nocchi
DESCRIPTION
ÂTRANSCRIPT
Production Program
Premier supplier of water equipmentPentair is a diversified operating company headquartered in Minnesota.Its Water Group is a global leader in providing innovative products andsystems used worldwide in the movement, treatment, storage andenjoyment of water.Pentair’s Enclosure group is leader in the global market of enclosuresfor sensitive electronics and electrical components.
Pentair is a values-driven company that brings superior products tocustomers through some of the world’s leading brands. Efforts incontinuous improvement, strong new product development, highperformance, competence, business ethics and market leadershiphave contributed greatly to our success. Pentair’s employees sharemany personal values such as accountability, deep respect for peopleand the environment, and a candid and practical work style.Strong customer relationships and quality products allow Pentair Waterto attain the vision of being the leading provider of water equipment.
Safe, clean water for people to drink andenjoy, and for industries to use
Pentair Water is playing a key role in making safe, clean water availableto an ever-growing portion of the world’s population: a valuableorganization is engaged to successfully serve our customers troughsuperior, decentralized and accountable operations and dedicated salesand marketing networks.
Pool and spaA complete line of commercialand resident ial pool /spaequipment and accessoriesincluding pumps, filters,heaters, lights, automation,automatic pool cleaners,commercial deck equipment,barbeque deck equipment,aquatic pond products andaccessories, pool tile andinterior finishing surfaces,maintenance equipment ,spa/jetted tub hydrotherapyfittings and pool/spa accessories.
Filtration & purificationTechnologiesResidential, commercial, andindustrial filtration housings;replaceable cartridge elements;carbon block filtration; drinkingwate r f i l t r a t ion sys temcomponents ; pumps forrecreational vehicles, marine,industrial applications and foodservice.
Pump SystemsProducts range from single andmultistage centrifugals tosha l low and deep we l lsubmersibles for residential,commercial and agricultureapplications; sump, effluent andsewage pumps designed forw a t e r a n d w a s t e w a t e rapplications; pressure boostingand fire fighting systems as wellas circulating pumps for heating,ventilation and air conditioning.
Water TreatmentResidential, commercial,industrial, water conditioningcontrol valves, fiberglass woundpressure tanks and vessels, brinecabinets and storage tanks.
Pentair Water operates through an organization that includes4 Business Units:
3
Water Energy
Heating, ventilationand air-conditioning
Circulator pumps for circulation of hot water in centralheating systems and circulation in domestic hot waterservice systems. Pumps for circulation of cold waterand other liquids in cooling and air-conditioning systems.
Reliable pumps providing waterenergy.Established in 1977, Nocchi is today a part of PentairWater group. For more than 25 years we have beendesigning and manufacturing water pumps providingour customers quality products and concrete solutions.Nocchi line is dedicated to engineering firms andplumbing and heating/cooling distributing centres.Within the full Nocchi range a professional customercan find products and innovative solutions to suit anyneed with regards to water supply and pressurizationin the realm of residential and commercial building,irrigation and industry applications.
Pressure boosting and fire fighting
Vertical and horizontal centrifugal pumps.Multiple pump units for transfer and boosting of water.Fire-fighting systems.
Sewage and wastewater
Drainage, effluent and sewage pumps, for a wide rangeof applications in building services.
Domestic water supply
Submersible pumps, jet pumps, multistage centrifugalpumps and compact systems for water and rain watersupply in home and garden applications.
Groundwater supplySubmersible pumps for groundwater supply, irrigationand groundwater lowering.
4
Circulating Pumps
SR3 R2S-R2SD
Applications
- Civil and industrial pressurized or open tank heating systems.
Usage limitations
- Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres- Liquid temperature: from +10° C to +110° C from -10° C to +110° C (SR3 25/70 mod.)- Maximum operating pressure: 10 bar- The pump must be installed with the driving shaft in horizontal position- threaded port
Technical data
Flow : Q max. 5.5 m3/hHead : H max. 7 m
Applications
- Civil and industrial pressurized or open tank heating systems.
Usage limitations
- Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres- Liquid temperature: from +10° C to +110° C- Maximum operating pressure: 10 bar- The pump must be installed with the driving shaft in horizontal position- Series 32 threaded ports Series 42 flanged ports
Technical data
Flow : Q max. 10 m3/hHead : H max. 8,5 m
R2X-R2B
Applications
- Sanitary hot water circulation systems, heating and conditioning systems.
Usage limitations
- Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres- Lime-stone free water (if water exceeds 35° F a softener device must be installed)- Suggested water temperature max 60° C- Maximum operating pressure: 10 bar- The pump must be installed with the driving shaft in horizontal position
Technical data
Flow : Q max. 10 m3/hHead : H max. 9 m
CIRCULATING PUMPSFOR HEATING DOMESTICSYSTEMS
CIRCULATING PUMPS AND TWINCIRCULATING PUMPS FORHEATING DOMESTIC SYSTEMS
BRONZE-STAINLESS STEELCIRCULATING PUMPSFOR DOMESTIC WATER
H (m)
10
0,2
1
3
5
8
0,6 1 3 5 8 10 Q (m3/h)
10
0,3 10,6 3 6
4
1
0,1
0,4
0,8
6
Q (m3/h)
H (m)
10
0,2
1
3
5
8
0,6 1 3 5 8 10
H (m)
Q (m3/h)6
4
5
R2C-R4C R2CD-R4CD R2T-R4T
Applications
- Pressurized or open tank heating systems- Air-conditioning systems- Domestic hot water distribution systems.
Usage limitations
- Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres- Hot water or coolants not containing mineral oils- Liquid temperature: from -20° C to +130° C- Maximum operating pressure: 10 bar- The pump must be installed with the driving shaft in a horizontal position- Flanged ports: DN 40-50-65 PN 6/10 DN 80-100 PN 6 DN 80-100 PN 10
Technical data
Flow : Q max. 90 m3/hHead : H max. 18 m
Applications
- Pressurized or open tank heating systems- Air-conditioning systems- Domestic hot water distribution systems.
Usage limitations
- Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres- Hot water or coolants not containing mineral oils- Liquid temperature: from -20° C to +130° C- Maximum operating pressure: 10 bar- The pump must be installed with the driving shaft in a horizontal position- Flanged ports: DN 40-50-65 PN 6/10 DN 80-100 PN 6 DN 80-100 PN 10
Technical data
Flow : Q max. 90 m3/hHead : H max. 18 mWith only one head in operation
Applications
- Heating and air-conditioning systems- Water supply systems- Booster systems- Agriculture and fruit and vegetable crops.
Usage limitations
- Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres- Hot water or coolants not containing mineral oils- Liquid temperature: from -20° C to +130° C- Maximum operating pressure: 10 bar- Maximum environmental temperature: 40° C- The pump may be installed with the driving shaft in all positions between horizontal and vertical- Flanged ports: DN 40-50-65 PN 6/10 DN 80-100 PN 6 DN 80-100 PN 10
Technical data
Flow : Q max. 85 m3/hHead : H max. 18 m
Circulating Pumps
MULTI SPEED SINGLE-HEADCIRCULATING PUMPS
MULTI SPEED TWIN-HEADCIRCULATING PUMPS
SINGLE-HEAD CIRCULATINGPUMPS WITH MECHANICAL SEAL
Q (m3/h)
20
16
1210
8
65
4
3
2
12 3 4 5 7 10 20 30 40 60 80
H (m)
Q (m3/h)
20
16
1210
8
65
4
3
2
12 3 4 5 7 10 20 30 40 60 80
H (m)
20
16
1210
8
65
4
3
2
12 3 4 5 6 7 8 10 20 30 40 60 100 Q (m3/h)
H (m)
6
Circulating Pumps
R2TD-R4TD A2L - A4L
Applications
- Heating and air-conditioning systems- Water supply systems- Booster systems- Agriculture and fruit and vegetable crops
Usage limitations
- Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres- Hot water or coolants not containing mineral oils- Liquid temperature: from -20° C to +130° C- Maximum operating pressure: 10 bar- Maximum environmental temperature: 40° C- The pump may be installed with the driving shaft in all positions between horizontal and vertical- Flanged ports: DN 40-50-65 PN 6/10 DN 80-100 PN 6 or PN 10
Technical data
Flow : Q max. 85 m3/hHead : H max. 18 mWith only one head in operation
Applications
- Heating and air-conditioning systems- Water lifting from lakes, rivers, well etc.- Irrigation systems on ground surface or by sprinkling.- Water supply and distribution for isolated houses or small villages.- Pressure systems.- Industrial services.- Domestic hot water supply systems.
Usage limitations
- Max working pressure: 10 bar .- Max liquid temperature: +130° C- Min. liquid temperature : -10° C- Max environmental temperature : +40°C- Max liquid viscosity : 5° E
Technical data
Flow : Q max. 300 m3/hHead : H max. 68 m
A2LD-A4LD
Technical data
Flow : Q max. 225 m3/hHead : H max. 40 mWith only one head in operation
TWIN HEAD CIRCULATING PUMPSWITH MECHANICAL SEAL
SINGLE-HEAD CIRCULATING"IN LINE" ELECTRIC PUMPSWITH MECHANICAL SEAL
“IN LINE” TWIN HEADCIRCULATING PUMPSWITH MECHANICAL SEAL
20
16
1210
8
65
4
3
2
12 3 4 5 6 7 8 10 20 30 40 60 100 Q (m3/h)
H (m)
50
40
30
25
20
15
10
8
6
5
43 6 12 24 60 120 180
60
H (m)
Q (m3/h)
50
40
30
25
20
15
10
8
6
5
41,2 3 6 12 24 60 120 180 240
60
H (m)
Q (m3/h)
Applications
- Heating and air-conditioning systems- Water lifting from lakes , rivers, wells, etc.- Irrigation systems on ground surface or by sprinkling.- Water supply and distribution for isolated houses or small villages.- Pressure systems.- Industrial services.- Domestic hot water supply systems.
Usage limitations
- Max working pressure: 10 bar .- Max liquid temperature: +130° C- Min. liquid temperature : -10° C- Max environmental temperature : +40°C- Max liquid viscosity : 5° E
7
VLR VLRX-VLRI
Applications
- Water supply- Pressure Booster Systems- Irrigation- High pressure washes- Firefighting systems- Boiler supply- Liquid transfer
Usage limitations
- Max liquid temperature: +120° C- Min. liquid temperature : -20° C- Max working pressure: 25 bar
Technical data
Flow : Q max. 72 m3/hHead : H max. 260 m
Applications
- Water supply- Pressure Booster Systems- Irrigation- High pressure washes- Firefighting systems- Boiler supply- Liquid transfer
Technical data
Flow : Q max. 21 m3/hHead : H max. 260 m
Surface Pumps
Usage limitations
- Max liquid temperature: +120° C- Min. liquid temperature : -15° C- Max working pressure: 25 bar
MULTINOX VE
Applications
- Pumping and distribution of water in domestic systems used on a continuous or intermittent basis- Booster systems- Washing systems, garden irrigation fountains- Firefighting systems
Usage limitations
- Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres- Maximum liquid temperature 50° C- Maximum recommended suction height 6 m with foot valve- Maximum operating pressure: 9 bar 12 bar (MULTINOX VE 200/110)
Technical data
Flow : Q max. 9,6 m3/hHead : H max. 110 m
VERTICAL MULTISTAGECENTRIFUGAL PUMPS
VERTICAL MULTISTAGECENTRIFUGAL PUMPS IN AISI 316STAINLESS STEEL
MULTISTAGECENTRIFUGAL PUMPS
1 2 3 4 6 10 20 40 60 100
300
200
100
80
60
40
30
20Q (m3/h)
H (m)
1 2 3 4 6 10 20 40 60 100
300
200
100
80
60
40
30
20Q (m3/h)
H (m)
Versions available
“F” "in line" round flange“A” "in line" oval flange
Versions available
“F” "in line" round flange“A” "in line" oval flange“V” with couplings for victaulic joints
80 40L / 1'm3/ h
Q
100
60
40
80
2,4 9,64,8
160
30
50
70
90
120
7,2
60
3,6
100
6,0
140
8,4 10,8
180
120
0
H (m)
8
Surface Pumps
DHI
Applications
- Aggressive liquids transfer- Pumping and distribution of water in domestic systems used on a continuous or intermittent basis- Booster systems- Washing systems, garden irrigation, fountains
Usage limitations
- Types of pumped liquid: clear, nonexplosive with no suspended solids or abrasive material- Maximum liquid temperature 90° C- Maximum operating pressure 6 bar
Technical data
Flow : Q max. 7 m3/hHead : H max. 63 m
DHR
Applications
- Pumping and distribution of water in domestic systems used on a continuous or intermittent basis- Booster systems- Washing systems, garden irrigation, fountains- Air-conditioning systems
Usage limitations
Non-aggressive and non-explosiveclean liquids free of suspended solidparticles and fibres- Maximum liquid temperature 90° C- Maximum operating pressure: 10 bar
Technical data
Flow : Q max. 15 m3/hHead : H max. 60 m
MCX
Applications
- Pumping and distribution of water in domestic systems- Booster systems- Firefighting systems- Washing systems, irrigation
Usage limitations
- Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres- Maximum liquid temperature 50° C- Maximum operating pressure 7 bar
Technical data
Flow : Q max. 10 m3/hHead : H max. 65 m
STAINLESS STEEL AISI 316MULTISTAGE CENTRIFUGALPUMPS
MULTISTAGE CENTRIFUGALPUMPS WITH STAINLESS STEELIMPELLERS AND DIFFUSORS
MULTISTAGECENTRIFUGAL PUMPS
20 40 10060 12080
1,2 2,4 6,03,6 7,24,8
10
20
30
40
50
60
HmL / 1'm3/ h
Q
80
40
12
200120
7,2
50 100 250150 300200
3 6 159 1812
10
20
30
40
50
60
HmL / 1'm3/ h
Q 40L / 1'm3/ h
Q
30
60
2,4
10
20
50
70
20
1,2
80
4,8 96
160
Hm
9
Surface Pumps
MULTINOX
Applications
- Pumping and distribution of water in domestic systems- Booster systems- Firefighting systems- Washing systems- Irrigation
Technical data
Flow : Q max. 10 m3/hHead : H max. 80 m
Usage limitations
Non-aggressive and non-explosiveclean liquids free of suspended solidparticles and fibres- Maximum liquid temperature 50° C- Maximum operating pressure 9 bar
MULTISTAGECENTRIFUGAL PUMPMULTINOX-A self-priming
200
Hm
L / 1'
m3/ h
20
40 2,4
80 4,8
10
30
40
50
60
80
70
12 160 9,6
120 7,2
Q
MAX
Applications
- Pumping and distribution of water in domestic systems- Booster systems- Firefighting systems- Washing systems, irrigation
Technical data
Flow : Q max. 6 m3/hHead : H max. 55 m
Usage limitations
- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 50° C- Maximum operating pressure 7 bar
MULTISTAGE SELF-PRIMINGPUMPS
20 40 10060 12080
1,2 2,4 6,03,6 7,24,8
10
20
30
40
50
60
HmL / 1'm3/ h
Q
70
JET
Applications
- Pumping and distribution of water in domestic systems- Booster systems- Washing systems, irrigation
Usage limitations
Non-aggressive and non-explosiveclean liquids free of suspended solidparticles and fibres- Maximum liquid temperature 50° C- Maximum operating pressure 10 bar
Technical data
Flow : Q max. 8 m3/hHead : H max. 80 m
CAST IRON SELF-PRIMINGPUMPS
20 60 14080 120
1,2 3,6 8,44,8 7,2
10
20
30
40
50
60
HmL / 1'm3/ h
Q
80
MULTINOX-A
70
40
2,4
100
6
160
9,6
Options
- automatic start and stop device- version supplied with cables
10
Surface Pumps
JETINOX
Applications
- Pumping and distribution of water in domestic systems used on a continuous or intermittent basis- Booster systems- Washing systems, garden irrigation, fountains
Usage limitations
- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 50° C- Maximum operating pressure 6 bar
Technical data
Flow : Q max. 5 m3/hHead : H max. 50 m
SELF-PRIMINGSTAINLESS STEEL PUMPS
20 40 10060 12080
1,2 2,4 6,03,6 7,24,8
10
20
30
40
50
60
HmL / 1'm3/ h
Q
70
NRM
Applications
- Air conditioning and heating systems- Pumping of water from lakes, watercourses, wells- Overhead or surface irrigation- Industrial application.- Boosting and firefighting systems.
Usage limitations
- Type of liquid: non-aggressive, non-explosive, free from solid particles and fibres.- Hot water for heating- Coolants- Environmental temp.: max 40° C- Temperature of pumped liquid:- 10° C + 130° C- Maximum operating pressure: 10 bar
Technical data
Flow : Q max. 600 m3/hHead : H max. 95 m
CLOSE-COUPLEDCENTRIFUGAL PUMPS(2 - 4 Poles)
100 200 400 1000 2000 4000 10000(L/min)Qm3/h 6 12 24 60 120 240 600
Hm568
10
20
30
40
50
60
80
100120
NRB
Applications
- Aqueducts- Irrigation- Water distribution- Industrial applications
Technical data
Flow : Q max. 330 m3/hHead : H max. 95 m
CENTRIFUGAL PUMPSWITH RIGID COUPLING
400200100502010656
8
10
20
30
40
60
80
100
125
Q (m3/h)
H (m)
Options
- automatic start and stop device- version supplied with cable and plug
Usage limitations
- Type of liquid: non-aggressive, non-explosive, free from solid particles and fibres.- Hot water for heating- Coolants- Environmental temp.: max 40° C- Temperature of pumped liquid:- -10° C + 130° C- Maximum operating pressure: 10 bar
11
Surface Pumps
CM
Applications
- Pumping from wells for irrigation- Booster systems- Washing systems, garden irrigation, fountains
Usage limitations
- Type of liquid: non-abrasive clear or slightly cloudy water- Maximum liquid temperature 90° C (model CM 90/22 50° C)- Maximum operating pressure:8 bar
Technical data
Flow : Q max. 8 m3/hHead : H max. 51 m
HORIZONTAL SINGLE STAGEAND TWO STAGESCENTRIFUGAL PUMPS
30 60 15090 180120
1,8 3,6 9,05,4 10,87,2
10
20
30
40
50
60
HmL / 1'm3/ h
Q
70
CB
Applications
- Booster systems- Small-scale irrigation- Non aggressive liquids transfer- Washing systems
Technical data
Flow : Q max. 12 m3/hHead : H max. 76 m
Usage limitations
- Type of liquid:non-abrasive clear or slightly cloudy water- Maximum liquid temperature: 40° C for models 0,55 - 0,75 Kw 90° C for models 1,1 - 4,0 Kw- Maximum operating pressure: 10 bar
SINGLE STAGE AND TWO STAGESCENTRIFUGAL PUMPS
40 80 200120 240160
2,4 4,8 11,67,2 14,49,6
10
20
30
40
50
60
HmL / 1'm3/ h
Q
80
EP
Applications
- Small-scale booster systems- Domestic autoclaves- Small-scale irrigation- Washing systems
Technical data
Flow : Q max. 3,6 m3/hHead : H max. 60 m
Usage limitations
- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 70° C- Maximum operating pressure 6.5 bar
PERIPHERAL PUMPS
10 20 5030 6040
0,6 1,2 3,01,8 3,62,4
10
20
30
40
50
60
HmL / 1'm3/ h
Q
70
12
Pumps for open and drilled wells
DOMINATOR 5
Applications
- Pumping of water from traditional wells- Domestic tank installations for boosting domestic drinking water systems- Small-scale automatic systems for garden irrigation- Surface irrigation
Usage limitations
- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 40° C- Maximum submersion under the water level 20 m
Technical data
Flow : Q max. 8 m3/hHead : H max. 75 m
PRATIKA
Applications
- Pumping of water from traditional wells- Domestic tank installations for boosting domestic drinking water systems- Small-scale automatic systems for garden irrigation- Surface irrigation
Usage limitations
- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 40° C- Maximum submersion under the water level 10 m
Technical data
Flow : Q max. 6 m3/hHead : H max. 46 m
DOMINATOR 4
Applications
- Pumping of water from traditional wells- Domestic tank installations for boosting domestic drinking water systems.- Small-scale automatic systems for garden irrigation- Surface irrigation
Technical data
Flow : Q max. 5 m3/hHead : H max. 57 m
Usage limitations
- Type of liquid: clean water with no Suspended solids or abrasive material- Maximum liquid temperature 40° C- Maximum submersion under the water level 20 m
5” SUBMERSIBLE MULTISTAGECENTRIFUGAL PUMPFOR CLEAN WATER
STAINLESS STEEL MULTISTAGECENTRIFUGAL SUBMERSIBLEPUMPS FOR CLEAR WATER
4” SUBMERSIBLE MULTISTAGECENTRIFUGAL PUMPFOR CLEAN WATER
20 40 10060 80
1,2 2,4 63,6 4,8
10
20
30
40
50
60
HmL / 1'm3/ h
Q
70
20 40 10060 12080
1,2 2,4 63,6 7,24,8
10
20
30
40
50
60
HmL / 1'm3/ h
Q
70
140
8,4
160
9,6
30
20 40 12060
1,2 2,4 7,24,8
10
20
40
50
HmL / 1'm3/ h
Q 80
3,6 6
100
13
Pumps for openand drilled wells
SA
Applications
- Civil and industrial supply systems- Overhead or surface irrigation- Boosting- Firefighting- Various civil and industrial applications- Mains water supply systems
Technical data
Flow : Q max. 66 m3/hHead : H max. 270 m
Usage limitations
- Type of liquid: clean non-aggressive, non-explosive, free of solids- Maximum liquid temperature 30° C
6" MULTISTAGE SUBMERSIBLEPUMPS
250
150 300 750450 1100600
9 18 4527 6636
50
100
150
200
300
HmL / 1'm3/ h
Q
350
900
54
1050
63
SCM 4 HF
Applications
- Pumping of water from drilled wells- Automatic systems for garden irrigation- Surface irrigation for agricultural use- Drinking water systems- Pumping and supply of stored deposits or of booster autoclaves for civil and industrial systems
Technical data
Flow : Q max. 21 m3/hHead : H max. 100 m
Usage limitations
- Type of liquid: clean non-aggressive, non-explosive, free of solids- Maximum liquid temperature 30° C
4" MULTISTAGE CENTRIFUGALSUBMERSIBLE PUMPS
120
100
80
60
40
20
50 100 150 200 250 300 350 400L / 1'm3/ h
Q
Hm
3 6 9 12 15 18 21 24
SCM 4 PLUS
Applications
- Pumping of water from drilled wells- Automatic systems for garden irrigation- Surface irrigation for agricultural use- Drinking water systems- Pumping and supply of stored deposits or of booster autoclaves for civil and industrial systems
Technical data
Flow : Q max. 15 m3/hHead : H max. 300 m
Usage limitations
- Type of liquid: clean non-aggressive, non-explosive, free of solids- Maximum liquid temperature 30° C
4" MULTISTAGE CENTRIFUGALSUBMERSIBLE PUMPS
50 100 250150 300200
3 6 159 1812
50
100
350
200
250
300
HmL / 1'm3/ h
Q
150
Options
- 4” submersible motors (NEMA spec with electric cable)- 4” pump-end
Options
- 4” submersible motors (NEMA spec with electric cable)- 4” pump-end
Options
- 6” submersible motors (NEMA spec with electric cable)- 6” pump-end
14
Sump sewage and effluent pumps
SIMO
Applications
- Drainage of seepage water, pumping of rain water from grating or drain- Emptying of water deposits, collection tanks and wells
Usage limitations
- Type of liquid: clear water- Maximum liquid temperature 50° C- Maximum submersion under the water level 2 m- Minimum drainage level 3 mm- Minimum priming level 20 mm
Technical data
Flow : Q max. 3,3 m3/hHead : H max. 6 m
DPC
Applications
- Drainage of seepage water, pumping of rain water from grating or drain- Emptying of water deposits, collection tanks and wells
Usage limitations
- Type of liquid: clear water- Maximum liquid temperature 40° C- Maximum submersion under the water level 7 m- Minimum drainage level 3 mm (man.), 30 mm (aut.)- Free clearance of solids 5 mm
Technical data
Flow : Q max. 10 m3/hHead : H max. 10 m
DP
Applications
- Drainage of seepage water, pumping of rain water from a grating or drain- Draining of environments, tanks and wells
Technical data
Flow : Q max. 9 m3/hHead : H max. 7 m
Usage limitations
- Type of liquid: clear water- Maximum liquid temperature 40° C- Maximum submersion under the water level 7 m- Minimum drainage level 10 mm- Free clearance of solids 6 mm
SUBMERSIBLE PUMPFOR DRAINING CLEAR WATER
SUBMERSIBLE PUMPFOR DRAINING CLEAR WATER
SUBMERSIBLE PUMPFOR DRAINING CLEAR WATER
30 60 15090 180120
1,8 3,6 9,05,4 10,87,2
1
2
3
4
5
6
HmL / 1'm3/ h
Q
8
10 20 5030 6040
0,6 1,2 31,8 3,62,4
1
2
3
4
5
6
HmL / 1'm3/ h
Q
8
30 60 15090 180120
1,8 3,6 9,05,4 10,87,2
2
4
6
8
10
12
HmL / 1'm3/ h
Q
14
15
Sump sewageand effluent pumps
DRENOX DPV OMNIA
Applications
- Drainage of seepage water, pumping of rain water, from a grating or drain, pumping of domestic waste water, drainage of environments, bathing and swimming pools, industrial applications- Fountains and water features- Surface irrigation
Usage limitations
- Type of liquid: partially effluent and dirty clear water, non-aggressive liquids- Maximum liquid temperature 40° C- Maximum submersion under the water level 7m- Minimum drainage level: from 3mm to 35 mm- Free clearance of solids: from 3 mm to 6 mm
Technical data
Flow : Q max. 18 m3/hHead : H max. 11 m
Applications
- Drainage of domestic dirty water- Draining of environments, tanks and wells
Technical data
Flow : Q max. 7 m3/hHead : H max. 6,5 m
Usage limitations
- Type of liquid: dirty water with solids- Maximum liquid temperature 40° C- Maximum submersion under the water level 7 m- Minimum drainage level 35 mm- Free clearance of solids 25 mm
Applications
- Pumping of domestic waste water, draining of environments, bathing and swimming pools, industrial applications- Fountains and water features- Surface irrigation
Technical data
Flow : Q max. 12 m3/hHead : H max. 8 m
Usage limitations
- Type of liquid: waste water with solids- Maximum liquid temperature 40° C- Maximum submersion under the water level 7 m- Minimum drainage level 35 mm- Free clearance of solids 20 mm
SUBMERSIBLE PUMPSFOR DRAINING CLEAR WATER
SUBMERSIBLE PUMPFOR DRAINING DIRTY WATER
SUBMERSIBLE SUMP PUMPSFOR DIRTY WATER
50 100 250150 300200
3 6 159 1812
2
4
6
8
10
12
HmL / 1'm3/ h
Q20 40 10060 12080
1,2 2,4 63,6 7,24,8
1
2
3
4
5
6
HmL / 1'm3/ h
Q
7
40 80 200120 240160
2,4 4,8 11,67,2 14,49,6
1
2
3
4
5
6
HmL / 1'm3/ h
Q
8
16
Sump sewage and effluent pumps
MINIVORT P
Applications
- Pumping and draining effluent; civil and industrial sewage with suspended solids- Draining of cesspits, cesspools, handling of effluent- Pumping stations with one or more pumps for civil and industrial plants
Usage limitations
- Type of liquid: waste water and sewage- Maximum liquid temperature 40° C- Maximum submersion under the water level 7 m- Minimum drainage level 45 mm (manual version)- Free clearance of solids 52 mm
Technical data
Flow : Q max. 36 m3/hHead : H max. 13 m
MINIVORT PP
Applications
- Pumping and draining effluent; civil and industrial sewage with suspended solids- Draining of cesspits, cesspools, handling of effluent- Pumping stations with one or more pumps for civil and industrial plants- On request, connecting foot to make installations and maintenance easier
Usage limitations
- Type of liquid: waste water and sewage- Maximum liquid temperature 40° C- Maximum submersion under the water level 7 m- Minimum drainage level 72 mm (manual version)- Free clearance of solids 58 mm
Technical data
Flow : Q max. 50 m3/hHead : H max. 11 m
PRIOX
Applications
- All applications of pumping and draining effluent, civil and industrial sewage with suspended solids- Pumping stations with one or more pumps for civil and industrial plants
Technical data
Flow : Q max. 39 m3/hHead : H max. 18 m
Usage limitations
- Type of liquid: waste water and sewage with solids- Maximum liquid temperature 40° C- Maximun submersion under the water level 7 m- Minimum drainage level 60 mm (manual version)- Free clearance of solids: max 50mm
SUBMERSIBLE SEWAGE PUMPSWITH VORTEX IMPELLER
SUBMERSIBLE SEWAGE PUMPSWITH VORTEX IMPELLER
SUBMERSIBLE EFFLUENT VORTEXPUMPS FOR DIRTY WATER
24
100 200 600300 700400
6 12 3618 4230
4
8
12
16
20
24
HmL / 1'm3/ h
Q 500
9
100 200 600300 700400
6 12 3618 4230
3
6
12
15
HmL / 1'm3/ h
Q 500
24
200 400 800
12 24 4836
2
4
6
8
10
12
HmL / 1'm3/ h
Q 600 1000
60
17
Sump sewageand effluent pumps
FGT FGV FGC
Applications
- Contamined water- Sewage with fibres- Industrial waste and animal slurry chemically compatible with the pump construction materials
Usage limitations
- Max temperature of pumped liquid: 40° C- Max immersion depth: 20 m- PH: between 6-11- Running positioning: only vertical- Outlet nominal diameter: 2” gas- For continuous operation, within the allowed use limits, the submersible pump must be submerged for 2/3 of its height, at least.- Suitable for fixed installation, with rapid coupling device or more portable applications suspended or rested.- Free passage: 5 mm
Technical data
Flow : Q max. 20 m3/hHead : H max. 25 m
Applications
- Sewage with suspended solids including long fibres.- For liquid mixing in stock tanks, for industrial waste and animal slurry with solids in suspension
Technical data
Flow : Q max. 160 m3/hHead : H max. 40 m
Usage limitations
- Max temperature of pumped liquid: 40° C- Max immersion depth: 20 m- PH: between 6-11- Running positioning: only vertical- For continuous operation, within the allowed use limits, the submersible pump must be submerged for 2/3 of its height, at least.- Suitable for fixed installation with coupling foot, guide rails and chain, or more portable applications suspended or rested.
Applications
- Sewage, effluent and rainwaters without long fibres- Animal slurry, industrial water with solids in suspension of max diameter of 108 mm according to pumps size
Technical data
Flow : Q max. 460 m3/hHead : H max. 34 m
Usage limitations
- Max temperature of pumped liquid: 40° C- Max immersion depth: 20 m- PH: between 6-11- Running positioning: only vertical- Outlet nominal diameter: DN150- For continuous operation, within the allowed use limits, the submersible pump must be submerged for 2/3 of its height, at least.- Suitable for fixed installation with coupling foot, guide rails and chain, or more portable applications suspended or rested.- Free passage: 95-108 mm.
SUBMERSIBLE PUMPSFOR WASTE WATERCUTTER PLATE IMPELLER
SUBMERSIBLE PUMPSFOR WASTE WATERVORTEX IMPELLER
SUBMERSIBLE PUMPSFOR WASTE WATERSINGLE CHANNEL IMPELLER
50 100 300 1000 3000 10000L / 1'm3/ h
Q3 6 18 60 180 600
10
20
30
40
Hm
1000 3000 1000060 180 600
10
20
30
40
HmL / 1'm3/ h
QL / 1'm3/ h
Q 50 100 300 5003 6 18 30
10
20
30
Hm
18
Booster Systems
BOOSTER SYSTEMWITH CAST IRON PUMPAND 24 Lt STEEL TANK
Technical data
Flow : max. 6 m3/hHead : max. 60 m
BOOSTER SYSTEMSWITH 2 HORIZONTALOR VERTICAL PUMPS
Technical data
Flow : max. 420 m3/hHead : max. 120 m
BOOSTER SYSTEMSWITH 2 HORIZONTALOR VERTICAL PUMPS
Technical data
Flow : max. 630 m3/hHead : max. 120 m
VARIABLE SPEEDPRESSURE BOOSTERSYSTEMS WITH 2 PUMPSAND 2 VSD INVERTERS
Technical data
Flow : max. 30 m3/hHead : max. 106 m
VARIABLE SPEED PRESSUREBOOSTER SYSTEMSWITH 2-3-4 VERTICAL PUMPS
Technical data
Flow : max. 288 m3/hHead : max. 120 m
UNI 9490 AND 10779 FIREFIGHTING SYSTEMSWITH ELECTRIC AND ENGINEDRIVEN PUMPS
Technical data
Flow : max. 630 m3/hHead : max. 110 m
PRESSOMAT SENSORMAT
VSD 20 FREQUENCY CHANGER UNIMAT - UNISTOP
WATERPRESS
19
Applications
- For fountains, water features, waterfalls in water gardens
Technical data
Flow : max. 18 m3/hHead : max. 11 m
Applications
- Manufacture of delivery assemblies- For farm diesel transfer- Farm machines- Small pumping stations
Technical data
Flow : max. 3,6 m3/hHead : max. 40 m
Applications
- Fire Fighting- Tank filling- Water transfer- Hydrants- Irrigation
Technical data
Flow : max. 42 m3/hHead : max. 100 m
VSDELECTRIC PANELS
VSD is a device which is able tomodulate the speed of a pump with thepurpose to maintain constant pressure.
VSD1 / VSD1 basic:for three phase pumps (3x230 V)and single phase (230 V) power supply
VSD 3 : for three phase pumps (3x400 V)and three-phase (400 V) power supply
In compliance withEuropean Directive 97/23/EC
Electric starter for the controland protection of single phaseand three phase pumps.
VARIABLE SPEED DRIVE
- steel- stainless steel- composite material
Capacity: from 2 to 1022 L
EXPANSIONTANKS
VERSAILLES PGA BLAZESUBMERSIBLE PUMPS FORFOUNTAINS AND WATERFALLS
SPECIAL SELF-PRIMING LIQUID RINGPUMPS FOR DIESEL TRANSFER
SINGLE AND TWIN IMPELLER ENGINEDRIVEN PUMPS
BELGIUMPentair WaterIndustriepark Wolfstee,Toekomstlaan 30B-2200 HERENTALSTel. +32.14.25.99.11Fax. +32.14.25.99.75www.pentairwater.com
RUSSIAPentair Pumps4 Luchevoy ProsekExhibition Centre “Sokolniki”Pav. 5, Off. 30 - MoscowTel.+7-095-913 90 22, 956 55 61Fax +7-095-234 23 50www.nocchi.ru
GERMANYPentair WaterWiesenstraße 6Industriegebiet NordD-64347 GriesheimTel. +49615584170Fax +496155841799
REPUBLIC OF SOUTH AFRICAPentair WaterP.O. Box 11325, Selcourt 1567,15 Miller Road,Nuffield, Springs - GautengaTel. +27.11.818.5818Fax +27.11.818.3710
140, avenue Roland Garros78532 BUC CEDEXTel. +33.(0)1.39.24.15.00Fax. +33.(0)1.39.56.03.90www.pentairwater.com
Pentair Water
FRANCEPentair PumpsBP 92 Vedene - 84965LE PONTET Cedex - AVIGNONTel. 04.90.480.880Fax 04.90.480.888www.nocchi.it
Pentair WaterVia Brughiera 1 - 20010PREGNANA MILANESE (MI)Tel. +39.02.93.27.111Fax. +39.02.93.27.1154www.pentairwater.com
ITALYPentair PumpsVia Masaccio, 1356010 Lugnano (Pisa)Tel. +39.050.71.61.11Fax. +39.050.70.31.37www.nocchi.it
ww
w.f
ranc
ofer
rucc
i.com
UNITED KINGDOMPentair Water FiltrationDaimler Drive, Cowpen LaneIndustrial EstateBillingham - Cleveland, TS23 4DJTel. +44 (0)1 642 370 616Fax +44 (0)1.642.564.708
UNITED ARAB EMIRATESPentair Water Middle EastAl Diyaffa Center, M Floor Office 104-105P.O. Box 24670Dubai, U.A.E.Tel. +971.43.45.50.74Fax. +971.43.45.51.04www.pentairwater.com
GB
- 1°
ED
. 012
006
- CO
D. N
V26
0P80
0