nimbus brochure - jan15 - fike | fire, explosion and · pdf file ·...

7
3 T w Fike Safety 31 Springvale In T: +44 (0) 1633 www.fikesa y Technolog ndustrial Estate 3 865 558 E: fs afetytechno gy Ltd e, Cwmbran NP s[email protected]m ology.com P44 5BD UK m

Upload: letuyen

Post on 06-Mar-2018

220 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Nimbus brochure - Jan15 - Fike | Fire, Explosion and · PDF file · 2016-10-04• Compliance with BS5839/EN54 service requirements ... Microsoft Word - Nimbus brochure - Jan15.docx

 

 

 

 

     

3Tw

Fike Safety 31 Springvale InT: +44 (0) 1633www.fikesa

y Technologndustrial Estate3 865 558 ‐ E: fsafetytechno

gy Ltd e, Cwmbran [email protected] 

P44 5BD UK m 

Page 2: Nimbus brochure - Jan15 - Fike | Fire, Explosion and · PDF file · 2016-10-04• Compliance with BS5839/EN54 service requirements ... Microsoft Word - Nimbus brochure - Jan15.docx

 

 

IntrodNimbusGatewaEvent n The primservicinsystem/ Nimbusmaintai

 

 

The flexfire alarexisting

 

uction s is a Cloud ay. Data is snotifications

mary applicng, mainten/s. 

s is the ideain a life time

xible web brm activity tg desktop ap

based datatored in a ss are sent vi

cation of Nimance, testin

al manageme electronic

rowser Nimthrough a cpplications 

base, receivecure databia Email and

mbus is to lng, perform

ment tool forc log of thei

mbus interfaommon prewith standa

 

ving data frbase and acd or SMS M

og, manageance and d

r service, buir fire alarm

ace providesesentation fard Copy, C

rom Fire Alaccessed via essaging. 

e and adminay to day u

uilding & esm systems. 

s you with cformat. DatSV, Excel, P

arm systemsa standard 

nistrate these of the co

state manag

complete vita can be intDF & Print t

s via a GPRSweb brows

e commissioonnected fir

gers who ne

isibility of ategrated wtools. 

S ser. 

oning, re alarm 

eed to 

 

ll your ith your 

Page 3: Nimbus brochure - Jan15 - Fike | Fire, Explosion and · PDF file · 2016-10-04• Compliance with BS5839/EN54 service requirements ... Microsoft Word - Nimbus brochure - Jan15.docx

 

 

Any nuManagibe timesystemsmaintaiyour FirplatformFire Ala  

CompaNimbusthrough(ASCII). Alarm csupport 

 

 Non InThe GPRcommufunction

 

Simple

  

umber of sying any nume consumings are spreadined by diffre Alarm sysm managemarm through

atibility: s is compatih intelligentThe amouncontrol systets both stan

vasive:  RS Gatewayunications onality is not

e to Install:

ystems: mber of dispg and proned over a largerent compstems activment tool dehout its use 

ible with mot 3rd party cnt, type andems and thnd‐alone an

y connectioor printer pot affected. 

: RequiringtelephonGPRS GatcommunAlarm sy 

parate Fire Ae to errors, ge area andpanies. Nimity through etailing elecand life. 

ost analoguommunicatd complexitye connectiod networke

n is a non inort. The Fire

g no physicane lines or cteway provications patstem and N

Alarm systeespecially ifd serviced &bus central a single croctronic histo

ue addressations protocy of data dion method. ed Fire Alar

nvasive adde Alarm syst

al connectiolients IP nevides the ideth betweenNimbus. 

ems can f the & ises all oss ory of the 

ble Fire Alacol (BIT) or ffer across The GPRS Gms. 

d‐on to the tem 

on to twork the eal n the Fire 

rm control through thethe variousGateway an

Fire Alarm c

panels eithe printer pos types of Find Nimbus 

 

control pan

her ort re 

nel 

Page 4: Nimbus brochure - Jan15 - Fike | Fire, Explosion and · PDF file · 2016-10-04• Compliance with BS5839/EN54 service requirements ... Microsoft Word - Nimbus brochure - Jan15.docx

 

 

Secure: 

 

Data is stored and served from LAN Control Systems hosted secure server. Robust technology with instant automatic failover and redundant SAN storage provide a 99.99% availability. Frequent backups of data are made automatically to two differently located servers.  

 

Proof of Testing: Producing reports based on Fire Alarm testing has always been challenging. Service & maintenance companies have different methods of testing and producing evidence of what has been tested; engineer hand written dockets, print‐outs from control panels, site drawings with ticks or highlights against each device, coloured stickers attached to each device and scanned bar‐code stickers.  These methods are prone to inaccuracy and don’t necessarily provide conclusive evidence that particular testing has been carried out. Nimbus records the actual Fire Alarm control panel activity, recording specific details of device status and identity information. 

 

Infinite Log: Many Fire Alarm control panels have a limited internal memory to log activity. It is not 

unusual for a Fire Alarm system to have more detection devices and manual call points than the internal memory can record collectively. Fire Alarm control panel printers are temperamental, prone to jamming and running out of paper. Print‐outs are not easy to read, provide limited information and difficult to store, archive and recall. Nimbus logging is infinite, enabling reports to be generated at any time based on flexible search criteria.  

 

 Accessible: Nimbus is accessible from any Internet connected web browser enabled device.  

Page 5: Nimbus brochure - Jan15 - Fike | Fire, Explosion and · PDF file · 2016-10-04• Compliance with BS5839/EN54 service requirements ... Microsoft Word - Nimbus brochure - Jan15.docx

 

 

ReportGenera

   

NotificEvent nbased oevent ndescriptprocessSMS Menormal recipienof SMS Messag

 

SubscrA NimbManage

CorporEach su

  

 

 

ts: te reports b

generEventThe coallows

cations: notificationson the Fire Anotification tive labels ased immediessaging is sconsumer Snt’s cellularMessages tges to suit th

ibers: bus subscribers and/or U

syno

 

rate Logo: ubscriber ca

based on Wrate specifict, Panel, Looommon wes data expo

s can be senAlarm evendetails the and protocoately. sent via theSMS sendin network. Nto multiple he applicati

ber (ManageUsers. Userystems can otifications 

n personali

Weekly Testic reports baop, Device ab page inteort to; Copy,

nt by Email at types; Fireevent actiool data. Not

e Nimbus ceng path ensuNimbus can recipients. ion.  

er) managess are given be viewed, to receive.

se Nimbus 

 

ng, Servicinased on theand any proerface simpl, CSV, Excel

and/or SMSe, Pre Fire, Fon, the assotifications a

ellular netwuring immesimultaneoManagers c

s their ownvarying perwhich repo

with their o

 

UserpresNim

ng and Live air own searotocol paramlifies the ge, PDF or Pri

S MessagingFault, Isolatciated contre triggered

work portal bediate deliveously send vcan predefin

account byrmissions toorts can be g

own Corporrs created bsented withbus web pa

activity. Usech criteria; meter. neration ofnt tools. 

g to any numtion, Disablerol panel d and 

bypassing thery to the very large qne the cont

y administrao define whgenerated a

rate logo.  by the Mana the Corporage banner.

ers may alsoDate/Time,

f reports an

mber of recement etc. 

he 

uantities tent of SMS

ating additiohich Fire Alaand which 

ager will berate logo in. 

o , Mode, 

cipients Each 

 

onal rm 

e  the 

Page 6: Nimbus brochure - Jan15 - Fike | Fire, Explosion and · PDF file · 2016-10-04• Compliance with BS5839/EN54 service requirements ... Microsoft Word - Nimbus brochure - Jan15.docx

 

 

 Service Managers:  Utilising Nimbus as your Fire Alarm service management tool you can:  

• Proactive & Predictive service & maintenance o Check the system log before you attend site o Check activity/contamination/compensation levels o See the percentage of testing carried out in the annual 

service period • Offer clients higher service level agreements 

o Client transparency ‐ provide User access and notifications to Nimbus o Generate detailed reports  o Automate engineer response to system notifications 

• Check the reported problem remotely first o Evaluate first and plan accordingly 

• Paperless system accessible from most locations o Generate reports at any time from any location o Minimise administration costs 

• Single engineer testing/commissioning ‐ virtually real‐time descriptive test data providing confirmation to engineer whilst testing via SMS/Email/Web 

• Attach and Upload documents to the service record o Installation, Commissioning, Certification, Service and Maintenance 

documentation • Attach and Upload control panel configuration files 

o No more misplaced disks or USB memory sticks • Add comments to each device in the testing log • Measure engineer performance • Measure detection/system performance • Schedule service visits and receive pending email notification 

 

   

Page 7: Nimbus brochure - Jan15 - Fike | Fire, Explosion and · PDF file · 2016-10-04• Compliance with BS5839/EN54 service requirements ... Microsoft Word - Nimbus brochure - Jan15.docx

 

 

 Facilities & Estate Manager:  A new and creative way to manage and monitor your fire alarm systems Nimbus offers higher level of management than has previously been possible. 

• Have confidence that the Fire Alarm is maintained correctly • Monitor and measure contractor performance to get best value • Compliance with BS5839/EN54 service requirements • Compliance with Regulatory Reform (Fire Safety) Order 2005 maintenance 

requirements • Independent proof of testing  • Integrate different systems into one platform • Electronic total life history • Create an Asset log • Monitor the product life cycle • Integrate data to CAFM and Internal systems • Extend the life and functionality of existing systems 

 As a cloud based system Nimbus offers many advantages over conventional management systems 

• Reduce cost o Paying incrementally reduces capital expenditure  

• Reduced I.T. overhead o No specific internal hardware required  o No specific software required o Scalable o Future proof 

• Increase administration performance • Automated • Reduced carbon footprint  

o Less travelling o Less hardware/software/paper/consumables 

• Flexible o Accessible from anywhere o Share data with colleagues 

• Infinite Storage o Unlimited Log