A
A-3
APPLICATION• Linear diffuser system with engineered performance that integratesinconspicuously as an architectural feature of the space
• Desirable large capacity, single slot appearance
• Versatile pattern & volume control for installation in low or high sidewallsand ceilings for both heating and cooling applications
• Adjustable for horizontal or vertically projected air discharge patterns
• Supply, return, or exhaust air through the same continuous run ofarchitectural linear eliminates ceiling clutter and reduces installationcosts
• Draftless air distribution excellent for VAV applications – blankets of airwill not “dump” even at lowest flow rates
• Drywall / hard surface and suspended ceiling applications
PRODUCT FEATURES• Heavy extruded aluminum construction
• 12’ lengths available to minimize joints
• 1”, 1-1/2”, 2”, 2-1/2”, 3” slot widths
• 1 thru 4 slots
• Field adjustable weir type pattern controllers for horizontal left or right,or vertical projection air discharge patterns
• Controllers are cut to nominal 24” – allows for alternating patternchanges within the run from left or right horizontal, to vertical projection
• Adjustable controllers consist of two expandable elements for volumecontrol as well blank-off for inactive sections
• Baked-on Arctic white frames Models FFS & FFX, Baked-on black framesfor Models FFCM & FFBF. Controllers are black. Center T’s on multipleslot units are arctic white
OPTIONS• Custom curving for wall or ceiling applications – convex or concave!
• Mitered corners and end caps
• Multiple slots
• Custom color matching, anodized finishes
Curved FFS - 2 Slot(co
ncave mo
untin
gsurfa
ce)
• Custom formed for ceiling, convex and concave sidewall applications.• Contact your local Anemostat representative for details.
CURVED FREE FLO & PRO JET
Curved FFS - 4 Slot (flat mounting surface)
PATTERN CONTROL FLEXIBILITY (2 SLOT SHOWN)
1 WAY LEFTHORIZONTAL
1 WAY RIGHTHORIZONTAL
2 WAY OPPOSITEHORIZONTAL
VERTICAL PROJECTION(and other angles)
A-4
Arc
hite
ctu
ral D
iffus
ers
A
model Free Flo™Architectural Linear Slot Diffusers
product description
H
C
S H
G
D (DUCT OPENING)E (CEILING OPENING)
• Installed after drywall/plaster
H
1-1/41-1/21-3/4
22
C
3-1/24-1/25-1/26-1/2
7
MODEL
FFS-100FFS-150FFS-200FFS-250FFS-300
S
11-1/2
22-1/2
3
E
2-3/83-3/84-3/85-3/86-3/8
D
2-5/163-5/164-5/165-5/166-5/16
G
2-1/162-9/162-5/8
3-3/323-7/32
PATTERNCONTROLLLERS
END CAP DETAIL
1 - SLOT
CEILING OPENING = FREE FLO LENGTH + 1/2"DUCT LENGTH I.D. = FREE FLO LENGTH + 1/4"
FREE FLO NOMINAL LENGTH (ORDER SIZE)
1-1/8
MODEL FFS (SUPPLY) - Exposed Frame, Surface Mount (Drywall / Lay-In T-Bar)MODEL FFSR (RETURN) - Pattern Controllers Excluded
• Installed prior to drywall, prior to plaster
1/16 FOR TAPE ANDFEATHERING FLUSH TO
FINISHED CEILING
CEILING FRAMING
(BY OTHERS)
D (DUCT OPENING)
E (CEILING OPENING)
HSH
C
G
HCMODEL S ED G
FFCM-200
FFCM-300FFCM-250
FFCM-150FFCM-100
22-1/2
3
1-1/21
1-21/321-13/321-5/32
7/85/8
5-5/164-5/163-1/4
2-9/32
6-5/16
4-5/8
6-5/85-5/8
3-5/82-5/8
4-5/16
6-5/165-5/16
3-5/162-5/16
2-11/16
3-1/43-5/32
2-5/82-3/16
PATTERNCONTROLLLERS
END CAP DETAIL
1 - SLOT
DUCT LENGTH I.D. = FREE FLO LENGTH + 1/4"FREE FLO NOMINAL LENGTH (ORDER SIZE)
5/8
MODEL FFCM (SUPPLY) - Concealed Frame, Flush Mount, Plaster Concealed (Drywall)MODEL FFCMR (RETURN) - Pattern Controllers Excluded
Available in 1 - 4 Slots
Available in 1 - 4 Slots
SERRATIONS IN PLASTERS FRAMES INCREASE BONDING STRENGTH OF PLASTER WITH AN ADDITIONAL 40% INCREASE IN SURFACE AREA
model Free Flo™Architectural Linear Slot Diffusers
product descriptionA
rchite
ctura
l Diffuse
rs
A
A-5
• Installed prior to drywall/plaster ceiling-wall intersection
HCS
GX
D (DUCT OPENING)CEILING
FRAMING(BY OTHERS)
5/8
PATTERNCONTROLLLERS
END CAP DETAIL
SMODEL
FFX-300-1
FFX-150-1
FFX-250-1FFX-200-1
FFX-100-1
22-1/2
3
1-1/21
C
76-1/25-1/24-1/23-1/2
D
5-3/84-3/83-3/8
6-3/8
2-3/8
G
3-5/323-9/32
2-11/162-5/82-1/8
H
22
1-3/41-1/21-1/4
X
3-29/323-25/323-5/163-1/42-3/4
DUCT LENGTH I.D. = FREE FLO LENGTH + 1/4"FREE FLO NOMINAL LENGTH (ORDER SIZE)
1/32
MODEL FFX (SUPPLY) - Concealed Frame, Offset Mount (Drywall Ceiling / Offset)MODEL FFXR (RETURN) - Pattern Controllers Excluded
• Installed after drywall, prior to plaster
H
C
S H
G
E (CEILING OPENING)D (DUCT OPENING)
1/16 FOR TAPE ANDFEATHERING FLUSH TO
FINISHED CEILINGHCMODEL S ED G
FFBF-300
FFBF-150
FFBF-250FFBF-200
FFBF-100
22 1/2
3
1 1/21
22
1-3/41-1/21-1/4
6-1/25-1/24-1/23-1/2
7
4-3/8
6-3/85-3/8
3-3/82-3/8
4-5/16
6-5/165-5/16
3-5/162-5/16
2-5/8
3-7/323-3/32
2-9/162-1/16
PATTERNCONTROLLLERS
END CAP DETAIL
1 - SLOT
CEILING OPENING = FREE FLO LENGTH + 1/2"DUCT LENGTH I.D. = FREE FLO LENGTH + 1/4"
FREE FLO NOMINAL LENGTH (ORDER SIZE)
1-5/32
MODEL FFBF (SUPPLY) - Beveled Frame, Surface Mount, Plaster Concealed (Drywall)MODEL FFBFR (RETURN) - Pattern Controllers Excluded
1 Slot Only
Available in 1 - 4 Slots
SERRATIONS IN PLASTERS FRAMES INCREASE BONDING STRENGTH OF PLASTER WITH AN ADDITIONAL 40% INCREASE IN SURFACE AREA