new jersey center for science, technology, and mathematics education

21
New Jersey Center for New Jersey Center for Science, Technology, and Science, Technology, and Mathematics Education Mathematics Education John P. Mulhern April 15, 2008 Final Thesis Presentation

Upload: martina-mccall

Post on 01-Jan-2016

18 views

Category:

Documents


0 download

DESCRIPTION

New Jersey Center for Science, Technology, and Mathematics Education. John P. Mulhern April 15, 2008. Final Thesis Presentation. South Façade Perspective. Presentation Outline. General Building Information Lighting Design Theme Lighting Depth – Lower Lobby Electrical Depth - PowerPoint PPT Presentation

TRANSCRIPT

New Jersey Center for Science, New Jersey Center for Science, Technology, and Mathematics Technology, and Mathematics

EducationEducation

New Jersey Center for Science, New Jersey Center for Science, Technology, and Mathematics Technology, and Mathematics

EducationEducation

John P. MulhernApril 15, 2008

Final Thesis PresentationFinal Thesis Presentation

South Façade Perspective Presentation Outline

South Façade Perspective General Information¤ Owner: Kean University¤ Architect: Cannon Design, Inc.

+ MEP¤ Structural: Schoor Depalma Engineers

& Consultants¤ Civil Eng: K.S. Engineers, P.C.¤ CM: Provided by University¤ GC: Terminal Construction

Corporation¤ Location: Union, NJ¤ Size: 6 stories; 117,000 SF¤ Construction: September 2008

Start¤ Overall Cost: $45,000,000

General Info Lighting Electrical Breadths

South Façade Perspective Uses

http://constructlab.com/images/College%20University%20(23)%20cropped%20small.JPG

http://www.aviationtechcenter.com/images2/Computer_lab.jpg

http://paulstamatiou.com/wp-content/ uploads/ 2007/10/mizzou_macs.jpg

http://www.engin.umich.edu/caen/campcaen/ph otos/cave_princecar.jpg

http://photos.igougo.com/images/p9423-College_Station-My_22nd_Birthday_at_Garcias.jpg

http://www.allegany.edu/bedford/Images/BCCFacCWsmall.jpg

General Info Lighting Electrical Breadths

South Façade Perspective Lighting Design Theme

General Info Lighting Electrical Breadths

South Façade Perspective Overall Design Goals

General Info Lighting Electrical Breadths

Guide visitors through the irregularly shaped building with light

Provide recessed lighting wherever possible to keep ceilings clean

Incorporate luminaires which complement the modern architecture

Provide sufficient light levels for students

Plan Overall Design Goals

General Info Lighting Electrical Breadths

Guide visitors through the irregularly shaped building with light

Provide recessed lighting wherever possible to keep ceilings clean

Incorporate luminaires which complement the modern architecture

Provide sufficient light levels for students

N

Lobby Plan Lobby Information

General Info Lighting Electrical Breadths

Double height ceiling 21’6”

Café Area at south east corner

Color patterned and curved ceramic tile wall and grand stair case are focal points

Curtain wall on three sides with surrounding portico

Curtainwall

Terazzo Tile Floor Grand Staircase

Curved Ceramic Tile Wall

N

Lobby Plan Lighting RCP

General Info Lighting Electrical Breadths

N

D (LINEAR FLUORESCENT)

C(WALL WASHERS)

E(HALOGEN PENDANTS)

J(TRACK HEADS)

E(WALL WASHERS)

Lighting RCP East Perspective (Lobby Mode)

General Info Lighting Electrical Breadths

D (LINEAR FLUORESCENT)

C(WALL WASHERS)

E(HALOGEN PENDANTS)

J(TRACK HEADS)

E(WALL WASHERS)

Lighting RCP West Perspective

General Info Lighting Electrical Breadths

D (LINEAR FLUORESCENT)

C(WALL WASHERS)

E(HALOGEN PENDANTS)

J(TRACK HEADS)

H (WALL WASHERS)

Gala Mode

Auditorium Plan Auditorium Information

General Info Lighting Electrical Breadths

Staggered ceiling with coves at junctures

311 seats in auditorium

Staggered walls with vertical coves

N

Auditorium Plan Auditorium Information

General Info Lighting Electrical Breadths

Staggered ceiling with coves at junctures

311 seats in auditorium

Staggered walls with vertical coves

GWBMetal FasciaAcoustic PanelPerforated GWBCeramic Tile

N

Auditorium Plan Auditorium RCP

General Info Lighting Electrical Breadths

N

P (RECESSED CFL DOWNLIGHT

L (RECESSED LINEAR FLUORESCENT)

J&K (TRACK FIXTURES)

M (COVE FIXTURE)

O(WALL WASHER)

N (VERTICAL COVE FIXTURE)

Auditorium RCP South Perspective

General Info Lighting Electrical Breadths

P (RECESSED CFL DOWNLIGHT

L (RECESSED LINEAR FLUORESCENT)

J&K (TRACK FIXTURES)

M (COVE FIXTURE)

N (VERTICAL COVE FIXTURE)

O(WALL WASHER)

Auditorium RCP South Perspective

General Info Lighting Electrical Breadths

Linear Fluorescent

Lighting

Staggered Ceiling Cove Lighting

Estimate Aluminum Feeder Estimate

General Info Lighting Electrical Breadths

74 branch and distribution panels throughout building

117 major feeders with step down transformers

Assumed EMT conduit and runs in the ceiling on upper floors

Aluminum Feeders NOT RECOMMENDED

Cost Savings: $120,000.00

Experiment Room Introduction

General Info Lighting Electrical Breadths

Empirical Study of the mental effects of ceiling height at Univ. of Minnesota

Conducted tests on human information processing and cognitive skills

Result: Higher ceiling height increases cognitive skill strength

Higher Ceiling Height

Lower Ceiling Height

Auditorium Roof Plan Redesign

General Info Lighting Electrical Breadths

Raise Ceiling height of auditorium by 4 feet

Causes higher thermal load with more exterior wall area

More load from brick on CMU wall resting on strip foundation

Added SF 1804 SF

1.72 % of Total Exterior SF

Approximately 1.72% added to energy bill every year

Auditorium Roof Plan Methods

General Info Lighting Electrical Breadths

Binmaker program was used to organize TMY2 data

Solar air temperature calculation for loads

Fans in AHU-2 did not have to be resized

Acknowledgements

General Info Lighting Electrical Breadths

Dr. HouserDr. MistrickProfessor DannerthProfessor Davidson & Scott McCallDr. SrebricProfessor HollandProfessor Parfitt