mx bsc dimensioning
DESCRIPTION
MX BSC dimensioningTRANSCRIPT
Page 1
All rights reserved © 2006, AlcatelMx Platform
Agenda
Configurations and Capacity
Dimensioning rules
Page 2
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
Hardware configurationsBSC
stand-aloneMFS
stand-aloneRack sharing Rack sharing
MFS stand-alone
TRU
TerminationShelf
BSC
TRU
BSC1
TerminationShelf BSC1
TerminationShelf BSC2
BSC2
TRU
TerminationShelf
MFS
TRU
TerminationShelf
MFS
TRU
BSC
TerminationShelf BSC
MFS
TerminationShelf MFS
Standard config Standard config Large config2 x BSC config BSC + MFS config
Page 3
All rights reserved © 2006, AlcatelMx Platform
BSS topologies possible with MX BSC introduction in B9
G2BSC
G2BSC
G2BSC
MXBSC
MXBSC
MXBSC
MXBSCB9
MXBSCB9
MXBSCB9
G2BSCB9
G2BSCB9
G2BSCB9
MXMFSB9
MXMFSB9
MXMFSB9
STDMFSB9
OMCB9
1 MX MFS can be connected up to 21 BSCs.
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
Page 4
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
BSC/MFS HW configurations B8/B9
168168LIU board22MuxE1/LIU
shelf
1 to 12GP2SSW + RTMATCA
Shelf 2
1Spare GP91 to 9GP
1Spare CCP
321CCP2TPGSM
22OMCP22SSW + RTM
ATCA Shelf 1
21 GP9 GP600400200
MFS stand aloneBSC stand aloneEquipment
Rack shared configurations
1 rack receives:1 or 2 x ATCA shelfs, +
1 or 2 x LIU shelfs for
Stand-alone configurations
1 x BSC or
1 x MFS or
1 x extended MFS or
Rack-shared configurations
2 x BSC or
1 x BSC + 1 x MFS
Page 5
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
Capacity Impact BSC Evolution
HRB9: TRX configured for DR capacity are counted as 2x TRXB10: no impact
CS3/4No impact
EDGENo impact
AMRNo impact
Up to 500 cells and 1000 TRX per BSC Evolution with B10
Page 6
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
200 TRX 900
400 TRX 1800
150
600 TRX
BSC EvConfiguration
Max CS Load(Erlang)
BTSs
2600 (B9)2700 (B10)
255
255
800 TRX 3600
1000 TRX 4500
255
255
200
Cells
264
264
500
500
96
AbisE1
96
176
176
176
10
AterCSE1
20
30
40
48
12
AterPSE1
12
18
24
28
BSC Evolution capacity of each configuration
Page 7
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
BSC Evolution capacity of each configuration
MxBSC in B9
Full Rate TRX Dual Rate TRX
Configuration max. BTSs max. Cells max. BTSs max. Cells
BSC-EV-200 150 200 100 100 BSC-EV-400 255 264 200 200 BSC-EV-600 255 264 255 264
BSC-EV-RS 600-200 405 464 355 364 BSC-EV-RS 400-400 510 528 400 400 BSC-EV-RS 600-400 510 528 455 464 BSC-EV-RS 600-600 510 528 510 528
Note: For BSC-EV-200 and BSC-EV-400, the maximum number of BTS and cells with dual Rate TRX is lower than with Full Rate, because it is equal to the maximum number of TRX with dual rate.
Page 8
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
BSC Evolution capacity of each configuration
Configuration Nb. Of equipped telecom subracks
Number of CCP boards (*)
Number of LIU boards
BSC-EV-200 1 2 8 BSC-EV-400 1 3 8 BSC-EV-600 1 4 16
BSC-EV-RS 600-2001 2 6 24 BSC-EV-RS 400-400 2 6 16 BSC-EV-RS 600-400 2 7 24 BSC-EV-RS 600-600 2 8 32
(*) Spare CCP boards included1 The 600-200 configuration should be reserved for capacity extension purposes, otherwise the 400-400 configuration shall be preferred.
MxBSC in B9
Page 9
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
BSC Evolution capacity of each configuration
Nb VCE per CCP board = 114 (50 VTCU + 40 VDTC CS + 24 VDTC PS)
MxBSC in B9
ConfigurationType BSC-EV-200 BSC-EV-400 BSC-EV-600 Nb VTCU 50 100 150 Nb VDTC CS 40 80 120
Nb VCE CCP
Nb VDTC PS 24 48 72
Page 10
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
BSC Evolution capacity of each configuration
MxBSC in B9
Configuration Max. Nb. of TRX-FR
Max. Nb. of TRX-DR
BSC-EV-200 200 100 BSC-EV-400 400 200 BSC-EV-600 600 300
BSC-EV-RS 600-200 800 400 BSC-EV-RS 400-400 800 400 BSC-EV-RS 600-400 1000 500 BSC-EV-RS 600-600 1200 600
Page 11
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
BSC Evolution capacity of each configuration
MxBSC in B9
Configuration Max. Nb. Of Abis links BSC-EV-200 96 BSC-EV-400 96 BSC-EV-600 176
BSC-EV-RS 600-200 272 BSC-EV-RS 400-400 192 BSC-EV-RS 600-400 272 BSC-EV-RS 600-600 352
Page 12
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
BSC Evolution capacity of each configuration
MxBSC in B9
Configuration Ater CS(*) Ater ¨PS(**) BSC-EV-200 10 6 BSC-EV-400 20 12 BSC-EV-600 30 18
BSC-EV-RS 600-200 40 24 BSC-EV-RS 400-400 40 24 BSC-EV-RS 600-400 50 30 BSC-EV-RS 600-600 60 36
(*) With BSC evolution, the A-ter links provided for CS can be used for CS and PS. These links can be either fully dedicated to PS or CS, or it is also possible to split some A-ter links between CS and PS. (**) With BSC evolution the Ater links provided to PS are dedicated to PS only.
Page 13
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
BSC Evolution capacity of each configuration
Abis and Ater Allocation on LIU boards / BSC Capacity
1 x CCP board for 200TRX
1xLIU board for 16xE1 (Tx / Rx)
( => 1 x E1 cable )1xLIU Shelf manage:
16xLIU boards
=>1x LIU shelf = 256 x E1links max
Main figures:1000 TRX
200 TRXLIU 1 LIU 2 LIU 3 LIU 4 LIU 5 LIU 6 LIU 7 LIU 8 LIU 9 LIU 10 LIU 11 LIU 12 LIU 13 LIU 14 LIU 15 LIU 16
1 1 17 33 49 65 81 97 113 129 145 161 41 31 21 2 12 2 18 34 50 66 82 98 114 130 145 162 42 32 22 4 33 3 19 35 51 67 83 99 115 131 147 163 43 33 23 6 54 4 20 36 52 68 84 100 116 132 148 164 44 34 24 8 75 5 21 37 53 69 85 101 117 133 149 165 45 35 25 10 96 6 22 38 54 70 86 102 118 134 150 166 46 36 26 12 117 7 23 39 55 71 87 103 119 135 151 167 47 37 27 14 138 8 24 40 56 72 88 104 120 136 152 168 48 38 28 16 159 9 25 41 57 73 89 105 121 137 153 169 x 39 29 18 17
10 10 26 42 58 74 90 106 122 138 154 170 x 40 30 20 1911 11 27 43 59 75 91 107 123 139 155 171 x 24 18 12 1112 12 28 44 60 76 92 108 124 140 156 172 x 23 17 10 913 13 29 45 61 77 93 109 125 141 157 173 28 22 16 8 714 14 30 46 62 78 94 110 126 142 158 174 27 21 15 6 515 15 31 47 63 79 95 111 127 143 159 175 26 20 14 4 316 16 32 48 64 80 96 112 128 144 160 176 25 19 13 2 1
Abis ports (max 176)Ater CS (max 48)Ater PS (max 28)
200
400
400
200
200 TRX400 TRX 400 TRX
1000 TRX
600 TRX 600 TRX800 TRX 800 TRX
Abis ports Ater Ports
Page 14
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
BSC Evolution capacity of each configuration
MxBSC in B9
BSC-Evolution Configuration Maximum Traffic (ERLANG)
Maximum BHCA
BSC-EV-200 900 64 800 BSC-EV-400 1800 129 600 BSC-EV-600 2600(*) 187 200
BSC-EV-RS 600-200 3500(*) 252 000 BSC-EV-RS 400-400 3600 259 200 BSC-EV-RS 600-400 4400(*) 316 800 BSC-EV-RS 600-600 5200(*) 374 400
(*) Limitation with B9 release. Target for further releases is 900 ERLANG per CCP for all configurations
Page 15
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
Capacity Impact MFS Evolution
HRno impact
CS3/4CS1/CS2: 240 PDCHCS3/CS4: 208 PDCH
EDGEMCS5: 176 PDCHMCS6: 164 PDCHMCS7: 132 PDCHMCS8: 116 PDCHMCS9: 108 PDCH
AMRNo impact
MFS Evolution (GP board):Guaranteed in B9:
double number of PDCHTarget:
four times more (B9 MR4)
Page 16
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
MFS EvConfiguration
Max PDCHPer GP (B8/B9MR4)Max GP
STANDARD 240/960
LARGE 240/960
9+1
21+1
Cells(B8orB9/B10)
3000/4000
30004000
AterPS+Gb E1
12 or 16
12 or 16
Max GPPer BSC
6
6
Max BSCPer GP
1
1
MFS Evolution capacity of each configuration
Page 17
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
Max CS Max nb of PDCH per GP (A9130) CS2 960 CS3 892 CS4 804
MFS Evolution capacity of each configuration
MxMFS in B9
GPRS PDCH
EDGE PDCH
Note: For the GP board; the maximum number of PDCH is indicated for the configuration with 16 links per GP.
Max EGPRS MCS Max nb of PDCH per GP (A9130) MCS 1 856 MCS 2 836 MCS 3 796 MCS 4 772 MCS 5 704 MCS 6 660 MCS 7 448 MCS 8 380 MCS 9 348
Page 18
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
MFS Evolution capacity of each configuration
MxMFS in B9
The following LIU/GP configurations are supported:
TTP Number Synchronization Prefered Relative Position to BSC
Maximum MFS Subrack Number
Configurations
12 TTP centralized autonomous
remote / colocalized
2 subracks 21 GP 9 GP
14 TTP centralized remote G2 BSC 1 subrack 8 GP 16 TTP autonomous colocalized G2 BSC 1 subrack 8 GP
Page 19
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
MFS Evolution capacity of each configuration
Main figures:
Standard case:12 LIU ports per GPto get maximum number of 21 GP in a MFS(14 or 16 LIU ports per GPAccording to configuration)
1xLIU board for 16xE1 (Tx / Rx)
( => 1 x E1 cable )1xLIU Shelf manage:
16xLIU boards
=>1x LIU shelf = 256 x E1links max
Ater Allocation on LIU boards for stand alone MFS
LIU 1 LIU 2 LIU 3 LIU 4 LIU 5 LIU 6 LIU 7 LIU 8 LIU 9 LIU 10 LIU 11 LIU 12 LIU 13 LIU 14 LIU 15 LIU 161 1 17 33 49 65 81 97 113 129 145 161 177 193 209 225 2412 2 18 34 50 66 82 98 114 130 145 162 178 194 210 226 2423 3 19 35 51 67 83 99 115 131 147 163 179 195 211 227 2434 4 20 36 52 68 84 100 116 132 148 164 180 196 212 228 2445 5 21 37 53 69 85 101 117 133 149 165 181 197 213 229 2456 6 22 38 54 70 86 102 118 134 150 166 182 198 214 230 2467 7 23 39 55 71 87 103 119 135 151 167 183 199 215 231 2478 8 24 40 56 72 88 104 120 136 152 168 184 200 216 232 2489 9 25 41 57 73 89 105 121 137 153 169 185 201 217 233 249
10 10 26 42 58 74 90 106 122 138 154 170 186 202 218 234 25011 11 27 43 59 75 91 107 123 139 155 171 187 203 219 235 25112 12 28 44 60 76 92 108 124 140 156 172 188 204 220 236 25213 13 29 45 61 77 93 109 125 141 157 173 189 205 221 237 25314 14 30 46 62 78 94 110 126 142 158 174 190 206 222 238 25415 15 31 47 63 79 95 111 127 143 159 175 191 207 223 239 25516 16 32 48 64 80 96 112 128 144 160 176 192 208 224 240 256
Configurations for 4, 9, and 21 GPUsColors shown affectation of LIU per GPU
GPU 1, 5, 9, 13, 17, 21
GPU 2, 6, 10, 14, 18
GPU 3, 7, 11, 15, 19
GPU 4, 8, 12, 16, 20
21 x GPU
4 x GPU9 x GPU
Page 20
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
MFS Evolution capacity of each configuration
Ater Allocation on LIU boards for stand alone MFS with only 1 subrack
LIU 1 LIU 2 LIU 3 LIU 4 LIU 5 LIU 6 LIU 7 LIU 8 LIU 9 LIU 10 LIU 11 LIU 12 LIU 13 LIU 14 LIU 15 LIU 161 1 17 33 49 65 81 97 113 129 145 161 177 193 209 225 2412 2 18 34 50 66 82 98 114 130 145 162 178 194 210 226 2423 3 19 35 51 67 83 99 115 131 147 163 179 195 211 227 2434 4 20 36 52 68 84 100 116 132 148 164 180 196 212 228 2445 5 21 37 53 69 85 101 117 133 149 165 181 197 213 229 2456 6 22 38 54 70 86 102 118 134 150 166 182 198 214 230 2467 7 23 39 55 71 87 103 119 135 151 167 183 199 215 231 2478 8 24 40 56 72 88 104 120 136 152 168 184 200 216 232 2489 9 25 41 57 73 89 105 121 137 153 169 185 201 217 233 249
10 10 26 42 58 74 90 106 122 138 154 170 186 202 218 234 25011 11 27 43 59 75 91 107 123 139 155 171 187 203 219 235 25112 12 28 44 60 76 92 108 124 140 156 172 188 204 220 236 25213 13 29 45 61 77 93 109 125 141 157 173 189 205 221 237 25314 14 30 46 62 78 94 110 126 142 158 174 190 206 222 238 25415 15 31 47 63 79 95 111 127 143 159 175 191 207 223 239 25516 16 32 48 64 80 96 112 128 144 160 176 192 208 224 240 256
Configurations for 4, 9 GPUsColors shown affectation of LIU per GPU
GPU 1, 5
GPU 2, 6
GPU 3, 7
GPU 4, 8
4 x GPU8 x GPU
Page 21
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionConfigurations and Capacity
MFS Evolution capacity of each configuration
Ater Allocation on LIU boards on MFS rack shared with BSC
LIU 1 LIU 2 LIU 3 LIU 4 LIU 5 LIU 6 LIU 7 LIU 8 LIU 9 LIU 10 LIU 11 LIU 12 LIU 13 LIU 14 LIU 15 LIU 161 1 17 33 49 65 81 97 113 129 145 161 177 193 209 225 2412 2 18 34 50 66 82 98 114 130 145 162 178 194 210 226 2423 3 19 35 51 67 83 99 115 131 147 163 179 195 211 227 2434 4 20 36 52 68 84 100 116 132 148 164 180 196 212 228 2445 5 21 37 53 69 85 101 117 133 149 165 181 197 213 229 2456 6 22 38 54 70 86 102 118 134 150 166 182 198 214 230 2467 7 23 39 55 71 87 103 119 135 151 167 183 199 215 231 2478 8 24 40 56 72 88 104 120 136 152 168 184 200 216 232 2489 9 25 41 57 73 89 105 121 137 153 169 185 201 217 233 249
10 10 26 42 58 74 90 106 122 138 154 170 186 202 218 234 25011 11 27 43 59 75 91 107 123 139 155 171 187 203 219 235 25112 12 28 44 60 76 92 108 124 140 156 172 188 204 220 236 25213 13 29 45 61 77 93 109 125 141 157 173 189 205 221 237 25314 14 30 46 62 78 94 110 126 142 158 174 190 206 222 238 25415 15 31 47 63 79 95 111 127 143 159 175 191 207 223 239 25516 16 32 48 64 80 96 112 128 144 160 176 192 208 224 240 256
Configurations with 4 and 8 GPUs in rack shared with option 16 E1 /GPColors shown affectation of LIU per GPU
GPU 1, 5
GPU 2, 6
GPU 3, 7
GPU 4, 8
4 x GPU8 x GPU
Page 22
All rights reserved © 2006, AlcatelMx Platform
Agenda
Configurations and Capacity
Dimensioning rules
Page 23
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionDimensioning rules
Dimensioning rules for BSC
ATCA Shelf
MX BSC
CCPCCP
CCPboard
BTS 1
BTS 2
BTS 3
BTS 4
BTS 5
BTS k
AbisE1 links
LIU board
1
LIU board
2
LIU board
3
LIU board
LIU board 16
LIU board 15
LIU board 14
LIU board
LIU Shelf
Ater CS & PS
E1 links
Page 24
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionDimensioning rules
Dimensioning rules for BSC
Dimensioning rules regarding TRX and E1 links
One CCP board can manage up to 200 TRXs
(50 VTCU * 4 TRX-FR)
LIU Shelf manage: 16 x 16 E1 = 256 E1 links max
Page 25
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionDimensioning rules
Dimensioning rules for BSC
Dimensioning rules regarding TRX and E1 links
The "TCU allocation Evolution" feature enables the removal of different constraints in A9130 BSC Evolution due to flexible TCU allocation approach. All TCUs across CCP boards belong to one pool, where any Abis signaling TS allocation can be routed to any TCU across CCPs boards. We can allocated any available TCU from the TCU pool from configuration point of view.
In A9130 BSC Evolution, TCU allocation only involve the mapping of signaling channels i.e. RSL/OML on a TCU. Since traffic will be switched within TPGSM, it does not make sense to map TCHs & EXTS on to the TCU.We still have the following constraint for TCU allocation:
• TCU can handle maximum of 4 FR TREs (4 RSLs) or 2 FR + 1 DR TREs (3 RSLs) or 2 DR TREs (2 RSLs). In other words TCU can handle maximum of 4 Eq. FR RSLs• TCU can handle maximum of 3 OMLs.
Page 26
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionDimensioning rules
Dimensioning rules for BSC
BSC for B9 Release
Number of TRX 600
Max number of BTS 255
Max number of cells 264
Total Number of E1 224
Number of Abis 176
Number of Ater CS 30
Number of Ater PS 18
Number of Erlangs 2600
Traffic Ater PS (Mb/s) Max 40
Dimensioning rules regarding TRX and E1 links
Page 27
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionDimensioning rules
Dimensioning rules for MFS
Dimensioning rules regarding E1 links per GP
12 E1 links per GP board for all cases
(*) OPTION: As no extension possible for MFS in rack shared, options 14 x E1per GP or 16 x E1 per GP are proposed then maximum number of GP is limited to 8 GP instead of 9 GP.
Page 28
All rights reserved © 2006, AlcatelMx Platform
EVOLIUM™ A9130 BSC/MFS EvolutionDimensioning rules
Dimensioning rules for MFS
Dimensioning rules regarding E1 links per GP
One GP board can support:- 12 E1 links per GP board for all cases- up to 16 external links (A-ter + Gb), with a maximum of 16 GP board per MFS. - When the number of GP boards in the MFS is more than 16, the number of external links per GP is limited, so that the total number of links per MFS is not exceeded (12 per GP for the maximum MFS configuration of 21 GP). - The maximum number of links from one GP board to the SGSN is 8.