mua webinar 092413 - noanimations · kitchen exhaust designing and installing for ... outdoor air...

29
Make MakeUp Air for Residential Up Air for Residential Make MakeUp Air for Residential Up Air for Residential Kitchen Exhaust Kitchen Exhaust Designing and Installing for Designing and Installing for Designing and Installing for Designing and Installing for Code Compliance Code Compliance

Upload: others

Post on 25-Sep-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

MakeMake‐‐Up Air for ResidentialUp Air for ResidentialMakeMake‐‐Up Air for Residential Up Air for Residential Kitchen ExhaustKitchen Exhaust

Designing and Installing forDesigning and Installing forDesigning and Installing for Designing and Installing for Code ComplianceCode Compliance

Page 2: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

What We’ll CoverWhat We’ll CoverWhat We ll CoverWhat We ll Cover

• Background• Code requirementsCode requirements• Gravity dampers• Installation options• Design and live demoDesign and live demo

Make‐Up Air for Domestic Range Hood Exhaust 1

Page 3: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

What is MakeWhat is Make up Air (MUA)?up Air (MUA)?What is MakeWhat is Make‐‐up Air (MUA)?up Air (MUA)?

Makeup air: Outdoor air and transfer air used to replace exhaust airused to replace exhaust air

Outdoor air: Air that enters a building gthrough a ventilation system, through intentional openings or by infiltrationintentional openings … or by infiltration.

Make‐Up Air for Domestic Range Hood Exhaust 2

Page 4: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

How does MUA Flow into the Dwelling?How does MUA Flow into the Dwelling?How does MUA Flow into the Dwelling?How does MUA Flow into the Dwelling?

Intentional  Existing cracks or openings (i.e., an outdoor air duct ith d )

gaps in the building envelope

with a damper)

Make‐Up Air for Domestic Range Hood Exhaust 4

Page 5: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

How does MUA Flow into the Dwelling?How does MUA Flow into the Dwelling?How does MUA Flow into the Dwelling?How does MUA Flow into the Dwelling?

Intentional  Existing cracks or openings (i.e., an outdoor air duct ith d )

gaps in the building envelope

with a damper)

Make‐Up Air for Domestic Range Hood Exhaust 5

Page 6: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Provide MUA ToProvide MUA ToProvide MUA To…Provide MUA To…

Meet code requirementsq

M i i d i d i li b idiMaintain good indoor air quality by avoiding excessive depressurization during operation of exhaust appliancesof exhaust appliances

Enable exhaust hood to function as designed

Make‐Up Air for Domestic Range Hood Exhaust 6

Page 7: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Max Recommended DepressurizationMax Recommended DepressurizationMax Recommended DepressurizationMax Recommended Depressurization

5 15 50

Make‐Up Air for Domestic Range Hood Exhaust 7

Page 8: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

MUA CodeMUA Code RequirementsRequirementsMUA Code MUA Code RequirementsRequirements

  

Make‐Up Air for Domestic Range Hood Exhaust 8

Page 9: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

MUA CodeMUA Code RequirementsRequirementsMUA Code MUA Code RequirementsRequirements

• When: Exhaust rate > 400 cfm• HowMuch: “approximately equal to exhaust”How Much:  approximately equal to exhaust• Include: “a means of closure automatically 

ll d d i l lcontrolled to start and operate simultaneously with the exhaust system”

IRC: 2009 and 2012 Section M1503 4IRC: 2009 and 2012 Section M1503.4IMC: 2009 and 2012 Section 505.2

Make‐Up Air for Domestic Range Hood Exhaust 9

Page 10: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Gravity Dampers: Why Not?Gravity Dampers: Why Not?Gravity Dampers: Why Not?Gravity Dampers: Why Not?

N t d b d• Not approved by code • Are not “automatically controlled” per IRC M1503 4M1503.4

M l diff i l• May not open at low pressure differentials

• May not address back‐drafting issue

• Specify motorized makeup air damper at a minimum

Make‐Up Air for Domestic Range Hood Exhaust 10

Page 11: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Gravity DampersGravity DampersGravity DampersGravity Dampers

Contractor‐made gravity damper, actual install in 2000.  Notice the canvas hinge (below) attached with rivets (left).

Make‐Up Air for Domestic Range Hood Exhaust 11

Page 12: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Gravity DampersGravity DampersGravity DampersGravity Dampers

• IRC  2015 Public Comment Hearings

• Atlantic City, NJ: Oct 3‐8, 2013

• Registered Code Officials can Vote!Registered Code Officials can Vote!• Disapprove  RM34 (gravity dampers) • Approve RM31 or RM35 (motorized dampers)

Make‐Up Air for Domestic Range Hood Exhaust 12

Page 13: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

MUA Is Recommended ForMUA Is Recommended ForMUA Is Recommended For…MUA Is Recommended For…

Large range hoods (those

Newer energy efficient “tight”

Dwellings with indoor naturalhoods (those 

over 300 cfm)efficient,  tight  

or “green” dwellings that are well air

indoor natural draft combustion 

appliancesare well air‐

sealed

Make‐Up Air for Domestic Range Hood Exhaust 13

Page 14: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

INSTALLATION CONFIGURATIONS

Page 15: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Installation Option 1Installation Option 1Installation Option 1Installation Option 1

1. Interlock t l f ithcentral fan with MUADMUAD  

Hood On

MUAD Open

Central Fan On

Permitted by IRC Section M1602.1

Make‐Up Air for Domestic Range Hood Exhaust

y

15

Page 16: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Installation Option 2Installation Option 2Installation Option 2Installation Option 2

2. No interlock between MUAD and central fanand central fan  

Hood On

MUAD Open

Permitted by IRC Section M1602.1

Make‐Up Air for Domestic Range Hood Exhaust

y

16

Page 17: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Installation Option 3Installation Option 3Installation Option 3Installation Option 3

3 Routed to3. Routed to interior registerg

Hood On

MUAD Open

Make‐Up Air for Domestic Range Hood Exhaust 17

Page 18: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Installation Option OverviewInstallation Option OverviewInstallation Option OverviewInstallation Option Overview

System Code Compliant? Tempers MUA Circulates MUA

Make‐Up Air for Domestic Range Hood Exhaust 18

Page 19: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Outdoor Air Intake LocationOutdoor Air Intake LocationOutdoor Air Intake LocationOutdoor Air Intake Location

¼” – ½” screen: IRC 303.6

Minimum 1 foot and clear of snow and debris: IRC 303.5

MUA ducts should not draw air from crawlspaces, garages, attics, adjacent dwelling units, or any enclosed part of the building: IRC 303.5.2

Make‐Up Air for Domestic Range Hood Exhaust 19

Page 20: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

MAKE‐UP AIR THEORY

Page 21: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

ConsiderationsConsiderations C b tiConsiderationsConsiderations Combustion Appliance Types

MUA  Air Tightness Kitchen Exhaust Rate

Solution of DwellingExhaust Rate (Actual)

Damper Installation 

Configuration

Make‐Up Air for Domestic Range Hood Exhaust 21

Page 22: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Governing EquationsGoverning EquationsGoverning EquationsGoverning Equations

Darcy‐Weisbach 212

VCfLp

H l d

1097

CD

p

2 Haaland 211.1

Re9.6

7.3log8.1

Df

ASHRAE Fundamentals

np

r

rrr p

pQQ

1,

2,1,2,

Make‐Up Air for Domestic Range Hood Exhaust 22

Page 23: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

DESIGN

Page 24: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Using Broan/BEST’s MUA Specifier ToolUsing Broan/BEST’s MUA Specifier ToolUsing Broan/BEST s MUA Specifier ToolUsing Broan/BEST s MUA Specifier Tool

St t l l d Cli t

Outputs supplied by the Range Hood MUAOutputs supplied by the Range Hood MUA SpecifierSpecifier include…include…

State level code requirements

Climate considerations

Design exhaust rate

Dwelling leakage at design 

d i tidepressurization

Flow throughFlow through automatic MUA 

dampers

Make‐Up Air for Domestic Range Hood Exhaust 24

Page 25: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Broan/BEST MUA Specifier Tool Broan/BEST MUA Specifier Tool DemonstrationDemonstration

Access via Access via Internet: Internet: www.broan.comSelect: “Specifier Tools” from top toolbarSelect: “Specifier Tools” from top toolbar

Select: “MakeSelect: “Make‐‐Up Air Damper Tool” from left toolbarUp Air Damper Tool” from left toolbar

Make‐Up Air for Domestic Range Hood Exhaust 25

Page 26: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Q & AQ & AQ & AQ & A

Need BPI or AIA credits? Contact: sbowles@newportventures netContact: [email protected]

Make‐Up Air for Domestic Range Hood Exhaust 26

Page 27: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Bonus Bonus Slides: Slides: NNot Included in Original Webinarot Included in Original Webinar

Make‐Up Air for Domestic Range Hood Exhaust 27

Page 28: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Climate ConsiderationsClimate ConsiderationsClimate  ConsiderationsClimate  Considerations

Cold If integrating with a furnaceCold climate zones

If integrating with a furnace, pre‐heating the outdoor MUA may be necessary.

Humid Wh h d lli i i liHumid climates

When the dwelling is in cooling mode, operation of the AC and/or a supplementary dehumidification system shoulddehumidification system should be considered.

Make‐Up Air for Domestic Range Hood Exhaust 28

Page 29: MUA webinar 092413 - NoAnimations · Kitchen Exhaust Designing and Installing for ... Outdoor Air Intake Location ¼” –½” screen: IRC 303.6 Minimum 1 foot and clear of snow

Limits to MUA in Furnace Return DuctLimits to MUA in Furnace Return DuctLimits to MUA in Furnace Return DuctLimits to MUA in Furnace Return Duct

Climate Zone

MaxRecommended OA Flow

as % of Total FurnaceZone as % of Total Furnace Air Handler Flow

1 No limit*2 60%3 40%4 35%4 35%5 25%6 20%

*But be reasonable!  

Make‐Up Air for Domestic Range Hood Exhaust 29