NE-104 / -204 / -304
1/02
- 201
6
1
N1
measuring
•
monitoring
•
analysing
KOBOLD Messring GmbHNordring 22-24D-65719 Hofheim/Ts.
Head Office: +49(0)6192 299-0
+49(0)6192 23398 [email protected] www.kobold.com
OO For use with conductive electrodes NES, NEW, NEH and LNK
OO Limit signal
OO Min. / Max. controller
OO Power supply: 230 VAC, 110 VAC, 24 VAC
Electrode Relays for Conductive Limit Switches
KOBOLD companies worldwide:
ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, REPUBLIC OF KOREA, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, USA, VIETNAM
-
2 www.kobold.com 1/02
- 201
6
No responsibility taken for errors; subject to change without prior notice.
Technical DetailsNE-104, NE-304Power supply: 230, 110, 24 VAC ± 15%; 50 - 60 HzPower input: NE-104: approx. 2 VA NE-304: approx. 4 VAFloating voltage: approx. 10 VACShort-circuit-current: approx. 0.5 mASensitivity: adjustable 0 - 50 kΩResponse time: approx. 1 sOutput: NE-104: 1 floating changeover contact NE-304: 2 floating changeover contactsSwitching capacity: max. 250 VAC, 5 A, 600 VAHousing: Makrolon®
Protection: housing: IP 40 terminals: IP 20Ambient temperature: -20 °C ... +60 °CDimensions: 75 x 55 x 110 mmInstallation: DIN rail mount or wall mountSignalling: LED red: monitoring state
NE-204 according to § 19 WHG Power supply: 24, 230 VAC ± 15%; 50 - 60 HzPower input: approx. 2 VAFloating voltage: approx. 20 VACShort-circuit-current: approx. 4 mASensitivity: approx. 50 kΩResponse time: approx. 1 sOutput: 1 floating changeover contactSwitching capacity: max. 250 VAC, 5 A, 600 VAHousing: MacrolonProtection: housing: IP 40 terminals: IP 20Ambient temperature: -20 °C ... +60 °CDimensions: 75 x 55 x 110 mmInstallation: DIN rail mount or wall mountSignalling: LED green: auxiliary power on LED red: open-circuit LED yellow: monitoring stateMonitoring the mains supply: by dropping out the switch contactMonitoring electrode: lead by dropping out the switch contact, red LED lights up
Description
KOBOLD electrode relays of model NE- are used with conductive level switches NES, NEH, NEW and LNK for level monitoring and control of conductive liquids.
An electrode relay NE-104 is required for single point signalling. It posses additionally a bi-stable interval relay which lock and is therefore suitable for pump control.
With relay NE-304 and a level conductive switch with two signal and one ground electrodes, two level limits could be detected.
The relay outputs could be configured as a Min. / Max. control or as a single limit switch.
The relay NE-204 is used together with the conductive level limit switch NEW for water contaminating liquids. This system complies with the requirements of the §19 WHG. It should be used for tanks and vessels for storage of non-flammable, water contaminating liquids.
Electrode Relays for Conductive Limit Switches Model NE-104 / -204 / -304
-
3www.kobold.com 1/02
- 20
16
55
75
55
75
55
75
NE-204
NE-204
10
250 VAC/5A
Leitungsbruch
21
9
Betrieb3 6 7 8
PE50Hz~ ~
230V
Z-65.13-195
10
250VAC/5A
Leitungsbruch
21
9
Betrieb3 6 7 8
PE50Hz~ ~
230V
Z-65.13-195
20x10 20x10 S/cm
50-60Hz230V 250VAC/5A 250VAC/5A
S/cm-6 -6
20x10 S/cm-6
20x10 S/cm-6
~1 2
~43 5
PE
86 7
9 10 12 13 1615
230V 250V50-60Hz
~ ~21 3
~2VA
6
PE
7 8
~5A
14 15 16
PE~
1 2
~
3
~230V 50-60Hz2VA 250V 5A
6 7
~
8
14 15 16
5
~spannung
1 2
Versorgungs-
~
3 4
PE
250VAC/5A
6 7 8
139 10 12 15 16
250VAC/5A
NE-304
NE-104
NE-104
NE-304
No responsibility taken for errors; subject to change without prior notice.
Electrode Relays for Conductive Limit Switches Model NE-104 / -204 / -304
Dimensions [mm]
Order Details (Example: NE-104 0)
Model Description Number of outputs Power supply
NE- Electrode relay
104 = 1 limit signal or 1 Min. / Max. controller
304 = 2 limit signals or 2 Min. / Max. controller
204 = 1 limit signal acc. to § 19 WHG
0 = 230 VAC
1 = 110 VAC*
2 = 24 VAC
* Not with NE-204