oiml r 137 1
TRANSCRIPT
![Page 1: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/1.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 1/48
![Page 2: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/2.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 2/48
OIML R 137-1: 2006 (E)
Contents
QQQ
![Page 3: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/3.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 3/48
OIML R 137-1: 2006 (E)
Foreword
International Recommendations (OIML R),
International Documents (OIML D),
International Guides (OIML G),
International Basic Publications (OIML B),
Vocabularies (OIML V) Expert Reports (OIML E)
Gas meters
![Page 4: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/4.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 4/48
OIML R 137-1: 2006 (E)
Gas meters
Part 1: Requirements
1 Scope
Measuring systems for gaseous fuel
2 Terminology
2.1 GAS METER AND ITS CONSTITUENTS
![Page 5: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/5.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 5/48
OIML R 137-1: 2006 (E)
Note: A printing device, which provides an indication at the end of the measurement, is not an indicating device.
Note 1: An ancillary device is not necessarily subject to metrological control.
Note 2: An ancillary device may be integrated in the gas meter.
QQQQ
![Page 6: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/6.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 6/48
OIML R 137-1: 2006 (E)
2.2 METROLOGICAL CHARACTERISTICS
V m E
Y
Y
Y
e
ref
ref i
Y
Y Y e
n
i
i
n
i
ii
eQQ
WME
eQ
![Page 7: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/7.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 7/48
OIML R 137-1: 2006 (E)
e
Note: In practice this is the difference between the error of the meter observed during or after a test, and the error of the meter prior to this test, performed under reference conditions.
Note: Operating and base conditions relate to the volume of gas to be measured or indicated only and should not
be confused with “rated operating conditions” and “reference conditions” (VIM 5.05 and 5.07) which refer
to influence quantities.
Note: For a digital device, this is the change in the indication when the least significant digit changes by one step.
For an analogue device, this is half the difference between subsequent scale marks.
2.3 OPERATING CONDITIONS
Q
![Page 8: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/8.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 8/48
OIML R 137-1: 2006 (E)
Q
Q
Q
t
t t
p
p p
p
pt
2.4 TEST CONDITIONS
Note: An influence quantity is a disturbance if for that influence quantity the rated operating conditions are not
specified.
![Page 9: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/9.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 9/48
OIML R 137-1: 2006 (E)
2.5 ELECTRONIC EQUIPMENT
Note: For the purposes of this Recommendation auxiliary equipment, as far as it is subject to metrological control,
is considered part of the gas meter, unless the auxiliary equipment is approved and verified separately.
3 Constructional requirements
3.1 CONSTRUCTION
![Page 10: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/10.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 10/48
OIML R 137-1: 2006 (E)
Note: National or regional requirements may contain provisions to guarantee access to the
data stored in the meter for customers and consumers.
Note: A mechanical gas meter equipped with an earthquake sensor plus an electrical powered
valve is not considered to be an electronic gas meter.
Note: National bodies may require components to be marked with the model(s) of the meter(s)
to which they may be attached and may require such exchange to be carried out by
authorized persons.
Note: This requirement refers to stationary operating conditions. This condition does not refer
to the response of the gas meter to changed flowrates.
3.2 FLOW DIRECTION
![Page 11: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/11.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 11/48
OIML R 137-1: 2006 (E)
3.3 PRESSURE TAPPINGS
3.4 INSTALLATION CONDITIONS
![Page 12: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/12.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 12/48
OIML R 137-1: 2006 (E)
4 Seals and markings
4.1 MEASUREMENT UNITS
4.2 MARKINGS AND INSCRIPTIONS
t min – t max
pmin – pmax
Note: The pulse value is given to at least six significant figures, unless it is equal to aninteger multiple or decimal fraction of the used unit.
![Page 13: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/13.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 13/48
OIML R 137-1: 2006 (E)
t b
M
M M M
k M k M k M
k ik C C
M i M
C i M
4.3 VERIFICATION MARKS AND PROTECTION DEVICES
![Page 14: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/14.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 14/48
OIML R 137-1: 2006 (E)
Note This requirement is only necessary if the nameplate can be detached from the
meter.
![Page 15: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/15.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 15/48
OIML R 137-1: 2006 (E)
Note: Unauthorized disconnections by the user may be prevented, for example by means of adevice that prevents any measurement after disconnecting and reconnecting.
5 Metrological requirements
5.1 RATED OPERATING CONDITIONS
p p
Note: Supercritical refers to the situation where there is no distinction between the gaseous
and liquefied state of the fluid.
5.2 VALUES OFQMAX, QT ANDQMIN
QQQ
QQ QQ
5.3 ACCURACY CLASSES AND MAXIMUM PERMISSIBLE ERRORS
![Page 16: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/16.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 16/48
OIML R 137-1: 2006 (E)
Q
Q QQ
Q Q Q
* Note: National Authorities may decide whether they will implement in-service
maximum permissible errors or not
5.4 WEIGHTED MEAN ERROR (WME)
Q
WME
5.5 REPAIR AND DAMAGE OF SEALS
![Page 17: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/17.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 17/48
OIML R 137-1: 2006 (E)
6 Technical requirements
6.1 INDICATING DEVICE
Q
Q
![Page 18: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/18.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 18/48
OIML R 137-1: 2006 (E)
Note: The serial number of the associated gas meter can be used for a clear identification.
6.2 TEST ELEMENT
![Page 19: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/19.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 19/48
OIML R 137-1: 2006 (E)
Q
6.3 ANCILLARY DEVICES
6.4 POWER SOURCES
Note: Compliance with this requirement will not necessarily ensure that the gas meter will
continue to register the quantity of gas that passed through the gas meter during a
power failure.
![Page 20: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/20.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 20/48
OIML R 137-1: 2006 (E)
6.5 CHECKS, LIMITS AND ALARMS FOR ELECTRONIC GAS METERS
Note: Pulse transmission checks focus on missing pulses, or additional pulses due to
interference. Examples are double pulse systems, three-pulse systems or pulse timingsystems.
![Page 21: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/21.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 21/48
OIML R 137-1: 2006 (E)
7 Requirements for metrological controls
7.1 TEST RESULTS
k
U MPE
U MPE .
U Guide to the expression
of uncertainty in measurement k
Example: An Accuracy Class 1 gas meter is tested during type evaluation with an uncertainty
of 0.3 % (k = 2). In this case the test results can be accepted if the error is between
± (6/5 1.0 - 0.3) % = ± 0.9 %.
7.2 REFERENCE CONDITIONS
U
f
Note: High pressure tests may be performed at conditions other than reference conditions.
7.3 TYPE APPROVAL
![Page 22: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/22.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 22/48
OIML R 137-1: 2006 (E)
N
i
i
i N
Q
Q M N
M
M N
Note: Here the same specification as used in OIML R 118 [7] is adopted. For a meter with a
rangeability of 1:150, while using M=3 the number of test points is 1+3·log(150) = 7.
The first formula leads now to 7 flowrates, distributed equally on a logarithmic flowrate
scale. In any case the minimum of test points is 6.
![Page 23: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/23.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 23/48
OIML R 137-1: 2006 (E)
Q Q Q
![Page 24: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/24.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 24/48
OIML R 137-1: 2006 (E)
Note Examples are the type of gas to be used, zeroing of coriolis meters or the use of specific
flowrates.
7.4 TYPE EXAMINATION TESTS
Table 4 Test program and requirements
Test ClauseMinimumnumber
of samples
Requirement
e
t t t t
e
e
e
e Q
e
e
e
e
e
Note: e is defined in 2.2.10.
![Page 25: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/25.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 25/48
OIML R 137-1: 2006 (E)
Note The number of degrees of freedom is the difference between the number of observations
and the number of parameters or coefficients needed for the curve fit. For example, if a
Straatsma polynomial is used with 4 coefficients, at least 10 measuring points are
necessary in order to get a minimum of 6 degrees of freedom.
Q
Q
![Page 26: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/26.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 26/48
OIML R 137-1: 2006 (E)
Example: The unsuppressed flowrate output of an Accuracy Class 1 gas meter is changed
with +1 l/h due to temperature variations. The initial error at reference conditions
of this meter was + 0.3 % at a Qmin of 200 l/h. The influence due to temperature
variations at Qmin is 1/200 × 100 % = + 0.5 %. The final value of + 0.8 % remainswithin the limits of the applicable maximum permissible error.
Qt Qmax
![Page 27: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/27.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 27/48
OIML R 137-1: 2006 (E)
Note: Instead of the above-mentioned temperature test some authorities may require the
following test.
The flow tests are performed at Qt while using the following temperatures:
Maximum ambient temperature and a gas temperature 30 °C below this ambient
temperature; Minimum ambient temperature and a gas temperature 30 °C above this ambient
temperature.
The error shall be within the limits of the double maximum permissible error as stated in 5.3.
Q
Q
![Page 28: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/28.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 28/48
OIML R 137-1: 2006 (E)
Q
Q
Example The verification is intended to be performed with air while the operating conditions
are with natural gas.
Qt
Q>Qt
![Page 29: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/29.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 29/48
OIML R 137-1: 2006 (E)
Note: Mostly, electronic meters have a cut-off for low flowrates. This cut-off must be switched
off for this test so that the flowrate output corresponds to the unsuppressed flowrate.
![Page 30: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/30.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 30/48
OIML R 137-1: 2006 (E)
Test Clause I/DMinimum No.
of samplesRequirement
e
e
e
e
e
e
e
e
e
Note:
![Page 31: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/31.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 31/48
OIML R 137-1: 2006 (E)
7.5 INITIAL VERIFICATION AND SUBSEQUENT VERIFICATION
Notes: 1. For a diaphragm meter, verification may be performed at Qmax , 0.2·Qmax and Qmin.
2. Countries may also decide to use a reduced number of test points for rotary piston
gas meters.
![Page 32: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/32.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 32/48
OIML R 137-1: 2006 (E)
Notes: After changing the adjustment while using single point adjustment it is not necessary
to repeat all the tests. It is sufficient to repeat a test at one flowrate and calculate the
other error values from the previous ones.
For high-pressure applications adjustment is performed while taking into account the
operating conditions.
7.6 ADDITIONAL REQUIREMENTS FOR STATISTICAL VERIFICATIONS
Note: National or regional authorities may decide whether the use of statistical methods is
allowed or not.
Note: The number of samples can be freely chosen, taking into account the requirement in
7.6.3. From the table at the end of 7.6.3 it follows that the minimum number of samples
is 40.
Note: This requirement gives the testing laboratory substantial freedom in organizing the test.
Examples are given in the table below. If 70 meters are tested and 1 meter appears to be
non-conforming on one of the attributes, the lot passes.
![Page 33: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/33.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 33/48
OIML R 137-1: 2006 (E)
7.7 ADDITIONAL REQUIREMENTS FOR IN-SERVICE INSPECTIONS
![Page 34: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/34.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 34/48
OIML R 137-1: 2006 (E)
Annex A
Environmental tests for electronic instruments or devices
(Mandatory)
A.1 General
A.2 Severity levels
A.3 Reference conditions
![Page 35: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/35.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 35/48
OIML R 137-1: 2006 (E)
A.4 Performance tests (climatic)
A.4.1 Static temperatures
A.4.1.1 Dry heat
A.4.1.2 Cold
A.4.2 Damp heat
A.4.2.1 Damp heat, steady-state (non condensing)
![Page 36: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/36.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 36/48
OIML R 137-1: 2006 (E)
A.4.2.2 Damp heat, cyclic (condensing)
A.5 Performance tests (mechanical)
A.5.1 Vibration (random
![Page 37: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/37.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 37/48
OIML R 137-1: 2006 (E)
A.5.2 Mechanical shock
A.6 Performance tests (electrical, general)
A.6.1 Radio frequency immunity tests
A.6.1.1 Radiated, radio frequency, electromagnetic fields
![Page 38: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/38.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 38/48
OIML R 137-1: 2006 (E)
A.6.1.2 Conducted radio-frequency fields
A.6.2 Electrostatic discharge
![Page 39: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/39.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 39/48
OIML R 137-1: 2006 (E)
A.6.3 Bursts (transients) on signal, data and control lines
A.6.4 Surges on signal, data and control lines
A.7 Performance tests (electrical, mains power)
A.7.1 DC mains voltage variation
![Page 40: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/40.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 40/48
OIML R 137-1: 2006 (E)
A.7.2 AC mains voltage variation
U
U
U
A.7.3 AC mains voltage dips, short interruptions and voltage variations
![Page 41: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/41.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 41/48
OIML R 137-1: 2006 (E)
A.7.4 Bursts (transients) on AC and DC mains
A.7.5 Surges on AC and DC mains lines
A.8 Performance test (battery powered instrument)
A.8 Low voltage of internal battery (not connected to the mains power
![Page 42: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/42.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 42/48
OIML R 137-1: 2006 (E)
42
Annex B: Flow disturbance tests(Mandatory)
B.1 General
B.1.1 The test specified in this Annex shall be carried out with air at atmospheric pressure, at flowrates of 0.25Qmax, 0.4Qmax andQmax. Alternatively, the test is performed with natural gas at pmin in case thisvalue is higher than the atmospheric pressure.
B.1.2 If the design of the type of the gas meter is similar for all pipe sizes, it is sufficient to perform the teston two sizes.
B.2 Mild flow disturbances
B.2.1 The piping configurations (see Figures 1a and 1b) consist of a pipe with a nominal diameter DN1, andwith a length of 5 DN1, two elbows with radius DN1, not in the same plane, and a concentric expanderwith diameter DN1 and DN and a length between DN and 1.5 DN.
Figure 1: Piping configurations for mild flow disturbances
![Page 43: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/43.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 43/48
OIML R 137-1: 2006 (E)
43
The values of DN1, in relation to the values of DN are listed in the following Table:
DN (meter)(mm)
DN1 (pipe)(mm)
5080100150200250300400
5006007501000
405080100150200250300
400500600750
For smaller or bigger sizes decimal multiples are used of the values stated in the table.
B.2.2 The test shall be carried out with the piping configurations as described in B.2.1 installed 2 DNupstream of the meter inlet (see Figure 1c), or with a longer upstream straight pipe and/or flowconditioner if so specified by the manufacturer.In the latter case the necessary upstream straight pipe and/or flow conditioner shall be considered partof the approved type and specified in the approval certificate.
B.2.3 During the test the shift of the error curve of the meter shall not exceed 0.33 %.
B.3 Severe flow disturbances
B.3.1 The same piping configuration as specified in B.2.1 is used with the addition of a half pipe area plateas shown in Figure 2 installed between the two elbows with the opening toward the outside radius of the first bend.
Figure 2: Half pipe area plate for severe flow disturbances
B.3.2 The provisions of B.2.2 and B.2.3 apply accordingly.
![Page 44: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/44.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 44/48
OIML R 137-1: 2006 (E)
44
Figure 3: Three-dimensional representation of Figures 1 and 2
![Page 45: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/45.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 45/48
OIML R 137-1: 2006 (E)
Annex C
Overview of tests applicable for different metering principles
(Informative)
C.1 General
![Page 46: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/46.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 46/48
OIML R 137-1: 2006 (E)
![Page 47: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/47.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 47/48
OIML R 137-1: 2006 (E)
Annex D
Bibliography
Gas metering
![Page 48: OIML R 137 1](https://reader030.vdocuments.site/reader030/viewer/2022020715/577cd6ea1a28ab9e789d8d4a/html5/thumbnails/48.jpg)
7/27/2019 OIML R 137 1
http://slidepdf.com/reader/full/oiml-r-137-1 48/48
OIML R 137-1: 2006 (E)