model 9220 vari-slab tm - neo metro · latest product information tech sheet: ts9220 page 3 of 10...
TRANSCRIPT
Latest product information www.neo-metro.com
Tech Sheet: TS9220 Page 1 of 10 Revised: 11/10/2020
N E O - M E T R O A Member of Morris Group International
15125 Proctor Avenue • City of Industry, CA 91746 USA800.591.9050 • 626.855.4854 • Fax 626.937.4725
• WALL MOUNTED CUSTOM LENGTH SOLID SURFACE DECK WITH YOUR CHOICE OF INTEGRAL BASIN(S)
• CAST ENTIRELY FROM AS PIECE OF OPAQUE, POLYMER RESIN MATERIAL
• ACCOMMODATES OPTIONAL RESIDENTIAL/LIGHT COMMERCIAL MOUNTING CARRIER. HEAVY- DUTY COMMERCIAL FLOOR MOUNTED CARRIER IS ALSO AVAILABLE.
• INTEGRATED OVERFLOW WASTE OUTLET
• MEETS ADA WHEN INSTALLED PROPERLY
• MATERIAL OF CONSTRUCTION PHYSICAL PROPRIETIES IN COMPLIANCE WITH: CSA B45.5/IAPMO Z124 ANSI/ICPA SS-1
• MATERIAL OF CONSTRUCTION IS FLAME SPREAD AND SMOKE DEVELOPED RATED “CLASS A” PER THE FOLLOWING STANDARDS: ASTM E84-10 UL 723 ANSI/NFPA No. 255 UBC No. 8-1 MATERIAL ALSO COMPLIES WITH CANADIAN REQUIREMENTS CAN/ULC-S102 FOR FLAME SPREAD AND SMOKE DEVELOPED.
Member of U.S. Green Building Council
®Product Specification . . . The Slab is a one®piece, solid surface Deck with integral Basin(s). The Slab
Deck is configurable with up to four integral Basins. Width of Deck must be specified. The unit is cast in opaque, polymer resin solid surface material.
The Deck can be configured for Mounting Carriers (-MC) which includes an arm/wall mounted Carrier appropriate for residential or light commercial applications. An optional commercial floor mounted Arm/Carrier (-MC-FLR) is available for heavier commercial application and requires a 2" x 6" wall construction. Both Carrier systems are concealed in the wall; therefore, installation must be coordinated before wall is finished.
An Overflow Waste Channel is also integrated in the cast Basin, draining into the Drain assembly.
Dyson Airblade™ Wash+Dry Faucets are optionally available, in both deck and wall mounted versions.
A Removable Grid Strainer with a Close Elbow is provided with an 1-1/4” O.D. (32) Tailpiece is provided to accommodate a P-Trap (optionally available.
® The Slab Deck is ADA compliant when installed properly. Compliance is subject to the interpretation and requirements of the local code authority. Please check your local Accessibility Requirements.
The Integral Basin(s), on Model 9220-1, Basin can be offset depending on the size of Deck. Distances between Basins can be specified on models 9220-2, 9220-3 and 9220-4.
Model 9220Vari-Slab
TM
9220-1 WITH OVAL BOWL
9220-2 WITH 3679 (RECTANGULAR) BOWL
9220-3 WITH OVAL BOWL
9220-4 WITH EDGE BASIN
Model 9220
Tech Sheet: TS9220 Page 2 of 10 Revised: 11/10/2020
N E O - M E T R O
15125 Proctor Avenue • City of Industry, CA 91746 USAA Member of Morris Group International
800.591.9050 • 626.855.4854 • Fax 626.937.4725
G MOUNTING - Required Selection INIT.
Ad
d(+
) B SOLID SURFACE COLOR - Required Selection INIT.
F FAUCET - Required Selection INIT.
E BASIN SELECTION - Required Selection INIT.
Ad
d(+
)A
dd
(+)DESCRIPTION MODEL/OPTION #
A Configuration - Required Selection INIT.
o 9220-0 Vari-Slab™ Deck With No Basin
o 9220-2 Vari-Slab™ Deck With Two Basins
o 9220-4 Vari-Slab™ Deck With Four Basins
o 9220-3 Vari-Slab™ Deck With Three Basins
o 9220-1 Vari-Slab™ Deck With Single Basin
C BACKSPLASH /SIDESPLASH - Req’d Selection INIT.
Ad
d(+
)
Ad
d(+
)
APPROVAL FOR MANUFACTURECOMPANY:______________________________________________________________________________________________________________________________________________
PROJECT NAME: __________________________________________________________________________________________________________________________________________
SIGNEE'S NAME WRITTEN CLEARLY: ____________________________________________________________________________________________________________________________
DATE: _________________________________________________________________________________________________________________________________________________
AUTHORIZED SIGNATURE: ___________________________________________________________________________________________________________________________________
o -H0 No Faucet Hole For Wall Mounted Faucet
o -H1 Single Hole ø1-3/8” (ø35mm) Centered Hole
o -H34 4” Centerset ø1-3/8” (ø35mm) Centerset Holes
o -H38 8” Centerset ø1-3/8” (ø35mm) Centerset Holes
4”
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
D SIDE APRONS - Required Selection INIT.
Ad
d(+
)
o -BKS 3” Backsplash (Shipped Loose)
o -BLSS 3” Backsplash & Left Side Splash (Left Hand Corner) (Shipped Loose)
o -BRSS 3” Backsplash & Right Side Splash (Right Hand Corner) (Shipped Loose)
o -BLRSS 3” Backsplash & Left/Right Side Splash (Alcove)
(Shipped Loose)
o None
o -AFL Apron, Front & Left Sideo -AFR Apron, Front & Right Sideo -AFLR Apron, Front, Left & Right Side (Standard)
o None
8”
o -BBOV Oval Basin (Compatible with DYSON Airblade™) 16-3/4" W x 13-1/4" L x 5-1/2” D Basin (425.5mm x 336.5mm x 140mm)
o -BBSQ Square Basin 14" L x 14" W x 4" D Basin (356mm x 356mm x 102mm)
o -BBED Edge Basin (Compatible with DYSON Airblade™) 16-3/4" W x 13-3/4" L x 4" D Basin (425.5mm x 349mm x 102mm)
o -3679 Rectangular Basin 17” W x 14” L x 4”D Basin (356mm x 432mm x 102mm)
o -BBRD Round Basin (Compatible with DYSON Airblade™) Ø14-1/4” x 5” D Basin (Ø 362mm x 127mm)
o -FM Front Mount
o -MCS Mounting Carrier Sleeve (See Accessories
Section For Optional Carrier Type Page 4)
®Corterra Solid Surface Color
Color: ___________________
q Basin(s) Same Color As Deck (Standard)
q Contrasting Basin BLANCO (White)
(Refer to link below for available colors)
https://www.neo-metro.com/luxury-solid-surface
Vari-SlabTM
Customer is required to submit faucet spec sheet to confirm compatibility with Neo-Metro’s faucet drilling.
Latest product information www.neo-metro.com
Tech Sheet: TS9220 Page 3 of 10 Revised: 11/10/2020
N E O - M E T R O A Member of Morris Group International
15125 Proctor Avenue • City of Industry, CA 91746 USA800.591.9050 • 626.855.4854 • Fax 626.937.4725
Model 9220
FAUCET CONFIG. - Required Selection INIT.P-TRAP COVER OPTIONS - Optional Selection INIT.
Ad
d(+
)
o -FMTE Front Mounted P-Trap Cover With Hinged P-Trap Enclosure (NOT Compatible with Optional -MCS)
Note: One per Station. (See Page 5 for details)
H
I ACCESSORIES: (Ships Separately) INIT.
Ad
d(+
)
o WD06 Dyson Airblade™ Wash+Dry Wall Mounted Faucet (For Use with BBOV, BBRD or BBED Basins Only)
o -SO-BAT Sensor operated Battery Powered Deck Mounted Faucet
o -SO 9VAC Sensor operated Deck Mounted Faucet
o WD04 Dyson Airblade™ Wash+Dry Deck Mounted Faucet (For Use with -BBOV, -BBRD or BBED Basins Only)
o One o Two o Three o Four
o -PT P-Trap Waste (Must Specify Type)
o o o Plastic P-Trap Brass P-Trap None
o MXTP (ASSE 1070 Tempering Valve) ST70CP12 NOTE: Recommend One (1) Mixing Valve PerStation Valve Specs: 4.5 GPM (17 LPM) @ 45 PSI (310 kPa)
Length: Carrier Sets: Sleeves:30" to 45" 1 245" to 75" 2 375" to 105" 2 4
105" to 135" 3 5135" to 148" 3 6
NOTE: RECOMMENDED MOUNTING CARRIER ANDSLEEVE QUANTITY IS DEPENDENT ON DECK LENGTH.
o -MC-FLR Commercial Floor Mounted Arm/Carrier Required for commercial application (requires 2" x 6" wall construction)
o -MC Standard Arm/Wall Mounted Carrier Suggested for residential/ light commercial applications
o -PTC Wall Mounted P-Trap Enclosure (Compatible with Optional -MCS And -FM Front Mounting)
Note: One per Station. (See Page 5 for details)
Vari-SlabTM
Model 9220
Latest product information www.neo-metro.com
Tech Sheet: TS9220 Page 4 of 10 Revised: 11/10/2020
N E O - M E T R O A Member of Morris Group International
15125 Proctor Avenue • City of Industry, CA 91746 USA800.591.9050 • 626.855.4854 • Fax 626.937.4725
XL
C2
C3
XR
C1
W
Y
DIMENSION LEGEND:
KEY DESCRIPTION
Y DEPTH OF DECK
W WIDTH OF DECK
XLCENTER OF FIRST BOWL
FROM LEFT SIDE OF DECK
CENTER OF FIRST BOWL TO SECOND BOWL
C1
CENTER OF SECOND BOWL TO THIRD BOWL
C2
CENTER OF THIRD BOWL TO FOURTH BOWL
C3
XRCENTER OF LAST BOWL
FROM RIGHT SIDE OF DECK
DIMENSIONAL GUIDE
-BBSQ SQUARE BASIN -3679 RECTANGULAR BASIN
-BBED EDGE BASIN -BBOV OVAL BASIN -BBRD ROUND BASIN
BASINS
Vari-SlabTM
Latest product information www.neo-metro.com
Tech Sheet: TS9220 Page 5 of 10 Revised: 11/10/2020
A Member of Morris Group International
15125 Proctor Avenue • City of Industry, CA 91746 USA800.591.9050 • 626.855.4854 • Fax 626.937.4725
N E O - M E T R O
Model 9220
DIMENSIONAL INFORMATION
2314"
(591)
2418"
(613)
1"(25)
8"(203)
1318"
(333)
812"
(216)
18"(457)
2158"
(549)
20"(508)
134"
(44)
718"
(181)
718"
(181)
812"
(216)
2358"
(600)
2158"
(549)
2358"
(600)
2"(51)
5"(127)
20"(508)
8"(203)
-FM FRONT MOUNT BRACKET DIMENSIONAL DATA
-FMTE FRONT MOUNT P-TRAP COVER w/ HINGED P-TRAP ENCLOSURE DIMENSIONAL DATA
-PTC WALL MOUNTED P-TRAP COVER DIMENSIONAL DATA
2"(51)
5"(127)
20"(508)
8"(203)
2"(51)1"
(25)
ADDITIONAL LEFT & RIGHT SUPPORT ARMS DIMENSIONAL DATA
Vari-SlabTM
Latest product information www.neo-metro.com
Tech Sheet: TS9220 Page 6 of 10 Revised: 11/10/2020
A Member of Morris Group International
N E O - M E T R O
15125 Proctor Avenue • City of Industry, CA 91746 USA800.591.9050 • 626.855.4854 • Fax 626.937.4725
Model 9220-0
All dimensions are subject to manufacturer's tolerance of plus or minus (13) nominal and 1/2”subject to change without notice. assumes no responsibility for use of void or superseded data. Neo-Metro, City of Industry, CA, Member of Morris Group International. Please visit www.acorneng.com for most current specifications.
Vari-Slab No BasinTM
1 -MC-FLR CONCEALED FLOOR MOUNTED CARRIER SHOWN, MUST SPECIFY
2"(51)TYP
MUSTSPECIFY
30" MIN - 148" MAX(762 - 3759)
WIDTH
MUSTSPECIFY
18" - 33" (457 - 838)MAX DEPTH
4" (102)HEIGHT
*34"(864)
1
1 1
NOTE: NUMBER OF CARRIER ARMS WILLBE DETERMINED BY THE FACTORYBASED ON THE WIDTH OF CUSTOM DECK
9220-0 SHOWN FLOOR MOUNTED CARRIERS
W
Y
NOTE: CUSTOMER MUST VERIFY SPECIFIEDDIMENSIONS INDICATED WITH (*) SHALLMEET LOCAL ACCESSIBILITY STANDARDS
234" (70)
MAX
*3134"
(806)
1
112" (38)
TYP
Latest product information www.neo-metro.com
Tech Sheet: TS9220 Page 7 of 10 Revised: 11/10/202015125 Proctor Avenue • City of Industry, CA 91746 USA
800.591.9050 • 626.855.4854 • Fax 626.937.4725
N E O - M E T R O A Member of Morris Group International
Model 9220-1
All dimensions are subject to manufacturer's tolerance of plus or minus (13) nominal and 1/2”subject to change without notice. assumes no responsibility for use of void or superseded data. Neo-Metro, City of Industry, CA, Member of Morris Group International. Please visit www.acorneng.com for most current specifications.
Vari-Slab One BasinTM
1 -MC-FLR CONCEALED FLOOR MOUNTEDCARRIER SHOWN, MUST SPECIFY
2 REMOVABLE GRID STRAINER WITH 1-1/4" O.D.PLAIN END TAILPIECE
3 INTEGRAL BASIN, -BBSQ SQUARE BASINSHOWN, MUST SPECIFY
1
3
2
1
1
MUSTSPECIFY
30" - 148" MAX(762 - 3759)
WIDTH
2"(51)TYP
MUSTSPECIFY
*15" (381)MIN
MUSTSPECIFY
22"-24" (559-610) MAXDEPTH WITH BASIN
4" (102)HEIGHT
*34"(864)
4
4 -PTC FRONT MOUNT P-TRAP COVER SHOWN,MUST SPECIFY
9220-1 SHOWN WITH SQUARE BASIN & P-TRAP ENCLOSURE
NOTE: NUMBER OF CARRIER ARMS WILL BEDETERMINED BY THE FACTORY BASED ONTHE WIDTH OF CUSTOM DECK
NOTE: CUSTOMER MUST VERIFY SPECIFIEDDIMENSIONS INDICATED WITH (*) SHALL MEETLOCAL ACCESSIBILITY STANDARDS
XL
W
Y
2418"
(613)
4
2
1"(25)
8"(203)
15"(380)
2314"
(591)
234" (70)
MAX
*3134"
(806)
112" (38)
TYP
Latest product information www.neo-metro.com
Tech Sheet: TS9220 Page 8 of 10 Revised: 11/10/2020 800.591.9050 • 626.855.4854 • Fax 626.937.4725
A Member of Morris Group International
N E O - M E T R O
15125 Proctor Avenue • City of Industry, CA 91746 USA
Model 9220-2
All dimensions are subject to manufacturer's tolerance of plus or minus (13) nominal and 1/2”subject to change without notice. assumes no responsibility for use of void or superseded data. Neo-Metro, City of Industry, CA, Member of Morris Group International. Please visit www.acorneng.com for most current specifications.
Vari-Slab Two Basins TM
1 -MC-FLR CONCEALED FLOOR MOUNTED CARRIER SHOWN, MUST SPECIFY
2 REMOVABLE GRID STRAINER WITH 1-1/4" O.D. PLAIN END TAILPIECE
3 INTEGRAL BASINS, -BBOV OVAL BASINSHOWN, MUST SPECIFY
2"(51)TYP MUST
SPECIFY
*15" (381)MIN
MUSTSPECIFY
*26" (660)MIN
MUSTSPECIFY
56" MIN - 148" MAX(1422 - 3759)
WIDTHMUST
SPECIFY
22" - 24" (559 - 610)MAX DEPTH W/ BASIN
4" (102)HEIGHT
*34"(864)
1
1
42
4
1 1
4 -PTC FRONT MOUNT P-TRAP COVER SHOWN, MUST SPECIFY
NOTE: NUMBER OF CARRIER ARMS WILLBE DETERMINED BY THE FACTORYBASED ON THE WIDTH OF CUSTOM DECK
NOTE: CUSTOMER MUST VERIFY SPECIFIEDDIMENSIONS INDICATED WITH (*) SHALLMEET LOCAL ACCESSIBILITY STANDARDS
9220-2 SHOWN WITH OVAL BASIN & P-TRAP ENCLOSURE
MUSTSPECIFY
*15" (381)MIN
XL C XR
W
Y
2418"
(613)
1"(25)
8"(203)
2314"
(591)
15"(380)
234" (70)
MAX
*3134"
(806)
32112" (38)
TYP
Latest product information www.neo-metro.com
Tech Sheet: TS9220 Page 9 of 10 Revised: 11/10/2020
N E O - M E T R O
800.591.9050 • 626.855.4854 • Fax 626.937.4725
A Member of Morris Group International
15125 Proctor Avenue • City of Industry, CA 91746 USA
Model 9220-3
All dimensions are subject to manufacturer's tolerance of plus or minus (13) nominal and 1/2”subject to change without notice. assumes no responsibility for use of void or superseded data. Neo-Metro, City of Industry, CA, Member of Morris Group International. Please visit www.acorneng.com for most current specifications.
1 SUPPORT FRAME ASSEMBLY. (1) ASSEMBLY PERBASIN SHOWN, MUST SPECIFY
3 REMOVABLE GRID STRAINER WITH 1-1/4" O.D.PLAIN END TAILPIECE
4 INTEGRAL BASINS, -BBRD ROUND BASINSHOWN, MUST SPECIFY
MUSTSPECIFY
82" MIN - 148" MAX(2083 - 3752)
WIDTH MUSTSPECIFY
22" - 24" (559 - 610)MAX DEPTHWITH BASIN
*34"(864)
4" (102)HEIGHT
MUSTSPECIFY
*26" (660)MIN
MUSTSPECIFY
*26" (660)MIN
1
4
2
1
1 1
NOTE: NUMBER OF ADDITIONAL SUPPORTARMS WILL BE DETERMINED BY THEFACTORY BASED ON THE WIDTH OFCUSTOM DECK
NOTE: CUSTOMER MUST VERIFYSPECIFIED DIMENSIONS INDICATEDWITH (*) SHALL MEET LOCALACCESSIBILITY STANDARDS
9220-3 SHOWN WITH FRONT MOUNT BRACKETS & ROUND BASIN
MUSTSPECIFY
*15" (381)MIN
MUSTSPECIFY
*15" (381)MIN
2 LEFT AND RIGHT SUPPORT ARMS SHOWN FOR REFERENCE
5 INSTALLER PROVIDED WALL ANCHORS ANDANCHORING HARDWARE
3"(76)
5"(127)
2158"
(549)
3 3 3
2
11
XL C1 C2 XR
W
Y
Vari-Slab Three BasinsTM
Latest product information www.neo-metro.com
Tech Sheet: TS9220 Page 10 of 10 Revised: 11/10/2020
A Member of Morris Group International
N E O - M E T R O
15125 Proctor Avenue • City of Industry, CA 91746 USA800.591.9050 • 626.855.4854 • Fax 626.937.4725
Model 9220-4
All dimensions are subject to manufacturer's tolerance of plus or minus (13) nominal and 1/2”subject to change without notice. assumes no responsibility for use of void or superseded data. Neo-Metro, City of Industry, CA, Member of Morris Group International. Please visit www.acorneng.com for most current specifications.
1 INSTALLER PROVIDED WALL ANCHORS ANDANCHORING HARDWARE
2 REMOVABLE GRID STRAINER WITH 1-1/4" O.D.PLAIN END TAILPIECE
3 INTEGRAL BASINS, -BBED EDGE BASIN SHOWN, MUST SPECIFY
MUSTSPECIFY
108" MIN - 148" MAX(1048 - 3759)
WIDTH
MUSTSPECIFY
22"-24" (559-610)MAX DEPTHWITH BASIN
*34"(864)
4"(102)
MUSTSPECIFY
*26" (660)MIN
MUSTSPECIFY
*26" (660)
MIN
2 2 4
1
3
2
2
MUSTSPECIFY
*26" (660)
MIN
4 OTIONAL -FMTE HINGED FRONT MOUNT P-TRAP ENCLOSURE SHOWN, MUST SPECIFY
4
4
9220-4 SHOWN WITH FRONT MOUNT HINGED P-TRAP ENCLOSURE & EDGE BASIN
MUSTSPECIFY
*15" (381)MIN
NOTE: CUSTOMER MUST VERIFYSPECIFIED DIMENSIONS INDICATEDWITH (*) SHALL MEET LOCALACCESSIBILITY STANDARDS
NOTE: ADDITIONAL SUPPORT ARMS MAY BEREQUIRED AND WILL BE DETERMINED BY THEFACTORY BASED ON THE WIDTH OF CUSTOMDECK
MUSTSPECIFY
*15" (381)MIN
5 LEFT AND RIGHT SUPPORT ARMS SHOWN FOR REFERENCE
5
3"(76)
718"
(181)
718"
(181)
2158"
(549)
XL C1 C2 C3 XR
W
Y
15"(381)
Vari-Slab Four BasinsTM