NEED FOR CARDIAC PACEMAKERRhythmic beating of heart originates from SA
nodeIf SA node doesn’t function properly results
in decreased heart rate & change in ECG waveform
![Page 3: NEED FOR CARDIAC PACEMAKER Rhythmic beating of heart originates from SA node If SA node doesn’t function properly results in decreased heart rate & change](https://reader036.vdocuments.site/reader036/viewer/2022083008/56649f335503460f94c5089b/html5/thumbnails/3.jpg)
PACEMAKER CONSIST OF 2 PARTSElectronic unitLead
![Page 4: NEED FOR CARDIAC PACEMAKER Rhythmic beating of heart originates from SA node If SA node doesn’t function properly results in decreased heart rate & change](https://reader036.vdocuments.site/reader036/viewer/2022083008/56649f335503460f94c5089b/html5/thumbnails/4.jpg)
ELECTRODESUNIPOLARBIPOLAR
![Page 5: NEED FOR CARDIAC PACEMAKER Rhythmic beating of heart originates from SA node If SA node doesn’t function properly results in decreased heart rate & change](https://reader036.vdocuments.site/reader036/viewer/2022083008/56649f335503460f94c5089b/html5/thumbnails/5.jpg)
TYPES OF PACEMAKEREXTERNAL PACEMAKER Used in cases of cardiac standstill Applied through metal electrode placed on surface of body It applies upto 80mA of pulses through 50sq.cm electrode on
chest
DISADVANTAGE Requires maximum of 150V pulses Electrodes tend to burn skin Electric pulses become painful Each impulse causes uncomfortable contraction of thoracic
muscles around the area under electrodes
![Page 6: NEED FOR CARDIAC PACEMAKER Rhythmic beating of heart originates from SA node If SA node doesn’t function properly results in decreased heart rate & change](https://reader036.vdocuments.site/reader036/viewer/2022083008/56649f335503460f94c5089b/html5/thumbnails/6.jpg)
INTERNAL PACEMAKERStimulating pulses can be applied to a heart
through a catheter passing through a vein & connected to heart
ADVANTAGESPacing current required is lessVoltage o/p of internal PM is about 0-15V
![Page 7: NEED FOR CARDIAC PACEMAKER Rhythmic beating of heart originates from SA node If SA node doesn’t function properly results in decreased heart rate & change](https://reader036.vdocuments.site/reader036/viewer/2022083008/56649f335503460f94c5089b/html5/thumbnails/7.jpg)
POWER SOURCELife of PM is determined by the current
consumption of electronic circuit and availability energy in the unit
Hg batteries, biological batteries, nuclear batteries, li cells.
Lithium iodide battery most commonly usedLife span:5-8 yrs
![Page 8: NEED FOR CARDIAC PACEMAKER Rhythmic beating of heart originates from SA node If SA node doesn’t function properly results in decreased heart rate & change](https://reader036.vdocuments.site/reader036/viewer/2022083008/56649f335503460f94c5089b/html5/thumbnails/8.jpg)
IMPLANTABLE PACEMAKERElectrodes are implanted beneath the skino/p leads are connected directly to the heart
musclePulse generator is powered by small batteries
![Page 9: NEED FOR CARDIAC PACEMAKER Rhythmic beating of heart originates from SA node If SA node doesn’t function properly results in decreased heart rate & change](https://reader036.vdocuments.site/reader036/viewer/2022083008/56649f335503460f94c5089b/html5/thumbnails/9.jpg)
PACEMAKERASYNCHRONOUSFixed rateImpulse produced at a set rateNo relation to patients intrinsic cardiac
activity
![Page 10: NEED FOR CARDIAC PACEMAKER Rhythmic beating of heart originates from SA node If SA node doesn’t function properly results in decreased heart rate & change](https://reader036.vdocuments.site/reader036/viewer/2022083008/56649f335503460f94c5089b/html5/thumbnails/10.jpg)
SYNCHRONOUSDemand modeSensing circuit searches for instrinsic
depolarization potentialIf absent, pacing response is generated
![Page 11: NEED FOR CARDIAC PACEMAKER Rhythmic beating of heart originates from SA node If SA node doesn’t function properly results in decreased heart rate & change](https://reader036.vdocuments.site/reader036/viewer/2022083008/56649f335503460f94c5089b/html5/thumbnails/11.jpg)
LEADSSUTURELESSPOROUS
![Page 13: NEED FOR CARDIAC PACEMAKER Rhythmic beating of heart originates from SA node If SA node doesn’t function properly results in decreased heart rate & change](https://reader036.vdocuments.site/reader036/viewer/2022083008/56649f335503460f94c5089b/html5/thumbnails/13.jpg)
THANK YOU