natural vegetables & fruits storage pvt....

33
Natural Vegetables & Fruits Storage Pvt. Ltd. Plot No.13, Survey No.166, Opp. Shantidham Society, Veraval (Shapar), Ta:- Kotda Sangani, Dist:- Rajkot, Gujarat. Tel.:- +91 99099 56804 Fax:- (02827) 254149 Web :- www.nvfl.in E-mail :- [email protected]

Upload: others

Post on 01-Apr-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Natural Vegetables & Fruits Storage Pvt. Ltd.

Plot No.13, Survey No.166,

Opp. Shantidham Society,

Veraval (Shapar), Ta:- Kotda Sangani,

Dist:- Rajkot, Gujarat.

Tel.:- +91 99099 56804

Fax:- (02827) 254149

Web :- www.nvfl.in

E-mail :- [email protected]

Natural Vegetables & Fruits Storage Pvt. Ltd.

In Excellence Quest, Driven By

Quality NVFL enjoys a smooth ride in a growing market where the

demand for refrigeration products is on the increase. An overview

of the growth story.

For us, excellence is not an achievement but a continuous ongoing

process," says Natural Vegetables & Fruits Storage Pvt. Ltd. a quality

designer and manufacturer of industrial engineering application.

Perhaps, it is this single-minded focus on quality that has helped NVFL

climb heights.

With the demand for refrigeration industry rising in a fast-growing

nation like India. That will definitely provide growth opportunities for a

company like NVFL which is stepping up scale in the local as well as

export market.

The portfolio comprises turnkey solutions for Refrigeration Plants

utilized for Multy Purpose Cold Storage, Controlled atmosphere cold

storage for fruits, Frozen plants with IQF and allied processing

machinery, Fruits Ripening rooms, pre-cooling rooms, various type of

Ice Plants, Ice Conveying Systems, etc. The company also offers its

expertise in cold chain solutions with special purpose food processing

equipments like Vegetable Dryers.

Natural Vegetables & Fruits Storage Pvt. Ltd.

The company also represents some of the world’s best companies for their

products like Insulated Insulated Panels, Ventilation technology and

controlled atmosphere machinery for the industries.

Their technology utilized for fruits ripening plants is appreciated by

NABARD. Company has recently installed first of it’s kind of hi-tech

storage in Gujarat for onion, garlic, carrots and lemon with features

like storage in box, shorting & grading line, fully automatic plant, data

acquisition system. This Plant is desing and install after four year of

detail field servey. Company has successfully commenced Gujarat first

Cold chain Project under MOFPI scheme in Surat with all facility like

refer van, CA/MA cold storage , blast freezer, Frozen storage rooms,

Ripening rooms etc. Company is also in process of setting up of R & D

facility to collect storage data for fresh produce as per clients’ requirement.

We provide in-depth knowledge for specific commodity / produce right from

farming to storage to market.

Company has it strong present with his export presence in various regions

such as the Middle East, South Africa, Central America, and other parts of

the world. That speaks volumes for the quality of the company's focus. "Our

commitment to providing quality products at cost-effective prices and within

the committed time frame has given us the leading edge over others, and a

strong base of clients from all over the world.

Keeping alignment with the changing era of technology, Natural Vegetables

7 Fruits Storage Pvt. Ltd. has been satisfying the need of its numbers of

valued customers, fulfilling various challenging jobs, and being associated

with them in “chain – web". The company has a fully equipped

manufacturing facility in well-developed Industrial Zone situated near Rajkot

city of Gujarat.

Natural Vegetables & Fruits Storage Pvt. Ltd.

OUR ACHIVEMENTS

Natural Vegetables & Fruits Storage Pvt. Ltd.

Onion Analysis Report

This is in relation to the analyses of the onion sample; I brought

from Rajkot on August 5, 2011, performed at DOGR, Rajgurunagar. The

analysis revealed that the samples contained

Pyruvic acid (Precursor of Pungency): 3.95 µmoles/ g (fr. wt.)

Total Sugars: 194 mg/g (fr. wt.)

Ascorbic acid: 200 mg/g (fr. wt.)

The values for different attributes for quality parameters were found in normal limit as far as onion is concerned. However, since

the

control samples were not available for comparison it would be difficult to comment on the storage behavior of the commodity.

Further, there was no sprouting observed in the samples within this period of one month, which would be taken as reference for

further studies on storage of onions in CA storage. Therefore, we are planning to take comprehensive exercise next year to

gather complete data, if you permit the same.

While discussing on your CD/ literature on the CA storage with different entrepreneurs/ progressive farmer visitors at our

Insitute, the lack on approximate estimate constrains to convince them the importance properly. Thus, as requested you earIier,

kindly send me the cost estmates of CA storage with recurring cost per annum. Also, if possible the cost of same size of cold

storage for comparison at an early date.

With Regards

--

Dr. Ashutosh A. Murkute [Ph.D. (I.I.T. Delhi)]

Senior Scientist

Directorate of Onion and Garlic Research,

Indian Council of Agricultural Research

Rajgurunagar - 410505

Dist Pune, Maharashtra INDIA

VARIOUS COMPONENTS OF COLD STORAGE

Natural Vegetables & Fruits Storage Pvt. Ltd.

Civ

il W

ork

Str

uctu

re

Machin

e R

oom

Flo

oring

Panel In

sta

llation

Pa

lletized C

old

Sto

rage

Fru

its R

ipenin

g P

lants

Fro

zen P

lants

Pro

cessin

g M

achin

ery

Pro

cessin

g M

achin

ery

Flo

or

Insula

tion

Control Atmosphere Cold Storage for Storage of Fresh Fruits

NATURAL VEGETABLES &

FRUITS STORAGE P.LTD.

Plot No.3/4/5, Survey No.164,

S.I.D.C.Road,

Veraval (Shapar), Ta:- Kotda Sangani,

Dist:- Rajkot, Gujarat.

Tel.:- +91 99099 56805

Fax:- (02827) 254150

E-mail :- [email protected]

Company Strength

Focus of the Jaimin Engineering Pvt. Ltd. Is to providing turnkey Solutions

for post harvest project to it’s client in India and across the globe.

Company is working in this field for more than eleven years.

Company main strength is the centre team of more then 78 skilled work

which implements each project in time.

Company provides all it’s valued client in-depth knowledge of pre storage

parameters, storage parameters and after storage parameters, Which is very

essential for the success of the projects. Company also take operational

responsibility of the plant in initial phase and train the client before handover

the projects.

Present conventional storage system

The technology provided by jaiminengineering pvt. Ltd. For multi purpose CA / MA Cold Storage

. A) Storage Conditions Traditional masonry construction

technology with multy floor design is

used to construct the insulated

building.

In this storage system only

temperature is controlled

Profile of temperature within

chamber is varied from 1.5 to 2 deg C.

Modern construction techniques with

PUF insulated PEB structure is used to

construct the energy efficient insulated

building.

In this storage system apart from

temperature, humidity (High/Low), carbon

dioxide, oxygen, ethylene and air

circulation within product is controlled.

Uniform temperature is maintained

throughout the chamber. The temperature

difference between the products is as

minimum as 0.5 deg C

Normally material storage in jute or plastic bags, Corrugated boxes, tin etc. which restrict the uniform air circulation within the products. Material is damaged due to over weight stacking

Loading / Unloading of material is done manually. Which involve huge labour cost and injury to product is very high. Mechanized handling is very difficult during load / unload period. Power consumption is high as doors open for long time due to manual load / unload.

Material is stored in wooden bins.

This allowed the uniform air circulation

within the products. The material is

safe against the overload as uniform

destitution of material load is possible.

Mechanized handling is possible

and required less labour cost.

Load/unload time is reduced and

power consumption during this

operation is reduced.

B)Material Stacking / Handling

Normally designing of refrigeration systemdesign on higher ∆T to save the cost resultingin higher weight loss and qualitydeterioration.

Ventilation is not adequate because of the multy floor design.

Normally system operated manually andhence to maintain precise temperature spanis very difficult.

Data accusations is not possible.

To operate and control the system,physical presence required.

This storage facility restricted to singlecommodity

The system is design for rapid cooling with minimum ∆T (as of 2 to 2.5 deg C.) to minimize weight loss.

Because of the box storage systems & specially design ventilation system air circulation within the product is uniform the condensation problem is eliminated.

The system is fully automatic and temperature span can be controlled as minimum as 0.1 deg. C Resulting in uniform temperature profile within the room.

All the data accusations is available to evaluation any particular conditions of particular time.

Through internet plant can be operated from any part of the globe. Human error is totally eliminated.

Storage facility can be used for many varieties hance ROI is higher.

C) Operational systems

For your requirement of storage technology kindly

contact or mail to us.

[email protected]

[email protected]