Page 1: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Pos: 2 /CNDEX/00 Title/00_Title -- H8137xPx-S_H8137xK-S @ 63\mod_1500620160705_0.docx @ 801123 @ @ 1

2TMD041700D0042 │ 01.08.2017

Operating InstructionsABB-Welcome IP

Video outdoor stationH8137xPx-SH8137xK-S

=== Ende der Liste für Textmarke Titel ===

Page 2: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Table of contents

Operating Instructions VER:1.0 │2

Pos: 4 /DinA-4 -- Online -- standard content/TOC/TOC -- international - 4 heading levels @ 57\mod_1488436026244_15.docx @ 754287 @ @ 1

Table of contents

1 Notes on the instruction manual .................................................................................................................. 3

2 Safety .......................................................................................................................................................... 3

3 Intended use ................................................................................................................................................ 3

4 Environment ................................................................................................................................................ 44.1 ABB devices ..................................................................................................................................... 4

5 Product description ...................................................................................................................................... 55.1 Control elements .............................................................................................................................. 55.2 Feature ............................................................................................................................................. 65.3 Terminal description ......................................................................................................................... 75.4 Lock type and connection .............................................................................................................. 10

6 Technical data ........................................................................................................................................... 11

7 Mounting/Installation .................................................................................................................................. 127.1 Requirement for the electrician ...................................................................................................... 127.2 Mounting ........................................................................................................................................ 13

7.2.1 Flush-mounted installation ............................................................................................................. 147.2.2 Replacing the nameplate ................................................................................................................ 167.2.3 Installation situations ...................................................................................................................... 17

8 Commissioning .......................................................................................................................................... 188.1 Building outdoor station .................................................................................................................. 18

8.1.1 Enter system setting of building OS ............................................................................................... 188.1.2 Engineering setting ......................................................................................................................... 198.1.3 Access control setting .................................................................................................................... 218.1.4 System setting ................................................................................................................................ 23

8.2 Villa outdoor station ........................................................................................................................ 26

9 Operation ................................................................................................................................................... 279.1 Calling a resident ........................................................................................................................... 279.2 Calling a guard unit ........................................................................................................................ 299.3 Unlocking ....................................................................................................................................... 309.4 Manage ID/IC cards on indoor station ........................................................................................... 319.5 Use of app to open door................................................................................................................. 33

Notice ................................................................................................................................................................. 34

=== Ende der Liste für Textmarke Inhaltsverzeichnis ===

Page 3: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Notes on the instruction manual

Operating Instructions VER:1.0 │3

Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction manual @ 56\mod_1487567267846_15.docx @ 747508 @ 1 @ 1

1 Notes on the instruction manual

Pos: 8 /CNDEX/00 Warning/Txt_Notes on the instruction manual @ 62\mod_1496802824525_15.docx @ 786157 @ @ 1

Please read through this manual carefully and observe the information it contains. This willassist you in preventing injuries and damage to property, and ensure both reliable operation anda long service life for the device.

Please keep this manual in a safe place.

If you pass the device on, also pass on this manual along with it.

ABB accepts no liability for any failure to observe the instructions in this manual.

Pos: 10 /CNDEX/01 Heading/1. Heading/Heading_Safety @ 56\mod_1487743565314_15.docx @ 749894 @ 1 @ 1

2 Safety

Pos: 11 /CNDEX/00 Warning/Warning_Electric voltage_Dangerous currents @ 56\mod_1487741007782_15.docx @ 749637 @ @ 1

WarningElectric voltage!Dangerous currents flow through the body when coming into direct or indirectcontact with live components.This can result in electric shock, burns or even death.– Disconnect the mains power supply prior to installation and/or disassembly!– Permit work on the 110-240 V supply system to be performed only by

specialist staff!

Pos: 13 /CNDEX/01 Heading/1. Heading/Heading_Intended use @ 56\mod_1487743332845_15.docx @ 749831 @ 1 @ 1

3 Intended use

Pos: 14 /CNDEX/02 Intended use/Intended use_H8137xPx-S_H8137xK-S_OS @ 62\mod_1495605970898_15.docx @ 784034 @ @ 1

Building outdoor station with display, transponder and keypad serves as end device forcommunication with the indoor station or guard unit. Support door communication, call guardunit, unlock by passwords / cards and other functions. Suitable for flush-mounted installation.

Villa outdoor station with transponder and push-button(s) serves as end device forcommunication with the indoor station or guard unit. Support door communication, call guardunit, unlock by passwords / cards and other functions. Suitable for flush-mounted installation

Pos: 15 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

Page 4: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Environment

Operating Instructions VER:1.0 │4

Pos: 17 /CNDEX/01 Heading/1. Heading/Heading_Environment @ 62\mod_1496803173718_15.docx @ 786200 @ 1 @ 1

4 Environment

Pos: 18 /CNDEX/00 Warning/Note_Environment @ 62\mod_1496803082333_15.docx @ 786178 @ @ 1

Consider the protection of the environment!Used electric and electronic devices must not be disposed of with householdwaste.– The device contains valuable raw materials that can be recycled. Therefore,

dispose of the device at the appropriate collecting facility.

Pos: 19 /CNDEX/01 Heading/1.1 Heading/Heading_ABB devices @ 62\mod_1496803248336_15.docx @ 786222 @ 2 @ 1

4.1 ABB devicesPos: 20 /CNDEX/00 Warning/Txt_ABB devices_Environment @ 56\mod_1487743585555_15.docx @ 749915 @ 12 @ 1

All packaging materials and devices from ABB bear the markings and test seals for properdisposal. Always dispose of the packing materials and electric devices and their components viaan authorized collection facility or disposal company.

ABB products meet the legal requirements, in particular the laws governing electronic andelectrical devices and the REACH ordinance.

(EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS)

(EU-REACH ordinance and law for the implementation of the ordinance (EG) No.1907/2006)

Pos: 21 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

Page 5: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Product description

Operating Instructions VER:1.0 │5

Pos: 23 /CNDEX/01 Heading/1. Heading/Heading_Product description @ 56\mod_1487644182664_15.docx @ 747986 @ 1 @ 1

5 Product description

Pos: 24 /CNDEX/01 Heading/1.1 Heading/Heading_Control elements @ 56\mod_1487747434664_15.docx @ 750030 @ 2 @ 1

5.1 Control elementsPos: 25 /CNDEX/03 Front overview/Control elements_H8137xPx-S_H8137xK-S_OS @ 57\mod_1488952981678_15.docx @ 759737 @ @ 1

Fig. 1: Control elements

No. Function

1 Camera

2 White LED (total 6 pcs)

3 Light sensor

4 Speaker and microphone integration

5 Display module with ID/IC card reader

6 Keypad

7 End strip

8 Round push-button

9 Nameplate (this silk-screen means built-in ID/IC card reading function)

Tab.1: Description

Pos: 26 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

1 2

3

4

5

6

7

89

Page 6: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Product description

Operating Instructions VER:1.0 │6

Pos: 27 /CNDEX/01 Heading/1.1 Heading/Heading_Feature @ 56\mod_1487747498194_15.docx @ 750051 @ 2 @ 1

5.2 FeaturePos: 28 /CNDEX/04 Feature/Feature_H8137xPx-S_H8137xK-S_OS @ 57\mod_1488953233070_15.docx @ 759757 @ @ 1

■ 3 mm stainless steel frame■ Scratch and fire resistant finish■ 1m pixel high definition camera with wide detection angle (H 86°,V 67°, D 130°)■ Anti-fog design camera with built-in heater■ Built-in lighting and automatic backlight ensure a clear view at night■ Support 802.3af POE and directly stand-alone power supply■ Open the door with public/private password■ Open the door with card

– For building outdoor station, 2,000 cards for outdoor station and 40,000 for gate station– For villa outdoor station, 300 cards

■ 2 options for built-in RFID proximity reader: ID card or IC/NFC card■ Support of Wiegand output to integrate with 3rd party access control system■ Support of 2 locks connection■ Support of door status detection■ Support of exit button to release the lock■ Support of elevator calling after door is released■ Forward all the calls to guard unit in security mode■ Customized welcome message on outdoor station display

Pos: 29 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

Page 7: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Product description

Operating Instructions VER:1.0 │7

Pos: 30 /CNDEX/01 Heading/1.1 Heading/Heading_Terminal description @ 56\mod_1487747555712_15.docx @ 750072 @ 2 @ 1

5.3 Terminal descriptionPos: 31 /CNDEX/05 Terminal description/Terminal description_H8137xPx-S_H8137xK-S_OS @ 57\mod_1488953435060_15.docx @ 759777 @ @ 1

Fig. 2: Terminal description of audio part

No. Function

1 USB connector for software updating from PC.

2Boot buttonPress and hold this button for 3 s to enter upgrading mode when the power is on.

3

Set buttonPress and hold this button for 3 s to enter configuration mode when the power is on.And press and hold this button for 5 s to restore to factory setting after the power ison.

4 Connector for software updating of this module

5 Connector for sensor used for door status detection

6 Connector for exit push-button

7 Connector for next module

8 Plug-in clamps (COM-NC-NO) for floating output, door opener (30 VAC/DC 1A)

9 Plug-in clamps (LOCK-GND) for door opener (18V 4A impulsive, 250 mA holding)

10 Plug-in clamps (DC+-GND) for standalone power supply

Tab.2: Description

Connector

SET BOOT

1

4

567

8910

2

3

Prog.

Connector

Connector

Connector

Upgrade

H8137xPx-SH8137xK-S

Page 8: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Product description

Operating Instructions VER:1.0 │8

Fig. 3: Terminal description of pushbutton module

No. Function

1 Program button

2 Connector for previous module

3 Connector for software updating of this module

4Connector for Wiegand outputIt supports 26 bits (default) and 34 bits.

5 Connector for next module

Tab.3: Description

1

23

5

4

H8137xPx-S

Page 9: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Product description

Operating Instructions VER:1.0 │9

Fig. 4: Terminal description of display and keypad module

No. Function

1 Program button

2 Connector for previous module

3 Connector for software updating of this module

4 USB connector (reserved)

5 Connector for next module

6Connector for Wiegand outputIt supports 26 bits (default) and 34 bits.

Tab.4: Description

Pos: 32 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

1

23

5

6

4

SET BOO T

1

23

5

4

H8137xK-S

Page 10: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Product description

Operating Instructions VER:1.0 │10

Pos: 33 /CNDEX/01 Heading/1.1 Heading/Heading_Lock type and connection @ 56\mod_1487747624072_15.docx @ 750093 @ 2 @ 1

5.4 Lock type and connectionPos: 34 /CNDEX/05 Terminal description/Lock type_OS @ 56\mod_1487645786193_15.docx @ 748070 @ @ 1

Lock type Operation type Voltage Wiring type

Electrical strike lock, 12V Power on to open 12 VDC/AC

Type AType B

Electrical strike lock, 24V Power on to open 24 VDC/AC Type B

Electrical rim lock, 12 V Power on to open 12 VDCType AType B

Electrical mortise lock Power off to open 12 VDC Type C

Magnetic lock Power off to open 12/24 V DC Type C

Tab.5: Lock typePos: 35 /CNDEX/05 Terminal description/Lock connection_H8137xPx-S_H8137xK-S_OS @ 57\mod_1488954276165_15.docx @ 759797 @ @ 1

Fig. 5: Lock connectionPos: 36 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

DC+

GND

LOCK

NC

COM

NO

DC+

GND

LOCK

NC

COM

NO

DC+

GND

LOCK

NC

COM

NO

PS

Type A Type B Type C

+-

PS+-

Page 11: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Technical data

Operating Instructions VER:1.0 │11

Pos: 38 /CNDEX/01 Heading/1. Heading/Heading_Technical data @ 56\mod_1487744734167_15.docx @ 749958 @ 1 @ 1

6 Technical data

Pos: 39 /CNDEX/06 Technical data/Technical data_H8137xPx-S_H8137xK-S_OS @ 57\mod_1488955388730_15.docx @ 759817 @ @ 1

Designation Value

Operating temperature -40 °C - +70 °C

Protection (cover frame assembled) dustproof and waterproof as IP 54, vandal proofas IK 07

Power supply, door opener (Lock-GND) 18 V 4 A impulsive, 250 mA holding

Floating supply, door opener (COM-NC-NO) 30 VAC/DC 1A

Working voltage 27 VDC

DimensionH8137xPx-S: 273.8 mm x 135 mm x 48.5 mmH8137xK-S: 346.8 mm x 135 mm x 48.5 mm

Tab.6: Technical dataPos: 40 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

Page 12: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Mounting/Installation

Operating Instructions VER:1.0 │12

Pos: 42 /CNDEX/01 Heading/1. Heading/Heading_Mounting/Installation @ 56\mod_1487743369641_15.docx @ 749852 @ 1 @ 1

7 Mounting/Installation

Pos: 43 /CNDEX/00 Warning/Warning_Electric voltage_Dangerous currents @ 56\mod_1487741007782_15.docx @ 749637 @ @ 1

WarningElectric voltage!Dangerous currents flow through the body when coming into direct or indirectcontact with live components.This can result in electric shock, burns or even death.– Disconnect the mains power supply prior to installation and/or disassembly!– Permit work on the 110-240 V supply system to be performed only by

specialist staff!

Pos: 44 /CNDEX/01 Heading/1.1 Heading/Heading_Requirement for electrician @ 56\mod_1487743099110_15.docx @ 749789 @ 2 @ 1

7.1 Requirement for the electricianPos: 45 /CNDEX/00 Warning/Warning_Electric voltage_Install the device @ 56\mod_1487743205578_15.docx @ 749810 @ @ 1

WarningElectric voltage!Install the device only if you have the necessary electrical engineeringknowledge and experience.– Incorrect installation endangers your life and that of the user of the electrical

system.– Incorrect installation can cause serious damage to property, e.g. due to fire.

The minimum necessary expert knowledge and requirements for the installationare as follows:– Apply the "five safety rules" (DIN VDE 0105, EN 50110):

1. Disconnect2. Secure against being re-connected3. Ensure there is no voltage4. Connect to earth and short-circuit5. Cover or barricade adjacent live parts.

– Use suitable personal protective clothing.– Use only suitable tools and measuring devices.– Check the type of supply network (TN system, IT system, TT system) to

secure the following power supply conditions (classic connection to ground,protective grounding, necessary additional measures, etc.).

Pos: 46 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

Page 13: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Mounting/Installation

Operating Instructions VER:1.0 │13

Pos: 47 /CNDEX/01 Heading/1.1 Heading/Heading_Mounting @ 56\mod_1487742836665_15.docx @ 749745 @ 2 @ 1

7.2 MountingPos: 48 /CNDEX/07 Mounting/Installation/Preparation_OS @ 56\mod_1487742936063_15.docx @ 749767 @ @ 1

Use gloves to protect yourself from being cut.

Fig. 6: PreparationPos: 49 /CNDEX/07 Mounting/Installation/Wiring_H8137xPx-S_H8137xK-S_OS @ 58\mod_1489113964205_15.docx @ 765047 @ @ 1

Fig. 7: WiringPos: 50 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

DC+ GND

SET BOOT

LOCK COM NC NO

LAN

Page 14: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Mounting/Installation

Operating Instructions VER:1.0 │14

Pos: 51 /CNDEX/01 Heading/1.1.1 Heading/Heading_Flush-mounted installation @ 56\mod_1487748835312_15.docx @ 750174 @ 3 @ 1

7.2.1 Flush-mounted installationPos: 52 /CNDEX/07 Mounting/Installation/Product dimension_H8137xPx-S_H8137xK-S_OS @ 57\mod_1488957202224_15.docx @ 759900 @ @ 1

Fig. 8: Product dimensionPos: 53 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

135 mm

135 mm

48.5 mm

48.5 mm

273.

8m

m34

6.8

mm

TOP

110 mm

41.5 mm

262.

5m

m

110 mm

335.

5m

m

41.5 mm

H8137xPx-S

H8137xK-S

Page 15: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Mounting/Installation

Operating Instructions VER:1.0 │15

Pos: 54 /CNDEX/07 Mounting/Installation/Flush-mounted installation_H8137xPx-S_H8137xK-S_OS @ 57\mod_1488957107080_15.docx @ 759940 @ @ 1

Fig. 9: Flush-mounted installationPos: 55 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

H8137xPx-SH8137xK-S

Page 16: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Mounting/Installation

Operating Instructions VER:1.0 │16

Pos: 56 /CNDEX/01 Heading/1.1.1 Heading/Heading_Replace the nameplate @ 56\mod_1487748988144_15.docx @ 750237 @ 3 @ 1

7.2.2 Replacing the nameplatePos: 57 /CNDEX/07 Mounting/Installation/Replace the nameplate_H8137xPx-S_Villa OS @ 57\mod_1488958428077_15.docx @ 759960 @ @ 1

Fig. 10: Replace the nameplate

Pos: 58 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

2

H8137xPx-S

0102

1

Page 17: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Mounting/Installation

Operating Instructions VER:1.0 │17

Pos: 59 /CNDEX/01 Heading/1.1.1 Heading/Heading_Installation situations @ 56\mod_1487749033946_15.docx @ 750258 @ 3 @ 1

7.2.3 Installation situationsPos: 60 /CNDEX/00 Warning/Note_Installation situations @ 56\mod_1487743694622_15.docx @ 749937 @ @ 1

NoteThe following installation situations must be avoided without fail to ensurepicture quality.– Direct light– Direct sunlight– Extremely bright picture background– Highly reflective walls on the opposite side of the door station– Lamps or direct light sources

Pos: 61 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

Page 18: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Commissioning

Operating Instructions VER:1.0 │18

Pos: 63 /CNDEX/01 Heading/1. Heading/Heading_Commissioning @ 57\mod_1487828936105_15.docx @ 751257 @ 1 @ 1

8 Commissioning

Pos: 64 /CNDEX/01 Heading/1.1 Heading/Heading_Building outdoor station @ 57\mod_1488958895114_15.docx @ 760010 @ 2 @ 1

8.1 Building outdoor stationPos: 65 /CNDEX/01 Heading/1.1.1 Heading/Heading_Enter system setting of building OS @ 62\mod_1496805537569_15.docx @ 786317 @ 3 @ 1

8.1.1 Enter system setting of building OSPos: 66 /CNDEX/08 Commissioning/Enter system setting_H8137xK-S_Building OS @ 62\mod_1496805652119_15.docx @ 786338 @ @ 1

Fig. 11: Enter system setting

On standby mode, press [#*] + system code + [#] to enter the system setting.

Default system code is "345678".

Pos: 67 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

******#*

Page 19: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Commissioning

Operating Instructions VER:1.0 │19

Pos: 68 /CNDEX/01 Heading/1.1.1 Heading/Heading_Engineering setting @ 62\mod_1496805803238_15.docx @ 786358 @ 3 @ 1

8.1.2 Engineering settingPos: 69 /CNDEX/08 Commissioning/Engineering setting_H8137xK-S_Building OS @ 62\mod_1496805869896_15.docx @ 786379 @ @ 1

Set device type

OS = outdoor station, GS = gate station

Fig. 12: Set device type

Set device number

Fig. 13: Set device number

Set block information

If GS, set block digits here; if OS, set block number here.

Fig. 14: Set block information

Set IS digits

Fig. 15: Set IS digits

EngineeringDevice attr.

Device attr.Device type

Device type

GSOS

MenuEngineering

EngineeringDevice attr. OS

Device attr.Device No.

Device No.

01

Input GS No.

01

MenuEngineering OS/GSOS/GS OS

GS

EngineeringSystem attr.

System attr.Block digits

Block digits:

2 digits3 digits

1 digit

System attr.Block No.

Block No.

001

GS

OS

MenuEngineering

EngineeringSystem attr.

System attr.IS digits

IS digits:

4 digits3 digits

IS digits:

4 digits3 digits0 digitsGS

OSOS/GSMenuEngineering

Page 20: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Commissioning

Operating Instructions VER:1.0 │20

Set default GU

Fig. 16: Set default GU

Set system password

Fig. 17: Set system password

Pos: 70 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

EngineeringSystem attr.

System attr.Default GU

Guard type: 0

Guard No.: 01

0:GU 1:PCOS/GSMenuEngineering

EngineeringSystem attr.

System attr.System pwd.OS/GS

(Default pwd. = 345678)

MenuEngineering

Page 21: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Commissioning

Operating Instructions VER:1.0 │21

Pos: 71 /CNDEX/01 Heading/1.1.1 Heading/Heading_Access control setting @ 62\mod_1496806038922_15.docx @ 786399 @ 3 @ 1

8.1.3 Access control settingPos: 72 /CNDEX/08 Commissioning/Access control setting_H8137xK-S_Building OS @ 62\mod_1496806114114_15.docx @ 786420 @ @ 1

Access control password setting

Fig. 18: Access control password setting

Card mode setting

Fig. 19: Card mode setting

User card management

Fig. 20: User card management

MenuAccess control

Access controlPwd. setting

Pwd. settingNew pub. pwd.

Pwd. settingEnable pub.

Pwd. settingEnable pvt.

New pwd:

******

Enable pub.

ONOFF

Enable pvt.

ONOFF

Card settingCard mode

Card mode

CustomizationStandard

Access controlCard setting

MenuAccess control

Card settingUser card

User cardAdd

User cardDelete

User cardDelete all

Access controlCard setting

MenuAccess control

Page 22: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Commissioning

Operating Instructions VER:1.0 │22

Patrol card management

Fig. 21: Patrol card management

Card information copy to other outdoor station

Fig. 22: Card information copy to other outdoor station

Pos: 73 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

Card No.

Del. one cardPress # confirm

Delete one

Del. one cardPress # confirm

Card settingPatrol card

Patrol cardAdd

Patrol cardUnlock setting

Patrol cardDelete

Patrol cardDelete all

Unlock setting

ONOFF

Access controlCard setting

Confirm?Delete all cards

Del. one cardPress # confirm

MenuAccess control

Card settingCopy

Access controlCard setting 02

Destn. OS No.

Del. one card02

Destn. OS No.

Copying

MenuAccess control

Page 23: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Commissioning

Operating Instructions VER:1.0 │23

Pos: 74 /CNDEX/01 Heading/1.1.1 Heading/Heading_System setting @ 57\mod_1488959631505_15.docx @ 760166 @ 3 @ 1

8.1.4 System settingPos: 75 /CNDEX/08 Commissioning/System setting_H8137xK-S_Building OS @ 62\mod_1496806271172_15.docx @ 786440 @ @ 1

Set volume

Fig. 23: Set volume

Set date and time

Fig. 24: Set date and time

Set languages

Fig. 25: Set languages

Set Wiegand

Fig. 26: Set Wiegand

Choose default lock

Fig. 27: Choose default lock

MenuSystem setting

System settingVolume

Voice volume

MediumHigh

LowVolumeVoice volume

VolumeKey tone

Key tone

ONOFF

2016-09-06

Press # confirm

15:55

MenuSystem setting

System settingDate & time

MenuSystem setting

System settingLanuage

Language

English中⽂

MenuSystem setting

System settingWiegand

Wiegand

26bit34bit

OFF

MenuSystem setting

System settingChoose door

Choose door

2nd (NC-NO-C)1st (LOCK-GND)

Page 24: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Commissioning

Operating Instructions VER:1.0 │24

Set unlock time

Fig. 28: Set unlock time

Set door alarm

Fig. 29: Set door alarm

Set temper alarm

Fig. 30: Set temper alarm

Set lift control

Fig. 31: Set lift control

Set anti-flicker

Fig. 32: Set anti-flicker

MenuSystem setting Choose door

Unlock time

Press # confirm05s

System settingUnlock time

Unlock time

2nd (NC-NO-C)1st (LOCK-GND)

MenuSystem setting Choose doorUnlock time

System settingDoor alarm

Door alarm

ONOFF

MenuSystem setting Choose doorUnlock timeDoor alarm

System settingTamper alarm

Tamper alarm

ONOFF

MenuSystem setting Choose doorUnlock timeDoor alarm

Floor No.

Press # confirm01

Block No.

001

System settingLift setting

Lift settingEnable lift

Lift settingFloor No.

Lift settingBlock No.

Enable lift

ONOFF

MenuSystem setting

System settingAnti-flicker

Anti-flicker

60Hz50Hz

Page 25: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Commissioning

Operating Instructions VER:1.0 │25

Restore system setting

Fig. 33: Restore system setting

Guide and version

Fig. 34: Guide and version

Forward to GU

Fig. 35: Forward to GU

Pos: 76 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

MenuSystem setting Anti-flicker

Restore

Press # confirm

System settingRestore

MenuSystem setting

System settingHelp

I. Mx_1.14_161227

LCD_1.12_161205KP_2.07_151116

Ext_1.05_160905

HelpGuide

Station no. Eg.:0101

1. Input Indoor

HelpVersion

MenuSystem setting Help

System settingForward to GU

Forward to GU

ONOFF

Page 26: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Commissioning

Operating Instructions VER:1.0 │26

Pos: 77 /CNDEX/01 Heading/1.1 Heading/Heading_Villa outdoor station @ 58\mod_1489108711728_15.docx @ 764767 @ 2 @ 1

8.2 Villa outdoor stationPos: 78 /CNDEX/08 Commissioning/Find details in the system manual @ 62\mod_1497234325447_15.docx @ 788858 @ @ 1

Please find details in the system manual.Pos: 79 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

Page 27: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Operation

Operating Instructions VER:1.0 │27

Pos: 81 /CNDEX/01 Heading/1. Heading/Heading_Operation @ 56\mod_1487743450854_15.docx @ 749873 @ 1 @ 1

9 Operation

Pos: 82 /CNDEX/01 Heading/1.1 Heading/Heading_Calling a resident @ 57\mod_1488959170295_15.docx @ 760031 @ 2 @ 1

9.1 Calling a residentPos: 83 /CNDEX/09 Operation/Calling a resident_OS_H8137xPx-S_H8137xK-S @ 57\mod_1488960023033_15.docx @ 760301 @ @ 1

Fig. 36: Calling a resident

Villa outdoor station H8137xPx-s

Press the first button to start a call. Press again to end the call.

If there is no answer from the resident within 30 s, the call ends automatically.

Building outdoor station H8137xK-S

If the device is set as OS (outdoor station), enter the room number and press the call button.

If the device is set as GS (gate station), enter the building number + room number and press thecall button.

Press * to end the call.

If there is no answer from the resident within 30 s, the call ends automatically.

H8137xPx-S H8137xK-S

IS no.:

0501

Device type=OS

Device type=GS

IS no.:

2220501

Page 28: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Operation

Operating Instructions VER:1.0 │28

Forward to GU (only available for H8137xK-S)

Fig. 37: Forward to GU

If the device enables the function "Forward to GU", all the calls from the visitors will betransferred to the guard unit.

Pos: 84 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

MenuSystem setting

System settingForward to GU

Forward to GU

ONOFF

Page 29: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Operation

Operating Instructions VER:1.0 │29

Pos: 85 /CNDEX/01 Heading/1.1 Heading/Heading_Calling a guard unit @ 57\mod_1488959501436_15.docx @ 760104 @ 2 @ 1

9.2 Calling a guard unitPos: 86 /CNDEX/09 Operation/Calling a guard unit_H8137xPx-S_H8137xK-S_OS @ 57\mod_1488960708204_15.docx @ 760381 @ @ 1

Fig. 38: Calling a guard unit

Villa outdoor station H8137xPx-S

Press the second button to call the guard unit. Press again to end the call.

If there is no answer from the guard unit within 30 s, the call ends automatically.

The second button can be set as calling PC guard through the indoor station.

Building outdoor station H8137xK-S

Press to call the guard unit. Press * to end the call.

If there is no answer from the resident within 30 s, the call ends automatically.

Pos: 87 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

H8137xPx-S H8137xK-S

Page 30: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Operation

Operating Instructions VER:1.0 │30

Pos: 88 /CNDEX/01 Heading/1.1 Heading/Heading_Unlock @ 57\mod_1488959574522_15.docx @ 760125 @ 2 @ 1

9.3 UnlockingPos: 89 /CNDEX/09 Operation/Unlock_H8137xK-S_Building OS @ 57\mod_1488960772354_15.docx @ 760401 @ @ 1

Fig. 39: Unlocking

Unlock by swiping a card

Swiping a registered ID/IC card near the card zone to unlock.

Unlock by pushing the button

Press an exit button to unlock if "Exit" port of outdoor station is connected to the exit button.

Unlock by public password

[#] + public password + [#] (Default public password is "201007". )

This function is disabled by default. See chapter "Access control setting" to enable the function.

See product manual of indoor station to change the password.

Unlock by user password:

Device type = OS

[*] + room number + [#] + user password + [#]

(Default user password is "123456", this is only used to set a new password at the first time)

Device type = GS

[*] + building number + [#] + room number + [#] + user password + [#]

This function is disabled by default. See chapter "Access control setting" to enable the function.

See product manual of the indoor station to change the password.Pos: 90 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

Door open

Unlocking...

Page 31: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Operation

Operating Instructions VER:1.0 │31

Pos: 91 /CNDEX/01 Heading/1.1 Heading/Heading_Manage ID/IC cards on indoor station @ 58\mod_1489111024283_15.docx @ 764931 @ 3 @ 1

9.4 Manage ID/IC cards on indoor stationPos: 92 /CNDEX/09 Operation/Manage cards by indoor station_H8137xPx-S_Villa OS @ 58\mod_1489111576489_15.docx @ 764952 @ @ 1

NotePlease assign the outdoor station to a specific apartment first before configuringthe ID/IC card.

Fig. 40: Manage ID/IC cards on indoor station

■ Press on the indoor station■ Click "Door Entry" then click "Select".■ Click "Private OS" and enter the 6-digit private password. (Default is "123456".)

Page 32: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Operation

Operating Instructions VER:1.0 │32

Fig. 41

Register new ID/IC cards

During the process, the push-button module lights up yellow, swipe the ID/IC cards to register; ifsuccessful, the pushbutton module lights up green.

Delete existing ID/IC cards

During the process, the push-button module flashes yellow, swipe the ID/IC cards to delete; ifsuccessful, the push-button module lights up green.

Delete all existing ID/IC cards

Click to delete all existing ID/IC cards. If successful, the push-button module lights up green.

During the process of card registering or card deletion, the push-button module will light up orflash. You can press the 1st round push-button to quit the process.

Technical data of ID card

Work frequency Standard Support ID card protocol

125KHz ISO18000-2 EM4100, EM4205, EM4305, EM4450, TK4100,T5567/T5577

Table 7

Technical data of IC card

Designation Value

Work frequency 13.56 MHzStandard ISO14443ASupport card Mifare One S50/S70, etc.Output format Wiegand 26/34 bitSupport NFC device Mostly NFC mobile. (Test is required before using)

Table 8Pos: 93 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

Page 33: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Operation

Operating Instructions VER:1.0 │33

Pos: 94 /CNDEX/01 Heading/1.1 Heading/Heading_Using app to open door @ 58\mod_1489112456064_15.docx @ 764972 @ 3 @ 1

9.5 Use of app to open doorPos: 95 /CNDEX/09 Operation/Using app to open door_OS_H8137xPx-S @ 58\mod_1489112520382_15.docx @ 764993 @ @ 1

Push-button module with NFC can be used for opening the door. Programming is carried out onthe indoor station. Additional devices are not required for commissioning.

To the play store

(https://play.goole.com/store/apps/details?id=com.abb.allegro3_nfcdooropener&hl=en)

[1] Download and install the ABB door opener app from the Google Play Store.[2] Turn on the NFC function of your mobile device.[3] Enter the setting mode of the round push-button module.[4] Start using the NFC app on your mobile device.[5] Set up your mobile device as a new user card.[6] Configure your personal settings.

Fig. 42: Download APP

Fig. 43: Registration

Pos: 96 /CNDEX/99 Auxiliary tools/++++++++++++++ page break +++++++++++++++ @ 57\mod_1487814735946_0.docx @ 750979 @ @ 1

Page 34: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Notice

Operating Instructions VER:1.0 │34

Pos: 98 /CNDEX/01 Heading/1. Heading/Heading_Notice @ 62\mod_1496803447943_15.docx @ 786244 @ 1 @ 1

Notice

Pos: 99 /CNDEX/00 Warning/Txt_Notice @ 56\mod_1487658095029_15.docx @ 748686 @ 1 @ 1

We reserve the right to at all times make technical changes as well as changes to the contentsof this document without prior notice.

The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts noresponsibility for possible errors or incompleteness in this document.

We reserve all rights to this document and the topics and illustrations contained therein. Thedocument and its contents, or excerpts thereof, must not be reproduced, transmitted or reusedby third parties without prior written consent by ABB.

=== Ende der Liste für Textmarke Inhalt ===

Page 35: mod 1500620160705 0.docx @ 801123 @ @ 1 …...Notes on the instruction manual Operating Instructions VER:1.0 │3 Pos: 7 /CNDEX/01 Heading/1. Heading/Heading_Notes on the instruction

Pos: 102.1 /CNDEX/00_Backcover/modules/Head @ 63\mod_1500448863944_15.docx @ 799967 @ @ 1

Contact us NoticeWe reserve the right to at all timesmake technical changes as well aschanges to the contents of thisdocument without prior notice.The detailed specifications agreedupon apply for orders. ABB acceptsno responsibility for possible errorsor incompleteness in this document.

We reserve all rights to thisdocument and the topics andillustrations contained therein. Thedocument and its contents, orextracts thereof, must not bereproduced, transmitted or reusedby third parties without prior writtenconsent by ABB

Ope

ratin

gIn

stru

ctio

ns2T

MD

0417

00D

0042

│01

.08.

2017

ABB (United Arab Emirates)Industries(L.L.C)P.O.Box 11070 Dubai-UAET : +971 4 3147 586F : +971 4 3401 541

ABB (Vietnam) Ltd.Km 9 National Highway 1A ,Hoang Liet, Hoang Mai, Hanoi,VietnamT : +84 4 3861 1010F : +84 4 3861 1009

ABB (Turkey) Eletrik San.ASABB Elektrik Sanayi AS. OrganizeSanayi Bolgesi 2 CaddeNo: 16 Y. Dudullu-IstanbulT : +90 216 528 2281F : +90 216 528 2945

ABB (KSA) Electrical IndustriesCo. Ltd.P.O.Box 325841, Riyadh 11371T : +966 1 1484 5600F : +966 1 1206 7609

ABB (Thailand) Ltd.161/1 SG Tower, 1st-4th Floor, SoiMahadlekluang 3, Rajdamri Road,Lumpini, Pathumwan Bangkok10330, ThailandT : +66 2 6651 000F : +66 2 6651 043

ABB (Russia) Ltd.3121 Wiring Accessories30/1 bld.2, Obrucheva str. RUT : +7 495 777 2220F : +7 495 777 2220

ABB (Korea) Ltd.Oksan Bldg, 10th Fl. 157-33Samsung-dong, Gangnam-gu,135-090, Seoul, KoreaT : +82 2 5283 177F : +82 2 5282 350

ABB Malaysia Sdn BhdBlock A, Level 2, Lot 608, JalanSS13/IK 47500 Subang JayaSelangorT : +60 3 5628 4888F : +60 3 5635 8200

ABB Global Marketing - LebanonDown Town, Beirut, ebanonT : +961 1983 724/5F : +961 1983 723

ABB (Hong Kong) Ltd.3 Dai Hei Street, Tai Po IndustrialEstate, Tai po, Hong KongT : +852 2 9293 912F : +852 2 9293 505

ABB (India) Ltd.Plot No.1, Sector-1B,I.I.E.SIDCUL,Haridwar-249403.IndiaT : +91 133 423 5447F : +91 133 423 5449

ABB Pte. Ltd.2 Ayer Rajah Crescent,Singapore 139935T: + 65 6 7765 711F: + 65 6 7780 222

ABB Australia Pty Ltd.601 Blackburn Road3168, Notting Hill, Victoria,AustraliaT : +61 3 8577 7139F : +61 3 9545 0415

www.abb.com

Approvals and Compliances

Pos: 102.2 /CNDEX/00_Backcover/modules/Copyright @ 63\mod_1500449850477_15.docx @ 799987 @ @ 1

=== Ende der Liste für Textmarke Rueckseite ===