monitoring solutions for 19 racks (cabinets) in it lan htemp-rack19 600 330 temp-1wire i3m 600 005...

10
Monitoring solutions for 19" Racks (cabinets) in IT © HW group www.HW-group.com

Upload: truongtruc

Post on 16-May-2018

219 views

Category:

Documents


4 download

TRANSCRIPT

Monitoring solutions for 19" Racks (cabinets) in IT

© HW group

www.HW-group.com

Temperature 1

placed next to technology

ProtoCols

WEB / http

XML

SNMP

Email

Alarming / notifications

Email for administrator

SNMP / SNMP trap

for NMS monitoring system

Ethernet LAN

(R1) One Point: TH -> GSM, SNMP, Email

Poseidon 3262 Tset

600 257

INPUTS:

- 1 Temperature

OUTPUTS:

- Ethernet: Email, SNMP NMS

Poseidon 3262

3m

°C

°C %RH

Temperature 1 / Humidity 1

next to Air input

ProtoCols

WEB / http

XML

SNMP

Email

SMS

GSM modem

RS-232

Alarming / notifications

Email for administrator

SNMP / SNMP trap

for NMS monitoring system

SMS for Admin as independent

backup solution.

Poseidon 3265

Ethernet LAN

(R2) One Point: TH -> GSM, SNMP, Email

SMS

HTemp-Rack19

600 330

Poseidon 3265 GSM Tset

600 283

INPUTS:

- 2 Temperatures

- 1 Humidity

OUTPUTS:

- Ethernet: Email, SNMP NMS

- GSM: SMS

3m°C

Temperature 2

placed next to technology

Ethernet LAN

Det. CONTROL

Power

Power failure detector

Door 1

Entrance door detector

Door 2

Sides and backdoor detector

WEB / http

XML

SNMP

Email

Alarming / notifications

Email for administrator

SNMP / SNMP trap

for NMS monitoring system

°C

Temperature 1 / Humidity 1

Cold air ingress to cabinet

Temperature 2

Hot air exit from cabinet

Temperature 3

Monitored device (heat sink)

°C %RH

°C3m

Protocols

Poseidon 3266

(R3) One Rack: THD -> SNMP, Email

SNMP trap for the video

survaillance system (PTZ)

HTemp-Rack19

600 330

Temp-Rack19

600 3293m

4m

PowerEgg

600 237

4 Door Contacts

600 119

Poseidon 3266 Tset

600 253

INPUTS:

- 3 Temperatures

- 1 Humidity

- 4 Door contacts

- 1 Power detection

OUTPUTS:

- Ethernet: Email, SNMP NMS

Ethernet LAN

Det. CONTROL

Power

Power failure detector

Door 1

Entrance door detector

Door 2

Sides and backdoor detector

Alarming / notifications

Email for administrator

SNMP / SNMP trap

for NMS monitoring system

°C

Temperature 1 / Humidity 1

Cold air ingress to cabinet

Temperature 2

Hot air exit from cabinet

Temperature 3

Monitored device (heat sink)

°C %RH

°C3m

(R4) One Rack: THD -> SNMP, Email, SMS

HTemp-Rack19

600 330

Temp-Rack19

600 3293m

4m

PowerEgg

600 237

4 Door Contacts

600 119

Poseidon 1250 Tset

600 042

INPUTS:

- 3 Temperatures

- 1 Humidity

- 4 Door contacts

- 1 Power detection

OUTPUTS:

- Ethernet: Email, SNMP NMS

- GSM: SMS

Protocols

WEB / http

XML

SNMP

Email

SMS

Poseidon 1250

GSM modem

RS-232

SMS

SMS for Admin as independent

backup solution.

GSM Modemcom G10

600 312

Ethernet LAN

WEB / http

XML

SNMP

Email

Alarming / notifications

Email for administrator

SNMP / SNMP trap

for NMS monitoring system

HTemp-Rack19

600 330

Temp-1Wire 3m

600 005 (in SET)

Temp-Rack19

600 329

Protocols

(R5) Four Racks: TH -> SNMP, Email

Four free-standing racks

°C %RH

°C

RJ12

°C

°C

°C

RJ12

RJ12

Poseidon 3262

RJ12

Temp-Rack19

600 329

RJ12

Temperature 1

Monitored device (heat sink)

Temperature 2

Monitored device (heat sink)

Temperature 3

Monitored device (heat sink)

Temperature 5

Monitored device (heat sink)

Temperature 4 / Humidity 1

Cold air ingress to cabinet

Temp-Rack19

600 329

Poseidon 3262 Tset

600 257

INPUTS:

- 5 Temperatures

- 1 Humidity

Placed in 4 19" Racks

OUTPUTS:

- Ethernet: Email, SNMP NMS

Ethernet LAN

HTemp-Rack19

600 330

Temp-1Wire 3m

600 005 (in SET)

Temp-Rack19

600 329

(R6) Four Racks: TH -> SNMP, Email, SMS

Four free-standing racks

°C %RH

°C

RJ12

°C

°C

RJ12

RJ12

Temperature 1

Monitored device (heat sink)

Temperature 2

Monitored device (heat sink)

Temperature 4

Monitored device (heat sink)

Temperature 3 / Humidity 1

Cold air ingress to cabinet

Temp-Rack19

600 329

Poseidon 3265 GSM2 Tset

600 313

INPUTS:

- 4 Temperatures

- 1 Humidity

Placed in 4 19" Racks

OUTPUTS:

- Ethernet: Email, SNMP NMS

- GSM: SMS

GSM modemRS-232

SMS

Poseidon 3265

RJ12

3m

°C

3m

°C

12

34

Sp

ide

r

10m

°C10m

°C10m °C

10m

°CDet Control

Det Control

3m

%RH

12

34

Sp

ide

r

10m

°C10m °C

10m

°C

10m

°C

12

34

Sp

ide

r

10m

°C10m °C

10m

°C

10m

°C

Door 1monitoring of the cabinet with

the Poseidon unit

Temperature 2

General room temperature

Humidity 1

General room humidity

General power input

UPS power input

UPS output

UPS backup power output

Temperature 1monitoring of the cabinet with

the Poseidon unit

12

34

Sp

ide

r

10m

°C10m °C

10m

°C

12

34

Sp

ide

r

10m

°C10m °C

10m

°C

10m

°C1

23

4

Sp

ide

r

10m

°C10m °C

10m

°C

10m

°C

Ceiling to raised

floor connection

10m

°C

Ceiling panel

Raised floor

Temperature 3

Temperature 4

Temperature 5

Temperature 6

Temperature 7

Temperature 8

Temperature 9

Temperature 10

Temperature 11

Temperature 12

Temperature 13

Temperature 14

Temperature 27

Temperature 25

Temperature 24

Temperature 23

Temperature 22

Temperature 21

Temperature 20

Temperature 19

Temperature 18

Temperature 17

Temperature 16

Temperature 15

(R7) ServerRoom: TH -> SNMP, Email

INPUTS:

- 2 Temperatures in the rack

- 1 Humidity in the rack

- 3 Contacts in the rack

- 24 Temperatures in room

OUTPUTS:

- Ethernet: Email, SNMP NMS

(R8) Four Racks + Customized extension: THD -> SNMP, Email, (SMS)

Ethernet LAN

Full monitored Rack:

3 Temperature

1 Humidity

1 Door

Four free-standing racks

°C %RH

°C

°C RJ12

Spider

600 273

Poseidon 3265 GSM2 Tset

600 313 (optionaly)

INPUTS:

- 8 Temperatures

- 2 Humidity

- 5 Door contacts

Placed in 4 19" Racks + extension

OUTPUTS:

- Ethernet: Email, SNMP NMS

- GSM: SMS

GSM modem

RS-232

SMS

Poseidon 1250

Door 2

Sides and backdoor detector

12

34

Sp

ide

r

12

34

Sp

ide

r

3m

°C

3m

°C

3m

°C

3m

°C

°C %RH

RJ12

to sensors in next cabinet..

Full monitored Rack:

3 Temperature

1 Humidity

1+3 Doors

Monitored Rack:

1 Temperature

1 Doors

Monitored Rack:

1 Temperature

1 Doors

Ethernet LAN

Alarming / notifications

Email for administrator

SNMP / SNMP trap

for NMS monitoring system

Temp-1Wire 3m

600 005 (in SET)

Temp-Rack19

600 329

(R9) Six Racks low-cost monitoring: T -> SNMP, Email

Six free-standing racks

Poseidon 3262

RJ12

Temp-Rack19

600 329

Temperature 5

Monitored device (heat sink)

Temp-Rack19

600 329

Poseidon 3262 Tset

600 257

INPUTS:

- 5 Temperatures

- 1 Humidity

Placed in 4 19" Racks

OUTPUTS:

- Ethernet: Email, SNMP NMS

Temperature 1

Hot air exit from cabinet

Temperature 2

Hot air exit from cabinet

Temperature 3

Hot air exit from cabinet

Temperature 4

Hot air exit from cabinet

Temperature 6

Monitored device (heat sink)

°C

°C

°C

°C

°C

RJ12

3m

RJ12

3m

RJ12

3m

RJ12

3m

°C

3m

Temp-Rack19

600 329

Temp-Rack19

600 329