ndst qa for singlemuon analysis

25
nDST QA for singlemuon analysis nDST QA for singlemuon analysis WooJin J. Park WooJin J. Park Korea University Korea University Santa Fe Workshop, Jun. 22th 2004

Upload: luisa

Post on 14-Jan-2016

39 views

Category:

Documents


0 download

DESCRIPTION

nDST QA for singlemuon analysis. WooJin J. Park Korea University. Santa Fe Workshop, Jun. 22th 2004. Contents. Muon Event Vertex Analysis Vertex dependence Variation within a run Run by Run variation Last Gap Muon Analysis Last Gap Muon and Open charm Last gap muon and total momentum - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: nDST QA for singlemuon analysis

nDST QA for singlemuon analysisnDST QA for singlemuon analysis

WooJin J. ParkWooJin J. Park

Korea UniversityKorea University

Santa Fe Workshop, Jun. 22th 2004

Page 2: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 20042

Contents

Muon Event Vertex Analysis– Vertex dependence – Variation within a run– Run by Run variation

Last Gap Muon Analysis– Last Gap Muon and Open charm– Last gap muon and total momentum– Comparison of Run3 and Run4 data– Comparison of North and South arm

Page 3: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 20043

Z vertex Dependence

z [cm]

Normalized Muon Biased Z vertex

Beam

Absorber

Filter out decay muon by Z-vertex analysis

Muon yield increasing linearly as function of distance from the absorber, indicates /K decay muon is detected.

Linear shape of z vertex slope is because c~100 [m].

/K decay dominates single muons.

Prompt or punch through background has no vertex dependent.

Fe Cu

Beam

MuTr

BBC

Need to find Good Reference Vertex distribution!!

Page 4: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 20044

Reference Vertex Distribution – Run3 dAu

From Ming’s analysis note

Page 5: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 20045

Vertex Distribution – Run3 dAu

1. Use pro.48 Minbias nDST2. Total 504 runs3. Merge all segments for each run4. cut : abs(BBC_Z_vertex)<265. Fit with single gaussian function

Page 6: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 20046

Example Plot – Run3 dAu

Run # : 78633

Page 7: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 20047

Variation within a run – Run3 dAu

Quite Stable!!!

Page 8: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 20048

Variation over all runs – Run3 dAu

Page 9: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 20049

Vertex Distribution – Run4 AuAu

1. Use private repass Minimum Bias nDST samples

2. Total 162 runs3. Use first segment for each run4. The number of events per run is 70005. Fit with single gaussian function

Page 10: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200410

Example Plot – Run4 AuAu

Page 11: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200411

Variation within a run – Run4 AuAu

Page 12: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200412

Run by Run Variation – Run4 AuAu

Page 13: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200413

Last Gap Muon for Open Charm

?

Last Gap Muon

Gap3 Muon

Gap4 Muon

• Muon from the open charm has large momentum as compared with other muons

• There is every probability that it can be reached to the MuID last gap

• But we cannot measure the number of last gap muons directly

Page 14: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200414

Last Gap Muon for Run3 dAu

Page 15: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200415

Last Gap Muon for Run4 AuAu

Page 16: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200416

Number of Gap3, Gap4 and Last Gap Muon – Run4 AuAu

108000 110000 112000 114000 116000 118000 120000 122000

600

900

1200

1500

1800

2100

2400

2700

3000

3300

3600

3900

Nu

mb

er

of M

uo

n

Run Number

Last Gap Muon Gap4 Muon Gap3 Muon

Page 17: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200417

Last Gap Muon vs Total Momentum

Page 18: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200418

Page 19: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200419

To Do List from now on

Vertex Analysis– Need more study on Run4 AuAu data– Reference vtx distribution : run by run? seg by seg?– Make reference vtx distribution after production– Goodrun list based on vertex analysis

Last Gap Muon Analysis– Need to find good quality cut– Need to understand the correlation between gap3, gap

4, and last gap muon

Page 20: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200420

Summary

Vertex Analysis– We can separate decay muon and prompt muon by verte

x analysis small variation within a run large variation over the run large variation within a run small variation over the run

Last Gap Muon Analysis– We can separate open charm decay muons and hadron

decay muons by last gap muon analysis– Need more study on Run4 data

- Run 3 run by run reference

- Run 4 need more study!!

Page 21: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200421

BACKUP SLIDESBACKUP SLIDES

Page 22: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200422

Estimation of the Number of Last Gap Muon

iL

eNiN

0)(

Where, is the number of gap i pion

is the number of pion at vertex

is the total thicknesses of the absorber

is the slope

)(iN

0N

iL

Page 23: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200423

Estimation of the Number of Last Gap Muon

3

0)3(L

eNN

4

0)4(L

eNN

We can get and0N

5

0)5(L

eNN

Page 24: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200424

Run3 dAu

Run4 AuAu

Page 25: nDST QA for singlemuon analysis

Santa Fe Meeting, Jun. 22th 200425