WHITE PAPER: Installation Compliance
GENERAL:
INTENDED USE:PowerBridge Solution is certified for installation to provide a single location in-wall/ceiling power extension using code compliant building power cable within enclosed walls or ceiling areas. Installation conforms to NEC Chapter 3 Wiring Methods. Performs extension of 120-volt A.C. power from an existing power source, such as, not limited to; an existing installed outlet receptacle or external UL Listed power bar or extension surge protection device through external use of a UL Listed power supply cable.
BUILDING POWER CABLE: Nonmetallic-sheathed cable, also known as *ROMEX®, UL Listed NM-type cable is the most common and most accepted building premise power cable used for 120-volt wiring of lights, outlets and switches. Supplied 14-2 gauge NM-type building cable can be utilized in all areas of the US and
Canada where NM-type cable is approved to meet code compliancy. EXCEPTION: Cook County, IL – NYC, NY
-------
INSTALLATION PREMISE:Installation of the PowerBridge creates a dead-front extension, meaning it is not wired to the live premise branch- circuit power. PowerBridge remains as a dead-front, defined as without live parts until it is energized by means from the dead-front inlet through a suitable UL Listed power supply cord from the front of the existing power circuit, through its rated receptacle outlet. Benefit to this method of installation allows connection to an external power conditioner/surge protection device, bridging protected power in-wall to wall mounted display and audio appliances.
· PowerBridge is not installed as part of the building premise power circuit. · PowerBridge is not wired to, or made permanently part of, the building electrical circuit or branch-circuit. · Installation does not create a new circuit, also known as a branch-circuit or branch-circuit extension. · Installation does not change, modify, alter, or add-to, the premise power circuit as it is not direct wired to
the premise power circuit.
-------
POWERCONNECTOR NM-TYPE POWER CABLE CONNECTORS:BENEFITS: PowerBridge innovated use of pre-terminated NM Connectors for plug-together connection of supplied pre-terminated NM-type building power cable. No tools required. Installer friendly, no special training or skill required to connect. Safely and correctly allows fast plug-to-plug connection between the pre-terminated PowerIN and PowerOUT wall plates without hard wiring to termination screw attachment points. Ensures integrity of NM Cable connection, using secure locked termination points.
Conform to US Standards UL498, UL 514C, UL817 and Canadian CSA Standard C22.2 NOs 21, 42.1
Applicable products manufactured by HD Products for:
HD Products, LLC. PowerBridge Solution. 3869 Norwood Dr. #5 Littleton, CO 80125 | 303.683.2434 x300
|
© 2013 HD Products, Inc., PowerBridge Solution *ROMEX® is Trademark of the Southwire Company.
*© NEC® National Electrical Code® Trademarks of the NFPA
[email protected] www.PowerBridgeSolution.com
INSTALLATION CODE APPROVALS:Conforms for use within National Electrical Code (NEC)
Approval for PowerConnectors:*NEC Article 334.40 (B) Devices of Insulating Material. “- tap devices of insulating material shall be permitted to be used without boxes in exposed cable wiring for rewiring in existing buildings where the cable is concealed and fished. Openings in such devices shall form a close fit around the outer covering of the cable and the device shall fully enclose the part of the cable from which any part of the covering has been removed.”
Approval for installation of NM cable within walls:*NEC Article 334.30 (B) Unsupported Cables. “Nonmetallic-sheathed cable shall be permitted to be unsupported where the cable is fished between access points through concealed spaces in finished buildings or structures and supporting is impracticable.”
Approval for installation of assembled Listed kit:*NEC Article 400.7 (A) (11) Flexible Cords and Cables - Uses Permitted“Between an existing receptacle outlet and an inlet, where the inlet provides power to an additional receptacle outlet. The wiring interconnecting the inlet to the receptacle outlet shall be a Chapter 3 wiring method. The inlet, receptacle outlet, and Chapter 3 wiring method, including the flexible cord and fittings, shall be a listed assembly specific for this application.”
PowerBridge: ONE-CK, TWO-CK, SBCK, SWCK, CKRE, ONE-PRO, TWO-PRO, SWPR, SBPR
MODEL ONE-CK
Conceal cables and power for your wall mounted TV
Introducing the all new ONE-CK in-wall power and cable
management system. Single-gang size all-in-one design.
Designed to simplify wiring behind wall-mounted flat-panel TV’s
This discreet system allows low voltage cables and wires to be
routed through the wall for a clean look.
Code Compliant to install power, includes hardware and helpful
mounting template make the ONE-CK the perfect do-it-yourself
solution for any skill level, without the need for an electrician.
No wiring, simple snap together PowerConnectors make this
safe and easy.
4.5”
2.75”
Single-gang - Same size asa standard wall plate.
AV CablesIn-Wall
Power ExtensionIn-Wall
Recessed, in-wall installation
conceals component cables
for a flawless finished look
with brush pass-through
Recessed extra deep 1.5”Extra wide opening for all types of TV cords.Works with super-slim mounts, creating moreusable space behind your wall-mounted TV
One piece pre-assembledpower-wiring with connectorsDepth: 3.75” fits in any 2x4 - 2x6 framed wall
Code Compliant
6’ power-cord energizes
PowerINLET from existing
receptacle or external
surge protector.
MODEL
ONE-CKPRODUCT DIMENSIONS(w x d x h)2.75” x 3.00” x 4.5”6.9 x 9.5 x 11.4 cm
PACKAGE DIMENSIONS(w x d x h)7.75” x 4” x 7”18.3 x 10.6 x 17.8 cm
PACKAGE WEIGHT2.4 lbs / 10.7 kg
MASTER PACK QUANTITY10
FINISHWhite
AVAILABILITYCurrent
UPC855877002868
CODE COMPLIANCYSUPPORT1) NEC 2005 Article 334.40(B) PowerConnector tap-device
2) NEC Article 334.30Unsupported NM Cable
3) NEC 2014 Article 400.7(A)(11)Permitted use of cord / approved kitusing inlet to energize receptacle
Meets all US states and citiesadaptive to the NationalElectrical Code (NEC)allowing NM type building cable.Specific locations not allowing NM type building cable:~Cook County, IL~NYC, NY
Conforms to UL Standards498 & 514C
In-wall power connectors ensure simple snap connection without the need for an electrician.Pre-wired 80” in-wall wire
In-Wall Recessed Power Cable Management - PowerConnect
plug into surge protector
Pre-Wired In-Wall PowerConnectorsNo assembly of parts. No wiring to electrical system
Code Compliant throughout the US and Canada
Safe - Click-it together like a safety belt
CK - ConnectorKit Series ONE-CK, TWO-CK
So simple... You can do this!
MODEL TWO-CK
Conceal cables and power for your wall mounted TV
Introducing the all new TWO-CK in-wall dual outlet power
and cable management system. Perfect for motorized mounts.
Same size as standard dual and single wall plates.
Designed to simplify wiring behind wall-mounted flat-panel TV’s
This discreet system allows low voltage cables and wires to be
routed through the wall for a clean look.
Code Compliant to install power, includes hardware and helpful
mounting template make the TWO-CK the perfect do-it-yourself
solution for any skill level, without the need for an electrician.
No wiring, simple snap together PowerConnectors
make this safe and easy.
In-wall power connectors ensure simple snap connection without the need for an electrician.Pre-wired 80” in-wall wire
4.5”
2.75”
PowerINLET - Single-gangSame size as a standard wall plate.
AV CablesIn-Wall
Power ExtensionIn-Wall
Recessed, in-wall installationconceals component cablesfor a flawless finished lookwith brush pass-through
One piece pre-assembledpower-wiring with connectorsDepth: 3.75” fits in any 2x4 - 2x6 framed wall
Code Compliant6’ power-cord energizesPowerINLET from existingreceptacle or externalsurge protector.
MODEL
TWO-CKDual PowerConnect Kit
PACKAGE DIMENSIONS(w x d x h)8.5” x 4” x 8”21 x 10 x 19.3 cm
PACKAGE WEIGHT2.9 lbs / 12.1 kg
MASTER PACK QUANTITY10
FINISHWhite
AVAILABILITYCurrent
UPC855877002950
PowerOUTLET - Dual-gangSame size as a standard wall-plate.
CODE COMPLIANCYSUPPORT1) NEC 2005 Article 334.40(B) PowerConnector tap-device
2) NEC Article 334.30Unsupported NM Cable
3) NEC 2014 Article 400.7(A)(11)Permitted use of cord / approved kitusing inlet to energize receptacle
Meets all US states and citiesadaptive to the NationalElectrical Code (NEC)allowing NM type building cable.Specific locations not allowing NM type building cable:~Cook County, IL~NYC, NY
Recessed extra deep 1.5”Extra wide opening for all types of TV cords.Works with super-slim mounts, creating more usable space behind your wall-mounted TV
In-Wall Recessed Power Cable Management Dual Power - PowerConnect
plug into surge protector
PRODUCT DIMENSIONS(w x d x h)PowerINLET2.75” x 3.00” x 4.5”
PowerOUTLET4.5” x 3.25” x 4.5”
Pre-Wired In-Wall PowerConnectorsNo assembly of parts. No wiring to electrical system
Code Compliant throughout the US and Canada
Safe - Click-it together like a safety belt
CK - ConnectorKit Series ONE-CK, TWO-CK
So simple... You can do this!
SoundBar Power Solution with PowerConnect MODEL SBCK
Recessed, slim design power for your wall mounted SoundBar
Introducing the all new SBCK in-wall recessed power
and cable management system for popular wall-mounted
SoundBars.
Only 2.5” tall, designed to conceal behind slim SoundBars
This discreet system allows digital audio cables to be
routed through the wall for a clean look.
Compliments a complete in-wall installation when installed with
ONE-CK, TWO-CK, Power kits.
No wiring, simple snap together PowerConnectors make this
safe and easy.
SoundBar with TWO-CKDual Power Kit
AV CablesIn-Wall
Power ExtensionIn-Wall
Recessed, in-wall installationconceals audio cablesfor a flawless finished lookwith rubber pass-through
Completely recessed area for power cordConceals behind SoundBars, allowsfor ultra-close wall mounting
One piece pre-assembledpower-wiring with connectorsDepth: 2” fits in any 2x2 - 2x4 - 2x6 framed wall
MODEL
SBCKSoundBar Connector Kit
PRODUCT DIMENSIONS(w x d x h)11.75” x 2.0” x 2.5”29.8 x 5 x 64 cm
PACKAGE DIMENSIONS(w x d x h)12” x 5” x 3”30.5 x 12.7 x 7.6 cm
PACKAGE WEIGHT2.0 lbs / 8.9 kg
MASTER PACK QUANTITY10
FINISHWhite
AVAILABILITYJanuary 2014
UPC855877002974
CODE COMPLIANCYSUPPORT1) NEC 2005 Article 334.40(B) PowerConnector tap-device
2) NEC Article 334.30Unsupported NM Cable
3) NEC 2014 Article 400.7(A)(11)Permitted use of cord / approved kitusing inlet to energize receptacle
Meets all US states and citiesadaptive to the NationalElectrical Code (NEC)allowing NM type building cable.Specific locations not allowing NM type building cable:~Cook County, IL~NYC, NY
1’ PrewiredPowerConnectorto TV Outlet Connector
In-wall Digital Audio Cablefrom TV to SoundBar
SoundBar with ONE-CKSingle Power Kit
6’ PrewiredPowerConnectorto Power-Inlet Connector
Pre-Wired In-Wall PowerConnectorsNo assembly of parts. No wiring to electrical system
Code Compliant throughout the US and Canada
Safe - Click-it together like a safety belt
CK - ConnectorKit Series ONE-CK, TWO-CK
So simple... You can do this!
In-wall PowerConnector Extension MODEL CKRE
Extend PowerConnect Cable to remote location
Introducing the all new CKRE in-wall power cable extension.
Pre-assembled 10, 20, 30 foot lengths can be used to extend
up to an additional 50’ distance for remote power locations.
Ideal for custom installation above fireplace, remote
equipment closet/room.
Compliments a complete in-wall installation when installed with
ONE-CK, TWO-CK, and SBCK Power kits.
No wiring, simple snap together PowerConnectors make this
safe and easy.
MODEL
CKRE
PRODUCT DIMENSIONS(Length)10’- 20’ - 30’3.4 - 6.09 - 9.14 m
PACKAGE DIMENSIONS(w x d x h)7” x 2” x 7”17.78 x 5 x 17.78 cm
PACKAGE WEIGHT1.0 lbs / 4.5 kg
MASTER PACK QUANTITY5
AVAILABILITYCurrent
MODELSCKRE-10CKRE-20CKRE-30
CODE COMPLIANCYSUPPORT1) NEC 2005 Article 334.40(B) PowerConnector tap-device
2) NEC Article 334.30Unsupported NM Cable
Meets all US states and citiesadaptive to the NationalElectrical Code (NEC)allowing NM type building cable.Specific locations not allowing NM type building cable:~Cook County, IL~NYC, NY
Pre-Assembled 6’ Lengthfrom PowerOUT
Pre-Assembled 1’ Lengthfrom PowerIN
Pre-Assembled Power Connector ExtensionAvailable 10’ - 20’ - 30’Extend up to 50’
Extend TWO-CKDual Power Kit
Extend ONE-CKSingle Power Kit
Ideal for new home pre-wire
Pre-Wired In-Wall PowerConnectorsNo assembly of parts. No wiring to electrical system
Code Compliant throughout the US and Canada
Safe - Click-it together like a safety belt
CK - ConnectorKit Series ONE-CK, TWO-CK
So simple... You can do this!