oggr
TRANSCRIPT
-
7/27/2019 oggr
1/15
Issue 2.6 (01-01) Page 1 of 15 Product Manager: E.Visser
FIST Ordering Guide
FIST
Fiber Infrastructure System Technology
Generic Racks (FIST-GR)
This document provides assistance with the selection of racks foruse in FIST applications.
It includes the following sections:
1. PRODUCT DESCRIPTION2. ORDERING INFORMATION
2.1 Generic Rack Alternatives2.2 Accessories2.3 Tools
3. PRODUCT GUIDE3.1 Rack Description
3.2 Rack Dimensions and Capacity3.3 Accessories Description
Please consult your local sales engineer for applications not included in this document.
-
7/27/2019 oggr
2/15
FIST-GR Ordering Guide
Issue 2.6 (01-01) Page 2 of 15 Product Manager: E.Visser
Generic Racks (FIST-GR)
1. PRODUCT DESCRIPTION
The FIST Generic Rack, FIST-GR, is an all-purpose metal rack designed to accommodate theFIST generic shelf family.
The FIST-GR complies with metric ETSI specifications; 19 equipment shelves can also be
installed.
The FIST-GR is built around 2 modular units: base frame and side duct, which can be
combined to create different layouts.
side duct
base frame
side duct
cable and pigtail
patchcord
entrance
pigtail storage
drum
pigtail
containmentbracket
horizontal
pigtail
management
(HPM)
cable and
pigtail/patchcord
entrance
space
for
shelves
+
pigtail duct
base duct system
cable element
management tray
space
for
shelves
RAIG022.JPG
FIST-GR Generic Rack
-
7/27/2019 oggr
3/15
FIST-GR Ordering Guide
Issue 2.6 (01-01) Page 3 of 15 Product Manager: E.Visser
2. ORDERING INFORMATION
2.1 GENERIC RACKALTERNATIVES
The following rack configurations are available. Refer to Section 3 for full product
descriptions.
Height
Rack Lay out (Ref. 3.1.3)
Bottom Plate (Ref. 3.1.4)
Covers (Ref. 3.1.5)
Side Duct Contents (Ref. 3.1.7)
A
S
Bottom plate + adjustable feet
Bottom plate only
: 1.7 m
: 2.2 m
For the selection of the XY code,
see Section 3.1.3
N
S
D
L
T
E
M
No covers
Covers for all sides, HPM and base duct system,
no front door
Covers as option S, front door without lock
Covers as option S, front door with lock
Line-up configuration for option S
Line-up configuration for option D
Line-up configuration for option L
Mounting (Ref. 3.1.6)
G
I
Metric back (ETSI)
Imperial back (19)
N
1
2
3
None
100% with drums and brackets
The right-hand duct is fitted with drums and brackets
100% at front, dummy back
Cable and Pigtail Management (Ref. 3.1.8)
N
H
D
B
None
HPM only
Base duct only
Both HPM and base duct
Packing (Ref. 3.1.9)B Pre-assembled in crate
FIST-GR-X XY-X X-X X X-X
1
2
-
7/27/2019 oggr
4/15
-
7/27/2019 oggr
5/15
-
7/27/2019 oggr
6/15
FIST-GR Ordering Guide
Issue 2.6 (01-01) Page 6 of 15 Product Manager: E.Visser
Pigtail Duct
The bottom of the base frame contains a pigtail and
patch cord duct system that is used to carry pigtails
and patch cords from one side duct to the other, or
from one rack to another in a back-to-backconfiguration.
RAIG031.JPG
3.1.2 Side Duct
A side duct consists of a bottom, a back and a top which can be mounted on the left, right or
both sides of the base frame.It is used to manage and house cable, pigtails and patchcords between shelves.
Cable and Pigtail/Patchcord Entrance
Facilities are available for cable entry via the top or the
bottom of each of the side ducts.
As delivered, the top entrance is covered with a
removable plate.
RAIG027.JPG
Pigtail Containment Bracket
Optionally, pigtail containment brackets can be fitted
at regular intervals on the plate so that cables and
pigtails can be secured neatly and separated from the
flex tubes.
RAIG028.JPG
Pigtail Storage Drums
Optionally, pigtail storage drums can be fitted on the
side ducts. These allow pigtail/patchcord overlength
storage for inter-rack patching (bottom section of side
duct) and overlength storage for outgoing pigtails (top
section).
RAIG029.JPG
pigtail containment bracket
-
7/27/2019 oggr
7/15
FIST-GR Ordering Guide
Issue 2.6 (01-01) Page 7 of 15 Product Manager: E.Visser
3.1.3 Rack Layout
a) Rack Layout
The choice of layout depends upon the specific application and the location of theinstallation
Key: Side duct 300 x 150 x 2200 or 1700 mm
Base frame 300 x 600 x 2200 or 1700 mm
b) Rack Type: XY
X = 3 300 mm deep frame with or without side ducts
depending on the choice of option Y.Shelf units mount from the front only.
X = 6 600 mm deep frame with or without side ducts.
Shelf units are mountable on both sides, except
for side ducts option 3 (Ref 3.1.7) where shelf
units are front-mounted and there is a dummy
back.
OR
Y = 6 No side ducts.
The unit is 600 mm wide.
Y = 7 Side duct on one side only.
The unit is 750 mm wide
Y = 9 Side ducts on both sides.
The total width is 900 mm.
-
7/27/2019 oggr
8/15
FIST-GR Ordering Guide
Issue 2.6 (01-01) Page 8 of 15 Product Manager: E.Visser
3.1.4 Bottom Plate
Order Ref. Description
S
A
Bottom with pre-drilled holes for fixing to a
smooth, horizontal floor or to a rail system.
Bottom with adjustable feet.
Note: This option cannot be used with rack
layout 36 or 66.
RAIG032.JPG
3.1.5 Covers
Order Ref. Description
N
S
D
L
T
E
M
None, no covers supplied with the rack.
Covers included for all sides, horizontal
pigtail management system (HPM) and base
duct system.
No front door.
Covers included for all sides as for option S.
A front doorwithout a locking mechanism
is also supplied.
The door covers the front of the shelf
mounting bay.
Covers included for all sides as for option S.
A front doorwith a locking mechanism is
also supplied.
The door covers the front of the shelf
mounting bay.
As for option S but for in-line installed
racks
As for option D but for in-line installed
racks.
As for option L but for in-line installedracks.
RAIG023.JPG
Note: Options D and L cannot be used with rack layouts 36 and 37, nor 66 and 67.
Use covers only - option S - or no covers at all - option N.
3.1.6 Mounting
Order Ref. Description
G Vertical mounting profiles with ETSI pitch.
Distance between profiles according to ETSI.
I Vertical mounting profiles with ETSI pitch.
Distance between profiles according to 19.
-
7/27/2019 oggr
9/15
FIST-GR Ordering Guide
Issue 2.6 (01-01) Page 9 of 15 Product Manager: E.Visser
3.1.7 Side Ducts
Order Ref. Description
N The side ducts are supplied without any
drums or brackets on the back plate.1 All side ducts are fitted with drums and
brackets.
2 One side duct (on the right) is fitted with
drums and brackets
3 In a back-to-back assembly, only the front
rack has the side ducts fitted with drums and
brackets. The other rack is an empty
dummy.
3.1.8 Cable Element and Pigtail ManagementOrder Ref. Description
H The horizontal pigtail management system
(HPM) is provided (as viewed from the
front of the rack).
This unit can be reversed in the field if
desired and/or moved to a different position
in the rack (higher or lower).
RACA043.JPG
D The base duct system, including the cableelement management tray and the pigtail
duct is provided.
RAIG033.JPG
B Both options H and D are provided.
N No HPM and no base duct system are supplied.
3.1.9 Rack Packing
Order Ref. Description
B Shipped fully assembled in a reinforced
cardboard crate, mounted horizontally on a
wooden pallet.
RA14.JPG
-
7/27/2019 oggr
10/15
FIST-GR Ordering Guide
Issue 2.6 (01-01) Page 10 of 15 Product Manager: E.Visser
3.2 RACK DIMENSIONS AND CAPACITY
This depends upon the options selected, some examples are given below:
FIST-GR-239 FIST-GR-137Dimensions
Height
Depth
Width
2200 mm
300 mm
900 mm
1700 mm
300 mm
750 mm
Weight
empty rack with doors packaging Approx. 125 kgApprox. 45 kg Approx. 100 kgApprox. 45 kgCable capacity
Standard number of cables Maximum number of cables 612
(6 in each side duct requires an
extra cable termination kit)
6
6(no extra cable termination kit
required)
Capacity (in ETSI HUs)
Total available ETSI HUs (25 mm pitch) 80 60
Capacity (in #### FIST shelves) 16 12
3.2.1 Height occupancy of FIST systems:
FIST System Height occupancy
(ETSI HUs)
Base duct 8
CEMT with cover 5Base duct with CEMT and cover 13
HPM, HPS 7
POM, Raychem standard shelves 5
Raychem 44 mm high shelves 2
Raychem 88 mm high shelves 4
For typical arrangements with FIST elements and shelves refer to the FIST-GR installation
instructions.
With reference to the table above, the capacity of the other FIST-GR racks are as follows:
Rack Capacity
FIST-GR-X69 Twice FIST-GR-X39
FIST-GR-X67 Twice FIST-GR-X37
(except if side ducts option 3 is selected, then the rack capacity is the same)
-
7/27/2019 oggr
11/15
FIST-GR Ordering Guide
Issue 2.6 (01-01) Page 11 of 15 Product Manager: E.Visser
3.3 ACCESSORIES DESCRIPTION
The following accessories are ordered separately:
3.3.1 Cable InstallationFlexible Tubing
FIST-GS-FLEX-17-50-S5027
When guiding loose tubes from the cable termination in
the rack to the entrance of the shelf, flexible tubing is
used to protect the loose tubes and to control the bend
radius.
The flexible tubing has a minimum inner diameter of 17
mm and a capacity of up to 8 loose tubes.RA11.JPG
Flexible Tube Clamps
FISTV-FTC
A set of 10 plastic clamps to be used instead of tie-wraps
to secure flexible tubes onto the cable element
management tray or other locations.
FTC.JPG
Tie Wraps
FISTV-TW-NN-188
188 mm long tie wraps are used for fixing the cable and
flexible tubing to the rack.I&C025.JPG
Cable Shield Grounding Kit
FIST-GR-CSGK
Consists of a plate with 6 grounding points for cable
shields.
The plate can be installed in the top or bottom cable
entrance locations.
The grounding wire and the connection with the cable
shield depend on the cable construction and are not
included in the kit.
GR-CSGK.JGP
Extra Cable Termination Kit
FIST-GR-ECTK
This plate can be added in a rack to extend the capacity
with 4 or 6 additional cable terminations depending upon
which cable attachment rail is selected (see below).
GR-ECTK.JPG
-
7/27/2019 oggr
12/15
FIST-GR Ordering Guide
Issue 2.6 (01-01) Page 12 of 15 Product Manager: E.Visser
Cable Attachment Rail
FIST-GR-CAR-128-1622
This consists of a rail and cable clamps to be mounted on
a cable termination plate: FIST-GR-ECTK.
It allows 4 cables (16-22 mm) to be attached viaindividual cable clamps instead of tie-wraps.
To clamp 6 cables (12-16 mm), use
FIST-GR-CAR-128-1216.
GR-CAR.JPG
Multiple Cable Termination Kit
FIST-GR-MCTK
This consists of a split level plate to be mounted on the
cable element management tray.
It allows cables to be attached via individual cable clampson both levels.
Depending upon which cable attachment rail is used (see
below), either 2 x 8 or 2 x 10 cables can be secured.
GR-MCTK.JPG
Cable Attachment Rail
FIST-GR-CAR-215-1622
This kit allows 7 additional cables (16-22 mm) to be
attached via individual cable clamps on any level of themultiple cable termination kit.
To clamp10 cables (12-16 mm) use the
FIST-GR-CAR-215-1216.
GR-CAR.JPG
Cable Termination Eyelet
FISTV-E7531-0169
Bags of 50 crimpable eyelets to terminate cable strength
members (2.5-4 mm).These eyelets can then be attached with a screw to the
cable termination plate. IC&CC100.JPG
-
7/27/2019 oggr
13/15
FIST-GR Ordering Guide
Issue 2.6 (01-01) Page 13 of 15 Product Manager: E.Visser
3.3.2 Pigtail Management
Pigtail Back Feed-through
FIST-GR-PBFT
The back feed-through provides access between back-to-back racks for pigtails and patchcords.
It is installed in the center of the base frame.
Each kit contains components for one 300 x 600 mm base-
frame.
RAIG024.JPG
Pigtail Orientation Module
FIST-GR-POM
A 5 ETSI HU high module with cover to be inserted in a
rack allowing to redirect or branch a pigtail bundle.It also exists in 19 width (FIST-GR-POM-I).
RAIG039.JPG
Horizontal Pigtail Management
FIST-GR-HPM
A horizontal pigtail management system (HPM) with
cover can be fitted to store overlengths of patchcords for
patching within the same rack. The system can be fitted in
the rack for either left or right patchcord entrance by
simply turning it upside down.
It also exists in 19 width (FIST-GR-HPM-I). RACA043.JPG
3.3.3 Other Accessories
Cable Entrance Dust Protection
FIST-GR-CEDP
Dust protection consists of a set of 6 brushes designed to
minimize dust ingress via the cable and pigtails entrance.
Each kit will protect 2 cable entrance openings.
RA08.JPG
Grounding Kit
FIST-GR-GK
Provides all the components to connect all rack covers
together for grounding purposes.
Connections are made with 2.5 mm2, yellow/green color
coded wires.
Grounding of the shelves to the rack is provided via the
shelf mounting brackets.
Each kit contains components for up to one
300 x 900 x 2200 mm rack.
RA07.JPG
-
7/27/2019 oggr
14/15
FIST-GR Ordering Guide
Issue 2.6 (01-01) Page 14 of 15 Product Manager: E.Visser
Mounting Bracket for 19 equipment shelf
FIST-GR-19I-2HU (3HU, 4HU)
This can be used to mount 19 equipment shelves in an
ETSI rack FIST-GR (also exists for a 19 FIST-GR). The
brackets exist in different heights (2HU, 3HU and 4HU) toallow for different sizes of equipment shelves. The depth
positioning of the shelves in the rack can be varied.
Each kit contains 1 pair of brackets and fixing components.
Notes:
Cable access should be through the front or the back ofthe equipment shelf.
The rack does not provide controlled heat management.
RA04.JPG
Back-to-Back Connection Kit
FIST-GR-BTBC
This provides the accessories to mount a 300 mm deep
rack back-to-back with another 300 mm deep rack.
Each kit contains the accessories for mounting racks up to
900 mm wide.
RA10.JPG
Side-to-Side Connection Kit
FIST-GR-STSC
Provides the accessories to mount a 300 mm deep rackside-to-side with another 300 mm deep rack.
RAOG2001.JPG
Bags of Drums
FIST-GR-DRM
Kit of 10 drums with the typical hardware to fix them to
the back of an empty duct.
RACA045.JPG
-
7/27/2019 oggr
15/15