TechnicalInformationTI 169F/00/en
Operating Instructions017196-1000
ApplicationThe Multicap DC 11 probe is primarilydesigned for continuous levelmeasurement and limit detection inliquids.
The wide selection of corrosion-resistantmaterials used for the probe rod,insulation and process connectionensures that it can withstand extremelycorrosive products.
The tried-and-tested, ruggedconstruction is gas-tight for pressuresfrom vacuum to 100 bar (1450 psi)gauge. Seal and insulation materialsenable it to be used with operatingtemperatures in the vessel of-80°C to +200°C (-110°F to +390°F).
Features and Benefits
• Optimum adaptation to yourapplication thanks to a wide range ofprocess connections and practicalvariations
= reliable function at a cost-effective price
• Protection against condensation in thenozzle
= reliable function even withcondensation
• Active build-up compensation for limitdetection
= constant and accurate switchpointeven with heavy build-up on theprobe, no cleaning or recalibration required
Level Probemulticap DC 11
Fully insulated rod probes
Hauser+EndressNothing beats know-how
Measuring System The measuring system consists of:• Multicap DC 11 probe• EC... electronic insert in the probe
housing• Silometer FMC...(Z) transmitter.
orNivotester FTC...(Z) level limit switch
Certified applicationsPlease note all specifications in thecertificates and appropriate regulationsas well as the instructions given in thisTechnical Information.
For limit detection in liquids with heavybuild-up or for detecting interfacelayers, the measuring system consistsof:• Multicap DC 11 probe with active
build-up compensation• EC 16 Z electronic insert• FTC 520/521 Z or FTC 470/471 Z level
limit switch.The limit input of the SilometerFMC 671 Z can also be connected.
EC ...
SilometerFMC ...
EC 61
EC 61
NivotesterFTC 422
or
EC ...
> 80 °C HMC ...
HTC ...
FMC ... FTC ...
or
or
EC ...
NivotesterFTC ...
EC 16 Z
NivotesterFTC ...
Left:continuousmeasurement;shown here, e.g. probewith screening againstcondensation in thenozzle
Right:Limit detection;shown here, e.g. probewith ground tube for usein plastic tanks
Left:Two-point controlwith one vertical or twolaterally mounted fullyinsulated probes
Right:Limit detection;shown here, e.g. probewith screening andactive build-upcompensation forreliable limit detectioneven with extremebuild-up
Separate mounting ofthe electronic insert withan excessively highambient temperature forthe probe head housing
2
Operating Principle The probe and vessel wall or counterelectrode form a capacitor with adefined, low capacitance when theprobe is in air.As soon as material covers the probe aparallel circuit is formed consisting of amuch larger capacitance and theresistance of the material – theimpedance.This means, that for materials with aconductivity which exceeds a specific,low threshold, any changes in dielectricconstant and, therefore, in thecapacitance no longer affect themeasurement.Screening on the probe prevents effectscaused by build-up of material orcondensation in the vicinity of theprocess connection. Probes with activebuild-up compensation for limitswitching cancel out effects of build-upon the probe.
Here are just a few notes on the variousdesigns for the fully insulated MulticapDC 11 probe:
➀ Probe without ground tube• for conductive liquids• for high viscosity liquids • for bulk solids
➁ Probe with ground tube• for non-conductive liquids• for use in agitator vessels
➂ Probe with screening• for long nozzles • for condensation on the roof of the
vessel• for build-up on the vessel wall
➃ Probe with fully insulatedscreening• as above but for especially
corrosive materials
➄ Probe with active build-upcompensation for limit detection• with heavy (conductive) build-up
on the probe.The active build-up compensationof the Multicap DC 11 probe isalways gas-tight due to theself-adjusting tapered gasket. A wide range of corrosion-resistantmaterials ensures that they can beused in metallic tanks containingaggressive liquids.
➅ Probe with gas-tight gland• for liquified gas tanks
(required in Germany)• to prevent condensation forming in
the probe on extreme temperaturevariationsSee also temperature graphsoverleaf.
Probe Versions
C
C
R
A
probe rod
insulation
in air
in material
vessel wall
5
6
4
3
2
1
Simplified circuitdiagram showingcapacitancemeasurement with fullyinsulated probes
3
➆ Probe with temperature spacer• for an extended range of operating
temperatures in the vessel.See also temperature graphs.
➇ Probe without electronic insert• for high temperatures in the probe
housing:Use electronic insert in separatehousing.See also temperature graphs.
➈ Probe with protective cover• (accessory)
to prevent condensation forming inthe aluminium standard housing.
Separate or integrated electronic insert?Information is provided by graphs onthe left.The horizontal axis is the operatingtemperature TB in the vessel. The vertical axis is the ambienttemperature TU of the probe housing(°C).
Do the temperatures lie in the greyarea of graph A?The electronic insert may bemounted in the housing of any probe.
Do the temperatures lie in the greyareas of graph B?The electronic insert may bemounted in the housing of a probewith a temperature spacer orgas-tight gland; or it may bemounted in a separate housing.
Do the temperatures lie in the greyareas of graph C?The electronic insert should bemounted in a separate housing.
Do the temperatures lie in the greyarea of graph D?Use a probe with a temperaturespacer or a gas-tight gland andmount the electronic insert in aseparate housing.
7
8
9
A
B
C
Temperatures Tu and TB
in °C
x °C = ( x .
95
+ 32) °F
– 80 – 40 40 80 120 160
80
40
– 40
TU
TB
200
0
0
– 80 – 40 40 80 120 160
80
40
– 40
TU
TB
200
0
0
– 80 – 40 40 80 120 160
80
40
– 40
TU
TB
200
120
0
0
– 80 – 40 40 80 120 160
80
40
– 40
TU
TB
200
120
160
0
0
D
4
16
25
max. 84
max. 80
G 1 / Aor1 / -11 / NPT
1
1 1
2
2 2
60 AF
appr
ox. 1
35
activ
e pr
obe
rod
prob
e le
ngth
L
16
150
100
25
max. 84
max. 80
G 1 / Aor1 / -11 / NPT
1
1 1
2
2 2
60 AF
appr
ox. 1
35
activ
e pr
obe
rod
prob
e le
ngth
L
max. 84
max. 80
16
appr
ox. 1
60pr
obe
leng
th L
max. 84
max. 80
8
38
appr
ox. 1
5
max. 43
spacer every1000 mm
appr
ox. 1
60pr
obe
leng
th L
16
15010
0
max. 84
max. 80
appr
ox. 1
60
activ
e pr
obe
rod
prob
e le
ngth
L
8
(25)
appr
ox. 3
0(a
ppro
x. 4
0)
15
38
max. 43
max. 80
max. 84
60 AF
spacer every1000 mm
appr
ox. 1
35
activ
e pr
obe
rod
prob
e le
ngth
L
Left:Multicap DC 11with threaded boss
Right:Multicap DC 11with flange
Left:Multicap DC 11with threaded bossG 11/2 Aand ground tube
Dimensions in bracketsare for the threadedboss with 11/2 - 111/2 NPT
Right:Multicap DC 11with flangeand ground tube
Left:Multicap DC 11with threaded bossand active build-upcompensation
Right:Multicap DC 11with flangeand active build-upcompensation
All dimensionsin mm.100 mm = 3.94 in
Dimensions
5
max. 84
max. 80
25
100
150
16
appr
ox. 1
02
max. 43
60 AF
G 1 / Aor1 / -11 /NPT
1
1 1
2
2 2
scre
enin
gL 3
activ
e pr
obe
rod
prob
e le
ngth
L
max. 84
max. 80
25
8
38
appr
ox. 1
02
max. 43
60 AF
L+
app
rox.
8 m
m3
spacer every1000 mm
G 1 / Aor1 / -11 /NPT
1
1 1
2
2 2
scre
enin
gL 3
activ
e pr
obe
rod
prob
e le
ngth
L
max. 84
max. 80
8
38ap
prox
. 120
max. 43
L+
app
rox.
8 m
m3
spacer every1000 mm
scre
enin
gL 3
activ
e pr
obe
rod
prob
e le
ngth
L
max. 84
max. 80
16
appr
ox. 1
20
max. 43 scre
enin
gL 3
activ
e pr
obe
rod
prob
e le
ngth
L
16
25
max. 84
max. 80
appr
ox. 1
02
max. 43
60 AF
G 1 / Aor1 / -11 /NPT
1
1 1
2
2 2
scre
enin
gL 3
activ
e pr
obe
rod
prob
e le
ngth
L
max. 84
max. 80
22
22
appr
ox. 1
60
scre
enin
gL 3
activ
e pr
obe
rod
prob
e le
ngth
L
max. 84
max. 80
16
100
150
appr
ox. 1
20
max. 43 scre
enin
gL 3
activ
e pr
obe
rod
prob
e le
ngth
L
Dimensionsfor Probes withScreening
Top rowfrom left:
Multicap DC 11with PTFE coveredflange and fully insulated screening
Multicap DC 11with threaded bossand screening
Multicap DC 11with flangeand screening
Left:Multicap DC 11with threaded boss,screeningand ground tube
Right:Multicap DC 11with flange,screeningand ground tube
Left:Multicap DC 11with threaded boss,screening andactive build-upcompensation
Right:Multicap DC 11with flange,screening andactive build-upcompensation
All dimensionsin mm.100 mm = 3.94 in
6
• To avoid damage to the probe,remove the packaging on-site justbefore mounting.The uninsulated section of probes withactive build-up compensation iscovered with plastic webbing. Thisprotection should be removed prior tomounting.
• Compare the code on the nameplateof the probe with the productdesignation on Page 10 to ensure thatthe correct probe has been delivered.
• Check the probe length.It is not possible to change the lengthof the probe.
max. 80
max. 80
max. 80
2525
ca.1
59L L
ca. 1
83ca
. 200
(ca.
148)
(ca.
165)
max. 80
max. 80
max. 80
ca.1
60ca
.210
ca.2
25(c
a.16
8)(c
a.18
3)
max. 84
max. 84
max. 84 max. 84
max. 84
max. 84
➀
➁
➂
G 11/2 Aor11/2 - 111/2NPT
G 11/2 Aor11/2 - 111/2NPT
60 AF
60 AF
➀
➁
➂
left:Multicap DC 11with sanitary thread DIN 11851-DN 50
right:Multicap DC 11with 2" Triclampcoupling
left:Multicap DC 11with threaded bossand gas-tight gland
right:Multicap DC 11with flangeand gas-tight gland
left:Multicap DC 11with threaded bossand temperature spacer
right:Multicap DC 11with flangeand temperature spacer
(Dimensions for the DC11 with screening are shown in brackets)
Dimensionsof Other ProcessConnections and Parts
Transport, Unpacking
7
• Probe with parallel thread G 11/2 A:Use the elastomer/fibre seal provided or any other chemically resistant seal which can withstand temperatures up to 300°C (570°F).
• Probe with tapered thread 11/2 - 111/2 NPT:If required, wrap suitable sealingmaterial around the thread.
• Probe with flange connection:Use a sealing material suitable for theapplication.If the flange is PTFE-clad, then this isgenerally a suitable seal up to thepermitted operating pressure.
• Make sure that the probe insulation isnot damaged when sliding the probethrough the threaded sleeve or nozzlewith counter-flange.
• When tightening, turn the probe withthreaded boss at the hex nut only; notat the housing!
• For probes with the G 11/2 A threadand seal:- a torque of only 300 Nm is sufficient to seal tight against a pressure in the vessel of up to 50 bar (725 psi),- a torque of only 530 Nm is sufficient to seal tight against a pressure in the vessel of up to 100 bar (1450 psi),Maximum admissible torque: 600 Nm.
• A polypropylene threaded boss withrubber seal may only be tightenedusing a max. torque of 7 Nm.(1 Nm = 0.74 ft lbs)
Refer to the appropriate TechnicalInformation concerning the electronicinsert EC used in the probe housing.
In the case of the heavy duty housing,the connection diagram corresponds tothat of the built-in electronic insert.
Mounting without electronic insertExchange of electronic inserts• After the defective electronic insert
has been removed and thereplacement properly installed, theinstrument must be recalibrated andchecked for correct function.
Rotating the HousingThe housing can be rotated if the cablegland is pointing in the wrong directionafter mounting.
Standard housing• To loosen:– Unscrew the housing cover– Unscrew the central nut (slotted nut) in the electronic housing– Remove the electronic insert from the housing– Slightly loosen the 3 nuts (7 AF), see Figure.• To rotate:
The housing can now be rotated inany direction.When mounting the probe from theside, the cable entry should be facingdownwards so that no moisture canenter.
• To tighten:– Securely tighten the 3 nuts in the housing so that the housing is tight against the hex nut.– Insert the electronic insert and securely tighten the central nut so that it does not become loose. Ensure that the cable gland remains free.
It is important that no moisture entersthe probe housing during storage of theprobe, connection of the electronicinsert and during operation. Always tighten the housing cover andcable gland securely. If the probe is installed in a plastic tank,connect the ground terminal of theprobe to the counter-electrode using ashort cable.
• If fully insulated multicap probes aremounted in explosion hazardousareas without the electronic insert, andthere is a risk of dangerous electronicdischarges, then the probe terminal inthe housing must be short-circuitedwith the ground terminal.
Installation
Connection
EC 16 Z
1+2 3 4 5 6
6
654321
1
The housing can berotated after the 3nuts have beenloosened
Tighten electronicinsert with thecentral slotted nut
leavingspace for theconnecting cable
Replacing components
8
Technical Data Operating data
• See graphs on the left for therelationship between operatingpressure and temperature.
• Capacitance values of the probeGround capacitance: approx. 30 pF
Other capacitance values:Gas-tight gland: approx. 20 pFTemperature spacer: approx. 20 pFActive build-up compensation: ap-prox. 10 pFScreening: approx. 3 pF/100 mmFully insulated screening: approx. 6 pF/100 mm
Probe 250 mm from a conductive vessel wall:Insulated probe rod: approx. 1.3 pF/100 mm
Probe in ground tube:Insulated probe rod: approx. 5.5 pF/100 mm
• Lateral load bearing capacity of theprobe see Fig. below.
Probe lengths(100 mm = 3.94 in)• Total length of probe:
L max. 6000 mm• Total length of probe with fully
insulated screening: L max. 4000 mm• Length of screening:
L3 min. 100 mm, max. 4000 mm• Length of fully insulated screening: L3
min. 125 mm, max. 2000 mm• Length of active probe rod:
max. 4000 mm• Length of active build-up
compensation: always 150 mm fromwhere the probe rod leaves theprocess connection or screening.
• Length tolerances up to 1 m: +0 mm, - 5 mmup to 3 m: +0 mm, -10 mmup to 6 m: +0 mm, -20 mm
Process connection standards• Parallel thread G 11/2 A:
DIN ISO 228/I, with sealing ring 48 x 55 to DIN 7603
• Tapered thread 11/2 - 111/2 NPT:ANSI B 1.20.1
• DIN flanges: see flange table• ANSI flange: ANSI B 16.5• Sanitary thread: DIN 11851• Triclamp coupling: ISO 2852
MaterialsMost material specifications are given inthe order code on Page 10• Housing: cast aluminium AlSi 12,
resistant to sea water, EP-lacquered • Aluminium housing, coated
in fluoropolymer• Sealing between housing and
process connection: EPDM• Sealing for housing cover:
O-ring in EPDM• Temperature spacer: SS 304 H• Gas-tight gland: SS 304 H• Sealing ring for process connection
G 11/2 A: elastomer/fibre,non-asbestos, resistant to oil, solvents,steam, weak acids and alkalis; up to 300°C and 100 bar (570°F and 1450 psi)
• Cable glands:standard Pg in nickel-plated brasswith NBR seal for cable diameter7...10 mm; Protection IP 55 ; ambienttemperature up to 100°C (210°F)
• Water-tight Pg in polyamide withneoprene/CR seal for cable diameter7...12 mm; Protection IP 66; ambienttemperature up to 80°C (180°F)
See product structure for housingvariations.
without ground tube
with active build-upcompensation
with screening
with screeningand ground tube
with fully insulated screening
with ground tube
with screeningand active build-upcompensation
max. 30 Nm
max. 45 Nm
max. 60 Nm
max. 25 Nm
max. 300 Nm
max. 300 Nm
max. 70 Nm
Lateral load bearingcapacity for the probe at20°C (70°F) and staticload.
1 Nm = 0.74 ft lbs
Permitted operating pressures pe andtemperatures TB
Temperature TB: x °C = ( x . 95
+ 32) °F
Pressure pe: 1 bar = 14.5 psi
TB
pe
bar
100
50 50 100 150 200
80604020
0 °C
20 barbis
1 bar
TB
pe
bar
50
50 50 100 150 200
40302010
0 °C
2 barbis
1 bar
2 barbis
1 bar
TB
pe
bar
°C
20
10
80 60 6040 4020 200
80
4
2
0
–20–1
TB
C0 20
bar
40 60
6
100
pe
0 barbis
1 bar
Probe with polypropylene threadedboss and rubber seal.
Insulation PE
Isulation PTFE or PFAApplies to:- probes with active build-up compensation,- probes with fully insulated screening.
Insulation PTFE or PFADoes not apply to:- probes with active build-up compensation,- probes with fully insulated screening,- Monel.
9
Product Structure
Please state lengths for the probe when ordering.
See also the Figs. on Pages 5 to 7.
Screening Total length of probeL3 L
from the sealing surfaceof the process connection
DC 11 - fully insulated rod probe
Certificates, Approvals Weight (approx.)R Standard Basic weight:A EEx ia IIC T6, Zone 0 2 kgD DIBt, overspill protection WHGF EEx ia IIC T6, Zone 0, overspill protection VbF, WHGG EEx ia IIC T6 (CENELEC)8 For connection to EEx ia
Electronic Insert Additional weight:A None - -B EC 61 0.2 kgC EC 11 0.2 kgD EC 72 0.2 kgE EC 17 Z 0.2 kgF EC 16 Z 0.2 kgG EC 27 Z 0.2 kgH EC 37 Z 0.2 kg I EC 47 Z 0.2 kgY Other
Process Connection / Material See Page 11
Screening Against CondensationA NoneC SS 316 Ti, length L3: 100... 4000 mm 0.2 kg/100 mmD Hastelloy B, length L3: 100…4000 mm 0.2 kg/100 mmE Hastelloy C, length L3: 100…4000 mm 0.2 kg/100 mm F Monel, length L3: 100…4000 mm 0.2 kg/100 mmJ Fully insulated screening, length L3: 125... 2000 mm, 0.1 kg/100 mm
Rod and Screening in SS 316 TiY Other
Active Build-up Compensation For use in metallic vessels only!Active probe rod >500 mm (not with ground tube)1 None - -3 SS 316 Ti, length 150 mm 0.5 kg 4 Hastelloy B, length 150 mm 0.6 kg 5 Hastelloy C, length 150 mm 0.6 kg 6 Monel, length 150 mm 0.6 kg 9 Other
Probe Length L, Material of Rod State total length in mm from the sealing surface Total length L: 100…4000 mmMinimum length L:With active build-up compensation: 650 mmWith screening: 200 mmWith screening and active build-up: 750 mm
A Rod in steel, insulation in PTFE, * 0.1 kg/100 mmB Rod in steel, insulation in PE, * 0.1 kg/100 mmC Rod in steel, insulation in PFA, * 0.1 kg/100 mmD Rod in SS 316 Ti, insulation in PTFE, 0.1 kg/100 mmE Rod SS 316 Ti, insulation in PE, 0.1 kg/100 mmF Rod SS 316 Ti, insulation in PFA, 0.1 kg/100 mmG Rod in Hastelloy B, insulation in PTFE 0.1 kg/100 mmH Rod in Hastelloy B, insulation in PE 0.1 kg/100 mmJ Rod in Hastelloy B, insulation in PFA 0.1 kg/100 mmK Rod in Hastelloy C, insulation in PTFE 0.1 kg/100 mmL Rod in Hastelloy C, insulation in PE 0.1 kg/100 mmM Rod in Hastelloy C, insulation in PFA 0.1 kg/100 mmN Rod in Monel, insulation in PTFE 0.1 kg/100 mmP Rod in Monel, insulation in PE 0.1 kg/100 mmQ Rod in Monel, insulation in PFA 0.1 kg/100 mmY Other
*not with fully insulated screening
Ground tube Material, Length as Probe Length1 None - -2 Ground tube SS 304 H, with steel threaded boss only 0.2 kg/100 mm3 Ground tube in SS 316 Ti 0.2 kg/100 mm4 Ground tube in Hastelloy B 0.2 kg/100 mm5 Ground tube in Hastelloy C 0.2 kg/100 mm6 Ground tube in Monel 0.2 kg/100 mm9 Other
Parts1 Standard, no parts - -2 With temperature spacer 0.5 kg3 With gas-tight gland 0.5 kg9 Other
Housing and Cable Entry See Page 11
Complete product designationDC 11 - Total weight . kg1
10
Product Structure(continued)
Process Connection / MaterialG R 1 Threaded boss G 11/2 A / in steel - -G R 2 Threaded boss G 11/2 A / SS 316 Ti - -G R 4 Threaded boss G 11/2 A / Hastelloy B - -G R 5 Threaded boss G 11/2 A / Hastelloy C - -G R 6 Threaded boss G 11/2 A / Monel - -G R B Threaded boss G 11/2 A / PP - -
G N 1 Threaded boss 1 1/2 - 11 1/2 NPT / in steel - -G N 2 Threaded boss 1 1/2 - 11 1/2 NPT / SS 316 Ti - -G N 4 Threaded boss 1 1/2 - 11 1/2 NPT / Hastelloy B - -G N 5 Threaded boss 1 1/2 - 11 1/2 NPT / Hastelloy C - -G N 6 Threaded boss 1 1/2 - 11 1/2 NPT / Monel - -
M E 2 Sanitary thread DN 50 / SS 304 H, not with ground tube 0.5 kgT E 2 Triclamp coupling, 2" (ISO 2852) / SS 304 H, not with ground tube 0.5 kg
B G 1 Flange conf. to DIN 2527, Form B, without sealing strip, DN 50, PN 40 / in steel 3.0 kgB G 2 Flange conf. to DIN 2527, Form B, without sealing strip, DN 50, PN 40 / SS 316 Ti 3.0 kgB G 3 Flange conf. to DIN 2527, Form B, without sealing strip, DN 50, PN 40 / SS 316 Ti coated with PTFE 3.0 kg
B M 1 Flange conf. to DIN 2527, Form B, without sealing strip, DN 80, PN 16 / in steel 4.5 kgB M 2 Flange conf. to DIN 2527, Form B, without sealing strip, DN 80, PN 16 / SS 316 Ti 4.5 kgB M 3 Flange conf. to DIN 2527, Form B, without sealing strip, DN 80, PN 16 / SS 316 Ti coated with PTFE 4.5 kg
B Q 1 Flange conf. to DIN 2527, Form B, without sealing strip, DN 100, PN 16 / in steel 5.4 kgB Q 2 Flange conf. to DIN 2527, Form B, without sealing strip, DN 100, PN 16 / SS 316 Ti 5.4 kgB Q 3 Flange conf. to DIN 2527, Form B, without sealing strip, DN 100, PN 16 / SS 316 Ti coated with PTFE 5.4 kg
C G 2 Flange conf. to DIN 2526, Form C, with sealing strip, DN 50, PN 40 / SS 316 Ti 3.0 kgC G 4 Flange conf. to DIN 2526, Form C, with sealing strip, DN 50, PN 40 / SS 316 Ti coated with Hastelloy B 3.2 kgC G 5 Flange conf. to DIN 2526, Form C, with sealing strip, DN 50, PN 40 / SS 316 Ti coated with Hastelloy C 3.2 kgC G 6 Flange conf. to DIN 2526, Form C, with sealing strip, DN 50, PN 40 / Monel 3.2 kg
C M 2 Flange conf. to DIN 2526, Form C, with sealing strip, DN 80, PN 16 / SS 316 Ti 4.5 kgC M 4 Flange conf. to DIN 2526, Form C, with sealing strip, DN 80, PN 16 / SS 316 Ti coated with Hastelloy B 4.8 kgC M 5 Flange conf. to DIN 2526, Form C, with sealing strip, DN 80, PN 16 / SS 316 Ti coated with Hastelloy C 4.8 kgC M 6 Flange conf. to DIN 2526, Form C, with sealing strip, DN 80, PN 16 / Monel 4.8 kg
C Q 2 Flange conf. to DIN 2526, Form C, with sealing strip, DN 100, PN 16 / SS 316 Ti 5.4 kgC Q 4 Flange conf. to DIN 2526, Form C, with sealing strip, DN 100, PN 16 / SS 316 Ti coated with Hastelloy B 5.8 kgC Q 5 Flange conf. to DIN 2526, Form C, with sealing strip, DN 100, PN 16 / SS 316 Ti coated with Hastelloy C 5.8 kgC Q 6 Flange conf. to DIN 2526, Form C, with sealing strip, DN 100, PN 16 / Monel 5.8 kg
F G 2 Flange conf. to DIN 2512, Form F, with spring, DN 50, PN 40 / SS 316 Ti 3.0 kgF M 2 Flange conf. to DIN 2512, Form F, with spring, DN 80, PN 16 / SS 316 Ti 4.5 kgF Q 2 Flange conf. to DIN 2512, Form F, with spring, DN 100, PN 16 / SS 316 Ti 5.4 kg
N G 2 Flange conf. to DIN 2512, Form N, with groove, DN 50, PN 40 / SS 316 Ti 3.0 kgN M 2 Flange conf. to DIN 2512, Form N, with groove, DN 80, PN 16 / SS 316 Ti 4.5 kgN Q 2 Flange conf. to DIN 2512, Form N, with groove, DN 100, PN 16 / SS 316 Ti 5.4 kg
A E 1 Flange conf. to ANSI, RF, 2", 150 psi / steel 1.6 kgA E 2 Flange conf. to ANSI, RF, 2", 150 psi / SS 316 Ti 1.6 kgA E 3 Flange conf. to ANSI, RF, 2", 150 psi / SS 316 Ti coated with PTFE 1.6 kgA E 4 Flange conf. to ANSI, RF, 2", 150 psi / SS 316 Ti coated with Hastelloy B 1.8 kgA E 5 Flange conf. to ANSI, RF, 2", 150 psi / SS 316 Ti coated with Hastelloy C 1.8 kgA E 6 Flange conf. to ANSI, RF, 2", 150 psi / Monel 1.8 kg
AG 2 Flange conf. to ANSI, RF, 2", 300 psi / SS 316 Ti 3.0 kg
A L 1 Flange conf. to ANSI, RF, 3", 150 psi / steel 3.2 kgA L 2 Flange conf. to ANSI, RF, 3", 150 psi / SS 316 Ti 3.2 kgA L 3 Flange conf. to ANSI, RF, 3", 150 psi / SS 316 Ti coated with PTFE 3.2 kg
A N 2 Flange conf. to ANSI, RF, 3", 300 psi / SS 316 Ti 5.6 kg
A P 1 Flange conf. to ANSI, RF, 4", 150 psi / steel 5.4 kgA P 2 Flange conf. to ANSI, RF, 4", 150 psi / SS 316 Ti 5.4 kgA P 3 Flange conf. to ANSI, RF, 4", 150 psi / SS 316 Ti coated with PTFE 5.4 kgA P 4 Flange conf. to ANSI, RF, 4", 150 psi / SS 316 Ti coated with Hastelloy B 5.8 kgA P 5 Flange conf. to ANSI, RF, 4", 150 psi / SS 316 Ti coated with Hastelloy C 5.8 kgA P 6 Flange conf. to ANSI, RF, 4", 150 psi / Monel 5.8 kg
A R 2 Flange conf. to ANSI, RF, 4", 300 psi / SS 316 Ti 7.3 kg
K F 1 Flange conf. to JIS, RF, 20 K 50 / steel 2.6 kgK F 2 Flange conf. to JIS, RF, 20 K 50 / SS 316 Ti 2.6 kgK F 4 Flange conf. to JIS, RF, 20 K 50 / SS 316 Ti coated with Hastelloy B 2.8 kgK F 5 Flange conf. to JIS, RF, 20 K 50 / SS 316 Ti coated with Hastelloy C 2.8 kgK F 6 Flange conf. to JIS, RF, 20 K 50 / Monel 2.8 kg
Y Y 9 Other
1 kg = 2.2 lbs
Product designation for process connection Add. weight . kg
Housing and Cable Entry
Standard housingA Aluminium (IP 66), Pg 16 (IP 55) - -B Aluminium (IP 66), Pg 16 (IP 66) - -C Aluminium (IP 66), 1/2 - 14 NPT - -D Aluminium (IP 66), G 1/2 - -
E Aluminium (IP 66), M 20 x 1.5 - -F Aluminium (IP 66), HNA 24 x 1.5 - -K Polyester (IP 66), Pg 16 (IP 66) - -L Polyester (IP 66), 1/2 - 14 NPT - -M Polyester (IP 66), G 1/2 - -O Polyester (IP 66), M 20 x 1.5 - -P Polyester (IP 66), HNA 24 x 1.5 - -R Aluminium, coated (IP 66), Pg 16 (IP 66) - -T Aluminium, coated (IP 66), 1/2 - 14 NPT - -U Aluminium, coated (IP 66), G 1/2 - -V Aluminium, coated (IP 66), M 20 x 1.5 - -W Aluminium, coated (IP 66), HNA 24 x 1.5 - -S Stainless steel (IP 66), Pg 16 (IP 66) 0.7 kgJ Stainless steel (IP 66), HNA 24 x 1.5 0.7 kg
Product designation Add. weight kg for housing
11
Accessories • Protective cover for the probehousing
Electronic insert EC 11, EC 72Technical Information TI 270F/00/enElectronic insert EC 16 ZTechnical Information TI 170F/00/enElectronic insert EC 17 ZTechnical Information TI 268F/00/enElectronic insert EC 37 Z, EC 47 ZTechnical Information TI 271F/00/en
Certificate of conformity (CENELEC)Certificate ZE 224F/00/a2Certificate of conformity with Germannational appendix and type approvalfor level limit switch, continuous levelmeasurement and overspillprotection to VbF (for Germany)Certificate ZE 212F/00/de
Product designationLength of screening, and complete probeSpecial version if required
see Technical Information "Probe accessories"
Electronic insert EC 61 ZTechnical Information TI 267F/00/enProbe accessoriesTechnical Information TI 229F/00/enSeparate housing for electronic insertTechnical Information TI 228F/00/enTransmitters for limit detection andcontinuous level measurement onrequest
DIBt test report to § 19 WHG foroverspill protection with level limitswitch (for Germany)Certificate ZE 211F/00/deDIBt test report to § 19 WHG foroverspill protection with continuouslevel measurement (for Germany)Certificate ZE 210F/00/de
Accessories, e.g. – Protective cover, – separate housing for the electronic insert (probe housing only with cable entry Pg 16)
Certificates
Order Details