mlm 104 faceplates installation guide - extron€¦ · mlm 104 laap template 2.8" (7.1 cm)...

10
1 MLM 104 Faceplates • Installation Guide MLM 104 Faceplates Installation Guide MLM 104 Faceplates This guide provides instructions for installing the following Extron MediaLink Mounting Options faceplates, which are designed for use with MLC 104 IP Plus MediaLink Controllers. The MLM 104 L, MLM 104 2GWP, or MLM 104 4GWP faceplate is shipped with the MLC 104 IP Plus controller, depending on the controller configuration that is ordered. The rest of the mounting options described below may be ordered separately as replacements, or for use with an MLC 104 IP Plus that is ordered without a faceplate. MLM 104 L — A low-profile, 3.15" H x 6.50" W (8.0 cm H x 16.5 cm W) lectern/furniture-mounting faceplate. This faceplate is required when you are mounting an MLC 104 IP Plus using an optional UCM RAAP or UCM 10X8P mounting kit. Part numbers: 70-357-02 (black), 70-357-03 (white), 70-357-05 (RAL9010 white) MLM 104 LAAP — A low-profile, 3.15" H x 10.00" W (8.0 cm H x 25.40 cm W) lectern/furniture-mounting faceplate with an opening that accommodates four single-space AAPs Part numbers: 70-358-02 (black), 70-358-03 (white), 70-358-05 (RAL9010 white) 68-878-01, Rev. D 08 07

Upload: others

Post on 15-Oct-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MLM 104 Faceplates Installation Guide - Extron€¦ · MLM 104 LAAP template 2.8" (7.1 cm) 7.9" (20.1 cm) SURFACE CUT-OUT AREA FOR FURNITURE MOUNT 10" (25.4 cm) Cut-Out Template for

1MLM 104 Faceplates • Installation Guide

MLM 104 Faceplates Installation Guide

MLM 104 FaceplatesThis guide provides instructions for installing the following Extron MediaLink™

Mounting Options faceplates, which are designed for use with MLC 104 IP PlusMediaLink Controllers.

The MLM 104 L, MLM 104 2GWP, or MLM 104 4GWP faceplate is shippedwith the MLC 104 IP Plus controller, depending on the controller configurationthat is ordered. The rest of the mounting options described below may beordered separately as replacements, or for use with an MLC 104 IP Plus that isordered without a faceplate.

• MLM 104 L — A low-profile, 3.15" H x 6.50" W (8.0 cm H x 16.5 cm W)lectern/furniture-mounting faceplate. This faceplate is required when you aremounting an MLC 104 IP Plus using an optional UCM RAAP or UCM 10X8Pmounting kit.Part numbers: 70-357-02 (black), 70-357-03 (white), 70-357-05 (RAL9010 white)

• MLM 104 LAAP — A low-profile, 3.15" H x 10.00" W (8.0 cm H x 25.40 cm W)lectern/furniture-mounting faceplate with an opening that accommodatesfour single-space AAPsPart numbers: 70-358-02 (black), 70-358-03 (white), 70-358-05 (RAL9010 white)

68-878-01, Rev. D08 07

Page 2: MLM 104 Faceplates Installation Guide - Extron€¦ · MLM 104 LAAP template 2.8" (7.1 cm) 7.9" (20.1 cm) SURFACE CUT-OUT AREA FOR FURNITURE MOUNT 10" (25.4 cm) Cut-Out Template for

MLM 104 Faceplates Installation Guide, cont’d

MLM 104 Faceplates • Installation Guide2

• MLM 104 2GWP — A two-gang (4.50" H x 4.60" W [11.43 cm H x 11.68 cm W])faceplate that can be mounted to a mud ring (mounting bracket), an ExtronSurface Mount Box, an Extron External Wall Box, or a standard electrical boxPart numbers: 70-378-02 (black), 70-378-03 (white), 70-378-05 (RAL9010 white)

• MLM 104 4GWP — A four-gang (4.50" H x 8.23" W [11.43 cm H x 20.9 cm W])faceplate with an opening that accommodates four single-space AAPs. It canbe mounted to a mud ring, an Extron Surface Mount Box, an Extron ExternalWall Box, or a standard electrical box.Part numbers: 70-379-02 (black), 70-379-03 (white), 70-379-05 (RAL9010 white)

• MLM 104 6GWP— A six-gang (4.50" H x 11.75" W [11.43 cm H x 29.85 cm W])faceplate with two openings that accommodate four single-space AAPs each(eight AAPs total). It can be mounted to a mud ring, an Extron Surface MountBox, an Extron External Wall Box, or a standard electrical box.Part numbers: 70-355-02 (black), 70-355-03 (white), 70-355-05 (RAL9010 white)

Page 3: MLM 104 Faceplates Installation Guide - Extron€¦ · MLM 104 LAAP template 2.8" (7.1 cm) 7.9" (20.1 cm) SURFACE CUT-OUT AREA FOR FURNITURE MOUNT 10" (25.4 cm) Cut-Out Template for

3MLM 104 Faceplates • Installation Guide

Replacing the MLC 104 IP Plus Faceplate with an MLMFaceplate

1. If your MLC controller is already installed in a wall or furniture, remove thefour screws that attach it to its mounting surface (marked a in the diagrambelow), and lift it out.

2. After the MLC has been removed from the wall or furniture, use a smallPhillips screwdriver to remove the four faceplate attachment screws (markedb in the diagram below), and save them for later use.

CAUTION Do not remove the four faceplate screws while the MLC is installed in awall or furniture, or the controller may fall into the wall or furniture.

CONFIG

DISPLAY

VOLUME

ON OFF 1 2 3 4

2

2

2

2

MLC 104 IP PLUS

VCR

DVD

PC

1

1

1

1

3. Lift the faceplate off the MLC 104 IP Plus, as shown below.

OFF

ON

OFF

ON

VCR

DVD

PC

Extron

CONFIG

DISPLAY

VOLUME

1 2 3 4

MLC 104 IP PLUS

Page 4: MLM 104 Faceplates Installation Guide - Extron€¦ · MLM 104 LAAP template 2.8" (7.1 cm) 7.9" (20.1 cm) SURFACE CUT-OUT AREA FOR FURNITURE MOUNT 10" (25.4 cm) Cut-Out Template for

MLM 104 Faceplates Installation Guide, cont’d

MLM 104 Faceplates • Installation Guide4

4. Align the openings in the new MLM faceplate with the controller’s buttons,knob, and LEDs, then place the new faceplate on the MLC 104 IP Plus.

5. Replace the four screws removed in step 2, and hand tighten them.

6. Install the MLC 104 IP Plus controller in a wall or furniture as appropriate.

TemplatesUse one of the following templates as a guide to measure and mark the hole forinstalling the MLM 104 faceplate with an attached MLC 104 IP Plus. (Refer to yourMLC 104 IP User’s Manual for instructions on preparing the mounting site.)

CAUTION These templates are not to scale. Use the dimensions shown in thetemplates as reference guidelines for measuring and drawing the rectanglethat will be cut out.

The MLC controller requires a depth of at least 2.0" (5.1 cm) inside the wall orfurniture.

Page 5: MLM 104 Faceplates Installation Guide - Extron€¦ · MLM 104 LAAP template 2.8" (7.1 cm) 7.9" (20.1 cm) SURFACE CUT-OUT AREA FOR FURNITURE MOUNT 10" (25.4 cm) Cut-Out Template for

5MLM 104 Faceplates • Installation Guide

MLM 104 L and MLC 104 IP Plus L template

.295" (0.75 cm)

.250" (0.64 cm)

6.5" (16.5 cm)

Cut-Out Template for Extron's MLM 104 L and MLC 104 IP Plus L

TEMPLATE IS NOT FULL SIZE.

To install MLC 104 IP Plus and MLM 104 L directly into furniture, cut along this line.

Top Panel

2.8"(7.1 cm)

3.5" (8.9 cm)

SURFACE CUT-OUT AREA FOR FURNITURE MOUNT

3.15" (8.0 cm)

Location of MLC 104 IP Plus

Page 6: MLM 104 Faceplates Installation Guide - Extron€¦ · MLM 104 LAAP template 2.8" (7.1 cm) 7.9" (20.1 cm) SURFACE CUT-OUT AREA FOR FURNITURE MOUNT 10" (25.4 cm) Cut-Out Template for

MLM 104 Faceplates Installation Guide, cont’d

MLM 104 Faceplates • Installation Guide6

MLM 104 LAAP template

2.8"(7.1 cm)

7.9" (20.1 cm)

SURFACE CUT-OUT AREA FOR

FURNITURE MOUNT

10" (25.4 cm)

Cut-Out Template for Extron's MLM 104 LAAP

TEMPLATE IS NOT FULL SIZE.

To install the MLC 104 IP Plusand the MLM 104 LAAP directly into furniture,cut along this line.

Top Panel

Location of MLC 104 IP Plus

3.15" (8.0 cm)

.295" (0.75 cm)

.250" (0.64 cm)

Page 7: MLM 104 Faceplates Installation Guide - Extron€¦ · MLM 104 LAAP template 2.8" (7.1 cm) 7.9" (20.1 cm) SURFACE CUT-OUT AREA FOR FURNITURE MOUNT 10" (25.4 cm) Cut-Out Template for

7MLM 104 Faceplates • Installation Guide

MLM 104 2GWP and MLC 104 IP Plus template

4.6" (11.7 cm)

Cut-Out Template for Extron's MLM 104 2GWP and MLC 104 IP Plus

TEMPLATE IS NOT FULL SIZE.

To install MLC 104 IP Plus and MLM 104 2GWP directly into furniture, cut along this line.

Top Panel

2.8"(7.1 cm)

3.5" (8.9 cm)

SURFACE CUT-OUT AREA FOR FURNITURE MOUNT

4.5" (11.4 cm)

Location of MLC 104 IP Plus

Page 8: MLM 104 Faceplates Installation Guide - Extron€¦ · MLM 104 LAAP template 2.8" (7.1 cm) 7.9" (20.1 cm) SURFACE CUT-OUT AREA FOR FURNITURE MOUNT 10" (25.4 cm) Cut-Out Template for

MLM 104 Faceplates Installation Guide, cont’d

MLM 104 Faceplates • Installation Guide8

MLM 104 4GWP and MLC 104 IP Plus AAP template

2.8"(7.1 cm)

7.1" (18.0 cm)

SURFACE CUT-OUT AREA FOR

FURNITURE MOUNT

8.23"(20.9 cm)

Cut-Out Template for Extron's MLM 104 4GWPand MLC 104 IP Plus AAP

TEMPLATE IS NOT FULL SIZE.

To install the MLC 104 IP Plusand the MLM 104 4GWP directly into furniture,cut along this line.

Top Panel

Location of MLC 104 IP Plus

4.5" (11.4 cm)

Page 9: MLM 104 Faceplates Installation Guide - Extron€¦ · MLM 104 LAAP template 2.8" (7.1 cm) 7.9" (20.1 cm) SURFACE CUT-OUT AREA FOR FURNITURE MOUNT 10" (25.4 cm) Cut-Out Template for

9MLM 104 Faceplates • Installation Guide

2.8"(7.1 cm)

11.0" (27.9 cm)

SURFACE CUT-OUT AREA FOR

FURNITURE MOUNT

Cut-Out Template for Extron's MLM 104 6GWP

TEMPLATE IS NOT FULL SIZE.

Top Panel

Location of MLC 104 IP Plus11.752" (29.85 cm)

To install the MLC 104 IP Plusand the MLM 104 6GWP directly into furniture,cut along this line.

4.5" (11.4 cm)

MLM 104 6GWP template

Page 10: MLM 104 Faceplates Installation Guide - Extron€¦ · MLM 104 LAAP template 2.8" (7.1 cm) 7.9" (20.1 cm) SURFACE CUT-OUT AREA FOR FURNITURE MOUNT 10" (25.4 cm) Cut-Out Template for

© 2007 Extron Electronics. All rights reserved.

Extron Electronics, USA1230 South Lewis StreetAnaheim, CA 92805800.633.9876 714.491.1500 FAX 714.491.1517

Extron Electronics, EuropeBeeldschermweg 6C3821 AH Amersfoort, The Netherlands+800.3987.6673 +31.33.453.4040FAX +31.33.453.4050

Extron Electronics, JapanKyodo Building, 16 IchibanchoChiyoda-ku, Tokyo 102-0082Japan+81.3.3511.7655 FAX +81.3.3511.7656

Extron Electronics, Asia135 Joo Seng Rd. #04-01PM Industrial Bldg., Singapore 368363+800.7339.8766 +65.6383.4400 FAX +65.6383.4664www.extron.com