omnialog data acquisition systems · 2020. 11. 2. · omnialog data acquisition systems 2 omn_das...
TRANSCRIPT
-
CRDOMN_DASCRDOMN_DAS
_ OMNIALOGDATA ACQUISITION SYSTEMS
READOUT UNITSAND DATALOGGERS
-
OMNIALOG DATA ACQUISITION SYSTEMS 2www.sisgeo.com
OMN_DAS
OM
NIA
_DA
S_E
N_0
0_03
/201
3
OMNIALOGDATA ACQUISITION SYSTEMSOMNIAlog data aquisition system is designed to be versatile and flexible. By adding modular components the system can be configured to handle the simplest or the most complex projects.A single logger, housed in a cabinet with multiplexer expansion boards and a communication interface, can manage a large number of sensors. OMNIAlog system is easily adapted for many application, such as tunnels or dams by using external multiplexer boxes. Such distributed system can be connected in a daisy chain or in a star configuration. Recorded data can be downloaded via USB memory stick or pushed to remote servers by ftp and telecommunications. Alerts can be sent by email and graphs and reports can be generated on web pages to access anywhere.
APPLICATIONS
• Tunnelling
• Dam surveillance
• Structural monitoring
• Mining exploration
• Deep excavation
• Landslide safety implementation
• Retaining walls
• Geotechnical investigation campaigns
FEATURES
• Installation allowed in unattended areas or hard environment conditions
• Rated for wide temperature range
• Compatible with all major geotechnical sensors, both analogues and digitals
• 2 GB internal memory
• Stand alone or part of a network
• Built - in vibrating wire interface
OM
NIA
_DA
S_E
N_0
4_06
/201
9
www.sisgeo.com
-
OMNIALOG DATA ACQUISITION SYSTEMS 3www.sisgeo.com
OMN_DAS
OM
NIA
_DA
S_E
N_0
5_11
/202
0
DAMS AND HPPThese projects usually require many different types of sensors. Instrument cables can be connected at MUX boxes and read with portable readouts in the first phase. In the second phase, the MUX boxes can be connected to OMNIAlog datalogger in the control room by special cables.
TUNNELSAND MINES For tunnelling applications, data acquisition systems must be easily reconfigured. OMNIAlog system offers a wide variety of communication interfaces that are easy to change. In addition, MUX boxes can be used as temporary manual reading stations and later connected to a logger.
MAIN REFERENCES FOR DAMS AND HYDRO POWER PROJECTS:Cahora Bassa HPP, Mozambique - Hidroelectrica de Cahora BassaNeckartal Dam and Bulk Water, Namibia - Salini Namibia PTY LTDAzad Dam, Iran - SadafzarHozian Dam, Iran - Lorestan Water AuthoritiesUMA OYA Multitipurpose Project, Sri Lanka - Ministry of Irrigation and Water ResourcesMetolong Dam, Lesotho - Sinohydro Corporation LTDKufranja Dam, Jordan - Società Italiana per Condotte d’Acqua SpAMavrovo Dam, Tikves Dam, Globocica Dam, Spilje Dam, Macedonia - ELEMNam Gnouang Dam, Laos - CMC Ravenna - Vientiane - Lao PDRCerro del Águila Hydroelectric power plant, Perù - ASTALDI S.p.A. Sucursal del PerúQanouna Dam, Saudi Arabia - Envirotec International Co. LTD.
MAIN REFERENCES FOR TUNNELS, MINES AND UNDERGROUND WORKS:L.A. Subway Purple Line Extension, California USA - Analysis and Solutions ConsultantsMikhailovskiy mine, Russia - GPIKO LTDGrand Paris Metro, France - Various CustomersAitik mine, Sweden - Boliden Mineral ABLima Metro Line 1, Perù - Applus Norcontrol PERU’MRT Orange Line E1, Thailand - Sisgeo Asia Pacific Co., LtdRiyadh Metro, Saudi Arabia - Environmental Mechanism Trading EstablishmentDoha Metro, Qatar - Soletanche BachyStratoni Mine, Greece - Hellas Gold SAWarsaw Metro Project, Poland - AGP Metro PolskaBrenner Tunnel, Italy / Austria - GD Test Srl
-
OMNIALOG DATA ACQUISITION SYSTEMS 4www.sisgeo.com
OMN_DAS
OM
NIA
_DA
S_E
N_0
5_11
/202
0
HISTORICAL ANDCIVIL STRUCTURESOMNIAlog components can be installed at any location in the structure to collect readings from the installed instruments. If a local LAN network already exists, OMNIAlog can be connected to it, creating a centralized on-line system automatically. No other interfaces are needed.
LANDSLIDES AND MOBILITY INFRASTRUCTURESIn remote locations, monitoring is simplfied by using a GPRS modem or a 4G router. OMNIAlog can be installed at different locations in a landslide area or along a railway or motorway, collecting readings from sensors and transmitting them to a central location for real-time processing and alerting.
MAIN REFERENCES FOR HISTORICAL BUILDINGS AND CIVIL STRUCTURES:Semey Sports Arena, Kazakhstan - BAYS LLPMorandi Bridge monitoring, Genova, Italy - Field SrlBosphorous Third Bridge, Turkey - Sisgeo ZeminAstana Ice Palace, Kazakhstan - Bays LLCSochi Central Olympic Stadium, Russia - LLC Geocommerce Barcelona Airport, Spain - Applus NorcontrolSaint Helena new Airport, St. Helena Island - Basil Read LtdAstana National Library, Kazakhstan - Monitoring System Group LLPPatras Port, Greece - Aktor SAAlgeri Mosque, Algeria - Trevi SpAMoscow City Plot 11 Skyscraper, Russia - LLC Geocommerce
MAIN REFERENCES FOR LANDSLIDES AND MOBILITY INFRASTRUCTURES:Highway West Georgia Landslide monitoring, Georgia - Hydrodiagnostics LTDAmsterdam Schiphol Airport, Netherlands - Zensor NVWien Sanierung Parlament, Austria - Meixner Vermessung ZT GMBHMaratea Landslide, Italy - SMA SpAIonia Motorway, Greece - Dragados SA and Ferrovial Agroman SAVarious Landslide monitoring in Sochi, Russia - AGT SystemsSibiu Landslide, Romania - Astaldi SpAYapi Merkezi Asia Transition Box, Turkey - Sisgeo ZeminMiglionico Landslide, Italy - SMA SpAOued Tlelat-Tlemcen railway, Algerie - Società Italiana Condotte d’Acqua SpaStuttgard Landslide, Germany - Geomesstec
-
OMNIALOG DATA ACQUISITION SYSTEMS 5www.sisgeo.com
OMN_DAS
OM
NIA
_DA
S_E
N_0
5_11
/202
0
DATALOGGER CABINET0OMNCAB2000CAB2 is a compact cabinet ready to house OMNIAlog modules. It includes a IP65 polycarbonate enclosure with mounting brackets, a 12V 7Ah battery, USB memory stick and a LAN cable for local connection to the PC. The system can be powered by AC mains or by a solar power kit.
OMNIAlog module (Not included)
Backup battery
Connector for power supply
Cable gland for instrument cables
Included Optional
Communication interface area
Reserved area for one of the following devices:- 1 or 2 multiplexer boards for analogue instruments (0OMN24MUX00)- 1 digital instruments power supply and wiring board (0OMX24V100W)- 1 wiring board for 4 chains of external multiplexers (0OMX4MUXEXT)
Datalogger (1)
Enclosure
Backup battery
Number of MUX boards supported
Installation
Instrument cable input
On board communication ports
Display and keyboard
OMNIAlog module GT-816 or GT2400 or GT-100D
Lockable polycarbonate IP65 box, 500x400x200 mm (HxLxW). Customized enclosures are available
12V 7Ah. Not installed if the system is powered by solar panel kit
Up to 2 internal mux or up to16 external MUX. 16 total MUX. (Not allowed with OMNIAlog GT-100D)
Enclosure has 4 brakets for wall mounting. Compatible with 0AX0SH15X80 support frame
M63 cable gland. Customized cable glands are available on request
LAN port (10/100 Mbps, RJ45), USB port (2.0, pen drive only), RS232 port (GPRS modem only)
Backlight LCD 128x64 dpi with membrane keyboard for simple local management without PC
(1) refer to OMNIAlog datasheet for further information and specifications
400 mm
500
mm
1
1
2
2
3
3
4
5
66
5
TECHNICAL SPECIFICATIONS
4
-
OMNIALOG DATA ACQUISITION SYSTEMS 6www.sisgeo.com
OMN_DAS
OM
NIA
_DA
S_E
N_0
5_11
/202
0
DATALOGGER CABINET0OMNCAB3000CAB3 is a cabinet ready to house OMNIAlog modules with room for internal expansion. It includes a high quality and durable IP65 stainless steel enclosure which is installed on a wall or support frame, a rack for up to 3 multiplexer boards, a 12V 7Ah battery, a USB memory stick and a LAN cable for local connection to the PC. The system can be powered by AC mains or by a solar power kit.
OMNIAlog module (Not included)
Backup battery
Cable gland
Communication interface area
Rack for up to 3 multiplexer boards (0OMN24MUX00)
Reserved area for one of the following devices:- 1 digital instruments kit (0OMX24V100W)- 1 4 - chain mux box wiring board (0OMX4MUXEXT)
600 mm
400
mm
Datalogger (1)
Enclosure
Backup battery
Number of MUX boards supported
Installation
On board communication ports
Display and keyboard
OMNIAlog module GT-816 or GT2400 or GT-100D
Lockable stainless steel IP65 box, 400x600x250 mm (HxLxW). Customized enclosures are available
12V 7Ah. Not inserted if supplied with solar panel kit
Up to 3 internal MUX (24 channels each), up to 13 external MUX (24 channels each). 16 total MUX.(Not allowed with OMNIAlog GT-100D)
Enclosure has 4 brakets for wall mounting. Compatible with 0AX0SH15X80 support frame
LAN port (10/100 Mbps, RJ45), USB port (2.0, pen drive only), RS-232 port (GPRS modem only)
Backlight LCD 128x64 dpi with membrane keyboard for simple local management without PC
(1) refer to OMNIAlog datasheet for further information and specifications
1
1
2
2
3
3
44
5
66
Included Optional5
TECHNICAL SPECIFICATIONS
-
OMNIALOG DATA ACQUISITION SYSTEMS 7www.sisgeo.com
OMN_DAS
OM
NIA
_DA
S_E
N_0
5_11
/202
0
DATALOGGER CABINET0OMNCAB8000CAB8 is a cabinet ready to house OMNIAlog modules. It supports both internal and external multiplexer expansion boards. The CAB8 includes a high quality and durable IP65 stainless steel enclosure with wall mounting brackets, a rack for up to 8 multiplexer boards, a 12V 7Ah battery, a USB memory stick and a LAN cable for local connection to the PC. The system is powered by AC mains or by a solar panel kit.
OMNIAlog module (Not included)
Backup battery
Cable glands, ID Ø 42 mm
Communication interface area
Rack for up to 8 multiplexer boards (0OMN24MUX00)
1 digital instruments kit (0OMX24V100W)
4-chain mux box wiring board area (0OMX4MUXEXT)
TECHNICAL SPECIFICATIONS
600 mm
600
mm
Datalogger (1)
Enclosure
Backup battery
Number of MUX boards supported
Installation
On board communication ports
Display and keyboard
OMNIAlog module GT-816 or GT2400 or GT-100D
Lockable stainless steel IP65 box, 600x600x250 mm (HxLxW). Customized enclosures available.
12V 7Ah. Not inserted if supplied with solar panel kit
Up to 8 internal MUX (24 channels each), up to 8 external MUX (24 channels each). 16 total MUX.(Not allowed with OMNIAlog GT-100D)
Enclosure has 4 brakets for wall mounting. Compatible with 0AX0SH15X80 support frame
LAN port (10/100 Mbps, RJ45), USB port (2.0, pen drive only), RS-232 port (GPRS modem only)
Backlight LCD 128x64 dpi with membrane keyboard for minimal management without PC
(1) refer to OMNIAlog datasheet for further information and specifications
1
2
3
4
45
5
6
7
7
1
2
6
3
Included Optional
-
OMNIALOG DATA ACQUISITION SYSTEMS 8www.sisgeo.com
OMN_DAS
OM
NIA
_DA
S_E
N_0
5_11
/202
0
APPLICATION IN COMPLEXDISTRIBUTED ARCHITECTURE
PHASE 1
PHASE 2
Max 1200m
OMNIALOG CABINET
EXTERNAL MUX BOX 0OMN48MUXB0
INSTRUMENTS ANDMULTICORE CABLES
EXTERNAL MUX BOX 0OMN24MUXB0
EXTERNAL MUX BOX 0OMN24MUXB0
JUMPER CABLE 0ECAV10MUX0
MUX CABLE 0WE610MUXZH
MUX CABLE 0WE610MUXZH
EXTERNAL MUX BOX 0OMN24MUXB0
INTERNAL MUX 0OMN24MUX00
MUX WIRING BOARD0OMX4MUXEXT
Instruments are installed and wired to multiplexer boxes that serve as a temporary reading stations. The New Leonardo portable readout, connected by a special cable, can operate the multiplexer and collect readings by clicking a button.
Multiplexer boxes are connected to OMNIAlog cabinet system which then manages all the instruments wired to the MUX boxes. OMNIAlog cabinet system can also manage internal multiplexer boards and chains of digital sensors.
NEW LEONARDO0CDL400N000
-
OMNIALOG DATA ACQUISITION SYSTEMS 9www.sisgeo.com
OMN_DAS
OM
NIA
_DA
S_E
N_0
5_11
/202
0
COMMUNICATION INTERFACES
POWER SUPPLY UNITS
SUPPORT FRAME0AX0SH15X80
Galvanized steel mounting frame compatible with all OMNIAlog cabinets.
MAINS POWER SUPPLY0AXBCO22058
AC/DC charger, IP67Oper. temp. -25 to +60°CVin 90-264 Vac, 47-63 HzVout 13.2 Vdc, 2.1 A.
SOLAR PANEL PACKAGE0AX00W000AH
Solar panel power supply for pole mounting. It includes solar panel, battery with regulator, and support brackets.
POLE FOR SOLAR PANEL 0AX0PALO280
Floor -mounted 3m pole with base plate for solar panel kit. Also available for mounting on support frame mod. 0AX0SH0PALO.
VPN 4G ROUTER0OMXRO4G000
4G-VPN advanced router for fast connection, required when internet service provider does not support static IP addresses and inbound/outbound data traffic. Automatic fall-back to 3G network. For pushing data via ftp or email. Allowed allarms: email and ftp. Three models are available to fit all the 4G bands worldwide: bands list are available in SISGEO website - F.A.Q.#108.
EXPANSION DEVICES
DC/DC 12/24V converter and wiring board for expanding up to:- 250 digital sensors,100 W- 60 digital sensors, 60 Wboth distributed in 4 chains maximum.
DIGITAL SENSOR KITS0OMX24V100W-0OMX24V030W
24 channel relay multiplexer with surge arrestors for each channel.
24 CH MUX BOARD0OMN24MUX00
24 channel relays multiplexer, housed in IP65 polycarbonate box (300x300x180mm) including surge arrestors for each channel.
24 CH MUX BOX 0OMN24MUXB0
48 channel relays multiplexer, housed in IP65 polycarbonate box (400x300x180mm) including surge arrestors for each channel.
48 CH MUX BOX0OMN48MUXB0
OMNIAlog cabinet
pole for support frame
support frame
solar panel
battery package
EXAMPLE OF OMNIALOG CABINET MOUNTED ON SUPPORT FRAME AND POWERED WITH SOLAR PANEL KIT
FIBER OPTIC INTERFACE 0OMXFOMMSWTSwitch ethernet with multimode optical fiber ports for in/out (max 4 jumps). Available only upon request.
3G MODEM0OMXMODEM3G3G dual-band modem, antenna and 10m cable. For pushing data via ftp or email. Allowed allarms: sms, email and ftp. 2G network compatible.
-
OMNIALOG DATA ACQUISITION SYSTEMS 10www.sisgeo.com
OMN_DAS
OM
NIA
_DA
S_E
N_0
0_03
/201
3 OMNIALOG SOFTWARE
OMNIAlog software is built into the OMNIAlog. With a simple web browser, user can configure the logger, download data, set alarm thresholds and view graphs. The OMNIAlog user interface is written in HTML and is compatible with all browsers. No other software is needed. Once logged into the OMNIAlog module, users see a banner with icons showing logger status, alarms, availability of firmware updates, power supply, and local date/time. A menu on the left side, lets the user navigate to all the logger functions. OMNIAlog software is available in English, Italian and French languages.
Acquisition configurationtime intervals
Local channel configuration
OMNIAlog graphs
www.sisgeo.com
-
OMNIALOG DATA ACQUISITION SYSTEMS 11www.sisgeo.com
OMN_DAS
OM
NIA
_DA
S_E
N_0
5_11
/202
0
All the information in this document is the property of Sisgeo S.r.l. and should not be used without permission from Sisgeo S.r.l. We reserve the right to change our products without prior notice. The datasheet is issued in English and other languages. In order to avoid discrepancies and disagreement on the interpretation of the meanings, Sisgeo Srl declares that English Language prevails.
SISGEO S.R.L.Via F. Serpero 4/F120060 Masate (MI) Italy Phone +39 02 95764130 Fax +39 02 [email protected]
TECHNICAL ASSISTANCESISGEO offers customers e-mail and phone assistance to ensure proper use of instruments and readout and to maximize performance of the system.
For more information, please refer to the FAQ pages on our website or email us: [email protected]
OMNIALOG COMMUNICATION FEATURES
INTERFACE
OMNIAlog without communication interface
OMNIAlog with
0OMXMODEM3G 3G modem
OMNIAlog with 0OMXRO4G000 4G-VPN router
INTERFACE
OMNIAlog with 3G modem
OMNIAlog with INTERNET ROUTER 4G-VPN
LOCAL DATA DOWNLOAD
LAN OR USB FLASHDRIVE
LAN OR USB FLASHDRIVE
LAN OR USB FLASHDRIVE
NORTH AMERICA / CANADA
COMPATIBILITY
NO
YES, choose for 0OMXRO4G0NA
model
ALARMSDATA PUSHING REMOTE
CONNECTIONEMAIL
NO
YES
YES
NO
NO(only in emergency case)
YES
EMAIL
NO
YES
YES
SMS
NO
YES
NO
FTP
NO
YES
YES
FTP
NO
YES
YES
NOTE: all of these features may not work if the ISP selected by the user blocks these types of services. It is always customer responsibility to make sure that the SIM used enables these services.
mailto:assistance%40sisgeo.com?subject=