ocps clay springs es submittal transmittal...page 1 of 1 corporate office: 130 candace drive,...

28
SUBMITTAL NUMBER: 260519-01.00 OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL SUBMITTAL DETAILS: REVIEWERS: SUBJECT: BUILDING WIRE & CABLE DATE RECIEVED: Oct 09, 2014 DISCIPLINE: Electrical PRIMARY: TAD RIVENBARK [email protected] KEVIN KING [email protected] MATERN ENGINEERING PHN: (407) 740-5020 FAX: (407) 740-0365 MATERN ENGINEERING PHN: (407) 740-5020 FAX: (407) 740-0365 SECONDARY: PRIORITY STATUS: 2-STANDARD REVIEWER DUE DATE: 10/21/2014 SPECIFICATION REF: 26 05 19 DWG REF. NONE DWG TITLE: NO OF ITEMS: ITEM DESCRIPTI REVIEW STATUS: COMMENTS: CONTRACTOR/CM: : WILLIAMS COMPANY : BRAD KUBIN 2301 SILVER STAR RD. ORLANDO, FL, 32809 (407) 295-2530 FAX:(407) 297-0459 PLEASE SEE A/E COMMENTS. FURNISH AS MARKED RETURNED ITEMS: DATE RETURNED TO CM: 10/13/2014 BUILDING REFERENCE: 1 Product Literature(s) PAGE 1 OF 1 RHODES + BRITO ARCHITECTS INC. : 605 E. ROBINSON STREET, SUITE 750 : ORLANDO, FL. : 32801 : 407.648.7288 : FAX.648.7289 cc: OWNER : CALVIN WOOLFOLK 6501 MAGIC WAY, BLDG. 200 ORLANDO, FL, 32809 (407) 317-3700 FAX:(407) 317-3768 R+B FILE: : 13017-0001.X6

Upload: others

Post on 19-Jan-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

SUBMITTAL NUMBER: 260519-01.00

OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL

SUBMITTAL DETAILS:

REVIEWERS:

SUBJECT: BUILDING WIRE & CABLE

DATE RECIEVED: Oct 09, 2014

DISCIPLINE: Electrical

PRIMARY: TAD RIVENBARK

[email protected]

KEVIN KING

[email protected]

MATERN ENGINEERING

PHN: (407) 740-5020

FAX: (407) 740-0365

MATERN ENGINEERING

PHN: (407) 740-5020

FAX: (407) 740-0365

SECONDARY:

PRIORITY STATUS: 2-STANDARD

REVIEWER DUE DATE: 10/21/2014

SPECIFICATION REF: 26 05 19

DWG REF. NONE

DWG TITLE:

NO OF ITEMS: ITEM DESCRIPTI

REVIEW STATUS:

COMMENTS:

CONTRACTOR/CM:

: WILLIAMS COMPANY: BRAD KUBIN 2301 SILVER STAR RD. ORLANDO, FL, 32809 (407) 295-2530 FAX:(407) 297-0459

PLEASE SEE A/E COMMENTS.

FURNISH AS MARKED

RETURNED ITEMS:

DATE RETURNED TO CM: 10/13/2014

BUILDING REFERENCE:

1 Product Literature(s)

PAGE 1 OF 1RHODES + BRITO ARCHITECTS INC. : 605 E. ROBINSON STREET, SUITE 750 : ORLANDO, FL. : 32801 : 407.648.7288 : FAX.648.7289

cc:

OWNER : CALVIN WOOLFOLK 6501 MAGIC WAY, BLDG. 200 ORLANDO, FL, 32809 (407) 317-3700

FAX:(407) 317-3768

R+B FILE: : 13017-0001.X6

michele
Rick
101374
Received
Page 2: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

Page 1 of 1

Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville | Tampa | www.matern.net

SHOP DRAWING COMMENTS

Date: October 10, 2014 By: Tad Rivenbark Submittal: 26 05 19 – Building Wire & Cable

Project: OCPS – Clay Springs E.S. Proj. No: 2013-224

THE FOLLOWING COMMENTS SHALL BE CONSIDERED AN INTEGRAL PART OF THE SHOP DRAWING AND/OR PRODUCT DATA SUBMITTAL.

26 05 19: Make Corrections Noted.

Use solid conductor for feeders and branch circuits 10 AWG and smaller (except for control circuits). Use conductor not smaller than 12 AWG for power and lighting circuits. Push in wire connectors are not specified for use on this project and shall not be used.

END OF SHOP DRAWING COMMENTS

ACTION CODE KEY

A No exceptions taken. B Make corrections noted. C Revise and Resubmit. D Submit Specified Item. E Rejected. N Review not required.

Page 3: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

SUBMITTAL NUMBER: 26051901.00

OCPS CLAY SPRINGS ES SUBMITTAL ASSIGNMENT MEMO

SUBMITTAL DETAILS: REVIEWERS:

SUBJECT: BUILDING WIRE & CABLE

DATE RFI RECIEVED: Oct 09, 2014

DISCIPLINE: Electrical

PRIMARY: TAD RIVENBARK

[email protected]

KEVIN KING

[email protected]

MATERN ENGINEERING

PHN: (407) 740-5020FAX: (407) 740-0365

MATERN ENGINEERING

PHN: (407) 740-5020

FAX: (407) 740-0365

SECONDARY:

PRIORITY STATUS: 2-STANDARD

REVIEWER DUE DATE: 10/21/2014

SPECIFICATION REF: 26 05 19

DWG REF. NONE

DWG TITLE:

REVIEW STATUS:

THIS SUBMITTAL IS ISSUED TO YOU FOR YOUR REVIEW. PLEASE RESPOND AND RETURN...WITH THIS COMPLETED SAM TRANSMITTAL...TO MICHELE BUDAY-URDANETA NO LATER THAN: 10/21/2014. PLEASE COMPLETE REVIEW STATUS AT RIGHT

SUBMITTAL CONTENTS:

NO OF ITEMS: ITEM DESCRIPTION

(please print)THIS SUBMITTAL WAS REVIEWED BY :

RE-SUBMIT WITH ITEMS

NOT REVIEWED

REJECTED

REVISE AND RESUBMIT

FURNISHED AS MARKED

REVIEWED

COMMENTS:

1 PRODUCT LITERATURE(S)

cc:

OWNER : CALVIN WOOLFOLK

6501 MAGIC WAY, BLDG. 200

ORLANDO, FL, 32809

R+B FILE: : 13017-0001.X6CONTR/CM: : WILLIAMS COMPANY

: BRAD KUBIN

2301 SILVER STAR RD.

Page 4: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

Submittal Cover.doc

ABC ACCREDITED QUALITY CONTRACTOR EC-0000981

430 West Drive Altamonte Springs, Florida 32714 EC-0000981 Phone: (407) 788-3500

CLAY SPRINGS ELEMENTARY SCHOOL

TCE JOB #100707

OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809

GENERAL CONTRACTOR: Williams Company 2301 Silver Star Road Orlando, FL 32804

ARCHITECT: Rhodes + Brito Architects 605 E. Robinson Street, Suite 750 Orlando, FL 32801

ENGINEER: Matern Professional Engineering, Inc. 130 Candace Drive Maitland, FL 32751

SUBCONTRACTOR: Tri-City Electrical Contractors, Inc. 430 West Drive Altamonte Springs, FL 32714

Specification Section: 26 05 19 Building Wire & Cable

10/2/14

katrinae
WCBD - Trent
katrinae
Accepted
trivenbark
Shop Drawings
Page 5: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

PRODUCT CATALOG

Page 6: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

1 - 8 0 0 - 9 6 2 - 9 4 7 3

1

1410 MILLWOOD ROAD • MCKINNEY, TX. 75069 • 972-542-4744 FAX

S O F T D R A W N B A R E C O P P E R C O N D U C T O R S

Features:Highest conductivity per unit area of all commoncommercial metals. Excellent corrosion resistance.Flexible, easily worked and formed into place.Packaged on non-returnable spools for easytransportation to job sites and to provide adequatefootage for mass installations. Good fatigue resistance;not subject to breaks due to nicks or cuts whenterminating. Totally recyclable with high scrap value.

ENGINEERING SPECIFICATIONS:

Standards: ASTM B-3 for soft-drawn temper solid copperwire

ASTM B-8 for soft-drawn temper concentric laystranded copper wire

ASTM B-787 for 19-wire combination unilaystranded wire

Construction: Soft-drawn Solid or Stranded Annealed Bare Copper.

Application: Copper Conductors are used in overhead electricaltransmission and distribution systems, for groundingelectrical Systems, and where high conductivity andflexibility are required for equipment and circuitgrounding.

SizeAWG

or KcmilNumber

of Strands (inches) (mm) (cmils)Rated

Strength (lbs)DC Resistance

Ohms/1000 ft. @ 20C

ApproxNet WeightLbs./M.ft.

14 Solid .0641 1.628 4,110 124 2.5200 12.412 Solid .0808 2.052 6,530 197 1.5850 19.810 Solid .1019 2.588 10,380 314 .9988 31.48 Solid .1285 3.264 16,510 479 .6280 506 Solid .1620 4.115 26,240 762 .3951 79.54 Solid .2043 5.189 41,740 1214 .2485 126.42 Solid .2576 6.543 66,360 1930 .1563 200.9

Outside Diameter Soft-Drawn (Annealed)

SizeAWG

or KcmilNumber

of Strands (inches) (mm) (cmils)Rated

Strength (lbs)DC Resistance

Ohms/1000 ft. @ 20c

ApproxNet WeightLbs./M.ft.

8 7 .1460 3.61 16,510 498 .6408 516 7 .1840 4.52 26,240 795 .4030 814 7 .2320 5.72 41,740 1320 .2540 1293 7 .2600 6.40 52,620 1670 .2010 1622 7 .2830 7.19 66,360 2110 .1578 2051 7 .3220 8.18 83,690 2552 .1255 258

1/0 19 .3620 9.19 105,600 3221 .1002 3252/0 19 .4050 10.3 133,100 4060 .0795 4103/0 19 .4560 11.6 167,800 5118 .0631 5184/0 19 .5120 13.0 211,600 6459 .0499 653250 37 .5420 13.77 250,000 7942 .0424 772300 37 .5940 15.09 300,000 9164 .0353 926350 37 .6410 16.28 350,000 10685 .0302 1081400 37 .6850 17.40 400,000 13435 .0264 1235500 37 .7660 19.46 500,000 15242 .0212 1544600 61 .8930 22.00 600,000 18300 .0176 1853750 61 .9980 24.60 750,000 22894 .0141 23161000 61 1.152 28.40 1,000,000 30500 .0106 3088

Outside Diameter Soft-Drawn (Annealed)

The above data is approximate and subject to normal manufacturing tolerances.Note: 1/0 - 4/0 Bare copper available in 7/w construction.

Page 7: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

1 - 8 0 0 - 9 6 2 - 9 4 7 3

4

1410 MILLWOOD ROAD • MCKINNEY, TX. 75069 • 972-542-4744 FAX

CopperConductor

PVCInsulation

NylonJacket

T H H N / M T W / T H W N - 2 C O P P E R C O N D U C T O R

Appl i cat ion:Encore Type THHN-THWN-2 building wire is intended forgeneral purpose applications as defined by the NationalElectrical Code (NEC). Suitable for new construction or rewiringfor 600-volt applications. When used as type THHN or THWN-2, conductor is suitable for use in wet or dry locations at temp-eratures not to exceed 90°C, or not to exceed 75°C in oil orcoolants. When used as type MTW, conductor is suitable for usein dry locations at 90°C, or not to exceed 60°C in wet locationsor where exposed to oils or coolants. When used as type AWMtemperatures should not exceed 105°C in dry locations.

LISTED SOLID E-123774STRANDED E-156879

ENGINEERING SPECIFICATIONS:

Standards: Underwriters Laboratories Standard UL-83, UL-1063, UL-758.AWM Spec 1316, 1317, 1318, 1319, 1320, 1321 ASTM StrandingClass B-3, B-8, B-787Federal Specification A-A-59544Canadian Standards Association C22.2 No. 75NEMA WC5/ICEA S-61-402

Packaging: 14 and 12 AWG — 4 x 500' spools, 2,000' per carton or2,500' reels. 10 AWG — 2 x 500' spools, 1,000' percarton or 2,500' reel. 8 AWG — 500' carton, 1,000’,2,500’, or 5,000' reel. 6 AWG — 500', 1,000', 2,500',or 5,000' reel. 4 AWG through 1000 KCMIL — 500',1,000', or longer lengths on reels.

Construction: Conductors: Solid conductors, uncoated copper, perASTM B3. Stranded conductors uncoated copper perASTM B3, ASTM B787and ASTM B8.Conductors Insulation:Color-coded, Polyvinyl chloride (PVC), heat-and Moisture-resistant, flame-retardantcompound per UL-83 and UL-1063.Jacket: A tough, polyamide, outer-nylon coveringper UL-83 and UL-1063.Features: Slick, outer-nylon jacket for easy pulling.VW-1 rated 14 AWG - 1 AWG, 1/0AWG and larger is rated for CT use. 6AWG and larger is rated for SunlightResistance in all colors. All sizes are rated“Gasoline and Oil Resistant II.”Print Legend: Conductor Sizes 14 AWG through 10 AWG Solid:E123774 (SIZE) AWG TYPE THHN ORTHWN-2 GASOLINE AND OIL RESISTANTII VW-1 600V (UL) OR AWM OR C-(UL)TYPE T90 NYLON OR TWN 75 FT1Conductor Sizes 14 AWG through 1 AWG Stranded:E156879 (SIZE) AWG TYPE MTW ORTHHN OR THWN-2 GASOLINE AND OILRESISTANT II VW-1 600V (UL) OR AWMOR C-(UL) TYPE T90 NYLON OR TWN 75FT1 DATE/TIME/OPERConductor Sizes 1/0 AWG - 500 KCMIL Stranded:E156879 (SIZE) AWG OR KCMIL TYPEMTW OR THHN OR THWN-2 GASOLINEAND OIL RESISTANT II SUNLIGHTRESISTANT FOR CT USE 600V (UL) OR C-(UL) TYPE T90 NYLON OR TWN 75 FT1DATE/TIME/OPERConductor Sizes 500 KCMIL - 1000 KCMIL Stranded:E156879 (SIZE) KCMIL TYPE MTW ORTHHN OR THWN-2 GASOLINE AND OILRESISTANT II SUNLIGHT RESISTANT FORCT USE 600V (UL)DATE/TIME/OPER

Ampacity shown above is per the 2002 National Electrical Code. The above data is approximate and subject to normal manufacturing tolerances.

SizeAWG

or Kcmil Number

of Strands

Conductor Size

(mm2)

InsulationThickness

PVC Nylon (Inches) ((mm) 60C 75C 90C

ApproxNet WeightLbs./M.ft.

14 SOL 2.08 .015 .004 .101 2.57 15 15 15 15

12 SOL 3.31 .015 .004 .120 3.05 20 20 20 23

10 SOL 5.26 .020 .004 .149 3.78 30 30 30 3714 19 2.08 .015 .004 .109 2.77 15 15 15 17

12 19 3.31 .015 .004 .127 3.23 20 20 20 24

10 19 5.26 .020 .004 .160 4.07 30 30 30 388 19 8.37 .030 .005 .212 5.39 40 50 55 63

6 19 13.3 .030 .005 .248 6.30 55 65 75 95

4 19 21.2 .040 .006 .317 8.06 70 85 95 153

3 19 26.7 .040 .006 .344 8.74 85 100 110 189

2 19 33.6 .040 .006 .375 9.53 95 115 130 234

1 19 42.4 .050 .007 .435 11.05 110 130 150 2991/0 19 53.5 .050 .007 .474 12.04 125 150 170 372

2/0 19 67.4 .050 .007 .518 13.16 145 175 195 462

3/0 19 85.0 .050 .007 .568 14.43 165 200 225 572

4/0 19 107 .050 .007 .624 15.85 195 230 260 712250 37 127 .060 .008 .678 17.23 215 255 290 851

300 37 152 .060 .008 .730 18.55 240 285 320 1010

350 37 177 .060 .008 .777 19.74 260 310 350 1170

400 37 203 .060 .008 .821 20.86 280 335 380 1330

500 37 253 .060 .008 .902 22.91 320 380 430 1650600 61 304 .070 .009 1.051 26.70 355 420 475 1985

750 61 380 .070 .009 1.156 29.37 400 475 535 2455

1000 61 507 .070 .009 1.310 33.28 455 545 615 3252

Overall OutsideDiameter

AllowableAmpacities

Page 8: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

grounded in service wired to innovate™

STABILOY®

Type XHHW-2 and USE-2/RHH/RHW-2

Page 9: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

Alcan manufactures XHHW-2 and USE-2/RHH/RHW–2 STABILOY®

cables which are intended for use in general purpose wiring in residential,

commercial and industrial construction. In addition, Type

USE-2/RHH/RHW–2 is primarily used as Type USE-2 direct- buried

underground service entrance, but is listed for RHH or RHW-2 for appli-

cations in general purpose lighting and power. As with all STABILOY®

building wire, these products are high quality, dependable and offer

tremendous flexibility. They exceed the requirements of the Underwriters

Laboratories, Inc. standards and are approved for use in accordance with

the recommendations of the National Electrical Code. STABILOY® alloy

conductor is recognized by ASTM.

Product Features Alcan Type XHHW-2 and USE-2/RHH/RHW–2 offer severalexceptional features:

• Lightweight for easier lifting and handling because STABILOYconductors weigh half as much as copper.

• Maximum operating temperature of 90˚C in dry and wet locations which exceeds the requirements for installations ofservice and feeder circuits.

• Sunlight resistant, moisture resistant and flame-retardantinsulation, which enhances the life of the cable by fending offenvironmental elements that can cause deterioration.

• Increased flexibility because both XHHW-2 and USE-2/RHH/RHW-2 are made with STABILOY AA-8030 conductors which require less bending force and have less spring back than copper conductors.

• Cross-linked polyethylene insulation (XLPE) over STABILOYconductors offers higher short-circuit withstand capability thanthe traditional THHN/THWN-2 insulation used on copper conductors.

• NEW! Size 900 kcmil now available as a better choice over 600kcmil copper!

Type XHHW-2 and Type USE-2/RHH/RHW-2

Page 10: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

Description:XHHW-2 is a compact stranded conductor. Mylar tape may be placed between the XLPE insulation and the conductor strands.

Application:Installed in raceways for general-purpose wiring for upto 600V rated service and feeder circuits in residential,commercial, institutional and industrial buildings. Also,used in cable trays (with “CT USE” marking) and mes-senger supported wiring applications.

Marking:Cables will bear the following surface marking: Alcan(Plant of Manufacture) (Size) Compact AL STABILOY®AA-8030 Series XLPE 600 V XHHW-2 SUN-RES (UL)(Year of Manufacture).

Available Options:Contact Alcan Cable for:600V XHHW-2 conductors rated for"CT USE" and other markings.

Type XHHW-2

NOTES:1. Data are approximate and subject to normal manufacturing tolerances.2. Standard lengths are subject to normal manufacturing tolerances of ±10%.3. Two, three or four conductors can be paralleled on a reel.4. The suffix -2 indicates that these wire types can be used at a continuous 90°C operating temperature in wet and dry locations.

NOMINAL DIMENSIONSSize Insulation BARE XHHW-2 Bare XHHW-2 NOMINAL WEIGHTAWG Thickness Conductor Conductor Conductor Conductor (LBS./1000FT.) STANDARD PACKAGE

or kcmil (Mils) Diameter Diameter Area Area STABILOY Total Length Reel(Inches) (Inches) (Sq. Inches) (Sq. Inches)

6 45 .169 .260 .0224 .0530 25 39 1000' NRC 16.154 45 .213 .305 .0356 .0730 39 57 1000' NRC 16.152 45 .268 .360 .0564 .1017 62 84 1000' NRC 21.15

1 55 .299 .415 .0702 .1352 79 108 1000' NRC 21.151/0 55 .336 .450 .0887 .1590 99 132 1000' NRC 21.152/0 55 .376 .490 .1110 .1885 125 161 1000' NRC 21.183/0 55 .423 .540 .1405 .2290 157 198 1000' NRC 24.154/0 55 .475 .590 .1772 .2733 199 244 1000' NRC 24.18

250 65 .520 .655 .2124 .3370 235 292 1000' NRC 27.18300 65 .570 .705 .2552 .3904 282 344 1000' NRC 30.18350 65 .616 .750 .2980 .4418 329 396 1000' NRC 30.24400 65 .659 .795 .3411 .4964 376 448 1000' NRC 32.24500 65 .736 .870 .4254 .5945 469 550 1000' NRC 32.24

600 80 .813 .980 .5191 .7542 563 671 1000' NRC 36.24700 80 .877 1.040 .6041 .8494 657 774 1000' NRC 40.24750 80 .908 1.075 .6475 .9076 704 824 1000' NRC 40.24900 80 .999 1.169 .7838 1.0733 847 983 1000' NRC 42.261000 80 1.060 1.230 .8825 1.1882 939 1079 1000' NRC 48.25

Page 11: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

Allowable Ampacities†

30°C (86°F) Ambient Temperature

Ampacities are based on conductor operating tempera-tures only and do not take voltage drop into consideration.

When the number of current carrying conductors in a raceway or cable exceeds three, the allowable ampacity of each conductor shall be reduced to the following percentages of tabular values:

4 to 6 80%7 to 9 70%10 to 20 50%21 to 30 45%31 to 40 40%

In dwelling units, conductors are permitted to be utilized as 120/240 volt, 3-wire, single-phase serviceentrance conductors and feeder conductors in raceway or cable with or without an equipment grounding con-ductor. The allowable ampacity for Types XHHW-2, RHW-2and RHH aluminum conductors are:

S T A B I L O Y X H H W-2 v s . C o p p e r T H W N & T H H NA m p a c i t i e s a n d C o r r e c t i o n F a c t o r s

NOTES:1.Based on NEC Table 310.16.

† See termination provisions for conductor sizing as given in Underwriters Laboratories Electrical Construction MaterialsDirectory, “Equipment for Use in Ordinary Locations.”

STABILOY Type XHHW-2 and Type USE-2/RHH/RHW-2 con-ductors can be operated at 90°C in dry AND wet locations.This characteristic is advantageous when derating of con-ductor ampacity is required, for example, when there arefour or more current carrying conductors in a raceway orcable in a wet location. In this instance one can begin withthe 90°C ampacity from which to derate.

System design loads falling between values listed in thistable for copper THHN often permit the use of a smallerSTABILOY conductor than would be necessary based onthe maximum ampacity of the copper conductor required.

Example:For a design load of 380 amps, the required 500 kcmil copper THHN conductor would have to be replaced by a 750 kcmil STABILOY conductor (75°C, wet location).However, if the design load was between 336 and 375 amps(still requiring 500 kcmil copper), a 700 kcmil STABILOY conductor would be adequate.

AMPACITIES (AMPS)†

Conductor Size COPPER STABILOY Conductor SizeAWG or kcmil THWN (75°C) THHN, THHN-2 (90°C) XHHW (75°C) XHHW-2 (90°C) AWG or kcmil

6 65 75 50 60 64 85 95 65 75 42 115 130 90 100 21 130 150 100 115 1

1/0 150 170 120 135 1/02/0 175 195 135 150 2/03/0 200 225 155 175 3/04/0 230 260 180 205 4/0250 255 290 205 230 250300 285 320 230 255 300350 310 350 250 280 350400 335 380 270 305 400500 380 430 310 350 500600 420 475 340 385 600700 460 520 375 420 700750 475 535 385 435 750900 520 585 425 480 9001000 545 615 445 500 1000

Size Amps#2AWG 1001 1101/0 1252/0 150

Size Amps350kcmil 300500kcmil 350600 kcmil 400

Size Amps3/0 1754/0 200250kcmil 225300kcmil 250

Page 12: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

S T A B I L O Y A m p a c i t i e s a n d C o r r e c t i o n F a c t o r s

NOT MORE THAN THREE* SINGLE INSULATED CONDUCTORS IN A RACEWAY IN FREE AIR** SINGLE INSULATED CONDUCTOR IN FREE AIR**

75°C (167°F) 90°C (194°F) 75°C (167°F) 90°C (194°F)Size AWG XHHW, XHHW-2, RHH, XHHW, XHHW-2, RHH, Size AWGor kcmil RHH, RHW, USE RHW-2, USE-2 RHH, RHW, USE RHW-2, USE-2 or kcmil

8 40 45 55 60 86 50 60 75 80 64 65 75 100 110 42† 90 100 135 150 2†

1† 100 115 155 175 1†

1/0† 120 135 180 205 1/0†

2/0† 135 150 210 235 2/0†

3/0† 155 175 240 275 3/0†

4/0† 180 205 280 315 4/0†

250 205 230 315 355 250300 230 255 350 395 300350 250 280 395 445 350400 270 305 425 480 400500 310 350 485 545 500600 340 385 540 615 600700 375 420 595 675 700750 385 435 620 700 750900 425 480 700 785 9001000 445 500 750 845 1000

NOTES:

1. Ampacities are based on conductor operating temperatures only and do not take voltage drop into consideration.

2. A neutral conductor which carries only the unbalanced current from other conductors, as in the case of normally balanced cir-cuits of three or more conductors, shall not be counted in determining Ampacity Adjustment Factors. But in a three-wire circuitconsisting of two phase wires and the neutral of a four-wire three-phase Wye-connected system, a common conductor carriesapproximately the same current as the other conductors and shall be counted in determining ampacities.

3. Based on Ambient Air Temperature of 30°C (86°F).

* See 310.15(B)(4)

** See termination provisions for conductor sizing as given in Underwriters Laboratories Electrical Construction MaterialsDirectory, “Equipment for Use in Ordinary Locations.”

† In dwelling units, conductors shall be permitted to be utilized as 120/240 volt, 3-wire, single-phase service entrance conductorsand feeder conductors in raceway or cable with or without an equipment grounding conductor. The allowable ampacity for TypesXHHW-2, RHW-2 and RHH aluminum conductors shall be:

Ampacity Correction Factors

For ambient temperatures other than 30°C (86°F), multiply the

ampacities shown above by the

Ambientappropriate factor shown below.

AmbientTemp.°C 75°C 90°C Temp.°F

21–25 1.05 1.04 70–7726–30 1.00 1.00 79–8631–35 .94 .96 88–9536–40 .88 .91 97–10441–45 .82 .87 106–11346–50 .75 .82 115–12251–55 .67 .76 124–13156–60 .58 .71 133–14061–70 .33 .58 142–15871–80 – .41 160–176

Size Amps#2AWG 1001 1101/0 1252/0 150

Size Amps350kcmil 300500kcmil 350600 kcmil 400

Size Amps3/0 1754/0 200250kcmil 225300kcmil 250

Page 13: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

MAX

IMUM

NUM

BER

OF T

YPE

XHHW

-2 C

OMPA

CT S

TABI

LOYR

ALUM

INUM

ALL

OY C

ONDU

CTOR

S IN

CON

DUIT

TABL

E C7

ATA

BLE

C9A

TABL

E C1

1ACO

NDUC

TOR

LIQU

IDTI

GHT

FLEX

IBLE

MET

ALLI

C CO

NDUI

TRI

GID

PVC

COND

UIT,

Sch

edul

e 80

Type

A R

IGID

PVC

CON

DUIT

SIZE

TRAD

E SI

ZES

IN IN

CHES

TRAD

E SI

ZES

IN IN

CHES

TRAD

E SI

ZES

IN IN

CHES

AWG/

KCM

IL3/

81/

23/

41

1 1/

41

1/2

22

1/2

33

1/2

41/

23/

41

1 1/

41

1/2

22

1/2

33

1/2

45

61/

23/

41

1 1/

41

1/2

22

1/2

33

1/2

46

12

46

1115

2437

5673

951

35

913

2131

4865

8513

419

33

58

1317

2741

6280

103

41

13

48

1117

2641

5369

11

36

915

2235

4761

9814

01

36

912

2030

4558

752

11

13

67

1219

2938

501

12

56

1116

2534

4470

100

12

47

914

2132

4254

10

11

24

69

1422

2837

11

13

58

1219

2533

5375

11

35

710

1624

3140

1/0

01

11

45

812

1924

320

11

34

710

1622

2845

641

12

46

913

2027

342/

00

11

13

47

1016

2027

01

12

36

813

1824

3854

11

13

57

1117

2229

3/0

00

11

23

58

1317

220

11

13

57

1115

1931

441

11

34

69

1418

244/

00

01

11

34

711

1418

00

11

24

69

1216

2637

01

12

35

812

1520

250

00

11

11

35

811

150

01

11

35

710

1321

300

11

12

46

912

1630

00

00

11

13

57

912

00

11

13

46

811

1725

01

11

13

58

1013

350

00

01

11

34

68

110

01

11

23

57

1015

220

01

11

35

79

1240

00

00

11

12

46

710

00

01

11

35

79

1420

00

11

13

46

811

500

00

00

11

13

56

80

00

11

12

45

711

170

01

11

23

57

960

00

00

01

11

24

56

00

01

11

13

46

913

00

01

11

34

57

700

00

00

11

11

34

60

00

01

11

34

58

120

00

11

12

35

675

00

00

01

11

13

45

00

00

11

12

35

711

00

01

11

23

46

900

00

00

01

12

23

40

00

01

11

23

46

80

00

11

12

34

510

000

00

00

11

12

34

00

00

01

11

33

68

00

00

11

12

34

TABL

E C8

ATA

BLE

C10A

TABL

E C1

2ACO

NDUC

TOR

RIGI

D M

ETAL

LIC

COND

UIT

RIGI

D PV

C CO

NDUI

T, S

ched

ule

40

Type

EB,

PVC

CON

DUIT

SI

ZETR

ADE

SIZE

S IN

INCH

ESTR

ADE

SIZE

S IN

INCH

ESTR

ADE

SIZE

S IN

INCH

ESAW

G/KC

MIL

1/2

3/4

11

1/4

1 1/

22

2 1/

23

3 1/

24

56

1/2

3/4

11

1/4

1 1/

22

2 1/

23

3 1/

24

56

23

3 1/

24

56

62

46

1115

2536

5675

9715

222

01

46

1115

2535

5573

9414

921

529

6585

109

167

238

41

35

811

1826

4155

7011

015

91

24

811

1825

4053

6810

815

621

4762

7912

117

22

11

36

813

1929

3950

7911

41

13

58

1318

2838

4977

112

1534

4457

8712

41

11

24

610

1422

2938

6086

11

24

69

1421

2937

5884

1125

3342

6593

1/0

11

14

58

1219

2532

5173

11

13

58

1218

2431

4972

922

2836

5679

2/0

11

13

47

1016

2127

4362

11

13

47

1015

2026

4260

818

2430

4767

3/0

01

12

36

813

1722

3551

01

12

35

812

1722

3450

615

2025

3855

4/0

01

11

35

711

1419

2942

01

11

35

710

1418

2942

512

1621

3246

250

01

11

24

58

1115

2334

00

11

14

58

1114

2333

410

1317

2637

300

00

11

13

57

1013

2029

00

11

13

47

912

1928

48

1114

2231

350

00

11

13

46

911

1825

00

11

13

46

811

1725

37

1012

1928

400

00

11

12

46

810

1623

00

11

12

35

710

1522

37

911

1725

500

00

01

11

35

68

1319

00

01

11

34

68

1318

25

79

1420

600

00

01

11

24

57

1015

00

01

11

24

56

1015

14

67

1116

700

00

01

11

13

46

913

00

01

11

13

45

913

14

56

1014

750

00

01

11

13

45

812

00

01

11

13

45

812

13

56

913

900

00

00

11

22

35

710

00

00

11

12

34

69

13

45

710

1000

00

00

11

12

34

710

00

00

11

12

34

69

13

45

710

DAT

A F

RO

M T

HE

NAT

ION

AL

ELE

CT

RIC

AL

CO

DE

®

ALC

AN

CA

BLE

NE

C is

a r

egis

tere

d tr

adem

ark

of T

he N

atio

nal

Fire

Pro

tect

ion

Ass

ocia

tion

STA

BIL

OY

® is

a r

egis

tere

d tr

adem

ark

of

Alc

an P

rodu

cts

Cor

pora

tion

for

AA

-803

0 A

lum

inum

Allo

y C

ondu

ctor

Mat

eria

l

Page 14: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

ALC

AN

CA

BLE

MAX

IMUM

NUM

BER

OF T

YPE

XHHW

-2 C

OMPA

CT S

TABI

LOYR

ALUM

INUM

ALL

OY C

ONDU

CTOR

S IN

CON

DUIT

TABL

E C1

ATA

BLE

C3A

TABL

E C5

ACO

NDUC

TOR

ELEC

TRIC

AL M

ETAL

LIC

TUBI

NGFL

EXIB

LE M

ETAL

LIC

COND

UIT

LIQU

IDTI

GHT

FLEX

IBLE

NON

MET

ALLI

C CO

NDUI

T (F

NMC-

B)

SIZE

TRAD

E SI

ZES

IN IN

CHES

TRAD

E SI

ZES

IN IN

CHES

TRAD

E SI

ZES

IN IN

CHES

AWG/

KCM

IL1/

23/

41

1 1/

41

1/2

22

1/2

33

1/2

41/

23/

41

1 1/

41

1/2

22

1/2

33

1/2

43/

81/

23/

41

1 1/

41

1/2

26

14

611

1525

4466

8711

12

46

914

2437

5372

951

24

611

1524

41

34

811

1832

4863

811

34

710

1827

3852

691

13

48

1117

21

13

68

1323

3445

581

13

57

1319

2838

491

11

36

712

11

12

46

1017

2634

431

12

35

914

2128

370

11

24

69

1/0

11

13

58

1422

2937

11

13

48

1217

2431

01

11

45

82/

01

11

34

712

1824

311

11

24

710

1520

260

11

13

47

3/0

01

12

36

1015

2025

01

11

35

812

1722

00

11

23

54/

00

11

13

58

1317

210

11

12

47

1014

180

01

11

34

250

01

11

24

710

1317

01

11

14

58

1114

00

11

11

330

00

01

11

36

911

140

01

11

35

79

120

00

11

13

350

00

11

13

58

1013

00

11

13

46

811

00

01

11

340

00

01

11

24

79

110

01

11

24

57

100

00

11

12

500

00

01

11

46

79

00

01

11

34

68

00

00

11

160

00

00

11

13

46

80

00

11

12

35

60

00

01

11

700

00

01

11

24

57

00

00

11

13

46

00

00

11

175

00

00

11

12

35

60

00

01

11

34

50

00

01

11

900

00

00

11

23

45

00

00

11

22

34

00

00

01

110

000

00

01

11

34

50

00

01

11

23

40

00

00

11

TABL

E C2

ATA

BLE

C4A

TABL

E C6

ACO

NDUC

TOR

ELEC

TRIC

AL N

ONM

ETAL

LIC

TUBI

NGIN

TERM

EDIA

TE M

ETAL

LIC

COND

UIT

LIQU

IDTI

GHT

FLEX

IBLE

NON

MET

ALLI

C CO

NDUI

T (F

NMC-

A)

SIZE

TRAD

E SI

ZES

IN IN

CHES

TRAD

E SI

ZES

IN IN

CHES

TRAD

E SI

ZES

IN IN

CHES

AWG/

KCM

IL1/

23/

41

1 1/

41

1/2

21/

23/

41

1 1/

41

1/2

22

1/2

33

1/2

43/

81/

23/

41

1 1/

41

1/2

26

13

610

1424

24

712

1627

3859

8010

31

24

611

1525

41

24

710

171

35

912

2028

4358

741

13

48

1118

21

13

57

121

13

68

1420

3141

531

11

36

813

11

12

45

91

13

56

1015

2331

400

11

24

610

1/0

11

13

58

11

14

59

1320

2634

01

11

35

82/

00

11

34

71

11

34

711

1722

290

11

13

47

3/0

01

12

35

01

13

46

914

1824

00

11

23

64/

00

11

13

40

11

23

57

1115

200

01

11

35

250

00

11

13

01

11

24

69

1216

00

11

12

430

00

01

11

30

01

11

35

810

130

00

11

13

350

00

11

13

00

11

13

47

912

00

01

11

340

00

01

11

20

01

11

34

68

110

00

11

12

500

00

01

11

00

01

12

35

79

00

00

11

160

00

00

11

10

00

11

12

45

70

00

01

11

700

00

01

11

00

01

11

23

56

00

00

11

175

00

00

11

10

00

11

11

34

60

00

01

11

900

00

00

11

00

00

11

23

45

00

00

01

110

000

00

01

10

00

01

11

23

40

00

00

11

DAT

A F

RO

M T

HE

NAT

ION

AL

ELE

CT

RIC

AL

CO

DE

®

NE

C is

a r

egis

tere

d tr

adem

ark

of T

he N

atio

nal F

irePr

otec

tion

Ass

ocia

tion

STA

BIL

OY

® is

a r

egis

tere

d tr

adem

ark

of

Alc

an P

rodu

cts

Cor

pora

tion

for

AA

-803

0 A

lum

inum

Allo

y C

ondu

ctor

Mat

eria

l

Page 15: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

Wing-Nut® Wire Connectors

� Three color-coded models cover a full range of wire sizes from 18 through 6 AWG

� Specially designed contoured wings provide a secure grip for extra leverage on maximum wire combinations

� Live-action spring expands to accept wire shape and size with no pre-twisting required

� Square-wire spring threads directly onto conductors for fast, secure connections

� Deep skirt helps protect against flash-over and turned-backstrands for maximum dielectric protection

� Easily removed for repeat usage on same size or larger wirecombinations

� Tough, UL 94V-2 flame-retardant shell rated at 105°C (221°F)

� UL Listed to 486C and CSA Certified to C22.2 #188; complywith Federal Specification W-S-610E

� Classified in accordance with IEC Publications 998-2 and 998-2-4

Tough, durablethermoplastic shell

Live-action,square-wire spring

Deep skirt, wide throat

Comfortablecontoured wings

Wire

Co

nn

ecto

rs

www.idealindustries.com 1-800-435-0705 for Customer ServiceA-4

ULRLIST

ED

- WIRE CON

N

C USEN 60-998-2-4

Wire Combination Wire CombinationModel Color Range Range (mm) Quantity Cat. No.

Box of 100 30-451600V* 600V* Jar of 225 30-451J

451® Yellow 18 thru 10 AWG ,75mm2 to 6,0mm2 Jar of 500 30-651JMin. 2 #18 Min. 2-,75mm2 Carton of 1,000 30-551Max. 3 #12 Max. 3-4,0mm2 Keg of 5,000 (10 bags, 500 ea.) 30-651

Barrel of 35,000 30-851Box of 100 30-452

600V* 600V* Jar of 300 30-452J

452® Red 18 thru 8 AWG ,75mm2 to 10,0mm2 Jar of 500 30-652JMin. 2 #18 Min. 2-,75mm2 Carton of 1,000 30-552Max. 4 #10 Max. 4-6,0mm2 Keg of 5,000 (10 bags, 500 ea.) 30-652

Barrel of 25,000 30-852600V* 600V*

454® Blue 14 thru 6 AWG 2,5mm2 to 16,0mm2 Box of 50 30-454

Min. 3 #12 Min. 3-4,0mm2

Keg of 2,500 (25 bags, 100 ea.) 30-654Max. 1 #6 & 2 #8 Max. 2-16,0mm2 w/1-4,0mm2

*1,000V maximum in fixtures and signs

Model A B C D E

451® 15/64 11/32 11/16 5/16 1-1/646 9 18 8 26

452® 21/64 15/32 15/16 5/16 1-15/648.5 12 24 8 31.5

454® 7/16 5/8 1-3/16 13/32 1-15/3211 16 30 10.5 37.5

92® 21/64 13/32 29/32 9/32 1-5/328.5 10.5 23 10 30

Dimensions Inchesmm( )

Min2 #18

Min2 #18

Min3 #12

Max 3 #12

Max 4 #10 Max

1 #6 & 2 #8

451 Yellow

452 Red

454 Blue

Wire Combinations

Model

2 #18 2 #14 3 #12 5 #12 4 #10 5 #10

Page 16: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

Wire

Co

nn

ecto

rs

www.idealindustries.com 1-800-435-0705 for Customer ServiceA-2

Wire-Nut® Wire Connectors

Wire Combination Wire CombinationModel Color Range Range (mm) Quantity Cat. No.

300V 300V Box of 100 30-071

71B® Gray 22 to 16 AWG ,34mm2 to 1,5mm2 Carton of 1,000 30-171

Min. 2 #22 – Max. 2 #16 Min. 2-,34mm2 Max. 3-1,5mm2 Keg of 25,000 (loose pack) 30-271Barrel of 150,000 30-871

300V 300VBox of 100 30-072

72B® Blue 22 to 14 AWG ,34mm2 to 2,5mm2 Carton of 1,000 30-172

Min. 2 #22 – Max. 3 #16 Min. 2-,34mm2 Max. 3-1,5mm2 Keg of 10,000 (loose pack) 30-272Barrel of 85,000 30-872

Box of 100 30-073600V* 600V* Jar of 300 30-073J

73B® Orange 22 to 14 AWG ,34mm2 to 2,5mm2 Carton of 1,000 30-173Min. 1 #18 & 1 #20 Min. 1-,75mm2 w/1-,50mm2 Keg of 10,000 (20 bags, 500 ea.) 30-273Max. 4 #16 & 1 #20 Max. 4-1,5mm2 w/1-,50mm2 Keg of 10,000 (loose pack) 30-673

Barrel of 50,000 30-873Box of 100 30-074

600V* 600V* Jar of 175 30-074J

74B® Yellow 18 to 12 AWG ,75mm2 to 4,0mm2 Carton of 1,000 30-174Min. 2 #18 Min. 2-,75mm2 Keg of 5,000 (10 bags, 500 ea.) 30-274

Max. 4 #14 & 1 #18 Max. 4-2,5mm2 w/1-,75mm2 Keg of 10,000 (loose pack) 30-674Barrel of 35,000 30-874

600V* 600V* Box of 100 30-07618 to 10 AWG ,75mm2 to 6,0mm2 Carton of 1,000 30-176

76B® Red Min. 2 #14 Min. 2-2,5mm2 Keg of 5,000 (20 bags, 250 ea.) 30-276Max. 2 #10 & 2 #12 Max. 2-6,0mm2 w/2-4,0mm2 Barrel of 15,000 30-876

*1,000V maximum in fixtures and signs

Tough, durablethermoplastic shell

Positive-gripdesign

Long, fully seatedsquare-wire spring

Threadedentry

Deep skirt,wide throat

ULRLIST

ED

- WIRE CON

N

C USEN 60-998-2-4

Model A B C D E

71B® 11/64 1/4 21/64 11/64 37/644.5 6.5 8 4.5 15

72B® 11/64 5/16 25/64 3/16 45/644.5 8 10 5 18

73B® 11/64 11/32 7/16 11/32 55/644.5 9 11 9 22

74B® 17/64 7/16 35/64 5/16 61/647 11 14 8 24

76B® 9/32 1/2 19/32 3/8 1-1/167 13 15 10 27

Dimensions Inchesmm( )

■ Five color-coded models cover a full range of wire sizes from 22 - 8 AWG

■ Fixed, square-wire spring creates its own threads — maintains a secure positive grip that will not relax over time

■ No pre-twisting required — positive grip design provides fast, easy installation

■ Deep, wide skirt helps protect against flash-over and turned-back strandsfor maximum dielectric protection

■ Reusable for easy circuit changes and additions

■ Tough, UL94V-2 flame-retardant shell rated at 105oC (221oF)

■ UL Listed to 486C and CSA certified to C22.2 #188; comply with FederalSpecification W-S-610E

■ Classified in accordance with IEC Publications 998-2 and 998-2-4

Page 17: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

If it’s IDEAL, it’s a quality connector — and the In-Sure™ Push-In Wire Connector is no exception.Color-coded, the clear polycarbonate housing allows for visual verification of every connection. The ergonomic design of the In-Sure is easier to grip which means more comfortable push-in connections. Perfect for OEM lighting manufacturing, prefabricated wiring systems and other OEM and branch circuit wiring applications. Simply push the wire in — the low insertion force makes it easy. UL Listed, CSA Certified and rated to 600V and 105C. In-Sure saves time and improves productivity while perfecting connections.

In-Sure™ Push-In Wire Connectors

IDEAL INDUSTRIES, INC.Becker Place, Sycamore, IL 60178, USA / 815-895-5181 • 800-435-0705 in USA

International offices: Australia • Brazil • Canada • China • Germany • Mexico • UKFor complete sales office contact information, visit us at:www.idealindustries.com

Rev. 12/08Form No. P-2854

Printed in USA©2008 IDEAL INDUSTRIES, INC.

Great for residential applications as well.

Models 32, 33, 34 Wire Combination Range

Solid #20 – #12 solid

Stranded #16 – #12 (19 strand or less)#18 (7 strand)

Stranded Tin-Bonded #18 – #14 (19 strand or less)

Model 39 Wire Combination Range

Solid #14 – #10 solid

Stranded #12 – #10 (19 strand or less)

Stranded Tin-Bonded #14 – #10 (19 strand or less)

12-18 AWG Color No. of Length Width Height Quantity Cat. No.Models Ports mm in. mm in. mm in.

Box of 100 30-1032

32 Red 2 19.81 0.78 13.21 0.52 9.65 0.38 Jar of 300 30-1032J

Box of 5000 30-1632

Box of 100 30-1033

33 Orange 3 19.81 0.78 17.53 0.69 9.65 0.38 Jar of 250 30-1033J

Box of 5000 30-1633

Box of 100 30-1034

34 Yellow 4 19.81 0.78 20.83 0.82 9.65 0.38 Jar of 200 30-1034J

Box of 5000 30-1634

Box of 50 30-1039

39 Blue 3 19.81 0.78 21.84 0.86 11.43 0.45 Jar of 150 30-1039J

Box of 5000 30-1639

COPPER TO COPPER ONLY. Do not use on aluminum.Temperature rating: 105°C (221°F) maximum600V maximum building wire, 1000V maximum signs or lighting fixtures

Color-coded for easy identification

Tin-plated copper bus system

Stainless steel inserts restrict pull-out

Check port for continuity testing

Visual verification of connection

10-14 AWG Model

(6 port model available soon)

Page 18: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

Form No. P-1608©2000 IDEAL INDUSTRIES, INC.

Rev. 5/06Printed in U.S.A.

IDEAL INDUSTRIES, INC.Becker Place, Sycamore, IL 60178, USA / 815-895-5181 • 800-435-0705 in USA

International offices: Australia • Brazil • Canada • China • Germany • India • Mexico • UK

For complete sales office contact information, visit us at:www.idealindustries.com

In-Sure™ Push-In Wire Connectors

The In-Sure™ Push-In Wire Connector from IDEAL. The fastest, easiest, no-twist push-inconnector. Perfect for OEM lighting manufacturing, prefabricated wiring systems andother OEM and branch circuit wiring applications. The clear polycarbonate housing allows visual verification of every connection. Simply glide the wire in – the low insertionforce makes it easy. In-Sure™ also allows removal of the wire after the connection hasbeen established. UL Listed 94 D-Z, CSA Certified, and rated to 600V and 105°C. In-Sure™ saves time and improves productivity while perfecting connections.

Features• Accepts any combination of

12-18 AWG solid or tin-bonded copper conductors

• Electrolytic tin-plated copper bus system

• Stainless steel inserts restrict pull-out

• Available in 2 through 8 port models• Color-coded for easy identification• Each connector subjected to

3000V dielectric test• Check port for continuity testing• Built-in strip length gauge

Model Color No. of Length Width Height Quantity Cat. No.Ports in. mm in. mm in. mm

Box of 100 30-084Jar of 300 30-084J84 Red 2 .355 9.02 .434 11.02 .729 18.52Box of 1,000 30-184Box of 5,000 30-684Box of 100 30-085Jar of 250 30-085J85 Orange 3 .355 9.02 .591 15.01 .729 18.52Box of 1,000 30-185Box of 5,000 30-685Box of 100 30-086Jar of 200 30-086J86 Yellow 4 .355 9.02 .748 18.99 .729 18.52Box of 1,000 30-186Box of 4,000 30-686Box of 50 30-087Jar of 150 30-087J87 Gray 5 .355 9.02 .907 23.03 .729 18.52Box of 1,000 30-187Box of 5,000 30-687Box of 50 30-088Jar of 100 30-088J88 Blue 6 Stacked .607 15.42 .603 15.32 .729 18.52Box of 1,000 30-188Box of 5,000 30-688Box of 50 30-090Jar of 100 30-090J90 Black 8 .355 9.02 1.38 35.03 .717 18.21Box of 1,000 30-190Box of 2,000 30-690

Page 19: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

AFC

Ca

ble

Sys

tem

s C

ab

le C

ata

log

PRODUCT CATALOG

FeaturingAFC's ColorSpec™ ID System

MC TUFF® Cable

MC-Lite® Cable

HCF® Cable

Lighting, Power & Appliance Whips

Temp-Lites™

Page 20: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

Application(s) NEC® Type AC Type MC Type MOF

Hospitals, 517.13***** HCF-90, HCF-Lite Fire Alarm/Control

Nursing Homes, 250.118

Health Care Facilities

Places of Assembly* 518 HCF-90, HCF-Lite MC, MC-Lite, MC TUFF,

Fire Alarm/Control, Super Neutral,

Home Run, MC/OF, MC TUFF IG

Fire Alarm Systems, 760, 725.8(B) Fire Alarm/Control

Remote Control Circuits

Under Computer Room 330, 645 Super Neutral, MC TUFF IG

Raised Floors, Business

Equipment, Electronic

Discharge Lighting

Direct Burial in Wet, 330.10,*** Parking Deck/Lot

Dry, Oily Areas**

Multi-conductor Runs, 330 MC, MC-Lite, MC TUFF,

Commercial/Industrial/Utility Super Neutral, Home Run,

MC TUFF IG, Parking Deck/Lot

Robotics, Video Conferencing, 770 MC/OF MOF

Closed-Circuit TV, Factory

Automation

Redundant Ground 250.118, HCF-90, HCF-Lite MC TUFF IG

517.13, 645

Environmental 300.22(C), AC-90, AC-Lite, MC, MC-Lite, MC TUFF, MOF

Air-Handling Spaces 760.71(D)**** HCF-90, HCF-Lite Fire Alarm/Control, Super Neutral,

Home Run, MC/OF, MC TUFF IG

Branch Circuits in Hotels 320, 330 AC-90, AC-Lite MC, MC-Lite, MC TUFF

& Multi-family Dwellings

Office Partition Furniture 605 Super Neutral, MC TUFF IG

Parking Decks, Lots, Garages 330.10*** Parking Deck/Lot

Air Conditioners, Factory 330, 350, 356 Parking Deck/Lot

Installations with Wet, Dirty,

Oily Conditions

Lighting Whips, Motor Leads 320, 330, 348 AC-90, AC-Lite MC, MC TUFF, MC-Lite

2 AFC Cable Systems800-757-6996 www.afcweb.com

Cable Applications Chart

* Over 100 People

** Also hazardous locations up to Class 1, Div. 2

*** Also 230.43, 511.7, 513.7(A), 514.7, 515.7(A), 516.7(A)

**** Fire Alarm/Control Cable Only

***** HCF cables may not be used on emergency circuits in a health care setting. - Review NEC 517.30 (C)(3)(3)

NOTE: Local electrical codes may differ. Please consult appropriate authority.

THIS CHART HAS BEEN PREPARED AS A CONVENIENT REFERENCE TO SOME OF OUR PRODUCTS' MOST COMMON APPLICATIONS.

FOR MORE DETAILED INFORMATION, REFER TO THE APPROPRIATE SECTION OF THIS BROCHURE AND THE NEC.®

Page 21: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

MC

3800-757-6996 www.afcweb.comAFC Cable Systems

Type MC Metal Clad CablesType MC Cables – Uses Permitted:

The uses permitted for MC cable are governed by NEC®

Article 330 and any applicable local codes. Please referto NEC® Article 330 and your local authority havingjurisdiction for additional information.

• Where not subject to physical damage; For services, feeders and branch circuits

• For power, lighting, control and signalcircuits

• Indoors, exposed or concealed

• Outdoors or in wet locations where thearmor has an overall outer, moistureresistant PVC jacket and the conductors are wet rated

• Direct buried or in concrete encasementwhere identified for such use (ParkingDeck/Lot Cable™)

• Under raised floors, above suspendedceilings and in other environmental air-handling spaces per NEC 300.22(C)

• In places of assembly

• In cable tray or as open runs

• In locations classified as hazardous aspermitted in NEC Articles 501, 502, 503,504, and 505

• As aerial cable on a messenger

Type MC Cables – Uses Not Permitted:

• Where exposed to destructive corrosiveconditions unless the metallic sheath issuitable for the conditions or is protected by material suitable for the conditions

Type MC cables have 2 or more solid or stranded copper conductors in

sizes 18 AWG and larger.

The construction of AFC’s 600 Volt MC cable consists of copper circuit

and grounding conductors covered with thermoplastic insulation, an

overall polypropylene cable assembly tape and an outer galvanized steel

or aluminum interlocked armor.

The armor of interlocked Type MC cable is not an equipment grounding

means. Type MC cable requires a bare or green grounding conductor.

Type MC cable should be cut with an armored cable rotary cutter.

Rotary cutters have many advantages over other methods. Nicking and

cutting of the conductors is eliminated and the cuts can be made

quickly and safely.

In addition to our standard MC products, AFC offers lightweight

steel MC TUFF® and MC in a variety of specialty configurations, most

featuring the time saving ColorSpec™ ID System. These configurations,

specialty cables, are designed for applications such as fire alarm circuits,

direct burial or modular office furniture. This section describes the

different varieties of MC cable offered by AFC.

For more information about the proper use andapplication of AC & MC cables, visit AFC Universityon the Internet at www.afcweb.com/afcu

NEC® is a registered trademark of the National Fire Protection Association

Page 22: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

MC

8 AFC Cable Systems800-757-6996 www.afcweb.com

Product Codes, Trade Sizes, Conductors, Packaging & Weights

Grounding Approx. Armor Product Code Conductor Length (feet) Weight/1000 Minimum

Coil Reel Trade Size AWG Coil Reel Feet (lbs.) O.D. (inches)

1701B42T00 1701B60T00 14-2 Solid 14 250' 1000' 117 0.470

1702B42T00 1702B60T00 14-3 Solid 14 250' 1000' 140 0.480

1703B42T00 1703B60T00 14-4 Solid 14 250' 1000' 164 0.510

1704B42T00 1704B60T00 12-2 Solid 12 250' 1000' 147 0.495

1705B42T00 1705B60T00 12-3 Solid 12 250' 1000' 186 0.530

1706B42T00 1706B60T00 12-4 Solid 12 250' 1000' 223 0.565

1758B42T00 1758B60T00 12-2 Stranded 12 250' 1000' 152 0.495

1759B42T00 1759B60T00 12-3 Stranded 12 250' 1000' 191 0.530

1760B42T00 1760B60T00 12-4 Stranded 12 250' 1000' 225 0.565

1707B32T00 — 10-2 Solid 10 125' — 222 0.560

1708B32T00 — 10-3 Solid 10 125' — 268 0.600

1709B32T00 — 10-4 Solid 10 125' — 313 0.645

1707B42T00 1707B60T00 10-2 Solid 10 250' 1000' 222 0.560

1708B42T00 1708B60T00 10-3 Solid 10 250' 1000' 268 0.600

1709B42T00 1709B60T00 10-4 Solid 10 250' 1000' 313 0.645

1761B32T00 — 10-2 Stranded 10 125' — 227 0.560

1762B32T00 — 10-3 Stranded 10 125' — 269 0.600

1763B32T00 — 10-4 Stranded 10 125' — 319 0.645

1761B42T00 1761B60T00 10-2 Stranded 10 250' 1000' 227 0.560

1762B42T00 1762B60T00 10-3 Stranded 10 250' 1000' 269 0.600

1763B42T00 1763B60T00 10-4 Stranded 10 250' 1000' 319 0.645

Specialty Colors

1704B42T04 1704B60T04 12-2 Solid (red, white) 12 250' 1000' 147 0.495

1704B42T05 1704B60T05 12-2 Solid (blue, white) 12 250' 1000' 147 0.495

1705B42T04 1705B60T04 12-3 Solid (red, blue, white) 12 250' 1000' 147 0.495

1705B42T05 1705B60T05 12-3 Solid (black, blue, white) 12 250' 1000' 147 0.495

1707B42T04 1707B60T04 10-2 Solid (red, white) 10 250' 1000' 222 0.560

1707B42T05 1707B60T05 10-2 Solid (blue, white) 10 250' 1000' 222 0.560

1708B42T04 1708B60T04 10-3 Solid (red, blue, white) 10 250' 1000' 268 0.600

1708B42T05 1708B60T05 10-3 Solid (black, blue, white) 10 250' 1000' 268 0.600

MC TUFF® Lightweight Steel Metal Clad Cable(120 Volt colors) Technical Specifications

NOTE: All dimensions and weights are subject to normal manufacturing tolerances. WARNING: DO NOT RE-IDENTIFY CONDUCTOR COLORS.

Additional black stripe denotes 2 conductor cable

Additional black and red stripe denotes 3 conductor cable

Additional black, red and light blue stripes denote 4 conductor cable

Additional red and white stripesdenote special 2 conductor cable

Additional light blue and white stripesdenote special 2 conductor cable

Additional red, light blue and whitestripes denote special 3 conductor cable

Additional black, light blue and whitestripes denote special 3 conductor cable

Galvanized Steel Armor(Color-Coded Blue) Assembly Tape Copper

Conductors

Nylon ThermoplasticTHHN Insulation

CopperGround

Specification Description

Specification MC-TUFF ColorSpec™ ID System

Armor Galvanized Interlocking Steel Strip

(blue striped)

Conductors Solid/Stranded Copper (see below)

Conductor THHN/THWN (XHHW available by

Insulation special order subject to lead time and

minimum quantities)

Assembly Covering Polypropylene Tape

Maximum

Temperature 90°C (dry)

Rating

Grounding One grounding means – Insulated

Green Grounding Conductor

Neutral Conductor White

Maximum 600V

Voltage Rating

References & Ratings• U.L. 83, 1479, 1569, 1581,

File Reference E80042

• NEC 230.43, 300.22(C), 392, 396,

330, 518, 520, 530, 645

• Federal Specification A-A-59544

(formerly J-C-30B)

• Meets all applicable OSHA and

HUD Requirements

• May be surface mounted, fished and/or embedded in plaster

• Cable Tray installations per NEC

• U.L. Classified 1, 2 and 3-hour Through-Penetration Fire Wall File R-14929

• Environmental Air-Handling Space installation

AFC’s ColorSpec™ ID System

SET SCREW CONNECTORS MAY BE USED WITH STEEL CABLES, SEE CONNECTOR CROSS-REFERENCE GUIDE PAGE 30 FOR DETAILS.

Page 23: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

MC

9800-757-6996 www.afcweb.comAFC Cable Systems

Type MC Steel Metal Clad Cable (8 AWG-2 – 4/0 AWG-4 ) Technical Specifications

Galvanized SteelInterlocked Armor Assembly Tape

Stranded CopperConductors

CopperGround

Nylon ThermoplasticTHHN Insulation

Specification Description

Specification MC

Armor Galvanized Interlocking Steel Strip

Conductors Stranded Copper

Conductor THHN/THWN

Insulation

Assembly Polypropylene Tape

Covering

Maximum

Temperature 90°C (dry)

Rating

Grounding One grounding means – may be insulated

or bare, see chart below

Neutral Conductor White

Maximum 600V

Voltage Rating

References & Ratings• U.L. 83, 1479, 1569, 1581, File Reference E80042

• NEC 230.43, 300.22(C), 392, 396, 330, 518, 520, 530, 645

• Federal Specification A-A-59544 (formerly J-C-30B)

• Meets all applicable OSHA and HUD Requirements

• Cable Tray installations per NEC

• U.L. Classified 1, 2 and 3-hour Through-Penetration Fire Wall File R-14929

• Environmental Air-Handling Space installation

Product Codes, Trade Sizes, Conductors, Packaging & Weights

Grounding Approx. Armor Product Code Conductor Length (feet) Weight/1000 Minimum

Coil Reel Trade Size AWG Coil Reel Feet (lbs.) O.D. (inches)

Stock Items

1715-40-00 1715-45-00 8-2 Stranded 10 solid 200' 500' 329 0.635

1716-40-00 1716-45-00 8-3 Stranded 10 solid 200' 500' 432 0.685

1717-32-00 1717-45-00 8-4 Stranded 10 solid 125' 500' 511 0.835

1719-32-00 1719-45-00 6-2 Stranded 8 125' 500' 462 0.795

1720-32-00 1720-45-00 6-3 Stranded 8 125' 500' 594 0.855

1721-30-00 1721-45-00 6-4 Stranded 8 100' 500' 860 0.945

1724-30-00 1724-45-00 4-3 Stranded 8 100' 500' 985 1.035

1725-30-00 1725-45-00 4-4 Stranded 8 100' 500' 1195 1.135

1728-30-00 1728-45-00 3-3 Stranded 6 100' 500' 1070 1.025

1729-30-00 1729-45-00 3-4 Stranded 6 100' 500' 1260 1.120

1726-30-00 1726-45-00 2-3 Stranded 6 100' 500' 1340 1.180

1727-30-00 1727-45-00 2-4 Stranded 6 100' 500' 1640 1.295

1737-30-00 1737-45-00 1-3 Stranded 6 100' 500' 1530 1.185

1738-99-00 1738-99-00 1-4 Stranded 6 †† †† 1930 1.350

1770-99-00 1750-99-00 1/0-3 Stranded bare #6 †† †† 1780 1.255

1771-99-00 1751-99-00 1/0-4 Stranded bare #6 †† †† 2220 1.390

1772-99-00 1753-99-00 2/0-3 Stranded bare #6 †† †† 2095 1.350

1773-99-00 1754-99-00 2/0-4 Stranded bare #6 †† †† 2650 1.520

1774-99-00 1740-99-00 3/0-3 Stranded bare #4 †† †† 2580 1.520

1775-99-00 1741-99-00 3/0-4 Stranded bare #4 †† †† 3245 1.690

1776-99-00 1743-99-00 4/0-3 Stranded bare #4 †† †† 3040 1.580

1777-99-00 1744-99-00 4/0-4 Stranded bare #4 †† †† 3855 1.770

NOTE: All dimensions and weights are subject to normal manufacturing tolerances.

†† Cut to order.

XHHW INSULATION BY SPECIAL ORDER. CALL FOR DETAILS.

Page 24: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

MC

10 AFC Cable Systems800-757-6996 www.afcweb.com

Product Codes, Trade Sizes, Conductors, Packaging & Weights

Grounding Approx. Armor Product Code Conductor Length (feet) Weight/1000 Minimum

Coil Reel Trade Size AWG Coil Reel Feet (lbs.) O.D. (inches)

1704B42T01 1704B60T01 12-2 Solid (brown) 12 250' 1000' 147 0.495

1704B42T02 1704B60T02 12-2 Solid (orange) 12 250' 1000' 147 0.495

1704B42T03 1704B60T03 12-2 Solid (yellow) 12 250' 1000' 147 0.495

1704B42T07 1704B60T07 12-2 Solid (purple) 12 250' 1000' 147 0.495

1705B42T01 1705B60T01 12-3 Solid (brown, orange) 12 250' 1000' 186 0.530

1705B42T02 1705B60T02 12-3 Solid (orange, yellow) 12 250' 1000' 186 0.530

1705B42T03 1705B60T03 12-3 Solid (brown, yellow) 12 250' 1000' 186 0.530

1705B42T07 1705B60T07 12-3 Solid (brown, purple) 12 250' 1000' 186 0.530

1706B42T01 1706B60T01 12-4 Solid (brown, orange, yellow) 12 250' 1000' 223 0.565

1706B42T07 1706B60T07 12-4 Solid (brown, yellow, purple) 12 250' 1000' 223 0.565

1758B42T01 1758B60T01 12-2 Stranded (brown) 12 250' 1000' 152 0.495

1758B42T02 1758B60T02 12-2 Stranded (orange) 12 250' 1000' 152 0.495

1758B42T03 1758B60T03 12-2 Stranded (yellow) 12 250' 1000' 152 0.495

1759B42T01 1759B60T01 12-3 Stranded (brown, orange) 12 250' 1000' 191 0.530

1760B42T01 1760B60T01 12-4 Stranded (brown, orange, yellow) 12 250' 1000' 225 0.565

1707B42T01 1707B60T01 10-2 Solid (brown) 10 250' 1000' 222 0.560

1707B42T02 1707B60T02 10-2 Solid (orange) 10 250' 1000' 222 0.560

1707B42T03 1707B60T03 10-2 Solid (yellow) 10 250' 1000' 222 0.560

1707B42T07 1707B60T07 10-2 Solid (purple) 10 250' 1000' 222 0.560

1708B42T01 1708B60T01 10-3 Solid (brown, orange) 10 250' 1000' 268 0.600

1708B42T02 1708B60T02 10-3 Solid (orange, yellow) 10 250' 1000' 268 0.600

1708B42T03 1708B60T03 10-3 Solid (brown, yellow) 10 250' 1000' 268 0.600

1708B42T07 1708B60T07 10-3 Solid (brown, purple) 10 250' 1000' 268 0.600

1709B42T01 1709B60T01 10-4 Solid (brown, orange, yellow) 10 250' 1000 313 0.645

1709B42T07 1709B60T07 10-4 Solid (brown, yellow, purple) 10 250' 1000' 313 0.645

1761B42T01 1761B60T01 10-2 Stranded (brown) 10 250' 1000' 227 0.560

1762B42T01 1762B60T01 10-3 Stranded (brown, orange) 10 250' 1000' 269 0.600

1763B42T01 1763B60T01 10-4 Stranded (brown, orange, yellow) 10 250' 1000' 319 0.645

MC TUFF® Lightweight Steel Metal Clad Cable(480Y/277 Volt colors) Technical Specifications

NOTE: All dimensions and weights are subject to normal manufacturing tolerances. Other conductor colors available by special order. WARNING: DO NOT RE-IDENTIFY CONDUCTOR COLORS.

Additional brown stripe denotes

2 conductor cable (brown conductor)

Additional orange stripe denotes

2 conductor cable (orange conductor)

Additional yellow stripe denotes

2 conductor cable (yellow conductor)

Additional purple stripe denotes

2 conductor cable (purple conductor)

Additional brown and orange stripes

denote 3 conductor cable

Additional orange and yellow stripes

denote 3 conductor cable

Additional brown and yellow stripes

denote 3 conductor cable

Additional brown and purple stripes

denote 3 conductor cable

Additional brown, orange and

yellow stripes denote 4 conductor cable

Additional brown, yellow and purple

stripes denote 4 conductor cable

Galvanized Steel Armor(Color-Coded Blue) Assembly Tape Copper

Conductors

Nylon ThermoplasticTHHN Insulation

Copper Ground

Gray InsulatedNeutral

Specification Description

Specification MC TUFF ColorSpec™ ID System

Armor Galvanized Interlocking Steel Strip

(blue striped)

Conductors Solid or Stranded Copper (see below)

Conductor THHN/THWN (XHHW available by

Insulation special order subject to lead time and

minimum quantities)

Assembly Covering Polypropylene tape

Maximum

Temperature 90°C (dry)

Rating

Grounding One grounding means – Insulated

Green Grounding Conductor

(additional insulated

conductors optional)

Neutral Gray

Conductor

Maximum 600V

Voltage Rating

References & Ratings• U.L. 83, 1479, 1569, 1581,

File Reference E80042

• NEC 230.43, 300.22(C), 392, 396,

330, 518, 520, 530, 645

• Cable Tray installations per NEC

• Federal Specification A-A-59544

(formerly J-C-30B)

• Meets all applicable OSHA and HUD requirements

• May be surfaced mounted and embedded in plaster

• Environmental Air-Handling Space installation

• U.L. Classified 1, 2 and 3-hour Through-Penetration Fire Wall File R-14929

AFC’s ColorSpec™ ID System

SET SCREW CONNECTORS MAY BE USED WITH STEEL CABLES, SEE CONNECTOR CROSS-REFERENCE GUIDE PAGE 32 FOR DETAILS.

Page 25: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

Flex • AC • MC

Arlington Industries, Inc. www.aifittings.com • E-mail: [email protected]/233-4717 • FAX 570/562-0646

SeePages E-1 to E-4

38AST

40AST

45AST

50AST

Catalog Nos. 3810AST, 383810AST, 38AST, 38A, 380ST, 380AST, 3838AST, 3890AST

MC/HCF Cable Steel and Aluminum

AC/HCF Cable Steel and Aluminum

MCI-A (MCAP Cable) 3810AST & 383810AST

MCI-A (HCF MCAP Cable) 3810AST & 383810AST

Flexible Metal ConduitSteel and Aluminum (Regular and Reduced Wall)

MC Cable Continuous Corrugated Aluminum

CABLE TYPE CABLE RANGE

14/4, 12/2, 12/3, 12/4, 10/2

14/2, 14/3, 14/4, 12/2, 12/3, 12/4,10/2

14/2, 14/3, 14/4, 12/2, 12/3, 12/4,10/2

3/8" Trade SizeCSA Only - Use Anti-ShortBushing

Catalog Nos. 4010AST, 404010AST, 40AST,400AST, 4040AST, 4090AST

MC/HCF Cable Steel and Aluminum

AC/HCF Cable Steel and Aluminum

MCI-A (MCAP Cable) 4010AST & 404010AST

MCI-A (HCF MCAP Cable) 4010AST & 404010AST

Flexible Metal ConduitSteel and Aluminum (Regular and Reduced Wall)

MC Cable Continuous Corrugated Aluminum

CABLE TYPE CABLE RANGE14/2 w/gr.,14/4, 12/2 w/gr.,12/3, 12/3 w/gr., 10/2 w/gr., 10/3

12/2, 12/3, 12/4 10/2, 10/3, 10/4

14/4, 12/2 w/gr.,12/3, 12/4, 10/2 w/gr., 10/3

3/8" Trade SizeCSA Only - Use Anti-ShortBushing

Catalog Nos. 45AST, 50AST, 5090AST

MC/HCF Cable Steel and Aluminum

AC/HCF Cable Steel and Aluminum

Flexible Metal ConduitSteel and Aluminum (Regular and Reduced Wall)

CABLE TYPE CABLE RANGE

10/3to

6-2

8/3 to

4-2

1/2" Flex

45AST 50AST, 5090AST

• No Tools Required to Install• Saves Time and Money• Easy to Remove

PATENTED/PATENTS PENDING.

MCAP and HCF MCAP are registered trademarks of the Southwire® Company.

THEWIDESTCABLE RANGESFOR FLEX • AC • MC • HCF • MCI-A CABLE!

R

R

For overlapping cable ranges, use the larger fitting foreasier cable insertion

119575-LngfrdE 8/10/07 8:01 PM Page ii

creo
Page 26: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE

40AST 00041 3/8 1/2 50 500 1.410 .850 .405 1.000 .485-.612400AST 40347 3/8 1/2 50 500 1.280 .850 .400 1.000 .485-.61250AST 72300 1/2 1/2 50 500 1.660 1.130 .560 1.244 .860-.920

Refer to chart on page E-25 for a list of cable types.Concrete tight when taped.Flexible metal conduit, CSA listed with anti-short bushing (UL not applicable).SNAP-TITE® and SNAP2IT® products have been tested and listed by UL in accordance with UL’s ground fault requirements. For additional information see page 6.PATENTED. ADDITIONAL PATENTS PENDING.

CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE

38AST* 00070 3/8 1/2 50 500 1.410 .850 .405 1.000 .405-.61238A* 00038 3/8 1/2 50 500 1.410 .850 .405 1.000 .405-.612380ST 00381 3/8 1/2 50 500 1.280 .850 .400 1.000 .405-.612380AST* 00382 3/8 1/2 50 500 1.280 .850 .400 1.000 .405-.61245AST* 00045 1/2 1/2 50 500 1.660 1.130 .560 1.244 .590-.840

*Provided with insulated throat.

E-1 Flex • AC • MC

Arlington Industries, Inc.www.aifittings.com • E-mail: [email protected]/233-4717 • FAX 570/562-0646

380AST

R

R

E18304 LR49636

R

R

E18304 LR49636

SNAP2IT Connectors are EASY to Install... And EASY to Remove...

RED TINTING means‘OPEN TANG’ Design! It gives you more room inside the fitting for easy insertion of wires. The redesigned front end makes it easier than ever to snap the fitting into box!

COMPARE...

SNAP2IT®

ConnectorsZinc die-cast. For MC/HCF steeland aluminum cable • AC/HCFsteel and aluminum cable •Flexible metal conduit steel andaluminum (regular and reducedwall) • MC cable continuous corrugated aluminum.

FOR

EASIER MC/AC

INSTALLATIONS...

38AST38A

DC

B

A38AST

Using ascrewdriver,lift the ringand twistoff.

With Insulated Throat and Red Tinted Inside Clip38AST

40AST

Just snaponto cableand snapinto box!

NO TOOLS!• Safe and fast installations• Saves about 17 seconds

per fitting!• Competitively priced

38AST 40AST

See

3810AST & 4010AST

on Page E-2

119575-LngfrdE 8/10/07 8:01 PM Page 1

creo
osuarez
Highlight
osuarez
Line
Page 27: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

E-3 Flex • AC • MC

Arlington Industries, Inc.www.aifittings.com • E-mail: [email protected]/233-4717 • FAX 570/562-0646

*Provided with insulated throat.†Provided with insulated throat and red tinted inside clips. See comparison on page E-1.Refer to chart on page E-25 for a list of cable types.Concrete tight when taped.SNAP-TITE® and SNAP2IT® products have been tested and listed by UL in accordance with UL’s ground fault requirements. For additional information see page 6.PATENTED. ADDITIONAL PATENTS PENDING.

CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE

3838ST 10935 3/8 1/2 25 100 1.912 1.738 .970 .620 (2).405-.612

3838AST* 36230 3/8 1/2 25 100 1.962 1.738 .970 .620 (2).405-.612

4040AST† 40351 3/8 1/2 25 100 1.962 1.738 .970 .620 (2).485-.612

R

R

E18304 LR49636

A C

D

B

No Tools Required...Fully Assembled!Snap cables into connector andsnap assembly into box orfixture.

SNAP2IT® DuplexConnectorsZinc die-cast. For MC/HCF steeland aluminum cable • AC/HCFsteel and aluminum cable •Flexible metal conduit steel andaluminum (regular and reducedwall) • MC cable continuous corrugated aluminum.

383810AST

CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE

383810AST 10937 3/8 1/2 25 100 2.398 2.035 .840 .624 (2).370-.490

404010AST† 40533 3/8 1/2 25 100 2.398 2.165 .840 .624 (2).440-.612

404010AST

†Provided with red tinted inside clips so you candifferentiate a 383810AST from a 404010AST.Refer to chart on page E-25 for a list of cable types.Refer to chart on page E-26 for MCI-A (MCAP™ and HCF MCAP™) cable ranges.Concrete tight when taped.SNAP-TITE® and SNAP2IT® products have been tested and listed by UL in accordance with UL’s ground fault requirements. For additional information see page 6.PATENT PENDING.

R

R

E18304 LR49636

A

C

D

B

SNAP2IT® DuplexConnectors withInsulated ThroatZinc die-cast. For MC/HCF steeland aluminum cable • AC/HCFsteel and aluminum cable •Flexible metal conduit steel andaluminum (regular and reducedwall) • MC cable continuous corrugated aluminum • MCI-A(MCAP™ and HCF MCAP™) cable.

New!

Secure hold – Easy cable insertion!

FOR THE

WIDEST TOTAL

CABLE RANGES

MCAP and HCF MCAP are registered trademarks of the Southwire® Company.

Simply snap the cable into the fitting andsnap it into the box...no tools needed! The screw only holds the clip in place.

FOR

EASIER MC/AC

INSTALLATIONS...

See

383810AST & 404010AST

Above

119575-LngfrdE.2 9/11/07 12:14 AM Page 3

creo
osuarez
Highlight
osuarez
Line
osuarez
Line
osuarez
Line
Page 28: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL...Page 1 of 1 Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville |

E-14Flex • AC • MC

Arlington Industries, Inc. www.aifittings.com • E-mail: [email protected]/233-4717 • FAX 570/562-0646

CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLE END STOPNUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE DIAMETER

SG38AST*‡ 80144 3/8 1/2 50 500 1.203 .555 1.077 .405-.612 .400

SG380AST*‡ 80148 3/8 1/2 50 500 1.145 .555 1.077 .405-.612 .400 x .580

SG50ST‡ 80150 1/2 1/2 50 500 1.458 .510 1.235 .710-.910 .620

SG50AST*‡ 17501 1/2 1/2 50 500 1.145 .555 1.277 .710-.910 .620

SG75ST 18080 3/4 3/4 20 200 1.495 .510 1.570 .840-1.110 .820

SG75AST* 17755 3/4 3/4 20 200 1.540 .555 1.570 .840-1.110 .820

*Provided with insulated throat.‡Also for MCI-A (MCAP™ and HCF MCAP™) cable. Refer to page E-26 for cable ranges.Refer to chart on page E-25 for a list of cable types.Concrete tight when taped.For cables smaller than .405" see L16 and L16ST on page E-5.SNAP-TITE® products have been tested and listed by UL in accordance with UL’s ground fault requirements. For additional information see page 6.PATENTED.

CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE

SG3838ST 80152 3/8 1/2 25 100 .455 1.560 .780 (2) .445-.612SG3838AST* 36210 3/8 1/2 25 100 .605 1.610 .780 (2) .445-.612*Provided with insulated throat.Refer to chart on page E-24 for a list of cable types.Refer to chart on page E-26 for MCI-A (MCAP™ and HCF MCAP™) cable ranges.Concrete tight when taped.With independent securing of the cables, you can use two different size cables.SNAP-TITE® products have been tested and listed by UL in accordance with UL’s ground faultrequirements. For additional information see page 6.PATENTED.

SADDLEGRIP®

SNAP-TITE®

ConnectorsFor aluminum and steel Flex •AC • MC cable. Zinc die-cast.

SG38AST

SG380AST

R

R

E60812 LR49636

SG380AST SG38AST

R

R

E60812 LR49636

DuplexSADDLEGRIP®

SNAP-TITE®

ConnectorsZinc die-cast. For aluminumand steel Flex • AC • MCcable • MCI-A (MCAP™ andHCF MCAP™) cable.

A

B

C

A

B

C

MCAP and HCF MCAP are registered trademarks of the Southwire® Company.

119575-LngfrdE 8/10/07 8:01 PM Page 14

creo
osuarez
Highlight
osuarez
Highlight
osuarez
Line
osuarez
Line