Centric A NEW ADVANCED MODULAR UPS FROM 25KW/KVA CENTRIC April 2015 www.gamatronic.com GAMATRONIC ELECTRONIC INDUSTRIES LTD. Headquarters and Factory 17 Hartom St. POB 45029, Jerusalem 91450, Israel Tel: +972-2-5888222 Fax: +972-2-5828875 e-mail: [email protected] Gamatronic UK Ltd. 15 Chester Road, Colmworth Business Park, Eaton Socon, Cambridgeshire, PE19 8YT, United Kingdom Tel: +44 (0)1480 479889/ 472665 Fax: +44(0)1480 407865 e-mail: [email protected] CENTRIC: Technical specifications for the system controller * All specifications are subject to change without advance notice. Display LCD flat panel, touch-sensitive Other indicators Audible alarm Analog input channels 4 input dry contacts (N.O. / N.C.) Real-time clock (RTC) Yes, with backup Power meter kVA, kW, PF Volt-free outputs (dry contacts) 6 outputs, rated 48 V / 1 A Output dry contacts Ac failure Dc failure UPS module(s) failure Load on bypass Battery test failure Over/under temperature Overload (Each system alarm type can be routed to the dry contact of your choice.) Communication ports Serial, Ethernet, USB Communication protocols RS232, RS485, TCP/IP, SNMP, Modbus Communications with system modules Serial, isolated Events log 500 events System operation without controller Unchanged On-screen parameters Load bar-graph 3-phase voltages 3-phase currents Battery voltage Status of each UPS module Static-switch parameters and status Battery sensor temperature RTC operation without power Indefinitely Power requirements 3 × 400 Vac and 405 Vdc Remote indication panel capability Yes 1 10

Upload: paulo-chong

Post on 12-Apr-2017

160 views

Category:

Engineering


1 download

TRANSCRIPT

CentricA new AdvAnCed ModulAr uPS

froM 25kw/kvA

CENTRIC

April 2015

www.gamatronic.com

GAMATronIC eleCTronIC InduSTrIeS lTd.

Headquarters and factory 17 Hartom St. POB 45029, Jerusalem 91450, Israel Tel: +972-2-5888222 Fax: +972-2-5828875 e-mail: [email protected]

Gamatronic uk ltd. 15 Chester Road, Colmworth Business Park, Eaton Socon, Cambridgeshire, PE19 8YT, United Kingdom Tel: +44 (0)1480 479889/ 472665 Fax: +44(0)1480 407865 e-mail: [email protected]

CenTrIC:Technical specifications for the system controller

* All specifications are subject to change without advance notice.

Display LCD flat panel, touch-sensitive

Other indicators Audible alarm

Analog input channels 4 input dry contacts (N.O. / N.C.)

Real-time clock (RTC) Yes, with backup

Power meter kVA, kW, PF

Volt-free outputs (dry contacts) 6 outputs, rated 48 V / 1 A

Output dry contacts

Ac failureDc failureUPS module(s) failureLoad on bypassBattery test failureOver/under temperatureOverload(Each system alarm type can be routed to the dry contact of your choice.)

Communication ports Serial, Ethernet, USB

Communication protocols RS232, RS485, TCP/IP, SNMP, Modbus

Communications with system modules Serial, isolated

Events log 500 events

System operation without controller Unchanged

On-screen parameters

Load bar-graph3-phase voltages3-phase currentsBattery voltageStatus of each UPS moduleStatic-switch parameters and statusBattery sensor temperature

RTC operation without power Indefinitely

Power requirements 3 × 400 Vac and 405 Vdc

Remote indication panel capability Yes

110

CentricThe new Centric uPS from 25 to 200 kw/kvAGamatronic is proud to present the Centric, an innovative UPS available in 10 configurations (25, 50, 75, 100, 125 , 150, 175, 200 kW/kVA).

For a complete IT solution we offer 2 models of the Centric with internal batteries as a 25kVA and a 50kVA unit.

The Centric provides reliable, clean, regulated ac power at an attractive price.

For users with greater power requirements, the Centric can be operated in up to four units in parallel.

CENTRIC

The Centric’s double conversion topology provides high quality power regulation in accordance with IEC 62040 VFI-SS-111 and ac-ac efficiency up to 96%.

The Centric battery is true online as per IEC 62040, guaranteeing instant availability of backup power in the event of mains failure and provides high unique dc –ac efficiency of up to 98%.

The Centric’s vertical and horizontal modularity reduce the down time thus providing a fault tolerant power source to critical load and application.

The Centric’s reliability flexibility, intelligent features and design make it a great choice for your data center.

Standard features• Advanced colorful LCD touch screen.

• True on-line battery.

• Up to 96% efficiency.

• High power output & small footprint.

• Light weight.

Additional features are available:• Manual maintenance bypass switch.

• Email notification of system alarms.

• Modbus / RS232 / RS485 communication protocols.

• Automatic, orderly shutdown of connected computers during a power blackout.

Power usage effectiveness (Pue) efficiency

Centric is an ideal efficient UPS for Tier 3 and 4 data centers with a low load. The Centric can achieve 96% efficiency in a load between 20% to 60%.

2n+1 (Tier 4) Application

25% LOAD CENTRIC 2 x 200 kVA/kW

25% LOAD CENTRIC 2 x 200 kVA/kW

100% IT LOAD

efficiency vs. load

2 3

The PC based centric controller enhances data centre management systems with its unique abilities:

• Built in flexible connectivity

• Intelligent interface

• Fail safe (non critical for UPS operation)

• Hot swappable

Additional features include:

• RS232

• Modbus RS485

• Modbus TCP/IP

• USB

• SNMP

• Web interface

• Configurable web interface

• Unlimited server’s shutdown

• Unlimited email notifications

• Smart and fault proof diagnostic events history

• Multi language interface

foot Print Power: 49w / cm2 ׀ Power density: 0.4w / cm3

Centric Power density

120 cm

76 cm54 cm

76 cm

120 cm

162 cm4 5

Centric MTTr

Conventional or Stand Alone uPS MTTr:• Diagnostics – can take hours to days

• Required Parts – can take days or even weeks to arrive. Immediate spare parts are very expensive to obtain

• Skills & qualifications – special expensive experts are required

• Testing – it is usually extremely difficult to run 100% required testing in the field

Centric modular uPS - MTTr is merely a few minutes: • Diagnostics – immediate

• Required Parts – immediate spare parts are cheap

• Skills & qualifications – no need for expensive experts

• Testing - covers all UPS functions

Vertical modularity in basic unit is 25kW/kVA per power module; the vertical stack is scalable to up to 8 power modules (200kW).

Horizontal modularity of basic unit is up to 200kW, the horizontal scalability is up to 5 units (1000kW).

Power usage effectiveness (Pue) efficiency

front view

Stand alone

modular

The Centric modular uPS6 7

* All specifications are subject to change without advance notice.

CenTrIC 3x400 vac uPS: system specifications

Vertical and Horizontal redundancy with decentralized or centralized redundant battery

SolutionsTopology Modular, double-conversion, VFI, on-line battery

Operation Continuous

Input

Voltage (V) 3x400 (4 wires + Gnd)

Voltage range (%)-20 / +15 (360 ~ 460 Vac: full power; 320 ~ 360 Vac: derated 20 %)

Current (A) 3 × 42 per module – no inrush current at startup

Frequency (Hz) 47 – 63

Power walk-in (sec) 1 ~ 30 in 1 sec increments

Power factor correction >0.99

THDI (%) <3

Inrush current None

output

Rated Power (kVA/kW) 25/25 ~ 200/200

Nominal frequency (Hz) 50/60

Frequency tracking range (Hz) ±(0.5, 1, 2, 3, 4), selectable

Frequency tracking slew rate (Hz/sec) 1

Frequency (in free-running mode) (Hz) 50/60 ±0.1 %

Nominal voltage (Vac) 3x400 (4 wires + Gnd)

Static voltage regulation (%) ±1

Regulation for 100 % unbalanced load (%) ±1

Dynamic response to 100 % load step (%) ±2

Overload withstand Inverter mode 110 % : 10 min, 125 % : 60 s, 150 % : 30 s

Bypass mode 125 % : 10 min, 1000 % : 1 cycle

Waveform Sinusoidal

THD (%) Linear load: <2; non-linear load: <6

Load CF (max) 6:1

Power factor Any

Ac-Ac efficiency (nominal) (%) Up to 96

Batteries

Dc-link voltage (Vdc) 300 ~ 405 (405 floating, accuracy to ±1 %)

Quantity 60 × 12 Vdc

Type Sealed, lead-acid. Lithium-ion batteries also supported.

General

Maximum power dissipation (Po=25 kW) N*1041 W (N*3552 BTU/h), where N = # modules

Ambient temperature (°C) -10 to +40 (operating), -20 to +60 (storage)

Relative humidity (%) 95 maximum, non-condensing

Altitude (m) 1500 without derating

Enclosure IP20

Cooling system Multi-fan with speed control (forced)

Design & manufacturing standards

Safety IEC 62040-1

EMC IEC 62040-2

Design classification IEC 62040-3

Low magnetic field radiation EMF as per ICNIRP

dimensions

UPS model 50 kW 100 kW 200 kW

# of power modules 1 2 2 3 4 4 5 6 7 8

Power output (kW/kVA) 25 50 50 75 100 100 125 150 175 200

Height (mm) (w/o wheels) 665 932 1200

width (mm) 540

depth (mm) 757

weight (kg) w/o batt. box 72.2 92.0 102.4 122.2 142 149.3 169.1 188.9 208.7 228.5

dimensions (H x w x d, mm) & weight of batt. box for 50 kw system 985 x 540 x 743, 66 kg

Up to 175kW Vertical & Horizontal

Redundancy

Up to 200kW Horizontal

Redundancy

Up to 350kWVertical

Redundancy

Up to 75kW Vertical & Horizontal Redundancy

Up to 100kW Horizontal

Redundancy

Up to 150kW VerticalRedundancy

Up to 150kW Vertical & Horizontal

Redundancy

Up to 200kW Horizontal

Redundancy

Up to 225kWVertical

Redundancy

Up to 225kW Vertical & Horizontal

Redundancy

Up to 300kW Horizontal

Redundancy

Up to 300kW VerticalRedundancy

Up to 350kW Vertical & Horizontal

Redundancy

Up to 400kW Horizontal

Redundancy

Up to 525kWVertical

Redundancy

Up to 525kW Vertical & Horizontal

Redundancy

Up to 600kW Horizontal

Redundancy

Up to 700kWVertical

Redundancy

Up to 700kW Vertical & Horizontal

Redundancy

Up to 800kW Horizontal

Redundancy

Up to 875kWVertical

Redundancy