mutr chamber properties
DESCRIPTION
MuTr Chamber properties. K.Shoji Kyoto Univ. Measurement of MuTr raw signal. Use oscilloscope & LabView Read 1 strip HV 1850V Gas mixture Ar:CO 2 :CF 4 =50%:30%:20%. Total resistance 10kohm. Typical Pulse Shape. 3000 samples. Fit to these region. Ground Level Noise Subtract. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: MuTr Chamber properties](https://reader036.vdocuments.site/reader036/viewer/2022062322/568145ef550346895db2f4ec/html5/thumbnails/1.jpg)
MuTr Chamber properties
K.Shoji
Kyoto Univ.
![Page 2: MuTr Chamber properties](https://reader036.vdocuments.site/reader036/viewer/2022062322/568145ef550346895db2f4ec/html5/thumbnails/2.jpg)
Measurement of MuTr raw signalUse oscilloscope & LabView
Read 1 strip
HV 1850V
Gas mixture Ar:CO2:CF4=50%:30%:20%
Total resistance
10kohm
![Page 3: MuTr Chamber properties](https://reader036.vdocuments.site/reader036/viewer/2022062322/568145ef550346895db2f4ec/html5/thumbnails/3.jpg)
Typical Pulse Shape
![Page 4: MuTr Chamber properties](https://reader036.vdocuments.site/reader036/viewer/2022062322/568145ef550346895db2f4ec/html5/thumbnails/4.jpg)
Fit to these region
Ground Level Noise Subtract
Event-by-event ground level noise subtract
Use linear function y=gradient*x+intercept
3000 samples
![Page 5: MuTr Chamber properties](https://reader036.vdocuments.site/reader036/viewer/2022062322/568145ef550346895db2f4ec/html5/thumbnails/5.jpg)
Decay time
Detector Capacitance C
Total ResistanceR=9800ohm ~ 10Kohm
Exp(-t/CR)
Fit Error <300nsec
CR ~ 2.8usec C⇒ ~ 300pF (?)
![Page 6: MuTr Chamber properties](https://reader036.vdocuments.site/reader036/viewer/2022062322/568145ef550346895db2f4ec/html5/thumbnails/6.jpg)
Pulse Height and Charge distribution
Distribution of 1 StripTypical Charge is 200fCBut I used narrow scintillator for trigger,These distribution has dependence of place
Pulse height
chargePulse Height Charge
![Page 7: MuTr Chamber properties](https://reader036.vdocuments.site/reader036/viewer/2022062322/568145ef550346895db2f4ec/html5/thumbnails/7.jpg)
Correlation of Pulse Height & Charge
There is clear correlation.But little bit rise where pulse height is lowBecause of the Noise?
![Page 8: MuTr Chamber properties](https://reader036.vdocuments.site/reader036/viewer/2022062322/568145ef550346895db2f4ec/html5/thumbnails/8.jpg)
Simple Model
Cross mark isProfile of pulseheight&charge
Red is Model Line
![Page 9: MuTr Chamber properties](https://reader036.vdocuments.site/reader036/viewer/2022062322/568145ef550346895db2f4ec/html5/thumbnails/9.jpg)
ASD Chip for MuTr LL1 Trigger
4 Channels for 1 Chip
Input Impedance 370ohmPreamp Integration Time 80nsecPreamp gain 0.8mV/fCENC 2000electrons for 300pF⇒Analog output
Main amp gain 7Comparator with LVDS outputThreshold voltage : common for all 4 channels⇒Digital output
![Page 10: MuTr Chamber properties](https://reader036.vdocuments.site/reader036/viewer/2022062322/568145ef550346895db2f4ec/html5/thumbnails/10.jpg)
Expected Response of ASD Chip
Input Impedance 370ohm
Preamp Integration Time 80nsec
Preamp gain 0.8mV/fC
C ~ 300pF ⇒ CR ~ 110nsec
Analog outputRise time : few ~ 10nsec
![Page 11: MuTr Chamber properties](https://reader036.vdocuments.site/reader036/viewer/2022062322/568145ef550346895db2f4ec/html5/thumbnails/11.jpg)
Linearity of ASD Chip1Kohm load
Linearity of Analog output is wrong where charge>500fC
![Page 12: MuTr Chamber properties](https://reader036.vdocuments.site/reader036/viewer/2022062322/568145ef550346895db2f4ec/html5/thumbnails/12.jpg)
From now…
• Correlation with neighbor strips• Try to Change HV or Gas mixture• Time Response
Leading edge fluctuation from ion drift time<100nsec• ENC 2000electrons for 300pF
~ 0.3fC
Requirement is less than 1%• Can we get 100um resolution with ASD Chip?