n-biotek co2 incubator - medica.de · co2 ir sensor n2 gas control valve o2 gas control valve no...

41
NB-203M MINI-CELL N-BIOTEK CO2 Incubators

Upload: duongdiep

Post on 20-Aug-2019

234 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

NB-203M

MINI-CELL

N-BIOTEK CO2 Incubators

Page 2: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Advantages

of N-BIOTEK CO2 INCUBATOR

• 6 sides Direct heating

• Dry Wall and Air Jacket

• 3 Temperature Sensor Control

• Dual Beam IR CO2 Sensor

• 125℃ Dry Hot Air Decontamination

• Natural Humidification from Water Tray

Common FEATURE of CO2 Incubator

Stacked NB-203 & 203XL NB-203XXL

Page 3: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

BASIC FEATURES

Air Jacket -6 side direct heating

Control Panel

Magnetic Door Seal

Glass door

Door Latch

Outer door

Outer door heater -Prevent condensation

Ventilation Fan

Glass door heater -Prevent condensation

Stainless Steel Shelve -Perforated to improve uniformity

Inner door seal -Airtight to prevent Co2 leakage

Water pan -Heated by 6 sides direct heating for humidity

NB-203

Page 4: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

BASIC FEATURE

Back of CO2 Incubator

Control Panel of CO2 Incubator

Co2 Gas inlet Serial label

Overheating Safety

Power Cord

Spare Fuse

Page 5: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Excellent Temperature Control

Six sided direct heating

The advantage of 6 side direct heating

- Precise Temperature Control(Fast Warm up)

- Quick Recovery Time after opening door

3 Temperature Sensors

- For controlling Heaters in 3 Segment

- No Condensation on Glass Door

- Maximizing Uniformity

Natural And Force Air and Humidity Circulation

- Efficient Heating Element Arrangement.

- Horizontal Laminar Airflow System

- Excellent Uniformity of CO2, Temp, Humidity

Page 6: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Integrated Air Circulation System using both Natural and Force Convection

Heat Preservation in Air Jacket Between Chamber and Insulation

Air Circulation Diagram

Blow Fan

Page 7: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Detail of CO2 Incubator 1. Humidity Control – Natural Humidification(Water tray, Basic Function) This is a good way to maintain high humidity in chamber in order to protect FBS, MEM(kind of medium) dried. 2. Alarm (Basic Function) Alarm on when : 1) Temp : Over ±1 ℃ 2) CO2 Density: Over ±1% than Set point. High and Low Density 3) 30 Seconds After Door open 3. Calibration by One Touch Button (Basic Function) Difference Temp and CO2 Density between Display and Real Value Calibration is done by Pushing CALIBRATION button 4. Over Temp safety (Basic Function) OVER HEAT Limit DIAL

Page 8: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

6. Split Inner Glass Door (Optional)

Option of CO2 Incubator

5 Divided Door For NB-203

5. ACCESS PORT (Optional) To use this like outlet port 30mm Hole located on left side of incubator, which is able to apply various additional equipment or to probe inside of Chamber.

Benefits of Split Door 1. Effective Gas Consumption

2. Maintain consistent climactic condition

3. Reduce Gas Consumption

4. Minimizes any changes during door open

5. Fast Recovery Time

6. Reduce the risk of contamination

7. Maintain easy access to samples

6 Divided Door For NB-203XL

Page 9: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Option of CO2 Incubator 7. Cooling Option (Peltier) -5℃ from room temperature but the lowest temperature is up to 20℃

8. Customized Option: UV Lamp and HEPA filter

HEPA FILTER UV LAMP

Page 10: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Six sided direct heating HOT AIR is useful to destroy bacteria and germ and other

factors causing a contamination

3 Hours for Decontamination (125℃)

4 ~ 5 Hours to cool down to 37℃

Automatic Re-set at Temp & CO₂

Safety Door Lock

Option of CO2 Incubator 9. Hot Air Decontamination

Page 11: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Option of CO2 Incubator 10. O2 Control (Tri-gas control)

O₂ Function On/Off Key O₂ Adjustment Key

O₂ Set-up Button

O₂ Display LED window

Pilot Lamp for O₂ Injection Control (when O₂ injects into chamber,

Lamp is ON for 0%~22%)

Back of CO2/O2 Incubator

Control Panel of CO2/O2 Incubator

● NOTIFICATION: To create hypoxic condition(lower O₂ than atmosphere) N2 must be supplied.

● NOTIFICATION: To create hyperoxia condition(higher O₂ than atmosphere) O₂ must be supplied.

Page 12: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Option of CO2 Incubator 10. O2 Control (Tri-gas control)

Zirconia O2 Sensor

N2 Gas Control Valve O2 Gas Control Valve CO2 IR Sensor

No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor is installed outside chamber through a pipe like above.

Pipes connecting between chamber and sensor to chamber

Page 13: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Stacking Kit & Caster Option

Caster Base Tray Stacking Kit

Page 14: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Copper Chamber

NBIOTEK customize chamber with oxidizing copper / copper-plated chamber for enhanced contamination protection.

Page 15: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

MiniCell™ - 16L CO2 Incubator

Portable MINI CO2 Incubator

NB-203M

Page 16: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Features of MiniCell™

Portable MINI CO2 Incubator

• 16L Chamber, 6.8kg light to carry • Portable with carrying handle • Available size to use in work-station or Clean bench • Forced Air Circulation by Fan • 2 Stainless Steel Shelves as Standard (Max. 3 shelves) • Natural Humidification by water tray • Power Plug & Car Jack

Page 17: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Access Port of MiniCell™

Option of Portable MINI CO2 Incubator

• Ø12mm(Dia) Access Port with Silicon Stopper

Page 18: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

NB-203XXL(Max Cell™)

850L Large Capacity CO2 Incubator

850L, 185cm height

6 Sides direct heating system

2 Divided Glass doors

3 Standard Shelves (Max. 15 ea.)

UV Sterilization even during cell culture

Protect heat loss by Magnetic Sealing

Water Tray for Natural Humidity

Chamber made of SUS304

Dry wall and air jacket

Dual BEAM IR CO₂ sensor

Various options

Page 19: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

FEATURES of Large CO2 Incubator

Air Jacket -6 side direct heating

Control Panel

Magnetic Door Seal

Glass door Door Latch

Outer door

Outer door heater -Prevent condensation

Air Circulation Fan

Glass door heater -Prevent condensation

Inner door seal -Airtight to prevent air & CO₂ leakage

Water pan -Heated by bottom heater for Humidification

Door lock

Stainless Steel Shelve -3 shelves are standard -Perforated to improve uniformity

NB-203XXL

Page 20: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

CO2 Incubator with Shaker and Roller

NB-206CXL

NB-203QMS

NB-203QR NB-203QS

NB-206CL

Page 21: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

CO2 Incubator with Roller

179L CO2 Incubator with Built-in Roller

↑NB-203QR

Roller is placed on the bottom of Chamber

Adherent and suspension Cell culture

are simultaneously conducted at an incubator

Standard Accessories

– 4 Bottles (Φ100mm~120mm) & One Shelve

Controlling roller at outside control panel

Page 22: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

CO2 Incubator with Shaker

CO2 Incubator with Built-in Shaker Mini Shaker(NB-101S) is built in.

BLDC motor allows incubator LOW vibration, LOW particle occurrence, LOW noise

Adherent and suspension Cell culture can be simultaneously conducted in an incubator

Controlling internal shaker at outside control panel

↑ 179L, NB-203QS ↑47L, NB-203QMS ↑ 179L, NB-206CL

Page 23: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

NB-206CXL, 650Liter NB-206CXXL, 850Liter

Large Capacity CO2 Incubator Shaker

Page 24: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

AniCell™ Instruction

① ②

1) Shaker control panel

2) Incubator control panel

3) 3 Divided glass door

4) Outer door

5) Shaker (NB-101M)

6) Pullout shaker platform

7) Humidity tray

8) Magnetic door seal

9) Door latch

10) Air Circulation fan

11) Lockable caster

12) CO2 Input port

13) 4-20mA Analogue output port

14) Safety switch

15) Access port

⑫ ⑬ ⑭

Inner Door Open

Back of AniCell

Page 25: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Outer Door Open Actual Figure of AniCell

Detail of AniCell™

Page 26: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Features of AniCell™

Slide-out Shaker Platform Platform of each shakers can be pulled out for loading flasks on each shakers efficiently

Page 27: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

3 Mountable Medium Shaker (NB-101M) in One Incubator

Features of AniCell™

Page 28: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

• Door Latch with built-in magnetic 1. To avoid injury, when user stand up

from sitting to handle middle & bottom shakers.

2. Holding full three doors when taking shaker out or cleaning in chamber

3 Split Inner Glass Doors

• Advantages of split doors 1. Minimization for loss of Temp &

CO2& Humidity 2. Lower Affection to Shaker to Shaker 3. Auto Stop when door open 4. Full observation without loss

Features of AniCell™

Page 29: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Natural Humidification Large Water Tray is placed on the bottom of chamber. Bottom Heater warms up the water then natural humidification occur.

Features of AniCell™

Page 30: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Ceiling in Chamber

UV Light

Circulation Fan above Ceiling

UV lamp & Anti-Bacterial Filter

Features of AniCell™

HEPA Filter

Page 31: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Efficient Arrangement of

Heating Element For Natural Convection

Air Jacket

1. Forming Air Jacket

between Insulation and Chamber

2. Enhanced Heat Preservation

3. Helping Recovery Time faster

4. Longer Heat Preservation in power failure

5. Dense Heating Element for Fast Heat-Up

Features of AniCell™

Page 32: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

CO₂, Temperature, UV, Alarm control and Humidity display is on Right Panel

Control Panel of AniCell™

Temp. Set Key

Co2 charging signal

Heat-operating Signal

Alarm Mute

Co2 Set Key Calibration Set Key

Humidity Display UV ON/OFF

ALARM ON/OFF

RPM/TIME selection key

RPM/TIME SET key

START/STOP key

Each 3 Shakers can controlled individually and each Pilot Lamp displays running of each shakers

Page 33: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Fast heat-up of AniCell™

Page 34: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Fast Detection of CO2 Density

Display Real Density

Fast Recovery & Stable Maintains

Co2 Density Control by IR Sensor

Page 35: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Shaker of AniCell™

NB-206CXL NB-206CXXL

BLDC motor allows incubator

LOW vibration, LOW particle occurrence, LOW noise

Moisture resistant mechanism

Holder platform

Page 36: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Belt disconnection

Heat by friction

Disadvantages of using Belt connection shaker Higher Particle & Vibration & Noise from belt connection

Frictional heat occurred by Belt Working

Short life time caused by high humidity in CO2 incubator

(No water proof construction)

Regular Lubrication on Belt Connection is required

Shaker of AniCell™

Page 37: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

BLDC Magnetic Induction Direct Drive

Stable Shaking !

LOW vibration LOW Noise LOW heat LOW Particle! No Belt! No replacement! Longer Life Time Plate type and low height: Low Vibration

Shaker of AniCell™

Page 38: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Shaker Control outside chamber No Need to Open the door

For Shaker Operation

Epoxy Coated Coil Plate makes

Moisture-Resistant Mechanism

Durable Motor Mechanism & User Friendly Design Moisture Free ! Easy to Control !

Shaker of AniCell™

Page 39: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Stain Resistant Interior

Inner chamber & all shakers are

constructed with stainless steel SUS304

SUS304 is resistant to rust formation in

high humidity condition

Material of AniCell™

Page 40: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

OR

Various holders & Sticky mat

* Optimum performance for maximum allowance can be obtained at 150rpm.

Page 41: N-biotek CO2 Incubator - medica.de · CO2 IR Sensor N2 Gas Control Valve O2 Gas Control Valve No need to remove the Oxygen Sensor during Hot Air Sterilization because O₂ sensor

Thank You!!