montageanleitung - herbert burda · pdf fileting on burda carcass set. consists of: electronic...

16
Montageanleitung elektrische Urinal-Steuerung BurdaTronic U-01 / U-02

Upload: trinhdung

Post on 07-Feb-2018

220 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Montageanleitungelektrische Urinal-Steuerung BurdaTronic U-01 / U-02

Page 2: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Berührungslose Infrarot-Einzelurinalsteuerung. Bedarfs-abhängige Vorspülung, einstellbare Hauptspülung sowie Hygienespülung bei 24 Stunden Nichtbenutzung. Zur Fertigmontage passend auf Burda Rohbauset.

Bestehend aus:Elektronikplatte mit integriertem Netzteil, Montage-rahmen und Magnetventil.Die Montage und Installation darf nur durch einen

konzessionierten Fachbetrieb, gemäß DIN 1988 sowie VDE 0100 Teil 701 erfolgen.Die Netzzuleitung ist über einen 2-poligen Hauptschalter mit mindestens 3 mm Kontaktöffnung zu führen und mit maximal 6A abzusichern! Bei der Planung und Er-richtung von Sanitäranlagen sind die entsprechenden örtlichen, nationalen und internationalen Normen und Vorschriften zu beachten!

Installationshinweise

Betriebsspannung: 230V / 50HzLeistungsaufnahme: ca. 2 VAMagnetventil: 24V / 50HzAktivbereich: 50 cm vorjustiert 30 - 70 cm einstellbarVorspülung: 1 sec. bedarfsabhängigHauptspülung: 1 - 10 sec.Fließdruck: 0,5 - 6 bar

Durchfluss: 0,3 - 0,7 l/sec. nach EN 12541 reduzierbarWasserzulauf: R 1/2“ IGWasserablauf: R 1/2“ AG

Abmessungen:Frontplatte: 160 x 185 mmWandeinbaukasten: 135 x 165 x 77 mm

Technische Daten

2

Einbaumaße in cm

~11

5

min. 100

~50

DN 15

65

Page 3: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Montage

Vorspülung durchführen

3

Vorabsperrung schließenSchmutzfilter einsetzen

Auf

Zu

Magnetventil mit Dichtungen einsetzenAchtung! Flussrichtung bei MV beachten

Vorabsperrung öffnenMontagerahmen anbringen

MV

230V

Netzzuleitung abschalten, Magnetventilanschließen, Netzanschluss herstellenBlockklemme in die vorgesehene Halterungstecken, Netzzuleitung wieder einschalten.

Page 4: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Montage

4

1

5

10

Spülmenge in l Fließdruck 2,0 3,0 4,0

1 bar 5,5 s 7,0 s 10,0 s2 bar 4,5 s 5,5 s 7,5 s3 bar 3,0 s 4,5 s 6,0 s4 bar 2,5 s 4,0 s 5,5 s5 bar 2,5 s 4,0 s 5,0 s

Spülzeit einstellen 1 - 10 sec.

Diagnose LED, leuchtet bei Reflex1

Elektronikplatte in Montagerahmeneinhängen und verschrauben.

Page 5: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Service und Störungsbehebung

59

Wasser fließt ständig

MV-Stecker abziehen

Wasser fließt weiter Elektronikplattetauschen

Spülung funktioniert noch immer nicht

MV falsch eingebaut (Flussrichtung beachten)Mindestwasserdruck 0,3 bar beachten

JA

NEIN

Wasser fließt nicht

Elektronik abnehmen, Wasserzulauf, Vorabsperrung und Schmutzfilter prüfen

LED leuchtet nicht LED leuchtet

Elektronik tauschen

Spülung tritt ein, LED blinkt während der Spülung

Verweilzeit von 4 sec. beachten

Reflex beenden und Spülung kontrollieren

Reichweite - Aktivbereichmit Reflektor (Papier, etc.)

auf ca. 50 bis 60 cm justierenggf. Elektronik tauschen

Dabei Hand oder anderenReflektor (Papier, etc.)

Elektronik mittels Diagnose LEDauf Funktion prüfen

Netzspannung prüfen

Spülung tritt nicht ein

Elektronik tauschen

Magnetventil tauschen

MV tauschen

Page 6: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Ersatzteile

6

503 846 Absperrventil

998 608 Magnetventil 24V

BurdaTronic U-01 ElektronikplatteEdelstahl, 230 V Netzanschluss

BurdaTronic U-02 ElektronikplatteEdelstahl, 9 V Batteriebetrieb

Page 7: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Funktion

7

Mindestverweilzeit 4 sec. Bedarfsabhängige Vorspülung 1 sec. wenn letzte Spülung länger als 5 min. zurückliegt

Einstellbare Hauptspülung von 1 bis 10 sec.

Hygienespülung bei 24 Stunden Nichtbenutzung

503 846 Absperrventil

998 608 Magnetventil 24V

BurdaTronic U-01 ElektronikplatteEdelstahl, 230 V Netzanschluss

BurdaTronic U-02 ElektronikplatteEdelstahl, 9 V Batteriebetrieb

Page 8: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Herbert Burda GmbHKrefelder Straße 8740549 Düsseldorf

Tel. 0211 950 01- 0Fax 0211 50 05 75

www.burda-online.com

Page 9: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Installation GuideNo-touch infrared single urinal control BurdaTronic U-01 / U-02

Page 10: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

No-touch infrared single urinal control. Pre-flushing as required, adjustable main flushing cycle, and hygiene flushing when not used for 24 hours. Suitable for moun-ting on Burda carcass set.

Consists of:Electronic board assembly with integrated power supply,mounting frame, and magnetic valve.Mounting and installation must be performed by

licensed craftsmen to DIN 1988 and VDE 0100 part 701 standards only.The mains supply lead is to be led via a 2-pole mains switch with at least a 3mm contact gap and to be protected with 6A maximum!When planning and installing sanitary systems, the relevant local, national, and international standards and regulations must be complied with!

Notes on Installation

Operating voltage: 230V / 50HzPower input: approx. 2 VAMagnetic valve: 24V / 50HzActive range: approx. 50cm preset 30-70 cm adjustablePre-flushing: 1 sec, as requiredMain flushing: 1 - 10 secsFlow pressure: 0,5 - 6 bar

Flow rate: 0.3 - 0.7 l/sec can be red. acc. to EN 12541Water inlet: R 1/2“ IGWater outlet: R 1/2“ AG

Dimensions:Front panel: 160 x 185 mmWall-recess-mounted box: 135 x 165 x 77 mm

Technical Specifications

2

Mounting dimensionsin cm

~11

5

min. 100

~50

DN 15

65

Page 11: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Installation

Carry out pre-flushing

3

Advance shut-off, closeInsert dirt filter

OPEN

CLOSE

Insert magnetic valve with gaskets Caution! Watch out for flow direction at MV

Advance shut-off, openAttach mounting frame

MV

230V

Connect magnetic valve Establish connection to mains Insert terminal block into the provided holder

Page 12: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Installation

4

1

5

10

Flush volume in liters Pressure 2,0 3,0 4,0

1 bar 5,5 s 7,0 s 10,0 s2 bar 4,5 s 5,5 s 7,5 s3 bar 3,0 s 4,5 s 6,0 s4 bar 2,5 s 4,0 s 5,5 s5 bar 2,5 s 4,0 s 5,0 s

Adjust flushing time 1 - 10 secs.Diagnosis LED will be lit if there is a reflex

1

Suspend electronic board on moun-ting frame, and fasten it with screw

Page 13: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Service and Troubleshooting

59

water is not running

remove electronics, check water inlet,inlet shut-off mechanism, and dirt filter

while doing this, hold your hand oranother reflector (paper, etc.) approx.20cm in front of the device

LED is not litcheck function of electronics

with diagnosis LED LED is lit

check mains voltage

replace electronics

observe waiting period (4 secs.)

end reflex andcheck flushing system

flushing takes placeLED flashes during flushing flushing does not take place

replace magnetic valve

replace electronics

water is running constantly

water continues to run

replace electronics

YES

NOreplace electronicboard assembly

replace MV

flushing still doesnot function

MV installed incorrectly (verify flow direction)observe that the minimum water pressure must be 0.3 bar

Page 14: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Spare Parts

6

503 846 shut-off valve

998 608 24V magnetic valve

BurdaTronic U-01 electronic board assemblystainless steel, 230 V power supply

BurdaTronic U-02 electronic board assemblystainless steel, 9 V battery operation

Page 15: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Function

7

Minimum waiting period 4 secs. Pre-flushing as required 1 sec. if last flushing took place more than 5 min. ago

adjustable 0main flushing cyclefrom 1 to 10 secs.

hygiene flushing when not usedfor 24 hours

503 846 shut-off valve

998 608 24V magnetic valve

BurdaTronic U-01 electronic board assemblystainless steel, 230 V power supply

BurdaTronic U-02 electronic board assemblystainless steel, 9 V battery operation

Page 16: Montageanleitung - Herbert Burda · PDF fileting on Burda carcass set. Consists of: Electronic board assembly with integrated power supply, mounting frame, ... 5/25/2012 10:58:17 AM

Herbert Burda GmbHKrefelder Straße 87D-40549 Düsseldorf

Tel. +49 211 950 01- 0Fax +49 211 50 05 75

www.burda-online.com