CONVENTIONAL SOLUTIONS

Page 2: OLUTIONS ONVENTIONAL - DallasBuildingSecuritySolutions · † Meets NFPA standards 13, 15 and 16 † Three Form-C programmable relays for Alarm, ... Tel: 34-93-497-3960 Fax: 34-93-465-8635

SFP-2402/04 FIRE ALARM CONTROL PANELS SFP-5UD/10UD FIRE ALARM CONTROL PANELSWITH COMMUNICATORS

RP-2001/02 DELUGE/PRE-ACTION AND RELEASING CONTROL PANELS

Initiating Device Circuits (IDCs)2 IDCs on the SFP-2402; 4 IDCs on the SFP-2404

Notification Appliance Circuits (NACs)1 NAC on the SFP-2402; 2 NACs on the SFP-2404

NBG-12 Series Manual Pull Stations

2151 Photo Detectori3 SeriesSmoke Detector

P2R Horn/Strobes24 VDC non-resettable power (SFP-2404 only)

Alarm and Trouble Contacts411/411UD

Notification Appliance Circuits (NACs)4 NACs on the SFP-5UD and SFP-10UD

NBG-12 Series Manual Pull Stations

2151 Photo Detector i3 SeriesSmoke Detector

Initiating Device Circuits (IDCs)5 IDCs on the SFP-5UD; 10 IDCs on the SFP-10UD

P2R Horn/StrobesUp to 8 ANN-BUS devices

N-ANN-LED N-ANN-RLY N-ANN-S/PG N-ANN-I/O N-ANN-80ANN-BUS

Initiating Device Circuits (IDCs)6 IDCs on the RP-2001 and RP-2002

Notification Appliance Circuits (NACs)4 NACs/Releasing Circuits on the RP-2001 and RP-2002 NBG-12 Series Manual Pull Stations

2151 Photo Detectori3 SeriesSmoke Detector

P2R Horn/Strobes

Up to 8 ANN-BUS devices

N-ANN-LEDN-ANN-RLYN-ANN-S/PGN-ANN-I/ON-ANN-80

ANN-BUS

SFP-2402The SFP-2402 is a conventional fire alarmcontrol panel with two alarm initiating zones.• Two Class B Initiating Device Circuits (IDCs)• One Class B Notification Appliance

(NAC) with programmable strobesynchronization

• 3.0 amps total system power• Form-C Alarm and Trouble relays• Optional Voice Evacuation with direct connect

to FireVoice 25/50• Resettable auxillary 24 VDC power• UL 864 Ninth Edition listed

SFP-2404The SFP-2404 is a conventional fire alarmcontrol panel with four alarm initiating zones.• Four Class B Initiating Device Circuits (IDCs),

Class A option available • Two Class B Notification Appliance Circuits

(NACs) with programmable strobesynchronization; Class A option available

• 3.0 amps total system power, expandableto 6.0 amps

• Form-C Alarm, Trouble and Supervisory relays• Optional Voice Evacuation with direct connect

to FireVoice 25/50• Optional local energy box or reverse

polarity XMTR• Optional LED remote annunciator• Optional zone relay module• Resettable and non-resettable auxillary

24 VDC power• UL 864 Ninth Edition listed

SFP-5UDThe SFP-5UD is a 5-zone fire alarm controlpanel with a built-in digital alarm communicatortransmitter (DACT) and remote siteupload/download capability.• Five Class B Initiating Device Circuits (IDCs),

Class A optional with N-CAC-5X convertermodule

• Four Class B NACs rated at 2.5 amps, Class Aoptional with N-CAC-5X converter module

• 3.0 amps total system power • Up to eight ANN-BUS devices (such as LCD

annunciators)• Serial or parallel printer interface• 80-character LCD display• Optional Voice Evacuation available

with direct connect to FireVoice 25/50• Optional IP Communicator• UL 864 Ninth Edition listed

SFP-10UDThe SFP-10UD is a 10-zone fire alarm controlpanel with a built-in digital alarm communicatortransmitter (DACT) and remote siteupload/download capability.• Ten Class B Initiating Device Circuits (IDCs),

Class A optional with N-CAC-5X convertermodule (2 required)

• Four Class B NACs rated at 3.0 amps,Class A optional with N-CAC-5X converter module (2 required)

• 7.0 amps total system power • Up to eight ANN-BUS devices (such as LCD

annunciators)• Serial or parallel printer interface• 80-character LCD display• Optional Voice Evacuation available

with direct connect to FireVoice 25/50• Optional IP Communicator• UL 864 Ninth Edition listed

RP-2001 The RP-2001 is a six-zone fire alarm panel for single or dual hazard deluge andpreaction applications. The RP-2001 is easily programmed with just a few menuselections using field selectable “application templates.” The RP-2001 offers firedetection, signaling and protection for commercial, industrial and institutionalbuildings requiring water-based releasing.• Six Class B Initiating Device Circuits (IDCs); Class A optional with N-CAC-5X

converter module (2 required)• Four Class B Output Circuits programmable as Notification Appliance Circuits

(NACs), or releasing circuits; rated at 3.0 amps; Class A optional with N-CAC-5Xconverter module (2 required)

• Programmable waterflow discharge timer and two soak timers • Cross-zone (double-interlock) capability• Meets NFPA standards 13, 15 and 16 • Three Form-C programmable relays for Alarm, Trouble and Supervisory• Up to eight ANN-BUS devices (such as LCD annunciators)• 80 character LCD display • 7.0 amps total system power• UL 864 Ninth Edition listed

RP-2002The RP-2002 is a six-zone fire alarm control panel for single or dual hazard agentreleasing applications. The RP-2002 offers fire detection, signaling and protectionfor facilities requiring agent-based releasing. Like the RP-2001, this panel can be pro-grammed with an “application template” while remaining completely field-customizable.• Six Class B Initiating Device Circuits (IDCs); Class A optional with N-CAC-5X converter

module (2 required)• Four Class B Output Circuits rated at 3.0 amps; programmable as Notification

Appliance Circuits (NACs), or releasing circuits; Class A optional with N-CAC-5Xconverter module (2 required)

• Adjustable pre-discharge, discharge, and waterflow delay• Meets NFPA standards 12, 12A, 12B, and 2001• Disable/Enable control per input zone and output zone• Cross-zone (double-interlock) capability• Three Form-C programmable relays for Alarm, Trouble and Supervisory• Up to eight ANN-BUS devices (such as LCD annunciators)• 80 character LCD display • 7.0 amps total system power• UL 864 Ninth Edition listed

Page 3: OLUTIONS ONVENTIONAL - DallasBuildingSecuritySolutions · † Meets NFPA standards 13, 15 and 16 † Three Form-C programmable relays for Alarm, ... Tel: 34-93-497-3960 Fax: 34-93-465-8635

M-B-CONV 5K 3/09

NOTIFIER WORLD HEADQUARTERS12 Clintonville RoadNorthford, CT 06472United States of AmericaTel: 203-484-7161Fax: 203-484-7118www.notifier.com

THE AMERICAS

NOTIFIER CanadaToronto, CanadaTel: 905-856-8733Fax: 905-856-9687

Additional Locations in Canada:Montreal, QuebecVancouver, British Columbia

NOTIFIER Central America& Andean Region

Tel: 507-392-72-66Fax: 1-203-484-5397

NOTIFIER MéxicoTel: 52-33-318-83-376Fax: 52-33-318-83-376

NOTIFIER BrazilTel: 55-11-3475-1933Fax: 55-11-3475-1893

NOTIFIER South America Tel: 54-11-432-45-900Fax: 1-203-484-5442

ASIA

NOTIFIER ChinaTel: 86-21-2894-2000Fax: 86-21-5895-9047

Additional Locations in China:BeijingCheng DuChong QingGuang ZhouNan JingQing DaoSheng YangShen ZhenTian JingWu HanXi’an

SOUTH EAST ASIA

NOTIFIER IndiaTel: 91-22-67650721Fax: 91- 22-67650730

NOTIFIER Hong KongTel: 852-2730-9090Fax: 852-2736-6590

NOTIFIER KoreaTel: 82- 2-2025-0308Fax: 82- 2-2025-0329

NOTIFIER SingaporeTel: 65-6271-5503Fax: 65-6271-9961

NOTIFIER TaiwanTel: 886-2-2245-7248Fax: 886-2-2245-0927

NOTIFIER VietnamTel: 84-8-39106012Fax: 84-8-39106015

NOTIFIER MalaysiaTel: 603-55159395Fax: 603-55104259

AUSTRALIA

NOTIFIER Inertia Fire SystemsSydney, AustraliaTel: 61-2-9899-4155Fax: 61-2-9899-4156

Additional Locations:Brisbane, QueenslandMelbourne, VictoriaPerth, Western AustraliaAuckland, New Zealand

MIDDLE EAST & AFRICA

NOTIFIER Dubai, UAETel: 971 4 807 3200Fax: 971 4 881 6202

EUROPE

NOTIFIER United KingdomTel: 44-14-44-230-300Fax: 44-14-44-230-888

NOTIFIER BeneluxTel: 32-42-470-300Fax: 32-42-470-220

NOTIFIER GermanyTel: 49 2102 700 690Fax: 49 2102 700 69 44

NOTIFIER ItalyTel: 390-2-518-971Fax: 390-2-518-9730

NOTIFIER SpainTel: 34-93-497-3960Fax: 34-93-465-8635

NOTIFIER NorwayTel: 47 32 24 48 00Fax: 47 32 24 48 01

For over 50 years, NOTIFIER has been a leader in the fire alarm industry. Today, we arethe largest manufacturer of engineered fire alarm systems with over 400 distributorsworldwide, and regional support operations on every continent helping to ensure weprovide the flexibility and options your business needs.

NOTIFIER - Leaders in Life. Safety. Technology.