mspi driving safer nuclear power plant – callaway energy center hongbing jiang tennessee valley...
TRANSCRIPT
![Page 1: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/1.jpg)
1
MSPI DRIVING SAFER NUCLEAR POWER PLANT –
CALLAWAY ENERGY CENTER
Hongbing Jiang Tennessee Valley Authority
Zhiping Li Ameren Missouri
![Page 2: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/2.jpg)
2
I. INSTRUCTION II. WHAT IS MSPI III. MSPI APPLICATION: A CASE STUDY III.A. Power Source Design III.B. Extra Decay Heat Removal Design III.C. Observations and Areas For
Improvement IV. MSPI OPTIMIZATION V. CONCLUSIONS
Outlines
![Page 3: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/3.jpg)
3
MSPI (Mitigating System Performance Index) assessing licensee performance.
Regulation : NRC ROP with Action Matrix
MSPI could reflect implicitly or explicitly the as-built, as-operated, as-maintained and as-planned plant with the predefined baselines,
MSPI driving safer NPP – Callaway Energy Center
I. INSTRUCTION
![Page 4: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/4.jpg)
4
Widely recognized Equation
UAI : Unavailability Index URI : Unreliability Index
NUREG-1816, NEI 99-02
II. WHAT IS MSPI
![Page 5: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/5.jpg)
5
Where:; Numeric Index (NI) Performance Limit Exceed (PLE)
II. WHAT IS MSPI
![Page 6: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/6.jpg)
6
II. WHAT IS MSPI
MSPI
NI
Non-Green (True)
Green(False)
Non-Green(True) (NI=T, MSPI=T)
(NI=T, MSPI=F)& RiskCap
Green(False)
(NI=F, MSPI=T)
& PLE(NI=F, MSPI=F)
Actual State
Indication State
True False
True (T, T) (T, F)
False (F, T) (F, F)
Truth Table of Recognition Overall View of MSPI
![Page 7: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/7.jpg)
7
In 2010, Callaway Nuclear Power Plant (4-loop, W-PWR, 3565 MWt)
(1) white for an EAC system (2) potential white for AFW system
Installed AEPS and motor-driven NSAFP modifications were completed in 2011
Safer nuclear power plantCDF was reduced to about half
before the Japanese FukushimaINPO 1 “excellent” rating
III. MSPI APPLICATION: A CASE STUDY
![Page 8: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/8.jpg)
8
Design features
Switchyard vs. Safety Bus SBO considerationLOOP consideration
III.A. Power Source Design
![Page 9: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/9.jpg)
9
SBO mitigation
Pump location reduced margin due to steam break initiator
III.B. Extra Decay Heat Removal Design
![Page 10: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/10.jpg)
10
time consuming to input data (text XML input) Only integer margins (decimal margin index) Only the maximum margin (margin combination)
threshold 1.05E-6 (1.00E-6) Excessively high UA hours (below 36 months) Shorter MT, more EAC FTR margin gain the margin one system, lose margin
another system Selection of low risk significant (≤1.0E-6)
components
III.C. Observations and Areas for Improvement
![Page 11: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/11.jpg)
11
The software, MSPI Analyzer, developed for MSPI application and optimization
III.C. Observations and Areas For Improvement
![Page 12: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/12.jpg)
12
“RISK WORTH” (X), which measures the risk increase in terms of CDF or MSPI change from one unavailability hour or one unreliability failure.
Potential MR, SDP applications (X, Birnbaum)
IV. MSPI OPTIMIZATION
![Page 13: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/13.jpg)
13
IV. MSPI OPTIMIZATION
The MSPI optimization function:
![Page 14: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/14.jpg)
14
IV. MSPI OPTIMIZATION
Given (1) PRA parameters like CDF, FV, CCF, (2) operational data such as critical hours, estimated or actual component run time and demands and industry and plant specific baseline values,
The GREEN MSPI combination can be determined in advance.
![Page 15: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/15.jpg)
15
IV. MSPI OPTIMIZATION
(A)TRNA.X
(B)TRNB.X
(C) *DG.Xs
(D) *DG.Xl
(E) *DG.Xr
X 1.534E-09 1.534E-09 6.639E-07 6.528E-07 2.593E-06
Then the corresponding object function is
1.534E-09*A +1.534E-09*B + 6.639E-07*C + 6.528E-07*D + 2.593E-06*E <= 3.362E-06
TABLE III. Train Unavailability and Component Group Unreliability Risk Worth
![Page 17: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/17.jpg)
17
IV. MSPI OPTIMIZATION
Maximization of EAC Green Margin
![Page 18: MSPI DRIVING SAFER NUCLEAR POWER PLANT – CALLAWAY ENERGY CENTER Hongbing Jiang Tennessee Valley Authority Zhiping Li Ameren Missouri 1](https://reader031.vdocuments.site/reader031/viewer/2022020320/56649e7e5503460f94b81bc3/html5/thumbnails/18.jpg)
18
MSPI reflects implicitly or explicitly the as-built, as-operated, as-maintained and as-planned Nuclear Power Plants (NPP).
Overall, the MSPI index is not only able to, but also it can be the index for selecting better plant designs and.
Once the PRA and plant data are known, all green combinations can be determined in advance.
Better MSPI means safer plant operation, a plant is able to predefine strategy and make proactive decisions rather than response passively.
V. CONCLUSIONS