mucool test area rf workshop 111/15/2010 muons, inc. loaded pillbox cavity milorad popovic &...
Post on 22-Dec-2015
220 views
TRANSCRIPT
MuCool Test Area RF Workshop111/15/2010
Muons, Inc.
Loaded Pillbox CavityMilorad Popovic
&
Katheryn Decker French
(with Mike, Chuck, Katsuya, Al and Rol)
Motivation
MuCool Test Area RF Workshop 211/15/2010
Muons, Inc.
To fit pressurized cavities in HCC, size of cavity has to be reduced800 MHz (from Katsuya)
Maximum RF cavity radius = 0.08 m, (pillbox cavity 0.143)Radius of effective electric field (95 % from peak) = 0.03 m
400 MHz:Maximum RF radius = 0.16 m (pillbox cavity 0.286) Radius of effective electric field = 0.06 mOptimum electric field gradient = 16 MV/m
rrR
c
405.2
For Pill Box Cavity, resonant frequency is
Other Applications
MuCool Test Area RF Workshop 311/15/2010
Muons, Inc.
May be we can use this type of cavity for Neuffer’s Phase Rotation Canal. This was Cary Yoshikawa suggestion. The canal needs many cavities in range from ~300 to 200MHz. We can use, let say two sizes of Pill Box Cavity (same size different dielectric!) and adjust frequency in between using different iner radius, re-entrant nose cones!
Cavities for Neutrino Factory
MuCool Test Area RF Workshop 411/15/2010
Schematic of the Neutrino Factory front-end transport system. Initial drift (56.4 m), the varying frequency buncher (31.5m), The phase-energy (-E) rotator (36m) , a cooling section.(A 75m cooling length may be optimal.)
Parameter Drift Buncher Rotator Cooler
Length (m) 56.4 31.5 36 75
Focusing (T) 2 2 2 2.5 (ASOL)
Rf frequency (MHz) 360 to 240 240 to 202 201.25
Rf gradient (MV/m) 0 to 15 15 16
Total rf voltage (MV) 126 360 800
MuCool Test Area RF Workshop 511/15/2010
Work done in Summer 2010
MuCool Test Area RF Workshop 611/15/2010
Simulation-Microwave Studio
MuCool Test Area RF Workshop 711/15/2010
Cavity Prototype & Measurements
MuCool Test Area RF Workshop 811/15/2010
Results & Conclusions as August 2010
MuCool Test Area RF Workshop 911/15/2010
Muons, Inc. Near Future Possibilities
•Build high power 800MHz cavity with Dielectric at Gap•Modify it for use with Dielectric Liquid•Put it inside Solenoid Magnet•Do the same for 200MHz
This program can be executed for 20 to 40K$ M&SThis program can be accomplished in 4 to 8 monthsThere will be need for two periods of one week each of MTA Muons, Inc has expressed interests in participation, intellectually and monetaryWe may be lucky and motivate somebody to put effortin low loss ceramics research and designHelp is need it and everybody is welcome
MuCool Test Area RF Workshop 1011/15/2010
Muons, Inc. Ceramics for 200MHz & cavity for 800MHz
MuCool Test Area RF Workshop 1111/15/2010
RF
Solenoid
DielectricLiquid
Container
Solenoid, Cavity, Liquid, …
cavity
MuCool Test Area RF Workshop 211/15/2010
Muons, Inc.
MuCool Test Area RF Workshop 211/15/2010
Muons, Inc.
HCC Concept
Muon Collider Design Workshop, Jefferson Lab 1412/09/2008
Muons, Inc.
Central Orbit and Beam Envelope Set of Coils
Basic Building Blockcan be Cavity + Coils
80GeVLinac
80GeVLinac
ColliderRing
mAcceleration