new versaflow coriolis - honeywell2017 coriolis update 15 •twc9400 - high performance signal...

22
With Stable Two-phase Flow Measurement NEW VERSAFLOW CORIOLIS Steffen Baecker June 20, 2017 Honeywell Internal

Upload: others

Post on 15-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

With Stable Two-phase Flow MeasurementNEW VERSAFLOW CORIOLISSteffen Baecker

June 20, 2017

Honeywell Internal

Page 2: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

VersaFlow – Flow Technologies

• Volume flow measurement

• Conductive fluids only

- Water

- Chemicals

- Food & Beverage

• Slurries & pastes with solid content

• Abrasive products

Magnetic Flowmeters Coriolis Flowmeters

Ultrasonic Flowmeters Vortex Flowmeters

• Direct mass measurement

• Low flow & bulk flow measurement

- Oils

- Chemicals

- Custody transfer

• Multiple measurements

- Density

- Temperature

- Concentration

• Volume flow measurement

• Transit time based

• Pure liquids only

- Water

- Acids & Alkalies

- Refined Hydrocarbons

- Solid content < 5% & Gas content < 2%

• Volume flow measurement

• Conductive & non-conductive fluids

• Steam, Gases & Liquid flow

- Saturated & Superheated steam

- Gases – N2, O2, Air etc

- Liquids e,g DM Water

Page 3: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

Sizing Software

One for all VersaFlow products

• All new sizing Software

- Easy To Use

- Constant updates

- Sizing to print

- Hudge data base of

fluids and liquids

- All measurement principles

Vortex in next update

Page 4: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

© 2015 by Honeywell International Inc. All rights reserved.

• One device will measure- Mass flow

- Density

- Volume

- Temperature

- Mass or volume concentration

• Applications- Low flow to bulk flow measurement

- Fuel oils, Hydrocarbons, Chemicals

- Custody transfer applications

- High accuracy process applications

• Available in various tube MOCs- Stainless steel

- Hastelloy

- Titanium

- Tantalum

VersaFlow – Coriolis Mass Flow Meter

All measurements in Single Device

Coriolis 100

Coriolis 1000

Coriolis 200

Page 5: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

2017 Coriolis Update

4

• TWC9400

- High performance signal converter for all

applications

- Stable in multi-phase applications due to

Entrained Gas Management (EGM™)

- Highly developed diagnostic functions acc.

to NAMUR NE 107

- HART 7.4

• Coriolis 6000 and 200 Large line sizes

- High performance meter for process

industries

- Cryogenic, high temperature and high

pressure options

- Supreme liquid and gas performance

- High Pressure Solution

- Heating Jacket

- Up to 8” (C6000) and 14” (C200) with up

to 16” process connection

All new electronics, sensors larger than ever

Honeywell Internal

Page 6: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

VersaFlow TWC 9400Product information

5

Advanced measurement capability and stability

provides added advantages for specifications

Measurement from 0 to 100 % gas entrainment

(Two-phase flow)

Flat-line accuracy of 0.1% for VFC200, 6000 and 1000

Titanium

Flat line accuracy of 0.05% for turndown 10:1 for VFC200

and 6000

Improved density measurement and stability

No “Start Up” issues with air entrainment

Improved pulse output for proving

Page 7: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

VFC100 + TWC9400

VFC6000 + TWC9400

VFC1000 + TWC9400

VFC200 + TWC9400

Entrained Gas Management in TWC9400Coriolis mass flowmeters with EGM

Page 8: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

• A change in these parameters can cause a

change in flow regimes

• Multiphase flow regimes have no sharp

boundaries

• Can change smoothly from one regime to

another

• Multiphase flow measurements can be

challenging

Mist

Bubble

Wave

Annular

Slug

Plug

Stratified

*Superficial velocity is the velocity that the (liquid or gas) phase would have, in case it was

the only phase flowing through the pipe.

Entrained Gas ManagementFlow regimes

Page 9: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

Pure gasWater

Entrained gas

Resonance

frequency

(in Hz)

100 150 200 250 300 350 400

Gain / dB

-60

-40

-20

0

20

40

60

80

Entrained Gas ManagementHow damping impacts density measurement

Page 10: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

Coriolis Flow Measurement TechnologyHow process conditions affects measurement without EGM capability

Conventional

drive

control

Startup

Page 11: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

Drive

control

with EGM

Drive

control

with EGM

2 Phase

Flow

New Coriolis Flow Measurement TechnologyThe positive effects of synthesized drive control with EGM

Page 12: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

Entrained Gas ManagementProduction of polyurethane foams

Page 13: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

Entrained Gas ManagementProduction of polyurethane foams

Material applications

• Used for insulating buildings

• Poor heat conductor

• Excellent thermal resistance

Measurement challenge

Air bubbles occur in the liquid (exothermic

reaction)

Benefits of EGM

Continuous measurement

Up to 100% GVF in the fluids

EGM meter does not stall

Continious measurement possible

Page 14: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

Entrained Gas ManagementOil and gas production

Page 15: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

Entrained Gas ManagementCrude oil production

Page 16: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

2017 Coriolis Update

15

• TWC9400

- High performance signal converter for all

applications

- Stable in multi-phase applications due to

Entrained Gas Management (EGM™)

- Highly developed diagnostic functions acc.

to NAMUR NE 107

- HART 7.4

• Coriolis 6000 and 200 Large line sizes

- High performance meter for process

industries

- Cryogenic, high temperature and high

pressure options

- Supreme liquid and gas performance

- High Pressure Solution

- Heating Jacket

- Up to 8” (C6000) and 14” (C200) with

flanges up to 16” and ANSI 1500#

All new electronics, sensors larger than ever

Page 17: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

Cryogenic & high temperature applications

-328°F to 752°F

Pressure capability up to 200 bar (2900 psi)

Developed According to SIL 2/3

Available from size 3/8” to 8” in 3 materials

316L Stainless Steel (S08 – S250)

Hastelloy C-22 (H08 – H80)

Duplex UNS31803 (D100 –D200)

No Pressure influence on density or mass flow

0.1% flat line accuracy / 0.05 % optional

Accuracy independent of process conditions

16

VersaFlow Coriolis 6000

Page 18: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

VersaFlow Coriolis 6000

17

Spigot with flow splitter

Node Plate

Sensor

Driver

Stem

Flange

Node Plate

Sensor

Bridge

Page 19: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

Application

Medium

Scope of supply

Project details

Process measurement

Bitumen

VFC 600-S200

Measuring high viscous Bitumen at 200 °C / 392 °F,

flow rate up to 110 t/h

(4040 lb/min).

8” VFC 6000Bitumen blending and loading

Page 20: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

• Launch of the highest capacity Coriolis flowmeter in

the world

• The first of its kind

• Flowrates up to 169,000 lb/min or 695,000 bbl/d

• Immunity to installation

• Provable with SVP

• Compact installation footprint

• Net Oil and Water Cut measurement

• Maintenance free VFC200 S400, the highest capacity Mass Flowmeter in the World

Introduction VFC200 S400Technological Innovation at its very best

Page 21: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

Measuring tube design pressure:

-1 to 180 bar / -14.5 to 2610 PSI (PED)

-1 to 130 bar / -14.5 to 2030 PSI (CRN)

The only meter on the market with internal pressure compensation

Process connection from 12” to 16”

Tube inner diameter 108.20 mm (4.26”)

±1kg/m3 (±0.0625 lbs/ft3)

±0.2 kg/m3 (±0.033 lbs/ft3) – on site calibration

CRN approved secondary containment

Complies with AGA, API and Directive 17

ATEX, IECEX, cFMus Approved

VFC200 S400Product Information

20

Page 22: NEW VERSAFLOW CORIOLIS - Honeywell2017 Coriolis Update 15 •TWC9400 - High performance signal converter for all applications - Stable in multi-phase applications due to Entrained

Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.

Driver

Pickup Sensors

Outer Casing

Four Straight Measuring Tubes

Unique patented decoupling nodes

Flexible Connection Options

VFC200 S400Meter design