oil mist eliminator - filters · 2019-08-26 · working process oil mist is retained by mean of a...

8
HEAD OFFICE: REGISTERED OFFICE: PRODUCTION FACILITIES: WEB ADDRESS: 10060 Scalenghe (TO) ITALY 10121 TORINO -Via Circonvallazione, 28 – 10060 BURIASCO (TO) URL: http://www.filters.it Tel. (+39) 011-9866231 Cap. Sociale 520.000,00€ -S.Statale 23 Km 28.5 Fraz. Viotto – 10060 Scalenghe (TO) e-mail: [email protected] Fax. (+39) 011-9866310 C.C.I.A.A. Torino 738618 -Regione Botteghe, 28 – 10060 Scalenghe Regione Botteghe, 28 C.F./IVA 05826680018 C.so Vinzaglio, 12 bis FILTERS ® OIL MIST ELIMINATOR LWC SERIES Lube oil Reservoirs of Rotating machines (such as Gas or Steam Turbines, gearboxes, Compressors, Diesel Engines) relese an air flow, containing high concentration of oil mist, that needs to be evacuated to Atmosphere. LWC OME ADVANTAGES - ENVIRONMENTAL The system fulfils the most strict environment specifications. The emission quantity of oil mist is less than 5mg/M 3 - COST SAVING Within a year, thousands of litres of oil can be lost by the machinery. “LWC separator systems” allow recovered oil to normally return to the system. - OPERATING ADVANTAGES A mechanical self regulating valve, of property design, compensates the variation of the pressure loss of the system, keeping the same starting value of the vacuum in the tank. Therefore, no extra adjustment are required after start- up.

Upload: others

Post on 11-Mar-2020

8 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Oil Mist Eliminator - Filters · 2019-08-26 · Working process Oil mist is retained by mean of a special designed coalescing element, using direct interception and diffusion for

HEAD OFFICE: REGISTERED OFFICE: PRODUCTION FACILITIES: WEB ADDRESS:

10060 Scalenghe (TO) ITALY 10121 TORINO -Via Circonvallazione, 28 – 10060 BURIASCO (TO) URL: http://www.filters.it Tel. (+39) 011-9866231 Cap. Sociale 520.000,00€ -S.Statale 23 Km 28.5 Fraz. Viotto – 10060 Scalenghe (TO) e-mail: [email protected] Fax. (+39) 011-9866310 C.C.I.A.A. Torino 738618 -Regione Botteghe, 28 – 10060 Scalenghe Regione Botteghe, 28 C.F./IVA 05826680018

C.so Vinzaglio, 12 bis

FILTERS®

OIL MIST ELIMINATOR

LWC SERIES

Lube oil Reservoirs of Rotating machines (such as Gas or Steam Turbines, gearboxes, Compressors, Diesel Engines) relese an air flow, containing high concentration of oil mist, that needs to be evacuated to Atmosphere.

LWC OME ADVANTAGES

- ENVIRONMENTAL The system fulfils the most strict environment specifications. The emission quantity of oil mist is less than 5mg/M3 - COST SAVING

Within a year, thousands of litres of oil can be lost by the machinery. “LWC separator systems” allow recovered oil to normally return to the system. - OPERATING ADVANTAGES

A mechanical self regulating valve, of property design, compensates the variation of the pressure loss of the system, keeping the same starting value of the vacuum in the tank. Therefore, no extra adjustment are required after start-

up.

Page 2: Oil Mist Eliminator - Filters · 2019-08-26 · Working process Oil mist is retained by mean of a special designed coalescing element, using direct interception and diffusion for

Working process Oil mist is retained by mean of a special designed coalescing element, using direct interception and diffusion for the smallest droplets. Droplets are captured by the fibres and join together, becoming larger, slide off and drain through the coalescing media.

About mist forming Forming of oil mist in the air is primerely determined by agitation, compression and expansion of lube oil in the system. Other influencing factors: • Air or N2 Buffer gas injection in the bearing seal gas turbines have normally seal air flow • Temperature of both Air vent and Oil higher temperature reduces oil viscosity and facilitates production of smaller droplets • Oil Tank Internal Pressure

• Oil type & additives

Page 3: Oil Mist Eliminator - Filters · 2019-08-26 · Working process Oil mist is retained by mean of a special designed coalescing element, using direct interception and diffusion for

TECHNICAL FEATURES

Design da ta

Hand l ed F lu i d : Ven t A i r + o i l m i s t ;

O i l t y pe : M i nera l o r syn t he t i c o i l s

Vesse l des i gn P ress . /Temp . : 0 . 5 ba rg / 100 °C

O i l con t en t a t t he i n l e t : up to 1 ,5

Res i dua l o i l c on t en t i n t he a i r v en t ou t l e t : 5 mg /Nm 3 ;

Expec t ed d i s t r i bu t i on o f pa r t i c l es :

Mist d rop le ts d imension range (µm)

Percen tage in we igh t

2 ,5 - 1 , 5 3 – 11%

1 , 5 - 1 5 – 10%

1 - 0 , 5 9 – 14%

0 , 5 - 0 , 25 53%

0 , 25 and sma l l e r 12 – 30%

OME i s manu fac tu red a t pe r f ec t wo rkmansh i p , w i th the bes t p rac t i c es , f ree o f de f ec ts o f any k i nd .

We ld i ng and NDE exami na t i on a re execu ted by qua l i f i ed pe rsonne l .

SAVE VALUABLE

LUBE OIL

WITH OIL MIST

ELIMINATORS

Series LWC

Page 4: Oil Mist Eliminator - Filters · 2019-08-26 · Working process Oil mist is retained by mean of a special designed coalescing element, using direct interception and diffusion for

OIL MIST ELIMINATOR FEATURES LOW FLOW RATE : UP TO 100 NM3/H Single blower – On request double blower can be sup plied

SCHEMATIC DIAGRAM P&ID

Legend: TP1: Air/Oil mist eliminator INLET. TP2: Clean Air OUTLET MP1: Oil return point. MP2: Waste drain Maintenance point SV1: Oil mist eliminator Vessel, design pressure 0.05 barG / 100°C (not subjected @ European Pressure Equipment Directive (PED 97/23) PG-1: Inlet Vacuum Gauge to check the oil tank depressure PG-2: Delivery Vacuum Gauge to check the blower exhauster negative pressure V01: Adjustable Self regulating & flow control (recycle) valve to maintain constant the vacuum set in the oil tank

compensating the pressure loss variation in the system. V02: Bypass check valve, opening set ≤ 20 mmH2O SG: Sight Glass

Page 5: Oil Mist Eliminator - Filters · 2019-08-26 · Working process Oil mist is retained by mean of a special designed coalescing element, using direct interception and diffusion for

Code Flow rate

Nm3h INLET OUTLET DRAIN A B C D E F

LWC050 0 to 50 1”1/2 #150 1”1/2 #150 ¾” NPT 860 650 180 680 1000 70

LWC100 50 to 100 2” #150 2” #150 ¾” NPT 1167 650 180 680 610 70

DIMENSIONAL TABLE

Code POWER

INSTALLED

RATED

FREQUENCY

CARTRIDGES

QTY WEIGHTS kgs

LWC050 1.1kw 50hz 1 110

LWC100 1.5kw 50hz 1 130

LWC050 2HP 60hz 1 120

LWC100 3HP 60hz 1 140

OIL MIST ELIMINATOR DIMENSIONS LOW FLOW RATE : UP TO 100 NM3/H

Ed.06-09

Page 6: Oil Mist Eliminator - Filters · 2019-08-26 · Working process Oil mist is retained by mean of a special designed coalescing element, using direct interception and diffusion for

SCHEMATIC DIAGRAM P&ID

Legend: TP1: Air/Oil mist eliminator INLET. TP2: Clean Air OUTLET MP1: Oil return point. MP2: Waste drain Maintenance point SV2: Oil mist eliminator Vessel, design pressure 0.05 barG / 100°C (not subjected @ European Pressure Equipment Directive (PED 97/23) PG-1: Inlet Vacuum Gauge to check the oil tank depressure PG-2: Delivery Vacuum Gauge to check the blower exhauster negative pressure V01: Adjustable Self regulating & flow control (recycle) valve to maintain constant the vacuum set in the oil tank compensating the

pressure loss variation in the system. V02: Bypass check valve, opening set ≤ 20 mmH2O SG: Sight Glass

OIL MIST ELIMINATOR FEATURES MEDIUM FLOW RATE : UP TO 500 NM3/H Single blower – On request double blower can be sup plied

Page 7: Oil Mist Eliminator - Filters · 2019-08-26 · Working process Oil mist is retained by mean of a special designed coalescing element, using direct interception and diffusion for

OIL MIST ELIMINATOR DIMENSIONS MEDIUM FLOW RATE : UP TO 500 NM3/H

Code ITEM

Flow rate Nm3h

FREQUENCY HZ

INLET OUTLET OIL

RETURN Power

installed Qty of

cartridges Weight

LWC160 3 100 to 160 3” #150 3”#150 ¾”NPT 2.2 kw 2 290 kgs

LWC300 4 160 to 300 3” #150 3”#150 ¾”NPT 4 kw 4 360 kgs

LWC350 5 300 to 350 4” #150 4” #150 ¾”NPT 4 kw 4 380 kgs

LWC500 6 350 to 500

50hz

6” #150 6” #150 ¾”NPT 5.5 kw 6 410 kgs

LWC200 7 100 to 200 3” #150 3” #150 ¾”NPT 5hp 2 290 kgs

LWC350 8 200 to 350 4” #150 4” #150 ¾”NPT 7.5 hp 4 360 kgs

LWC500 9 350 to 500

60hz

6” #150 6” #150 ¾”NPT 10 hp 6 410 kgs

Code ITEM A B C D E F G H L M LWC160 3 1000 500 170 350 170 1250 920 300 120 370

LWC300 4 1200 500 170 350 170 1250 920 300 120 370

LWC350 5 1200 500 170 350 170 1250 920 300 110 360

LWC500 6 1200 500 290 480 290 1250 920 290 110 360

LWC200 7 1000 500 170 350 170 1250 920 300 120 370

LWC350 8 1000 500 170 350 170 1250 920 300 110 360

LWC500 9 1200 500 290 480 290 1250 920 290 110 360

Page 8: Oil Mist Eliminator - Filters · 2019-08-26 · Working process Oil mist is retained by mean of a special designed coalescing element, using direct interception and diffusion for

Our commitment to excellence is your path to success

Head offices

Regione Botteghe, 28 10060 Scalenghe (Torino) ITALY

Phone +39 011.9866231

Fax +39 011.9866310 [email protected]