mri infusion pump group members: aman ghotra – team leader can pi – communicator miguel benson -...

18
MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D. Frank Hospod Advisor:

Upload: jayson-porter

Post on 31-Dec-2015

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

MRI INFUSION PUMP

Group Members:Aman Ghotra – Team LeaderCan Pi – CommunicatorMiguel Benson - BSACPrakash Rao – BWIG

Client: Dr. George Newman, Ph.D.Frank Hospod

Advisor: John Webster, Ph.D.

Page 2: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

University of Wisconsin - MadisonBiomedical Engineering Design Courses

INTELLECTUAL PROPERTY STATEMENT

All information provided by individuals or Design Project Groups during this orsubsequent presentations is the property of the University and of the researcherspresenting this information. In addition, any information provided herein mayinclude results sponsored by and provided to a member company of theBiomedical Engineering Student Design Consortium (SDC). The above informationmay include intellectual property rights belonging to the University to which theSDC may have license rights.

Anyone to whom this information is disclosed:

1) Agrees to use this information solely for purposes related to this review;

2) Agrees not to use this information for any other purpose unless given writtenapproval in advance by the Project Group, the Client / SDC, and the Advisor.

3) Agrees to keep this information in confidence until the University and therelevant parties listed in Part (2) above have evaluated and secured anyapplicable intellectual property rights in this information.

4) Continued attendance at this presentation constitutes compliance with thisagreement.

Page 3: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

OUTLINE

• Problem Statement• Client’s Requirements• Designs 1-3

– Spur Gear– Vane Pump– Peristaltic Pump

• Decision Matrix• Stepping Motor• Design Proposal• Future Goals

Page 4: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

PROBLEM STATEMENT

• Current MRI compatible infusion pumps are syringe-driven

• Limitations:

a. Flexibility in programming

b. Saline and gadolinium capacities (60 mL and 60 mL, respectively)

c. Time Consuming (~7 min)

www.medrad.com

Page 5: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

CLIENT REQUIREMENTSThe pumps must:

•Be made of a non-ferrous material•Minimize gadolinium or saline waste•Deliver accurate flow rates

• (0.2-4 mL/s, ± 0.02 mL/s)•Be easily sterilized and durable•Be programmable

•Sequence: saline→bolus →saline →infusion →saline

•Manage time to produce consistent images•Attach to containers (60/180 mL)

Page 6: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

SPUR GEAR PUMP

• A pair of matched gears rotate in opposite directions.

• The air pockets created by the rotating gears draw in the liquids.

• The fluid exit at the outlet of the gear.

http://www.mech.uwa.edu.au/DANotes/gears/meshing/meshing.html#top

Page 7: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

PROS & CONS

PROS

•Low cost•Simple•Reliable•Efficient

CONS

•Hard to sterilize•Sanitizing solution•Replacement

Page 8: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

VANE PUMP

http://www.animatedsoftware.com

Page 9: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

VANE PUMP (cont.)

•Cost

•Varies greatly

•$174 - $2993

•Parts

•Rotor

•Vane plates

•Casing

http://www.animatedsoftware.com/

Page 10: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

PROS AND CONS

Pros

• Develops good vacuum

• Good with thin liquids

• Can change displacement and angle

Cons

• Complex

• Not for thick liquids

• Contamination possible

• Hard to Clean

Page 11: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

PERISTALTIC PUMPS

• Flow rate controlled by roller clamp

• Tube walls squeezed to form seal as roller moves along tube– More rollers

increase accuracy

http://www.animatedsoftware.com/pumpglos/peristal.htm

Page 12: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

PERISTALTIC PUMPS (cont.)

• Positive Displacement Pump

• Used in a variety of medical applications

http://www.pump-manufacturers.com/suppliers/environmentalpumping.html

Page 13: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

PERISTALTIC PUMPS (cont.)

• Accuracy decreases as tubing wears and loses flexibility

• BUT, tubing will be changed after every patient

• Very sterile – no external contact with fluid• Typical price range: $170+

http://www.uspto.gov/

Page 14: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

Maintenance Efficiency Cost Accessibility Total

Spur Gear Pump

1 2 3 2 8

Vane Pump

1 3 1 1 6

Peristaltic Pump

3 3 2 3 11

DESIGN EVALUATION

0 – worst; 3 - best

Page 15: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

STEPPING MOTORS

• Converts electrical energy into motion

• Characteristics:– Voltage = Torque

– Low cost ($60 & up)

– Easily programmable• C/C++ Program• Labview

http://eio.com/step-rot.html

Page 16: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

DESIGN PROPOSAL

Alternative:

If we can’t find out how to deshield the pump/motor case:

We will have the motor in the control room and connect this with the rest of the apparatus through the wall.

Page 17: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

• Work on budget with client

• Buy parts to assemble pump

• Buy an economical Stepper Motor

• Learn programming

• Figure out deshielding options/nonferrous materials

FUTURE GOALS

Page 18: MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader Can Pi – Communicator Miguel Benson - BSAC Prakash Rao – BWIG Client: Dr. George Newman, Ph.D

Questions?