Output wire 14 mm2 38 mm2 (1P 3W), 22 mm2 x 2 (1P 2W) 38 mm2
Grounding wire 14 mm2
Input breaker capacity 125 A min.
Type Power Distribution Unit (20 kVA)
AC input AC output 3U 4U
Model*2 Battery runtime (min) Model*2 Battery runtime (min)
Stand-alone type *3 Single-phase 2-wire 200V
Single-phase 2-wire 200V A11J153SA0□2 5, 30, 60, 180 A11J153SA002-4U 10
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J153WA0□2Z 5, 30, 60, 180 A11J153WA002Z-4U 10
Stand-alone type Output Receptacle
*3 Single-phase 2-wire 200V
Single-phase 3-wire 100V/200V A11J153WA0□2DX 5, 30, 60, 180 A11J153WA002DX-4U 10
Rack Mounting Type *3 Single-phase 2-wire 200V
Single-phase 2-wire 200V A11J153SA002RM 5, 15, 25 A11J153SA002RM-4U 10
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J153WA002ZRM 5, 15, 25 A11J153WA002ZRM-4U 10
Rack Mounting Type Output Receptacle
*3 Single-phase 2-wire 200V
Single-phase 3-wire 100V/200V A11J153WA002DXRM 5, 15, 25 A11J153WA002DXRM-4U 10
■ Model Output capacity 15kVA Size 3U, 4U
Output capacity 15kVA Size 3U, 4U ■ Specification
*1: Type name of □ stands for the backup time. 0 (5 min., 15 min., 25 min., 35 min., 45 min.), 1 (30 min.), 2 (60 min.), 3 (180 min.). Model number will change by the backup time, please specify the backup time required at the time of an order in the □ stands of 0.*2: We can be equipped with up to four UPS unit of 5 kVA. It can also be added after the introduction.
The output supplied from the inverter startup (Inverter start-up type)
When planning to add one or more UPS units, use a wire size and an input breaker capacity that is applicable to the UPS capacity after one or more UPS units are added.
*1: AC input voltage range changes by load factor.AC input 100 V Load factor 70% or less: -35% to +15% / More than 70%: -15% to +15%, AC input 200 V Load factor 70% or less: -40% to +15% / More than 70%: -20% to +15%A11J502* ***N(NEMA plug type) is as follows. Load factor 70% or less: -40% to +15% / More than 70%: -10% to +15%
*2: Input frequency range is ± 8% at auto-detect setting. At constant frequency setting, the acceptable range is from 40Hz to 120Hz.
11
Type Power Distribution Unit (20 kVA)
AC input AC output 3U 4U
Model*2 Battery runtime (min) Model*2 Battery runtime (min)
Stand-alone type *3 Single-phase 2-wire 200V
Single-phase 2-wire 200V A11J203SA0□2 5, 30, 60, 180 A11J203SA002-4U 10
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J203WA0□2Z 5, 30, 60, 180 A11J203WA002Z-4U 10
Stand-alone type Output Receptacle
*3 Single-phase 2-wire 200V
Single-phase 3-wire 100V/200V A11J203WA0□2DX 5, 30, 60, 180 A11J203WA002DX-4U 10
Rack Mounting Type *3 Single-phase 2-wire 200V
Single-phase 2-wire 200V A11J203SA002RM 5, 15 A11J203SA002RM-4U 10
Single-phase 2-wire 100V or Single-phase 3-wire 100V/200V
A11J203WA002ZRM 5, 15 A11J203WA002ZRM-4U 10
Rack Mounting Type Output Receptacle
*3 Single-phase 2-wire 200V
Single-phase 3-wire 100V/200V A11J203WA002DXRM 5, 15 A11J203WA002DXRM-4U 10
Model Rack mounting type 3U A11J203SA002RM A11J203WA002ZRM A11J203WA002DXRM
4U A11J203SA002RM-4U A11J203WA002ZRM-4U A11J203WA002DXRM-4U
Stand-alone type 3U A11J203SA002 A11J203WA002Z A11J203WA002DX
4U A11J203SA002-4U A11J203WA002Z-4U A11J203WA002DX-4U
Rated output capacity(Apparent power / Active power)
N unit setting 20 kVA / 18 kWN+1 unit setting 15 kVA / 13.5 kW
System Power supply system True online power supply synchronized with commercial power sourceCooling system Forced air coolingInverter system High-frequency PWM
IEC Standard (UPS classification) VFI-SS-111ACinput
Number of phase Single-phase 2-wireRated voltage 200 V, 208 V, 220 V, 230 V, 240 V (User settable. Factory setting: 200 V) 200 VAcceptable voltage range *1 -40% to +15%Rated frequency 50Hz / 60Hz (Selectable Auto-detect or Constant frequency*2 Factory setting: Auto-detect)Max. capacity N unit setting 22 kVA 24kVA max.
N+1 unit setting 17.2 kVA 18.7 kVAPower factor 0.95 min (At rated input voltage and input voltage distorsion rate under 1%)
ACoutput
Number of phase Single-phase 2-wire Single-phase 2-wire or Single-phase 3-wire
Single-phase 3-wire
Rated voltage (same as input) 200 V, 208 V, 220 V, 230 V, 240 V (Factory setting: 200 V) 100 V (2 W) or 100 V / 200 V (3 W) 100 V / 200 V (3 W)Voltage accuracy Within ± 2% of rated voltage ± 5% of rated voltage max.Rated frequency (same as input) 50Hz / 60HzFrequency range *3 On normal operation Rated frequency Within ± 1, 3, 5% (Factory setting: 3%)
On battery operation Within ± 0.5%Voltage waveform Sine waveDistortion factor of voltage Within 3% / 8% (Linear load / Rectifier load at rated output) Within 3% (Linear load / Rectifier load at rated output)Transientvoltagevariation
Rapid load factor change Within ± 5% (0 ⇔ 100% rapid change) Within ± 5% (10 ⇔ 100% rapid change)Power outage / recovery Within ± 5% Rapid input voltage change Within ± 5% (± 10% rapid change)
Load power factor 0.9 lag (acceptable range 0.7 (lag) to 1.0)Overcurrent protection N unit 110% and over (Automatic swith to bypass *4) 104% and over (Automatic swith to bypass *4)
N+1 unit 147% and over (Automatic swith to bypass *4) 138% and over (Automatic swith to bypass *4)Overloadcapacity
Inverter N unit 110% (1 min) / 118% (inst.) 104% (1 min) / 112% (inst.)N+1 unit 147% (1 min) / 157% (inst.) 138% (1 min) / 149% (inst.)
Bypass N unit 200% (30 s) / 800% (2 cycles)N+1 unit 300% (30 s) / 1200% (2 cycles)
Battery Type Small-sized sealed lead-acid batteryComposition 64 unit (12 V / 1 unit)Rated capacity 3U 5 Ah / unit
4U 9 Ah / unitBattery runtime 3U 5 min (Ambient Temp. of 25 C゚, Load power factor 0.8 , Default)
4U 10 min (Ambient Temp. of 25 C゚, Load power factor 0.75 , Default)Input leak current 20 mA max. Acoustic noise (At 1m (40 in) from the front of unit) 50 dB max. 55 dB max. Nominal heat dissipation (at rated output after full recharged) 1500 W 2225 WEnvironment Operating temperature 0 C゚ to 40 C゚
Relative humidity 20 to 90%(Non-condensing)I/O Connector / Wiring Wire, etc. *5
Input Connector M8Input wire 60 mm2
Output Connector M8NEMA L6-30R ×4
M8 M8 NEMA L6-30R ×10NEMA 5-15R-dualunit×2
Output wire 60 mm2 60 mm2 (1P 3W), 38 mm2 x 2 (1P 2W) 60 mm2
Grounding wire 14 mm2
Input breaker capacity 160 A max.
■ Model Output capacity 20kVA Size 3U, 4U
Output capacity 20kVA Size 3U, 4U ■ Specification
*1: Type name of □ stands for the backup time. 0 (5 min., 15 min., 25 min., 35 min., 45 min.), 1 (30 min.), 2 (60 min.), 3 (180 min.). Model number will change by the backup time, please specify the backup time required at the time of an order in the □ stands of 0.*2: We can be equipped with up to four UPS unit of 5 kVA. It can also be added after the introduction.
*3: At auto-detect frequency setting, the synchronized frequency range is selectable as ± 1%, ± 3% or ± 5% (factory setting: ± 3%).At constant frequency setting, output frequency is fixed to 50Hz or 60Hz without regard to input frequency.At auto-detect frequency setting, synchronized frequency range is selectable as ± 1%, ± 3% or ± 5% (factory setting: ± 3%).Input frequency range is ±8% at this setting. At constant frequency setting, output frequency is fixed to 50Hz or 60Hz without regard to input frequency. Acceptablerange is from 40Hz to 120Hz at this setting.
*4: A conditions to switch to bypass synchronously are as follows.Frequency auto-detect setting is selected.・ Input frequency is in the synchronized range and input voltage is in the rated voltage range.
*5: Transfer signal: (1) Contact signal: DSUB15 (female) fixing screw M3 (2) PC interface: DSUB9 (male) fixing screw #4-40UNC Remote control: Spring clamp terminal block Applicable wires: 26 AWG to 20 AWG
A Japanese operating manual is supplied with the product.
12
Power factor & Run-time chart
0 20 40 60 80 100 120
Power factor [%]
Run-time [min.]
100
80
60
40
20
10
5 min.
10 min.
■ Output capacity 5kVA Stand-alone typeModel*1 A11J502A0□2T
A11J502A0□2NA11J502SA0□2 A11J502WA0□1 A11J502WA0□2 A11J502WA0□2Z A11J502WA0□2DX
Dimensions Fig.1 Fig.3 Fig.5 Fig.5 Fig.7 Fig.7
Width 435 435 435 435 435 435
Depth*2 700+30 700+80 700+80 700+80 700+80 700+80
Height 130 408 541 541 718 718
Mass*3With a battery pack 61 kg 101 kg 211 kg 181 kg 266 kg 271 kg
Without a battery pack 26 kg 66 kg 176 kg 146 kg 231 kg 236 kg
Model*1 A11J502A002T4U A11J502A002N4U
A11J502SA002-4U A11J502WA001-4U A11J502WA002-4U A11J502WA002Z-4U A11J502WA002DX-4U
Dimensions Fig.2 Fig.4 Fig.6 Fig.6 Fig.8 Fig.8
Width 435 435 435 435 435 435
Depth*2 700+30 700+80 700+80 700+80 700+80 700+80
Height 175 453 586 586 763 763
Mass*3With a battery pack 80 kg 120 kg 230 kg 200 kg 285 kg 290 kg
Without a battery pack — — — — — —
(Note) Ambient Temp. of 25°C, Default, Load power factor / Backup time 5 min = 0.8, Backup time 10 min = 0.75
Fig.8
763
I130
480 731
700
130
190
443
435
700
700435
408
ALA RM
541
MAINMC C B
O U TPU T
INPU T
718
MC CBMA IN
INPU T
O U TPU T
AL A RM
Fig.1 Horizontal / Rack mounting Vertical
Fig.3 Fig.5
Fig.7
435
Fig.2 Horizontal / Rack mounting Vertical
480 731
175
435 700
175
234
443
435
700O
UT
PU
T
INP
UT
ALA
RM
MC
CB
MA
IN
Fig.4
700435
453
Fig.6
OUTPUT
INPUT
MAINMCCB
ALARM
586
700435700435
700435700435
Dimensions : mm
13
■ Output capacity 20kVA Stand-alone typeModel*1 A11J203SA0□2 A11J203WA0□2Z A11J203WA0□2DX A11J203SA002-4U A11J203WA002Z-4U A11J203WA002DX-4U
Dimensions Fig.20 Fig.22 Fig.22 Fig.21 Fig.23 Fig.23
Width 435 435 435 435 435 435
Depth*2 700+80 700+80 700+80 700+80 700+80 700+80
Height 803 1113 1113 981 1291 1291
Mass*3With a battery pack 284 kg 449 kg 454 kg 360 kg 525 kg 530 kg
Without a battery pack 144 kg 309 kg 314 kg — — —
*1: Type name of □ stands for the backup time. 0 (5 min, 15 min, 25 min, 35 min, 45 min), 1 (30 min), 2 (60 min), 3 (180 min).*2: UPS unit + cable cover / terminal block / Protruding portion *3: With a battery pack (Battery runtime: 5 min, 15 min, 25 min, 35 min, 45 min), Without a battery pack (Battery runtime: 30, 60, 180 min) The indicated mass is for the UPS only. As total mass of the device differs by battery runtime, see the page 15.
■ Output capacity 10kVA Stand-alone typeModel*1 A11J103A0□2T A11J103SA0□2 A11J103WA0□1 A11J103WA0□2 A11J103WA0□2Z
Dimensions Fig.9 Fig.10 Fig.12 Fig.12 Fig.14
Width 435 435 435 435 435
Depth*2 700+90 700+80 700+80 700+80 700+80
Height 262 540 673 673 850
Mass*3With a battery pack 125kg 162kg 322kg 272kg 327kg
Without a battery pack 55kg 92kg 252kg 202kg 257kg
Model*1 A11J103WA0□2DX A11J103SA002-4U A11J103WA001-4U A11J103WA002-4U A11J103WA002Z-4U A11J103WA002DX-4U
Dimensions Fig.14 Fig.11 Fig.13 Fig.13 Fig.15 Fig.15
Width 435 435 435 435 435 435
Depth*2 700+80 700+80 700+80 700+80 700+80 700+80
Height 850 629 762 762 939 939
Mass*3With a battery pack 332 kg 200 kg 360 kg 310 kg 365 kg 370kg
Without a battery pack 262 kg — — — — —
■ Output capacity 15kVA Stand-alone typeModel*1 A11J153SA0□2 A11J153WA0□2Z A11J153WA0□2DX A11J153SA002-4U A11J153WA002Z-4U A11J153WA002DX-4U
Dimensions Fig.16 Fig.18 Fig.18 Fig.17 Fig.19 Fig.19
Width 435 435 435 435 435 435
Depth*2 700+80 700+80 700+80 700+80 700+80 700+80
Height 671 981 981 805 1115 1115
Mass*3With a battery pack 223 kg 388 kg 393 kg 280 kg 445 kg 450 kg
Without a battery pack 118 kg 283 kg 288 kg — — —
Paint color : Black (Munsell N1.5)
Fig.11
435
629
700700
262
IIII
322
443
435
262
480
435 II
435
540
II
700
673
43585
0IIII
Fig.9 Horizontal / Rack mounting Vertical Fig.10
Fig.12 Fig.14Fig.13
435
762
700
Fig.15435
939
700
700
700435
700
700
I
671
435
Fig.16 Fig.17
700435
805
700
981
II
II
435
II
Fig.18 Fig.19 435 700
1115
I
435
803
700
435 700
1113
III
Fig.20 Fig.22Fig.21
435 700
981
Fig.23
1291
435 700
14
Dimensions : mm
■ Output capacity 5kVA Rack Mounting TypeModel A11J502SA002RM A11J502WA001RM A11J502WA002RM A11J502WA002ZRM A11J502WA002DXRM
Battery runtime 5 min 5 min 5 min 5 min 5 min
Dimensions Fig.24+Fig.26 Fig.24+Fig.27 Fig.24+Fig.27 Fig.24+Fig.28 Fig.24+Fig.28
Width 435 435 435 435 435
Depth*1 700+80 700+80 700+80 700+80 700+80
Height 306 439 439 616 616
Mass 94 kg 204 kg 174 kg 259 kg 264 kg
Model A11J502SA002RM-4U A11J502WA001RM-4U A11J502WA002RM-4U A11J502WA002ZRM-4U A11J502WA002DXRM-4U
Battery runtime 10 min 10 min 10 min 10 min 10 min
Dimensions Fig.25+Fig.26 Fig.25+Fig.27 Fig.25+Fig.27 Fig.25+Fig.28 Fig.25+Fig.28
Width 435 435 435 435 435
Depth*1 700+80 700+80 700+80 700+80 700+80
Height 351 484 484 661 661
Mass 113 kg 223 kg 193 kg 278 kg 283 kg
■ Output capacity 10kVA Rack Mounting TypeModel A11J103SA002RM A11J103WA001RM A11J103WA002RM A11J103WA002ZRM A11J103WA002DXRM
Battery runtime 5 min 5 min 5 min 5 min 5 min
Dimensions Fig.24×2unit*2+Fig.26 Fig.24×2unit*2+Fig.27 Fig.24×2unit*2+Fig.27 Fig.24×2unit*2+Fig.28 Fig.24×2unit*2+Fig.28
Width 435 435 435 435 435
Depth*1 700+80 700+80 700+80 700+80 700+80
Height 436 569 569 746 746
Mass 155 kg 315 kg 265 kg 320 kg 325 kg
Model A11J103SA002RM-4U A11J103WA001RM-4U A11J103WA002RM-4U A11J103WA002ZRM-4U A11J103WA002DXRM-4U
Battery runtime 10 min 10 min 10 min 10 min 10 min
Dimensions Fig.25×2unit*2+Fig.26 Fig.25×2unit*2+Fig.27 Fig.25×2unit*2+Fig.27 Fig.25×2unit*2+Fig.28 Fig.25×2unit*2+Fig.28
Width 435 435 435 435 435
Depth*1 700+80 700+80 700+80 700+80 700+80
Height 525 659 659 836 836
Mass 193 kg 353 kg 303 kg 358 kg 363 kg
■ Output capacity 15kVA Rack Mounting TypeModel A11J153SA002RM A11J153WA002ZRM A11J153WA002DXRM A11J153SA002RM-4U A11J153WA002ZRM-4U A11J153WA002DXRM-4U
Battery runtime 5 min 5 min 5 min 10 min 10 min 10 min
Dimensions Fig.24×3unit*2+Fig.26 Fig.24×3unit*2+Fig.28 Fig.24×3unit*2+Fig.28 Fig.25×3unit*2+Fig.26 Fig.25×3unit*2+Fig.28 Fig.25×3unit*2+Fig.28
Width 435 435 435 435 435 435
Depth*1 700+80 700+80 700+80 700+80 700+80 700+80
Height 566 876 876 700 1011 1011
Mass 216 kg 381 kg 386 kg 273 kg 438 kg 443 kg
■ Output capacity 20kVA Rack Mounting TypeModel A11J203SA002RM A11J203WA002ZRM A11J203WA002DXRM A11J203SA002RM-4U A11J203WA002ZRM-4U A11J203WA002DXRM-4U
Battery runtime 5 min 5 min 5 min 10 min 10 min 10 min
Dimensions Fig.24×4unit*2+Fig.26 Fig.24×4unit*2+Fig.28 Fig.24×4unit*2+Fig.28 Fig.25×4unit*2+Fig.26 Fig.25×4unit*2+Fig.28 Fig.25×4unit*2+Fig.28
Width 435 435 435 435 435 435
Depth*1 700+80 700+80 700+80 700+80 700+80 700+80
Height 696 1006 1006 874 1186 1186
Mass 277 kg 442 kg 447 kg 353 kg 518 kg 523 kg
*1: UPS unit + cable cover*2: The second and the following UPS units are not equipped with an LCD display panel.
Paint color: Black (Munsell N1.5)
Fig.24
Fig.26
Power distribution unit
731
700
480
435
175
Fig.25
731
700435
175
480
Fig.27
700435
309
Fig.28
700435
486
731
700435
480
130 I
15
Option
■ Rack Support Rail Dimensions : mm
Used for mounting the UPS onto a 19 inch rack.
■ Transformer Box Dimensions : mm
This is a rack-mounting transformer unit that can be mounted in a 19-inch rack and that can convert the voltage from 200 V to 100 V.
A transformer, a breaker, and a receptacle are integrated into the unit to save space so that the 2U size can be achieved.
* The battery cabinet, and transformer box are not UL/CE certified.
■ Battery BoxFig. Dimensions : mm Mass Capacity of
battery(Ah ・ cell)
Optional battery composition
Width Depth*1 Height Output capacity 5 kVA Output capacity 10 kVA Output capacity 15 kVA Output capacity 20 kVA
15 min 25 min 35 min 45 min 15 min 25 min 35 min 45 min 15 min 25 min 35 min 45 min 15 min 25 min 35 min 45 min
29 435 700+80 130 49 kg 480 1 unit — 1 unit — — — 2 unit — 1 unit — — — — — — —
29 435 700+80 130 84 kg 960 — 1 unit 1 unit 2 unit 1 unit 2 unit 2 unit — 1 unit 3 unit — — 2 unit — — —
*1: UPS unit + cable cover
■ Battery CabinetFig. Dimensions : mm (inch) Mass Capacity of
battery(Ah ・ cell)
Optional battery composition
Width Depth*1 Height Output capacity 5 kVA Output capacity 10 kVA Output capacity 15 kVA Output capacity 20 kVA
30 min 60 min 180 min 30 min 60 min 180 min 30 min 60 min 180 min 30 min 60 min 180 min
30 440 700+12 544 215 kg 2688 1 unit — — — — — 1 unit — — — — —
31 440 700+12 988 415 kg 5376 — — — 1 unit — — 1 unit — — 2 unit — —
32 440 870+12 544 320 kg 4224 — 1 unit — — — — — 1 unit — — — —
33 440 870+12 988 620 kg 8448 — — 1 unit — 1 unit 2 unit — 1 unit 3 unit — 2 unit 4 unit
*1: UPS unit + cable cover
Fig.29
700435
130
Fig.30 Fig.32Fig.31 Fig.33
544
700440 440
544
870
988
700440
988
440 870
Model No.: RM027 Model No.: RM028 Model No.: RMA11JWB00 Model No.: RM030
654 to 798
(for Fig.27, 28)
48
135
Rack mounting dimension654 to 798
180
48
Rack mounting dimension
480
175
688 to 798
Rack mounting dimension
88
48 555 to 913Rack mounting dimension
A set of left and right rails (for Fig.24, 29). The figure shows the left rail.
A set of left and right rails (for Fig.25, 26). The figure shows the left rail.
A set of left and right rails (for Transformer Box). The figure shows the left rail.
Model No.: TRA11J502A00TRM Model No.: TRA11J502A00NRM
I/O terminal block: M6, output receptacle: 5-15R-dual-unit x 4 circuitsMass: Approx. 42 kg
Input plug: L6-30P, output terminal block: M6, output receptacle: 5-15R-dual-unit x 4 circuitsMass: Approx. 42 kg
435
480
86
607
577 435
480
86
577
607
Item Model Remarks
LAN interface card PRLANIF003-US Provides continuous monitoring and reporting of power conditions. Power problems can also be reported to the system manager via e-mail.
PRLANIF005-US (Environmental monitoring function) This model includes the functions of the PRLANIF003 and adds the capability to monitor UPS ambient temperature and humidity utilizing temperature and humidity sensors. Temperature sensor : PRLANSN001, Humidity sensor : PRLANSN002 (sold separately)
SANUPS SOFTWARE PMS40J00E (Windows version without cable)PMS41J00E (Multi-OS version * without cable)
This software automatically shuts down the system and stops the UPS when a failure occurs in the commercial power supply.
* For Windows, Unix and Linux
Please ask us about UL / CE certified.
16
Specifications
700
I
671
435Fig.37
I130
480
700
130
190
443
435
700700435
408
Fig.34 Horizontal / Rack mounting Vertical Fig.35
435
700
II
435
540
II
Fig.36
I
435
803
700Fig.38
Model A11J502A002TU A11J502SA002U A11J103SA002U A11J153SA002U A11J203SA002U Model
Rated output capacity(Apparent power/Active power)
N unit setting 5 kVA / 4.5 kW 10 kVA / 9 kW 15kVA / 13.5kW 20kVA / 17kW N unit setting Rated output capacity(Apparent power/Active power)N+1 unit setting — 5 kVA / 4.5 kW 10kVA / 9kW 15kVA / 13.5kW N+1 unit setting
System Power supply system True online power supply synchronized with commercial power source True online power supply synchronized with commercial power source Power supply system SystemCooling system Forced air cooling Forced air cooling Cooling systemInverter system High-frequency PWM High-frequency PWM Inverter system
IEC Standard (UPS classification) VFI-SS-111 VFI-SS-111 IEC Standard (UPS classification)ACinput
Number of phase Single-phase 2-wire Single-phase 2-wire Number of phase ACinputRated voltage 200 V, 208 V, 220 V, 230 V, 240 V (User settable. Factory setting: 200 V) 200 V, 208 V, 220 V, 230 V, 240 V (User settable. Factory setting: 200 V) Rated voltage
Acceptable voltage range *1 -40% to +15% -40% to +15% Acceptable voltage range *1
Rated frequency 50Hz / 60Hz (Selectable Auto-detect or Constant frequency*2 Factory setting: Auto-detect) 50Hz / 60Hz (Selectable Auto-detect or Constant frequency*2 Factory setting: Auto-detect) Rated frequencyMax. capacity N unit setting 5.5 kVA 11 kVA 16.5 kVA 19.8 kVA N unit setting Max. capacity
N+1 unit setting — 6.2 kVA 11.7 kVA 17.2 kVA N+1 unit settingPower factor Min. 0.95 (At rated input voltage and input voltage distorsion rate under 1%) Min. 0.95 (At rated input voltage and input voltage distorsion rate under 1%) Power factor
ACoutput
Number of phase Single-phase 2-wire Single-phase 2-wire Number of phase ACoutputRated voltage (same as input) 200 V, 208 V, 220 V, 230 V, 240 V (Factory setting: 200 V) 200 V, 208 V, 220 V, 230 V, 240 V (Factory setting: 200 V) Rated voltage (same as input)
Voltage accuracy Within ± 2% of rated voltage Within ± 2% of rated voltage Voltage accuracyRated frequency (same as input) 50Hz / 60Hz 50Hz / 60Hz Rated frequency (same as input)Frequency range *2 On normal operation Rated frequency Within ± 1, 3, 5% (Factory setting: 3%) Rated frequency Within ± 1, 3, 5% (Factory setting: 3%) On normal operation Frequency range *2
On battery operation Within ± 0.5% Within ± 0.5% On battery operationVoltage waveform Sine wave Sine wave Voltage waveformDistortion factor of voltage Within 3% / 8% (Linear load / Rectifier load at rated output) Within 3% / 8% (Linear load / Rectifier load at rated output) Distortion factor of voltage Transientvoltagevariation
Rapid load factor change Within ± 5% (0 ⇔ 100% rapid change) Within ± 5% (0 ⇔ 100% rapid change) Rapid load factor change Transientvoltagevariation
Power outage / recovery Within ± 5% Within ± 5% Power outage / recoveryRapid input voltage change Within ± 5% (± 10% rapid change) Within ± 5% (± 10% rapid change) Rapid input voltage change
Load power factor N unit 0.9 lag (acceptable range 0.7 (lag) to 1.0) 0.9 lag (acceptable range 0.7 (lag) to 1.0) 0.85 lag N unit Load power factorN+1 unit 0.9 lag (acceptable range 0.7 (lag) to 1.0) 0.9 lag (acceptable range 0.7 (lag) to 1.0) N+1 unit
Overcurrent protection N unit 110% and over (Automatic swith to bypass *4) 110% and over (Automatic swith to bypass *4) N unit Overcurrent protectionN+1 unit — Within 220% 165% and over 147% and over N+1 unit
Overloadcapacity
Inverter N unit 110% (1 min.) / 118% (inst.) 110% (1 min.) / 118% (inst.) N unit Inverter OverloadcapacityN+1 unit — 220% / 236% 165% / 177% 147% / 157% N+1 unit
Bypass N unit 200% (30 sec.) / 800% (2 cycles) 200% (30 sec.) / 800% (2 cycles) N unit BypassN+1 unit — 400% / 1600% 300% / 1200% 267% / 1067% N+1 unit
Battery*3 Type Small-sized sealed lead-acid battery Small-sized sealed lead-acid battery Type Battery*3
Composition 16unit (12 V / 1unit) 32unit (12 V / 1unit) 48unit (12 V / 1unit) 64unit (12 V / 1unit) CompositionRated capacity 5 Ah / unit 5 Ah / unit Rated capacityBattery runtime 5 min. (Ambient Temp. of 25 C゚, Load power factor 0.8 , Default) 5 min. (Ambient Temp. of 25 C゚, Load power factor 0.8 , Default) Battery runtime
Input leak current Max. 4 mA Max. 12 mA Max. 15mA Max. 20 mA Max. 25 mA Input leak currentAcoustic noise (At 1m from the front of unit) Max. 45 dB Max. 50 dB Max. 50 dB Acoustic noise (At 1m from the front of unit)Nominal heat dissipation (at rated output after full recharged) 339 W 350 W 730 W 1100 W 1500 W Nominal heat dissipation (at rated output after full recharged) Environment Operating temperature 0 C゚ to 40 C゚ 0 C゚ to 40 C゚ Operating temperature Environment
Relative humidity 20% to 90% (Non-condensing) 20% to 90% (Non-condensing) Relative humidityI/O Connector / Wiring Wire, etc. *5
Input Connector Field wireless terminalblock: Applicable wire 20 to 4 AWG
Field wireless terminalblock: Applicable wire 6 to 1/0 AWG
Field wireless terminalblock: Applicable wire 6 to 1/0 AWG
Input Connector I/O Connector / Wiring Wire, etc. *5
Input wire 8 mm2 (8 AWG) 14 mm2 (6 AWG) 22 mm2 (4 AWG) 50mm2 (1 AWG) 60mm2 (1/0 AWG) Input wireOutput Connector 8 mm2 (8 AWG) 14 mm2 (6 AWG) 22 mm2 (4 AWG) 50mm2 (1 AWG) 60mm2 (1/0 AWG) Output ConnectorOutput wire 5.5 mm2 (10 AWG) 14 mm2 (6 AWG) 14 mm2 (6 AWG) 22mm2 (4 AWG) 38mm2 (2 AWG) Output wireInput breaker capacity 35 A (UL489 certified unit) 70 A (UL489 certified unit) 100A (UL489 certified unit) 125A (UL489 certified unit) Input breaker capacity
Safety standard UL1778-4th/C22.2 No.107.3-05-2nd, CE: IEC62040-1:2008 UL1778-4th/C22.2 No.107.3-05-2nd, CE: IEC62040-1:2008 Safety standardEmission standard EN62040-2 C3 : 2006, EN55022:2006 Class-A, FCC Part15 Sub partB Class-A EN62040-2 C3 : 2006, EN55022:2006 Class-A, FCC Part15 Sub partB Class-A Emission standardImmunity EN62040-2:2006, EN55024:1998/A1:2001/A2:2003 EN62040-2:2006, EN55024:1998/A1:2001/A2:2003 Immunity
■ Specifications Table UL/CE certified Output capacity 5kVA, 10kVA, 15kVA, 20kVA Size 3U
Model A11J502A002TU A11J502SA002U A11J103SA002U A11J153SA002U A11J203SA002U
Dimensions Fig.34 Fig.35 Fig.36 Fig.37 Fig.38
Width 435 435 435 435 435
Depth*1 700+115 700+160 700+160 700+160 700+160
Height 130 408 540 671 803
Mass 61 kg 91 kg 152 kg 213 kg 274 kg
*1: UPS unit + cable cover
Paint color: Black (Munsell N1.5)
Dimensions : mm (inch)
17
When planning to add one or more UPS units, use a wire size and an input breaker capacity that is applicable to the UPS capacity after one or more UPS units are added.
*1 AC input voltage range changes by load factor.Load factor 70% or less: -40% to +15% / More than 70%: -20% to +15%Note that when recovering from power outages at a load factor of 70% or less, the abnormal voltage detection value (-40%) will be -20%.
*2 At au to -detec t f requency se t t ing , synchronized frequency range is selectable as ± 1%, ± 3% or ± 5% (factory setting: ± 3%). Acceptable frequency range is ±8% at this setting.
At constant frequency setting, output frequency is fixed to 50Hz or 60Hz without regard to input frequency. Acceptable range is from 40Hz to 120Hz at this setting.
Note that when recovering from outside the acceptab le range , accep tab le frequency range will be±8% in either setting.
The inverter will not run if input frequency is not within the set value (±1%, ±3%, ±5%) of the synchronized frequency range.
*3 Battery runtime can be extended through the addition of optional battery boxes. Contact us for details.
*4 A cond i t i ons to sw i t ch to bypass synchronously are as follows.Frequency auto-detect setting is selected.・ Input frequency is in the synchronized range and input voltage is in the rated voltage range.
*5 Transfer signal:(1) Contact signal: DSUB15 (female) fixing screw M3(2) PC interface: DSUB9 (male) fixing screw #4-40UNCRemote control: Spring clamp terminal block Applicable wires: 26 AWG to 20 AWG
Japanese and English operating manuals are supplied with the UL/CE certified model.
Model A11J502A002TU A11J502SA002U A11J103SA002U A11J153SA002U A11J203SA002U Model
Rated output capacity(Apparent power/Active power)
N unit setting 5 kVA / 4.5 kW 10 kVA / 9 kW 15kVA / 13.5kW 20kVA / 17kW N unit setting Rated output capacity(Apparent power/Active power)N+1 unit setting — 5 kVA / 4.5 kW 10kVA / 9kW 15kVA / 13.5kW N+1 unit setting
System Power supply system True online power supply synchronized with commercial power source True online power supply synchronized with commercial power source Power supply system SystemCooling system Forced air cooling Forced air cooling Cooling systemInverter system High-frequency PWM High-frequency PWM Inverter system
IEC Standard (UPS classification) VFI-SS-111 VFI-SS-111 IEC Standard (UPS classification)ACinput
Number of phase Single-phase 2-wire Single-phase 2-wire Number of phase ACinputRated voltage 200 V, 208 V, 220 V, 230 V, 240 V (User settable. Factory setting: 200 V) 200 V, 208 V, 220 V, 230 V, 240 V (User settable. Factory setting: 200 V) Rated voltage
Acceptable voltage range *1 -40% to +15% -40% to +15% Acceptable voltage range *1
Rated frequency 50Hz / 60Hz (Selectable Auto-detect or Constant frequency*2 Factory setting: Auto-detect) 50Hz / 60Hz (Selectable Auto-detect or Constant frequency*2 Factory setting: Auto-detect) Rated frequencyMax. capacity N unit setting 5.5 kVA 11 kVA 16.5 kVA 19.8 kVA N unit setting Max. capacity
N+1 unit setting — 6.2 kVA 11.7 kVA 17.2 kVA N+1 unit settingPower factor Min. 0.95 (At rated input voltage and input voltage distorsion rate under 1%) Min. 0.95 (At rated input voltage and input voltage distorsion rate under 1%) Power factor
ACoutput
Number of phase Single-phase 2-wire Single-phase 2-wire Number of phase ACoutputRated voltage (same as input) 200 V, 208 V, 220 V, 230 V, 240 V (Factory setting: 200 V) 200 V, 208 V, 220 V, 230 V, 240 V (Factory setting: 200 V) Rated voltage (same as input)
Voltage accuracy Within ± 2% of rated voltage Within ± 2% of rated voltage Voltage accuracyRated frequency (same as input) 50Hz / 60Hz 50Hz / 60Hz Rated frequency (same as input)Frequency range *2 On normal operation Rated frequency Within ± 1, 3, 5% (Factory setting: 3%) Rated frequency Within ± 1, 3, 5% (Factory setting: 3%) On normal operation Frequency range *2
On battery operation Within ± 0.5% Within ± 0.5% On battery operationVoltage waveform Sine wave Sine wave Voltage waveformDistortion factor of voltage Within 3% / 8% (Linear load / Rectifier load at rated output) Within 3% / 8% (Linear load / Rectifier load at rated output) Distortion factor of voltage Transientvoltagevariation
Rapid load factor change Within ± 5% (0 ⇔ 100% rapid change) Within ± 5% (0 ⇔ 100% rapid change) Rapid load factor change Transientvoltagevariation
Power outage / recovery Within ± 5% Within ± 5% Power outage / recoveryRapid input voltage change Within ± 5% (± 10% rapid change) Within ± 5% (± 10% rapid change) Rapid input voltage change
Load power factor N unit 0.9 lag (acceptable range 0.7 (lag) to 1.0) 0.9 lag (acceptable range 0.7 (lag) to 1.0) 0.85 lag N unit Load power factorN+1 unit 0.9 lag (acceptable range 0.7 (lag) to 1.0) 0.9 lag (acceptable range 0.7 (lag) to 1.0) N+1 unit
Overcurrent protection N unit 110% and over (Automatic swith to bypass *4) 110% and over (Automatic swith to bypass *4) N unit Overcurrent protectionN+1 unit — Within 220% 165% and over 147% and over N+1 unit
Overloadcapacity
Inverter N unit 110% (1 min.) / 118% (inst.) 110% (1 min.) / 118% (inst.) N unit Inverter OverloadcapacityN+1 unit — 220% / 236% 165% / 177% 147% / 157% N+1 unit
Bypass N unit 200% (30 sec.) / 800% (2 cycles) 200% (30 sec.) / 800% (2 cycles) N unit BypassN+1 unit — 400% / 1600% 300% / 1200% 267% / 1067% N+1 unit
Battery*3 Type Small-sized sealed lead-acid battery Small-sized sealed lead-acid battery Type Battery*3
Composition 16unit (12 V / 1unit) 32unit (12 V / 1unit) 48unit (12 V / 1unit) 64unit (12 V / 1unit) CompositionRated capacity 5 Ah / unit 5 Ah / unit Rated capacityBattery runtime 5 min. (Ambient Temp. of 25 C゚, Load power factor 0.8 , Default) 5 min. (Ambient Temp. of 25 C゚, Load power factor 0.8 , Default) Battery runtime
Input leak current Max. 4 mA Max. 12 mA Max. 15mA Max. 20 mA Max. 25 mA Input leak currentAcoustic noise (At 1m from the front of unit) Max. 45 dB Max. 50 dB Max. 50 dB Acoustic noise (At 1m from the front of unit)Nominal heat dissipation (at rated output after full recharged) 339 W 350 W 730 W 1100 W 1500 W Nominal heat dissipation (at rated output after full recharged) Environment Operating temperature 0 C゚ to 40 C゚ 0 C゚ to 40 C゚ Operating temperature Environment
Relative humidity 20% to 90% (Non-condensing) 20% to 90% (Non-condensing) Relative humidityI/O Connector / Wiring Wire, etc. *5
Input Connector Field wireless terminalblock: Applicable wire 20 to 4 AWG
Field wireless terminalblock: Applicable wire 6 to 1/0 AWG
Field wireless terminalblock: Applicable wire 6 to 1/0 AWG
Input Connector I/O Connector / Wiring Wire, etc. *5
Input wire 8 mm2 (8 AWG) 14 mm2 (6 AWG) 22 mm2 (4 AWG) 50mm2 (1 AWG) 60mm2 (1/0 AWG) Input wireOutput Connector 8 mm2 (8 AWG) 14 mm2 (6 AWG) 22 mm2 (4 AWG) 50mm2 (1 AWG) 60mm2 (1/0 AWG) Output ConnectorOutput wire 5.5 mm2 (10 AWG) 14 mm2 (6 AWG) 14 mm2 (6 AWG) 22mm2 (4 AWG) 38mm2 (2 AWG) Output wireInput breaker capacity 35 A (UL489 certified unit) 70 A (UL489 certified unit) 100A (UL489 certified unit) 125A (UL489 certified unit) Input breaker capacity
Safety standard UL1778-4th/C22.2 No.107.3-05-2nd, CE: IEC62040-1:2008 UL1778-4th/C22.2 No.107.3-05-2nd, CE: IEC62040-1:2008 Safety standardEmission standard EN62040-2 C3 : 2006, EN55022:2006 Class-A, FCC Part15 Sub partB Class-A EN62040-2 C3 : 2006, EN55022:2006 Class-A, FCC Part15 Sub partB Class-A Emission standardImmunity EN62040-2:2006, EN55024:1998/A1:2001/A2:2003 EN62040-2:2006, EN55024:1998/A1:2001/A2:2003 Immunity
18
MEMO
19
The names of companies and/or their products specified in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies.Specifications are subject to change without notice.
Eco Products
Sanyo Denki’s ECO PRODUCTS are designed with the concept of lessening impact on the environment in the process from product development to waste. The product units and packaging materials are designed for reduced environmental impact. We have established our own assessment criteria on the environmental impacts applicable to all processes, ranging from design to manufacture. Those products that satisfy the criteria are accredited as ECO PRODUCTS.
※For any inquiry or consultation, please contact our sales representative.
Notes when investigating use of this product in your applicationsBefore starting installation, assembling and use, read the “Operation Manual” carefully and use the product correctly in your applications.
When you are going to use this product in the following application, the special considerations are required for operation, running, maintenance and control. Be sure to consult with our company as a part of your investigations.
(a) Medical equipment and other equipment that are related directly to human life.
(b) Train or elevator that can give injury to human body.
(c) Socially and publicly important computer systems.
(d) And other equipment that are related to safety of human life and that can affect severe effects on maintenance of public functions.
For the applications that undergo vibration such as vehicles, ships and transportation facilities, please consult with our company.
Never modify this product or give additional processing to this product.
For the installation andmaintenance work, please consult with our company or with specialized company.
This product may be regulated under export and trade control regulations of each country. During export of each product, compliance to the export regulations of each country is highly recommended.
Our company shall not be responsible for damages (including but not limited to equipment downtime, power sales revenue, business interruptions, increased power purchases) resulting from use or non-use of this product and services.
http://www.sanyodenki.com
TEL: +81 3 5927 1020
TEL: +49 6196 76113 0
TEL: +82 2 773 5623
TEL: +86 21 6235 1107
TEL: +1 310 783 5400
TEL: +33 1 48 63 26 61
TEL: +886 2 2511 3938
TEL: +852 2312 6250
TEL: +65 6223 1071
468 Amapola Avenue Torrance, CA 90501, U.S.A.
3-33-1, Minami-Otsuka, Toshima-ku, Tokyo, 170-8451, Japan
P.A. Paris Nord Ⅱ, 48 Allée des Erables-VILLEPINTE, BP.57286, F-95958 ROISSY CDG Cedex, France
Frankfurter Strasse 92, 65760 Eschborn, Germany
988 Toa Payoh North, #04-05/06/07/08, Singapore 319002
Room 2106-2109, Bldg A, Far East International Plaza, No.319, Xianxia Road, Shanghai, 200051, China
TEL: +86 10 6522 2160Room1222, Tower B, Beijing COFCO Plaza, No.8 Jianguomennei Dajie, Dong Cheng District, Beijing 100005 China
N-711, 7F, Chia Hsin 2nd Bldg., No.96, Sec.2, Zhongshan N. Rd., Taipei 10449, Taiwan (R.O.C.)
Room 2305, 23/F, South Tower, Concordia Plaza, 1 Science Museum Road, TST East, Kowloon, Hong Kong
9F, Sunhwa B/D 89, Seosomun-ro, Jung-gu, Seoul, 100-731, Korea
TEL: +86 755 3337 38682F 02-11, Shenzhen International Chamber of Commerce Tower, No.168 Fuhua 3 Road, Futian District, Shenzhen, 518048 China
TEL: +66 2261 8670388 Exchange Tower, 25th Floor, Unit 2501-1, Sukhumvit Road, Klongtoey, Klongtoey, Bangkok 10110 Thailand
Beijing Branch
TEL: +86 22 2320 1186Room AB 16th Floor TEDA Building, No. 256 Jie Fang Nan Road, Hexi District, Tianjin 300042 ChinaTianjin Representative Office
TEL: +86 28 8661 6901Room2105B, Block A, Times Plaza, 2 Zongfu Road, Jinjiang District, Chengdu, 610016 ChinaChengdu Representative Office
TEL: + 62 21 252 3202Summitmas II 4th Floor, Jl. Jend. Sudirman Kav.61-62, Jakarta 12190, IndonesiaIndonesia Representative Office
TEL: +82 51 796 5151 8F, CJ Korea Express Bldg., 119, Daegyo-ro, Jung-gu, Busan, 600-016, KoreaBusan Branch
CATALOG No.P0953B005 ‘14.11
ONLINE UPS
A11J