11785 SW Highway 212 – Suite 305 Clackamas, OR 97015-9050 (503) 650-0088 WWW.DIRIGOLAB.COM Non-CBI Northwest Mfg. 600 Polk Ave Red Lake Falls, MN 56750 Qualification Testing EPA Method 28WHH Project # 033-HHP-039-1 Wood Master Mini Indoor Pellet Boiler Contact: Mr. Bruce Gagner, President Email: [email protected] (800) 932-3629

Upload: others

Post on 29-Sep-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

11785 SW Highway 212 – Suite 305 Clackamas, OR 97015-9050 (503) 650-0088 WWW.DIRIGOLAB.COM

Non-CBI

Northwest Mfg. 600 Polk Ave Red Lake Falls, MN 56750

Qualification Testing EPA Method 28WHH Project # 033-HHP-039-1 Wood Master Mini Indoor Pellet Boiler

Contact: Mr. Bruce Gagner, President Email: [email protected] (800) 932-3629

Page 2: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 1 Non CBI

This page intentionally left blank.

Page 3: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 2 Non CBI

Contents Affidavit: ......................................................................................................................... 4

Introduction: .................................................................................................................. 5

Technician Notes: ......................................................................................................... 5

Test Procedures and Equipment: ............................................................................. 7 Sample Boxes ....................................................................................................................................... 8 HEX, Flow Meters, Thermopile ............................................................................................................. 9 Airflow Diagram ................................................................................................................................... 10

Statement of Estimated Uncertainty: ..................................................................... 10

Results: Hang Tag , Weighting and Data Summary: ............................................... 11

Process Operations: ................................................................................................... 13

Run Data: .................................................................................................................. 13

Test Fuel Properties: ............................................................................................... 14

Test Condition Summary: ....................................................................................... 16

Appliance Views: ......................................................................................................... 16 Front .................................................................................................................................................... 16 Left & Rear .......................................................................................................................................... 17 Right Side ............................................................................................................................................ 17 Front with Hopper and Burner Assembly ............................................................................................ 18

Sampling Locations: ................................................................................................ 19 Traverse and Sampling Points ............................................................................................................ 19

Sampling Methods: .................................................................................................. 20

System Schematic: .................................................................................................. 20

Sampling and Analytical Procedures: .................................................................... 20

Analytical Methods Description: ............................................................................ 21

Quality Control and Assurance Procedures and Results: ................................... 21

Appendices: ................................................................................................................. 22

Appendix A: Sampling and Analytical Procedures ............................................... 22

Appendix B: Alternate Procedures ........................................................................ 22

Appendix C: Complete Drawings, Manual, and Run Information: ....................... 22

Appendix D: Supporting Data ................................................................................ 22

Page 4: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 3 Non CBI

Appendix E: Calibration ......................................................................................... 23

Appendix F: Dirigo Laboratories Accreditations ................................................. 34

Page 5: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 4 Non CBI

Affidavit:

All testing and associated procedures were conducted at Dirigo Laboratories beginning 12/29/2014 and ending on 1/29/2015. Dirigo Laboratories is located at 11785 SE Highway 212 – Suite 305, Clackamas, OR 97015-9050. All EPA protocols from Methods 1, 2, 3, 4, 5, 28 WHH and ASTM 2618-13 were followed in the testing, sampling, analysis, and calibrations for these tests and all results are based on these methods. Particulate sampling was performed per EPA Method 5G sampling option 3 and ASTM E2515-11 Standard Test Method for Determination of Particulate Matter Emissions Collected in a Dilution Tunnel. Efficiency was calculated using EPA Method 28WHH and checked using CAN/CSA-B415.1-10 Performance Testing of Solid-Fuel Burning Heating Appliances.

The following people were associated with the testing, analysis and report writing associated with this project.

John Steinert

Gary Nelke

Ben Nelke

Page 6: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 5 Non CBI

Introduction: Northwest Mfg contracted with Dirigo Laboratories, Inc. to perform EPA qualification testing on the Wood Master Mini model, indoor pellet fired hydronic heater per EPA Method 28WHH voluntary wood fired hydronic heater program. Efficiency testing was also performed per CSA B-415.1-10 “Performance Testing of Solid-Fuel Burning Heating Appliances”. All test results apply solely to the Wood Master Mini Boiler. This test report shall not be reproduced except in full, without the written approval of Dirigo Laboratories, Inc.

Technician Notes:

Unit arrived at Dirigo Laboratories on December 8, 2014.

• Conditioning occurred on 12/29/2014-(over 10 hours at a medium draw). • Prior to start of testing the dilution tunnel was cleaned with a 12” Steel chimney

brush. • Run #1 occurred on December 30, 2014 – Category 4 • Run #2 occurred on December 30, 2014 – Category 3 • Run #3 occurred on December 31, 2014 – Category 2 –(thrown out) • Run #4 occurred on December 31, 2014 – Category 1 –(thrown out) • Run #5 occurred on Janurary 27, 2015 – Category 1 • Run #6 occurred on Janurary 28, 2015 – Category 1 • Run #7 occurred on January 28, 2015 – Category 2 • Run #8 occurred on January 29, 2015 - Category 2

Per Method 28WHH, client opted to perform 2 additional category 1 runs (runs 5 & 6) and average those results to achieve the emissions and efficiency as stated in this report. Per Method 28WHH, client opted to perform 2 additional category 2 runs (runs 7&8) and average those results to achieve the emissions and efficiency as stated in this report.

Page 7: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 6 Non CBI

Wood Heater Identification: • Appliance Tested: Wood Master Mini Boiler • Serial Number: MB30-0001 • Manufacturer: Northwest Manufacturing • Address: 600 Polk Ave SW • Phone: (800) 932-3629 • Contact: Bruce Gagner • Email: [email protected] • Catalyst: No • Heat exchange blower: N/A • Type: Hydronic Heater • Style: Indoor • Fuel: Pellet • Date Received: Monday, December 08, 2014 • Wood Heater Aging: 12/29/2014 • Testing Period – Start: Monday, December 29, 2014 Finish: Thursday,

January 29, 2015 • Test Location: Dirigo Laboratories, Inc. -11785 SE Highway 212 - Suite 305,

Clackamas, OR 97015 • Elevation: 30 Feet above sea level • Test Technician(s): Ben Nelke Gary Nelke • Test Observer(s): N/A

The Woodmaster Mini Boiler is manufactured by Northwest Manufacturing, Inc. of Red Lake Falls, MN. The unit is an automatic feed, wood pellet indoor hydronic heater and was tested to EPA Method 28 WHH protocol. All testing was conducted by Dirigo Laboratories, Inc. at 11785 SE Highway 212 – Suite 305, Clackamas, OR 97015.

Page 8: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 7 Non CBI

Test Procedures and Equipment:

All test procedures used followed EPA Methods 1, 2, 3, 4, 5, 5g option 3, 28 WHH, ASTM 2515-11 and CSA B-415.1-10.

Equipment List:

1. Flow Meter - Omega FTB-1421, 0.6 – 3.0 GPM – Load side. 2. Flow Meter - Omega FTB-1424, 3.0 – 30.0 GPM – Load side. 3. Flow Meter - Omega FTB-1425, 5.0-50.0 GPM – Boiler Side. 4. Flow Meter – Omega FTB-602B-T, 0.3 – 9 LPM- Load Side 5. Analyzer -California Analytical ZRE CO2/CO/O2 IR ANALYZER. 6. Delmhorst J-2000 Wood Moisture Meter. 7. Dayton 4c121 Blower for dilution tunnel -Emissions Booth #2. 8. ScienTech Balance Scale. 9. 10 lb Calibration Weight. 10. DigiWeigh Bench Shipping Scale. 11. APEX XC-60 Digital Emissions Sampling Box A. 12. APEX XC-60 Digital Emissions Sampling Box B. 13. Gast MOA-P122-AA Vacuum Pump -Analyzer. 14. Rice Lake 4'x7' floor scale w/digital weight indicator. 15. APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile.

Page 9: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 8 Non CBI

Sample Boxes

Page 10: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 9 Non CBI

HEX, Flow Meters, Thermopile

Page 11: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 10 Non CBI

CBI

Airflow Diagram

Statement of Estimated Uncertainty: The combined estimated uncertainty of measurement is ± 10% for emissions results1 and ± 4% for efficiency .

1ASTM E2515 – 11 Standard Test Method for Determination of Particulate Matter Emissions Collected by a Dilution Tunnel. Section X1.3.5

Page 12: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 11 Non CBI

Results: Hang Tag , Weighting and Data Summary:

Data Summary Part Aθ Wfuel MCave Qin Qout

Wood Run Load% Actual Actual Test Weight Wood Heat Heat

Category No Capacity Load Load Duration as-fired Moisture Input Output% of

Btu/hr max hrs lb % DB Btu Btu≤ 15% of

I 5&6 max ≤ 15,300 12,585 12.34 4.00 10.5 3.87 86,936 50,34016-24%

II 7&8 of max 16,320 to 24,480 21,097 20.68 4.43 16.9 3.87 139,511 93,35425-50%

III 2 of max 25,500 to 51,000 40,964 40.16 4.00 28.0 3.87 231,828 163,856Max

IV 1 capacity 101,577 99.59 4.00 65.0 3.87 538,173 406,308

Target Load

Btu/hr

102,000

Data Summary Part B

T2 Min E E Eg/hr Eg/kg ηdel ηSLM

Min StackRun Load% Return PM Output PM Output PM PM Delivered Loss

Category No Capacity H2O Temp Based Based Rate Factor Efficiency Efficiencylbs/MMBtu

°F Output g/MJ g/hr g/kg % %≤ 15% of

I 5&6 max 144.07 0.1007 0.0433 0.59 0.50 58.07 69.9516-24%

II 7&8 of max 142.67 0.1220 0.0525 1.17 0.70 66.90 83.9025-50%

III 2 of max 138.71 0.1276 0.0549 2.37 0.78 70.68 82.50Max

IV 1 capacity 131.00 0.0758 0.0326 3.49 0.49 75.50 86.2013.98

9.49

5.18

Emissions

g

2.33

ET

Total PM

Page 13: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 12 Non CBI

The Wood Master Mini Boiler meets the Phase 2 emission level of 0.32lbs/MMBtu heat output weighted average and the 18.0 g/hr cap limit using Table 2, EPA Method 28 WHH.

Hang Tag Information:

Manufacturer: Northwest Mfg

Model Number: Wood Master Mini

102,000 Btu/hr

8-Hour Output Rating: Qout-8hr 101,577 Btu/hr8-Hour Average

Efficiency: ηavg-8hr 76% (Using higher heating value)

81% (Using lower heating value)

Annual Efficiency Rating: ηavg 65% (Using higher heating value)

69% (Using lower heating value)

Particle Emissions: Eavg 1.36 Grams/hr (average)

0.11 Lbs/Million Btu Output

Manufacturer Maximum Rated Output

Year Round Use Weighting:

Weighting

Category Run No. Factor (Fi) ηdel,i x Fi ηdel-LHV,i x Fi Eg/MJ,i x Fi Eg/kg,i x Fi Elb/MMBtu,i x Fi Eg/hr,i x Fi

I 5&6 0.437 25.37659 27.32124 0.0189221 0.2192866 0.0440059 0.25783II 7&8 0.238 15.9222 17.14314 0.012495 0.167195 0.029036 0.27846III 2 0.275 19.437 20.92475 0.0150975 0.2145 0.03509 0.65175IV 1 0.050 3.775 4.064 0.00163 0.0245 0.00379 0.1745

Totals: 1.000 64.5 69.5 0.0481 0.63 0.11 1.36

Page 14: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 13 Non CBI

Process Operations:

The appliance was operated according to procedures as described in the Operations Manual. Manufacturer settings were used in the operation of the pellet boiler to achieve the required burn rates. No adjustments were made.

All exterior draft measurements around the unit for all runs were less than 1 ft3 per minute.

Run Data: All corresponding run data can be found in their respective folders supplied with this report.

Page 15: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 14 Non CBI

Test Fuel Properties: All fuel consisted of premium grade hard wood pellets manufactured by Indeck Energy, Inc. Fuel moisture content was 3.87% Dry Basis. Fuel analysis was performed by Twin Ports Testing of Superior, WI. See below.

Page 16: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 15 Non CBI

Page 17: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 16 Non CBI

Test Condition Summary:

Testing conditions for runs 1,2,3,4,5,6,7,& 8 fell within allowable specifications of Method 28WHH. Details of all run conditions can be found in corresponding run folders.

Appliance Views:

Front

Page 18: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 17 Non CBI

Left & Rear

Right Side

Page 19: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 18 Non CBI

Front with Hopper and Burner Assembly

Page 20: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 19 Non CBI

Sampling Locations: Sample ports are located 16.5 feet downstream from any disturbances and 4 feet upstream from any disturbances. Flow rate traverse data was collected 12 feet downstream from any disturbances and 5.5 feet upstream from any disturbances.

Traverse and Sampling Points

Page 21: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 20 Non CBI

Sampling Methods: A dual filter dry sampling train system (ASTM 2515-11 / 5G sample option 3) was used in collecting particulate samples. The dilution tunnel is 12 inches in diameter. All particulate sampling conditions per ASTM 2515-11 and method 5G option 3 were followed.

System Schematic:

Sampling and Analytical Procedures: All sampling and analytical procedures used followed EPA Methods 1, 2, 3, 4, 5, 5g and 28WHH, ASTM E2618-13, ASTM E2515-11, and CSA B-415.1-10.

Page 22: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 21 Non CBI

Analytical Methods Description: All sample recovery and analysis procedures followed EPA Method 5g3 procedures. At the end of each test run, filters were removed from their housings, dessicated for 24 hours, and then weighed to a constant weight per Method 5 section 11.0.

Quality Control and Assurance Procedures and Results:

Calibration procedures and results were conducted per ASTM 2515-11, EPA Method 1 through 5, 5g and Method 28WHH. Calibration certificates and results can be found in Appendix E.

Test method quality control procedures (leak checks, volume meter checks, stratification checks, proportionality results) followed the procedures outlined in Method 5.

Page 23: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 22 Non CBI

Appendices:

Appendix A: Sampling and Analytical Procedures All sampling and analytical procedures were performed by Gary Nelke, Ben Nelke. All procedures used were directly from ASTM 2515-11, EPA Methods 1, 2, 3, 4, 5, 5g and 28WHH. Stack loss efficiency testing was performed to CSA B-415.1-10.

Appendix B: Alternate Procedures

No alternate procedures were used.

Appendix C: Complete Drawings, Manual, and Run Information:

All drawings, manuals and run information have been submitted in separate digital folders .

Appendix D: Supporting Data

Supporting data has been submitted in separate digital folders with the report.

Page 24: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 23 Non CBI

Appendix E: Calibration

Page 25: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 24 Non CBI

Page 26: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 25 Non CBI

Page 27: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 26 Non CBI

Page 28: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 27 Non CBI

Page 29: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 28 Non CBI

Page 30: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 29 Non CBI

Page 31: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 30 Non CBI

Page 32: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 31 Non CBI

Page 33: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 32 Non CBI

Page 34: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 33 Non CBI

Page 35: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 34 Non CBI

Appendix F: Dirigo Laboratories Accreditations

Dirigo Laboratories is accredited by the U.S. Environmental Protection Agency for the certification of wood heaters pursuant to subpart AAA of 40 CFR Part 60, New Source Performance Standards For Residential Wood Heaters- Methods 28, 28A, 28WHH, 5G, 5H. Certificate Numbers 9 and 9M (mobile).

Dirigo Laboratories is accredited by the American Association Of Laboratory Accreditation to the following ISO Standards:

• ISO 17020: 2012 Criteria for Bodies for Perfoming Inspections • ISO 17025: 2005 Requirements for Testing Laboratories: Mechanical Testing • ISO 17065: 2012 Requirements for Bodies Operating Inspection Bodies.

Page 36: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 35 Non CBI

Page 37: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 36 Non CBI

Page 38: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 37 Non CBI

Page 39: Northwest Mfg. - WoodMaster · APEX AK 6000 Ambient Sampling Box. 16. Delta T- 20 junction Thermopile. Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Northwest Mfg. Wood Master Mini Boiler EPA Qualification Testing Project # 033-HHP-039-1

Prepared by Dirigo Laboratories, Inc.

Page | 38 Non CBI