of elk creek elementary school renovations · 2015. 1. 13. · for of site no. 13000 1/12/2015...
TRANSCRIPT
FOR
OF
SITE NO. 13000
1/12
/201
5 10
:04:
52 A
M
ELK CREEK ELEMENTARY SCHOOL RENOVATIONS13304 South US Highway 285, Pine, Colorado, 80004
13 January 2015
DESIGN DEVELOPMENT SUBMITTAL - PHASE ONE
CONIFER
BAILEY
EVERGREEN
EL RANCHO
KITTREDGE
LITTLETON
LAKEWOOD
MORRISON
GOLDEN DENVER
WHEAT RIDGE
PINE JUNCTION ELK CREEK ELEMENTARY
HWY 285
I-25
74
I-70
HWY 285
6
I-70
I-25
C-470
Date
Drawn By
Checked By:
Project Number
Sheet Name
Copyright:
ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE
DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF
MOA ARCHITECTURE
Site
No:
130
00
PH
AS
E O
NE
1/12
/201
5 10
:04:
52 A
M
G-001
SHEET INDEX,PROJECT
DIRECTORY
EL
K C
RE
EK
EL
EM
EN
TA
RY
SC
HO
OL
RE
NO
VA
TIO
NS
Author
01.13.15
14136.00
1330
4 S
outh
US
Hig
hway
285
, Pin
e, C
olor
ado,
800
04
DESIGN DEVELOPMENT SUBMITTAL - PHASEONE
Checker
GENERALG-001 SHEET INDEX, PROJECT DIRECTORY
ARCHITECTURALAS-101 ARCHITECTURAL SITE PLAN
A-100 ELK CREEK ES MAIN AND LOWER LEVEL PLAN
A-110 ELK CREEK ES ROOF AND MECHANICAL MEZZANINE PLAN
MECHANICALM-001 MECHANICAL LEGENDS AND SCHEDULES
MD-100 MECHANICAL DEMOLITION PLANS
MD-110 MECHANICAL ROOF DEMOLITION PLAN
M-100 MECHANICAL MAIN AND LOWER LEVEL PLANS
M-110 MECHANICAL ROOF AND MEZZANINE PLAN
M-200 MECHANICAL DETAILS
M-300 CONTROL DRAWINGS
ELECTRICALE-100 ELECTRICAL ONE-LINE DIAGRAM
E-101 SITE ELECTRICAL PLAN
E-201 BUILDING ELECTRICAL PLAN
Sheet IndexTerms and Abbreviations
Project Directory
Contractor:
12560 West Cedar Drive
Himmelman Construction
Lakewood, Colorado 80228V: 303.790.1984
Architect:
MOA Architecture
821 17th Street, Suite 400Denver, CO 80202V: 303.308.1190
Architect's Consultants: Owner:Mechanical Engineer:Civil Engineer:
9777 Pyramid Court, Suite 120Englewood, Colorado 80112V: 303.688.0223F: [email protected]
Envision Mechanical Engineers, Inc.809 Quail Street, Building No. 4Lakewood, Colorado 80215V: 303.982.2482F: [email protected]
Jeffco Public Schools
12499 West Colfax AvenueLakewood, Colorado 80215V: 303.431.6100F: [email protected]
Martin / Martin Consulting Engineers
Vicinity MapReference SymbolsMaterial Symbols
Elevation Numbers
Sheet NumberELEVATION INDICATOR:
Section NumberSheet Number
PARTIAL SECTION:
Section NumberSheet Number
DETAIL INDICATOR:
Section NumberSheet NumberBUILDING SECTION:
Section NumberSheet Number
SECTION DETAIL:
DOOR OPENING:
210A
SYSTEM NOTE:
KEYNOTE INDICATOR:
WALL PANEL CENTERLINE:
REVISION:
ELEVATION MARK:
DRAWING BLOCK:
WINDOW LOUVER TYPE:
Sheet Number
Elevation Number
Single View
Multiple View
DRAWING BLOCK TITLE
DRAWING SCALE2
CROSS REFERENCE
1
1
2
WALL PANEL TYPE:
NORTH INDICATOR:
P*
LEVEL DESCRIPTORELEVATION HEIGHT
ACCESSORY / EQUIPMENT INDICATOR:
Section NumberSheet Number
# L#
_#
#
#
2
F=FLOOR, P=PARTITIONW=WALL, C=CEILING, R=ROOF
GRAPHIC SCALE:
MATCHLINE: MATCHLINERE: ITEM NO. / SHEET NO.
TRUE
MATERIAL/FINISH INDICATOR: A-#Exterior
Interior
0 8020 40
TD TOWEL DISPENSER
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
THK THICK or THICKNESS
THRES THRESHOLD
TMPD TEMPERED
TOC TOP OF CONCRETE
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPTN TOILET PARTITION
TR TOWEL RACK
TV TELEVISION
TYP TYPICAL
U
UBC UNIFORM BUILDING CODE
UFC UNIFORM FIRE CODE
UL UNDERWRITER'S LABORATORY
UMC UNIFORM MECHANICAL CODE
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UOS UNLESS OTHERWISE SPECIFIED
UPC UNIFORM PLUMBING CODE
UR URINAL
UTIL UTILITY
V
v WALL VENEER MATERIAL
VAC VACUUM
VAR VARIES
VB VAPOR BARRIER or VINYL BASE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VFW VINYL WOOD FLOORING
VIF VERIFY IN FIELD
VIN VINYL
VOC VOLATILE ORGANIC COMPOUND
VOL VOLUME
VSF VINYL SHEET FLOORING
VT VINYL TILE
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W
W WEST
W/ WITH
W/O WITHOUT
WB WASTE BASKET or WOOD BASE
WC WALL COVERING or WATER CLOSET
WD WOOD or WOOD DOOR
WDW WINDOW
WF WIDE FLANGE
WH WEEP HOLE
WP WATERPROOF(ING), WATER PUMP,WEATHERPROOF or WORKING POINT
WR WATER REPELLANT or WEATHER RESISTANT
WSCT WAINSCOT
WT WEIGHT
WVFP WOOD VENEER FACED PANEL
WWF WELDED WIRE FABRIC
RFS RESILIENT FLOORING SYSTEM
RH RELATIVE HUMIDITY, RIGHT HAND or ROOFHATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RM ROOM
RO ROUGH OPENING
ROW RIGHT-OF-WAY
RSF RUBBER SHEET FLOORING
RST STAIR TREADS & ACCESSORIES
RT RIGHT / RUBBER TILE
RTU ROOFTOP UNIT
RUFS RESILIENT URETHANE FLOORING SYSTEM
RWC RAIN WATER CONDUCTOR
S
S SOUTH
SA SUPPLY AIR
SAB SOUND ATTENUATION BATT
SAN SANITARY
SC SOLID CORE / SHADING COEFFICIENT / SEALEDCONC
SCD SEAT COVER DISPENSER
SCF STATIC CONTROL FLOORING
SCHED SCHEDULE
SCPT CARPET - STRETCHED - IN
SD SOAP DISPENSER or SMOKE DETECTOR
SECT SECTION
SF SQUARE FOOT (FEET)
SG SAFETY GLAZING
SH SHELF or SINGLE HUNG
SHT SHEET
SHTHG SHEATHING
SHWR SHOWER
SIM SIMILAR
SJ SCORED JOINT or SLIP JOINT
SK SKETCH
SM SHEET METAL
SMACNA SHEET METAL and AIR CONDITIONINGCONTRACTOR'S NATIONAL ASSOCIATION
SMV STONE MASONRY VENEER
SPEC SPECIFICATION(S)
SPF SHAFT PRESSURIZATION FAN
SPKLR SPRINKLER
SQ SQUARE
SR SINK RECEPTACLE
SS SOLID SURFACING
SST STAINLESS STEEL
ST SLATE TILE
STA STATION
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE or STRUCTURAL
SUSP SUSPEND(ED)
SV SHEET VINYL
SYMM SYMMETRICAL
SYS SYSTEM
T
T TREAD / STONE TILE
t THERMAL INSULATION IN WALL ASSEMBLY
T&G TONGUE AND GROOVE
TB THERMAL BATT INSULATION / TOWEL BAR
TCPT CARPET TILE
NFC NATIONAL FIRE CODE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NFRC NATIONAL FENESTRATION RATING COUNCIL
NIBS NATIONAL INSTITUTE of BUILDING SCIENCES
NIC NOT IN CONTRACT
NIST NATIONAL INSTITUTE of STANDARDS andTECHNOLOGY
NO NUMBER
NOM NOMINAL
NR NON-RATED
NRC NOISE REDUCTION COEFFICIENT
NSF NATIONAL SANITATION FOUNDATION
NTS NOT TO SCALE
O
O2 OXYGEN
O/O OUT-TO-OUT
OA OVERALL
OC ON-CENTER
OD OUTSIDE DIAMETER, OUTSIDE DIMENSION orOVERFLOW DRAIN
OFF OFFICE
OH DR OVERHEAD DOOR
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
OSHA OCCUPATIONAL SAFETY and HEALTHADMINISTRATION
P
PA PUBLIC ADDRESS
PAC PRECAST ARCHITECTURAL CONCRETE
PB PAINTED BASE, PANEL BOARD, PANIC BAR, PULLBOX or PUSH-BUTTON
PCS POLISHED CONCRETE SYSTEM
PED PEDESTAL or PEDESTRIAN
PERF PERFORATED
PERIM PERIMETER
PF PREFINISHED
PL PLATE or PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTER or PLASTIC
PLYWD PLYWOOD
PMT PORCELIN MOSAIC TILE
PN PART NUMBER
PNL PANEL
PNTD PAINTED
PR PAIR or PROPOSAL REQUEST
PREFAB PREFABRICATED
PROJ PROJECT
PS PULL STATION
PSC PRECAST STRUCTURAL CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT(ED), POST-TENSIONED SLAB or PRESSURETREATED
PT PRESERVATIVE TREATED
PTE PAINT EXTERIOR
PTI PAINT INTERIOR
PTN PARTITION
PV PAVEMENT or PHOTOVOLTAIC
PVT PAVER TILE
PWR POWER
Q
QA QUALITY ASSURANCE
QT QUARRY TILE
QTY QUANTITY
R
R RADIUS, RISER or THERMAL RESISTANCE
RA RETURN AIR
RAF RUBBER ATHLETIC FLOORING
RAFS RESILIENT ATHLETIC FLOORING SYSTEM
RB RESILIENT BASE or RUBBER BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN or ROAD
RE REFER TO or REFERENCE
REBAR STEEL REINFORCING BARS
REC RECESS(ED)
REF REFRIGERATOR or REFRIGERATED
REFL REFLECTED
REINF REINFORCED
REQD REQUIRED
RESIL RESILIENT
REV REVISE, REVISED or REVISION
RFG ROOFING
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
HD HEAVY-DUTY
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATION and AIR CONDITIONING
HW HOT WATER
I
IBC INTERNATIONAL BUILDING CODE or INSTALLEDBY CONTRACTOR
ID IDENTIFICATION, INSIDE DIAMETER or INSIDEDIMENSION
IGU INSULATING GLASS UNIT [SEALED]
IN INCH
INFO INFORMATION
INSUL INSULATED or INSULATION
INT INTERIOR
INV INVERT
ISS INTEGRATED CEILING SYSTEM
J
JAN JANITOR
JT JOINT
K
KCU KITCHEN CONDENSING UNIT
KD KNOCKED DOWN
KEF KITCHEN EXHAUST FAN
KIT KITCHEN
KO KNOCKOUT
KPL KICK PLATE
L
L ANGLE
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LBL LABEL
LCS LUMINOUS CEILING SYSTEM
LF LINEAR FEET / LINOLEUM FLOORING
LH LEFT HAND
LHR LEFT HAND REVERSE
LIB LIBRARY
LKR LOCKER
LL LEAD-LINED or LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMCS LINEAR METAL CEILING SYSTEM
LR LIVING ROOM
LT LIGHT / LIMESTONE TILE
LTL LINTEL
LVR LOUVER
LWC LIGHT WEIGHT CONCRETE
LYR LAYER
M
MACH MACHINE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MBR MASTER BEDROOM
MCM METAL COMPOSITE MATERIAL PANEL
MD METAL DECK
MECH MECHANICAL
MEMB MEMBRANE
MEP MECHANICAL, ELECTRICAL and PLUMBING
MEZZ MEZZANINE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MP METAL PANEL
MSFS MODULAR SPORT FLOORING SYSTEM
MT MARBLE TILE
MTD MOUNTED
MTL METAL
MTLR METAL - RESIDENTIAL
MULL MULLION
N
N NORTH
NA NOT APPLICABLE
NC NOISE CRITERIA
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERSASSOCIATION
ENCL ENCLOSURE
ENGR ENGINEER
EOS EDGE OF SLAB
EPA ENVIRONMENTAL PROTECTION AGENCY
EPDM ETHYLENE PROPYLENE DIENE MONOMER (roofing)
EPS EXPANDED POLYSTYRENE (insulation board)
EQ EQUAL
EQUIP EQUIPMENT
ESMT EASEMENT
ETC ET CETERA (and so forth)
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPAND, EXPANDED or EXPANSION
EXPS EXPOSED STRUCTURE
EXT EXTERIOR or EXTINGUISHER
F
F FARENHEIT
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FAFS FLUID APPLIED FLOORING SYSTEM
FAR FLOOR AREA RATIO
FAS FASCIA or FASTEN(ER)
FBO FURNITURE BY OWNER or FURNISHED BY OWNER
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFE FURNITURE, FIXTURES AND EQUIPMENT
FFL FINISHED FLOOR LINE
FG FIBERGLASS
FHC FIRE HOSE CABINET
FHS FIRE HOSE STATION
FIN FINISH(ED)
FIXT FIXTURE
FL FLOOR LINE
FLASH FLASHING
FLR FLOOR
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FR FIRE RATING, FIRE RESISTIVE, FIRE RESISTANT orFRAME
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBER-REINFORCED POLYESTER orFIBERGLASS-REINFORCED PLASTIC
FRT FIRE RETARDENT TREATED
FT FEET, FOOT or FIRE TREATED
FTG FOOTING
FURN FURNACE, FURNISH or FURNITURE
FURR FURRING
FUT FUTURE
FW FIRE WALL
FWC FABRIC WALL COVERING
FWD FLUSH WOOD DOOR
FWP FABRIC WRAPPED PANEL
G
GA GAUGE or GYPSUM ASSOCIATION
GALV GLAVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GCMU GLAZED CONCRETE MASONRY UNIT(S)
GCPT CARPET - DIRECT-GLUED
GD GRADE
GFRC GLASS-FIBER-REINFORCED CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GFRP GLASS-FIBER-REINFORCED PLASTER or PLASTIC
GL GLASS or GLAZING
GLU-LAM GLUED-LAMINATED WOOD
GLZ GLAZING
GMP GUARANTEED MAXIMUM PRICE
GND GROUND
GRF GROUT RUB FINISH
GS GALVANIZED STEEL
GT GRANITE TILE
GWT GLAZED WALL TILE
GYM GYMNASIUM
GYP GYPSUM
GYP BD GYPSUM BOARD
H
HB HOSE BIBB
HC HANDICAP, HOLLOW CORE or HOSE CABINET
CD CONSTRUCTION DOCUMENTS or CONTRACTDOCUMENTS
CEM CEMENT or CEMENTITIOUS
CER CERAMIC
CERT CERTIFY or CERTIFICATE
CF CURTAIN FABRIC
CG CORNER GUARD
CHBD CHALKBOARD
CI CAST IRON
CIP CAST-IN-PLACE (CONCRETE)
CJ CONTROL JOINT - CONCRETE (CMU)
CL CENTERLINE
CLG CEILING
CLK CAULK(ED/ING)
CLL CONTRACT LIMIT LINE
CLO CLOSET
CLR CLEAR
CMT CERAMIC MOSAIC TILE
CMU CONCRETE MASONRY UNIT
CNTR COUNTER
CO CARBON MONOXIDE, CASED OPENING,CERTIFICATE of OCCUPANCY, CHANGE ORDER,CLEANOUT, COMPANY or CUTOUT
COAX COAXIAL CABLE
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONF CONFERENCE
CONN CONNECT(ION)
CONSTCONST
CONSTRUCTION
CONT CONTINUE, CONTINUOUS or CONTROLLER
CONTR CONTRACT(OR)
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPPS CONCRETE PEDESTAL PAVER SYSTEM
CPT CARPET
CRSI CONCRETE REINFORCING STEEL INSTITUTE
CSI CONSTRUCTION SPECIFICATIONS INSTITUTE
CSK COUNTERSINK or COUNTERSUNK
CSMT CASEMENT
CSS CLINICAL SERVICE SINK
CSWK CASEWORK
CT CERAMIC TILE or COUNT
CTB CERAMIC TILE BASE
CTR CENTER
CTRL CONTROL
CU CUBIC
CW CLOCKWISE
D
D DATA, DEEP, DEPTH, DRAIN or PENNY (nail)
dB DECIBEL
DBL DOUBLE
DEG DEGREE(S)
DEMO DEMOLISH or DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DH DOUBLE-HUNG
DIA DIAMETER
DIAG DIAGONAL or DIAGRAM
DIFF DIFFERENCE, DIFFERENTIAL or DIFFUSER
DIM DIMENSION or DIMENSIONAL
DISP DISPENSER
DIST DISTANCE
DIV DIVIDE or DIVISION
DN DOWN
DOC DOCUMENT
DR DINING ROOM, DOOR, DRAIN or DRIVE
DS DOWNSPOUT
DT DRAIN TILE
DW DISHWASHER
DWG DRAWING
DWR DRAWER
E
E EAST
EA EACH
ED EXHAUST DUCT
EF EXHAUST FAN
EFG ENTRANCE FLOOR GRATE / GRILLE
EIFS EXTERIOR INSULATION and FINISHING SYSTEM
EJ EXPANSION JOINT - FACE BRICK
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EM ENTRANCE MAT
EMER EMERGENCY
A
a ACOUSTIC WALL ASSEMBLY
AB ANCHOR BOLT
AC AIR CONDITION(ER/ING)
ACI AMERICAN CONCRETE INSTITUTE
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADDM ADDENDUM
ADJ ADJACENT, ADJUSTABLE or ADJOINING
AESS ARCHITECTURAL EXPOSED STRUCTURAL STEEL
AFF ABOVE FINISHED FLOOR
AFS ACCESS FLOOR SYSTEM
AGC ASSOCIATED GENERAL CONTRACTORS
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE of ARCHITECTS
AISC AMERICAN INSTITUTE of STEEL CONSTRUCTION
ALT ALTERNATE
ALUM, AL ALUMINUM
ANN ANNUNCIATOR
ANOD ANODIZED
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APA AMERICAN PLYWOOD ASSOCIATION
APCS ACRYLIC PLASTER CEILING SYSTEM
APPD APPROVED
APPROX APPROXIMATE(LY)
APS ACOUSTICAL PANEL SYSTEM
APT APARTMENT
ARCH ARCHITECT or ARCHITECTURAL
ASCE AMERICAN SOCIETY of CIVIL ENGINEERS
ASHRAE AMERICAN SOCIETY of HEATING, REFRIGERATIONand AIR CONDITIONING ENGINEERS
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS
ASID AMERICAN SOCIETY of INTERIOR DESIGNERS
ASME AMERICAN SOCIETY of MECHANICAL ENGINEERS
ASPH ASPHALT
ASSY ASSEMBLY
ASTM AMERICAN SOCIETY for TESTING and MATERIALS
ATM AUTOMATIC TELLER MACHINE
ATTN ATTENTION
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO / VISUAL
AW ARCHITECTURAL WOODWORK
AWG AMERICAN WIRE GAUGE
AWI ARCHITECTURAL WOODWORKING INSTITUTE
AWPA AMERICAN WOOD PRESERVERS ASSOCATION
AWPS ACOUSTICAL WALL PANEL SYSTEM
AWS AMERICAN WELDING SOCIETY
B
B/B BACK-TO-BACK
BB BAMBOO
BD BOARD
BDRY BOUNDARY
BEJ BUILDING EXPANSION JOINT
BIA BRICK INSTITUTE of AMERICA
BITUM BITUMINOUS
BKT BRACKET
BLDG BUILDING
BLKG BLOCKING
BLT BORROWED LIGHT
BLVD BOULEVARD
BM BEAM or BENCH MARK
BNG BEARING
BO BY OWNER
BOF BY OWNER, FUTURE
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BUILDING PAPER
BR BEDROOM
BRG BEARNING
BRS BULLET-RESISTANT STEEL
BSMT BASEMENT
BUR BUILT-UP ROOFING
C
C CHANNEL or CELSIUS
CAB CABINET
CATV COMMUNITY ANTENNA (cable) TELEVISION
CB CARRIAGE BOLT, CATCH BASIN, CEMENT BASE,CERAMIC BASE or CORNER BEAD
CBB CEMENTITIOUS BACKER BOARD
CCD CONTRACT CHANGE DIRECTIVE
CCJ CONSTRUCTION JOINT (COLD JOINT)
CCTV CLOSED CIRCUIT TELEVISION
CCW COUNTER-CLOCKWISE
Electrical Engineer:
17542 West 59th Avenue, Suite AGolden, Colorado 80403V: 303.278.7297F: [email protected]
Ackerman Engineering, Inc.
MARK DESCRIPTION DATE
8055
8050
8045
8040
8035
80308020
8015
8010
8075
8080
8085
8085
8080
8075
8075
8070
8070
8065
8060
8055
8055
8065
8060
8055
8075
8060
8060
8055
8055
8050
8045
8040
8035
8040
8035
8050
8045
8040
8035
8030
8025
8020
8025
8030
8015
ELK CREEK ELEMENTARY SCHOOL
EXISTING WELLHOUSE
PROPOSED WWTP BUILDING
ASPHALT PARKING LOT
BASKETBALL
GRAVEL LOT
PLAYGROUND
BASKETBALL
PLAYGROUND
PLAYGROUND
SO
UT
H U
S H
IGH
WA
Y 2
85 F
RO
NT
AG
E R
OA
D
Date
Drawn By
Checked By:
Project Number
Sheet Name
Copyright:
ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE
DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF
MOA ARCHITECTURE
Site
No:
130
00
PH
AS
E O
NE
1/12
/201
5 10
:04:
52 A
M
AS-101
ARCHITECTURALSITE PLAN
EL
K C
RE
EK
EL
EM
EN
TA
RY
SC
HO
OL
RE
NO
VA
TIO
NS
Author
01.13.15
14136.00
1330
4 S
outh
US
Hig
hway
285
, Pin
e, C
olor
ado,
800
04
DESIGN DEVELOPMENT SUBMITTAL - PHASE
ONE
Checker
SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION
GENERAL SHEET NOTES
1 THIS ARCHITECTURAL SITE PLAN FOR REFERENCE ONLY. REFER TO CIVIL DRAWINGS FORGRADES, UTILITIES, DIMENSIONS AND DETAILS.
2
NORTH
NUMBERING IS GROUPED BY TYPE / PHASE OF WORKSHEET OF NON-ARCHITECTURAL ITEMSOR INFORMATIONAL / INSTRUCTIONAL NOTATION.SOME NUMBERS MAY BE SKIPPED ON ANY GIVEN DRAWING SHEET.
SHEET KEYNOTES
AS1
1" = 50'-0"
ARCHITECTURAL SITE PLAN1
MARK DESCRIPTION DATE
100K Classroom
104Classroom
103Classroom
105Classroom
106Classroom
107Classroom
102Classroom
108Classroom
121Planning
101K Classroom
105Planning
305Art
193Conf
191Workroom
189Recept
190Recept
188Office
189Principal
195Clinic
185Office
306Music
307Student Dining
309Gym
197XSto
169Sto
172Sto
174Sto
175Sto
177Kitchen/Serving
176Kitchen/Serving
166Elec
167PE Sto
199XSto
198XSto
203Classroom
202Classroom
204Classroom
205Classroom
206Classroom
200Resource
201Spec Ed
153Planning
300Computer
132AV Sto
133Process
134Periodicals
141Bldg Engr
137Lounge
135Processing
301Library
128Resource
N24Prof Library
Elev
N21Office
N22Sto
dndnup
dn
dn
Open to Below
510Classroom
511Classroom
512Classroom
513Classroom
514Classroom
515Classroom
N19Planning
N20Sto
N04Sto
N23TeleEquip
N05ElevEquip
Elev
N06Sto
up
up
Date
Drawn By
Checked By:
Project Number
Sheet Name
Copyright:
ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE
DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF
MOA ARCHITECTURE
Site
No:
130
00
PH
AS
E O
NE
1/12
/201
5 10
:04:
51 A
M
A-100
ELK CREEK ESMAIN AND LOWER
LEVEL PLAN
EL
K C
RE
EK
EL
EM
EN
TA
RY
SC
HO
OL
RE
NO
VA
TIO
NS
CC
01.13.15
14136.00
1330
4 S
outh
US
Hig
hway
285
, Pin
e, C
olor
ado,
800
04
DESIGN DEVELOPMENT SUBMITTAL - PHASE
ONE
KS
SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION
GENERAL SHEET NOTES1 DRAWINGS ARE SCHEMATIC REPRESENTATION ONLY. CONTRACTOR RESPONSIBLE
FOR VERIFYING ALL EXSITING CONDITIONS AND TO FIELD MEASURE ALL DIMENSIONS.THIS 'DRAWING' IS A DOCUMENT PREPARED FROM AND BASED UPON INFORMATIONPROVIDED BY OTHERS. MOA ARCHITECTURE HAS NOT VERIFIED AND CANNOTWARRANT THE ACCURACY OF THIS INFORMATION. USERS ARE CAUTIONED TO VERIFYINFORMATION CONTAINED HEREIN PRIOR TO RELIANCE UPON IT.
2 THIS PROJECT DOES NOT CHANGE STRUCTURAL SYSTEMS, OCCUPANCYCLASSIFICATIONS, LIFE SAFETY OR TYPES OF CONSTRUCTION.
3 CONTRACTOR RESPONSIBLE FOR PROTECTING EXISTING FINISHES IN ALL AREAS OFCONSTRUCTION.
4 CONTRACTOR TO NOTIFY OWNER / ARCHITECT OF ANY EQUIPMENT ORUNDOCUMENTED ITEMS ENCOUNTERED DURING CONSTRUCTION.
5 CONTRACTOR RESPONSIBLE FOR PROVIDING ALL LABOR, EQUIPMENT AND SERVICESTO PROPERLY EXECUTE THE DEMOLITION AND REMOVAL WORK INDICATED ON THESECONSTRUCTION DOCUMENTS.
6 ALL DEMOLITION WORK SHALL BE PERFORMED WITH MINIMUM DAMAGE TO THEEXISTING WORK TO REMAIN. IT SHALL BE RECOGNIZED THAT THE UTMOST CARE BETAKEN WHILE PERFORMING THE DEMOLITION WORK. PROVIDE BARACADES ASREQUIRED TO PROTECT THE PUBLIC.
7 PROVISIONS SHALL BE MADE TO ALLEVIATE THE SPREAD OF DEBRIS, DIRT, AND DUST.THE PROPOERTY SHALL BE KEPT CLEAN AS POSSIBLE AT ALL TIMES. ANY ASBESTOSREMOVAL SHALL BE DONE PRIOR TO ANY DEMOLITION WORK. THIS WORK SHALL BEDONE BY A LICENSED ABATEMENT COMPANY.
8 ALL DEBRIS AND MATERIALS FROM THE BUILDING SHALL BE DISPOSED OF OFF SITE INA LEGAL MANOR. NO RECLAIMED LUMBER OR MATERIALS SHALL BE REUSED EXCEPTAS SPECIFICALLY APPROVED BY ARCHITECT.
9 WHERE DEMOLITION AND CUTTING WORK HAS OCCURED OR WHERE EXISTINGSURFACES, MATERIALS OR OTHER ITEMS HAVE BEEN DAMEAGED OR DISTURBED ASA RESULT OF THIS CONTRACT, THE SAID SURFACES AND AREAS SHALL BECAREFULLY CLOSED-UP, PATCHED AND FINISHED AND OR RESTORED AS REQUIREDTO BE CONTIGUOUS TO EXISTING SURROUNDING SURFACES.
10 DO NOT REMOVE ANY STRUCTURAL COLUMNS, WALLS OR SUPPORTS. CAREFULLYREMOVE INTERIOR PARTIONS ONLY. IF THERE IS A CONCERN WHETHER AN INTERIORWALL IS 'BEARING', CONTACT ARCHITECT IMMEDIATELY TO SCHEDULE AVERIFICATION TIME.
11 WHERE ELECTRCIAL NEEDS TO BE ABANDONED, REMOVE WIRE FROM OUTLEY ALLTHE WAY BACK TO THE ELECTRICAL PANEL / SOURCE. ALL WORK SHALL BEPERFORMED BY LICENSED ELECTRICIAN.
12 ABBREVIATIONS: REFERENCED FROM THE CONSTRUCTION SPECIFICATIONSINSTITUTES UNIFORM DRAWING SYSTEM TERMS AND ABBREVIATIONS MODULE.REFER TO SHEET INDEX G-001.
13 DIMENSION TICK MARKS ARE SHON AS SOLID DOT MARKS FOR GRIDS, CL MARKS FOROBJECT CENTERLINES, AND DIAGONAL TICK MARKS TO FACE OF OBJECTS.
SHEET SPECIFIC IDENTIFICATION OF ITEMS DIRECTLY REFERENCED TO CORRESPONDINGARCHITECTURAL SPECIFICATION SECTIONS IN THE PROJECT MANUAL. THE DECIMAL ANDSUFFIX NUMBERS / LETTERS ARE NOT IDENTIFIED IN SPECIFICATIONS.
REFERENCE KEYNOTES
NUMBERING IS GROUPED BY TYPE / PHASE OF WORKSHEET OF NON-ARCHITECTURALITEMS OR INFORMATIONAL / INSTRUCTIONAL NOTATION.SOME NUMBERS MAY BE SKIPPED ON ANY GIVEN DRAWING SHEET.
SHEET KEYNOTES
101 ...
1/16" = 1'-0"
ELK CREEK ELEMENTARY SCHOOL - MAIN LEVEL PLAN1
1/16" = 1'-0"
ELK CREEK ELEMENTARY SCHOOL - LOWER LEVEL PLAN2
NORTHNORTH
MARK DESCRIPTION DATE
HWP-1 HWP-2
B-1
B-3
GF-1
ET-1
LVR-7
B-2
M001
Mech
M003
Mech
dn
121
10' -
0"
10' - 0"
122
122
120
Date
Drawn By
Checked By:
Project Number
Sheet Name
Copyright:
ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE
DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF
MOA ARCHITECTURE
Site
No:
130
00
PH
AS
E O
NE
1/12
/201
5 10
:04:
51 A
M
A-110
ELK CREEK ESROOF AND
MECHANICALMEZZANINE PLAN
EL
K C
RE
EK
EL
EM
EN
TA
RY
SC
HO
OL
RE
NO
VA
TIO
NS
CC
01.13.15
14136.00
1330
4 S
outh
US
Hig
hway
285
, Pin
e, C
olor
ado,
800
04
DESIGN DEVELOPMENT SUBMITTAL - PHASE
ONE
KS
SHEET SPECIFIC IDENTIFICATION OF ITEMS DIRECTLY REFERENCED TO CORRESPONDINGARCHITECTURAL SPECIFICATION SECTIONS IN THE PROJECT MANUAL. THE DECIMAL ANDSUFFIX NUMBERS / LETTERS ARE NOT IDENTIFIED IN SPECIFICATIONS.
REFERENCE KEYNOTES
NUMBERING IS GROUPED BY TYPE / PHASE OF WORKSHEET OF NON-ARCHITECTURAL ITEMSOR INFORMATIONAL / INSTRUCTIONAL NOTATION.SOME NUMBERS MAY BE SKIPPED ON ANY GIVEN DRAWING SHEET.
SHEET KEYNOTES
120 EXTEND 4" THICK CONCRETE EQUIPMENT PAD ON SLAB VERIFY SIZE WITH MFG.,LEVEL. DOWEL INTO EXISTING PAD WITH #4 X 16" O.C., EMBED AND EPOXY WITHHILTI HY 200 ADHESIVE.
121 PROVIDE 07 7200.07 SAVETY RAILING SYSTEM.
122 REMOVE EXISTING COUNTER FLASHING ALL AROUND RTU ROOF CURB, PROVIDE 076200.20 PREFINISHED REGLET AND COUNTERFLASHING DEVICE.
1/16" = 1'-0"
ELK CREEK ELEMENTARY SCHOOL - ROOF PLAN1
NORTH
1/8" = 1'-0"
ELK CREEK ELEMENTARY SCHOOL - MECHANICAL MEZZANINE PLAN2
NORTH
SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION
GENERAL SHEET NOTES1 DRAWINGS ARE SCHEMATIC REPRESENTATION ONLY. CONTRACTOR RESPONSIBLE
FOR VERIFYING ALL EXSITING CONDITIONS AND TO FIELD MEASURE ALL DIMENSIONS.THIS 'DRAWING' IS A DOCUMENT PREPARED FROM AND BASED UPON INFORMATIONPROVIDED BY OTHERS. MOA ARCHITECTURE HAS NOT VERIFIED AND CANNOTWARRANT THE ACCURACY OF THIS INFORMATION. USERS ARE CAUTIONED TO VERIFYINFORMATION CONTAINED HEREIN PRIOR TO RELIANCE UPON IT.
2 THIS PROJECT DOES NOT CHANGE STRUCTURAL SYSTEMS, OCCUPANCYCLASSIFICATIONS, LIFE SAFETY OR TYPES OF CONSTRUCTION.
3 CONTRACTOR RESPONSIBLE FOR PROTECTING EXISTING FINISHES IN ALL AREAS OFCONSTRUCTION.
4 CONTRACTOR TO NOTIFY OWNER / ARCHITECT OF ANY EQUIPMENT ORUNDOCUMENTED ITEMS ENCOUNTERED DURING CONSTRUCTION.
5 CONTRACTOR RESPONSIBLE FOR PROVIDING ALL LABOR, EQUIPMENT AND SERVICESTO PROPERLY EXECUTE THE DEMOLITION AND REMOVAL WORK INDICATED ON THESECONSTRUCTION DOCUMENTS.
6 ALL DEMOLITION WORK SHALL BE PERFORMED WITH MINIMUM DAMAGE TO THEEXISTING WORK TO REMAIN. IT SHALL BE RECOGNIZED THAT THE UTMOST CARE BETAKEN WHILE PERFORMING THE DEMOLITION WORK. PROVIDE BARACADES ASREQUIRED TO PROTECT THE PUBLIC.
7 PROVISIONS SHALL BE MADE TO ALLEVIATE THE SPREAD OF DEBRIS, DIRT, AND DUST.THE PROPOERTY SHALL BE KEPT CLEAN AS POSSIBLE AT ALL TIMES. ANY ASBESTOSREMOVAL SHALL BE DONE PRIOR TO ANY DEMOLITION WORK. THIS WORK SHALL BEDONE BY A LICENSED ABATEMENT COMPANY.
8 ALL DEBRIS AND MATERIALS FROM THE BUILDING SHALL BE DISPOSED OF OFF SITE INA LEGAL MANOR. NO RECLAIMED LUMBER OR MATERIALS SHALL BE REUSED EXCEPTAS SPECIFICALLY APPROVED BY ARCHITECT.
9 WHERE DEMOLITION AND CUTTING WORK HAS OCCURED OR WHERE EXISTINGSURFACES, MATERIALS OR OTHER ITEMS HAVE BEEN DAMEAGED OR DISTURBED ASA RESULT OF THIS CONTRACT, THE SAID SURFACES AND AREAS SHALL BECAREFULLY CLOSED-UP, PATCHED AND FINISHED AND OR RESTORED AS REQUIREDTO BE CONTIGUOUS TO EXISTING SURROUNDING SURFACES.
10 DO NOT REMOVE ANY STRUCTURAL COLUMNS, WALLS OR SUPPORTS. CAREFULLYREMOVE INTERIOR PARTIONS ONLY. IF THERE IS A CONCERN WHETHER AN INTERIORWALL IS 'BEARING', CONTACT ARCHITECT IMMEDIATELY TO SCHEDULE AVERIFICATION TIME.
11 WHERE ELECTRCIAL NEEDS TO BE ABANDONED, REMOVE WIRE FROM OUTLEY ALLTHE WAY BACK TO THE ELECTRICAL PANEL / SOURCE. ALL WORK SHALL BEPERFORMED BY LICENSED ELECTRICIAN.
12 ABBREVIATIONS: REFERENCED FROM THE CONSTRUCTION SPECIFICATIONSINSTITUTES UNIFORM DRAWING SYSTEM TERMS AND ABBREVIATIONS MODULE.REFER TO SHEET INDEX G-001.
13 DIMENSION TICK MARKS ARE SHON AS SOLID DOT MARKS FOR GRIDS, CL MARKS FOROBJECT CENTERLINES, AND DIAGONAL TICK MARKS TO FACE OF OBJECTS.
MARK DESCRIPTION DATE
FL
PH
AS
E O
NE
01.13.15
PH
AS
E O
NE
01.13.15
PH
AS
E O
NE
01.13.15
PH
AS
E O
NE
01.13.15
PH
AS
E O
NE
01.13.15
PH
AS
E O
NE
01.13.15
PH
AS
E O
NE
01.13.15
PH
AS
E O
NE
01.13.15
PH
AS
E O
NE
01.13.15
PH
AS
E O
NE
01.13.15