    Issue 2.6 (01-01) Page 1 of 15 Product Manager: E.Visser

    FIST Ordering Guide

    FIST

    Fiber Infrastructure System Technology

    Generic Racks (FIST-GR)

    This document provides assistance with the selection of racks foruse in FIST applications.

    It includes the following sections:

    1. PRODUCT DESCRIPTION2. ORDERING INFORMATION

    2.1 Generic Rack Alternatives2.2 Accessories2.3 Tools

    3. PRODUCT GUIDE3.1 Rack Description

    3.2 Rack Dimensions and Capacity3.3 Accessories Description

    Please consult your local sales engineer for applications not included in this document.

  • 7/27/2019 oggr

    2/15

    FIST-GR Ordering Guide

    Issue 2.6 (01-01) Page 2 of 15 Product Manager: E.Visser

    Generic Racks (FIST-GR)

    1. PRODUCT DESCRIPTION

    The FIST Generic Rack, FIST-GR, is an all-purpose metal rack designed to accommodate theFIST generic shelf family.

    The FIST-GR complies with metric ETSI specifications; 19 equipment shelves can also be

    installed.

    The FIST-GR is built around 2 modular units: base frame and side duct, which can be

    combined to create different layouts.

    side duct

    base frame

    side duct

    cable and pigtail

    patchcord

    entrance

    pigtail storage

    drum

    pigtail

    containmentbracket

    horizontal

    pigtail

    management

    (HPM)

    cable and

    pigtail/patchcord

    entrance

    space

    for

    shelves

    +

    pigtail duct

    base duct system

    cable element

    management tray

    space

    for

    shelves

    RAIG022.JPG

    FIST-GR Generic Rack

  • 7/27/2019 oggr

    3/15

    FIST-GR Ordering Guide

    Issue 2.6 (01-01) Page 3 of 15 Product Manager: E.Visser

    2. ORDERING INFORMATION

    2.1 GENERIC RACKALTERNATIVES

    The following rack configurations are available. Refer to Section 3 for full product

    descriptions.

    Height

    Rack Lay out (Ref. 3.1.3)

    Bottom Plate (Ref. 3.1.4)

    Covers (Ref. 3.1.5)

    Side Duct Contents (Ref. 3.1.7)

    A

    S

    Bottom plate + adjustable feet

    Bottom plate only

    : 1.7 m

    : 2.2 m

    For the selection of the XY code,

    see Section 3.1.3

    N

    S

    D

    L

    T

    E

    M

    No covers

    Covers for all sides, HPM and base duct system,

    no front door

    Covers as option S, front door without lock

    Covers as option S, front door with lock

    Line-up configuration for option S

    Line-up configuration for option D

    Line-up configuration for option L

    Mounting (Ref. 3.1.6)

    G

    I

    Metric back (ETSI)

    Imperial back (19)

    N

    1

    2

    3

    None

    100% with drums and brackets

    The right-hand duct is fitted with drums and brackets

    100% at front, dummy back

    Cable and Pigtail Management (Ref. 3.1.8)

    N

    H

    D

    B

    None

    HPM only

    Base duct only

    Both HPM and base duct

    Packing (Ref. 3.1.9)B Pre-assembled in crate

    FIST-GR-X XY-X X-X X X-X

    1

    2

  • 7/27/2019 oggr

    4/15

  • 7/27/2019 oggr

    5/15

  • 7/27/2019 oggr

    6/15

    FIST-GR Ordering Guide

    Issue 2.6 (01-01) Page 6 of 15 Product Manager: E.Visser

    Pigtail Duct

    The bottom of the base frame contains a pigtail and

    patch cord duct system that is used to carry pigtails

    and patch cords from one side duct to the other, or

    from one rack to another in a back-to-backconfiguration.

    RAIG031.JPG

    3.1.2 Side Duct

    A side duct consists of a bottom, a back and a top which can be mounted on the left, right or

    both sides of the base frame.It is used to manage and house cable, pigtails and patchcords between shelves.

    Cable and Pigtail/Patchcord Entrance

    Facilities are available for cable entry via the top or the

    bottom of each of the side ducts.

    As delivered, the top entrance is covered with a

    removable plate.

    RAIG027.JPG

    Pigtail Containment Bracket

    Optionally, pigtail containment brackets can be fitted

    at regular intervals on the plate so that cables and

    pigtails can be secured neatly and separated from the

    flex tubes.

    RAIG028.JPG

    Pigtail Storage Drums

    Optionally, pigtail storage drums can be fitted on the

    side ducts. These allow pigtail/patchcord overlength

    storage for inter-rack patching (bottom section of side

    duct) and overlength storage for outgoing pigtails (top

    section).

    RAIG029.JPG

    pigtail containment bracket

  • 7/27/2019 oggr

    7/15

    FIST-GR Ordering Guide

    Issue 2.6 (01-01) Page 7 of 15 Product Manager: E.Visser

    3.1.3 Rack Layout

    a) Rack Layout

    The choice of layout depends upon the specific application and the location of theinstallation

    Key: Side duct 300 x 150 x 2200 or 1700 mm

    Base frame 300 x 600 x 2200 or 1700 mm

    b) Rack Type: XY

    X = 3 300 mm deep frame with or without side ducts

    depending on the choice of option Y.Shelf units mount from the front only.

    X = 6 600 mm deep frame with or without side ducts.

    Shelf units are mountable on both sides, except

    for side ducts option 3 (Ref 3.1.7) where shelf

    units are front-mounted and there is a dummy

    back.

    OR

    Y = 6 No side ducts.

    The unit is 600 mm wide.

    Y = 7 Side duct on one side only.

    The unit is 750 mm wide

    Y = 9 Side ducts on both sides.

    The total width is 900 mm.

  • 7/27/2019 oggr

    8/15

    FIST-GR Ordering Guide

    Issue 2.6 (01-01) Page 8 of 15 Product Manager: E.Visser

    3.1.4 Bottom Plate

    Order Ref. Description

    S

    A

    Bottom with pre-drilled holes for fixing to a

    smooth, horizontal floor or to a rail system.

    Bottom with adjustable feet.

    Note: This option cannot be used with rack

    layout 36 or 66.

    RAIG032.JPG

    3.1.5 Covers

    Order Ref. Description

    N

    S

    D

    L

    T

    E

    M

    None, no covers supplied with the rack.

    Covers included for all sides, horizontal

    pigtail management system (HPM) and base

    duct system.

    No front door.

    Covers included for all sides as for option S.

    A front doorwithout a locking mechanism

    is also supplied.

    The door covers the front of the shelf

    mounting bay.

    Covers included for all sides as for option S.

    A front doorwith a locking mechanism is

    also supplied.

    The door covers the front of the shelf

    mounting bay.

    As for option S but for in-line installed

    racks

    As for option D but for in-line installed

    racks.

    As for option L but for in-line installedracks.

    RAIG023.JPG

    Note: Options D and L cannot be used with rack layouts 36 and 37, nor 66 and 67.

    Use covers only - option S - or no covers at all - option N.

    3.1.6 Mounting

    Order Ref. Description

    G Vertical mounting profiles with ETSI pitch.

    Distance between profiles according to ETSI.

    I Vertical mounting profiles with ETSI pitch.

    Distance between profiles according to 19.

  • 7/27/2019 oggr

    9/15

    FIST-GR Ordering Guide

    Issue 2.6 (01-01) Page 9 of 15 Product Manager: E.Visser

    3.1.7 Side Ducts

    Order Ref. Description

    N The side ducts are supplied without any

    drums or brackets on the back plate.1 All side ducts are fitted with drums and

    brackets.

    2 One side duct (on the right) is fitted with

    drums and brackets

    3 In a back-to-back assembly, only the front

    rack has the side ducts fitted with drums and

    brackets. The other rack is an empty

    dummy.

    3.1.8 Cable Element and Pigtail ManagementOrder Ref. Description

    H The horizontal pigtail management system

    (HPM) is provided (as viewed from the

    front of the rack).

    This unit can be reversed in the field if

    desired and/or moved to a different position

    in the rack (higher or lower).

    RACA043.JPG

    D The base duct system, including the cableelement management tray and the pigtail

    duct is provided.

    RAIG033.JPG

    B Both options H and D are provided.

    N No HPM and no base duct system are supplied.

    3.1.9 Rack Packing

    Order Ref. Description

    B Shipped fully assembled in a reinforced

    cardboard crate, mounted horizontally on a

    wooden pallet.

    RA14.JPG

  • 7/27/2019 oggr

    10/15

    FIST-GR Ordering Guide

    Issue 2.6 (01-01) Page 10 of 15 Product Manager: E.Visser

    3.2 RACK DIMENSIONS AND CAPACITY

    This depends upon the options selected, some examples are given below:

    FIST-GR-239 FIST-GR-137Dimensions

    Height

    Depth

    Width

    2200 mm

    300 mm

    900 mm

    1700 mm

    300 mm

    750 mm

    Weight

    empty rack with doors packaging Approx. 125 kgApprox. 45 kg Approx. 100 kgApprox. 45 kgCable capacity

    Standard number of cables Maximum number of cables 612

    (6 in each side duct requires an

    extra cable termination kit)

    6

    6(no extra cable termination kit

    required)

    Capacity (in ETSI HUs)

    Total available ETSI HUs (25 mm pitch) 80 60

    Capacity (in #### FIST shelves) 16 12

    3.2.1 Height occupancy of FIST systems:

    FIST System Height occupancy

    (ETSI HUs)

    Base duct 8

    CEMT with cover 5Base duct with CEMT and cover 13

    HPM, HPS 7

    POM, Raychem standard shelves 5

    Raychem 44 mm high shelves 2

    Raychem 88 mm high shelves 4

    For typical arrangements with FIST elements and shelves refer to the FIST-GR installation

    instructions.

    With reference to the table above, the capacity of the other FIST-GR racks are as follows:

    Rack Capacity

    FIST-GR-X69 Twice FIST-GR-X39

    FIST-GR-X67 Twice FIST-GR-X37

    (except if side ducts option 3 is selected, then the rack capacity is the same)

  • 7/27/2019 oggr

    11/15

    FIST-GR Ordering Guide

    Issue 2.6 (01-01) Page 11 of 15 Product Manager: E.Visser

    3.3 ACCESSORIES DESCRIPTION

    The following accessories are ordered separately:

    3.3.1 Cable InstallationFlexible Tubing

    FIST-GS-FLEX-17-50-S5027

    When guiding loose tubes from the cable termination in

    the rack to the entrance of the shelf, flexible tubing is

    used to protect the loose tubes and to control the bend

    radius.

    The flexible tubing has a minimum inner diameter of 17

    mm and a capacity of up to 8 loose tubes.RA11.JPG

    Flexible Tube Clamps

    FISTV-FTC

    A set of 10 plastic clamps to be used instead of tie-wraps

    to secure flexible tubes onto the cable element

    management tray or other locations.

    FTC.JPG

    Tie Wraps

    FISTV-TW-NN-188

    188 mm long tie wraps are used for fixing the cable and

    flexible tubing to the rack.I&C025.JPG

    Cable Shield Grounding Kit

    FIST-GR-CSGK

    Consists of a plate with 6 grounding points for cable

    shields.

    The plate can be installed in the top or bottom cable

    entrance locations.

    The grounding wire and the connection with the cable

    shield depend on the cable construction and are not

    included in the kit.

    GR-CSGK.JGP

    Extra Cable Termination Kit

    FIST-GR-ECTK

    This plate can be added in a rack to extend the capacity

    with 4 or 6 additional cable terminations depending upon

    which cable attachment rail is selected (see below).

    GR-ECTK.JPG

  • 7/27/2019 oggr

    12/15

    FIST-GR Ordering Guide

    Issue 2.6 (01-01) Page 12 of 15 Product Manager: E.Visser

    Cable Attachment Rail

    FIST-GR-CAR-128-1622

    This consists of a rail and cable clamps to be mounted on

    a cable termination plate: FIST-GR-ECTK.

    It allows 4 cables (16-22 mm) to be attached viaindividual cable clamps instead of tie-wraps.

    To clamp 6 cables (12-16 mm), use

    FIST-GR-CAR-128-1216.

    GR-CAR.JPG

    Multiple Cable Termination Kit

    FIST-GR-MCTK

    This consists of a split level plate to be mounted on the

    cable element management tray.

    It allows cables to be attached via individual cable clampson both levels.

    Depending upon which cable attachment rail is used (see

    below), either 2 x 8 or 2 x 10 cables can be secured.

    GR-MCTK.JPG

    Cable Attachment Rail

    FIST-GR-CAR-215-1622

    This kit allows 7 additional cables (16-22 mm) to be

    attached via individual cable clamps on any level of themultiple cable termination kit.

    To clamp10 cables (12-16 mm) use the

    FIST-GR-CAR-215-1216.

    GR-CAR.JPG

    Cable Termination Eyelet

    FISTV-E7531-0169

    Bags of 50 crimpable eyelets to terminate cable strength

    members (2.5-4 mm).These eyelets can then be attached with a screw to the

    cable termination plate. IC&CC100.JPG

  • 7/27/2019 oggr

    13/15

    FIST-GR Ordering Guide

    Issue 2.6 (01-01) Page 13 of 15 Product Manager: E.Visser

    3.3.2 Pigtail Management

    Pigtail Back Feed-through

    FIST-GR-PBFT

    The back feed-through provides access between back-to-back racks for pigtails and patchcords.

    It is installed in the center of the base frame.

    Each kit contains components for one 300 x 600 mm base-

    frame.

    RAIG024.JPG

    Pigtail Orientation Module

    FIST-GR-POM

    A 5 ETSI HU high module with cover to be inserted in a

    rack allowing to redirect or branch a pigtail bundle.It also exists in 19 width (FIST-GR-POM-I).

    RAIG039.JPG

    Horizontal Pigtail Management

    FIST-GR-HPM

    A horizontal pigtail management system (HPM) with

    cover can be fitted to store overlengths of patchcords for

    patching within the same rack. The system can be fitted in

    the rack for either left or right patchcord entrance by

    simply turning it upside down.

    It also exists in 19 width (FIST-GR-HPM-I). RACA043.JPG

    3.3.3 Other Accessories

    Cable Entrance Dust Protection

    FIST-GR-CEDP

    Dust protection consists of a set of 6 brushes designed to

    minimize dust ingress via the cable and pigtails entrance.

    Each kit will protect 2 cable entrance openings.

    RA08.JPG

    Grounding Kit

    FIST-GR-GK

    Provides all the components to connect all rack covers

    together for grounding purposes.

    Connections are made with 2.5 mm2, yellow/green color

    coded wires.

    Grounding of the shelves to the rack is provided via the

    shelf mounting brackets.

    Each kit contains components for up to one

    300 x 900 x 2200 mm rack.

    RA07.JPG

  • 7/27/2019 oggr

    14/15

    FIST-GR Ordering Guide

    Issue 2.6 (01-01) Page 14 of 15 Product Manager: E.Visser

    Mounting Bracket for 19 equipment shelf

    FIST-GR-19I-2HU (3HU, 4HU)

    This can be used to mount 19 equipment shelves in an

    ETSI rack FIST-GR (also exists for a 19 FIST-GR). The

    brackets exist in different heights (2HU, 3HU and 4HU) toallow for different sizes of equipment shelves. The depth

    positioning of the shelves in the rack can be varied.

    Each kit contains 1 pair of brackets and fixing components.

    Notes:

    Cable access should be through the front or the back ofthe equipment shelf.

    The rack does not provide controlled heat management.

    RA04.JPG

    Back-to-Back Connection Kit

    FIST-GR-BTBC

    This provides the accessories to mount a 300 mm deep

    rack back-to-back with another 300 mm deep rack.

    Each kit contains the accessories for mounting racks up to

    900 mm wide.

    RA10.JPG

    Side-to-Side Connection Kit

    FIST-GR-STSC

    Provides the accessories to mount a 300 mm deep rackside-to-side with another 300 mm deep rack.

    RAOG2001.JPG

    Bags of Drums

    FIST-GR-DRM

    Kit of 10 drums with the typical hardware to fix them to

    the back of an empty duct.

    RACA045.JPG

  • 7/27/2019 oggr

    15/15