numerical simulation of uhpc filled tube columns …399246/plse2015_46_zhang... · structures in...

8
NUMERICAL SIMULATION OF UHPC FILLED TUBE COLUMNS AGAINST BLAST LOADS Fangrui Zhang 1 , Chengqing Wu 1, 2* 1 School of Civil, Environmental and Mining Engineering, The University of Adelaide, SA 5005, Australia *Email: [email protected] 2 TCU-UA (Tianjin Chengjian University -- University of Adelaide) Joint Research Centre on Disaster Prevention and Mitigation ABSTRACT During the past decades, the use of concrete filled double skin steel tube (CFDST) members has gained much attention in the construction industry due to its beneficial properties such as light weight, high strength and excellent ductility. Many studies have discussed the behaviour of normal strength concrete filled CFDST member under a variety of load conditions; however, the knowledge of UHPC filled CFDST member is relatively lacking. This paper presents a numerical study on the ultra-high performance concrete filled double-skin tubes subjected to blast loading. Numerical models were developed in LS-DYNA and then validated against recently obtained experimental data. KEYWORDS Steel-fibre reinforced concrete; CFDST members; Blast loading; Numerical simulation INTRODUCTION Concrete-filled double skin steel tubes (CFDSTs), which are a newly developed steel-concrete composite structure, have the potential to be widely used in many engineering application ranging from columns of skyscrapers through to bridge piers. It involves the use of two concentrically placed steel tubes that is filled with concrete in between. This type of composite structure has advantages over other steel-concrete composite structures in the follow aspects: 1) the steel tubes can be directly used as permanent framework to the concrete filler; 2) The steel tubes provide confinement to the concrete filler while the infill of concrete can reduce the likelihood of local buckling of steel tubes (Zhao et al., 2010a). A number of experimental investigations showed that, for CFDSTs under axial compression, the passive confining pressure induced by steel tubes can effectively enhance the overall axial capacity by up to 30%; also, its failure mode was reported to be primarily decided by the ratio between the steel tube thickness and cross-sectional diameter (Wei et al., 1995, Zhao et al., 2010b). Furthermore, efforts were also put into studying the behaviours of CFDSTs under transverse loading (Han et al., 2006), tensile loading (Li et al., 2014), torsional loading (Huang et al., 2013) as well as fire (Lu et al., 2010), and they all have evidenced that CFDSTs are able to yield excellent performance under a variety of loading conditions. Although many studies have investigated the behaviours of CFDSTs under different circumstances, surprisingly little research has been on CFDSTs filled with ultra-high performance concrete (UHPC) considering its increasing popularity in the field of engineering. It is well known that, in comparison of normal strength concrete (NSC), UHPC is of higher strength and better ductility, enabling it to absorb a significant amount of energy before failure. Due to the presence of steel fibres, crack propagation within UHPC is also effectively delayed thus making it less prone to crushing or spalling damage when subjected to excessive loads. This property along with its superior strength and ductility together make UHPC an effective means of protecting important infrastructures against blast and impact loading as a result of increasing terrorist threats over the past years (Wu et al., 2009, Dragos et al., 2012). This paper numerically investigates the behaviours of CFDSTs filled with UHPC under transverse static loading as well as blast loading. The numerical modelling was conducted by using finite element tool LS-DYNA. The concrete material models in LS-DYNA, which was primarily developed for normal strength concrete only, was modified accordingly to accommodate the behaviours of UHPC. The proposed numerical model was also validated using data from a number of recent tests conducted on UHPC members. 386

Upload: others

Post on 18-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NUMERICAL SIMULATION OF UHPC FILLED TUBE COLUMNS …399246/PLSE2015_46_ZHANG... · structures in the follow aspects: 1) the steel tubes can be directly used as permanent framework

NUMERICAL SIMULATION OF UHPC FILLED TUBE COLUMNS AGAINST BLAST LOADS

Fangrui Zhang1, Chengqing Wu1, 2* 1School of Civil, Environmental and Mining Engineering, The University of Adelaide, SA 5005, Australia

*Email: [email protected] 2TCU-UA (Tianjin Chengjian University -- University of Adelaide) Joint Research Centre on Disaster

Prevention and Mitigation ABSTRACT During the past decades, the use of concrete filled double skin steel tube (CFDST) members has gained much attention in the construction industry due to its beneficial properties such as light weight, high strength and excellent ductility. Many studies have discussed the behaviour of normal strength concrete filled CFDST member under a variety of load conditions; however, the knowledge of UHPC filled CFDST member is relatively lacking. This paper presents a numerical study on the ultra-high performance concrete filled double-skin tubes subjected to blast loading. Numerical models were developed in LS-DYNA and then validated against recently obtained experimental data. KEYWORDS Steel-fibre reinforced concrete; CFDST members; Blast loading; Numerical simulation INTRODUCTION Concrete-filled double skin steel tubes (CFDSTs), which are a newly developed steel-concrete composite structure, have the potential to be widely used in many engineering application ranging from columns of skyscrapers through to bridge piers. It involves the use of two concentrically placed steel tubes that is filled with concrete in between. This type of composite structure has advantages over other steel-concrete composite structures in the follow aspects: 1) the steel tubes can be directly used as permanent framework to the concrete filler; 2) The steel tubes provide confinement to the concrete filler while the infill of concrete can reduce the likelihood of local buckling of steel tubes (Zhao et al., 2010a). A number of experimental investigations showed that, for CFDSTs under axial compression, the passive confining pressure induced by steel tubes can effectively enhance the overall axial capacity by up to 30%; also, its failure mode was reported to be primarily decided by the ratio between the steel tube thickness and cross-sectional diameter (Wei et al., 1995, Zhao et al., 2010b). Furthermore, efforts were also put into studying the behaviours of CFDSTs under transverse loading (Han et al., 2006), tensile loading (Li et al., 2014), torsional loading (Huang et al., 2013) as well as fire (Lu et al., 2010), and they all have evidenced that CFDSTs are able to yield excellent performance under a variety of loading conditions. Although many studies have investigated the behaviours of CFDSTs under different circumstances, surprisingly little research has been on CFDSTs filled with ultra-high performance concrete (UHPC) considering its increasing popularity in the field of engineering. It is well known that, in comparison of normal strength concrete (NSC), UHPC is of higher strength and better ductility, enabling it to absorb a significant amount of energy before failure. Due to the presence of steel fibres, crack propagation within UHPC is also effectively delayed thus making it less prone to crushing or spalling damage when subjected to excessive loads. This property along with its superior strength and ductility together make UHPC an effective means of protecting important infrastructures against blast and impact loading as a result of increasing terrorist threats over the past years (Wu et al., 2009, Dragos et al., 2012). This paper numerically investigates the behaviours of CFDSTs filled with UHPC under transverse static loading as well as blast loading. The numerical modelling was conducted by using finite element tool LS-DYNA. The concrete material models in LS-DYNA, which was primarily developed for normal strength concrete only, was modified accordingly to accommodate the behaviours of UHPC. The proposed numerical model was also validated using data from a number of recent tests conducted on UHPC members.

386

Page 2: NUMERICAL SIMULATION OF UHPC FILLED TUBE COLUMNS …399246/PLSE2015_46_ZHANG... · structures in the follow aspects: 1) the steel tubes can be directly used as permanent framework

FINITE ELEMENT MODELLING

Material Constitutive Models The numerical model was developed with 8-node solid elements with single point integration algorithm in LS-DYNA (Hallquist, 2007). There are several material models in LS-DYNA that can be used to simulate the behaviour of concrete structures (Wu et al., 2013, Wu et al., 2012). Among the available constitutive models, the K&C concrete model (also known as “MAT CONCRETE DAMAGE REL3”) is most widely used for its ability to model the behaviours of concrete members under complex loading conditions, including situations involving active/passive confining stress and/or high strain rate effect, with efficiency and accuracy (Crawford et al., 2012, Shi et al., 2008). The behaviours of UHPC differ from NSC significantly due to steel fibres and different mixture, however all concrete constitutive models in LS-DYNA were developed particularly based on normal strength concrete. Therefore, the default K&C concrete model, or any other existing models for this matter, cannot be directly applied to model UHPC. The K&C concrete model is defined by a number of material parameters, users can either manually input the values obtained from actual material tests or directly use the default values generated by the program itself. The mechanics behind this constitutive model along with each material input have been thoroughly explained by (Crawford et al., 2012, Mao et al., 2014), thus are not further discussed herein. In order to extend the existing K&C model to accommodate UHPC, the following material inputs were modified according to material tests that were conducted by the authors: 𝑤𝑙𝑧 , which governs the strain softening behaviour; ω, which governs the volume expansion (i.e. the confinement effect in this matter); λ and η, which governs the damage function and scale factor respectively. The key parameters for UHPC used in this research are listed in Table 1. It is evident from Figures 1 that, when validating against the four points bending test, good correlations were achieved between the numerical model and experiment result.

Table 1: Key parameters for K&C concrete model Model parameter Value 𝒇𝒄′ 170 MPa 𝒇𝒕 20 MPa Poisson’s ratio 0.19 B1 1.6 B2 1.35 𝒘𝒍𝒛 6.35 mm

Omega 0.9 (circular section) 0.1 (square section)

Figure 1: Four points bending test results

It is well known that under high strain rate impact, the strength of NSC increases significantly, by more than 100% for concrete in compression and by more than 600% for concrete in tension and the dynamic increase factor (DIF) for NSC can be calculated by the CEB Code (Béton, 1993, Malvar and Crawford, 1998). However,

387

Page 3: NUMERICAL SIMULATION OF UHPC FILLED TUBE COLUMNS …399246/PLSE2015_46_ZHANG... · structures in the follow aspects: 1) the steel tubes can be directly used as permanent framework

limited research on the strain rate effect on UHPC was conducted. Ngo et al. (Ngo et al., 2007) developed DIF model for UHPC with compressive strength up to 160 MPa, it was reported that the strain rate effect on UHPC was significantly smaller than the CEB Code prediction. In the current research, the dynamic properties of UHPC were investigated by using Split Hopkinson’s Pressure Bar (SHPB) test and the results are listed in Figure 2 (Su et al., 2015). It can be seen that, in comparison to NSC, the strain rate of UHPC did not have a significant effect until it reached 200/s for tension and 50/s for compression and the maximum DIF was also much smaller.

Figure 2: DIF for UHPC

Material model 24, namely MAT PIECEWISE LINEAR PLASTICITY, was used to represent the steel tubes. The actual stress-strain relationship obtained from tensile coupon test was inputted (as shown in Figure. 3) and the strain rate effect on the steel tube was incorporated by the Cowper and Symonds law which multiplies the yield stress by a factor given as:

𝐷𝐼𝐹 𝑜𝑓 𝑠𝑡𝑒𝑒𝑙 = 1 + (𝜀̇𝐶)

1𝑃

where 𝜀 ̇ = strain rate of steel. C = 808 𝑠−1 and P = 3.585 were used because good success was achieved by the authors in previous research by using this combination (Zhang et al., 2015).

Figure 3: Stress-strain relationship for the steel tube

Three Points Bending Test Three points bending tests were carried out to study the behaviours of UHPC filled CFDST specimens when subjected to static lateral load combined with axial load. As shown in Figure 4 that, the vertical hydraulic jack

388

Page 4: NUMERICAL SIMULATION OF UHPC FILLED TUBE COLUMNS …399246/PLSE2015_46_ZHANG... · structures in the follow aspects: 1) the steel tubes can be directly used as permanent framework

was displacement-controlled and the horizontal hydraulic jack was force-controlled. The specimen was simply supported near both ends by rollers and the axial load was applied by the horizontal hydraulic jack to only one end of the specimen.

Figure 4: Three points bending test setup

Figure 5 depicts the meshing of the numerical models. In both models, the characteristic length of each element was approximately 7.5 mm. Mesh convergence study suggested that, by further refining the mesh, only minor improvement can be made, however with a great increase in the computation time.

Figure 5: Meshing of numerical models

Table 2 and Figure 6 compare the numerical results to the experimental results of the three points bending test. It can be seen that, both circular and square models yielded less than 10% error in peak load and the overall behaviours also well agreed with the experimental observations. These results evidently confirmed the practicability and fidelity of numerically modelling UHPC filled CFDST specimens under static loads. Therefore, in the following section, the behaviours of UHPC filled CFDST specimens under blast loads were also numerically investigated in a similar manner.

Table 2: Summary of three points bending tests

Specimen No.

Outer dimensions (mm)

Inner dimensions (mm)

Tube thickness (mm)

Axial Load (kN)

Experimental Peak Load (kN)

LS-DYNA Peak Load (kN)

Error

C1 210 100 5 1000 484 440 -9.1% S1 210 100 5 1000 660 700 +6.1%

389

Page 5: NUMERICAL SIMULATION OF UHPC FILLED TUBE COLUMNS …399246/PLSE2015_46_ZHANG... · structures in the follow aspects: 1) the steel tubes can be directly used as permanent framework

Figure 6: Force-displacement histories of three points bending tests

Blast Test The experimental setup has been discussed by the authors in the previous study (Zhang et al., 2015), therefore only some important details are reiterated hereby. As shown in Figure 7, the test specimen was simply supported at both ends and bolts were used to provide an upward restraint against column rebound, thus making the effective span 2300 mm. The axial load was applied through a pneumatic jack at one end of the specimen only. Three LVDTs were installed along the specimen with 380 mm space between each other, in this paper, only the LVDT reading at the mid span is used for validation purpose.

Figure 7: Blast test setup

It can be concluded from Table 3 and Figure 8 that, the proposed numerical model not only accurately predicted the maximum mid-span deflection, with or without axil load, the predicted period of oscillation also corresponded with the experimental curve very well. Although discrepancy was found in the residual deflection, the difference was still within the acceptable range considering the complexity and uncertainty associated with blast experiments.

Table 3: Summary of blast tests

Specimen No.

TNT Equivalent

(Kg)

Axial Load (kN)

Standoff Distance

(mm)

Mid-span Deflection (mm)

Measured LS-DYNA Error (%)

S2A 50 0 1500 48 43 -10% S2B 50 1000 1500 40 37.1 -5%

390

Page 6: NUMERICAL SIMULATION OF UHPC FILLED TUBE COLUMNS …399246/PLSE2015_46_ZHANG... · structures in the follow aspects: 1) the steel tubes can be directly used as permanent framework

Figure 8: Displacement-time histories of blast tests

Effect of the axial load ratio Figure 9 shows the effect of axial load level on structural responses of CFDST specimens. It can be seen that, specimens with a small axial load ratio (e.g. 0.16 & 0.32) can result in a smaller maximum and plastic deflection compared to the axial-load-free specimen while a larger axial load ratio (e.g. 0.48) can significantly amplify the deflection. The amplification of deflection is caused by the “P-∆” effect: when a column deflects due to blast loads, the applied axial load causes a moment at each end which can further increases the deflection and as the deflection increases, the column reaches its plastic limit, transitioning from a gradual strength degradation to a rapid loss of strength due to buckling. Table 4 lists the results of the effect of axial load ratio.

Table 4: Effect of the axial load ratio

Axial load (kN)

Axial load ratio

Max. deflection (mm)

Plastic deflection (mm)

0 0 41.2 21.1

1000 0.16 37.1 14.5

2000 0.32 38.2 20

3000 0.48 44.4 33.6

Figure 9: Effect of axial load ratio

Effect of the outer & inner tube thickness It is suggested by Tables 5 & 6 and Figures 10 & 11 that, a thicker outer or inner steel tube can both reduce the deflection with having a thicker outer tube (for the same nominal steel ratio) being slightly more effective. Moreover, a thicker outer steel tube also shortens the column’s natural period of oscillation while this is not observed on a thicker inner steel tube.

391

Page 7: NUMERICAL SIMULATION OF UHPC FILLED TUBE COLUMNS …399246/PLSE2015_46_ZHANG... · structures in the follow aspects: 1) the steel tubes can be directly used as permanent framework

Table 5: Effect of the outer tube thickness Outer steel tube thickness (mm)

Nominal steel ratio

Max. deflection (mm)

Plastic deflection (mm)

1.67 0.124 63 35.4

3.33 0.173 45.8 20.7

5 0.222 37.1 14.7

Figure 10: Effect of the outer tube thickness

Table 6: Effect of the inner tube thickness

Inner steel tube thickness (mm)

Nominal steel ratio

Max. deflection (mm)

Plastic deflection (mm)

1.67 0.173 46.7 24.7

3.33 0.198 39.6 17.5

5 0.222 37.1 14.7

Figure 11: Effect of the inner tube thickness

CONCLUSIONS This paper presents a means of numerically modelling ultra-high performance concrete filled steel tubes under static as well as blast loading. The following conclusions can be made based on the content of this current research:

1. The existing concrete constitutive model, namely K&C concrete model, can be extended to accommodate the behaviour of UHPC by modifying some of its key parameters.

392

Page 8: NUMERICAL SIMULATION OF UHPC FILLED TUBE COLUMNS …399246/PLSE2015_46_ZHANG... · structures in the follow aspects: 1) the steel tubes can be directly used as permanent framework

2. Based on the validation studies presented in this paper, the proposed numerical models correlated well with the experimental results. For both static and dynamic loading cases, the errors yielded by the numerical models were kept well below 10%.

3. Compared to non-axially loaded columns, a small axial load can result in a smaller deflection while a large axial load level can significantly amplify the column deflection.

4. A thicker outer or inner steel tube can both reduce the deflection, however this effect is more noticeable on with a thicker outer tube rather than a thicker inner tube for the same nominal steel ratio.

ACKNOWLEDGMENTS The authors gratefully acknowledge the National Natural Science Foundation of China under Grants 51108106 and the ARC Discovery Grants DP130100181 andDP140103025. REFERENCES Béton, C. E.-I. D. 1993. CEB-FIP model code 1990: design code, Telford. Crawford, J., Wu, Y., Magallanes, J. & Lan, S. 2012. Use and Validation of the Release II K&C Concrete

Material Model in LS-DYNA. Karagozian & Case, Glendale. Dragos, J., Wu, C., Haskett, M. & Oehlers, D. 2012. Derivation of Normalized Pressure Impulse Curves for

Flexural Ultra High Performance Concrete Slabs. Journal of Structural Engineering, 139, 875-885. Hallquist, J. O. 2007. LS-DYNA Keyword User’s Manual. Livermore Software Technology Corporation. Han, L.-H., Huang, H., Tao, Z. & Zhao, X.-L. 2006. Concrete-filled Double Skin Steel Tubular (CFDST) Beam–

columns Subjected to Cyclic Bending. Engineering Structures, 28, 1698-1714. Huang, H., Han, L.-H. & Zhao, X.-L. 2013. Investigation on concrete filled double skin steel tubes (CFDSTs)

under pure torsion. Journal of Constructional Steel Research, 90, 221-234. Li, W., Han, L.-H. & Chan, T.-M. 2014. Tensile behaviour of concrete-filled double-skin steel tubular members.

Journal of Constructional Steel Research, 99, 35-46. Lu, H., Zhao, X.-L. & Han, L.-H. 2010. Testing of self-consolidating concrete-filled double skin tubular stub

columns exposed to fire. Journal of Constructional Steel Research, 66, 1069-1080. Malvar, L. J. & Crawford, J. E. 1998. Dynamic Increase Factors for Concrete. DTIC Document. Mao, L., Barnett, S., Begg, D., Schleyer, G. & Wight, G. 2014. Numerical simulation of ultra high performance

fibre reinforced concrete panel subjected to blast loading. International Journal of Impact Engineering, 64, 91-100.

Ngo, T., Mendis, P. & Krauthammer, T. 2007. Behavior of ultrahigh-strength prestressed concrete panels subjected to blast loading. Journal of Structural Engineering, 133, 1582-1590.

Shi, Y., Hao, H. & Li, Z.-X. 2008. Numerical Derivation of Pressure–Impulse Diagrams for Prediction of RC Column Damage to Blast Loads. International Journal of Impact Engineering, 35, 1213-1227.

Su, Y., Li, J., Wu, C., Wu, P. & Li, Z. 2015. Effects of Steel Fibres on Dynamic Strength of UHPC. The University of Adelaide. Manuscript submitted for publication.

Wei, S., Mau, S., Vipulanandan, C. & Mantrala, S. 1995. Performance of New Sandwich Tube under Axial Loading: Experiment. Journal of Structural Engineering, 121, 1806-1814.

Wu, C., Oehlers, D. J., Rebentrost, M., Leach, J. & Whittaker, A. S. 2009. Blast Testing of Ultra-High Performance Fibre and FRP-Retrofitted Concrete Slabs. Engineering Structures, 31, 2060-2069.

Wu, Y., Crawford, J. E., Lan, S. & Magallanes, J. M. 2013. Validation Studies for Concrete Constitutive Models with Blast Test Data. 13th International LS-DYNA Users Conference. Detroit.

Wu, Y., Crawford, J. E. & Magallanes, J. M. Performance of LS-DYNA concrete constitutive models. 12th International LS-DYNA Users Conference, 2012.

Zhang, F., Wu, C., Wang, H. & Zhou, Y. 2015. Numerical simulation of concrete filled steel tube columns against BLAST loads. Thin-Walled Structures, 92, 82-92.

Zhao, X.-L., Han, L.-H. & Lu, H. 2010a. Concrete-filled tubular members and connections, Oxford, Taylor & Francis.

Zhao, X.-L., Tong, L.-W. & Wang, X.-Y. 2010b. CFDST stub columns subjected to large deformation axial loading. Engineering Structures, 32, 692-703.

393