    Note

    Sub:ChangeinspecificationofMultistageCentrifugalpumpwithmotorfortheprojectHFCV/BARC/12

    Reg: ItemswithtagNos:P1HFTF01

    P2HFTF01

    M1HFTF

    01

    M2HFTF01

    TheSpecificationofmultistagecentrifugalpumpwithmotorhasbeenrevisedasfollows.

    Specification RevisedValue originalValue

    MaximumFlowRate 60m3/hr 70m3/hr

    MaximumHead 75bar 80bar

    Thedetailedrevisedspecificationisattachedherewith(Encl1).

    ThesechangeshavebeenapprovedbyBARC.Therelevantcommunicationdocumentsalsoattached

    (Encl2).

    MPRforthisitemwasalreadyissuedbasedonanearlierdesignrevision.Thedetailsareasfollows.

    MPRNo:139

    MPRDate:04.09.2012

    ItisintendedtorefloatthisMPRformultistagecentrifugalpumpbyamendingitwithrevised

    specification.

    DirectormaykindlyapprovetorefloattheMPRwithnecessarychanges.

    JameshBabuM,JE Dr.SRammohan,CRE

    Director

    Encl1:DetailedSpecificationforMultistageCentrifugalpumpwithMotor

    Encl2:CopiesofrelevantemailCommunicationheldwithBARC

  • 8/12/2019 Note to Revise Spec

    2/6

    (Encl1)Sl No

    TAG number : P1-HFTF-01 &P2-HFTF-01

    Type : Multi Stage Centrifugal Pump

    Shaft Orientation : Horizontal

    Head developed by the pump/ shut off head: To be specified

    Flow at maximum required pressure : 60 m3/hr

    Operating flow and pressure range : 60 m3/hr and 75 bar

    Temperature : 80C

    Fluid medium : DM Water

    Speed : 3000 rpm

    Sealing : Gland Packing

    Details for gland packing and other s tatic seals : To be provided

    Noise level : Noise Level Less than 85 dB

    Lubricating system for the pump : To be specified

    Details of base plate, foundation requirements and anchoring : To be provided

    Details of suction and NPSH : Flooded suction

    Hydraulic performance Acceptance tests1:

    Hydrostatic test :

    Dynamic balance test :

    Set of special erecting and commissioning tools : To be specified

    Nominal Suction Size : 2 (65 mm) #150(ANSI B16.5)

    Nominal Delivery Size : 2 (50 mm) #600(ANSI B16.5)

    Casing :

    Impeller :

    Diffuser :

    Acoustic enclosures : If required

    Name plate : As per the tag number Specified

    START-UP SPARES :

    List and Quantity to be specified separately

    for 1 year operation

    Electric motor: Tag No.(M1-HFTF-01 & M2-HFTF-01)

    Type : 3Induction motor

    Power : 250kW (or suitable for above pump)

    Voltage : 415 10V

    Frequency: 50Hz

    Insulation : Class F

    Number of poles : 2

    Full load speed: 3000rpm

    Mounting : Horizontal foot mounting

    1: Tests will be witnessed by FCRI or its representatives

    Item description

    Testing and Supply of Pump with Motor:

    1

    ASTM A351 CF8 /CF8M or equivalent

    Spares

    Note: Complete catalogue, brochures and technical specifications has to be specified and supplied alongwith each items.

    Please Quote seperately for each items

    Required as per ISO 9906 or ANSI/HI 14.6

    or any other relevant standards

    MOC : (SS304/SS316)

  • 8/12/2019 Note to Revise Spec

    3/6

    From: Ram Mohan S

    To: jamesh Babu M

    Subject: Fwd: RE: HFCV - Main pump procurement = reg.

    Date: 13 March 2014 14:53:56

    Regards,

    Dr. Rammohan S,

    Fluid Control Research Institute,

    Kanjikode West, Palakkad - 678623

    0491-2566120/206/ extn. 1119 ; 09446346850

    9446346850Rammohan13-03-2014

    --- Original message follows ---

    Subject: RE: HFCV - Main pump procurement = reg.From: "N L SONI"

    To: "'Ram Mohan S'"

    CC: "[email protected]"

    Date: 13-03-2014 15:34

    DEAR SHRI RAMMOHAN S.,

    A MEETING WAS HELD TODAY AT BARC AND ACCEPTED YOUR PROPOSAL FOR TWO MAIN

    PUMPS OF HFTF. FORMAL LETTERS FOLLOWS.

    N.L. SONIHEAD, FLUID POWER & TRIBOLOGY SECTION,

    BHABHA ATOMIC RESEARCH CENTRE,

    R.T.D., HALL-3, TROMBAY, MUMBAI, 400085, INDIA

    PHONE (0) 022 25593980

    PHONE (RES) 022 64522965

    MOBILE 09224293690

    FAX - 022 25505151

    E MAIL - [email protected];[email protected]

    From:Ram Mohan S [mailto:[email protected]]Sent:Thursday, March 06, 2014 11:35 AMTo:N L SONICc:[email protected]:Fwd: HFCV - Main pump procurement = reg.

    4

    --- Original message follows ---

    Subject: HFCV - Main pump procurement = reg.

    From: Ram Mohan S

    To: "N L SONI"

    (Encl 2)

    mailto:[email protected]:[email protected]:[email protected]:[email protected]
  • 8/12/2019 Note to Revise Spec

    4/6

    CC: "[email protected]" , "customer care"

    Date: 05-03-2014 9:29

    sir,

    Please find attached request for changing the operating paramter specification ofthe Main pump of HFTF.

    Kindly inform your consent at the earliest.

    Regards,

    Dr. Rammohan S,

    Fluid Control Research Institute,

    Kanjikode West, Palakkad - 6786230491-2566120/206/ extn. 1119 ; 09446346850

    9446346850Rammohan05-03-2014

    (Encl 2)

  • 8/12/2019 Note to Revise Spec

    5/6

    FCRI/BARC/HFCV SRM/Shri. N. L. Son i,Head, Fluid Power & Tribology Section,Bhabha Atomic Research Centre,R.T.D., Hall-3, Trombay, Mumbai, 400085, India

    Sub. Main Pump specification - HFTFIn the HFTF facility two pumps connected in parallel, provide the required flow at the operatingpressure. A booster pump is also provided at the inlet of the main pumps. The booster pump is providedwith a flow rate of 140 m3/h at 3 bar pressure. The Main pump generate the required flow and_pressurefor the smooth operation of the loop during testing. The maximum pressure and flow rate requirements for HFCV, for flow capacity testsas per theprocedures are 62.9 bar@ 22m3/hand 110m3/h @ 58.7 bar(for both valves together). The permanentpressure drop due to all components other than HFCV, CVl & CV2 at rated flow is less than2 bar (ref:Design Basis Report-High Pressure High Flow Test Facility HFTF) Rev 14.). The control valves CV2 andCVl are provided to create the required pressure at the upstream of the HFCV under test.Considering these factors, two identical pumps having a delivery pressure of 70bar@60m3/h shouldsuffice the test requirement. As per the specification approved by BARC, the pressure and flowrequirements of the pumps are 75 bar@ 70m3/hTwo separate attempts were made to procure pumps with the above specification (75 bar.@ 70m3/h).Unfortunately only one party has quoted with the above specification with all wetted parts in Stainlesssteel with a delivery time of 7 months as these pumps are not in their standard range.It is requested that the operating parameters of the pumps may be modified as 60m3/h @ 75 barinstead of 7Sm 3/h @75 bar. All these pumps have a delivery period exceeding 5 months as they are notstandard models.The HQ curve of the second party quoted for both the above tenders is also attached here with. Thispump can develop 60m3/h @ 75 bar. This can develop 70m3h @ 72 bar (please refer attached pumpcurve) and will operate at best efficiency point BEP). Also the Booster pump is capable of delivering 3bar line pressure. Thus testing of an HFCV can be done with a single pump itself as anticipated in theMOU.It is requested that you may consider the above case and intimate the modification in the pumpspecification so as to proceed with tendering with modified specifications.~r. Rammohan S -Chief Research Engineer.

    M MT SYS.RvAC49

    FCRI RESOURCE FOR INDUSTRYA Premier Institute in S. Asia for R&D on Flow Products, Testing and Cal ibration as per ISO/SIS/ANSI StandardsSoftware, CFD fo r Design and Sel:ction and Noise & Vibration Analysis of Flow Elements, Specialised Training,

    (Encl 2)

  • 8/12/2019 Note to Revise Spec

    6/6