new cadcam blocks for cerec overview - aug 2013 cadcam...instructions for use ordering # for flow...
TRANSCRIPT
![Page 1: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/1.jpg)
![Page 2: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/2.jpg)
![Page 3: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/3.jpg)
![Page 4: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/4.jpg)
IPS e.max CAD C16
![Page 5: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/5.jpg)
IPS e.max CAD – C16
• Larger Size Block
• Low translucency
• Shades: A1, A2, A3, A3.5, B1, B2, C1, C2, D2, BL2
• Indicated for single unit restorations• Full and partial coverage single units
• Large canines
• Restorations over custom abutments
![Page 6: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/6.jpg)
IPS e.max CAD 3-unit bridge
![Page 7: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/7.jpg)
Instructions for Use
Ordering # for Flow chart - 662640
![Page 8: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/8.jpg)
Indications / contraindicationsIndications• Up to three-unit bridges up to the second premolar
as the abutment tooth
Contraindications• Inlay bridges• Parafunction (e.g. bruxism)• Cantilever bridges• Maryland bridges• Pontic width > 11 mm in the anterior region• Pontic width > 9 mm in the premolar region• Any other use not listed as an indication for IPS e.max CAD
![Page 9: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/9.jpg)
Connector Dimensions
• Dimensions: 16 mm2
• Height >= Width
• Important: Currently, the new CEREC 4.2 software does NOT have a tool to measure the area of the connector
• The new E4D Software will have a measuring tool
![Page 10: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/10.jpg)
Processing options
![Page 11: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/11.jpg)
Staining technique using IPS e.max CAD Crystall
![Page 12: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/12.jpg)
Staining technique
Bridge after CAD/CAM milling – approximately8 minutes per unit = 24 minutes
Actual times may vary
Smooth out the attachment point and take proximal contacts into account.
![Page 13: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/13.jpg)
Staining technique
Do not use diamond discs for finishing, since this may result in predetermined breaking
points.
Finish interdental areas with fine-grit diamonds (grit size 40–50 µm). Make sure to observe the
connector dimensions.
![Page 14: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/14.jpg)
Staining technique
Check occlusion, articulation and proximal contacts.
Surface-grind the outer surface, particularly the functional areas of the restoration, with a
fine diamond to smooth out the surface structure created by the CAD/CAM process.
![Page 15: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/15.jpg)
Staining technique
Use the largest possible IPS e.max CAD Crystallization Pin for crystallization.
Fill the inside of the crowns of the previously cleaned bridge with IPS Object Fix Putty or Flow and press the appropriate IPS e.max CAD Crystallization Pin deeply into the IPS Object Fix material.
![Page 16: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/16.jpg)
Staining technique
Place the bridge on the IPS e.max CADCrystallization Tray immediately.
Smooth out displaced IPS Object Fix Putty or Flow with a plastic spatula from the margin towards the support pin so that the pin is
secured in the paste and the crown wall is precisely supported.
![Page 17: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/17.jpg)
Staining technique
Clean off any possible residue adhering to the outer surface of the restoration with a brush
moistened with water and then dry.
Apply IPS e.max CAD Crystall./Glaze paste evenly to the blue restoration.
Apply the mixed IPS e.max CAD Crystall./ Shades and Stains into the unfired IPS e.max
CAD Crystall./Glaze paste.
![Page 18: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/18.jpg)
Combination Firing – Glaze & Crystallize – P1
Place the IPS e.max CAD Crystallization Tray with the glazed and stained restoration in the furnace and conduct the combination firing.
Use Program P1
![Page 19: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/19.jpg)
Correction Firing – Use P1
If adjustments are required (shade, glaze, contact points), conduct a separate correctivefiring cycle on the IPS e.max CAD Crystallization Tray.
Use Program P1
![Page 20: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/20.jpg)
Staining technique
Completed IPS e.max CAD LT bridge.
![Page 21: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/21.jpg)
Firing parameters
![Page 22: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/22.jpg)
Cementation
![Page 23: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/23.jpg)
Conditioning of the restoration
Do not blast the restorations with Al2O3 or glass polishing beads.
Etch with 5% hydrofluoric acid (e.g. IPS®
Ceramic Etching Gel) for 20 seconds and rinse the acid off with water.
![Page 24: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/24.jpg)
Conditioning of the restoration
Allow Monobond® Plus to react for 60 s and then blow dry with the air syringe. Silanization is not required for
conventional cementation procedures.
![Page 25: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/25.jpg)
Dr. R. Watzke, Liechtenstein
![Page 26: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/26.jpg)
Dr. R. Watzke, Liechtenstein
![Page 27: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/27.jpg)
IPS e.max CAD 3unit bridge, R. Watzke, Liechtenstein
![Page 28: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/28.jpg)
IPS e.max CAD 3unit bridge, R. Watzke, Liechtenstein
![Page 29: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/29.jpg)
IPS e.max CAD 3unit bridge, R. Watzke, LiechtensteinIPS e.max CAD 3unit bridge, R. Watzke, Liechtenstein
![Page 30: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/30.jpg)
CEREC Owner Needs to do a Bridge
• Software version 4.2
• MCLX Mill
![Page 31: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/31.jpg)
New Blocks for CEREC
![Page 32: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/32.jpg)
all ceramic all options
![Page 33: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/33.jpg)
Available Now
New
New
![Page 34: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/34.jpg)
Coming…
![Page 35: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/35.jpg)
New Blocks for CEREC – Key Points• C16 & B32 will be at Patterson shortly
• Owners NEED software version 4.2 to be able to design and mill anterior bridges with the B32 block
• Stain, Glaze, & Crystallization process is similar to a single unit
• Crystallize & correction fire on P1
• Cementation options
![Page 36: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/36.jpg)
IPS e.max CAD Block Pricing
IPS e.max CAD Qty per Refill Whlse Retail
I12 5 $104.23 $161.50
C14 5 $104.23 $161.50
C16 5 $132.99 $205.00
B32 3 $214.83 $330.50
B40 current 3 $197.04 $280.00
B40L 3 $230.75 $355.00
A14 5 $199.49 $307.00
A16 5 $232.73 $360.00
![Page 37: New CADCAM Blocks for CEREC Overview - Aug 2013 CADCAM...Instructions for Use Ordering # for Flow chart -662640 . Indications / contraindications Indications • Up to three-unit bridges](https://reader033.vdocuments.site/reader033/viewer/2022041518/5e2c4d4743c89639c3649912/html5/thumbnails/37.jpg)