mould in buildings new plymouth conference – november 2013 philip o’sullivan, director

20
MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Upload: colleen-porcher

Post on 15-Dec-2015

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

MOULD IN BUILDINGS

New Plymouth Conference – November 2013

Philip O’Sullivan, Director

Page 2: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Typical Buildings Affected

• Residential

• Educational

• Healthcare

• Accommodation

• Offices

Page 3: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

All You Need Is:

Dampness Cellulose

SporesAir

Page 4: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Cellulose is common in many building products:

• Timber

• Reconstituted wood panels e.g. particle board

• Plasterboard (paper faced)

• Kraft-based building papers e.g. black building paper

• Fibre cement e.g. Hardiflex

• Carpet with jute backing

Page 5: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

And in all types of construction:

• Light timber framed

• Light steel framed

• Reinforced concrete masonry

• Reinforced concrete

• Structural Steel

Page 6: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Typical causes of dampness

• Leaking roofs

• Leaking walls

• Plumbing leaks

• Air-conditioning – condensate drain leaks

• Subfloor dampness – often poor ventilation

• Flooding

Page 7: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Reinforced Concrete Masonry

Page 8: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Inside View

Page 9: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Steel Framing

Page 10: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Timber Framing

Page 11: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Symptoms

• Health issues (Adrienne to discuss)

• Internal evidence of mould in walls – not common

• Most often no obvious symptoms

Page 12: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Best to obtain information BEFORE remediation commences

• Sample collection - Adrienne to explain

• Prendos prefers air sampling – helpful diagnostic tool

• AVOID removing internal linings - if no choice then cover and seal opening

Page 13: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Diagnostic Techniques

Example from air sampling in concrete building with light steel framed walls.

Colour coded to mould type and anticipated level of dampness.

Page 14: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Comparing spore levels with possible levels of dampness

Retaining Wall Leak

Balcony Leaks

Damp subfloor

Page 15: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Options if high spore levels encountered:

• Eliminate –takes time to remediate

• Isolate – only if parts of building can be closed and sealed off

• Minimise – improve ventilation or use recirculating air filters

• Fixing or preventing the leak, without mould removal, often

leads to increased spore levels.

• Need to undertake on-going air testing if building is to remain

occupied.

Page 16: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Remediation - localised

• If leak localised then possible to seal off affected area and remediate.

• Need H&S plan

• Provide negative pressure – extract fan to outside

• Provide separate access from outside to prevent contamination

• Check spore levels after decontamination and re-clean if necessary.

• Check again as may have missed some contaminated material.

Page 17: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Remediation - global• If leakage affecting a substantial part, or all of building then

usually best for occupants to vacate during repairs.

• If mould in external walls then leave lining on, remove cladding and remove other materials while damp.

• If mould from located internally (roof or services leak):

1. Provide negative pressure – extract fan to outside.

2. Remove mould affected material.

3. Check spore levels after decontamination and re-clean if necessary.

4. Recheck as may have missed some contaminated material.

Page 18: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Severely decayed timber and mould spore levels were very high

Page 19: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Decayed untreated timber, very limited mould growth.

Page 20: MOULD IN BUILDINGS New Plymouth Conference – November 2013 Philip O’Sullivan, Director

Thank You