modbus i/o - acromag
TRANSCRIPT
Tel: 248-295-0880 e-mail: [email protected] www.acromag.com
M o d b u s I / OM
odbus I/OBusW
orks ®
SoftwareInterface PackageThis package includes Windows® ConfigurationSoftware, an RS-232-to-485 Serial PortConverter, and an RS-485 Signal Cable. Thesecomponents provide everything you need to setup a Series 900 I/O module from your desktopPC before installing it on the network.
n Ordering Information900C-SIPSoftware Interface Package. Includes Configuration Software (5034-186), Non-isolated RS-232 to RS-485 Serial Port Converter (5034-214), and RS-485 Cable (5034-202).Items can also be ordered separately below.5034-186Configuration Software for Windows XP and newer on CD-ROM.5034-214Non-isolated RS-232 to RS-485 Serial Port Converter, DB-9F to DB-9F.5034-202RS-485 to 3-wire Cable Converter, DB-9M to 3 x 12AWG RS-485 Cable, 8 ft.
Software Interface Package Model No. 900C-SIP
RS-232 to RS-485 Converter
(non-isolated)
Configuration Software for Windows
RS-485 Cable (DB-9)
Configuration Kit
Universal 50WPower SupplyThe PS5R-VB24 is the ideal power source to drive your network.
Input Power RequirementUniversal power85 to 264V AC,105 to 370V DC
Output24V DC, 0.65A (15W)
n Ordering InformationPS5R-VB24Universal Power Supply
DIN-RailMountingFor your convenience, Acromag offers severalmounting accessories to simplify your systeminstallation. Our 19” rack-mount kit provides aclean solution for mounting your I/O modulesand a power supply. Or you can buy precut DINrail strips for mounting on any flat surface.
n Ordering Information20RM-16-DIN19" rack-mount kit with DIN rail.DIN RAIL 3.0DIN RAIL 16.7DIN rail strip, Type T, 3 inches (75mm) or16.7 inches (425mm)
V.ADJ
DC ON
M3.5 Terminal Screws
10-ø6.5
4-ø4.5
80
13 13 13 13
90
12
7.35
75605
Top View(dimensions in mm)
35.3
695
3.8
Side View(dimensions in mm)
Dimensions in inches (mm).
RS-232/485�Converter�
(non-isolated)
5034-214
RS-485�to 3-wire
5034-202
Network Power
Mounting Hardware
8400100.qxp 3/20/2006 3:18 PM Page 69
8401-003
(This page intentionally left blank.)
Tel: 248-295-0880 ■ [email protected] ■ www.acromag.com ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
PERSONAL COMPUTERRUNNING WINDOWS
98/ME/2000/XP
6 FEET OF CABLE
USB MALE
DB9P
RS232
4001095USB SERIAL CONVERTER
LED
TO HOST USB PORTHOSTUSB
CONFIGURATIONSOFTWARE
ACROMAGHOST PC RUNNING
DescriptionThis device is a USB-to-serial adapter that you can use to communicate with many Acromag I/O products for setup and re-configuration for your application.
Key Features & Benefits■ Connects to I/O modules via USB
(other adapters may be necessary)
■ Complete RS232 control signals
■ Conforms to USB Specification, Version 1.1
■ USB-powered
■ Cable length, 6 ft., UL approved
Performance SpecificationsUSB SpecificationVersion 1.1Data rateUp to 115.2KbpsEnvironmental StandardsRoHS-compliantBasic Power Consumption150mAPC RequirementsWindows® 7 and newer.
Ordering InformationNOTE: For more information visit www.acromag.com.
Adapters4001-095USB to serial adapter. Includes driver CD and manual.5030-913Serial port adapter. DB9S connector to RJ11 jack.5034-202RS-485 to 3-wire cable converter and cable, DB-9M to 3 x 12AWG RS-485 cable, 8 ft. 5032-787RS-232 to 151T transmitter configuration device converter and cable, 6 ft. 5034-214Non-isolated RS-232 to RS-485 Serial Port Converter, DB-9F to DB-9F.
Cables5030-902Cable. 6 feet long with RJ11 plug at each end.
Simplifies configuration of Acromag I/O Modules ◆ Enables configuration via USB port
Model 4001-095 USB-to-Serial Adapter
Accessories
9-PIN CONNECTOR (DB9S)
RJ11 PLUG(6 CONDUCTOR)
(6 CONDUCTOR)RJ11 JACK
INTELLIPACK
MODEL 5030-913
SERIAL ADAPTER
MODEL 5030-902(6 feet long)
BC
D D
RS
-232
COM
A
RS
-485
5034-202
CABLE 5034-202
RS232 TO RS485 SERIALCONVERTER(MODEL 5034-214)
DB9 MALEDB9 FEMALE DB9 FEMALE
IntelliPack 800x Series Adapter and Cable
900MB Modbus Series Adapter and Cable
8400-572b
(This page intentionally left blank.)
Tel 248-295-0880 ■ [email protected] ■ www.acromag.com ■ 30765 Wixom Rd, Wixom, MI 48393 USA
Network Accessories: 4683 Series
DescriptionModels4683-TTM-1F: 115V AC Power 4683-TTM-2F: 230V AC Power 4683-TTM-3F: 24V AC Power
Acromag’s RS-485 network repeater device allows users to take full advantage of the RS-485 standard’s extended communication distances and multi-dropping capabilities. In addition, these devices offer field selectable End-of-Line Network (EOLN) terminations on both the A and B networks.
Operation is transparent to all devices and no handshaking is required. Up to thirty-two RS-485 devices can be driven. Network repeaters are ready to mount on any base plate. Or, for a harsh environment, it can be installed in a NEMA enclosure of your choice. No enclosure is necessary for use in a laboratory or office. Installation requires mounting, connecting power and cables, and setting the baud rate.
ApprovalsUL/cUL listed: Energy management equipment
Key Features & Benefits■ Designed for use with Johnson Controls
N2 or BACnet bus
■ No handshaking
■ No extra control lines
■ I/O signal isolation
■ Baud rates of 600, 1200, 2400, 4800, 9600,19.2K, 38.4K, and 76.8K are switch selectable
■ Field-selectable end-of-line networkterminations on both A and B sides
■ Electrical transient protection is provided. Thisprotects the host computer from destructivenoise spikes and othertransient signals.
■ Status LED’s indicate transmissiondirection, RS-485 bus fault conditions, andpower applied.
■ 24/115/230V AC power available
■ No separate transformer required with 24V ACunits (4683-TTM-3F)
OperationModel 4683-TTM-xF network repeaters isolate and boost RS-485 signals allowing communication signals to travel another 4000 ft. Each repeater permits the addition of another 32 unit load to a network.
The repeater has two RS-485 “sides” known as the A and B sides. The A side typically connects to the network towards the host and the B side connects to the extended network. Functionally, the A and B sides are equivalent.
Repeaters receive AC power through a 3-screw terminal strip. Transient signal protection is provided on both RS-485 sides.
When both RS-485 lines are idle, each side is in receive mode. When a ‘1’ to ‘0’ transition is detected (signifying a start bit) on either side, the opposite side’s transmitter is enabled. The transmitter stays enabled for one character’s time (based on the baud rate switch setting). The received character is then passed through.
For N2 or BACnet MS/TP bus ◆ Drives up to 32 RS-485 devices ◆ Isolates and boosts signal up to 4000 ft.
4683-TTM RS-485 to RS-485 Network Repeater
D DD COMDCOM
RS-485SIDE B
BAUDRATE
GW
L2 G
FAULTA
FAULTB
AC (HI)
StatusLEDs
PWR
GROUND
L1
L1 RS-485SIDE A
AC (LO)NETWORK CONNECTIONS
4683-TTM-1F (115VAC)
4683-TTM-2F (230VAC)
4683-TTM-3F (24VAC) GCOMHOT
1 - 6002 - 12003 - 24004 - 4800
5 - 96006 - 19.2K7 - 38.4K8 - 76.8K
RS
-485
SID
E B
24V
DC
RT
N
CO
M
DD DRT
RT _
24V
DC
RS
-485
SID
E A C
OM
DRT
RT _ NC
S1
1 2 3 4 5 6 7 8
TXA - B
TXB - A
StatusLEDs
Baud RateSwitches
ACInput TB1TB2
TB3
ON
8400-404d
Tel 248-295-0880 ■ [email protected] ■ www.acromag.com ■ 30765 Wixom Rd, Wixom, MI 48393 USA
4683-TTM RS-485 to RS-485 Network Repeater
Network Accessories: 4683 Series
Acromag, Inc. Phone: (248) 295-0880 � Fax: (248) 624-9234 - 4 - � E-mail: [email protected] � On-Line: http://www.acromag.com
The station configuration drawing is for general illustration purposes only. Johnson Controls system customers should instead refer to the Metasys® Network Technical Manual for N2 Bus Communication, or the MS/TP Communication Bus Technical Bulletin for wiring connections using the 4683-TTM-xF repeater.
R
R
R
R
T D
32 65 8
D
R R R R
3
2
5
2
3
4
5
7
8
10
11
12
13
6
7
8
9
14
15
17
18
20
22
23
25
R
R R
COM
TXB - A
R
COM 24VDC 24VDC
1
4
1
6
9
16
19
21
24
23
T D
1 4 7
T T D
W L2
POWER FAULT A BAUD
RATE
RS-485SIDE A
A-N3
S1
NCR RS-485SIDE B
TXA - B FAULT
B
RTN
OR
C
A
COM
TX
RX
TX
RX
5 COM
TXRX
7
3
DSR
RX
RTS
G
L1
G
L1
G
A-N2
B2
CD
CTS
TX
AC (LO)
-1 OPTION115VAC
RED POWER LED
AC (LO) COM AC (LO)
-3 OPTION24VAC
3 - 24004 - 4800
7 - 38.4K8 - 76.8K
S1 - BAUD RATE1 - 600 5 - 9600
1 - 600 5 - 96002 - 1200 6 - 19.2K3 - 2400 7 - 38.4K 4 - 4800 8 - 76.8K
B-N1NC A-N32
A-N31
RS232C
BA
HOSTDE9
COM
DB25
Ground
AC (HI)
acromag
Ground
AC (HI)
Ground
HOT AC (HI)
ANYRS485DEVICES
S1 - SET BAUD RATETO MATCH BAUDRATE OF NETWORK.
2 - 1200 6 - 19.2K
RS485 REPEATERMODEL 4683-TTM-X
RS485
A-N30
B-N2 B-N3
RS485
B-N4 B-N5
UP TO 32NODES PERNETWORKSEGMENT
B-N32
COM
SIGNALS ATCONVERTER
HOST
RED RS485 FAULT LED (SIDE A) TRANSMIT DIRECTIONB-TO-A & A-TO-B
-2 OPTION230VAC
DE9
DB25
TO HOST
CONNECTIONSTO HOST COMPUTER
HOST PC
RED RS485 FAULT LED (SIDE B)
NOTE: SIDE-A AND SIDE-B EOLTERMINATION JUMPERS ENABLED
UP TO 32NODES PERNETWORKSEGMENT
120 OHM TERMINATIONRESISTOR REQUIREDAT END OF NETWORKOR LAST DEVICE ONLY
IMPORTANT:MODEL 4683-TTM-X UNITSINCLUDE INTERNAL, FIELDSELECTABLE END-OF-LINE(EOL) TERMINATIONRESISTORS FOR THE A ANDB SIDES. THESE AREENABLED VIA INTERNAL JUMPERS. DO NOT USEEXTERNAL TERMINATIONWITH INTERNAL EOLJUMPERS ENABLED.
SEE UNIT LABELTO VERIFY POWERREQUIREMENTS
NOTE: JUMPERED PINS ARENULL-MODEM CONNECTIONSWHICH ALLOW COMMUNICATIONBETWEEN THE HOST ANDACROMAG SERIES 4100/4200I/O STATIONS.
EXTENDED NETWORK
ANY RS-485 DEVICE
MODEL 4683-TTM-XF REPEATER SYSTEM CONNECTIONS
RS485Converter
8400-404d
Tel 248-295-0880 ■ [email protected] ■ www.acromag.com ■ 30765 Wixom Rd, Wixom, MI 48393 USA
4683-TTM RS-485 to RS-485 Network Repeater
Network Accessories: 4683 Series
3 2 1
J4
2
J1
2 2
J2
23
D
S1
D D
3 2 1
3
1
3
1
3
1
J4
1
8 67
J2J1
5 34 2 1
J3
J2
J4J3
2
J1
COM D COM
32
F1
Vcc
D
D
EOLDISABLED
EOLDISABLED
3
1
RS-485SIDE B
J3
TXA - B
FAULT B
1
TXB - A
BAUDRATE
G W
L2G
FAULT A
AC (HI)
FUSE 3AG0.5A, 250V
StatusLEDs
StatusLEDs
1200 OHMS
PWR
220 OHMS
1200 OHMS
JUMPER PAIR(ONE SIDE)
EOL ENABLED
EOL JumpersSide B (OUT)
EOL ENABLED
EOL JumpersSide A (IN)
GROUND
L1
L1RS-485SIDE A
EOL JUMPERSEQUIVALENT CIRCUIT(4683 UNITS ONLY)
AC (LO)
NETWORK CONNECTIONS
REMOVE THIS SCREW ON EACHSIDE TO REMOVE COVER
Baud RateSwitches
G COM HOT
1 - 6002 - 12003 - 24004 - 4800
5 - 96006 - 19.2K7 - 38.4K8 - 76.8K
MODEL 4683-TTM-1F REPEATERMODEL 4683-TTM-2F REPEATERMODEL 4683-TTM-3F REPEATEREnd-of-Line (EOL) Termination Jumper Locations.Input Power Fuse Location.
RS
-485S
IDE
B
24V D
C
RT
N
CO
M
D DD RT
RT
_
24V D
C
RS
-485S
IDE
ACO
M
D RT
RT
_NC
4683-TTM-1F (115VAC)
4683-TTM-2F (230VAC)
4683-TTM-3F (24VAC)
NOTE:-3F 24V AC units do not require aseparate transformer. 24V AC powerfrom the RS-485 devices may be used.
T
21
S1
543 876
T TD D NC R R D
COM
RTN
24VD
C
4.30
2.10
TYP
0.30
3.70
BAUDRATE
T
(53.34)
(7.62)
(93.98) acromag
FAULT A
6.40
7.0
R R
RS-4
85SI
DE A
TXB - A
COM
RS-4
85SI
DE B
FAULT B
TXA - B
D
24VD
C
(177.80)
TYP
0.30
POWER
(109.22)
(162.56) (7.62)
1 - 6002 - 12003 - 24004 - 4800
5 - 96006 - 19.2K7 - 38.4K8 - 76.8K
Switch Variation Switch Operation
Slide Switch Slide with arrow to turn ON.
Slide opposite to arrow to turn Off.
Toggle Switch Depress toward numbers to turn On (Closed).
Depress toward OPEN to turn Off.
8400-404d
Tel 248-295-0880 ■ [email protected] ■ www.acromag.com ■ 30765 Wixom Rd, Wixom, MI 48393 USA
Network Accessories: 4683 Series4683-TTM RS-485 to RS-485 Network Repeater
Performance Specifications
■ Communication SpecificationsBaud RatesSwitch settings on unit for 600, 1200, 2400, 4800, 9600, 19.2K, 38.4K, and 76.8K baud rates. Switch must be in the proper baud rate position for proper operation.RS-485 Bus LoadingOne unit load equivalent.RS-485 Bus DriveComplete RS-485 compliance for up to 32 unit loads (31 unit loads if a repeater is used).End-of-Line Termination NetworkThe EOLN termination network is shown on the right and is individually selected on both the A and B sides by a pair of shorting clips. The A-side is controlled by jumper pair J1, J2 and the B-side is controlled by jumper pair J3 and J4.The EOLN termination network is enabled for the A side or B side when the associated pair of jumpers are positioned over pins 1 and 2. Conversely, the EOLN is disabled (out of the circuit) when the pair jumpers are positioned over pins 2 and 3.DuplexHalf duplex only.Data FormatTen bits typical (1 start bit, 8 data bits, and 1 stop bit). Other formats are supported.
■ SpecificationsPower Line Fuse0.5A, 125V, 0.75A, 3AG type.IsolationProvides galvanic and opto-coupler isolation between RS-485(A), RS-485(B), AC power, and chassis ground. Common mode voltages are permitted up to 250V rms or 354V DC (withstands a 1500V AC dielectric strength test for 1 min. without breakdown) on a continuous basis. Complies with requirements outlined in ANSI C39.5-1974 for voltage ratings specificed.RFI ResistanceWithstands an RFI field strength of 10V per meter at 27 Mhz, 151 Mhz, and 467 Mhz with no digital effect, per SAMA PMC 33.1.Line Noise EffectsField and power line terminals withstand ANSI/IEEE C37.90-1978 Surge Withstanding Capability (SWC) Test with no component failures. Unit is tested to a standardized test waveform that is representative of surges (high-frequency transient electrical interference), observed in actual installations.Communications ConnectionsNetwork repeater - both RS-485 connectors use modular terminal blocks with screw clamps. Wire range 14 to 26 AWG.Power Wire ConnectionsNetwork repeater terminal block. See label on unit for power to be applied to unit.Shipping Weight3.0 pounds (1.4 kg) packed per unit.
■ EnvironmentalOperating temperature-25 to 70° C (-13 to 158° F)Storage temperature-25 to +85° C (-13 to 185° F)Relative humidity0 to 95% RH (noncondensing), up to 40° C (104° F).Power4683-TTM-1F 115VAC ±10%, 50/60 Hz, 0.05A4683-TTM-2F 230VAC ±10%, 50/60 Hz, 0.03A4683-TTM-3F 24VAC ±10%, 50/60 Hz, 0.18A typicalApprovalsUL/cUL listed – energy management equipment.
Ordering Information
Models4683-TTM-1F115V ACPower.4683-TTM-2F230V ACPower.4683-TTM-3F24V ACPower.
AccessoriesSee www.acromag.com for more information.
3 2 1D
3 2 1D
1200Ohms
1200Ohms
220Ohms
8400-404d
Tel: 877-214-6267 ■ [email protected] ■ www.acromag.com ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
DescriptionAcromag’s configuration software is the key to the I/O modules’ easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
This package includes the Configuration Software, an RS232-to-485 Serial Port Converter, RS485 Signal Cable, and an USB to Serial adapter. These components provide everything you need to set up a Series 900 I/O module from your desktop PC before installing it on the network.
Software Compatibility
Windows® XP or newer.
Ordering InformationNOTE: For more information, visit www.acromag.com.
Models900C-SIPConfiguration Software Interface Package. Includes user manual, CD, non-isolated RS232-to-RS485 serial port converter (5034-214), RS485 cable (5034-202), and USB adapter (4001-095).4001-095USB-to-DB9 serial port (RS232) adapter. (Doesn’t support Windows® XP)5034-186Configuration software on CD-ROM.5034-202RS485 to 3-wire cable converter and cable, DB-9M to 3 x 12AWG RS485 cable, 8 ft.5034-214Non-isolated RS232-to-RS485 serial port converter, RS232 port-powered, DB-9F to DB-9F.
Connection DiagramSee following page.
Configuration Software ◆ USB-to-RS232 Adapter ◆ RS232-to-RS485 Adapter ◆ Interface Cable
Model 900C-SIP Configuration Software Interface Package
Series 900MB Modbus RTU I/O
For Windows®
877.214.6267
8400-568c
Tel: 248-295-0880 ■ [email protected] ■ www.acromag.com ■ 30765 S Wixom Rd, Wixom, MI 48393 USA
Series 900MB Modbus RTU I/O
RS
-232
RS
-485
900C-SIP COMMUNICATION CONNECTIONS
6 FEET OF CABLE
USB MALE
DB9 MALE
RS232
USB SERIAL CONVERTER 4001-095
LED
TO HOST USB PORT
OR
HOSTUSB
TO HOST RS232 SERIAL PORT
HOSTRS232
DB9MALE
HOST RS232 SERIALPORT CONNECTOR ORUSB CONNECTOR ATBACK OF PC
CONNECT THE RS232SIDE OF CONVERTERTO THE PC
CONNECT THE RS485SIDE OF CONVERTERTO THE CABLE
RS232 TO RS485 SERIALCONVERTER(MODEL 5034-214)
DB9 FEMALE DB9 FEMALE
PC RUNNINGACROMAGMODBUS CONFIGSOFTWARE
INSTALL MODBUS CONFIGURATION SOFTWARE
WINDOWS-BASED PERSONAL COMPUTER
THE RS232-to-RS45 PORT-POWERED CONVERTER 5034-214IS INTENDED FOR CONFIGURATION PURPOSES FOR ONEDEVICE. IT IS NOT SUITABLE FOR DRIVING A FULLY LOADEDRS485 NETWORK. THE USE OF AN EXTERNALLY POWEREDRS485 CONVERTER IS RECOMMENDED FOR DRIVING MULTIPLEDEVICES OF AN RS485 NETWORK.
2
0
R
ST
TB1
12
45 44
15
42 41
TB2
23
34
BC
26
31
DFT
D
D D
A
B
A
TB4
TB3
3
1
RUN
11 13 14
46 43
2221
36 35
25
32
TB1
Acromag
RS
-232
TB1
RS485
TB4
COM
A
TB2
PWR
B
TB3
RS
-485
RED
COM
D
D
RS-485TB4
CO
M
CO
M
16 24
33
5034-202
STATUS LED (YELLOW)RUN/PWR LED (GREEN)
D C
WIRE
CABLE 5034-202
ANY 900MB MODULE
GREEN
BLACK
CONNECT WIRES AS SHOWN
COLOR
ANY 900MB MODULE
CONNECT THE RS232SIDE OF CONVERTERTO THE PC
CONNECT THE RS485SIDE OF CONVERTERTO THE CABLE
RS232 TO RS485 SERIALCONVERTER(MODEL 5034-214)
CAUTION: DO NOT CONNECT THECABLE DIRECTLY TO THE PC WITHOUTTHE CONVERTER, OR DAMAGE TOTHE MODULE MAY RESULT.
DEFAULT MODE SWITCH -PUSH FOR DEFAULT MODE
STATUS LED FLASHES INDEFAULT MODE
REFER TO THE USER'S MANUALTHAT CAME WITH YOUR MODULETO COMPLETE THE MODULE'SPOWER AND I/O CONNECTIONS
DB9 MALEDB9 FEMALE DB9 FEMALE
8400-568c
All trademarks are property of their respective owners. Copyright © Acromag, Inc. 2019. Data subject to change without notice. Printed in USA 5/2019.