nomoline - masimo.com · infant/neonatal, 2 mpn 4369 ... nomoline selection chart is the patient...
TRANSCRIPT
Advanced technology enables cost-effective, hassle-free sidestream capnography and gas monitoring
NomoLine™
No-moisture sampling lines for intubated and non-intubated patients in low- and high-humidity applications
NomoLineNomoLine technology eliminates common problems associated with conventional sidestream gas analysis. Incorporating a unique, patented polymer, NomoLine allows water in the sampling line to evaporate into the surrounding air, while leaving oxygen, carbon dioxide, and anesthetic gases unaffected, eliminating the need for a water trap and issues related to their handling. Designed for low-flow applications, with functionality in any orientation, NomoLine sampling lines can be used in a variety of clinical scenarios on both intubated and non-intubated adult, pediatric, infant, and neonatal patients, in both low- and high-humidity configurations.
Features
A selection of convenient, cost-effective single-patient-use products
> Feature: Patented polymer collects and removes water in the sampling line
> Benefit: Extends product life and eliminates the need for a water trap
> Feature: Designed for low tidal volumes and high breath rates
> Benefit: Suitable for a wide range of clinical applications
> Feature: Hydrophobic bacteria filter
> Benefit: Protects the ISA™ module from bacteria and water intrusion
> Feature: Cannulas with soft, ergonomically curved design
> Benefit: Greater patient comfort
> Feature: Leak-free, click-in gas sampling port connector
> Benefit: Easy-to-use sampling lines
NomoLine LH (Low-Humidity) Single-Patient-Use Sampling LinesSingle-patient-use sampling lines for short-term applications in low-humidity conditions. Available for intubated and non-intubated patients.
NomoLine HH (High-Humidity) Single-Patient-Use Sampling LinesSingle-patient-use sampling lines for long-term applications in high-humidity conditions. Available for intubated and non-intubated patients.
NomoLine LH Airway Adapter SetKey Applications: Critical careColor coded Infant and Infant/Neonatal Airway Adapter Sets: Pink
Adult/Pediatric, 2 m PN 3814
Adult/Pediatric, 3 m PN 3815
Infant, 2 m PN 3816
Infant/Neonatal, 2 m PN 4369
NomoLine LH Single Nasal Prong CO2 CannulaKey Applications: EMS, ED
Adult single prong PN 3826
Adult PN 3817
Pediatric PN 3818
Infant PN 3819
Adult with O2 PN 3820
Pediatric with O2 PN 3821
NomoLine LH Nasal CO2 CannulaKey Applications: EMS, ED
NomoLine LH Nasal CO2 Cannula with O2 DeliveryKey Applications: EMS, ED
NomoLine LH Nasal/Oral CO2 CannulaKey Applications: Procedural sedation, critical care, sleep lab, EP, EMS, ED, cath lab
NomoLine LH Nasal/Oral CO2 Cannula with O2 DeliveryKey Applications: Procedural sedation, critical care, sleep lab, EP, EMS, ED, cath lab
Adult PN 3822
Pediatric PN 3823
Adult with O2 PN 3824
Pediatric with O2 PN 3825
NomoLine HH Airway Adapter SetKey Applications: OR, EMS, EDColor coded Infant and Infant/Neonatal Airway Adapter Sets: Pink
Adult/Pediatric, 2 m PN 3827
Adult/Pediatric, 3 m PN 3828
Infant, 2 m PN 3829
Infant/Neonatal, 2 m PN 4367
NomoLine HH Single Nasal Prong CO2 CannulaKey Applications: Critical care, sleep lab, long-term pain management
Adult single prong PN 3839
Adult PN 3830
Pediatric PN 3831
Infant PN 3832
Adult with O2 PN 3833
Pediatric with O2 PN 3834
NomoLine HH Nasal CO2 CannulaKey Applications: Critical care, sleep lab, long-term pain management
NomoLine HH Nasal CO2 Cannula with O2 DeliveryKey Applications: Critical care, sleep lab, long-term pain management
NomoLine HH Nasal/Oral CO2 CannulaKey Applications: Critical care, sleep lab, long-term pain management
NomoLine HH Nasal/Oral CO2 Cannula with O2 DeliveryKey Applications: Critical care, sleep lab, long-term pain management
Adult PN 3835
Pediatric PN 3836
Adult with O2 PN 3837
Pediatric with O2 PN 3838
INTUBATED PATIENTS Ordering Information: Box of 25, single-patient use
NON-INTUBATED PATIENTS Ordering Information: Box of 25, single-patient use
INTUBATED PATIENTS Ordering Information: Box of 25, single-patient use
NON-INTUBATED PATIENTS Ordering Information: Box of 25, single-patient use
LH HH
NomoLine Selection Chart
Is the patient intubated?
YES NO
Does the patient need supplementary oxygen?
YES NO
Short Term
Nasal/Oral Cannulawith O2 delivery
Nasal Cannula with O2 delivery
• Adult PN 3820• Pediatric PN 3821
• Adult PN 3824• Pediatric PN 3825
LH
Long Term
HH Airway Adapter Set
• Adult/Pediatric, 2 m PN 3827• Adult/Pediatric, 3 m PN 3828• Infant, 2 m PN 3829• Infant/Neonatal, 2 m PN 4367
HH
Long Term
Nasal Cannula with O2 delivery
Nasal/Oral Cannula with O2 delivery
• Adult PN 3833• Pediatric PN 3834
• Adult PN 3837• Pediatric PN 3838
HH
Short Term
Nasal Cannula Nasal/Oral Cannula Single Nasal Prong
• Adult PN 3817• Pediatric PN 3818• Infant PN 3819
• Adult PN 3822• Pediatric PN 3823
• Adult PN 3826
LH Long Term
Nasal Cannula Nasal/Oral Cannula Single Nasal Prong
• Adult PN 3830• Pediatric PN 3831• Infant PN 3832
• Adult PN 3835• Pediatric PN 3836
• Adult PN 3839
HH
Short Term
LH Airway Adapter Set
• Adult/Pediatric, 2 m PN 3814• Adult/Pediatric, 3 m PN 3815• Infant, 2 m PN 3816• Infant/Neonatal, 2 m PN 4369
LH
Color coded Infant and Neonatal Airway Adapter Sets: Pink
Masimo Internationaltel [email protected]
Masimo U.S.tel 1-877-4-Masimo [email protected] 60
443/
PLM
-103
61B-
0318
© 2018 M
asimo. A
ll rights reserved.
Masimo Sweden ABTel: +46 8 544 98 150 [email protected]
Standard length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 m
Inline bacteria filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BFE ≥ 99.9%
Tubing inner diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 mm
Supplementary oxygen delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to 5 l/min
Airway Adapter dead space
Adult/Pediatric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≤ 6 ml Infant and Infant/Neonatal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤ 0.7 ml
Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not made with natural rubber latex
NomoLine Specifications
Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. See instructions for use for full prescribing information including indications, contraindications, warnings, and precautions.
How NomoLine Works
> Gas and condensed moisture from the patient’s expired breath enters the Nomo Section through the gas sample tube
> Condensed moisture and aspirated water are separated and collected using a hydrophilic absorbent
> Water molecules are diffused from the hydrophilic absorbent through the Nomo polymer cover
> Long-term use is possible as the water diffused through the Nomo polymer cover continuously evaporates into the surrounding air
> A hydrophobic bacteria filter protects the gas module from water intrusion and cross-contamination
> Gas and condensed moisture from the patient’s expired breath enters the Nomo Section through the gas sample tube
> Condensed moisture and aspirated water are separated and collected using a hydrophilic absorbent
> When the capacity of the hydrophilic absorbent is reached, the sampling line should be replaced
> A hydrophobic bacteria filter protects the gas module from water intrusion and cross-contamination
Gas sa
mple
from
patien
t circ
uitHH
Nomo polymer cover
Hydrophobic bacteria filter
Gas sampling port connector
Gas sample tube
Hydrophilic absorbent
Nomo Section
Gas sa
mple
from
patien
t circ
uit
Hydrophobic bacteria filter
Gas sampling port connector
Gas sample tube
Hydrophilic absorbent
CoverNomo Section
LH